Top Banner
Retrofits / Upgrades of Gas Turbine Exhaust Ducts
35

Retrofits / Upgrades of Gas Turbine Exhaust Ducts · Major Drivers of Retrofits / upgrades of Gas Turbine Exhaust Ducts • Change in Power Plant Operation – Due to changes in operating

May 03, 2018

Download

Documents

danghuong
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Retrofits / Upgrades of Gas Turbine Exhaust Ducts · Major Drivers of Retrofits / upgrades of Gas Turbine Exhaust Ducts • Change in Power Plant Operation – Due to changes in operating

Retrofits / Upgrades of

Gas Turbine Exhaust Ducts

Page 2: Retrofits / Upgrades of Gas Turbine Exhaust Ducts · Major Drivers of Retrofits / upgrades of Gas Turbine Exhaust Ducts • Change in Power Plant Operation – Due to changes in operating

Major Drivers ofRetrofits / upgrades of Gas Turbine Exhaust Ducts

• Change in Power Plant Operation

– Due to changes in operating regimes (two shifting etc.) many gas-fired power plants are now facing a significant amount of repetitive maintenance on Gas Turbine Exhaust ducts during their annual outages.

– Damage mechanisms are often related to the increased number of unit starts and high flue gas velocities in the GT exhaust ducting.

– Minor defects in the external / internal insulation of exhaust ducts system can rapidly lead to widespread damage (potential for significant loss of plant availability).

• Upgrading duct systems of ageing Power Plants

– Many of the “older” power stations can be upgraded from a “hot casing” design to a “cold casing” design extending Power Plant Life and reducing maintenance cost.

– “Noise reduction requirements include the installation of additional Silencer splitters

Page 3: Retrofits / Upgrades of Gas Turbine Exhaust Ducts · Major Drivers of Retrofits / upgrades of Gas Turbine Exhaust Ducts • Change in Power Plant Operation – Due to changes in operating

General Capabilities• GE Frame Engine Exhausts

– Frame 3,5,7,9 (Both E,F as H types)

• ALSTOM GT Exhausts– GT8, GT10, GT11, GT13, GT24, GT26

• MITSUBISHI GT Exhausts– 501, 701 (Both D as F Types)

• Siemens GT Exhausts– V64, V94 (Both type 1,2 as well as 3)

• Others– LM engine exhausts, Aeroderivative Exhausts

Page 4: Retrofits / Upgrades of Gas Turbine Exhaust Ducts · Major Drivers of Retrofits / upgrades of Gas Turbine Exhaust Ducts • Change in Power Plant Operation – Due to changes in operating

Typical Damages (1)

Severe cracking and degradation of original duct sections due to thermal shock

Page 5: Retrofits / Upgrades of Gas Turbine Exhaust Ducts · Major Drivers of Retrofits / upgrades of Gas Turbine Exhaust Ducts • Change in Power Plant Operation – Due to changes in operating

Typical Damages (2)

Silencer have detached during operationSevere cracking

Page 6: Retrofits / Upgrades of Gas Turbine Exhaust Ducts · Major Drivers of Retrofits / upgrades of Gas Turbine Exhaust Ducts • Change in Power Plant Operation – Due to changes in operating

Typical Damages (3)

Ducting plates have split Buckling of plate sections

Page 7: Retrofits / Upgrades of Gas Turbine Exhaust Ducts · Major Drivers of Retrofits / upgrades of Gas Turbine Exhaust Ducts • Change in Power Plant Operation – Due to changes in operating

Typical Damages (4)

Further evidence of damage due to thermal shock

Page 8: Retrofits / Upgrades of Gas Turbine Exhaust Ducts · Major Drivers of Retrofits / upgrades of Gas Turbine Exhaust Ducts • Change in Power Plant Operation – Due to changes in operating

Upgrade Programs

• Analysis & Flow Modelling– Supporting Cyclic Power Plant Operation– FEA studies

• to eliminate thermal shock for the silencer supports • overall strength calculations of casing and fluegas silencers

• “cold casing design” option– utilising only internal insulation.– long term internal insulation integrity – safer operating regime – significantly reduced maintenance down time.

Page 9: Retrofits / Upgrades of Gas Turbine Exhaust Ducts · Major Drivers of Retrofits / upgrades of Gas Turbine Exhaust Ducts • Change in Power Plant Operation – Due to changes in operating

Examples of Analysis & Flow Modelling

Flow ModelingStress Calculations

Silencer Support

Stress Calculation Casing

Stress CalculationsFluegas Silencers

Page 10: Retrofits / Upgrades of Gas Turbine Exhaust Ducts · Major Drivers of Retrofits / upgrades of Gas Turbine Exhaust Ducts • Change in Power Plant Operation – Due to changes in operating

Example of upgraded Duct Design

Page 11: Retrofits / Upgrades of Gas Turbine Exhaust Ducts · Major Drivers of Retrofits / upgrades of Gas Turbine Exhaust Ducts • Change in Power Plant Operation – Due to changes in operating

FABRICATION OF DUCTING

• State of the Art fabrication facilities– Larger manufactured and Pre Fabricated

modules – minimizing installation time and Power Plant

Downtime– Reducing Risk by performing shop Trial Fit’s

before installation

• Transport and site logistics– main driver for extent of “Pre Fabrication”

• Site works– Experienced and certified ATA supervisors, HSE

and project managers– Cooperating with experienced local Installation

companies

Page 12: Retrofits / Upgrades of Gas Turbine Exhaust Ducts · Major Drivers of Retrofits / upgrades of Gas Turbine Exhaust Ducts • Change in Power Plant Operation – Due to changes in operating

FABRICATION OF NEW FLUE GAS SILENCERS

• IN-HOUSE engineering– In line with customer specifications– Modular Design adaptable to

specific requirements

• IN HOUSE Manufacturing– Dedicated ATA factory in Nunspeet

Page 13: Retrofits / Upgrades of Gas Turbine Exhaust Ducts · Major Drivers of Retrofits / upgrades of Gas Turbine Exhaust Ducts • Change in Power Plant Operation – Due to changes in operating

REDUCING DOWNTIME / OVERHAUL TIME

- In House Engineering to select best technical & operational options- Advance Project Planning- Site Logistics Planning- Modular design of the replacement ducting - Local Support Companies- Close cooperation with Site and Site Engineers

Completing the project within the critical path of the hot gas path inspection of the gas turbine

Page 14: Retrofits / Upgrades of Gas Turbine Exhaust Ducts · Major Drivers of Retrofits / upgrades of Gas Turbine Exhaust Ducts • Change in Power Plant Operation – Due to changes in operating

Gas Turbine GE Frame 9E Exhaust Duct Replacement Programme

Case Study in Photographs

Report from a Project in the UK

Page 15: Retrofits / Upgrades of Gas Turbine Exhaust Ducts · Major Drivers of Retrofits / upgrades of Gas Turbine Exhaust Ducts • Change in Power Plant Operation – Due to changes in operating

Site preparation to presemble duct pieces (1)

Lay down area prior to commencement of work with core samples being taken to establish ground condition

Page 16: Retrofits / Upgrades of Gas Turbine Exhaust Ducts · Major Drivers of Retrofits / upgrades of Gas Turbine Exhaust Ducts • Change in Power Plant Operation – Due to changes in operating

Site preparation to presemble duct pieces (2)

Concrete footings are poured and a temporary erection stage is assembled

Page 17: Retrofits / Upgrades of Gas Turbine Exhaust Ducts · Major Drivers of Retrofits / upgrades of Gas Turbine Exhaust Ducts • Change in Power Plant Operation – Due to changes in operating

Site preparation to presemble duct pieces (3)

The temporary erection stage is inspected and approved by the station owners

Page 18: Retrofits / Upgrades of Gas Turbine Exhaust Ducts · Major Drivers of Retrofits / upgrades of Gas Turbine Exhaust Ducts • Change in Power Plant Operation – Due to changes in operating

Scaffolding is erected around the stage to allow the pre-fabrication of the modular duct sections

Preparation to receive duct pieces

Page 19: Retrofits / Upgrades of Gas Turbine Exhaust Ducts · Major Drivers of Retrofits / upgrades of Gas Turbine Exhaust Ducts • Change in Power Plant Operation – Due to changes in operating

Arrival of prefabricated duct pieces

Prefabricated / modular replacement duct sections are delivered to site

Page 20: Retrofits / Upgrades of Gas Turbine Exhaust Ducts · Major Drivers of Retrofits / upgrades of Gas Turbine Exhaust Ducts • Change in Power Plant Operation – Due to changes in operating

Lifting prefabricated duct pieces

Modular duct section is lifted onto stage for pre-assembly

Page 21: Retrofits / Upgrades of Gas Turbine Exhaust Ducts · Major Drivers of Retrofits / upgrades of Gas Turbine Exhaust Ducts • Change in Power Plant Operation – Due to changes in operating

Pre assembly of duct parts (1)

Page 22: Retrofits / Upgrades of Gas Turbine Exhaust Ducts · Major Drivers of Retrofits / upgrades of Gas Turbine Exhaust Ducts • Change in Power Plant Operation – Due to changes in operating

Pre assembly of duct parts (2)

Replacement duct sections under assembly

Page 23: Retrofits / Upgrades of Gas Turbine Exhaust Ducts · Major Drivers of Retrofits / upgrades of Gas Turbine Exhaust Ducts • Change in Power Plant Operation – Due to changes in operating

Installation of new flue gas silencers

Dedicated lifting equipment is used to assemble silencer sections

Page 24: Retrofits / Upgrades of Gas Turbine Exhaust Ducts · Major Drivers of Retrofits / upgrades of Gas Turbine Exhaust Ducts • Change in Power Plant Operation – Due to changes in operating

Pre assembly of duct parts (3)

Replacement duct sections under assembly

Page 25: Retrofits / Upgrades of Gas Turbine Exhaust Ducts · Major Drivers of Retrofits / upgrades of Gas Turbine Exhaust Ducts • Change in Power Plant Operation – Due to changes in operating

Completion of pre assembly phase

Completed duct sections prior to installation

Page 26: Retrofits / Upgrades of Gas Turbine Exhaust Ducts · Major Drivers of Retrofits / upgrades of Gas Turbine Exhaust Ducts • Change in Power Plant Operation – Due to changes in operating

Removal of old ducting (1)

Original duct sections are removed by “jacking” and “skidding”

Page 27: Retrofits / Upgrades of Gas Turbine Exhaust Ducts · Major Drivers of Retrofits / upgrades of Gas Turbine Exhaust Ducts • Change in Power Plant Operation – Due to changes in operating

Removal of old ducting (2)

Original duct sections after removal are “jacked” higher to enable transport by dedicated bogie to lay down area

Page 28: Retrofits / Upgrades of Gas Turbine Exhaust Ducts · Major Drivers of Retrofits / upgrades of Gas Turbine Exhaust Ducts • Change in Power Plant Operation – Due to changes in operating

Removal of old ducting (3)

Due to the poor state of the silencers “bracing” is required to facilitate safe removal

Page 29: Retrofits / Upgrades of Gas Turbine Exhaust Ducts · Major Drivers of Retrofits / upgrades of Gas Turbine Exhaust Ducts • Change in Power Plant Operation – Due to changes in operating

Removal of old ducting (4)

Original duct sections are transported to lay down area in preparation for scrap management process

Page 30: Retrofits / Upgrades of Gas Turbine Exhaust Ducts · Major Drivers of Retrofits / upgrades of Gas Turbine Exhaust Ducts • Change in Power Plant Operation – Due to changes in operating

Installation of new duct pieces (1)

Replacement duct sections are transported from lay down area for installation

Page 31: Retrofits / Upgrades of Gas Turbine Exhaust Ducts · Major Drivers of Retrofits / upgrades of Gas Turbine Exhaust Ducts • Change in Power Plant Operation – Due to changes in operating

Installation of new duct pieces (2)

Replacement duct sections are manoeuvred into position in readiness for final tie-in work

Page 32: Retrofits / Upgrades of Gas Turbine Exhaust Ducts · Major Drivers of Retrofits / upgrades of Gas Turbine Exhaust Ducts • Change in Power Plant Operation – Due to changes in operating

Scrapping of old duct sections (1)

Original duct sections are scrapped on the lay down area

Page 33: Retrofits / Upgrades of Gas Turbine Exhaust Ducts · Major Drivers of Retrofits / upgrades of Gas Turbine Exhaust Ducts • Change in Power Plant Operation – Due to changes in operating

Scrapping of old duct sections (2)

The scrap duct sections are cut and removed from site for recycling / processing

Page 34: Retrofits / Upgrades of Gas Turbine Exhaust Ducts · Major Drivers of Retrofits / upgrades of Gas Turbine Exhaust Ducts • Change in Power Plant Operation – Due to changes in operating

Construction (Design and Management) Regulations 2007

Improve health and safety in our industry Have the right people for the right job at the right time to manage the risks

on site Focus on effective planning and managing risk - manage the risk not the

paperwork

Page 35: Retrofits / Upgrades of Gas Turbine Exhaust Ducts · Major Drivers of Retrofits / upgrades of Gas Turbine Exhaust Ducts • Change in Power Plant Operation – Due to changes in operating

Industrieweg 59P.O. Box 658070 AB NunspeetThe NetherlandsTel: +31 – (0)341 – 252635Fax: +31 – (0)341 – 262112Web: http://www.ata-bv.com