Residential Softeners Revised: 07/2016 Residential Softeners Section 2 Page 1 Kinetico ® Series Models 2020c HE 2020c HF AquaKinetic ® Q237 2040s OD Certifications NSF 44 NSF 44 NSF 61 NSF 44 WQA 44 Class DIR DIR DIR DIR Efficiency 3350 Yes Yes Flow Rate 6.0 gpm 9.1 gpm 9.0 11 gpm Max. Hardness 30 gpg 20 gpg 37 gpg 44 gpg Inlet Size ¾” - 1” ¾” - 1” ¾” - 1” ¾” - 1½” Tank Size 6” x 13” 6” x 13” 8” x 18” 8” x 17” Distributor Size 1” 1” 1” 1” Resin Quantity 0.16 cf x 2 0.16 cf x 2 0.30 cf x 2 0.4 cf x 2 Underbed No No No No Capacities gr / lbs. / gpp gr / lbs. / gpp gr / lbs. / gpp gr / lbs. / gpp Minimum 2177 / .5 / 4355 1400 / .5 / 2800 4015 / 1 / 4015 Maximum 2775 / .75 / 3700 1870 / .75 / 2493 4366 / 1.25 / 3493 5222 / 1.0 / 5222 Valve Type 1.0” 3 cycle NE 1.0” 3 cycle NE 1.0” 3 cycle NE 1.25” 3 cycle NE Cycle Initiation Meter Meter Meter Meter Regen Water / Time 5 gal. / 11 min. 5 gal. / 11 min. 19 gal. / 29 min. 7 gal. / 11 min. Max Drain Flow 0.9 gpm 0.9 gpm 2.2 gpm 1.6 gpm Electrical None None None None
36
Embed
Residential Softeners - yourkinetico.com · Residential Softeners ... Packed bed units are primarily designed for achieving high efficiency hardness removal. ... Engineered Plastic
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Residential Softeners
Revised: 07/2016 Residential Softeners Section 2
Page 1
Kinetico® Series Models
2020c HE
2020c HF
AquaKinetic® Q237
2040s OD
Certifications NSF 44 NSF 44 NSF 61 NSF 44
WQA 44
Class DIR DIR DIR DIR
Efficiency 3350 Yes Yes
Flow Rate 6.0 gpm 9.1 gpm 9.0 11 gpm
Max. Hardness 30 gpg 20 gpg 37 gpg 44 gpg
Inlet Size ¾” - 1” ¾” - 1” ¾” - 1” ¾” - 1½”
Tank Size 6” x 13” 6” x 13” 8” x 18” 8” x 17”
Distributor Size 1” 1” 1” 1”
Resin Quantity 0.16 cf x 2 0.16 cf x 2 0.30 cf x 2 0.4 cf x 2
Underbed No No No No
Capacities gr / lbs. / gpp gr / lbs. / gpp gr / lbs. / gpp gr / lbs. / gpp
Valve Type 1.25” 3 cycle NE 1.25” 3 cycle NE 1.25” 3 cycle NE
Cycle Initiation Meter Meter Meter
Regen Water / Time 102 gal. / 90 min. 102 gal. / 90 min. 142 gal. / 90 min.
Max Drain Flow 3.2 gpm 3.2 gpm 5.2 gpm
Electrical None None None
Abbreviations: gr Grains of hardness removed per cycle.
lbs Pounds of NaCl used per cycle. Gpp Grains of hardness removed per pound of salt per cycle.
Notes: All models countercurrent regeneration. Additional salt settings available. Warranty: 10 years. Resin 10 years if carbon combination system or preceded by
dechlorinator, otherwise 7 years.
Kinetico 2020c HF
Section 2 Residential Softeners Revised: 07/2016
Page-4
8”
System Components Media Vessel (qty) Size ......................................................... (2) 6 x 13” Media Vessel Construction ...................................... Engineered Plastic Empty Bed Volume .................................................................... 0.16 ft3 Media Type ................................................. Uniform Bead Cation Resin Media Volume ............................................................................ 0.16 ft3 Bed Depth ................................................................................. Packed Free Board .................................................................................... None Riser Tube ................................................................................. 1” ABS Distributor Upper .................0.009” Slots, Engineered Plastic Basket Lower .................. 0.009” Slots, Stainless Steel Flat Plate Under bedding .............................................................................. None Regeneration Control ........................................ Non-electric Use Meter Regeneration Type ......................................................... Countercurrent Meter Type ................................0.3 - 25.00 gpm Polypropylene Turbine
Inlet Water Quality Pressure Range ................................... 15 – 125 psi Dynamic Pressure Temperature Range ........................................................... 35 – 120o F pH Range ...............................................................................5 – 10 SU Free Chlorine Cl2 (Max.) .......................................................... 2.0 mg/L Hardness as CaCO3 (Max.) ........................................................ 20 gpg
Operating Specs Flow Range (15 / 30 psig) ............................................ 9.10 – 14.9 gpm Flow Configuration ............................................................... Alternating Dimensions (width x depth x height) .................................... 8 x 18 x 19” Weight (Operating / Shipping) .............................................. 85 / 45 lbs.
Connections Inlet / Outlet Connections ......................... Custom Adapter and Bracket Drain Connection ............................................................... 0.065” Tube Brine Line Connection .......................................... .0.25” Tube (internal) Overflow Connection .......................................................... 0.625” Tube Power ........................................................................................... None
System Part Numbers Kinetico 2020c HF ..................................................................... 10706B
Brine Tank Options Tank Description ........................................................................................................................... ...................... ....................... 2020c Cabinet Brine Tank Part Number ................................................................................................................ ...................... ....................... ........... 10704A Tank Height................................................................................................................................... ...................... ....................... .................. 19” Tank Footprint ............................................................................................................................... ...................... ....................... ............ 8 x 18” Material ......................................................................................................................................... ...................... ....................... ................ ABS Salt Capacity ................................................................................................................................. ...................... ....................... ............ 20 lbs.
Regeneration Specifications Regeneration Volume ............................................................. 5 gallons Regeneration Time ............................................................... 11 minutes Backwash Flow Control ...........................................................0.70 gpm Brine Refill Flow Control ..........................................................0.30 gpm
Disc Selection (Compensated Hardness*) Setting Capacity Efficiency Dosing Meter Disc 1 2 3 4 5 6 7 8 **0.5 lbs. 1,400 grains 2,800 gr./lb. 2.8 lbs./ft3 2 4 5 7 9 11 13 15 **0.75 lbs. 1,870 grains 2,493 gr./lb. 4.2 lbs./ft3 2 5 7 10 13 15 18 20 Gallons/Regeneration: 583 292 194 146 117 97 83 73 **settings certified by NSF and or WQA *Compensated hardness in gpg = Hardness + (3 x Fe in mg/L)
1.75”
19”
18”
Kinetico® 2020c HF
Revised: 07/2016 Residential Softeners Section 2
Page 5
Service Notes – Kinetico 2020c HF
▶ Meter = 6 gallons per tooth.
▶ Drain port in ⅜” NPT.
▶ This is an upflow unit.
▶ Packed bed units are primarily designed for achieving high efficiency hardness removal.
▶ Maximum ferrous iron is 1.0 ppm. These units should not be used where ferric iron is present.
▶ Must be prefiltered.
▶ Do not attempt to remove distributor tubes. They are snap fit and cannot be removed.
▶ Uses Kinetico 1000 Level One.
▶ Use MED-420 lubricant, part number 11319 on blue quad rings and O-rings.
▶ Do not use Dow 111 silicone on blue seals.
▶ Level 1 center to center is 1¾”.
▶ .5 lb. setting is float pushed all the way down.
▶ .75 lb. setting is 4 ½” from bottom of the valve to the top of the float cup.
Kinetico® 2020c HE
Section 2 Residential Softeners Revised: 07/2016
Page-6
8”
System Components Media Vessel (qty) Size ......................................................... (2) 6 x 13” Media Vessel Construction ...................................... Engineered Plastic Empty Bed Volume .................................................................... 0.16 ft3 Media Type ...................................................... Fine Mesh Cation Resin Media Volume ............................................................................ 0.16 ft3 Bed Depth ................................................................................. Packed Free Board .................................................................................... None Riser Tube ................................................................................. 1” ABS Distributor Upper .................0.009” Slots, Engineered Plastic Basket Lower .................. 0.009” Slots, Stainless Steel Flat Plate Under bedding .............................................................................. None Regeneration Control ........................................ Non-electric Use Meter Regeneration Type ......................................................... Countercurrent Meter Type ................................0.3 - 25.00 gpm Polypropylene Turbine
Inlet Water Quality Pressure Range ................................... 15 – 125 psi Dynamic Pressure Temperature Range ........................................................... 35 – 120o F pH Range ...............................................................................5 – 10 SU Free Chlorine Cl2 (Max.) .......................................................... 2.0 mg/L Hardness as CaCO3 (Max.) ........................................................ 30 gpg
Operating Specs Flow Range (15 / 30 psig) .............................................. 6.0 – 10.1 gpm Flow Configuration ............................................................... Alternating Dimensions (width x depth x height) .................................... 8 x 18 x 19” Weight (Operating / Shipping) .............................................. 85 / 45 lbs.
Connections Inlet / Outlet Connections ......................... Custom Adapter and Bracket Drain Connection ............................................................... 0.625” Tube Brine Line Connection .......................................... .0.25” Tube (internal) Overflow Connection .......................................................... 0.625” Tube Power ........................................................................................... None
System Part Numbers Kinetico 2020c HE..................................................................... 10705B
Brine Tank Options Tank Description ........................................................................................................................... ...................... ....................... 2020c Cabinet Brine Tank Part Number ................................................................................................................ ...................... ....................... ........... 10704A Tank Height................................................................................................................................... ...................... ....................... .................. 19” Tank Footprint ............................................................................................................................... ...................... ....................... ............ 8 x 18” Material ......................................................................................................................................... ...................... ....................... ................ ABS Salt Capacity ................................................................................................................................. ...................... ....................... ............ 20 lbs.
Regeneration Specifications Regeneration Volume ............................................................. 5 gallons Regeneration Time ............................................................... 11 minutes Backwash Flow Control ...........................................................0.70 gpm Brine Refill Flow Control ..........................................................0.30 gpm
Disc Selection (Compensated Hardness*) Setting Capacity Efficiency Dosing Meter Disc 1 2 3 4 5 6 7 8 **0.5 lbs. 2,177 grains 4,385 gr./lb. 2.8 lbs./ft3 3 6 9 12 15 18 20 23 **0.75 lbs. 2,755 grains 3,700 gr./lb. 4.2 lbs./ft3 4 7 11 15 19 23 26 30 Gallons/Regeneration: 583 292 194 146 117 97 83 73 **settings certified by NSF and or WQA *Compensated hardness in gpg = Hardness + (3 x Fe in mg/L)
1.75”
19”
18”
Kinetico® 2020c HE
Revised: 07/2016 Residential Softeners Section 2
Page 7
Service Notes – Kinetico 2020c HE
▶ Meter = 6 gallons per tooth.
▶ Drain port in ⅜” NPT.
▶ This is an upflow unit.
▶ Packed bed units are primarily designed for achieving high efficiency hardness removal.
▶ Maximum ferrous iron is 1.0 ppm. These units should not be used where ferric iron is present.
▶ Must be prefiltered.
▶ Do not attempt to remove distributor tubes. They are snap fit and cannot be removed.
▶ Uses Kinetico 1000 Level One.
▶ Use MED-420 lubricant, part number 11319 on blue quad rings and O-rings.
▶ Do not use Dow 111 silicone on blue seals.
▶ Level 1 center to center is 1¾”.
▶ .5 lb. setting is float pushed all the way down.
▶ .75 lb. setting is 4 ½” from bottom of the valve to the top of the float cup.
AquaKinetic® Q237
Section 2 Residential Softeners Revised: 07/2016
Page-8
24”
System Components Media Vessel (qty) Size ........................................................ (2) 8” x 18” Media Vessel Construction .......Fiberglass Wrapped Engineered Plastic Empty Bed Volume .................................................................... 0.40 ft3 Media Type ................................................... Non Solvent Cation Resin Media Volume ............................................................................ 0.30 ft3 Bed Depth ........................................................................................ 12” Free Board ......................................................................................... 5” Riser Tube ................................................................................. 1” ABS Distributor Upper .................0.014” Slots, Engineered Plastic Basket Lower .................0.014” Slots, Engineered Plastic Basket Under-bedding .............................................................................. None Regeneration Control ........................................ Non-electric Use Meter Regeneration Type ......................................................... Countercurrent Meter Type ............................. .0.30 - 25.00 gpm Polypropylene Turbine
Inlet Water Quality Pressure Range ................................... 15 – 125 psi Dynamic Pressure Temperature Range ............................................................ 35 – 120o F pH Range ...............................................................................5 – 10 SU Free Chlorine Cl2 (Max.) ...........................................................2.0 mg/L Hardness as CaCO3 (Max.) ........................................................ 37 gpg
Operating Specs Flow Range (15 / 30 psig) .................................................... 8 – 12 gpm Flow Configuration ............................................................... Alternating Dimensions (width x depth x height) ................................. 17” x 8” x 24” Weight (Operating / Shipping) ............................................ 120 / 80 lbs.
Connections Inlet / Outlet Connections ......................... Custom Adapter and Bracket Drain Connection ................................................................... 0.5” Tube Brine Line Connection ....................................................... .0.375” Tube Power ........................................................................................... None
System Part Numbers Q237, 18” x 35” brine drum ......................................................... 13385 Q237, 12” x 16” x 20” brine drum................................................. 13386 Q237, no brine drum ................................................................... 13387
Brine Tank Options Tank Description ........................................................................................................................... ........... 12 x 40 .... 12 x 16 x 20 ........... 18 x 35 Brine Tank Part Number ................................................................................................................ ............ 1479B ............... 7202 ............... 7938 Tank Height................................................................................................................................... ................. 40” .................. 20” .................. 35” Tank Footprint ............................................................................................................................... .......... 12” DIA .......... 12 x 16” ........... 18” DIA Material ......................................................................................................................................... ............. HDPE ............. HDPE ............. HDPE Salt Capacity ................................................................................................................................. .......... 100 lbs. ............. 50 lbs. .......... 250 lbs.
Regeneration Specifications Regeneration Volume ........................................................... 19 gallons Regeneration Time ............................................................... 29 minutes Backwash Flow Control ...........................................................2.00 gpm Brine Refill Flow Control ..........................................................0.40 gpm
▶ This unit uses gray control disc part number 7931.
▶ Removable distributor tubes – part number 13392.
▶ Can be used with 18 x 35, 12 x 20, or 12 x 40 brine drum.
▶ Meter = 8 gallons per tooth.
▶ Drain port is ⅜” NPT.
▶ This unit can use ¾” or 1” in/out adapters.
▶ This is a downflow service unit.
▶ Uses Kinetico 1000 Level 1.
▶ May be plumbed in ¾ - 1”.
▶ Level 1 center to center is 1¾”.
Kinetico® 2040s OD
Section 2 Residential Softeners Revised: 07/2016
Page-10
17”
2.5”
System Components Media Vessel (qty) Size ......................................................... (2) 8 x 17” Media Vessel Construction ...................................... Engineered Plastic Empty Bed Volume .................................................................... 0.40 ft3 Media Type ...................................................... Fine Mesh Cation Resin Media Volume ............................................................................ 0.40 ft3 Bed Depth ................................................................................. Packed Free Board .................................................................................... None Riser Tube ................................................................................. 1” ABS Distributor Upper .................0.009” Slots, Engineered Plastic Basket Lower .................. 0.009” Slots, Stainless Steel Flat Plate Under bedding .............................................................................. None Regeneration Control ........................................ Non-electric Use Meter Regeneration Type ......................................................... Countercurrent Meter Type ................................0.3 - 25.00 gpm Polypropylene Turbine
Inlet Water Quality Pressure Range ................................... 15 – 125 psi Dynamic Pressure Temperature Range ........................................................... 35 – 120o F pH Range ...............................................................................5 – 10 SU Free Chlorine Cl2 (Max.) .......................................................... 2.0 mg/L Hardness as CaCO3 (Max.) ........................................................ 44 gpg
Operating Specs Flow Range (15 / 30 psig) ............................................. 11.0 - 15.0 gpm Flow Configuration ................................................................ OverDrive Dimensions (width x depth x height) .................................... 17 x 8 x 23” Weight (Operating / Shipping) ............................................ 120 / 90 lbs.
Connections Inlet / Outlet Connections ......................... Custom Adapter and Bracket Drain Connection ................................................................... 0.5” Tube Brine Line Connection ....................................................... .0.375” Tube Power ........................................................................................... None
System Part Numbers Kinetico 2040s OD, 12 x 16 x 20 brine tank ................................. 11120 Kinetico 2040s OD, no brine tank ................................................ 11121 Kinetico 2040s OD, no resin, no brine tank ................................. 12526
Brine Tank Options Tank Description .............................................................................................................. K-Spray ........... 12 x 40 .... 12 x 16 x 20 ........... 18 x 35 Brine Tank Part Number ..................................................................................................... 9763A ............ 1479B ............... 7202 ............... 7938 Tank Height.............................................................................................................................. 35” ................. 40” .................. 20” .................. 35” Tank Footprint ................................................................................................................... 18” DIA .......... 12” DIA .......... 12 x 16” ........... 18” DIA Material ............................................................................................................................... HDPE ............. HDPE ............. HDPE ............. HDPE Salt Capacity .................................................................................................................... 200 lbs. .......... 100 lbs. ............. 50 lbs. ........... 250 lbs
Regeneration Specifications Regeneration Volume ............................................................. 7 gallons Regeneration Time ............................................................... 11 minutes Backwash Flow Control ...........................................................1.40 gpm Brine Refill Flow Control ..........................................................0.40 gpm
▶ Packed bed units are primarily designed for achieving high efficiencies in hardness removal applications.
▶ Maximum ferrous iron 1.0 ppm. These units should not be used when ferric iron is present.
▶ Must be prefiltered.
▶ Do not attempt to remove distributor tubes. They are snap fit and cannot be removed.
▶ Uses Kinetico 1250 Level One.
▶ Use MED-420 lubricant, part number 11319 on blue quad rings and O-rings. Do not use Dow 111 silicone on blue seals.
▶ Can be plumbed in ¾”, 1”, 1¼”, or 1½” plumbing.
▶ Level 1 center to center is 2½”.
Kinetico® 2040c
Section 2 Residential Softeners Revised: 07/2016
Page-12
2.5”
27.13”
System Components Media Vessel (qty) Size ......................................................... (2) 8 x 17” Media Vessel Construction .......Fiberglass Wrapped Engineered Plastic Empty Bed Volume .................................................................... 0.40 ft3 Media Type ...................................................... Fine Mesh Cation Resin Media Volume ............................................................................ 0.40 ft3 Bed Depth ................................................................................. Packed Free Board .................................................................................... None Riser Tube ................................................................................. 1” ABS Distributor Upper .................0.009” Slots, Engineered Plastic Basket Lower .................. 0.009” Slots, Stainless Steel Flat Plate Under bedding .............................................................................. None Regeneration Control ........................................ Non-electric Use Meter Regeneration Type ......................................................... Countercurrent Meter Type ................................0.3 - 25.00 gpm Polypropylene Turbine
Inlet Water Quality Pressure Range ................................... 15 – 125 psi Dynamic Pressure Temperature Range ............................................................ 35 – 120o F pH Range ...............................................................................5 – 10 SU Free Chlorine Cl2 (Max.) ...........................................................2.0 mg/L Hardness as CaCO3 (Max.) ........................................................ 44 gpg
Operating Specs Flow Range (15 / 30 psig) ............................................. 11.0 - 15.0 gpm Flow Configuration ................................................................ OverDrive Dimensions (width x depth x height) ................. 11.42” x 11.42” x 27.19” Weight (Operating / Shipping) ............................................ 100 / 81 lbs.
Connections Inlet / Outlet Connections ............................ Custom Adapter and E-clip Drain Connection ................................................................... 0.5” Tube Brine Line Connection ....................................................... .0.375” Tube Power ........................................................................................... None
System Part Numbers Kinetico 2040c ............................................................................ 12502
Regeneration Specifications Regeneration Volume ............................................................. 7 gallons Regeneration Time ............................................................... 11 minutes Backwash Flow Control ...........................................................1.40 gpm Brine Refill Flow Control ..........................................................0.40 gpm
▶ Packed bed units are primarily designed for achieving high efficiencies in hardness removal applications.
▶ Maximum ferrous iron 1.0 ppm. These units should not be used when ferric iron is present.
▶ Must be prefiltered.
▶ Do not attempt to remove distributor tubes. They are snap fit and cannot be removed.
▶ Uses Kinetico 1250 Level 1.
▶ Use MED-420 lubricant, part number 11319 on blue quad rings and O-rings. Do not use Dow 111 silicone on blue seals.
▶ Can be plumbed in ¾”, 1”, 1¼”, or 1½” plumbing.
▶ Level 1 center to center is 2½”.
▶ Optional salt divider for use with block salt. Part number 12491.
Kinetico® 2030s
Section 2 Residential Softeners Revised: 07/2016
Page-14
System Components Media Vessel (qty) Size ......................................................... (2) 7 x 35” Media Vessel Construction ................................ Wrapped Polyethylene Empty Bed Volume .................................................................... 0.70 ft3 Media Type ................................................... Non Solvent Cation Resin Media Volume ............................................................................ 0.47 ft3 Bed Depth ........................................................................................ 22” Free Board ....................................................................................... 13” Riser Tube ................................................................................. 1” ABS Distributor Upper ....................................... 0.014” Slots, ABS Basket Lower ....................................... 0.014” Slots, ABS Basket Under bedding .............................................................................. None Regeneration Control ........................................ Non-electric Use Meter Regeneration Type ......................................................... Countercurrent Meter Type ............................. .0.30 - 25.00 gpm Polypropylene Turbine
Inlet Water Quality Pressure Range ................................... 15 – 125 psi Dynamic Pressure Temperature Range ........................................................... 35 – 120o F pH Range ...............................................................................5 – 10 SU Free Chlorine Cl2 (Max.) .......................................................... 2.0 mg/L Hardness as CaCO3 (Max.) ........................................................ 45 gpg
Operating Specs Flow Range (15 / 30 psig) .................................................... 9 – 15 gpm Flow Configuration ............................................................... Alternating Dimensions (width x depth x height) .................................... 15 x 7 x 41” Weight (Operating / Shipping) .......................................... 140 / 105 lbs.
Connections Inlet / Outlet Connections ......................... Custom Adapter and Bracket Drain Connection ................................................................... 0.5” Tube Brine Line Connection ....................................................... .0.375” Tube Power ........................................................................................... None
System Part Numbers Kinetico 2030s, 18 x 35 brine drum ........................................... 11020A Kinetico 2030s, 12 X 40 brine drum ........................................... 11084A Kinetico 2030s, K-Spray ............................................................ 11081A Kinetico 2030s, no brine drum ................................................... 11021A Kinetico 2030s, no brine drum, no resin .................................... 11083A
Brine Tank Options Tank Description ........................................................................................................................... ........... 12 x 40 .......... K-Spray ........... 18 x 35 Brine Tank Part Number ................................................................................................................ ............ 1479B ............. 1479B ............... 7938 Tank Height................................................................................................................................... ................. 40” .................. 35” .................. 35” Tank Footprint ............................................................................................................................... .......... 12” DIA ........... 18” DIA ........... 18” DIA Material ......................................................................................................................................... ............. HDPE ............. HDPE ............. HDPE Salt Capacity ................................................................................................................................. .......... 100 lbs. ........... 200 lbs. .......... 250 lbs.
Regeneration Specifications Regeneration Volume ........................................................... 29 gallons Regeneration Time ............................................................... 40 minutes Backwash Flow Control ...........................................................1.40 gpm Brine Refill Flow Control ..........................................................0.40 gpm
▶ Can be plumbed in ¾”, 1”, 1 ¼”, or 1 ½” plumbing.
▶ Uses Kinetico 1250 Level 1 with half louver nozzle.
▶ Meter = 13 gallons per tooth.
▶ Drain port is ⅜” NPT x ½” tube.
▶ This is a downflow service unit.
▶ Uses 18 x 35 standard drum, 12 x 40, or K Spray brine drums.
▶ Meets California efficiency requirements at the 1.8 lb. salt setting.
▶ Level 1 center to center is 2 ½”.
Kinetico® 2060s
Section 2 Residential Softeners Revised: 07/2016
Page-16
46”
2.5”
System Components Media Vessel (Qty.) Size ...................................................... (2) 8” x 40” Media Vessel Construction ................................ Wrapped Polyethylene Empty Bed Volume .................................................................... 1.04 ft3 Media Type ................................................... Non Solvent Cation Resin Media Volume ............................................................................ 0.70 ft3 Bed Depth ........................................................................................ 27” Free Board ....................................................................................... 13” Riser Tube ................................................................................. 1” ABS Distributor Upper ....................................... 0.014” Slots, ABS Basket Lower ....................................... 0.014” Slots, ABS Basket Under bedding .............................................................................. None Regeneration Control ........................................ Non-electric Use Meter Regeneration Type ......................................................... Countercurrent Meter Type ............................. .0.30 - 25.00 gpm Polypropylene Turbine
Inlet Water Quality Pressure Range ................................... 15 – 125 psi Dynamic Pressure Temperature Range ........................................................... 35 – 120o F pH Range ...............................................................................5 – 10 SU Free Chlorine Cl2 (Max.) .......................................................... 2.0 mg/L Hardness as CaCO3 (Max.) ........................................................ 66 gpg
Operating Specs Flow Range (15 / 30 psig) ............................................ 11.5 – 18.0 gpm Flow Configuration ............................................................... Alternating Dimensions (Width x Depth x Height) ............................... 17” x 8” x 46” Weight (Operating / Shipping) .......................................... 200 / 140 lbs.
Connections Inlet / Outlet Connections ............................ Custom Adapter and E-clip Drain Connection ................................................................... 0.5” Tube Brine Line Connection ....................................................... .0.375” Tube Power ........................................................................................... None
System Part Numbers Kinetico 2060s, 18” x 35” brine drum ........................................... 11006 Kinetico 2060s, no brine drum ..................................................... 11007 Kinetico 2060s, no resin, no brine drum ...................................... 11199
Brine Tank Options Tank Description ........................................................................................................................... ........... 12 x 40 .......... K-Spray ........... 18 x 35 Brine Tank Part Number ................................................................................................................ ............ 1479B ............. 9763A ............... 7938 Tank Height................................................................................................................................... ................. 40” .................. 35” .................. 35” Tank Footprint ............................................................................................................................... .......... 12” DIA ........... 18” DIA ........... 18” DIA Material ......................................................................................................................................... ............. HDPE ............. HDPE ............. HDPE Salt Capacity ................................................................................................................................. .......... 100 lbs. ........... 200 lbs. .......... 250 lbs.
Regeneration Specifications Regeneration Volume ........................................................... 35 gallons Regeneration Time ............................................................... 45 minutes Backwash Flow Control ...........................................................2.00 gpm Brine Refill Flow Control ..........................................................0.40 gpm
▶ This unit meets California efficiency requirements at the 2.7 lb. salt setting.
▶ Can be plumbed in ¾”, 1”, 1¼”, 1½” plumbing.
▶ Uses Kinetico 1250 Level One with ½ louver nozzle.
▶ Level 1 center to center is 2½”.
Kinetico® 2060s OD
Section 2 Residential Softeners Revised: 07/2016
Page-18
46”
2.5”
System Components Media Vessel (qty) Size ......................................................... (2) 8 x 40” Media Vessel Construction ................................ Wrapped Polyethylene Empty Bed Volume .................................................................... 1.04 ft3 Media Type ................................................... Non Solvent Cation Resin Media Volume ............................................................................ 0.70 ft3 Bed Depth ........................................................................................ 25” Free Board ....................................................................................... 15” Riser Tube ................................................................................. 1” ABS Distributor Upper ....................................... 0.014” Slots, ABS Basket Lower ....................................... 0.014” Slots, ABS Basket Under bedding .............................................................................. None Regeneration Control ........................................ Non-electric Use Meter Regeneration Type ......................................................... Countercurrent Meter Type ............................. .0.75 - 40.00 gpm Polypropylene Turbine
Inlet Water Quality Pressure Range ................................... 15 – 125 psi Dynamic Pressure Temperature Range ........................................................... 35 – 120o F pH Range ...............................................................................5 – 10 SU Free Chlorine Cl2 (Max.) .......................................................... 2.0 mg/L Hardness as CaCO3 (Max.) ........................................................ 30 gpg
Operating Specs Flow Range (15 / 30 psig) ............................................ 20.5 – 30.0 gpm Flow Configuration ................................................................. Overdrive Dimensions (width x depth x height) .................................... 17 x 8 x 46” Weight (Operating / Shipping) .......................................... 200 / 140 lbs.
Connections Inlet / Outlet Connections ............................ Custom Adapter and E-clip Drain Connection ................................................................... 0.5” Tube Brine Line Connection ....................................................... .0.375” Tube Power ........................................................................................... None
System Part Numbers Kinetico 2060s OD, 18 x 35 brine drum ....................................... 11201 Kinetico 2060s OD, no brine drum ............................................... 11202 Kinetico 2060s OD, no resin, no brine drum ................................ 11789
Brine Tank Options Tank Description ........................................................................................................................... ...................... .......... K-Spray ........... 18 x 35 Brine Tank Part Number ................................................................................................................ ...................... ............. 1479B ............... 7938 Tank Height................................................................................................................................... ...................... .................. 35” .................. 35” Tank Footprint ............................................................................................................................... ...................... ........... 18” DIA ........... 18” DIA Material ......................................................................................................................................... ...................... ............. HDPE ............. HDPE Salt Capacity ................................................................................................................................. ...................... ........... 200 lbs. .......... 250 lbs.
Regeneration Specifications Regeneration Volume ........................................................... 35 gallons Regeneration Time ............................................................... 45 minutes Backwash Flow Control ...........................................................2.00 gpm Brine Refill Flow Control ..........................................................0.40 gpm
▶ Uses Kinetico 1250 Level One with full louver nozzle.
▶ Drain port is ⅜” NPT x ½” tube.
▶ This is a downflow service unit.
▶ Can be used with 18 x 35, 12 x 40, or K-Spray brine drum.
▶ Meets California efficiency requirements at the 2.7 lb. salt setting.
▶ Level 1 center to center is 2½”.
Kinetico® 2100s
Section 2 Residential Softeners Revised: 07/2016
Page-20
60”
2.5”
System Components Media Vessel (qty) Size ....................................................... (2) 10 x 54” Media Vessel Construction ................................ Wrapped Polyethylene Empty Bed Volume .................................................................... 2.19 ft3 Media Type ................................................... Non Solvent Cation Resin Media Volume .............................................................................. 1.5 ft3 Bed Depth ........................................................................................ 36” Free Board ....................................................................................... 18” Riser Tube ................................................................................. 1” ABS Distributor Upper ....................................... 0.014” Slots, ABS Basket Lower ....................................... 0.014” Slots, ABS Basket Under bedding .............................................................................. None Regeneration Control ........................................ Non-electric Use Meter Regeneration Type ......................................................... Countercurrent Meter Type ............................. .0.30 - 25.00 gpm Polypropylene Turbine
Inlet Water Quality Pressure Range ................................... 15 – 125 psi Dynamic Pressure Temperature Range ........................................................... 35 – 120o F pH Range ...............................................................................5 – 10 SU Free Chlorine Cl2 (Max.) .......................................................... 2.0 mg/L Hardness as CaCO3 (Max.) ...................................................... 107 gpg
Operating Specs Flow Range (15 / 30 psig) ............................................ 12.0 – 19.0 gpm Flow Configuration ............................................................... Alternating Dimensions (width x depth x height) .................................. 21 x 10 x 60” Weight (Operating / Shipping) .......................................... 350 / 175 lbs.
Connections Inlet / Outlet Connections ............................ Custom Adapter and E-clip Drain Connection ................................................................... 0.5” Tube Brine Line Connection ....................................................... .0.375” Tube Power ........................................................................................... None
System Part Numbers Kinetico 2100s, 18 x 35 brine drum ............................................. 11031 Kinetico 2100s, no brine drum ..................................................... 11050 Kinetico 2100s, no resin .............................................................. 11051 Kinetico 2100s, no brine drum, no resin ...................................... 11052
Brine Tank Options Tank Description ........................................................................................................................... ...................... ........... 12 x 40 ........... 18 x 35 Brine Tank Part Number ................................................................................................................ ...................... ............. 1479B ............... 7938 Tank Height................................................................................................................................... ...................... .................. 40” .................. 35” Tank Footprint ............................................................................................................................... ...................... ........... 12” DIA ........... 18” DIA Material ......................................................................................................................................... ...................... ............. HDPE ............. HDPE Salt Capacity ................................................................................................................................. ...................... ........... 100 lbs. .......... 250 lbs.
Regeneration Specifications Regeneration Volume ......................................................... 102 gallons Regeneration Time ............................................................... 90 minutes Backwash Flow Control ...........................................................3.00 gpm Brine Refill Flow Control ..........................................................0.70 gpm
▶ Can be plumbed with ¾”, 1”, 1¼” or 1½” plumbing.
▶ Uses Kinetico 1250 Level 1 with half louver nozzle.
▶ Drain port is ⅜” NPT x ½” tube.
▶ This is a downflow service unit.
▶ Uses 18 x 35 brine tank.
▶ Meets California efficiency requirements at the 5.5 and 10.0 lb. salt settings.
▶ Level 1 center to center is 2½”.
Kinetico® 2100s OD
Section 2 Residential Softeners Revised: 07/2016
Page-22
60”
2.5”
System Components Media Vessel (qty) Size ....................................................... (2) 10 x 54” Media Vessel Construction ................................. Wrapped Polyethylene Empty Bed Volume .................................................................... 2.19 ft3 Media Type ................................................... Non Solvent Cation Resin Media Volume .............................................................................. 1.5 ft3 Bed Depth ........................................................................................ 36” Free Board ....................................................................................... 18” Riser Tube ................................................................................. 1” ABS Distributor Upper ....................................... 0.014” Slots, ABS Basket Lower ....................................... 0.014” Slots, ABS Basket Under bedding .............................................................................. None Regeneration Control ........................................ Non-electric Use Meter Regeneration Type ......................................................... Countercurrent Meter Type ............................. .0.75 - 40.00 gpm Polypropylene Turbine
Inlet Water Quality Pressure Range ................................... 15 – 125 psi Dynamic Pressure Temperature Range ............................................................ 35 – 120o F pH Range ...............................................................................5 – 10 SU Free Chlorine Cl2 (Max.) ...........................................................2.0 mg/L Hardness as CaCO3 (Max.) ........................................................ 57 gpg
Operating Specs Flow Range (15 / 30 psig) ............................................ 21.0 – 31.0 gpm Flow Configuration ................................................................. Overdrive Dimensions (width x depth x height) .................................. 21 x 10 x 60” Weight (Operating / Shipping) .......................................... 350 / 175 lbs.
Connections Inlet / Outlet Connections ............................ Custom Adapter and E-clip Drain Connection ................................................................... 0.5” Tube Brine Line Connection ....................................................... .0.375” Tube Power ........................................................................................... None
System Part Numbers Kinetico 2100s OD, 18 x 35 brine drum ....................................... 11128 Kinetico 2100s OD, no brine drum ............................................... 11129 Kinetico 2100s OD, no resin, no brine drum ................................ 11777
Brine Tank Options Tank Description ........................................................................................................................... ...................... ........... 12 x 40 ........... 18 x 35 Brine Tank Part Number ................................................................................................................ ...................... ............. 1479B ............... 7938 Tank Height................................................................................................................................... ...................... .................. 40” .................. 35” Tank Footprint ............................................................................................................................... ...................... ........... 12” DIA ........... 18” DIA Material ......................................................................................................................................... ...................... ............. HDPE ............. HDPE Salt Capacity ................................................................................................................................. ...................... ........... 100 lbs. .......... 250 lbs.
Regeneration Specifications Regeneration Volume ......................................................... 102 gallons Regeneration Time ............................................................... 90 minutes Backwash Flow Control ...........................................................3.00 gpm Brine Refill Flow Control ..........................................................0.70 gpm
** Settings certified by NSF and or WQA *Compensated hardness in gpg = Hardness + (3 x Fe in mg/L)
10”
21”
Kinetico® 2100s OD
Revised: 07/2016 Residential Softeners Section 2
Page 23
Service Notes
▶ Can be plumbed in ¾”, 1” 1¼”, or 1½” plumbing.
▶ Uses Kinetico 1250 Level 1 with full louver.
▶ Meter = 40 gallons per tooth.
▶ Drain Port is ⅜” NPT x ½” tube.
▶ This is a downflow service unit.
▶ Uses 18” x 35” brine drum.
▶ Meets California efficiency requirements at the 5.5 and 10.0 lb. salt settings.
▶ Level 1 center to center is 2½”.
Kinetico® 2175s
Section 2 Residential Softeners Revised: 07/2016
Page-24
60”
2.5”
System Components Media Vessel (qty) Size ....................................................... (2) 13 x 54” Media Vessel Construction ................................ Wrapped Polyethylene Empty Bed Volume .................................................................... 3.68 ft3 Media Type ................................................... Non Solvent Cation Resin Media Volume ............................................................................ 2.25 ft3 Bed Depth ........................................................................................ 37” Free Board ....................................................................................... 17” Riser Tube ................................................................................. 1” ABS Distributor Upper ....................................... 0.014” Slots, ABS Basket Lower ....................................... 0.014” Slots, ABS Basket Under bedding ..................................................... 0.25 ft3 ¼ x ⅛ Gravel Regeneration Control ........................................ Non-electric Use Meter Regeneration Type ......................................................... Countercurrent Meter Type ............................. .0.30 - 25.00 gpm Polypropylene Turbine
Inlet Water Quality Pressure Range ................................... 25 – 125 psi Dynamic Pressure Temperature Range ........................................................... 35 – 120o F pH Range ...............................................................................5 – 10 SU Free Chlorine Cl2 (Max.) .......................................................... 2.0 mg/L Hardness as CaCO3 (Max.) ...................................................... 175 gpg
Operating Specs Flow Range (15 / 30 psig) ............................................ 16.0 – 22.0 gpm Flow Configuration ............................................................... Alternating Dimensions (width x depth x height) .................................. 27 x 13 x 60” Weight (Operating / Shipping) .......................................... 450 / 300 lbs.
Connections Inlet / Outlet Connections ............................ Custom Adapter and E-clip Drain Connection ............................................................... 0.625” Tube Brine Line Connection ....................................................... .0.375” Tube Power ........................................................................................... None
System Part Numbers Kinetico 2175s, 24 x 40 brine drum ............................................. 11036 Kinetico 2175s, no brine drum ..................................................... 11054 Kinetico 2175s, resin on the side, no brine drum ......................... 11056 Kinetico 2175s, no resin, no brine drum ...................................... 11832
Brine Tank Options Tank Description ........................................................................................................................... ...................... ....................... ........... 24 x 40 Brine Tank Part Number ................................................................................................................ ...................... ....................... ............. 10586 Tank Height................................................................................................................................... ...................... ....................... .................. 40” Tank Footprint ............................................................................................................................... ...................... ....................... ........... 24” DIA Material ......................................................................................................................................... ...................... ....................... ............. HDPE Salt Capacity ................................................................................................................................. ...................... ....................... .......... 500 lbs.
Regeneration Specifications Regeneration Volume ......................................................... 142 gallons Regeneration Time ............................................................... 90 minutes Backwash Flow Control ...........................................................5.00 gpm Brine Refill Flow Control ..........................................................0.70 gpm
Disc Selection (Compensated Hardness*) Setting Capacity Efficiency Dosing Meter Disc 1 2 3 4 5 6 7 8 **15 lbs. 65,139 grains 4,342 gr./lb. 6.7 lbs./ft3 27 50 70 88 103 117 129 140 **30 lbs. 81,845 grains 2,728 gr./lb. 13.3 lbs./ft3 34 62 87 110 129 146 162 175 Gallons/Regeneration: 1,715 858 572 429 343 286 245 214 ** Settings certified by NSF and or WQA *Compensated hardness in gpg = Hardness + (3 x Fe in mg/L)
13”
27”
Kinetico® 2175s
Revised: 07/2016 Residential Softeners Section 2
Page 25
Service Notes
▶ May be plumbed in ¾”, 1”, 1¼” or 1½” plumbing.
▶ Uses Kinetico 1250 Level 1 with ½ louver nozzle.
▶ Drain elbow is ½” NPT x 5/8” tube.
▶ Meter = 17.5 gallons per tooth.
▶ Gravel underbed – 24 lbs. per tank.
▶ DO NOT LAY UNIT ON SIDE.
▶ This is a downflow service unit.
▶ Standard brine tank is 24” x 40”.
▶ An 18” x 35” brine drum can be used for a 15 lbs. salt setting only.
▶ Meets California efficiency requirements at the 15.0 lb. salt setting.
▶ Level 1 center to center is 2½”.
Brine Drum Settings
Section 2 Residential Softeners Revised: 07/2016
Page-26
In Kinetico Softeners, the Brine Drum mixes and stores a solution of salt or potassium chloride for regeneration of the softener media. During the Brine Rinse cycle, this solution is drawn from the brine drum and through the media to regenerate it. The Brine Drum contains an adjustment to draw the correct amount of salt or potassium chloride solution for each cycle. This adjustment is made in two places: the Adjuster Tube and the Float Cup. The Adjuster Tube measures the amount of solution that is drawn from the brine drum into the softener during the Brine Rinse cycle. The Float Cup height determines how much softened water flows back into the brine drum to prepare for the next regeneration. Adjuster Tube Setting
The Adjuster Tube is set by cutting and removing tabs on both sides of the tube. Using a pocket-knife, cut across each tab horizontally, following the channel in the plastic, and break off each tab individually until the proper setting is reached. The remaining number or letter imprinted on the tab determines the correct setting. The drawing at right shows an Adjuster Tube at setting "M". Float Cup Setting
The Float Cup is set by adjusting its height above the bottom of the Brine Valve Assembly. By removing the Brine Valve Assembly and resting it on a flat surface, the height of the Float Cup can be measured with a ruler. The height is measured from the base of the Brine Valve Assembly to the top of the Float Cup (see drawing at right). Note that standard settings are defined by markings on the rod of the Brine Valve Assembly. The settings on the rod are listed in the tables at the end of this section. Where the predefined settings are not adequate, the actual Float Cup height, in inches, is listed, and the setting must be measured and set according to the measured Float Cup height. Installing the Brine Valve
After the adjustments have been made to the Adjuster Tube and the Float Cup, the Brine Valve Assembly must be installed in the Brine Drum. Locate the brine valve in the brine well so that
Adjuster Tube (setting= 1.5)
Float Cup Height Adjustment
Float Cup Height
Side View
Brine Well
Top View
Brine Valve Installation
Brine Drum Settings
Revised: 07/2016 Residential Softeners Section 2
Page 27
the ⅜" bent tube is along the back of the brine well away from the brine drum wall. The ⅜" bent tube snaps into a notch and extends from the brine drum about 1". Application
Note: Do not drop the brine valve into the drum! Dropping may lower the Float Cup, resulting
in an improper setting. Determining the correct Brine Valve settings for a particular application is a three-step process:
1. Determine compensated hardness. This requires a hardness test and an iron test on raw water at the application site. Compensated hardness is calculated by multiplying the ferrous iron (in ppm) by 3 and adding it to the grains of hardness.
2. Determine salt setting. The salt setting is determined by taking the compensated hardness (calculated in step 1 above) and using the Specifications Table, located in each specification section, for the proper model of softener to look up a suitable meter disc and salt setting.
3. Determine Adjuster Tube and Float Cup height settings. Use the Brine Drum specifications on the following pages and the model of a Brine Drum to determine the correct settings for both the Adjuster Tube and the Float Cup height.
Note: This process does not apply to the 2080f Greensand Filters. These filters are shipped preset from the factory and do not require setting.
KEY (Salt Setting – pounds of salt)
1.0 = 1.0 E = 3.0 M = 6.0
1.25 = 1.25 F = 3.3 N = 7.5
1.5 = 1.5 G = 3.6 O = 8.5
A = 1.8 H = 4.0 P = 10.0
B = 2.1 J = 4.4 Q = 12.5
C = 2.4 K = 5.0 R = 15.0
D = 2.7 L = 5.5
18 x 35 Brine Drum
Section 2 Residential Softeners Revised: 07/2016
Page-28
Standard Settings
1 7¾”
2 8⅝”
3 9½”
4 11⅜”
5 13⅜”
Salt - with Grid
Salt Setting 1.0 1.25 1.5 A B C D E F G H J K L M N O P Q R
Adjuster Tube 1.0 1.25 1.5 A B C D E F G H J K L M N N N N N
* Kinetico strongly recommends removing the grid plate when using potassium chloride. KCl - without Grid Salt Setting 1.0 1.25 1.5 A B C D E F G H J K L M N O P Q R
Adjuster Tube K M M N N N N N N N N N M N N N N N N N
* Compensated hardness is determined by multiplying the number of ppm of ferrous iron x 3 and adding to the actual hardness.
Recommendations are based on target concentration of 20% @ 68ºF.
K-Spray
Section 2 Residential Softeners Revised: 07/2016
Page-34
Float Dimensions
Kinetico 2040s OD
Kinetico 4040s OD Kinetico 2030s
Kinetico 2060s
Kinetico 2060s OD
Kinetico 4060s OD
Carbon
A ¼” ¼” ¼” ¼”
B 17” 17⅝” 17” 17”
C ¼” ¼” ¼” ¼”
A
B
C
2020c HE & HF
Revised: 07/2016 Residential Softeners Section 2
Page 35
There are two salt settings that can be used on both of these systems. The ¾ lb. setting allows you to increase
gallons between regenerations without replacing the meter disc. The float cup is raised 4 ½” measured from the bottom of the valve to the top of the float cup as shown in Figure 1 below. The ½ lb. setting will allow for the
most salt efficiency. The float cup is pushed all the way down as shown in Figure 2 below. These systems may either use block sale or pellet salt.
H:\Kinetico\Library\DRAWINGS\CONSUMER\CPD Literature Illus\692+738 Tech Manual\Basic Systems\CC2020c - Brine Valve Illustration.dft