Michael Pacholok, Acting Director Purchasing & Materials Management City Hall, 18th Floor, West 100 Queen Street West Toronto, Ontario M5H 2N2 Victor Tryl , Manager Professional Services February 23, 2012 Via Email – 8 Pages ADDENDUM NO. 4 TENDER CALL NO. 29-2012 CONTRACT NO. 12FS-01WP FOR: REPLACEMENT OF BYPASS STACK CAPPING DAMPER HIGHLAND CREEK TREATMENT PLANT CLOSING DATE: 12:00 NOON, LOCAL TIME FRIDAY, MARCH 2, 2012 Please refer to the above Request for Tender (RFT) document in your possession and be advised of the following information. REVISION: A4-1: SECTION 4 – SCOPE OF WORK TECHNICAL SPECIFICATIONS SECTION 02070 – Demolition, Item 1.1.E.1 The referenced clause is to be replaced in its entirety with the following: 1. The breeching duct is constructed of steel and is lined with 115 mm light weight castable refractory, an insulating board and loosely packed glass fiber insulation. The demolition must be completed in limited space and includes rerouting of cables, pipes and other equipment. Reference drawing A-23511 (enclosed) shows the original installation of the breeching duct and the roof support design loading schedule. Note that the duct was extended to the south in 1987. A4-2: SECTION 15200 – Process Piping Systems, Item 2.3.E.3 The referenced clause is to be replaced in its entirety with the following: 3. The safety relief valve shall be set for 862 kPa (125 psig) and shall pass full flow (425 Nm 3 /hr or 250 scfm) to maintain the pressure below 948 kPa (137.5 psig) A4-3: SECTION 15200 – Process Piping Systems, Item 2.3.F Add the following to the referenced clause: F. …and a maximum allowable working pressure (MAWP) of at least 1034 kPa (150 psig).
8

REVISION: A4-1: SECTION 4 – SCOPE OF WORK ...

May 12, 2023

Download

Documents

Khang Minh
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: REVISION: A4-1: SECTION 4 – SCOPE OF WORK ...

Michael Pacholok, Acting Director Purchasing & Materials Management City Hall, 18th Floor, West 100 Queen Street West Toronto, Ontario M5H 2N2

Victor Tryl , ManagerProfessional Services

February 23, 2012 Via Email – 8 Pages

ADDENDUM NO. 4

TENDER CALL NO. 29-2012 CONTRACT NO. 12FS-01WP

FOR: REPLACEMENT OF BYPASS STACK CAPPING DAMPER

HIGHLAND CREEK TREATMENT PLANT

CLOSING DATE: 12:00 NOON, LOCAL TIME FRIDAY, MARCH 2, 2012

Please refer to the above Request for Tender (RFT) document in your possession and be advised of the following information. REVISION: A4-1: SECTION 4 – SCOPE OF WORK TECHNICAL SPECIFICATIONS SECTION 02070 – Demolition, Item 1.1.E.1

The referenced clause is to be replaced in its entirety with the following: 1. The breeching duct is constructed of steel and is lined with 115 mm light weight castable

refractory, an insulating board and loosely packed glass fiber insulation. The demolition must be completed in limited space and includes rerouting of cables, pipes and other equipment. Reference drawing A-23511 (enclosed) shows the original installation of the breeching duct and the roof support design loading schedule. Note that the duct was extended to the south in 1987.

A4-2: SECTION 15200 – Process Piping Systems, Item 2.3.E.3

The referenced clause is to be replaced in its entirety with the following: 3. The safety relief valve shall be set for 862 kPa (125 psig) and shall pass full flow (425 Nm3/hr

or 250 scfm) to maintain the pressure below 948 kPa (137.5 psig) A4-3: SECTION 15200 – Process Piping Systems, Item 2.3.F

Add the following to the referenced clause: F. …and a maximum allowable working pressure (MAWP) of at least 1034 kPa (150 psig).

Page 2: REVISION: A4-1: SECTION 4 – SCOPE OF WORK ...

- 2 -

Questions and Answers Q1. Please provide drawings & specs for existing ID Fans to be inspected. A1. The original fan was supplied in the 1976 by Sheldons Engineering Limited of Cambridge, Ontario

(refer to Drawing C-18581-3). Contact info: Sheldons Engineering Inc. 6660 Ordan Drive Mississauga, Ontario Canada L5T 1J7 1-800-265-3572 In the 1987, the fan was overhauled by Novenco Canada Inc. of Cambridge, Ontario (refer to Drawing ND-11478). Novenco was later purchased by Howden.

During the preparation of this contract, we contacted Howden North America to inquire if they had service personnel who could perform a portion of the inspection work associated with the fans. Contact info is: Gary Kaiser Howden North America 1775 Wehrle Dr. Williamsville, NY 14221 716-817-6958 [email protected]

Q2. Please provide CFM and pressure ratings for safety valves on air receiver tanks. A2. Please refer to A4-2 and A4-3 above Q3. Please provide drawings of existing stacks and ducting, including flange drawings, and weight of

existing stack. A3. Drawings from the original bypass stack installation (Drawings 5600-10 and 5600-11) are enclosed.

The as-built condition of the stacks may differ. It is our understanding that the existing stacks were constructed of 3/16” thick 316L SS. Contractor to verify on site.

Q4. Please advise if existing stacks have refractory inside, if so, what type. A4. The existing stub stack is not refractory lined. Q6. Please provide name and contact information of ID fan manufacturer for inspection requirements. A6. The names and contact information for the ID fan manufacturers are noted above in Q1. The

inspection requirements are noted in the specifications (Section 13425).  

Page 3: REVISION: A4-1: SECTION 4 – SCOPE OF WORK ...

- 3 -

Should you have any questions regarding this addendum contact Allison Phillips at 416-397-4825 or email [email protected]. Please attach this addendum to your RFT document and be governed accordingly. Tenderers are to acknowledge receipt of all addenda in their Tender in the space provided in the Tender Call Cover Page of the RFT document. All other aspects of the RFT remain the same.

End of Addendum No. 4

Yours truly, Victor Tryl, P.Eng Manager Professional Services Purchasing and Materials Management