GENERAL CATALOGUE DELPHI SERIES 04 09 REV.0 GENERAL CATALOGUE DELPHI SERIES ASYNCHRONOUS THREE-PHASE ELECTRIC MOTORS ®
GEN
ERAL
CATA
LOG
UE
DEL
PH
I SER
IES 0
4 0
9 R
EV.0
G E N E R A L C A T A L O G U EDELPHI SERIES ASYNCHRONOUS THREE-PHASE ELECTRIC MOTORS
®
®
INDEX
Technical characteristics pag. 4-5
Efficiency pag. 6CE Marking pag. 7Delphi EX
Protection TypeDuty Service pag. 8Working conditions pag. 9Assisted power cooling
Motive motors protection pag. 10
Three-phase self-brakingmotors series atdc delphi pag. 11
Delphi ATDC pag. 12
Brake description pag. 13Brake operationAdjustment
Wiring diagrams pag. 14
Motor configurations and pag. 15installation positions
Table of dimensions pag. 16-17
Technical data pag. 18-19
Technical data pag. 20-21
Technical data pag. 22-23
Component list pag. 24
Rubber seal ringsand bearings pag. 25
Terms of saleand guarantee pag. 26
4
TECHNICAL CHARACTERISTICS
Motive motors are built according tointernational standard regulations; eachsize throughout the construction formsis calculated with reference to the tablesof standard IEC 72-1.
The shapes built per IEC 34-7, are B3,B5, B14, B35.
Motive asynchronous three-phase Delphiseries motors are closed, and externallyventilated.The frame, up to 132 included, is madein die casting aluminium alloy, from size160 up to 355 the frame is made in castiron.
All motors aremultiple voltagemulti-frequency 50/60Hz,F class insulation,S1 continuous duty service,IP55 protection1 or 2 efficiency classtropicalized.
motive motors adopt only bearings selected fortheir silence and reliability and, for the sameobjectives, the cage rotor is dynamically balancedaccording to IEC 34-14 and ISO 9921 norms
Blocking the bearings intotheir slots with snap ringsprevents them frommoving axially. From type90, a steel insert isprovided in the bearing slotof the aluminum flanges,to res is t to rad ia lmechanical forces with afair degree of security
The copper is impregnated with adouble layer of H class insulatingenamel to ensure high resistanceto e lectr ica l , thermal andmechanical stress.The phases are further isolated byanother layer of Nomex film toprotect the motors from the voltagepeaks that usually occur when themotor is controlled by an inverter.
PATENTED
5
Aiming the maximumprotection, the motorsare equipped withimportant details like thepull-resistant cable pressand the combination ofbearings with two shieldseach with rubber sealrings
Performance excellence is granted by theFeV magnetic lamination sheets adoption,instead then the usual normal FeP01,FeV lamination sheets provide higherefficiency, lower heating, energy savingand longer life to isolation materials
To protect them by the rust,motive motors are painted ins i l ver RAL9006 colour
Feet and connectionbox can be movedto the right or left
Cable press can beeasily moved on both thesides of the connectionbox, thanks to the screwcap
the connectionbox can berotated of 360°with steps of 90°
70
75
80
85
90
95
1 10 100
PN/kW
%
ηN
4 p
2 p
6
There are no requestsabout minimum efficiency,but it is defined clearlywhich are the motorsclassified efficiency 1, 2and 3.Motive has organized itsproduction respecting theparameters indicated bythe new Europeanclassification.Client’s benefits are ofmany kinds
The European Agreement issued by the European Commission and CEMEP (European Committee of Manufacturers of Electrical Machines and Power Electronics), establishes a newclassification system of electric motors based on the efficiency. The reference values are shown by the attached diagram and the following paragraph.
EFFICIENCY
BILL EFFECTSBill effects are the first to be inevidence. The calculation changesd e p e n d i n g b y t h e u s ecircumstances, but we can saythat efficiency 2 motors allow asaving of about 20%. For instance,a 15kW motor, for an operationperiod of 6.000 hours per year,can save about 2 MWh/a ormore: about 100 Euro of yearlyoperation costs
DURABILITY EFFECTSHigher efficiency motors heat less,slowing down the aging cycle of theinsulating materials and living longer.Average operating life of Eff.2 Motivemotors is:2500 hours/ year for motors upto 15kW4000 hours/year for bigger motorsThe average life is approximatelyfrom 25 to 30.000 hours for thefirst and 50,000 for the secondones
AMBIENT EFFECTSEfficiency 2 motors guaranteegreat energy and money savings,with an objective of sustainabledevelopment, reduction of CO2emissions and consequentimprovement of the quality of theatmosphere
HOW TO MAKE A MORE EFFICIENTMOTOR?High efficiency can be seen in manyways: like the relation betweenoutput power and input absorbedpower, or like a measure of thelosses that born when convertingthe electric power in mechanicalenergy.From another perspective, highefficiency motors consume lessenergy to produce the same torque
Motors 2 poles
kWefficiency
eff3 eff2 eff1
1.1 <76.2 ≥76.2 >82.8
1.5 <78.5 ≥78.5 >84.1
2.2 <81.0 ≥81.0 >85.6
3 <82.6 ≥82.6 >86.7
4 <84.2 ≥84.2 >87.6
5.5 <85.7 ≥85.7 >88.6
7.5 <87.0 ≥87.0 >89.5
11 <88.4 ≥88.4 >90.5
15 <89.4 ≥89.4 >91.3
18.5 <90.0 ≥90.0 >91.8
22 <90.5 ≥90.5 >92.2
30 <91.4 ≥91.4 >92.9
37 <92.0 ≥92.0 >93.3
45 <92.5 ≥92.5 >93.7
55 <93.0 ≥93.0 >94.0
75 <93.6 ≥93.6 >94.6
90 <93.9 ≥93.9 >95.0
Motors 2 poles
kWefficiency
eff3 eff2 eff1
1.1 <76.2 ≥76.2 >83.8
1.5 <78.5 ≥78.5 >85.0
2.2 <81.0 ≥81.0 >86.4
3 <82.6 ≥82.6 >87.4
4 <84.2 ≥84.2 >88.3
5.5 <85.7 ≥85.7 >89.2
7.5 <87.0 ≥87.0 >90.1
11 <88.4 ≥88.4 >91.0
15 <89.4 ≥89.4 >91.8
18.5 <90.0 ≥90.0 >92.2
22 <90.5 ≥90.5 >92.6
30 <91.4 ≥91.4 >93.2
37 <92.0 ≥92.0 >93.6
45 <92.5 ≥92.5 >93.9
55 <93.0 ≥93.0 >94.2
75 <93.6 ≥93.6 >94.7
90 <93.9 ≥93.9 >95.0
EURO W/ Kg W/ KgNORM a 1T a 1,5T
106- 84 1,70 4,00
data at 400V 50Hz
Instead, no standard prescribes amaximum loosing factor for Fe P01lamination sheets; although we cansay that generally this is at leastthe double of FeV laminationsheets,not even this data can beguaranteed. This is a source ofpotential performance diversitiesbetween motor and motor.
The reason of a longer life is basedon the lower heating that lengthensthe ageing cycle of the insulationmaterials.
Between all the raw materials thatcompose an asynchronous electricmotor, lamination sheets iron ist h e m a i n p e r f o r m a n c ediscriminating factor.
The main advantages given by theadoption of silicon magneticlaminations are:• higher efficiency• better guarantees on the quality
constancy, assured bytolerances reported ininternational norms
on the shaft. Basically, an highefficiency motor is the result ofprecise workings, lower frictions,a dynamically balanced rotor,smaller space between rotor andstator and of the use of bettermaterials. The main factors forthe design are based on the choiceof the type of lamination sheetsand windings with a greater coilnumber and a bigger diameterwire..Among all materials that composea motor, laminations have thehighest influence on performance
SILICON MAGNETIC LAMINATIONSMotive motors are made with FeVmagnetic lamination sheets, ratherthan the customary normal Fe P01iron lamination sheets.
Further than raw material, thesheets thickness is anotherperformance source.In fact, the thinner is the sheet,the higher are the performances.
The lamination sheets Fe P01can reach up to 1mm thickness.
FeV magnetic lamination sheetshave a 0,5mm max imumthickness.
Composition and thickness give tomagnetic lamination sheets a verylow W/Kg loosing factor:
Lower specific losses mean lessmagnetising current for the samePower and torque (thus lessheating).
7
II 3 D
In order to meet the safety concerns in dust-filledatmospheres, the Delphi series motors are alsoavailable, upon request, in the version Delphi Ex.Conforming to the Essential safety requirement of theATEX 94/9/EC European Directive (ATEX 95), thesemotors have been designed to operate in the zone 22(Group II Category 3 D Tmax surf. 125°C).
Their “Ex” marking refers to the following norms:
Community Low Voltage Directive(LVD) 73/23 EEC, modified by theCommunity Directive regardingmarking 93/68 EEC
Community ElectromagneticCompatibility Directive (EMC) 89/336EEC and its modifications 91/263EEC, 92/31 EEC e 93/68 EEC
Community Machinery Directive (MD)89/392 EEC and its modifications91/368 EEC, 93/44 EEC e 93/68EEC
CE marking is put by Motive as avisible sign of the product compliancewith the requirements of abovementioned directives. In order to reachthis conformity, Motive productsrespect the following productstandards:
EN 60034-1 (last issue). Rotatingelectrical machines. Part 1: ratingand performance
EN 60034-5 (last issue). Rotatingelectrical machines. Part 5:classification of degrees of protection
EN 60034-6 (lasti issue). Rotatingelectrical machines. Part 6:methods of cooling (IC code)
EN 60034-9 (last issue). Rotatingelectrical machines. Part 9: noiselimits
EN 50081-1 (last issue).Electromagnetic compatibility- Generic emission standard- Part 1: residential and lightindustry environment
marking is referred to:
CE MARKING SERIE DELPHI EX
CEI EN 50281-1-1CEI EN 50281-1-1/A1
1999-112002-10
Electrical apparatus for use in thepresence of combustible dustPart 1-1: Electrical apparatusprotected by enclosures – Constructionand testing
CEI EN 50281-2-1 1999-11Electrical apparatus for use in thepresence of combustible dust.Part 2-1: Test methods – Methodsfor determining the minimum ignitiontemperatures of dust
CEI EN 50281-1-2 1999-09Electrical apparatus for use in thepresence of combustible dustPart 1-2: Electrical apparatusprotected by enclosuresSelection, installation and maintenance
CEI EN 50014CEI EN 50014/A1/A2
1998-061999-08
Electrical apparatus for potentiallyexplosive atmospheres.General requirements
EN 50082-1 ( last issue).Electromagnetic compatibility - Genericimmunity standard - Part 1: residentialand light industy environment
EN 50081-2 ( last issue).Electromagnetic compatibility - Genericemission standard - Part 2: Industrialenvironment
EN 50082-2 ( last issue).Electromagnetic compatibility - Genericimmunitystandard - Part 2: Industrialenvironment
N
a
b
c
d
Tmax
8
* OPTIONAL
DUTY SERVICE
All Motive motors shown in this catalogueare made for S1 continuous duty service,as per IEC 34-1 norm. The duty serviceclass is shown on the rating plate.Below are described the various types ofservice:
S1 - Continuous service:operating at constant load of durationN in order to reach a thermal balance.
S2 Limited-duration service: operating atconstant load of duration N, less thanthe time necessary to reach a thermalbalance followed by a rest periodsufficient in order to restore the balancebetween the machine temperature andthat of the cooling fluid, with a toleranceof 2° C.
S3 Periodic intermittent service:sequence of identical operating cycles,each including a period of operation atconstant load N and a rest period R.In this type of service, the cycles issuch that start-up does not significantlyaffect the peak temperature.
S4 - Periodic intermittent service with start-up: sequence of identical operatingcycles, each including a substantial start-up stage D, a constant-load operatingperiod N and a rest period R.
S5 - Periodic intermittent service with electricbraking: sequence of operating cyclesas for S4, with the addition of a rapidelectric braking F.
S6 Uninterrupted periodic service withintermittent load: sequence of identicaloperating cycles, each including aconstant load operating period N anda no-load period V.No rest time is included
S7 Uninterrupted periodic service withelectric braking: sequence of operatingcycles as for S5, but without a restperiod
S8 Uninterrupted periodic service withcorrelated load and velocity variations:sequence of identical operating cycles,each of which includes a constant-loadoperating period N corresponding to apre-set rotation speed, followed by oneor more operating periods with otherconstant loads N2, N3, et.,corresponding to different rotationspeeds. There is no rest period.
S9 Service with non-periodic variations inload and speed: service in which theload and speed generally vary in a non-periodic fashion within the admissibleoperating field. This service includesfrequently applied overloads which maybe greatly superior to the full load.
0
1
2
3
4
5
6
no protection
protection againstsolid corps biggerthan 50mm
protection againstsolid corps biggerthan 12mm
protection againstsolid corps biggerthan a 2,5mm
protection againstsolid corps biggerthan 1 mm
protection againstharmful dustdeposits
complete protectionagainst the totalpenetration of dust*
no protection
protection againstvertical water drops
protection againstwater drops fall upto 15° of inclination
protection againstwater drops up to60° of inclination
protection againstwater sprayed byall directions
protection against waterlaunched by a nozzle of6,3mm D with a watercapacity 12,5lt/min at adistance of maximum 3mt for 3 min
protection against waterprojections similar to seawaves*
1° number 2° number
The protection against people accidentalcontacts and/or the entry of corps and/orthe entry of water is expressed at internationallevel (EN60529) by a symbolic acronymcomposed by a group of 2 letters and 2numbers.
IP index of protection reference letters
1° num. Protection of people against contactsand protection against the entry of solid corps
2° num. Protection against harmful entry ofwater
Motive motors are IP55 protected
PROTECTION TYPE
*
a = loadb = electric lossesc = temperatured = timeN = steady load operating timeTmax= max temperature achieved
RAIN SHIELDFor outdoor applications with V5 - V18 - V1 - V15installation, we recommend to mount a rain shield.This configuration may also be used in textilesprocessing industry.
TYPE63718090S90L100112132S132M160M160L180M180L200L225S225M250M280S280M315S315M315L355M355L
L215323369403428469453573613770825915955
10251155116012201265131515401570168018401870
3
9
WORKING CONDITIONS
HUMIDITY:The electrical equipment must be able towork with a relative humidity between 30and 95% (without condensation).Damaging effects of occasional condensationmust be avoided by adequate equipmentdesign or, if necessary, by additional measures(for example, built-in heating or air-conditioningequipment, drainage holes).
ALTITUDE AND TEMPERATURE:the powers indicated are intended for regularuse at altitudes below 1000 mt above sealevel and a room temperature between +5°Cand +40°C for motors having a rated powerbelow 0.6 kW, or between -15°C and 40°Cfor motors having a rated power equal toor greater than 0.6 kW (IEC 34-1): Forworking conditionsrather than those specified (higher altitudeand/or temperature) the power decreasesof 10% each 10°C of higher temperature,and of 8% for each 1000 mt of higheraltitude.It is not necessary to reduce the rated powerif at an altitude higher than 1000mt andlower than 2000mt there is a max ambienttemperature of 30°C or, in altitudes from2000 mt to 3000mt there is a max ambienttemperature of 19°C.
VOLTAGE - FREQUENCY:The maximum variation of the supply voltageis +-10%.Within this tolerance Motive motors supplythe rated power.
Classe ∆T (°C) Tmax (°C)
A 60+5° 105
E 75+5° 120
B 80+5 130
F 105+5° 155
H 125 180
INSULATION:The copper is impregnated with a doublelayer of H class insulating enamel to ensurehigh resistance to electrical, thermal andmechanical stress.A NOMEX*/D.M./D.M.D./N.M./N.M.N./M. film that wraps entirely around the coilside insulates the copper and iron from oneanother.The phases are further isolated by anotherlayer of NOMEX*/D.M./D.M.D./N.M./N.M.N./M. to protect the motors fromvoltage peaks that usually occur when themotor is controlled by inverter.Below is a graph showing the operatingtemperatures possible for stator windingsbased on the insulation rating shown onthe machine plate
Motive motors are designed to not to passthe max temperatures of their class evenunder S1 continuous duty service.
ASSISTED POWER COOLING
For applications with a power supply below a frequency of50Hz, the appropriate assisted power cooling must bemounted as there are too many variables involved to determinethe various possible thermal duties, and thus the temperaturesreached by the motors
three-phase 400/50 400/60, IP 55, with separate terminal box
ENCODER
motors with encoder or special shaft configurations for encoder mounting are available uponrequest. In this case, assisted power cooling is also available, supported by brackets on thefan cover
TYPE
718090S90L100112132S132M160M160L180M180L200L225S225M250M280S280M315S315M315L355M355L
POWERW30355050656590909090
100100180200200320370370500500500600600
CAPACITYm3/h300350500500650
1000880880
110011001200120025003800380042005000500060006000600065006500
LSIZE320366400425466450570610710765805845910
1035104011101160121014101440155017151745
10
MOTIVE MOTORS PROTECTION
protections must be chosen based on thespecific running conditions, according tostandards EN 60204-1.
Protection for motors with a shaft powergreater than or equal to 0.5 kW withcontinuous S1 service. This protectionmay be achieved by means of a thermalcut-out relay, which automatically controla knife switch.
Protection against peak currents bymagnetic relay that controls an automaticknife switch, or by fuses; these must beset to the locked rotor current.
If the application requires, protectionagainst excessive speed of the electricmotor, for example if the mechanicalload may drive the electric motor itselfand thereby create a hazardous situation.
If special conditions or synchronisedoperation with other machines or partsof machines require it, protection againstpower failures or dips by means of aminimum voltage relay that controls anautomat ic power kni fe switch.
The electrical protections on the motorpower line may not be sufficient to protectagainst overloads. If the cooling conditionsworsen, the motor overheats but theelectrical conditions do not change, whichinhibits line protections. Installing built-inprotections on the windings solvesthis problem:
PTO bimetallic devicethis is a normally-closed electromechanicaldevice that opens electrically when thethreshold temperature is reached; itautomatically resets when the temperaturefalls below the threshold level. Bimetallicdevices are available with variousintervention temperatures and withoutautomatic reset, per EN 60204-1.
PTC thermistor devicethis device promptly, positively adjustsits resistance once the thresholdtemperature is reached. Motivemotors from type 160 to type 355Lare equipped with 3 PTC thermistorsin the winding, with temperatureintervention of 150°C in Class Fmotors (standard), or 180°C in HClass motors.
PT100 devicethis is a device that continuously,increasingly adjusts its resistanceaccording to the temperature. It is usefulfor constant measuring of thewinding temperatures using electronicequipment.
THREE-PHASE SELF-BRAKING MOTORS SERIES DELPHI ATDC
12
DELPHI ATDCKW HP
Brakingtorquefull-load
Nm
Brakingtorqueno-load
sec
0,18
0,25
0,37
0,55
0,75
1,1
1,5
2,2
3
4
5,5
7,5
11
15
18,5
0,12
0,18
0,25
0,37
0,55
0,75
1,1
1,5
2,2
3
4
5,5
7,5
11
15
0,37
0,55
0,75
1,1
1,5
2,2
3
4
5,5
7,5
11
ATDC 63A-2
ATDC 63B-2
ATDC 71A-2
ATDC 71B-2
ATDC 80A-2
ATDC 80B-2
ATDC 90S-2
ATDC 90L-2
ATDC 100L-2
ATDC 112M-2
ATDC 132SA-2
ATDC 132SB-2
ATDC 160MA-2
ATDC 160MB-2
ATDC 160L-2
ATDC 63A-4
ATDC 63B-4
ATDC 71A-4
ATDC 71B-4
ATDC 80A-4
ATDC 80B-4
ATDC 90S-4
ATDC 90L-4
ATDC 100LA-4
ATDC 100LB-4
ATDC 112M-4
ATDC 132S-4
ATDC 132M-4
ATDC 160M-4
ATDC 160L-4
ATDC 80A-6
ATDC 80B-6
ATDC 90S-6
ATDC 90L-6
ATDC 100L-6
ATDC 112M-6
ATDC 132S-6
ATDC 132MA-6
ATDC 132MB-6
ATDC 160M-6
ATDC 160L-6
4,0
4,0
4,0
4,0
7,5
7,5
15,0
15,0
30,0
40,0
75,0
75,0
150,0
150,0
150,0
4,0
4,0
4,0
4,0
7,5
7,5
15,0
15,0
30,0
30,0
40,0
75,0
75,0
150,0
150,0
7,5
7,5
15,0
15,0
30,0
40,0
75,0
75,0
75,0
150,0
150,0
0,15
0,15
0,15
0,15
0,20
0,20
0,25
0,25
0,30
0,35
0,40
0,40
0,50
0,50
0,50
0,15
0,15
0,15
0,15
0,20
0,20
0,25
0,25
0,30
0,30
0,35
0,40
0,40
0,50
0,50
0,20
0,20
0,25
0,25
0,30
0,35
0,40
0,40
0,40
0,50
0,50
25
25
25
25
50
50
60
60
80
110
130
130
150
150
150
25
25
25
25
50
50
60
60
80
80
110
130
130
150
150
50
50
60
60
80
110
130
130
150
150
150
7,8
8,1
9,0
9,5
12,7
13,5
16,3
18,0
27,0
37,0
49,1
54,5
84,2
93,0
103,5
7,8
8,1
9,0
9,5
13,4
14,8
16,5
18,3
26,8
29,5
37,5
51,5
57,5
87,5
100,6
12,9
14,4
16,6
18,2
29,0
36,2
50,2
53,0
57,2
85,6
90,0
0,25
0,35
0,5
0,75
1
1,5
2
3
4
5,5
7,5
10
15
20
25
0,18
0,25
0,35
0,5
0,75
1
1,5
2
3
4
5,5
7,5
10
15
20
0,5
0,75
1
1,5
2
3
4
5,5
7,5
10
15
TypeBrake input
powerW
Kg
TYPE L
ATDC 63ATDC 71ATDC 80ATDC 90SATDC 90LATDC 100LATDC 112MATDC 132SATDC 132MATDC 160MATDC 160L
240270375400426465495570610715760
Delphi ATDC series self-braking motors use spring-pressure brakes, firmly spliced ontoa cast iron shield at the back of the motor.These motors include a series of characteristics normally considered options by otherbrands, like:The hand release lever permits to release the brake, making it possible to move theshaft.The separate brake power supply is achieved, whenever needed, by connecting directlyto the brake terminal board located inside the motor terminal box.The PTO thermal protectors in the winding
� �
�
�
�
� �
S �
�
�
�
�� �
13
BRAKE DESCRIPTION BRAKE OPERATION ADJUSTMENT
Mobile armature
springs
Brake disc
Driver
Motor shaft
Motor flange
Electromagnet
Release lever
Adjuster screws
Threaded bush
Air gap
�
�
�
�
�
�
�
�
S
�
�
�
�
�
�
�
�
S
The adjustment is made by using thethreaded bushes �, using a thicknessgauge to make sure that the wished airgap is reached.
Braking torque adjustmentThe braking torque can be increased by tightening the adjuster screws �. The settinghas already been made by motive at the max value, and therefore we suggest to notto intervene on it.
Two different types of adjustment are possible
S air gap adjustmentFor proper operation, the air gap S between electromagnet and the mobile armature� must be between the following indicated limits:
When the power supply is interrupted, theexcitation coil is no longer powered andtherefore doesn’t exert the magnetic forcenecessary to restrain the mobile armature�, hwich, pushed by the pressure springs�, compresses the brake disk � againstthe motor flange � on one side and thearmature itself on the other, thereby creatinga braking action.
The Delphi ATDC series brake is anelectromagnetic brake with negativeoperation, whose braking action is exercisedin the absence of power supply.The brake insulation class is F.The brake lining is asbestos-free, as permost recent EEC Directives in terms ofWorkplace Hygiene and Safety.All brake assemblies are protected againstcorrosion by painting and/or heatgalvanizing. The parts most subject to wearare treated in special atmospheres thatprovide considerable wear resistance tothe parts.The standard supply voltage of the brakeis 230V±10% 50/60Hz on the AC of the brakepower pack
Mobile armature
springs
Brake disc
Driver
Motor shaft
Motor flange
Electromagnet
Release lever
Adjuster screws
Threaded bush
Air gap
MOTOR TYPE S AIR GAP (mm)
63˜71 0.40˜0.50
80˜160 0.50˜0.60
14
DELTA CONNECTIONDelta connection is obtained by connecting the end of aphase with the beginning of the following one.The phase current Iph and the phase voltage Uph arerepectively:Iph = In / 3 -2Uph = Unwhere In and Un are referred to Delta connection.
WIRING DIAGRAMS
Motive three phase motors can be connected “Star” or “Delta”.
STAR CONNECTIONStar connection is obtained by connecting together theterminals W2, U2, V2 and supplying the terminalsU1, V1, W1.The phase current and voltage are respectively:Iph = InUph = Un / 3 -2where In is the supply line current and Un is the supplyline voltage of Star connection
the fo l lowing vo l tages andfrequencies are inside the standardpower supply of all three-phasemotive motors, under S1 dutyservice:
Size
Volts
50
60
56-132
400
380
415
440
460
480
Hz
690
660
720
760
795
830
50
60
132-355
230
220
240
260
265
280
400
380
415
440
460
480
IM1051 (IM B6) IM1001 (IM B3)
IM1071 (IM B8) IM1031 (IM V6)
IM1061 (IM B7) IM1011 (IM V5)
IM2001 (IM B35) IM2101 (IM B34)
B3/B5 B3/B14
IM3001 (IM B5)
IM3011 (IM V1)
IM3031 (IM V3)
IM2011 (IM V15)
V1/V5
IM3601 (IM B14)
IM3611 (IM V18)
IM3631 (IM V19)
IM2031 (IM V36)
V3/V6
15
FLANGE-MOUNTEDMOTORS B14
FLANGE-MOUNTEDMOTORS B5
MOTORS WITHFEET B3
CONSTRUCTION FORMS AND SIZE TABLES
MOTOR CONFIGURATIONS AND INSTALLATION POSITIONS (IEC 34-7)
16
B3
56
63
71
80
90S
90L
100
112M
132S
132M
160M
160L
180M
180L
200L
225S
225M
225M
250M
250M
280S
280S
280M
280M
315S
315S
315M
315M
315L
315L
355M
355M
355L
355L
2-8
2-8
2-8
2-8
2-8
2-8
2-8
2-8
2-8
2-8
2-8
2-8
2-8
2-8
2-8
4-8
2
4-8
2
4-8
2
4-8
2
4-8
2
4-8
2
4-8
2
4-8
2
4-8
2
4-8
120
130
145
175
195
195
215
240
275
275
330
330
380
380
420
470
470
470
510
510
580
580
580
580
645
645
645
645
645
645
710
710
710
710
102
114
119
130
145
145
170
177
197
197
255
255
280
280
305
335
335
335
370
370
410
410
410
410
530
530
530
530
530
530
655
655
655
655
56
63
71
80
90
90
100
112
132
132
160
160
180
180
200
225
225
225
250
250
280
280
280
280
315
315
315
315
315
315
355
355
355
355
M16
M20
M20
M20
M20
M20
M20
M25
2xM32
2xM32
2xM40
2xM40
2xM40
2xM40
2xM50
2xM50
2xM50
2xM50
2xM63
2xM63
2xM63
2xM63
2xM63
2xM63
2xM63
2xM63
2xM63
2xM63
2xM63
2xM63
2xM63
2xM63
2xM63
2xM63
164
212
240
276
305
330
371
380
455
495
615
670
700
740
770
815
820
845
910
910
985
985
1035
1035
1160
1270
1190
1300
1190
1300
1500
1530
1500
1530
9
11
14
19
24
24
28
28
38
38
42
42
48
48
55
60
55
60
60
65
65
75
65
75
65
80
65
80
65
80
75
95
75
95
M4x12
M4x12
M5X12
M6X16
M8X19
M8X19
M10X22
M10X22
M12X28
M12X28
M16X36
M16X36
M16X36
M16X36
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
20
23
30
40
50
50
60
60
80
80
110
110
110
110
110
140
110
140
140
140
140
140
140
140
140
170
140
170
140
170
140
170
140
170
3
4
5
6
8
8
8
8
10
10
12
12
14
14
16
18
16
18
18
18
18
20
18
20
18
22
18
22
18
22
20
25
20
25
7,2
8,5
11,0
15,5
20,0
20,0
24,0
24,0
33,0
33,0
37,0
37,0
42,5
42,5
49,0
53,0
53,0
56,0
56,0
67,5
58,0
67,5
58,0
71,0
58,0
71,0
58,0
71,0
58,0
71,0
67,5
86,0
67,5
86,0
111
123
138
157
173
173
196
227
262
262
320
320
355
355
395
435
435
435
490
490
550
550
550
550
635
635
635
635
635
635
730
730
730
730
71
80
90
100
100
125
140
140
140
178
210
254
241
279
305
286
311
311
349
349
368
368
419
419
406
406
457
457
508
508
500
500
630
630
36
40
45
50
56
56
63
70
89
89
108
108
121
121
133
149
149
149
168
168
190
190
190
190
216
216
216
216
216
216
254
254
254
254
5,8
7
7
10
10
10
12
12
12
12
15
15
15
15
19
19
19
19
24
24
24
24
24
24
28
28
28
28
28
28
28
28
28
28
90
100
112
125
140
140
160
190
216
216
254
254
279
279
318
356
356
356
406
406
457
457
457
457
508
508
508
508
508
508
610
610
610
610
80
95
110
130
130
130
180
180
230
230
250
250
250
250
300
350
350
350
450
450
450
450
450
450
550
550
550
550
550
550
680
680
680
680
120
140
160
200
200
200
250
250
300
300
350
350
350
350
400
450
450
450
550
550
550
550
550
550
660
660
660
660
660
660
800
800
800
800
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
7
10
10
12
12
12
15
15
15
15
19
19
19
19
19
19
19
19
19
19
19
19
19
19
24
24
24
24
24
24
24
24
24
24
3
3
3,5
3,5
3,5
3,5
4
4
4
4
5
5
5
5
5
5
5
5
5
5
5
5
5
5
6
6
6
6
6
6
6
6
6
6
65
75
85
100
115
115
130
130
165
165
215
215
50
60
70
80
95
95
110
110
130
130
180
180
80
90
105
120
140
140
160
160
200
200
250
250
0
0
0
0
0
0
0
0
0
0
0
0
M5
M5
M6
M6
M8
M8
M8
M8
M10
M10
M12
M12
2,5
2,5
2,5
3,0
3,0
3,0
3,5
3,5
3,5
3,5
4,0
4,0
100
115
130
165
165
165
215
215
265
265
300
300
300
300
350
400
400
400
500
500
500
500
500
500
600
600
600
600
600
600
740
740
740
740
TYPE POLES AC AD H KK L D DH E F G A AB B C K M N P R S T M N P R S T
B5, B3/B5 B14
17
B3
B5, B3/B5
B14
Nm
Cs
0
C max
Cn
rpm
230 230 1 1,2 1,2 0,8 0,8 0,8
230 240 1,1 1,2 1,15 0,9 0,9 0,9
230 260 1,2 1,2 1 1 1 1
400 400 1 1,2 1,2 0,8 0,8 0,8
400 440 1,06 1,2 1,1 0,87 0,87 0,87
400 460 1,2 1,2 1 1 1 1
400 480 1,25 1,2 1 1,1 1,1 1,1
Volt 230 380 400 440 690
In 1,74 1,05 1,0 0,91 0,5818
The general electrical specifications are listed in the performance charts that follow. To understand their contents, the following general definitions are provided.
TECHNICAL DATA
Motive motors can face also temporaryoverloads, with Current increases of1.5 times the rated current for at least2 minutes.
Starting current (or locked rotor current):In the performance charts the startingcurrent “Is” is indicated as a multiplevalue of the rated current (Is/In).
Synchronous speed:is expressed in rpm and it is obtainedby the formula
f 120/pf= supply frequency Hzp= number of poles pairs
Rated Power:it is the mechanical power measured atthe shaft expressed, according to thelatest indications of internationalStandards Committees, in Watts orKwatts. However, in the engineeringsector it is still common to refer topower in terms of HP
Rated Voltage:the voltage to be applied to the motorterminals in accordance with thespecifications in the following tables
Frequency:All electrical data in this catalogue referto three-phase wound motors at 50 Hz.These may be connected to 60 Hz,taking into account the multipliercoeff icients in the table below
Rated Current:“In” is the Rated Current, expressed inAmpere, absorbed by the motor whensupplied at rated voltage and giving theRated Power. In the following tables, therated currents are referred to a Voltagesupply of 400V. For other voltage suppliesthe absorbed rated current can beconsidered inversely proportional to thevoltage supply. EX:
Rated torque:Cn is expressed in Nm, and itcorresponds to the rated power andrated rpm. It is given by the It is givenby the multiplication of the force for thearm (distance) and it is measured inNm because the force is expressed inin Newton and the distance in metres.The rated torque value is obtained bythe formula
Cn (Nm) = 9,55 x (Pn/n)Pn= Rated power in KWn= rated rotation speed in rpm
Starting torque (or locked rotor torque):Cs is the torque that the motor canprovide with the rotor at a standstill andthe rated power supply.
Maximum torque:Cmax is the maximum torque developedby the motor at the rated power supply,at a certain speed.It represents also the value of theresistant torque after which the motorstops.In the following performance charts, itis indicated the relation betweenmaximum torque and rated torque andmaximum torque (Cmax/Cn)
Efficiency:η is expressed in % and it is given bythe relation between the output Powerand the addition of output Power andthe electric losses of the motor, that isthe input power absorbed by the motor.The electric motors losses are mainlyof two kinds: for joule effect (rotor andstator) and iron losses.The latest cause essentially heat.An higher efficiency means energysavings, lower heating, longer life ofinsulating materials.
Power factor or cosϕ:it represents the coseno of the voltageand current gap angle.
rated voltageat 50Hz
Volt at60Hz
ratedpower
Wrpm In
IaIn
CaCn
CmaxCn
for further information, see chapter "wiring diagrams" at page 14
19
Noise:The noise is expressed in dB(A). Themeasures must be taken in accordancewith the standard ISO 1680-2, in orderto find the Sound Power level LwAmeasured at 1m of distance from theperimeter of the machine.EN 60034-9 standard describes theacoustic Power limits to be respected,indicating the maximum sound powerlevel LwA. The noise values indicatedin the performance charts that followare referred to a no-load motor working,supplied at 50Hz and with a toleranceof +3 dB(A).
The moment of inertia can be calculatedin this way:J = (1/2) x M x (R2)Where M [Kg] is the rotation mass,while R [m] is the ray of the volume atcylindrical symmetry.
TOLERANCES
Efficiency -15% di (1- n)(Output Power
input Power)
Power factor 1/ 6 of (1- cosϕ) min. 0.02max 0.07
Locked rotor torque -15% of the guaranteed torque+25% of the guaranteed torque
Maximum torque -10% -of the guaranteed torque, if torque is not lessthan 1,5- 1,6 the rated torque
Noise +3dB
Characteristic Tolerance
The data of each motor are specified inthis catalogue like requested by the normIEC 34-1. This describes, in particular, thefollowing tolerances:
20
0,09
0,13
0,18
0,25
0,37
0,55
0,75
1,1
1,5
2,2
3
4
5,5
7,5
9,2
11
15
18,5
22
30
37
45
55
75
90
110
132
160
200
250
315
56A-2
56B-2
63A-2
63B-2
71A-2
71B-2
80A-2
80B-2
90S-2
90L-2
100L-2
112M-2
132SA-2
132SB-2
132MA-2
160MA-2
160MB-2
160L-2
180M-2
200LA-2
200LB-2
225M-2
250M-2
280S-2
280M-2
315S-2
315MA-2
315LA-2
315LB-2
355M-2
355L-2
2800
2800
2800
2800
2800
2800
2825
2825
2840
2840
2880
2890
2900
2900
2930
2930
2930
2930
2940
2950
2950
2970
2970
2970
2970
2980
2980
2980
2980
2985
2985
0,3
0,3
0,5
0,6
0,9
1,3
1,7
2,4
3,2
4,6
5,9
7,7
10,3
14,0
16,9
19,9
26,9
32,4
41,0
55,5
67,9
82,3
100,4
134,4
160,2
195,4
233,2
265,0
330,0
411,0
517,0
5,2
5,2
5,5
5,5
6,1
6,1
6,1
7,0
7,0
7,0
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,1
7,1
7,1
7,1
7,1
7,1
0,31
0,41
0,61
0,96
1,26
1,88
2,54
3,72
0,21
7,40
9,95
13,22
18,11
24,70
25,60
35,85
48,89
60,30
71,46
97,12
119,78
144,70
176,85
241,16
289,39
352,51
423,02
512,75
640,94
799,83
100,79
2,1
2,1
2,2
2,2
2,2
2,2
2,2
2,2
2,2
2,2
2,2
2,2
2,2
2,2
2,2
2,2
2,2
2,2
2,0
2,0
2,0
2,0
2,0
2,0
2,0
1,8
1,8
1,8
1,8
1,8
1,8
0,12
0,18
0,25
0,35
0,5
0,75
1
1,5
2
3
4
5,5
7,5
10
12,5
15
20
25
30
40
50
60
75
100
125
150
180
215
270
340
430
2,2
2,2
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,2
2,2
2,2
2,2
2,2
2,2
62,0
64,0
66,0
69,0
71,0
74,0
76,2
79,3
80,4
81,6
83,5
85,5
86,5
87,1
87,1
88,4
89,4
90,5
90,5
91,4
92,0
92,5
93,0
93,6
94,1
94,4
94,8
95,0
95,0
95,0
95,2
61,0
63,5
64,0
68,5
71,0
73,0
75,7
80,0
80,2
82,7
83,4
85,5
84,5
86,9
86,9
87,4
88,5
90,2
89,9
90,3
91,2
90,9
91,9
93,1
93,1
93,9
94,3
94,5
94,5
94,0
95,2
0,77
0,78
0,80
0,81
0,81
0,82
0,83
0,84
0,84
0,85
0,88
0,88
0,89
0,89
0,89
0,89
0,89
0,91
0,89
0,85
0,89
0,89
0,86
0,90
0,90
0,90
0,88
0,91
0,90
0,90
0,91
0,71
0,73
0,73
0,74
0,75
0,76
0,78
0,82
0,80
0,84
0,85
0,85
0,88
0,89
0,88
0,87
0,88
0,90
0,89
0,83
0,87
0,88
0,84
0,88
0,87
0,87
0,85
0,88
0,88
0,88
0,89
60
60
61
61
64
64
67
67
72
72
76
77
80
80
81
86
86
86
89
92
92
92
93
94
94
96
96
99
99
103
103
3,5
3,6
4,5
4,7
6
6,3
10
11
13
14
25
28
40
45
49
110
120
135
165
217
243
320
390
540
590
880
1000
1055
1110
1900
2300
0,00010
0,00020
0,00031
0,00040
0,00055
0,00060
0,00075
0,00090
0,00120
0,00140
0,00290
0,00550
0,01090
0,01260
0,02000
0,03770
0,04990
0,05500
0,07500
0,12400
0,13900
0,23300
0,31200
0,57900
0,67500
1,18000
1,82000
2,08000
2,38000
3,00000
3,50000
PowerKW
PowerHP Type rpm
CurrentIs/In
TorqueCn (Nm)
TorqueCs/Cn
TorqueCmax/Cn
Efficiency η100% 75%
CurrentIn (A)
Pwr. Fact. cosϕ100% 75%
LwA
(dB)
J
Kgm2Kg
2 Poles asynchronous speed 3000 rpm
21
0,06
0,09
0,13
0,18
0,25
0,25
0,37
0,55
0,55
0,75
1,1
1,1
1,5
2,2
2,2
3
4
5,5
5,5
7,5
9,2
11
15
18,5
22
30
37
45
55
75
90
110
132
160
200
250
315
56A-4
56B-4
63A-4
63B-4
63C-4
71A-4
71B-4
71C-4
80A-4
80B-4
80C-4
90S-4
90L-4
90LB-4
100LA-4
100LB-4
112M-4
112MB-4
132S-4
132MA-4
132MB-4
160M-4
160L-4
180M-4
180L-4
200L-4
225S-4
225M-4
250M-4
280S-4
280M-4
315S-4
315M-4
315LA-4
315LB-4
355M-4
355L-4
1340
1340
1360
1360
1330
1380
1380
1340
1400
1400
1390
1400
1400
1390
1420
1420
1440
1440
1440
1460
1460
1460
1460
1470
1470
1480
1480
1480
1480
1480
1485
1485
1485
1485
1485
1485
1485
0,20
0,30
0,40
0,60
0,73
0,80
1,06
1,44
1,49
1,93
2,67
2,75
3,52
4,86
4,90
6,44
8,36
11,20
11,20
14,80
17,90
21,10
28,60
34,60
41,00
54,70
66,40
80,40
97,80
133,00
158,70
191,00
228,00
273,00
341,00
421,00
528,00
4,0
4,0
4,4
4,4
4,9
5,2
5,2
5,2
5,2
6,0
6,0
6,0
6,0
7,0
7,0
7,0
7,0
7,0
7,0
7,0
7,0
7,0
7,5
7,5
7,5
7,2
7,2
7,2
7,2
7,2
7,2
6,9
6,9
6,9
6,9
6,9
6,9
0,43
0,64
0,84
1,26
1,51
1,73
2,54
3,12
3,78
5,15
7,10
7,50
10,23
13,20
14,80
20,18
26,53
32,30
36,48
49,74
60,05
71,59
98,12
120,19
142,93
160,96
198,51
290,37
354,90
483,95
578,79
707,41
848,89
1028,96
1286,20
1602,35
2018,96
2,0
2,0
2,1
2,1
2,1
2,1
2,1
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,2
2,2
2,2
2,2
2,2
2,2
2,2
2,2
2,1
2,1
2,1
2,1
2,1
2,1
0,09
0,12
0,18
0,25
0,35
0,35
0,5
0,75
0,75
1
1,5
1,5
2
3
3
4
5,5
7,5
7,5
10
12,5
15
20
25
30
40
50
60
75
100
120
150
180
220
270
340
430
2,1
2,1
2,2
2,2
2,2
2,2
2,2
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,2
2,2
2,2
2,2
2,2
2,2
56,0
58,0
59,0
62,0
64,3
68,0
69,3
72,0
72,8
74,4
76,2
76,4
78,5
81,5
82,5
82,6
85,0
85,9
86,7
87,9
87,9
89,2
89,7
90,7
91,6
92,6
92,8
93,4
94,0
94,0
94,0
94,0
94,8
95,0
95,0
95,0
95,0
55,6
58,2
59,0
61,5
64,0
66,5
71,0
71,5
72,6
74,2
76,0
77,8
78,1
81,0
83,0
83,2
84,8
85,1
86,8
88,2
88,2
89,2
89,7
90,6
91,7
92,4
92,7
93,3
94,2
93,5
93,5
93,5
94,8
94,5
94,1
94,4
95,0
0,69
0,7
0,72
0,73
0,74
0,74
0,76
0,75
0,75
0,74
0,77
0,79
0,81
0,79
0,82
0,86
0,83
0,83
0,87
0,87
0,85
0,85
0,85
0,89
0,88
0,87
0,87
0,89
0,89
0,91
0,88
0,88
0,91
0,88
0,89
0,89
0,89
0,61
0,61
0,63
0,65
0,66
0,65
0,65
0,66
0,66
0,65
0,7
0,7
0,75
0,71
0,76
0,78
0,76
0,79
0,81
0,83
0,83
0,83
0,82
0,86
0,85
0,84
0,84
0,87
0,88
0,89
0,86
0,87
0,88
0,85
0,87
0,87
0,86
52
52
52
52
55
55
55
58
58
58
61
61
61
64
64
64
65
71
71
71
72
75
75
76
76
79
81
81
83
86
86
93
93
97
97
101
101
3,5
3,6
4,5
4,7
5,7
6
6,3
7,3
10
11
12,5
13
14
16
23
25
28
35
45
55
59
118
132
164
182
245
258
290
388
510
606
910
1000
1055
1128
1700
1900
0,00015
0,00015
0,00030
0,00040
0,00045
0,00050
0,00080
0,00150
0,00180
0,00210
0,00220
0,00230
0,00270
0,00410
0,00540
0,00670
0,00950
0,01500
0,02140
0,02960
0,03100
0,07470
0,09180
0,13900
0,15800
0,26200
0,40600
0,46900
0,66000
1,12000
1,46000
3,11000
3,62000
4,13000
4,73000
6,50000
8,20000
4 Poles asynchronous speed 1500 rpm
PowerKW
PowerHP Type rpm
CurrentIs/In
TorqueCn (Nm)
TorqueCs/Cn
TorqueCmax/Cn
Efficiency η100% 75%
CurrentIn (A)
Pwr. Fact. cosϕ100% 75%
LwA
(dB)
J
Kgm2Kg
22
0,18
0,25
0,37
0,55
0,75
1,1
1,5
2,2
3
4
5,5
7,5
11
15
18,5
22
30
37
45
55
75
90
110
132
160
200
250
71A-6
71B-6
80A-6
80B-6
90S-6
90L-6
100L-6
112M-6
132S-6
132MA-6
132MB-6
160M-6
160L-6
180L-6
200LA-6
200LB-6
225M-6
250M-6
280S-6
280M-6
315S-6
315MA-6
315LA-6
315LB-6
355MA-6
355MB-6
355L-6
900
900
900
900
910
910
940
940
960
960
960
970
970
970
970
970
980
980
980
980
980
985
985
985
990
990
990
0,70
0,90
1,20
1,70
2,10
3,0
3,70
5,20
6,80
9,0
11,90
16,0
22,50
31,60
38,60
44,70
59,30
71,10
85,90
104,70
141,70
169,50
206,70
244,70
277,00
347,00
432,00
4,0
4,0
4,7
4,7
5,5
5,5
5,5
6,5
6,5
6,5
6,5
6,5
6,5
7,0
7,0
7,0
7,0
7,0
7,0
7,0
7,0
6,7
6,7
6,7
6,7
6,7
6,7
1,91
2,65
3,93
5,84
7,87
11,54
15,24
22,35
29,84
39,79
54,71
73,84
108,30
147,68
182,14
216,60
292,35
360,56
438,52
535,97
730,87
872,59
1066,50
1279,80
1543,43
1292,29
2411,62
1,9
1,9
1,9
1,9
2,0
2,0
2,0
2,1
2,1
2,1
2,1
2,1
2,1
2,1
2,1
2,1
2,0
2,1
2,1
2,1
2,0
2,0
2,0
2,0
1,9
1,9
1,9
0,25
0,35
0,5
0,75
1
1,5
2
3
4
5,5
7,5
10
15
20
25
30
40
50
60
75
100
125
150
180
220
270
340
2,0
2,0
2,0
2,1
2,1
2,1
2,1
2,1
2,1
2,1
2,1
2,1
2,1
2,1
2,1
2,1
2,1
2,1
2,1
2,1
2,0
2,0
2,0
2,0
2,0
2,0
2,0
57,0
60,0
66,5
68,2
74,4
75,2
77,6
79,9
84,5
84,6
85,7
87,0
89,0
89,1
90,0
90,1
91,8
92,8
93,0
93,0
94,0
94,0
94,3
94,7
94,9
94,9
95,0
57,0
59,9
67,7
68,4
73,9
74,7
77,6
79,9
84,6
84,7
86,0
87,0
89,5
89,1
90,2
90,1
91,5
92,8
92,5
92,5
93,5
93,5
93,9
94,2
94,2
94,5
95,0
0,66
0,68
0,70
0,66
0,74
0,75
0,73
0,75
0,77
0,77
0,81
0,76
0,78
0,84
0,82
0,83
0,88
0,86
0,87
0,88
0,88
0,86
0,86
0,87
0,87
0,89
0,88
0,60
0,60
0,62
0,59
0,64
0,66
0,66
0,66
0,71
0,70
0,76
0,71
0,73
0,79
0,78
0,78
0,79
0,86
0,83
0,85
0,85
0,85
0,84
0,84
0,87
0,87
0,86
52
52
54
54
57
57
61
65
69
69
69
73
73
73
76
76
76
78
80
80
85
85
85
85
92
92
92
6
6,3
10
11
13
14
23
25
28
45
55
78
90
160
217
244
295
365
500
545
810
900
1010
1140
1550
1600
1700
0,00110
0,00140
0,00160
0,00190
0,00290
0,00350
0,00690
0,01400
0,02860
0,03570
0,04490
0,00810
0,11600
0,20700
0,31500
0,36000
0,54700
0,84300
1,39000
1,65000
4,11000
4,78000
5,45000
6,12000
9,50000
10,40000
12,40000
6 Poles asynchronous speed 1000 rpm
PowerKW
PowerHP Type rpm
CurrentIs/In
TorqueCn (Nm)
TorqueCs/Cn
TorqueCmax/Cn
Efficiency η100% 75%
CurrentIn (A)
Pwr. Fact. cosϕ100% 75%
LwA
(dB)
J
Kgm2Kg
23
1,5
2,2
3
4
5,5
7,5
11
15
18,5
22
30
37
45
55
75
90
110
112M-8
132S-8
132M-8
160MA-8
160MB-8
160L-8
180L-8
200L-8
225S
225M-8
250M-8
280S-8
280M-8
315S-8
315MA-8
315MB-8
315MC-8
700
710
710
720
720
720
730
730
730
730
730
730
740
740
740
740
740
4,28
5,70
7,53
9,80
12,60
16,90
23,80
32,40
39,00
45,00
60,80
74,00
89,30
105,00
143,00
169,00
206,00
5,0
6,0
6,0
6,0
6,0
6,0
5,5
6,6
6,6
6,6
6,6
6,6
6,6
6,6
6,6
6,6
6,4
20,46
29,59
40,35
53,06
72,59
99,50
143,90
196,23
242,02
287,81
392,47
484,04
580,74
709,80
967,91
1161,49
1419,60
1,8
1,8
1,8
1,9
2,0
2,0
2,0
2,0
1,9
1,9
1,9
1,9
1,8
1,8
1,8
1,8
1,8
2
3
4
5,5
7,5
10
15
20
25
30
40
50
60
75
100
125
150
2,0
2,0
2,0
2,0
2,0
2,0
2,0
2,0
2,0
2,0
2,0
2,0
2,0
2,0
2,0
2,0
2,0
77,2
81,9
83,0
86,0
86,6
87,2
87,8
88,2
91,3
90,0
92,4
92,5
92,6
93,0
93,5
93,7
94,1
77,3
82,2
83,4
85,8
87,3
88,1
87,9
88,7
91,5
90,7
92,3
92,4
92,6
93,0
93,5
93,5
94,5
0,69
0,72
0,74
0,74
0,77
0,79
0,77
0,77
0,76
0,78
0,81
0,78
0,78
0,82
0,82
0,82
0,83
0,60
0,66
0,67
0,64
0,71
0,74
0,70
0,70
0,72
0,75
0,76
0,73
0,73
0,76
0,78
0,78
0,80
61
64
64
68
68
68
70
73
73
73
75
76
76
82
82
82
82
28
45
55
105
78
90
160
235
242
285
390
500
580
790
970
1055
1118
0,02450
0,03140
0,03950
0,07530
0,09310
0,12600
0,20300
0,33900
0,49100
0,54700
0,84300
1,93000
1,65000
4,79000
5,58000
6,37000
7,23000
8 Poles asynchronous speed 750 rpm
PowerKW
PowerHP Type rpm
CurrentIs/In
TorqueCn (Nm)
TorqueCs/Cn
TorqueCmax/Cn
Efficiency η100% 75%
CurrentIn (A)
Pwr. Fact. cosϕ100% 75%
LwA
(dB)
J
Kgm2Kg
��
�
��
�
�
�
��
�
��
�
�
�
�
tipi 180 - 355
24
COMPONENTS LIST
N°
1
2
3
4
5
6
7
8
9
10
11
12
13
CODE
3PNSTA
3PNROT
3PNFRA
3PNFBE
3PNBBE
3PNFOS
3PNBOS
3PNBSH
3PNB03
3PNB05
3PNB14
3PNFEE
3PNWAV
N°
14
15
16
17
18
19
20
21
22
23
24
25
26
CODE
3PNFAN
3PNFCV
3PNUCB
3PNTER
3PNBCB
3PNCMP
3PNCAP
3PNSCB
3PNCCB
3PNFOB
3PNFIB
3PNBIB
3PNBOB
types 180 - 355
�
�
25
RUBBER SEAL RINGS AND BEARINGS
FRAME POLES SIZE NUMBER
56-63 2 - 8 12x25x7 12x25x7 6201 620171 2 - 8 15x30x7 15x30x7 6202 620280 2 - 8 20x35x7 20x35x7 6204 620490 2 - 8 25x40x7 25x40x7 6205 6205100 2 - 8 30x47x7 30x47x7 6206 6206112 2 - 8 30x47x7 30x47x7 6206 6206132 2 - 8 40x62x7 40x62x7 6208 6208160 2 45x62x12 45x62x12 6209 6209160 4 - 8 45x62x12 45x62x12 6309 6309180 2 55x75x12 55x75x12 6211 6211180 4 - 8 55x75x12 55x75x12 6311 6211200 2 60x80x12 60x80x12 6212 6212200 4 - 8 60x80x12 60x80x12 6312 6212225 2 65x90x12 65x90x12 6312 6312225 4 - 8 65x90x12 65x90x12 6313 6312250 2 70x90x12 70x90x12 6313 6313250 4 - 8 70x90x12 70x90x12 6314 6313280 2 80x110x12 80x110x12 6314 6314280 4 - 8 80x110x12 80x110x12 6317 6314315 2 95x120x12 95x120x12 6316 6316315 4 - 8 95x120x12 95x120x12 NU 319 6319355 2 95x120x12 95x120x12 NU 319 6319355 4 8 95x120x12 95x12x12 NU 322 NU 322
� �RUBBER SEAL RING BEARINGS
2 bearings lubricationdevices on the front andthe back shield areprovided in motors fromsize 180 and up.Other motors mountstaunch bearings pre-lubricated for life
26
ALL DATA HAVE BEEN WRITTEN AND CHECKED WITH THE GREATEST CARE.WE DO NOT TAKE ANY RESPONSIBILITY FOR POSSIBLE ERRORS OR OMISSIONS.MOTIVE CAN CHANGE THE CHARACTERISTICS OF THE SOLD ITEMS ON HIS FIRM OPINIONAND IN EVERY MOMENT.
TERMS OF SALE AND GUARANTEE
ARTICLE 4PAYMENT
4.1. Any delayed or irregular paymentsshall entitle Motive to cancel ongoingagreements, including agreements whichdo not regard the payments at issue, aswell as entitling Motive to claim damages,if any. Motive shall, however, have theright, as of the payment’s due date andwithout placing in arrears, to claim interestfor arrears, to the extent of the discountrate in force in Italy, increased by 5 points.Motive shall also have the right to withholdmaterial under repair for replacement.In the case of failed payment, Motive shallhave the right to cancel all guaranteeson materials, as regards the insolventClient.
4.2. The Buyer shall be bound to completepayment, including cases whereby claimsor disputes are underway.
ARTICLE 2CLAIMS
2.1. Without prejudice to the applicationof provisions in Law, dated June 21,1971, and as per Article 1:Claims, regarding quantity, weight, grossweight and colour, or claims regardingfaults and defects in quality or compliance,and which the Buyer may discover ongoods delivery, shall be submitted by amax. 7 days of aforesaid discovery, underpenalty of nullity.
ARTICLE 3DELIVERY
3.1. Any liability for damages ensuingfrom total or partial delayed or faileddelivery, shall be excluded.
3.2. Unless differently communicated bywritten to the Client, the transport termshave to be intended ex-works
The guarantee shall be subject to specificwritten request for Motive to takeaction,according to statements, as describedat the paragraphs hereinbelow.By virtue ofaforesaid approval, and as regards the claim,Motive shall be bound, at its discretion, andwithin a reasonable time-limit, to alternativelytake the following action:
a) To supply the Buyer with products of thesame type and quality as those havingproven defective and not complying withagreements, free ex-works; in aforesaidcase, Motive shall have the right to request,at the Buyer’s charge, early return ofdefective goods, which shall becomeMotive’s property;
b) To repair, at its charge, the defectiveproduct or to modify the product whichdoes not comply with agreements, byperforming aforesaid action at its facilities;in aforesaid cases, all costs regardingproduct transport shall be sustained bythe Buyer.
c) To send spare parts free of charge: allcosts regarding product transport shallbe sustained by the Buyer.
1.3 The guarantee herein shall assimilateand replace legal guarantees for defects anddiscrepancies, and shall exclude any othereventual Motive liability, however caused bysupplied products; in particular, the Buyershall have no right to submit any furtherclaims.Motive shall not be liable for the enforcementof any further claims, as of the date theguarantee ’s term of validity expires.
ARTICLE 1GARANTEE
1.1. Barring written agreements, enteredinto between the parties hereto each time,Motive hereby guarantees compliance ofproducts supplied and compliance withspecific agreements.The guarantee for defects shall be restrictedto product defects following design, materialsor manufacturing defects leading back toMotive.
The Guarantee shall not include:
faults or damages ensuing fromtransport., faults or damages ensuingfrom installation defects; incompetentuse of theproduct, or any otherunsuitable use.
tampering or damages ensuing from useby non-authorised staff and/or use of non-original parts and/or spare parts;
Defects and/or damages ensuing fromchemical agents and/or atmosphericphenomena (e.g. burnt out material, etc.); routine maintenance and required actionor checks;
Products lacking a plate or having a tampered plate.
1.2. Returns to credit or replace will beaccepted only in exceptional cases;However returns of goods already usedto credit or replace won’t be accepted inany case.The guarantee shall be effective for allMotiveproducts, with a term of validity of 12months, starting from the date ofshipment.
motive wishes to thank the following for their help in preparing this catalogue:Studio Grafico Immagine (Brescia)In Immaginabile studio fotografico (Brescia)
Motive s.r.l.
Via G. D’Annunzio, 11 - 25018 MONTICHIARI (BS) - Italy
Tel. +39.030.9962342 - Fax +39.030.962011
web site: www.motive.it - e-mail: [email protected]
GEN
ERAL
CATA
LOG
UE
DEL
PH
ISER
IES
04
09
REV
.0
AREA DISTRIBUTOR
®