Page 1: Reporting Radiographer Sonographer A well established function with high rate of satisfaction.

Reporting RadiographerSonographer

A well established function with high rate of satisfaction

Page 2: Reporting Radiographer Sonographer A well established function with high rate of satisfaction.

Questions

• Do patients have the same expectations

• In relation to – Quality of the examination– Quality of diagnosis– Information– Further treatment

Page 3: Reporting Radiographer Sonographer A well established function with high rate of satisfaction.

FINDINGS

Patient 251 - 985

Retrospectiv Analysis.

Page 4: Reporting Radiographer Sonographer A well established function with high rate of satisfaction.

Statistic

• 735 Reports.

• Nothing abnormal = 204 patients / 27,7%.

• 964 findings in 531 patients = ratio at 1,8

• Help to examination = 130 examinations / 17,6%

Page 5: Reporting Radiographer Sonographer A well established function with high rate of satisfaction.

Patological findings.

• Gall bladder with

– Stone 196 patients = 26,7%– Sludge +– PLGB Polyp lesion in Gall bladder = 43

patients

– 239 patients / 32,5%

Page 6: Reporting Radiographer Sonographer A well established function with high rate of satisfaction.

Patological findings.

• Focal lesions 28 patients. = 3,8%– Liver metastasis– Pancreatic tumor– Hypernephroma

• Cysts 85pt. = 11,6%– Kidneys– Liver

Page 7: Reporting Radiographer Sonographer A well established function with high rate of satisfaction.

Patological findings.

• Liver steatose 83

• Haemangiomas 15

• Pancreatic 32

• Spleen 47

Page 8: Reporting Radiographer Sonographer A well established function with high rate of satisfaction.

Patological findings.

• Nephrolithiasis 32

• Hydronephrosis 35

• Aorta – ectasia / sclerosis 30

• Ascites 35

Page 9: Reporting Radiographer Sonographer A well established function with high rate of satisfaction.

Patological findings.

• Other: 173 patients = 23,5%• Calcifications, Angiomyolipomas• Lipioma / fibroma, Stents• Nephropathia, Cirrhosis, Dilatatio via bilarum• Cholecystitis, Portal enlarged lymph nodes,• Situs inversus, Nephrocalcinosis.• A. renalis stenosis.

Page 10: Reporting Radiographer Sonographer A well established function with high rate of satisfaction.

Patological findings.

• GB:

• 520, 589, 629, 635, 782,

Page 11: Reporting Radiographer Sonographer A well established function with high rate of satisfaction.

Patological findings.

• Focal Lesions: – Lever metastasis: 567, 645, 659, 872 – Pancreatic tumor: 600, – Hypernephroma:

• Cysts: 520, 541, 792, 818,

Page 12: Reporting Radiographer Sonographer A well established function with high rate of satisfaction.
Page 13: Reporting Radiographer Sonographer A well established function with high rate of satisfaction.

Materials and Methods

• A retrospective analysis of reports• Inconclusions criteria• Patients with classical upper abdominal

problems such as GB-stones or ulcer symptoms

• Selections bias are minimised by exclusion of patients with known oncological diseases or complicated procedures

Page 14: Reporting Radiographer Sonographer A well established function with high rate of satisfaction.

Method

• A retrospective reading on reports of patients referred to fasting Ultrasound examination of the upper abdomen.

• This gives a clear picture of the prevalence in own material. Both regarding own examinations, but also with the possibility to compare with the radiologists within the speciality.

Page 15: Reporting Radiographer Sonographer A well established function with high rate of satisfaction.

Data gathering• Included:• 250 Patients with:

– classical symptoms of gall bladder stones– Non characteristic symptoms of upper abdomen– Para clinical weight loss– Abnormal hepatic blood counts

• Excluded:Patients in known oncological treatment

Complicated examinations done by radiologists

Selection bias are hereby tried to be minimised.

Page 16: Reporting Radiographer Sonographer A well established function with high rate of satisfaction.

ResultsXX Hospital50

YY Hospital50

ZZ Hospital50

ReRa x2100

Total

250

Other diagnosis 18 27 19 48 112

Polyps 3 4 1 2 10

Gall bladder stones

12 5 10 16 43

Nothing abnormal 23 19 24 42 108

Page 17: Reporting Radiographer Sonographer A well established function with high rate of satisfaction.

Results %

XX Hospital50

YY Hospital50

ZZ Hospital50

ReRa x2100

Total

250

Other Diagnosis 36% 54% 38% 48% 45%

Polyps 6% 8% 2% 2% 4%

Gall bladder stones 24% 10% 20% 16% 17%

Nothing abnormal 46% 38% 48% 42% 43%

Page 18: Reporting Radiographer Sonographer A well established function with high rate of satisfaction.
Page 19: Reporting Radiographer Sonographer A well established function with high rate of satisfaction.

Production and economi

• Data gathering from the past 10 weeks

• 36% of the examinations were carried out by Reporting Radiographer

• 11 patients per day – 56 % non planned included

Page 20: Reporting Radiographer Sonographer A well established function with high rate of satisfaction.

Positive and negative impact

• Positive– Shorter waiting time – all time is waiting time– A none negliable better prognose in treatment

of other patient with cancer diseases– Less worries in 27,7% - case closed without

findings!– Cheaper salary– More free ”space” for more complicated

procedures for the radiologists

Page 21: Reporting Radiographer Sonographer A well established function with high rate of satisfaction.

Positive and negative impact

• Negative– None! – (no complains in more than 8.000

examinations!)– but– ”2” patient had asked for a ”doctor”

Page 22: Reporting Radiographer Sonographer A well established function with high rate of satisfaction.

Future aspects

• Educationel matters

• DSDU the Danish Society of Diagnostic Ultrasound ”Drivers license”

• Training programmes

• EFSUMB recommendations

• Developing new fields– Well described borders

Page 23: Reporting Radiographer Sonographer A well established function with high rate of satisfaction.

Conclusion

• Educationally conditions

• Well described frames an borders

• High success ratio with an

• Positive impact on

• Patient satisfaction and treatment and

• Economy

• Therefore

Page 24: Reporting Radiographer Sonographer A well established function with high rate of satisfaction.

Reporting Radiographer

are needed!

Thank you for your attention