Top Banner
GENERAL CATALOGUE DELPHI SERIES 04 09 REV.0 GENERAL CATALOGUE DELPHI SERIES ASYNCHRONOUS THREE-PHASE ELECTRIC MOTORS ®
28

REV.0 GENERAL CATALOGUE - Emco Engineers

Oct 16, 2021

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: REV.0 GENERAL CATALOGUE - Emco Engineers

GEN

ERAL

CATA

LOG

UE

DEL

PH

I SER

IES 0

4 0

9 R

EV.0

G E N E R A L C A T A L O G U EDELPHI SERIES ASYNCHRONOUS THREE-PHASE ELECTRIC MOTORS

®

Page 2: REV.0 GENERAL CATALOGUE - Emco Engineers
Page 3: REV.0 GENERAL CATALOGUE - Emco Engineers

®

INDEX

Technical characteristics pag. 4-5

Efficiency pag. 6CE Marking pag. 7Delphi EX

Protection TypeDuty Service pag. 8Working conditions pag. 9Assisted power cooling

Motive motors protection pag. 10

Three-phase self-brakingmotors series atdc delphi pag. 11

Delphi ATDC pag. 12

Brake description pag. 13Brake operationAdjustment

Wiring diagrams pag. 14

Motor configurations and pag. 15installation positions

Table of dimensions pag. 16-17

Technical data pag. 18-19

Technical data pag. 20-21

Technical data pag. 22-23

Component list pag. 24

Rubber seal ringsand bearings pag. 25

Terms of saleand guarantee pag. 26

Page 4: REV.0 GENERAL CATALOGUE - Emco Engineers

4

TECHNICAL CHARACTERISTICS

Motive motors are built according tointernational standard regulations; eachsize throughout the construction formsis calculated with reference to the tablesof standard IEC 72-1.

The shapes built per IEC 34-7, are B3,B5, B14, B35.

Motive asynchronous three-phase Delphiseries motors are closed, and externallyventilated.The frame, up to 132 included, is madein die casting aluminium alloy, from size160 up to 355 the frame is made in castiron.

All motors aremultiple voltagemulti-frequency 50/60Hz,F class insulation,S1 continuous duty service,IP55 protection1 or 2 efficiency classtropicalized.

motive motors adopt only bearings selected fortheir silence and reliability and, for the sameobjectives, the cage rotor is dynamically balancedaccording to IEC 34-14 and ISO 9921 norms

Blocking the bearings intotheir slots with snap ringsprevents them frommoving axially. From type90, a steel insert isprovided in the bearing slotof the aluminum flanges,to res is t to rad ia lmechanical forces with afair degree of security

The copper is impregnated with adouble layer of H class insulatingenamel to ensure high resistanceto e lectr ica l , thermal andmechanical stress.The phases are further isolated byanother layer of Nomex film toprotect the motors from the voltagepeaks that usually occur when themotor is controlled by an inverter.

PATENTED

Page 5: REV.0 GENERAL CATALOGUE - Emco Engineers

5

Aiming the maximumprotection, the motorsare equipped withimportant details like thepull-resistant cable pressand the combination ofbearings with two shieldseach with rubber sealrings

Performance excellence is granted by theFeV magnetic lamination sheets adoption,instead then the usual normal FeP01,FeV lamination sheets provide higherefficiency, lower heating, energy savingand longer life to isolation materials

To protect them by the rust,motive motors are painted ins i l ver RAL9006 colour

Feet and connectionbox can be movedto the right or left

Cable press can beeasily moved on both thesides of the connectionbox, thanks to the screwcap

the connectionbox can berotated of 360°with steps of 90°

Page 6: REV.0 GENERAL CATALOGUE - Emco Engineers

70

75

80

85

90

95

1 10 100

PN/kW

%

ηN

4 p

2 p

6

There are no requestsabout minimum efficiency,but it is defined clearlywhich are the motorsclassified efficiency 1, 2and 3.Motive has organized itsproduction respecting theparameters indicated bythe new Europeanclassification.Client’s benefits are ofmany kinds

The European Agreement issued by the European Commission and CEMEP (European Committee of Manufacturers of Electrical Machines and Power Electronics), establishes a newclassification system of electric motors based on the efficiency. The reference values are shown by the attached diagram and the following paragraph.

EFFICIENCY

BILL EFFECTSBill effects are the first to be inevidence. The calculation changesd e p e n d i n g b y t h e u s ecircumstances, but we can saythat efficiency 2 motors allow asaving of about 20%. For instance,a 15kW motor, for an operationperiod of 6.000 hours per year,can save about 2 MWh/a ormore: about 100 Euro of yearlyoperation costs

DURABILITY EFFECTSHigher efficiency motors heat less,slowing down the aging cycle of theinsulating materials and living longer.Average operating life of Eff.2 Motivemotors is:2500 hours/ year for motors upto 15kW4000 hours/year for bigger motorsThe average life is approximatelyfrom 25 to 30.000 hours for thefirst and 50,000 for the secondones

AMBIENT EFFECTSEfficiency 2 motors guaranteegreat energy and money savings,with an objective of sustainabledevelopment, reduction of CO2emissions and consequentimprovement of the quality of theatmosphere

HOW TO MAKE A MORE EFFICIENTMOTOR?High efficiency can be seen in manyways: like the relation betweenoutput power and input absorbedpower, or like a measure of thelosses that born when convertingthe electric power in mechanicalenergy.From another perspective, highefficiency motors consume lessenergy to produce the same torque

Motors 2 poles

kWefficiency

eff3 eff2 eff1

1.1 <76.2 ≥76.2 >82.8

1.5 <78.5 ≥78.5 >84.1

2.2 <81.0 ≥81.0 >85.6

3 <82.6 ≥82.6 >86.7

4 <84.2 ≥84.2 >87.6

5.5 <85.7 ≥85.7 >88.6

7.5 <87.0 ≥87.0 >89.5

11 <88.4 ≥88.4 >90.5

15 <89.4 ≥89.4 >91.3

18.5 <90.0 ≥90.0 >91.8

22 <90.5 ≥90.5 >92.2

30 <91.4 ≥91.4 >92.9

37 <92.0 ≥92.0 >93.3

45 <92.5 ≥92.5 >93.7

55 <93.0 ≥93.0 >94.0

75 <93.6 ≥93.6 >94.6

90 <93.9 ≥93.9 >95.0

Motors 2 poles

kWefficiency

eff3 eff2 eff1

1.1 <76.2 ≥76.2 >83.8

1.5 <78.5 ≥78.5 >85.0

2.2 <81.0 ≥81.0 >86.4

3 <82.6 ≥82.6 >87.4

4 <84.2 ≥84.2 >88.3

5.5 <85.7 ≥85.7 >89.2

7.5 <87.0 ≥87.0 >90.1

11 <88.4 ≥88.4 >91.0

15 <89.4 ≥89.4 >91.8

18.5 <90.0 ≥90.0 >92.2

22 <90.5 ≥90.5 >92.6

30 <91.4 ≥91.4 >93.2

37 <92.0 ≥92.0 >93.6

45 <92.5 ≥92.5 >93.9

55 <93.0 ≥93.0 >94.2

75 <93.6 ≥93.6 >94.7

90 <93.9 ≥93.9 >95.0

EURO W/ Kg W/ KgNORM a 1T a 1,5T

106- 84 1,70 4,00

data at 400V 50Hz

Instead, no standard prescribes amaximum loosing factor for Fe P01lamination sheets; although we cansay that generally this is at leastthe double of FeV laminationsheets,not even this data can beguaranteed. This is a source ofpotential performance diversitiesbetween motor and motor.

The reason of a longer life is basedon the lower heating that lengthensthe ageing cycle of the insulationmaterials.

Between all the raw materials thatcompose an asynchronous electricmotor, lamination sheets iron ist h e m a i n p e r f o r m a n c ediscriminating factor.

The main advantages given by theadoption of silicon magneticlaminations are:• higher efficiency• better guarantees on the quality

constancy, assured bytolerances reported ininternational norms

on the shaft. Basically, an highefficiency motor is the result ofprecise workings, lower frictions,a dynamically balanced rotor,smaller space between rotor andstator and of the use of bettermaterials. The main factors forthe design are based on the choiceof the type of lamination sheetsand windings with a greater coilnumber and a bigger diameterwire..Among all materials that composea motor, laminations have thehighest influence on performance

SILICON MAGNETIC LAMINATIONSMotive motors are made with FeVmagnetic lamination sheets, ratherthan the customary normal Fe P01iron lamination sheets.

Further than raw material, thesheets thickness is anotherperformance source.In fact, the thinner is the sheet,the higher are the performances.

The lamination sheets Fe P01can reach up to 1mm thickness.

FeV magnetic lamination sheetshave a 0,5mm max imumthickness.

Composition and thickness give tomagnetic lamination sheets a verylow W/Kg loosing factor:

Lower specific losses mean lessmagnetising current for the samePower and torque (thus lessheating).

Page 7: REV.0 GENERAL CATALOGUE - Emco Engineers

7

II 3 D

In order to meet the safety concerns in dust-filledatmospheres, the Delphi series motors are alsoavailable, upon request, in the version Delphi Ex.Conforming to the Essential safety requirement of theATEX 94/9/EC European Directive (ATEX 95), thesemotors have been designed to operate in the zone 22(Group II Category 3 D Tmax surf. 125°C).

Their “Ex” marking refers to the following norms:

Community Low Voltage Directive(LVD) 73/23 EEC, modified by theCommunity Directive regardingmarking 93/68 EEC

Community ElectromagneticCompatibility Directive (EMC) 89/336EEC and its modifications 91/263EEC, 92/31 EEC e 93/68 EEC

Community Machinery Directive (MD)89/392 EEC and its modifications91/368 EEC, 93/44 EEC e 93/68EEC

CE marking is put by Motive as avisible sign of the product compliancewith the requirements of abovementioned directives. In order to reachthis conformity, Motive productsrespect the following productstandards:

EN 60034-1 (last issue). Rotatingelectrical machines. Part 1: ratingand performance

EN 60034-5 (last issue). Rotatingelectrical machines. Part 5:classification of degrees of protection

EN 60034-6 (lasti issue). Rotatingelectrical machines. Part 6:methods of cooling (IC code)

EN 60034-9 (last issue). Rotatingelectrical machines. Part 9: noiselimits

EN 50081-1 (last issue).Electromagnetic compatibility- Generic emission standard- Part 1: residential and lightindustry environment

marking is referred to:

CE MARKING SERIE DELPHI EX

CEI EN 50281-1-1CEI EN 50281-1-1/A1

1999-112002-10

Electrical apparatus for use in thepresence of combustible dustPart 1-1: Electrical apparatusprotected by enclosures – Constructionand testing

CEI EN 50281-2-1 1999-11Electrical apparatus for use in thepresence of combustible dust.Part 2-1: Test methods – Methodsfor determining the minimum ignitiontemperatures of dust

CEI EN 50281-1-2 1999-09Electrical apparatus for use in thepresence of combustible dustPart 1-2: Electrical apparatusprotected by enclosuresSelection, installation and maintenance

CEI EN 50014CEI EN 50014/A1/A2

1998-061999-08

Electrical apparatus for potentiallyexplosive atmospheres.General requirements

EN 50082-1 ( last issue).Electromagnetic compatibility - Genericimmunity standard - Part 1: residentialand light industy environment

EN 50081-2 ( last issue).Electromagnetic compatibility - Genericemission standard - Part 2: Industrialenvironment

EN 50082-2 ( last issue).Electromagnetic compatibility - Genericimmunitystandard - Part 2: Industrialenvironment

Page 8: REV.0 GENERAL CATALOGUE - Emco Engineers

N

a

b

c

d

Tmax

8

* OPTIONAL

DUTY SERVICE

All Motive motors shown in this catalogueare made for S1 continuous duty service,as per IEC 34-1 norm. The duty serviceclass is shown on the rating plate.Below are described the various types ofservice:

S1 - Continuous service:operating at constant load of durationN in order to reach a thermal balance.

S2 Limited-duration service: operating atconstant load of duration N, less thanthe time necessary to reach a thermalbalance followed by a rest periodsufficient in order to restore the balancebetween the machine temperature andthat of the cooling fluid, with a toleranceof 2° C.

S3 Periodic intermittent service:sequence of identical operating cycles,each including a period of operation atconstant load N and a rest period R.In this type of service, the cycles issuch that start-up does not significantlyaffect the peak temperature.

S4 - Periodic intermittent service with start-up: sequence of identical operatingcycles, each including a substantial start-up stage D, a constant-load operatingperiod N and a rest period R.

S5 - Periodic intermittent service with electricbraking: sequence of operating cyclesas for S4, with the addition of a rapidelectric braking F.

S6 Uninterrupted periodic service withintermittent load: sequence of identicaloperating cycles, each including aconstant load operating period N anda no-load period V.No rest time is included

S7 Uninterrupted periodic service withelectric braking: sequence of operatingcycles as for S5, but without a restperiod

S8 Uninterrupted periodic service withcorrelated load and velocity variations:sequence of identical operating cycles,each of which includes a constant-loadoperating period N corresponding to apre-set rotation speed, followed by oneor more operating periods with otherconstant loads N2, N3, et.,corresponding to different rotationspeeds. There is no rest period.

S9 Service with non-periodic variations inload and speed: service in which theload and speed generally vary in a non-periodic fashion within the admissibleoperating field. This service includesfrequently applied overloads which maybe greatly superior to the full load.

0

1

2

3

4

5

6

no protection

protection againstsolid corps biggerthan 50mm

protection againstsolid corps biggerthan 12mm

protection againstsolid corps biggerthan a 2,5mm

protection againstsolid corps biggerthan 1 mm

protection againstharmful dustdeposits

complete protectionagainst the totalpenetration of dust*

no protection

protection againstvertical water drops

protection againstwater drops fall upto 15° of inclination

protection againstwater drops up to60° of inclination

protection againstwater sprayed byall directions

protection against waterlaunched by a nozzle of6,3mm D with a watercapacity 12,5lt/min at adistance of maximum 3mt for 3 min

protection against waterprojections similar to seawaves*

1° number 2° number

The protection against people accidentalcontacts and/or the entry of corps and/orthe entry of water is expressed at internationallevel (EN60529) by a symbolic acronymcomposed by a group of 2 letters and 2numbers.

IP index of protection reference letters

1° num. Protection of people against contactsand protection against the entry of solid corps

2° num. Protection against harmful entry ofwater

Motive motors are IP55 protected

PROTECTION TYPE

*

a = loadb = electric lossesc = temperatured = timeN = steady load operating timeTmax= max temperature achieved

RAIN SHIELDFor outdoor applications with V5 - V18 - V1 - V15installation, we recommend to mount a rain shield.This configuration may also be used in textilesprocessing industry.

TYPE63718090S90L100112132S132M160M160L180M180L200L225S225M250M280S280M315S315M315L355M355L

L215323369403428469453573613770825915955

10251155116012201265131515401570168018401870

3

Page 9: REV.0 GENERAL CATALOGUE - Emco Engineers

9

WORKING CONDITIONS

HUMIDITY:The electrical equipment must be able towork with a relative humidity between 30and 95% (without condensation).Damaging effects of occasional condensationmust be avoided by adequate equipmentdesign or, if necessary, by additional measures(for example, built-in heating or air-conditioningequipment, drainage holes).

ALTITUDE AND TEMPERATURE:the powers indicated are intended for regularuse at altitudes below 1000 mt above sealevel and a room temperature between +5°Cand +40°C for motors having a rated powerbelow 0.6 kW, or between -15°C and 40°Cfor motors having a rated power equal toor greater than 0.6 kW (IEC 34-1): Forworking conditionsrather than those specified (higher altitudeand/or temperature) the power decreasesof 10% each 10°C of higher temperature,and of 8% for each 1000 mt of higheraltitude.It is not necessary to reduce the rated powerif at an altitude higher than 1000mt andlower than 2000mt there is a max ambienttemperature of 30°C or, in altitudes from2000 mt to 3000mt there is a max ambienttemperature of 19°C.

VOLTAGE - FREQUENCY:The maximum variation of the supply voltageis +-10%.Within this tolerance Motive motors supplythe rated power.

Classe ∆T (°C) Tmax (°C)

A 60+5° 105

E 75+5° 120

B 80+5 130

F 105+5° 155

H 125 180

INSULATION:The copper is impregnated with a doublelayer of H class insulating enamel to ensurehigh resistance to electrical, thermal andmechanical stress.A NOMEX*/D.M./D.M.D./N.M./N.M.N./M. film that wraps entirely around the coilside insulates the copper and iron from oneanother.The phases are further isolated by anotherlayer of NOMEX*/D.M./D.M.D./N.M./N.M.N./M. to protect the motors fromvoltage peaks that usually occur when themotor is controlled by inverter.Below is a graph showing the operatingtemperatures possible for stator windingsbased on the insulation rating shown onthe machine plate

Motive motors are designed to not to passthe max temperatures of their class evenunder S1 continuous duty service.

ASSISTED POWER COOLING

For applications with a power supply below a frequency of50Hz, the appropriate assisted power cooling must bemounted as there are too many variables involved to determinethe various possible thermal duties, and thus the temperaturesreached by the motors

three-phase 400/50 400/60, IP 55, with separate terminal box

ENCODER

motors with encoder or special shaft configurations for encoder mounting are available uponrequest. In this case, assisted power cooling is also available, supported by brackets on thefan cover

TYPE

718090S90L100112132S132M160M160L180M180L200L225S225M250M280S280M315S315M315L355M355L

POWERW30355050656590909090

100100180200200320370370500500500600600

CAPACITYm3/h300350500500650

1000880880

110011001200120025003800380042005000500060006000600065006500

LSIZE320366400425466450570610710765805845910

1035104011101160121014101440155017151745

Page 10: REV.0 GENERAL CATALOGUE - Emco Engineers

10

MOTIVE MOTORS PROTECTION

protections must be chosen based on thespecific running conditions, according tostandards EN 60204-1.

Protection for motors with a shaft powergreater than or equal to 0.5 kW withcontinuous S1 service. This protectionmay be achieved by means of a thermalcut-out relay, which automatically controla knife switch.

Protection against peak currents bymagnetic relay that controls an automaticknife switch, or by fuses; these must beset to the locked rotor current.

If the application requires, protectionagainst excessive speed of the electricmotor, for example if the mechanicalload may drive the electric motor itselfand thereby create a hazardous situation.

If special conditions or synchronisedoperation with other machines or partsof machines require it, protection againstpower failures or dips by means of aminimum voltage relay that controls anautomat ic power kni fe switch.

The electrical protections on the motorpower line may not be sufficient to protectagainst overloads. If the cooling conditionsworsen, the motor overheats but theelectrical conditions do not change, whichinhibits line protections. Installing built-inprotections on the windings solvesthis problem:

PTO bimetallic devicethis is a normally-closed electromechanicaldevice that opens electrically when thethreshold temperature is reached; itautomatically resets when the temperaturefalls below the threshold level. Bimetallicdevices are available with variousintervention temperatures and withoutautomatic reset, per EN 60204-1.

PTC thermistor devicethis device promptly, positively adjustsits resistance once the thresholdtemperature is reached. Motivemotors from type 160 to type 355Lare equipped with 3 PTC thermistorsin the winding, with temperatureintervention of 150°C in Class Fmotors (standard), or 180°C in HClass motors.

PT100 devicethis is a device that continuously,increasingly adjusts its resistanceaccording to the temperature. It is usefulfor constant measuring of thewinding temperatures using electronicequipment.

Page 11: REV.0 GENERAL CATALOGUE - Emco Engineers

THREE-PHASE SELF-BRAKING MOTORS SERIES DELPHI ATDC

Page 12: REV.0 GENERAL CATALOGUE - Emco Engineers

12

DELPHI ATDCKW HP

Brakingtorquefull-load

Nm

Brakingtorqueno-load

sec

0,18

0,25

0,37

0,55

0,75

1,1

1,5

2,2

3

4

5,5

7,5

11

15

18,5

0,12

0,18

0,25

0,37

0,55

0,75

1,1

1,5

2,2

3

4

5,5

7,5

11

15

0,37

0,55

0,75

1,1

1,5

2,2

3

4

5,5

7,5

11

ATDC 63A-2

ATDC 63B-2

ATDC 71A-2

ATDC 71B-2

ATDC 80A-2

ATDC 80B-2

ATDC 90S-2

ATDC 90L-2

ATDC 100L-2

ATDC 112M-2

ATDC 132SA-2

ATDC 132SB-2

ATDC 160MA-2

ATDC 160MB-2

ATDC 160L-2

ATDC 63A-4

ATDC 63B-4

ATDC 71A-4

ATDC 71B-4

ATDC 80A-4

ATDC 80B-4

ATDC 90S-4

ATDC 90L-4

ATDC 100LA-4

ATDC 100LB-4

ATDC 112M-4

ATDC 132S-4

ATDC 132M-4

ATDC 160M-4

ATDC 160L-4

ATDC 80A-6

ATDC 80B-6

ATDC 90S-6

ATDC 90L-6

ATDC 100L-6

ATDC 112M-6

ATDC 132S-6

ATDC 132MA-6

ATDC 132MB-6

ATDC 160M-6

ATDC 160L-6

4,0

4,0

4,0

4,0

7,5

7,5

15,0

15,0

30,0

40,0

75,0

75,0

150,0

150,0

150,0

4,0

4,0

4,0

4,0

7,5

7,5

15,0

15,0

30,0

30,0

40,0

75,0

75,0

150,0

150,0

7,5

7,5

15,0

15,0

30,0

40,0

75,0

75,0

75,0

150,0

150,0

0,15

0,15

0,15

0,15

0,20

0,20

0,25

0,25

0,30

0,35

0,40

0,40

0,50

0,50

0,50

0,15

0,15

0,15

0,15

0,20

0,20

0,25

0,25

0,30

0,30

0,35

0,40

0,40

0,50

0,50

0,20

0,20

0,25

0,25

0,30

0,35

0,40

0,40

0,40

0,50

0,50

25

25

25

25

50

50

60

60

80

110

130

130

150

150

150

25

25

25

25

50

50

60

60

80

80

110

130

130

150

150

50

50

60

60

80

110

130

130

150

150

150

7,8

8,1

9,0

9,5

12,7

13,5

16,3

18,0

27,0

37,0

49,1

54,5

84,2

93,0

103,5

7,8

8,1

9,0

9,5

13,4

14,8

16,5

18,3

26,8

29,5

37,5

51,5

57,5

87,5

100,6

12,9

14,4

16,6

18,2

29,0

36,2

50,2

53,0

57,2

85,6

90,0

0,25

0,35

0,5

0,75

1

1,5

2

3

4

5,5

7,5

10

15

20

25

0,18

0,25

0,35

0,5

0,75

1

1,5

2

3

4

5,5

7,5

10

15

20

0,5

0,75

1

1,5

2

3

4

5,5

7,5

10

15

TypeBrake input

powerW

Kg

TYPE L

ATDC 63ATDC 71ATDC 80ATDC 90SATDC 90LATDC 100LATDC 112MATDC 132SATDC 132MATDC 160MATDC 160L

240270375400426465495570610715760

Delphi ATDC series self-braking motors use spring-pressure brakes, firmly spliced ontoa cast iron shield at the back of the motor.These motors include a series of characteristics normally considered options by otherbrands, like:The hand release lever permits to release the brake, making it possible to move theshaft.The separate brake power supply is achieved, whenever needed, by connecting directlyto the brake terminal board located inside the motor terminal box.The PTO thermal protectors in the winding

Page 13: REV.0 GENERAL CATALOGUE - Emco Engineers

� �

� �

S �

�� �

13

BRAKE DESCRIPTION BRAKE OPERATION ADJUSTMENT

Mobile armature

springs

Brake disc

Driver

Motor shaft

Motor flange

Electromagnet

Release lever

Adjuster screws

Threaded bush

Air gap

S

S

The adjustment is made by using thethreaded bushes �, using a thicknessgauge to make sure that the wished airgap is reached.

Braking torque adjustmentThe braking torque can be increased by tightening the adjuster screws �. The settinghas already been made by motive at the max value, and therefore we suggest to notto intervene on it.

Two different types of adjustment are possible

S air gap adjustmentFor proper operation, the air gap S between electromagnet and the mobile armature� must be between the following indicated limits:

When the power supply is interrupted, theexcitation coil is no longer powered andtherefore doesn’t exert the magnetic forcenecessary to restrain the mobile armature�, hwich, pushed by the pressure springs�, compresses the brake disk � againstthe motor flange � on one side and thearmature itself on the other, thereby creatinga braking action.

The Delphi ATDC series brake is anelectromagnetic brake with negativeoperation, whose braking action is exercisedin the absence of power supply.The brake insulation class is F.The brake lining is asbestos-free, as permost recent EEC Directives in terms ofWorkplace Hygiene and Safety.All brake assemblies are protected againstcorrosion by painting and/or heatgalvanizing. The parts most subject to wearare treated in special atmospheres thatprovide considerable wear resistance tothe parts.The standard supply voltage of the brakeis 230V±10% 50/60Hz on the AC of the brakepower pack

Mobile armature

springs

Brake disc

Driver

Motor shaft

Motor flange

Electromagnet

Release lever

Adjuster screws

Threaded bush

Air gap

MOTOR TYPE S AIR GAP (mm)

63˜71 0.40˜0.50

80˜160 0.50˜0.60

Page 14: REV.0 GENERAL CATALOGUE - Emco Engineers

14

DELTA CONNECTIONDelta connection is obtained by connecting the end of aphase with the beginning of the following one.The phase current Iph and the phase voltage Uph arerepectively:Iph = In / 3 -2Uph = Unwhere In and Un are referred to Delta connection.

WIRING DIAGRAMS

Motive three phase motors can be connected “Star” or “Delta”.

STAR CONNECTIONStar connection is obtained by connecting together theterminals W2, U2, V2 and supplying the terminalsU1, V1, W1.The phase current and voltage are respectively:Iph = InUph = Un / 3 -2where In is the supply line current and Un is the supplyline voltage of Star connection

the fo l lowing vo l tages andfrequencies are inside the standardpower supply of all three-phasemotive motors, under S1 dutyservice:

Size

Volts

50

60

56-132

400

380

415

440

460

480

Hz

690

660

720

760

795

830

50

60

132-355

230

220

240

260

265

280

400

380

415

440

460

480

Page 15: REV.0 GENERAL CATALOGUE - Emco Engineers

IM1051 (IM B6) IM1001 (IM B3)

IM1071 (IM B8) IM1031 (IM V6)

IM1061 (IM B7) IM1011 (IM V5)

IM2001 (IM B35) IM2101 (IM B34)

B3/B5 B3/B14

IM3001 (IM B5)

IM3011 (IM V1)

IM3031 (IM V3)

IM2011 (IM V15)

V1/V5

IM3601 (IM B14)

IM3611 (IM V18)

IM3631 (IM V19)

IM2031 (IM V36)

V3/V6

15

FLANGE-MOUNTEDMOTORS B14

FLANGE-MOUNTEDMOTORS B5

MOTORS WITHFEET B3

CONSTRUCTION FORMS AND SIZE TABLES

MOTOR CONFIGURATIONS AND INSTALLATION POSITIONS (IEC 34-7)

Page 16: REV.0 GENERAL CATALOGUE - Emco Engineers

16

B3

56

63

71

80

90S

90L

100

112M

132S

132M

160M

160L

180M

180L

200L

225S

225M

225M

250M

250M

280S

280S

280M

280M

315S

315S

315M

315M

315L

315L

355M

355M

355L

355L

2-8

2-8

2-8

2-8

2-8

2-8

2-8

2-8

2-8

2-8

2-8

2-8

2-8

2-8

2-8

4-8

2

4-8

2

4-8

2

4-8

2

4-8

2

4-8

2

4-8

2

4-8

2

4-8

2

4-8

120

130

145

175

195

195

215

240

275

275

330

330

380

380

420

470

470

470

510

510

580

580

580

580

645

645

645

645

645

645

710

710

710

710

102

114

119

130

145

145

170

177

197

197

255

255

280

280

305

335

335

335

370

370

410

410

410

410

530

530

530

530

530

530

655

655

655

655

56

63

71

80

90

90

100

112

132

132

160

160

180

180

200

225

225

225

250

250

280

280

280

280

315

315

315

315

315

315

355

355

355

355

M16

M20

M20

M20

M20

M20

M20

M25

2xM32

2xM32

2xM40

2xM40

2xM40

2xM40

2xM50

2xM50

2xM50

2xM50

2xM63

2xM63

2xM63

2xM63

2xM63

2xM63

2xM63

2xM63

2xM63

2xM63

2xM63

2xM63

2xM63

2xM63

2xM63

2xM63

164

212

240

276

305

330

371

380

455

495

615

670

700

740

770

815

820

845

910

910

985

985

1035

1035

1160

1270

1190

1300

1190

1300

1500

1530

1500

1530

9

11

14

19

24

24

28

28

38

38

42

42

48

48

55

60

55

60

60

65

65

75

65

75

65

80

65

80

65

80

75

95

75

95

M4x12

M4x12

M5X12

M6X16

M8X19

M8X19

M10X22

M10X22

M12X28

M12X28

M16X36

M16X36

M16X36

M16X36

M20X42

M20X42

M20X42

M20X42

M20X42

M20X42

M20X42

M20X42

M20X42

M20X42

M20X42

M20X42

M20X42

M20X42

M20X42

M20X42

M20X42

M20X42

M20X42

M20X42

20

23

30

40

50

50

60

60

80

80

110

110

110

110

110

140

110

140

140

140

140

140

140

140

140

170

140

170

140

170

140

170

140

170

3

4

5

6

8

8

8

8

10

10

12

12

14

14

16

18

16

18

18

18

18

20

18

20

18

22

18

22

18

22

20

25

20

25

7,2

8,5

11,0

15,5

20,0

20,0

24,0

24,0

33,0

33,0

37,0

37,0

42,5

42,5

49,0

53,0

53,0

56,0

56,0

67,5

58,0

67,5

58,0

71,0

58,0

71,0

58,0

71,0

58,0

71,0

67,5

86,0

67,5

86,0

111

123

138

157

173

173

196

227

262

262

320

320

355

355

395

435

435

435

490

490

550

550

550

550

635

635

635

635

635

635

730

730

730

730

71

80

90

100

100

125

140

140

140

178

210

254

241

279

305

286

311

311

349

349

368

368

419

419

406

406

457

457

508

508

500

500

630

630

36

40

45

50

56

56

63

70

89

89

108

108

121

121

133

149

149

149

168

168

190

190

190

190

216

216

216

216

216

216

254

254

254

254

5,8

7

7

10

10

10

12

12

12

12

15

15

15

15

19

19

19

19

24

24

24

24

24

24

28

28

28

28

28

28

28

28

28

28

90

100

112

125

140

140

160

190

216

216

254

254

279

279

318

356

356

356

406

406

457

457

457

457

508

508

508

508

508

508

610

610

610

610

80

95

110

130

130

130

180

180

230

230

250

250

250

250

300

350

350

350

450

450

450

450

450

450

550

550

550

550

550

550

680

680

680

680

120

140

160

200

200

200

250

250

300

300

350

350

350

350

400

450

450

450

550

550

550

550

550

550

660

660

660

660

660

660

800

800

800

800

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

7

10

10

12

12

12

15

15

15

15

19

19

19

19

19

19

19

19

19

19

19

19

19

19

24

24

24

24

24

24

24

24

24

24

3

3

3,5

3,5

3,5

3,5

4

4

4

4

5

5

5

5

5

5

5

5

5

5

5

5

5

5

6

6

6

6

6

6

6

6

6

6

65

75

85

100

115

115

130

130

165

165

215

215

50

60

70

80

95

95

110

110

130

130

180

180

80

90

105

120

140

140

160

160

200

200

250

250

0

0

0

0

0

0

0

0

0

0

0

0

M5

M5

M6

M6

M8

M8

M8

M8

M10

M10

M12

M12

2,5

2,5

2,5

3,0

3,0

3,0

3,5

3,5

3,5

3,5

4,0

4,0

100

115

130

165

165

165

215

215

265

265

300

300

300

300

350

400

400

400

500

500

500

500

500

500

600

600

600

600

600

600

740

740

740

740

TYPE POLES AC AD H KK L D DH E F G A AB B C K M N P R S T M N P R S T

B5, B3/B5 B14

Page 17: REV.0 GENERAL CATALOGUE - Emco Engineers

17

B3

B5, B3/B5

B14

Page 18: REV.0 GENERAL CATALOGUE - Emco Engineers

Nm

Cs

0

C max

Cn

rpm

230 230 1 1,2 1,2 0,8 0,8 0,8

230 240 1,1 1,2 1,15 0,9 0,9 0,9

230 260 1,2 1,2 1 1 1 1

400 400 1 1,2 1,2 0,8 0,8 0,8

400 440 1,06 1,2 1,1 0,87 0,87 0,87

400 460 1,2 1,2 1 1 1 1

400 480 1,25 1,2 1 1,1 1,1 1,1

Volt 230 380 400 440 690

In 1,74 1,05 1,0 0,91 0,5818

The general electrical specifications are listed in the performance charts that follow. To understand their contents, the following general definitions are provided.

TECHNICAL DATA

Motive motors can face also temporaryoverloads, with Current increases of1.5 times the rated current for at least2 minutes.

Starting current (or locked rotor current):In the performance charts the startingcurrent “Is” is indicated as a multiplevalue of the rated current (Is/In).

Synchronous speed:is expressed in rpm and it is obtainedby the formula

f 120/pf= supply frequency Hzp= number of poles pairs

Rated Power:it is the mechanical power measured atthe shaft expressed, according to thelatest indications of internationalStandards Committees, in Watts orKwatts. However, in the engineeringsector it is still common to refer topower in terms of HP

Rated Voltage:the voltage to be applied to the motorterminals in accordance with thespecifications in the following tables

Frequency:All electrical data in this catalogue referto three-phase wound motors at 50 Hz.These may be connected to 60 Hz,taking into account the multipliercoeff icients in the table below

Rated Current:“In” is the Rated Current, expressed inAmpere, absorbed by the motor whensupplied at rated voltage and giving theRated Power. In the following tables, therated currents are referred to a Voltagesupply of 400V. For other voltage suppliesthe absorbed rated current can beconsidered inversely proportional to thevoltage supply. EX:

Rated torque:Cn is expressed in Nm, and itcorresponds to the rated power andrated rpm. It is given by the It is givenby the multiplication of the force for thearm (distance) and it is measured inNm because the force is expressed inin Newton and the distance in metres.The rated torque value is obtained bythe formula

Cn (Nm) = 9,55 x (Pn/n)Pn= Rated power in KWn= rated rotation speed in rpm

Starting torque (or locked rotor torque):Cs is the torque that the motor canprovide with the rotor at a standstill andthe rated power supply.

Maximum torque:Cmax is the maximum torque developedby the motor at the rated power supply,at a certain speed.It represents also the value of theresistant torque after which the motorstops.In the following performance charts, itis indicated the relation betweenmaximum torque and rated torque andmaximum torque (Cmax/Cn)

Efficiency:η is expressed in % and it is given bythe relation between the output Powerand the addition of output Power andthe electric losses of the motor, that isthe input power absorbed by the motor.The electric motors losses are mainlyof two kinds: for joule effect (rotor andstator) and iron losses.The latest cause essentially heat.An higher efficiency means energysavings, lower heating, longer life ofinsulating materials.

Power factor or cosϕ:it represents the coseno of the voltageand current gap angle.

rated voltageat 50Hz

Volt at60Hz

ratedpower

Wrpm In

IaIn

CaCn

CmaxCn

for further information, see chapter "wiring diagrams" at page 14

Page 19: REV.0 GENERAL CATALOGUE - Emco Engineers

19

Noise:The noise is expressed in dB(A). Themeasures must be taken in accordancewith the standard ISO 1680-2, in orderto find the Sound Power level LwAmeasured at 1m of distance from theperimeter of the machine.EN 60034-9 standard describes theacoustic Power limits to be respected,indicating the maximum sound powerlevel LwA. The noise values indicatedin the performance charts that followare referred to a no-load motor working,supplied at 50Hz and with a toleranceof +3 dB(A).

The moment of inertia can be calculatedin this way:J = (1/2) x M x (R2)Where M [Kg] is the rotation mass,while R [m] is the ray of the volume atcylindrical symmetry.

TOLERANCES

Efficiency -15% di (1- n)(Output Power

input Power)

Power factor 1/ 6 of (1- cosϕ) min. 0.02max 0.07

Locked rotor torque -15% of the guaranteed torque+25% of the guaranteed torque

Maximum torque -10% -of the guaranteed torque, if torque is not lessthan 1,5- 1,6 the rated torque

Noise +3dB

Characteristic Tolerance

The data of each motor are specified inthis catalogue like requested by the normIEC 34-1. This describes, in particular, thefollowing tolerances:

Page 20: REV.0 GENERAL CATALOGUE - Emco Engineers

20

0,09

0,13

0,18

0,25

0,37

0,55

0,75

1,1

1,5

2,2

3

4

5,5

7,5

9,2

11

15

18,5

22

30

37

45

55

75

90

110

132

160

200

250

315

56A-2

56B-2

63A-2

63B-2

71A-2

71B-2

80A-2

80B-2

90S-2

90L-2

100L-2

112M-2

132SA-2

132SB-2

132MA-2

160MA-2

160MB-2

160L-2

180M-2

200LA-2

200LB-2

225M-2

250M-2

280S-2

280M-2

315S-2

315MA-2

315LA-2

315LB-2

355M-2

355L-2

2800

2800

2800

2800

2800

2800

2825

2825

2840

2840

2880

2890

2900

2900

2930

2930

2930

2930

2940

2950

2950

2970

2970

2970

2970

2980

2980

2980

2980

2985

2985

0,3

0,3

0,5

0,6

0,9

1,3

1,7

2,4

3,2

4,6

5,9

7,7

10,3

14,0

16,9

19,9

26,9

32,4

41,0

55,5

67,9

82,3

100,4

134,4

160,2

195,4

233,2

265,0

330,0

411,0

517,0

5,2

5,2

5,5

5,5

6,1

6,1

6,1

7,0

7,0

7,0

7,5

7,5

7,5

7,5

7,5

7,5

7,5

7,5

7,5

7,5

7,5

7,5

7,5

7,5

7,5

7,1

7,1

7,1

7,1

7,1

7,1

0,31

0,41

0,61

0,96

1,26

1,88

2,54

3,72

0,21

7,40

9,95

13,22

18,11

24,70

25,60

35,85

48,89

60,30

71,46

97,12

119,78

144,70

176,85

241,16

289,39

352,51

423,02

512,75

640,94

799,83

100,79

2,1

2,1

2,2

2,2

2,2

2,2

2,2

2,2

2,2

2,2

2,2

2,2

2,2

2,2

2,2

2,2

2,2

2,2

2,0

2,0

2,0

2,0

2,0

2,0

2,0

1,8

1,8

1,8

1,8

1,8

1,8

0,12

0,18

0,25

0,35

0,5

0,75

1

1,5

2

3

4

5,5

7,5

10

12,5

15

20

25

30

40

50

60

75

100

125

150

180

215

270

340

430

2,2

2,2

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,2

2,2

2,2

2,2

2,2

2,2

62,0

64,0

66,0

69,0

71,0

74,0

76,2

79,3

80,4

81,6

83,5

85,5

86,5

87,1

87,1

88,4

89,4

90,5

90,5

91,4

92,0

92,5

93,0

93,6

94,1

94,4

94,8

95,0

95,0

95,0

95,2

61,0

63,5

64,0

68,5

71,0

73,0

75,7

80,0

80,2

82,7

83,4

85,5

84,5

86,9

86,9

87,4

88,5

90,2

89,9

90,3

91,2

90,9

91,9

93,1

93,1

93,9

94,3

94,5

94,5

94,0

95,2

0,77

0,78

0,80

0,81

0,81

0,82

0,83

0,84

0,84

0,85

0,88

0,88

0,89

0,89

0,89

0,89

0,89

0,91

0,89

0,85

0,89

0,89

0,86

0,90

0,90

0,90

0,88

0,91

0,90

0,90

0,91

0,71

0,73

0,73

0,74

0,75

0,76

0,78

0,82

0,80

0,84

0,85

0,85

0,88

0,89

0,88

0,87

0,88

0,90

0,89

0,83

0,87

0,88

0,84

0,88

0,87

0,87

0,85

0,88

0,88

0,88

0,89

60

60

61

61

64

64

67

67

72

72

76

77

80

80

81

86

86

86

89

92

92

92

93

94

94

96

96

99

99

103

103

3,5

3,6

4,5

4,7

6

6,3

10

11

13

14

25

28

40

45

49

110

120

135

165

217

243

320

390

540

590

880

1000

1055

1110

1900

2300

0,00010

0,00020

0,00031

0,00040

0,00055

0,00060

0,00075

0,00090

0,00120

0,00140

0,00290

0,00550

0,01090

0,01260

0,02000

0,03770

0,04990

0,05500

0,07500

0,12400

0,13900

0,23300

0,31200

0,57900

0,67500

1,18000

1,82000

2,08000

2,38000

3,00000

3,50000

PowerKW

PowerHP Type rpm

CurrentIs/In

TorqueCn (Nm)

TorqueCs/Cn

TorqueCmax/Cn

Efficiency η100% 75%

CurrentIn (A)

Pwr. Fact. cosϕ100% 75%

LwA

(dB)

J

Kgm2Kg

2 Poles asynchronous speed 3000 rpm

Page 21: REV.0 GENERAL CATALOGUE - Emco Engineers

21

0,06

0,09

0,13

0,18

0,25

0,25

0,37

0,55

0,55

0,75

1,1

1,1

1,5

2,2

2,2

3

4

5,5

5,5

7,5

9,2

11

15

18,5

22

30

37

45

55

75

90

110

132

160

200

250

315

56A-4

56B-4

63A-4

63B-4

63C-4

71A-4

71B-4

71C-4

80A-4

80B-4

80C-4

90S-4

90L-4

90LB-4

100LA-4

100LB-4

112M-4

112MB-4

132S-4

132MA-4

132MB-4

160M-4

160L-4

180M-4

180L-4

200L-4

225S-4

225M-4

250M-4

280S-4

280M-4

315S-4

315M-4

315LA-4

315LB-4

355M-4

355L-4

1340

1340

1360

1360

1330

1380

1380

1340

1400

1400

1390

1400

1400

1390

1420

1420

1440

1440

1440

1460

1460

1460

1460

1470

1470

1480

1480

1480

1480

1480

1485

1485

1485

1485

1485

1485

1485

0,20

0,30

0,40

0,60

0,73

0,80

1,06

1,44

1,49

1,93

2,67

2,75

3,52

4,86

4,90

6,44

8,36

11,20

11,20

14,80

17,90

21,10

28,60

34,60

41,00

54,70

66,40

80,40

97,80

133,00

158,70

191,00

228,00

273,00

341,00

421,00

528,00

4,0

4,0

4,4

4,4

4,9

5,2

5,2

5,2

5,2

6,0

6,0

6,0

6,0

7,0

7,0

7,0

7,0

7,0

7,0

7,0

7,0

7,0

7,5

7,5

7,5

7,2

7,2

7,2

7,2

7,2

7,2

6,9

6,9

6,9

6,9

6,9

6,9

0,43

0,64

0,84

1,26

1,51

1,73

2,54

3,12

3,78

5,15

7,10

7,50

10,23

13,20

14,80

20,18

26,53

32,30

36,48

49,74

60,05

71,59

98,12

120,19

142,93

160,96

198,51

290,37

354,90

483,95

578,79

707,41

848,89

1028,96

1286,20

1602,35

2018,96

2,0

2,0

2,1

2,1

2,1

2,1

2,1

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,2

2,2

2,2

2,2

2,2

2,2

2,2

2,2

2,1

2,1

2,1

2,1

2,1

2,1

0,09

0,12

0,18

0,25

0,35

0,35

0,5

0,75

0,75

1

1,5

1,5

2

3

3

4

5,5

7,5

7,5

10

12,5

15

20

25

30

40

50

60

75

100

120

150

180

220

270

340

430

2,1

2,1

2,2

2,2

2,2

2,2

2,2

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,3

2,2

2,2

2,2

2,2

2,2

2,2

56,0

58,0

59,0

62,0

64,3

68,0

69,3

72,0

72,8

74,4

76,2

76,4

78,5

81,5

82,5

82,6

85,0

85,9

86,7

87,9

87,9

89,2

89,7

90,7

91,6

92,6

92,8

93,4

94,0

94,0

94,0

94,0

94,8

95,0

95,0

95,0

95,0

55,6

58,2

59,0

61,5

64,0

66,5

71,0

71,5

72,6

74,2

76,0

77,8

78,1

81,0

83,0

83,2

84,8

85,1

86,8

88,2

88,2

89,2

89,7

90,6

91,7

92,4

92,7

93,3

94,2

93,5

93,5

93,5

94,8

94,5

94,1

94,4

95,0

0,69

0,7

0,72

0,73

0,74

0,74

0,76

0,75

0,75

0,74

0,77

0,79

0,81

0,79

0,82

0,86

0,83

0,83

0,87

0,87

0,85

0,85

0,85

0,89

0,88

0,87

0,87

0,89

0,89

0,91

0,88

0,88

0,91

0,88

0,89

0,89

0,89

0,61

0,61

0,63

0,65

0,66

0,65

0,65

0,66

0,66

0,65

0,7

0,7

0,75

0,71

0,76

0,78

0,76

0,79

0,81

0,83

0,83

0,83

0,82

0,86

0,85

0,84

0,84

0,87

0,88

0,89

0,86

0,87

0,88

0,85

0,87

0,87

0,86

52

52

52

52

55

55

55

58

58

58

61

61

61

64

64

64

65

71

71

71

72

75

75

76

76

79

81

81

83

86

86

93

93

97

97

101

101

3,5

3,6

4,5

4,7

5,7

6

6,3

7,3

10

11

12,5

13

14

16

23

25

28

35

45

55

59

118

132

164

182

245

258

290

388

510

606

910

1000

1055

1128

1700

1900

0,00015

0,00015

0,00030

0,00040

0,00045

0,00050

0,00080

0,00150

0,00180

0,00210

0,00220

0,00230

0,00270

0,00410

0,00540

0,00670

0,00950

0,01500

0,02140

0,02960

0,03100

0,07470

0,09180

0,13900

0,15800

0,26200

0,40600

0,46900

0,66000

1,12000

1,46000

3,11000

3,62000

4,13000

4,73000

6,50000

8,20000

4 Poles asynchronous speed 1500 rpm

PowerKW

PowerHP Type rpm

CurrentIs/In

TorqueCn (Nm)

TorqueCs/Cn

TorqueCmax/Cn

Efficiency η100% 75%

CurrentIn (A)

Pwr. Fact. cosϕ100% 75%

LwA

(dB)

J

Kgm2Kg

Page 22: REV.0 GENERAL CATALOGUE - Emco Engineers

22

0,18

0,25

0,37

0,55

0,75

1,1

1,5

2,2

3

4

5,5

7,5

11

15

18,5

22

30

37

45

55

75

90

110

132

160

200

250

71A-6

71B-6

80A-6

80B-6

90S-6

90L-6

100L-6

112M-6

132S-6

132MA-6

132MB-6

160M-6

160L-6

180L-6

200LA-6

200LB-6

225M-6

250M-6

280S-6

280M-6

315S-6

315MA-6

315LA-6

315LB-6

355MA-6

355MB-6

355L-6

900

900

900

900

910

910

940

940

960

960

960

970

970

970

970

970

980

980

980

980

980

985

985

985

990

990

990

0,70

0,90

1,20

1,70

2,10

3,0

3,70

5,20

6,80

9,0

11,90

16,0

22,50

31,60

38,60

44,70

59,30

71,10

85,90

104,70

141,70

169,50

206,70

244,70

277,00

347,00

432,00

4,0

4,0

4,7

4,7

5,5

5,5

5,5

6,5

6,5

6,5

6,5

6,5

6,5

7,0

7,0

7,0

7,0

7,0

7,0

7,0

7,0

6,7

6,7

6,7

6,7

6,7

6,7

1,91

2,65

3,93

5,84

7,87

11,54

15,24

22,35

29,84

39,79

54,71

73,84

108,30

147,68

182,14

216,60

292,35

360,56

438,52

535,97

730,87

872,59

1066,50

1279,80

1543,43

1292,29

2411,62

1,9

1,9

1,9

1,9

2,0

2,0

2,0

2,1

2,1

2,1

2,1

2,1

2,1

2,1

2,1

2,1

2,0

2,1

2,1

2,1

2,0

2,0

2,0

2,0

1,9

1,9

1,9

0,25

0,35

0,5

0,75

1

1,5

2

3

4

5,5

7,5

10

15

20

25

30

40

50

60

75

100

125

150

180

220

270

340

2,0

2,0

2,0

2,1

2,1

2,1

2,1

2,1

2,1

2,1

2,1

2,1

2,1

2,1

2,1

2,1

2,1

2,1

2,1

2,1

2,0

2,0

2,0

2,0

2,0

2,0

2,0

57,0

60,0

66,5

68,2

74,4

75,2

77,6

79,9

84,5

84,6

85,7

87,0

89,0

89,1

90,0

90,1

91,8

92,8

93,0

93,0

94,0

94,0

94,3

94,7

94,9

94,9

95,0

57,0

59,9

67,7

68,4

73,9

74,7

77,6

79,9

84,6

84,7

86,0

87,0

89,5

89,1

90,2

90,1

91,5

92,8

92,5

92,5

93,5

93,5

93,9

94,2

94,2

94,5

95,0

0,66

0,68

0,70

0,66

0,74

0,75

0,73

0,75

0,77

0,77

0,81

0,76

0,78

0,84

0,82

0,83

0,88

0,86

0,87

0,88

0,88

0,86

0,86

0,87

0,87

0,89

0,88

0,60

0,60

0,62

0,59

0,64

0,66

0,66

0,66

0,71

0,70

0,76

0,71

0,73

0,79

0,78

0,78

0,79

0,86

0,83

0,85

0,85

0,85

0,84

0,84

0,87

0,87

0,86

52

52

54

54

57

57

61

65

69

69

69

73

73

73

76

76

76

78

80

80

85

85

85

85

92

92

92

6

6,3

10

11

13

14

23

25

28

45

55

78

90

160

217

244

295

365

500

545

810

900

1010

1140

1550

1600

1700

0,00110

0,00140

0,00160

0,00190

0,00290

0,00350

0,00690

0,01400

0,02860

0,03570

0,04490

0,00810

0,11600

0,20700

0,31500

0,36000

0,54700

0,84300

1,39000

1,65000

4,11000

4,78000

5,45000

6,12000

9,50000

10,40000

12,40000

6 Poles asynchronous speed 1000 rpm

PowerKW

PowerHP Type rpm

CurrentIs/In

TorqueCn (Nm)

TorqueCs/Cn

TorqueCmax/Cn

Efficiency η100% 75%

CurrentIn (A)

Pwr. Fact. cosϕ100% 75%

LwA

(dB)

J

Kgm2Kg

Page 23: REV.0 GENERAL CATALOGUE - Emco Engineers

23

1,5

2,2

3

4

5,5

7,5

11

15

18,5

22

30

37

45

55

75

90

110

112M-8

132S-8

132M-8

160MA-8

160MB-8

160L-8

180L-8

200L-8

225S

225M-8

250M-8

280S-8

280M-8

315S-8

315MA-8

315MB-8

315MC-8

700

710

710

720

720

720

730

730

730

730

730

730

740

740

740

740

740

4,28

5,70

7,53

9,80

12,60

16,90

23,80

32,40

39,00

45,00

60,80

74,00

89,30

105,00

143,00

169,00

206,00

5,0

6,0

6,0

6,0

6,0

6,0

5,5

6,6

6,6

6,6

6,6

6,6

6,6

6,6

6,6

6,6

6,4

20,46

29,59

40,35

53,06

72,59

99,50

143,90

196,23

242,02

287,81

392,47

484,04

580,74

709,80

967,91

1161,49

1419,60

1,8

1,8

1,8

1,9

2,0

2,0

2,0

2,0

1,9

1,9

1,9

1,9

1,8

1,8

1,8

1,8

1,8

2

3

4

5,5

7,5

10

15

20

25

30

40

50

60

75

100

125

150

2,0

2,0

2,0

2,0

2,0

2,0

2,0

2,0

2,0

2,0

2,0

2,0

2,0

2,0

2,0

2,0

2,0

77,2

81,9

83,0

86,0

86,6

87,2

87,8

88,2

91,3

90,0

92,4

92,5

92,6

93,0

93,5

93,7

94,1

77,3

82,2

83,4

85,8

87,3

88,1

87,9

88,7

91,5

90,7

92,3

92,4

92,6

93,0

93,5

93,5

94,5

0,69

0,72

0,74

0,74

0,77

0,79

0,77

0,77

0,76

0,78

0,81

0,78

0,78

0,82

0,82

0,82

0,83

0,60

0,66

0,67

0,64

0,71

0,74

0,70

0,70

0,72

0,75

0,76

0,73

0,73

0,76

0,78

0,78

0,80

61

64

64

68

68

68

70

73

73

73

75

76

76

82

82

82

82

28

45

55

105

78

90

160

235

242

285

390

500

580

790

970

1055

1118

0,02450

0,03140

0,03950

0,07530

0,09310

0,12600

0,20300

0,33900

0,49100

0,54700

0,84300

1,93000

1,65000

4,79000

5,58000

6,37000

7,23000

8 Poles asynchronous speed 750 rpm

PowerKW

PowerHP Type rpm

CurrentIs/In

TorqueCn (Nm)

TorqueCs/Cn

TorqueCmax/Cn

Efficiency η100% 75%

CurrentIn (A)

Pwr. Fact. cosϕ100% 75%

LwA

(dB)

J

Kgm2Kg

Page 24: REV.0 GENERAL CATALOGUE - Emco Engineers

��

��

��

��

tipi 180 - 355

24

COMPONENTS LIST

1

2

3

4

5

6

7

8

9

10

11

12

13

CODE

3PNSTA

3PNROT

3PNFRA

3PNFBE

3PNBBE

3PNFOS

3PNBOS

3PNBSH

3PNB03

3PNB05

3PNB14

3PNFEE

3PNWAV

14

15

16

17

18

19

20

21

22

23

24

25

26

CODE

3PNFAN

3PNFCV

3PNUCB

3PNTER

3PNBCB

3PNCMP

3PNCAP

3PNSCB

3PNCCB

3PNFOB

3PNFIB

3PNBIB

3PNBOB

types 180 - 355

Page 25: REV.0 GENERAL CATALOGUE - Emco Engineers

25

RUBBER SEAL RINGS AND BEARINGS

FRAME POLES SIZE NUMBER

56-63 2 - 8 12x25x7 12x25x7 6201 620171 2 - 8 15x30x7 15x30x7 6202 620280 2 - 8 20x35x7 20x35x7 6204 620490 2 - 8 25x40x7 25x40x7 6205 6205100 2 - 8 30x47x7 30x47x7 6206 6206112 2 - 8 30x47x7 30x47x7 6206 6206132 2 - 8 40x62x7 40x62x7 6208 6208160 2 45x62x12 45x62x12 6209 6209160 4 - 8 45x62x12 45x62x12 6309 6309180 2 55x75x12 55x75x12 6211 6211180 4 - 8 55x75x12 55x75x12 6311 6211200 2 60x80x12 60x80x12 6212 6212200 4 - 8 60x80x12 60x80x12 6312 6212225 2 65x90x12 65x90x12 6312 6312225 4 - 8 65x90x12 65x90x12 6313 6312250 2 70x90x12 70x90x12 6313 6313250 4 - 8 70x90x12 70x90x12 6314 6313280 2 80x110x12 80x110x12 6314 6314280 4 - 8 80x110x12 80x110x12 6317 6314315 2 95x120x12 95x120x12 6316 6316315 4 - 8 95x120x12 95x120x12 NU 319 6319355 2 95x120x12 95x120x12 NU 319 6319355 4 8 95x120x12 95x12x12 NU 322 NU 322

� �RUBBER SEAL RING BEARINGS

2 bearings lubricationdevices on the front andthe back shield areprovided in motors fromsize 180 and up.Other motors mountstaunch bearings pre-lubricated for life

Page 26: REV.0 GENERAL CATALOGUE - Emco Engineers

26

ALL DATA HAVE BEEN WRITTEN AND CHECKED WITH THE GREATEST CARE.WE DO NOT TAKE ANY RESPONSIBILITY FOR POSSIBLE ERRORS OR OMISSIONS.MOTIVE CAN CHANGE THE CHARACTERISTICS OF THE SOLD ITEMS ON HIS FIRM OPINIONAND IN EVERY MOMENT.

TERMS OF SALE AND GUARANTEE

ARTICLE 4PAYMENT

4.1. Any delayed or irregular paymentsshall entitle Motive to cancel ongoingagreements, including agreements whichdo not regard the payments at issue, aswell as entitling Motive to claim damages,if any. Motive shall, however, have theright, as of the payment’s due date andwithout placing in arrears, to claim interestfor arrears, to the extent of the discountrate in force in Italy, increased by 5 points.Motive shall also have the right to withholdmaterial under repair for replacement.In the case of failed payment, Motive shallhave the right to cancel all guaranteeson materials, as regards the insolventClient.

4.2. The Buyer shall be bound to completepayment, including cases whereby claimsor disputes are underway.

ARTICLE 2CLAIMS

2.1. Without prejudice to the applicationof provisions in Law, dated June 21,1971, and as per Article 1:Claims, regarding quantity, weight, grossweight and colour, or claims regardingfaults and defects in quality or compliance,and which the Buyer may discover ongoods delivery, shall be submitted by amax. 7 days of aforesaid discovery, underpenalty of nullity.

ARTICLE 3DELIVERY

3.1. Any liability for damages ensuingfrom total or partial delayed or faileddelivery, shall be excluded.

3.2. Unless differently communicated bywritten to the Client, the transport termshave to be intended ex-works

The guarantee shall be subject to specificwritten request for Motive to takeaction,according to statements, as describedat the paragraphs hereinbelow.By virtue ofaforesaid approval, and as regards the claim,Motive shall be bound, at its discretion, andwithin a reasonable time-limit, to alternativelytake the following action:

a) To supply the Buyer with products of thesame type and quality as those havingproven defective and not complying withagreements, free ex-works; in aforesaidcase, Motive shall have the right to request,at the Buyer’s charge, early return ofdefective goods, which shall becomeMotive’s property;

b) To repair, at its charge, the defectiveproduct or to modify the product whichdoes not comply with agreements, byperforming aforesaid action at its facilities;in aforesaid cases, all costs regardingproduct transport shall be sustained bythe Buyer.

c) To send spare parts free of charge: allcosts regarding product transport shallbe sustained by the Buyer.

1.3 The guarantee herein shall assimilateand replace legal guarantees for defects anddiscrepancies, and shall exclude any othereventual Motive liability, however caused bysupplied products; in particular, the Buyershall have no right to submit any furtherclaims.Motive shall not be liable for the enforcementof any further claims, as of the date theguarantee ’s term of validity expires.

ARTICLE 1GARANTEE

1.1. Barring written agreements, enteredinto between the parties hereto each time,Motive hereby guarantees compliance ofproducts supplied and compliance withspecific agreements.The guarantee for defects shall be restrictedto product defects following design, materialsor manufacturing defects leading back toMotive.

The Guarantee shall not include:

faults or damages ensuing fromtransport., faults or damages ensuingfrom installation defects; incompetentuse of theproduct, or any otherunsuitable use.

tampering or damages ensuing from useby non-authorised staff and/or use of non-original parts and/or spare parts;

Defects and/or damages ensuing fromchemical agents and/or atmosphericphenomena (e.g. burnt out material, etc.); routine maintenance and required actionor checks;

Products lacking a plate or having a tampered plate.

1.2. Returns to credit or replace will beaccepted only in exceptional cases;However returns of goods already usedto credit or replace won’t be accepted inany case.The guarantee shall be effective for allMotiveproducts, with a term of validity of 12months, starting from the date ofshipment.

Page 27: REV.0 GENERAL CATALOGUE - Emco Engineers

motive wishes to thank the following for their help in preparing this catalogue:Studio Grafico Immagine (Brescia)In Immaginabile studio fotografico (Brescia)

Page 28: REV.0 GENERAL CATALOGUE - Emco Engineers

Motive s.r.l.

Via G. D’Annunzio, 11 - 25018 MONTICHIARI (BS) - Italy

Tel. +39.030.9962342 - Fax +39.030.962011

web site: www.motive.it - e-mail: [email protected]

GEN

ERAL

CATA

LOG

UE

DEL

PH

ISER

IES

04

09

REV

.0

AREA DISTRIBUTOR

®