*29133068_0719* Drive Technology \ Drive Automation \ System Integration \ Services Revision Decentralized Drive Systems MOVIMOT ® MM..D Edition 07/2019 29133068/EN
*29133068_0719*Drive Technology \ Drive Automation \ System Integration \ Services
Revision
Decentralized Drive SystemsMOVIMOT® MM..D
Edition 07/2019 29133068/EN
SEW-EURODRIVE—Driving the world
1Revision
Revision – MOVIMOT® MM..D 3
1 RevisionThis revision applies to the following documentations:
"MOVIMOT® MM..D" operating instructions, part number 21214190/EN, edition10/2014
Replacements • Chapter 3.5.1 "Nameplate" is replaced by "Nameplate" (→ 2 4).• Chapter 5.7.11 "Connection of forced cooling fan V" is replaced by "Connection of
forced cooling fan V" (→ 2 5).• Chapter 6.5.3 "DIP switch S1/6" > "Motor with 50/60 Hz voltage range" is replaced
by "Motor with 50/60 Hz voltage range" (→ 2 8).• Chapter 11.13 "Assignment of the drive ID module" is replaced by "Assignment of
the drive ID module" (→ 2 12).• Chapter 12.1.2 "Short circuit current rating" is replaced by "Short circuit current rat-
ing" (→ 2 13).• Chapter 13 "Declaration of conformity" replaced by"Declaration of conform-
ity" (→ 2 15).Supplements • Chapter 4.6 "Mechanical installation" > "Installation of the MOVIMOT® inverter
close to the motor", is supplemented by subchapter "Mounting posi-tion" (→ 2 4).
• Chapter 9 "Operation" is supplemented by subchapter "Operatingnotes" (→ 2 11).
• Chapter 10.3 "Inspection/maintenance" is supplemented by subchapter "Re-pairs" (→ 2 12).
"MOVIMOT® MM..D" compact operating instructions, part number 21326592/EN,edition 10/2014
Replacements • Chapter 3.3.1 "Nameplate" is replaced by "Nameplate" (→ 2 4).• Chapter 6.3.3 "DIP switch S1/6" > "Motor with 50/60 Hz voltage range" is replaced
by "Motor with 50/60 Hz voltage range" (→ 2 8).• Chapter 9 "Declaration of conformity" replaced by"Declaration of conform-
ity" (→ 2 15).Supplements • Chapter 4.5 "Installation of the MOVIMOT® inverter close to the motor", is supple-
mented by subchapter "Mounting position" (→ 2 4).
2913
3068
/EN
– 0
7/20
19
1 RevisionNameplate
Revision – MOVIMOT® MM..D4
1.1 Nameplate
Order-specificnameplate
The following figure provides an example of an order-specific nameplate of theMOVIMOT® inverter for mounting close to the motor:
P-Motor = 1,5kW95.7416041003.0001.17S0#:
/APG4 IP65 ML 0001MM15D-503-00/0/P21A/RO1AType:
U= 3x380...500V I= 3,5A ACInput:
Made in GermanyFeldverteiler
Field Distributor
01UL®
LISTEDIND.CONT.EQ.
2D06
C US
General name-plate
The following figure provides an example of a general nameplate of the MOVIMOT®
inverter for mounting close to the motor:
Input:
Input:
Output to next Field Distributor:
Output to drive:
3x200...500VU=–Imax= Imax=
3x200...500V
50...60Hz
U=
f=1,3...3,5A ACImax=
–U=–
3x0...Uinput
0,25...1,5kW
U=
P-Motor=1,6...4,0A ACImax=
1.2 Mounting positionInstall the MOVIMOT® inverter MM40D (4 kW) in mounting position M2 (heat sink onbottom, see right figure) close to the motor only if ambient temperatures are ϑa ≤35 °C.
MM40D
ϑu ≤ 35 °C
20870741899
2913
3068
/EN
– 0
7/20
19
1RevisionConnection of forced cooling fan V
Revision – MOVIMOT® MM..D 5
1.3 Connection of forced cooling fan V
The AC motors in the DR.. series are also available with the forced cooling fan V. Us-ing the forced cooling fan V extends the setting range of the setpoint speed. Thismeans that speeds from 150 min-1 (5 Hz) can be realized continuously.
INFORMATION• For motors with V forced cooling fans, the P341 type of cooling parameter must
be set to "forced air cooling".• When using MOVIMOT® drives with functional safety (STO), do not connect the
forced cooling fan to the connection box. Instead, use an external DC 24 V supplyto supply the forced cooling fan with power.
The following figure shows the cable routing of the forced cooling fan cable forMOVIMOT® drives (without functional safety):
18014401679145483
The following figure shows an example connection for the V forced cooling fan (onlyfor MOVIMOT® drives without functional safety):
MOVIMOT®
DC 24 V
X1
: 1
3
X1
: 1
4
X1
: 1
5
24
V X
6: 1
,2,3
X6
: 4
,5,6
RX
6: 1
1,1
2
LX
6: 9
,10
X6
: 7
,8
X5
: 2
5,2
6
X5
: 2
7,2
8
X5
: 2
9,3
0
X5
: 3
1,3
2
f1/f2
K1
a
K1
b
RS
-
RS
+
X1
: L
1
X1
: L
2
X1
: L
3
24 V
RD
BU
9007202436852107
2913
3068
/EN
– 0
7/20
19
1 RevisionMotor with operating point 400 V/50 Hz
Revision – MOVIMOT® MM..D6
1.4 Motor with operating point 400 V/50 HzApplies to MOVIMOT® with the following drive ID modules:
Drive ID module MotorIdentification Identification
colorPart number Line voltage
VLine frequency
HzDR2S/400/50 Light gray/white
striped28249720 230/400 50
DRS/400/50 White 18214371 230/400 50DRE/400/50 Orange 18214398 230/400 50
DRP/230/400 Brown 18217907 230/400 50DRN/400/50 Light blue 28222040 230/400 50
Setting of DIP switch S1/6:Power rating Motor type MOVIMOT® inverter MM..D-503-00
Motor in W connection Motor in m connectionkW S1/6 = OFF S1/6 = ON S1/6 = OFF S1/6 = ON
0.25DR2S63M4/..DR63L4/..DRE80S4/..DRN71MS4
– MM03D.. MM03D.. MM05D..
0.37DR2S71MS4/..DRS71S4/..DRE80S4/..DRN71M4
MM03D.. MM05D.. MM05D.. MM07D..
0.55DR2S71M4/..DRS71M4/..DRE80M4/..DRN80MK4
MM05D.. MM07D.. MM07D.. MM11D..
0.75
DR2S80MK4/..DRS80S4/..DRE80M4/..DRP90M4/..DRN80M4/..
MM07D.. MM11D.. MM11D.. MM15D..
1.1
DR2S80M4/..DRS80M4/..DRE90M4/..DRP90L4/..DRN90S4/..
MM11D.. MM15D.. MM15D.. MM22D..
1.5DRS90M4/..DRE90L4/..DRP100M4/..DRN90L4/..
MM15D.. MM22D.. MM22D.. MM30D..
2.2DRS90L4/..DRE100M4/..DRP100L4/..DRN100LS4/..
MM22D.. MM30D.. MM30D.. MM40D..
3.0DRS100M4/..DRE100LC4/..DRP112M4/..DRN100L4/..
MM30D.. MM40D.. MM40D.. –
4.0DRS100LC4/..DRE132S4/..DRN112M4/..
MM40D.. – – –
2913
3068
/EN
– 0
7/20
19
1RevisionMotor with operating point 460 V/60 Hz
Revision – MOVIMOT® MM..D 7
1.5 Motor with operating point 460 V/60 HzApplies to MOVIMOT® with the following drive ID modules:
Drive ID module MotorIdentification Identification
colorPart number Line voltage
VLine frequency
HzDR2S/460/60 Yellow/white
striped28249739 266/460 60
DRS/460/60 Yellow 18214401 266/460 60DRE/460/60 Green 18214428 266/460 60
DRP/266/460 Beige 18217915 266/460 60DRN/460/60 Blue/white striped 28241819 266/460 60
Setting of DIP switch S1/6:Power rating Motor type MOVIMOT® inverter MM..D-503-00
Motor in W connection Motor in m connectionkW S1/6 = OFF S1/6 = ON S1/6 = OFF S1/6 = ON
0.25 DR2S63M4/..DRN71MS4/.. – MM03D.. MM03D.. MM05D..
0.37DR2S71MS4/..DRS71S4/..DRN71M4/..
MM03D.. MM05D.. MM05D.. MM07D..
0.55DR2S71M4/..DRS71M4/..DRN80MK4/..
MM05D.. MM07D.. MM07D.. MM11D..
0.75
DR2S80MK4/..DRS80S4/..DRE80M4/..DRP90M4/..DRN80M4/..
MM07D.. MM11D.. MM11D.. MM15D..
1.1
DR2S80M4/..DRS80M4/..DRE90M4/..DRP90L4/..DRN90S4/..
MM11D.. MM15D.. MM15D.. MM22D..
1.5DRS90M4/..DRE90L4/..DRP90L4/..DRN90L4/..
MM15D.. MM22D.. MM22D.. MM30D..
2.2DRS90L4/..DRE100L4/..DRP112M4/..DRN100L4/..
MM22D.. MM30D.. MM30D.. MM40D..
3.7DRS100M4/..DRE100LC4/..DRP132S4/..DRN100L4/..
MM30D.. MM40D.. – –
4.0DRS100LC4/..DRE132S4/..DRN112M4/..
MM40D.. – – –
2913
3068
/EN
– 0
7/20
19
1 RevisionMotor with 50/60 Hz voltage range
Revision – MOVIMOT® MM..D8
1.6 Motor with 50/60 Hz voltage range
Applies to MOVIMOT® with the following drive ID modules:
Drive ID module MotorIdentification Identification
colorPart number Line voltage V Line fre-
quency Hz
DRS/DRE/50/60 Violet 18214444
220 – 240/50
380 – 415
254 – 277/60
440 – 480
DRS/DRN/50/60 Pastel green 28241827
220 – 230/50
380 – 400
266/460 60
DRN/50/60 Purple/whitestriped 28249747
220 – 230/50
380 – 400
266/460 60
Setting of DIP switch S1/6:
Powerrating
Motor type MOVIMOT® MM..D-503-00 inverter
kW Motor in W connection Motor in m connectionS1/6 = OFF S1/6 = ON S1/6 = OFF S1/6 = ON
0.25DR63L4/..DRN71MS4/..
– MM03D.. MM03D.. MM05D..
0.37DRS71S4/..DRN71M4/..
MM03D.. MM05D.. MM05D.. MM07D..
0.55DRS71M4/..DRN80MK4/..
MM05D.. MM07D.. MM07D.. MM11D..
0.75DRE80M4/..DRN80M4/..
MM07D.. MM11D.. MM11D.. MM15D..
1.1DRE90M4/..DRN90S4/..
MM11D.. MM15D.. MM15D.. MM22D..
1.5DRE90L4/..DRN90L4/..
MM15D.. MM22D.. MM22D.. MM30D..
2.2DRE100L4/..DRN100LM4/..
MM22D.. MM30D.. MM30D.. MM40D..
3.0DRE100LC4/..DRN100L4/..
MM30D.. MM40D.. MM40D.. –
2913
3068
/EN
– 0
7/20
19
1RevisionMotor with operating point 380 V/60 Hz (ABNT regulation for Brazil)
Revision – MOVIMOT® MM..D 9
Powerrating
Motor type MOVIMOT® MM..D-503-00 inverter
kW Motor in W connection Motor in m connectionS1/6 = OFF S1/6 = ON S1/6 = OFF S1/6 = ON
4.0DRE132S4/..DRN112M4/..
MM40D.. – – –
1.7 Motor with operating point 380 V/60 Hz (ABNT regulation for Brazil)Applies to MOVIMOT® with the following drive ID modules:
Drive ID module MotorIdentification Identification
colorPart number Line voltage
VLine frequency
HzDRS/DRE/380/60 Red 18234933 220/380 60
DRN/380/60 Red/white striped 28240227 220/380 60
Setting of DIP switch S1/6:Power rating Motor type MOVIMOT® inverter MM..D-503-00
Motor in W connection Motor in m connectionkW S1/6 = OFF S1/6 = ON S1/6 = OFF S1/6 = ON0.25 DRN71MS4/.. – MM03D.. MM03D.. MM05D..
0.37 DRS71S4/..DRN71M4/.. MM03D.. MM05D.. MM05D.. MM07D..
0.55 DRS71M4/..DRN80MK4/.. MM05D.. MM07D.. MM07D.. MM11D..
0.75 DRE80S4/..DRN80M4/.. MM07D.. MM11D.. MM11D.. MM15D..
1.1 DRE80M4/..DRN90S4/.. MM11D.. MM15D.. MM15D.. MM22D..
1.5 DRE90M4/..DRN90L4/.. MM15D.. MM22D.. MM22D.. MM30D..
2.2 DRE90L4/..DRN100LM4/.. MM22D.. MM30D.. MM30D.. MM40D..
3.0 DRE100M4/..DRN100L4/.. MM30D.. MM40D.. MM40D.. –
4.0 DRE100L4/..DRN100L4/.. MM40D.. – – –
1.8 Motor with operating point 400 V/50 Hz and LSPM technologyApplies to MOVIMOT® with the following drive ID modules:
Drive ID module MotorIdentification Identification
colorPart number Line voltage [V] Line frequency
[Hz]DRE...J/400/50 Orange 28203816 230/400 50DRU...J/400/50 Gray 28203194 230/400 50
Setting of DIP switch S1/6:Power rating Motor type MOVIMOT® inverter MM..D-503-00
Motor in W connection Motor in m connection[kW] S1/6 = OFF S1/6 = ON S1/6 = OFF S1/6 = ON0.25 DRU71SJ/.. – MM03D.. MM03D.. MM05D..
0.37 DRE71SJ4/..DRU71MJ4/.. MM03D.. MM05D.. MM05D.. MM07D..
2913
3068
/EN
– 0
7/20
19
1 RevisionDIP switch S2/1
Revision – MOVIMOT® MM..D10
Power rating Motor type MOVIMOT® inverter MM..D-503-00Motor in W connection Motor in m connection
[kW] S1/6 = OFF S1/6 = ON S1/6 = OFF S1/6 = ON
0.55 DRE71MJ4/..DRU80SJ4/.. MM05D.. MM07D.. MM07D.. MM11D..
0.75 DRE71MJ4/..DRU80MJ4/.. MM07D.. MM11D.. MM11D.. MM15D..
1.1 DRE80SJ4/..DRU90MJ4/.. MM11D.. MM15D.. MM15D.. MM22D..
1.5 DRE80MJ4/..DRU90LJ4/.. MM15D.. MM22D.. MM22D.. MM30D..
2.2 DRE90MJ4/..DRU100MJ4/.. MM22D.. MM30D.. MM30D.. MM40D..
3.0 DRE90LJ4/..DRU100LJ4/.. MM30D.. MM40D.. MM40D.. –
4.0 DRE100MJ4/.. MM40D.. – – –
1.9 DIP switch S2/1Brake type• When using the standard brake, the DIP switch S2/1 must be set to "OFF".• When using the optional brake, the DIP switch S2/1 must be set to "ON".
Motor Standard brake [type]
Optional brake [type]
400 V/50 Hz460 V/60 Hz
50/60 Hz voltage range
380 V/60 HzABNTBrazil
400 V/50 HzLSPM
Technology
S2/1 = OFF S2/1 = ON
DR63L4 BR03 –DR2S63M4 BE03 BE03
DRN71MS4 DRN71MS4 BE03 BE05DRS71S4DRE80S4
DR2S71MS4DRN71M4DRN71MK4
DRS71S4DRN71M4
DRE71SJ4DRU71SJ4DRU71MJ4
BE05 BE1
DRS71M4DRS80S4DRE80M4
DR2S71M4DR2S80MK4DRN80MK4DRN80M4
DRS71M4DRE80S4DRN80MK4DRN80M4
DRE71MJ4DRU80SJ4
BE1 BE05
DRP90M4 DRU80MJ4 BE1 BE2DRS80M4DRE90M4DRP90L4
DR2S80M4DRN90S4
DRE80M4DRN90S4
DRE80SJ4DRU90MJ4
BE2 BE1
DRS90M4DRE90L4
DRN90L4 DRE90M4DRN90L4
DRE80MJ4 BE2 BE1
DRP100M4 DRU90LJ4 BE2 BE5DRS90L4DRE100M4DRE100L4DRP100L4
DRN100LS4 DRE90L4 DRE90MJ4DRE90LJ4DRU100MJ4
BE5 BE2
DRS100M4DRS100L4DRS100LC4DRE100LC4
DRN100L4DRN100LM4
DRE100M4DRE100L4DRN100L4DRN100LM4
DRE100MJ4DRU100LJ4
BE5 BE2
DRP112M4DRE132S4DRP112S4
DRN112M4 BE5 BE11
Preferred brake voltageMOVIMOT® type (inverter) Preferred
brake voltageMOVIMOT® MM..D-503, size 1 (MM03.. – MM15..) 230 V
2913
3068
/EN
– 0
7/20
19
1RevisionOperating notes
Revision – MOVIMOT® MM..D 11
MOVIMOT® type (inverter) Preferredbrake voltage
MOVIMOT® MM..D-503, size 2 (MM22.. – MM40..)120 V
MOVIMOT® MM..D-233, sizes 1 and 2 (MM03.. – MM22..)
1.10 Operating notes
WARNINGElectric shock caused by dangerous voltages at the connections, cables and motorterminals.When the device is switched on, dangerous voltages are present at the connectionsas well as at any connected cables and motor terminals. This also applies evenwhen the device is inhibited and the motor is at standstill.Severe or fatal injuries.• Do not switch under load.• Before performing any work on the device, disconnect it from the voltage supply.
Note that dangerous voltages can occur at the terminals and connections for upto 1 minute after the controller is switched off.
• Block the output stage of the inverter before switching at the output of the device.
WARNINGElectric shock from capacitors that have not been fully discharged.Severe or fatal injuries.• Disconnect the inverter from the power. Observe the minimum switch-off time
after disconnection from the supply system:– 1 minute
WARNINGRisk of crushing if the motor starts up unintentionally.Severe or fatal injuries• Observe the startup instructions.• Deactivate all control signals.
WARNINGDanger of burns due to hot surfaces of the device (e.g. the heat sink).Serious injuries.• Do not touch the device until it has cooled down sufficiently.
INFORMATION• The maximum output frequency in any operating mode is 120 Hz.• If the maximum output frequency is exceeded, the status LED of the MOVIMOT®
inverter flashes slowly red (error 08 "speed monitoring").
2913
3068
/EN
– 0
7/20
19
1 RevisionRepairs
Revision – MOVIMOT® MM..D12
1.11 RepairsOnly SEW-EURODRIVE is authorized to carry out repairs.
1.12 Assignment of the drive ID module
Motor Drive ID moduleType Line voltage Line fre-
quencyIdentification Identifica-
tion colorPart number
V HzDR2S.. 230/400 50 DR2S/400/50 Light gray/
white striped
28249720
DR2S.. 266/460 60 DR2S/460/601) Yellow/white striped
28249739
DRS.. 230/400 50 DRS/400/50 White 18214371
DRE.. 230/400 50 DRE/400/50 Orange 18214398
DRS.. 266/460 60 DRS/460/601) Yellow 18214401
DRE.. 266/460 60 DRE/460/601) Green 18214428
DRS../DRE.. 220/380 60 DRS/DRE/380/601) Red 18234933
DRS../DRE.. 220 – 240/380 – 415254 – 277/440 – 480
5060
DRS/DRE/50/60 Violet 18214444
DRE...J.. 230/400 50 DRE...J/400/50 Orange 28203816
DRU...J.. 230/400 50 DRU...J/400/50 Gray 28203194
DRN.. 220/380 60 DRN/380/601) Red/whitestriped
28240227
DRN.. 230/400 50 DRN/400/50 Light blue 28222040
DRN.. 266/460 60 DRN/460/601) Blue/whitestriped
28241819
DRS../DRN.. 220 – 230/380 – 400266/460
5060
DRS/DRN/50/60 Green/white
striped
28241827
DRN.. 220 – 230/380 – 400266/460
5060
DRN/50/60 Purple/white striped
28249747
1) This drive ID module can also be combined with MOVIMOT® MM..D-233.
2913
3068
/EN
– 0
7/20
19
1RevisionAppendix
Revision – MOVIMOT® MM..D 13
1.13 Appendix
INFORMATIONDue to UL requirements, the following chapters are always printed in English inde-pendent of the language of the publication:
1.13.1 UL-compliant installation
Field wiring power terminalsObserve the following notes for UL-compliant installation:• Use 60/75 °C copper wire only• Tighten terminals to 1.5 Nm (13.3 in-lb.)
Short circuit current ratingSuitable for use on a circuit capable of delivering not more than 200,000 rms symmet-rical amperes when protected as follows:
For 240V systems:250V minimum, 25A maximum non-semiconductor fuses or250V minimum, 25A maximum inverse time circuit breakers
For 500V systems:500V minimum, 25A maximum, non-semiconductor fuses or500V minimum, 25A maximum, inverse time circuit breakersThe max. voltage is limited to 500 V.
Group installation
All models rated 5 kA for group installation when protected as follows:
For 240V systems:240V minimum, 25A maximum non-semiconductor fuses or240V minimum, 25A maximum inverse time circuit breaker.
For 500V systems:500V minimum, 25A maximum, non-semiconductor fuses or500V minimum, 25A maximum, inverse time circuit breakers.
All models rated 18 kA for group installation when protected as follows:
For 240V systems:240V minimum, 25A maximum non-semiconductor fuses
For 500 V systems:500V minimum, 25A maximum, non-semiconductor fuses
2913
3068
/EN
– 0
7/20
19
1 RevisionAppendix
Revision – MOVIMOT® MM..D14
Branch circuit protectionIntegral solid state short circuit protection does not provide branch circuit protection.Branch circuit protection must be provided in accordance with the National ElectricalCode and any additional local codes.For maximum branch circuit protection see table below.
Series non-semiconductor fuses inverse time circuit breakerMOVIMOT® MM..D 250 V/500 V minimum, 25 A
maximum250 V/500 V minimum, 25 A
maximum
Motor overload protectionMOVIMOT® MM..D is provided with load and speed-sensitive overload protection andthermal memory retention upon shutdown or power loss.The trip current is adjusted to 140 % of the rated motor current.
Ambient temperatureMOVIMOT® MM..D is suitable for an ambient temperature of 40 °C, max. 60 °C withderated output current. To determine the output current rating at higher than 40 °C,the output current should be derated 3.0 % per °C between 40 °C and 60 °C.• Only use certified units with a limited output voltage (Vmax = DC 30 V) and limited
output current (I ≤ 8 A) as an external DC 24 V voltage source.• The UL certification only applies for the operation on voltage supply systems with
voltages to ground of max. 300 V. The UL-certification does not apply to operationon voltage supply systems with a non-grounded star point (IT systems).
2913
3068
/EN
– 0
7/20
19
1RevisionDeclaration of conformity
Revision – MOVIMOT® MM..D 15
1.14 Declaration of conformity
EU Declaration of ConformityTranslation of the original text 900030410/EN
SEW-EURODRIVE GmbH & Co. KGErnst-Blickle-Straße 42, D-76646 Bruchsaldeclares under sole responsibility that the following products
Bruchsal
a) Authorized representative for issuing this declaration on behalf of the manufacturerb) Authorized representative for compiling the technical documents
Place Date
20.07.2017
Managing Director TechnologyJohann Soder
a) b)
Frequency inverters of the product family MOVIMOT® MM..D-..3-..MOVIMOT® .../MM../...
in accordance with
Machinery Directive 2006/42/EC(L 157, 09.06.2006, 24-86)
This includes the fulfillment of the protection targets for "electrical power supply" in accordance with annex I No. 1.5.1according to the Low Voltage Directive 73/23/EEC -- Note: 2014/35/EU is currently valid.
EMC Directive 2014/30/EU 4)(L 96, March 29, 2014, 79-106)
RoHS Directive 2011/65/EU(L 174, July 1, 2011, 88-110)
Applied harmonized standards: EN ISO 13849-1:2008/AC:2009EN 61800-5-2:2007EN 61800-5-1:2007EN 61800-3:2004/A1:2012EN 50581:2012
4) According to the EMC Directive, the listed products are not independently operable products. EMC assessment is only possibleafter these products have been integrated in an overall system. For the assessment, the product was installed in a typical plantconfiguration.
2913
3068
/EN
– 0
7/20
19
SEW-EURODRIVE—Driving the world
SEW-EURODRIVE GmbH & Co KGErnst-Blickle-Str. 4276646 BRUCHSALGERMANYTel. +49 7251 75-0Fax +49 7251 [email protected]