Residential/Light Commercial Generator Accessories Kohlerr OnCuer Generator Management System Software * Model RXT ATS and LCM can be used with generator sets equipped with the RDC2 or DC2 controller. [ PIM can be used with generator sets equipped with the VSC, RDC2, or DC2 controller. OnCuer User Interface -- Gauges View OnCuer User Interface -- Power Chain View for RDC2 OnCuer User Interface -- Power Chain View for VSC G6-116 (OnCuer) 1/13e Applicable Models D VSC Controller d 6VSG variable-speed DC generator set D RDC2 or DC2 Controller d 14/20RESA generator sets d 14/20RESAL generator sets d 38RCL generator set d 48RCL generator set D RDC or DC Controller d 14/20RES generator sets d 14/20RESL generator sets OnCuer Features D Power Chain View monitors your Kohlerr generator set, RXT automatic transfer switch*, Load Control Module (LCM)*, and Programmable Interface Module (PIM)[ from any location in the world with Internet access. D Control home automation when generator set is paired with a Programmable Interface Module (PIM)[. Remotely turn on or off appliances, outdoor lighting, storm shutters, etc. D RDC2/DC2 and VSC controllers have built-in Ethernet capability. D Receive generator set start/stop and fault messages by email or SMS text message. Kohlerr OnCuer server sends email and text messages anytime, without requiring your computer to be turned on. D Install OnCuer software on one or more personal computers. D Monitor multiple generator sets. Navigation panel displays status information for multiple generator systems and allows easy selection of one generator set for detailed monitoring and control. D Start exercises from your computer. D Stop the generator set exercise and clear faults from your computer. D View time- and date-stamped event history listing generator set starting and stopping, faults, and notifications. D Simple connection and setup -- just enter generator set serial number, controller password, and activation code (if required). No router setup is required. D Controller password and generator set serial number protect against access by unauthorized users. D All Ethernet communication is fully authenticated and encrypted for privacy.
6
Embed
Residential/Light Commercial Generator Accessories · 2013-01-23 · Residential/Light Commercial Generator Accessories Kohler OnCue Generator Management System Software * Model RXT
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
OnCue� User Interface -- Power Chain View for RDC2
OnCue� User Interface -- Power Chain View for VSC
G6-116 (OnCue�) 1/13e
Applicable Models� VSC Controller
� 6VSG variable-speed DC generator set
� RDC2 or DC2 Controller
� 14/20RESA generator sets
� 14/20RESAL generator sets
� 38RCL generator set
� 48RCL generator set
� RDC or DC Controller
� 14/20RES generator sets
� 14/20RESL generator sets
OnCue� Features� Power Chain View monitors your Kohler� generator set, RXT
automatic transfer switch*, Load Control Module (LCM)*, andProgrammable Interface Module (PIM)� from any location inthe world with Internet access.
� Control home automation when generator set is paired with aProgrammable Interface Module (PIM)�. Remotely turn on oroff appliances, outdoor lighting, storm shutters, etc.
� RDC2/DC2 and VSC controllers have built-in Ethernetcapability.
� Receive generator set start/stop and fault messages by emailor SMS text message. Kohler� OnCue� server sends emailand text messages anytime, without requiring your computerto be turned on.
� Install OnCue� software on one or more personal computers.
� Monitor multiple generator sets. Navigation panel displaysstatus information for multiple generator systems and allowseasy selection of one generator set for detailed monitoringand control.
� Start exercises from your computer.
� Stop the generator set exercise and clear faults from yourcomputer.
� View time- and date-stamped event history listing generatorset starting and stopping, faults, and notifications.
� Simple connection and setup -- just enter generator set serialnumber, controller password, and activation code (ifrequired). No router setup is required.
� Controller password and generator set serial number protectagainst access by unauthorized users.
� All Ethernet communication is fully authenticated andencrypted for privacy.
G6-116 (OnCue�) 1/13e
View System Operation Data
Generator Set with RDC, DC, RDC2,or DC2Controllers
� Generator set running or stopped
� Generator output frequency, Hz
� Generator output voltage, VAC
� Engine speed, RPM
� Engine starting battery voltage, VDC
� Engine run time, hours
� Fault indication with description
� Generator operation event history
� Status information for multiple generator sets displayed in thenavigation panel
Generator Set with VSC Controller
� Generator set running or stopped
� % load
� Generator output DC voltage, VDC
� Engine speed, RPM
� Engine starting battery voltage, VDC
� Engine run time, hours
� Fault indication with description
� Generator operation event history
� Status information for multiple generator sets displayed in thenavigation panel
ATS (RXT only)*� Source availability
� ATS position
Load Control Module (LCM)*� View current loads and shed loads
� Dual color LEDs for each load indicate load status (poweredor shed) and flash to indicate a test
� Change load labels to identify which loads are powered andshed
� See G6-120 for more information
Programmable Interface Module (PIM)�� View relay status
� Green/gray LEDs to indicate on/off
� Change input and output labels
� See G6-121 for more information
6VSG Communications Kit� View input and output status
� Green/gray LEDs to indicate on/off
Remote Control/Home Automation
Generator Set� Start/Stop exercises remotely
� Clear or reset faults remotely
Programmable Interface Module (PIM)�� Turn relays on and off remotely to control appliances, outdoor
lighting, storm shutters, etc.
* Model RXT ATS and LCM can be used with generator sets equipped with the RDC2 or DC2 controller.
� PIM can be used with generator sets equipped with the VSC, RDC2, or DC2 controller.
G6-116 (OnCue�) 1/13e
Typical Connections
VSC Generator SetController
* Customer-provided
� One PIM or one communications kit may be installed
Ethernet cables *
Kohler� System
PIM �
BatteryBank *
VSC Controller
Router *Cable or DSL
Modem *
LocalPC *
UPS *(optional)
RemotePC *
Multiple PCs canbe connected.
OnCue� Serveron the Internet
RDC2 or DC2Generator Set Controller Router *
Cable or DSLModem *
* Customer-provided
LocalPC *
Ethernet cables *
UPS *(optional)
RemotePC *
Kohler� System
Multiple PCs canbe connected.
ATS LCM PIM
RDC2/DC2 Controller
OnCue� Serveron the Internet
RDC or DCController
EthernetBoard
* Customer-provided
Ethernet cables *
Kohler� Generator Set
RDC/DC Controller
Router *Cable or DSL
Modem *
LocalPC *
UPS *(optional)
RemotePC *
Multiple PCs canbe connected.
OnCue� Serveron the Internet
G6-116 (OnCue�) 1/13e
OnCue� System
KOHLER� Model38RCL or 48RCL
Generator
Cell PhoneSMS Text Message
Local PC
Remote PCCustomer
Office/Vacation/Travel
G6-116
KOHLER� Model14/20RESA/RESAL or
14/20RES/RESL
KOHLER� Model 6VSGGenerator
Remote PCDealer /Service
OnCue Server onthe Internet
Power Chain View, RDC2/DC2 Controller
G6-116 (OnCue�) 1/13e
Power Chain View, VSC Controller
Power Chain View, VSC Controller with Communications Kit
KOHLER CO., Kohler, Wisconsin 53044 USAPhone 920-457-4441, Fax 920-459-1646For the nearest sales and service outlet in theUS and Canada, phone 1-800-544-2444KOHLERPower.com
Availability is subject to change without notice. Kohler Co. reserves theright to change the design or specifications without notice and without anyobligation or liability whatsoever. Contact your local Kohler� generatordistributor for availability.