Problem 1

1. A shell-and-tube exchanger (2 shells, 4 tube passes) is used to heat 10,000 kg/h of pressurized water from 35 to 120OC with 5000 kg/h pressurized water entering the exchanger at 300OC. If the overall heat transfer coefficient is 1500 W/m2-K, determine the required heat exchanger area.

GIVEN: Water Working fluid (hot and cold)

U= 1500 W/m2-K

Figure 1. Shell-and-tube Heat Exchanger (2 shells – 4 tube passes) REQUIRED: Area

Page 3: Resolved QUIZ

Problem 1

SOLUTION:Reference: Fundamentals of Heat and Mass Transfer, 6th Ed. IncroperaProperties: Table A.6, Water

Page 4: Resolved QUIZ

Problem 1

Page 5: Resolved QUIZ

Problem 1

Page 6: Resolved QUIZ

Problem 1

Page 7: Resolved QUIZ

Problem 2

2. Consider the heat exchanger in problem 1. After several years of operation it is observed that the outlet temperature of the cold water reaches only 95OC rather than the desired 120OC for the same flow rates and inlet temperatures of the fluids. Determine the cumulative (inner and outer) fouling factor that is the cause of the poorer performance.

GIVEN: Water Working fluid (hot and cold)

A (from Problem 1) = 4.75 m2

Rt” = 1500 W/m2-

Figure 2. Shell-and-tube Heat Exchanger (2 shells – 4 tube passes)

REQUIRED: U, Rf ”

Page 8: Resolved QUIZ

Problem 2

SOLUTION:Reference: Fundamentals of Heat and Mass Transfer, 6th Ed. IncroperaProperties: Table A.6, Water

Page 9: Resolved QUIZ

Problem 2

Page 10: Resolved QUIZ

Problem 2

Page 11: Resolved QUIZ

Problem 2

Page 12: Resolved QUIZ

Problem 3

3. In a dairy operation, milk at a flow rate of 250 liter/hour and a cow body temperature of 38.6°C must be chilled to a safe to store temperature of 13°C or less. Ground water at 10°C is available at a flow rate of 0.72 m3/h. The density and specific heat of water are 1030 kg/m3 and 3860 J/kg·K.

(a) Determine the UA product of a counterflow heat exchanger required for the chilling process. Determine the

length of the exchanger if the inner pipe has a 50-mm diameter and the overall heat transfer coefficient is U = 1000

W/m2 ·K.(b) Determine the outlet temperature of the water.(c) using the UA from part a, determine the milk outlet temperature if

the water flow rate is doubled  

Page 13: Resolved QUIZ

Problem 3

GIVEN: 

Figure 3. Counterflow heat exchangerREQUIRED:1. UA and Length, L2. Tc,o @ UA3. Tc,o if:

2 Vwater

Vwater/2

Page 14: Resolved QUIZ

SOLUTION: Reference: Fundamentals of Heat and Mass Transfer, 6th Ed. IncroperaProperties:  

Page 15: Resolved QUIZ
Page 16: Resolved QUIZ