For 32426,32427,32428 and 32429 (+G) - 1 - REWORK OF COMPRESSOR FROM EXTERNALLY TO INTERNALLY REGULATED FOR OPEL ASTRA H In case of replacement the compressor of AC system has to be replaced by an internally regulated compressor, install a cable bridge abd an additional cable. Use the actually circuit diagram to rework the electrical system. Working procedure: 1. Disconnect battery. 2. Replace compressor. 3. Remove engine compartment electronic module (UEC). 4. Clip-off wiring harness plug XE2.
7
Embed
REWORK OF COMPRESSOR FROM EXTERNALLY TO INTERNALLY ...
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
For 32426,32427,32428 and 32429 (+G)
- 1 -
REWORK OF COMPRESSOR FROM EXTERNALLY TO INTERNALLY REGULATED FOR OPEL ASTRA H
In case of replacement the compressor of AC system has to be replaced by an internally regulated compressor, install a cable bridge abd an additional cable. Use the actually circuit diagram to rework the electrical system. Working procedure: 1. Disconnect battery.
If a cable bridge is installed between chamber 52 and chamber 53, go on as of step 8.
6. Install cable bridge into wiring harness plug XE2 (Picture 1). unlatch protection in direction of arrow remove seals with a suitable tool install cable bridge brown/black into chamber 52 terminal with grey seal and chamber 53
unlatch protection in direction of arrow remove seal with a suitable tool install terminal (female) into chamber 44, pay attention to installation position
latch wiring harness plug.
10. Clip-in wiring harness plug XE1.
11. Route cable along the wiring harness to plug X26 and fasten with insulating tape.
12. Remove front wheel.
13. Remove wheel housing protective paneling.
14. Clip-off wiring harness plug X26 from bracket.
15. Unlatch and disconnect wiring harness plug X26 (Picture 3)
Picture 2
For 32426,32427,32428 and 32429 (+G)
- 4 -
remove cable strap remove lock latching (1)
16. Remove terminals from chamber 1 and chamber 2 (Picture 4)
press out terminals cut-off terminals
insulate cable ends and fasten to wiring harness with insulating tape.
Picture 3
Picture 4
For 32426,32427,32428 and 32429 (+G)
- 5 -
17. Install terminal of cable black/white from wiring harness plug XE1 (chamber 44) into wiring
harness plug X26 as well as terminal of brown cable and install lock latching (Picture 5).