January 2012
TRANSFIELD SERVICES PTY. LTD.
EastLink Ventilation Stack Emission Monitoring Report October -
December 2011
This document is issued in accordance with NATA's accreditation
requirements. Accredited for compliance with ISO/IEC 17025. The
results of the tests, calibrations and/or measurements included in
this document are traceable to Australian/national standards.
REPO
RT
Report Number. 097613024-020-R-Rev0 Distribution:1 Hard Copy:
Transfield Services Pty. Ltd. 1 Hard Copy: Golder Associates Pty.
Ltd. Electronic Copy: Transfield Services Pty. Ltd.
Submitted to:Transfield Services Pty. Ltd., EastLink Operations
Centre, 2 Hillcrest Avenue, Ringwood, 3134
-
EASTLINK VENTILATION STACK EMISSION MONITORING REPORT: OCTOBER -
DECEMBER 2011
January 2012 Report No. 097613024-020-R-Rev0
Record of Issue
Company Client Contact Version Date Issued Method of
Delivery
Transfield Services Pty. Ltd., EastLink Operations Centre, 2
Hillcrest Avenue, Ringwood, 3134
Ms. Alex Monson Revision 0 31/01/2012 Electronic/Post
-
EASTLINK VENTILATION STACK EMISSION MONITORING REPORT: OCTOBER -
DECEMBER 2011
January 2012 Report No. 097613024-020-R-Rev0 i
Table of Contents
1.0 INTRODUCTION
........................................................................................................................................................
1
2.0 DISCHARGES TO AIR
..............................................................................................................................................
2
3.0 VENTILATION STACK MONITORING PARAMETERS
............................................................................................
3
4.0 METHODS
.................................................................................................................................................................
4
4.1 PM2.5
.............................................................................................................................................................
4
4.2
PM10..............................................................................................................................................................
4
4.3 Carbon Monoxide
.........................................................................................................................................
4
4.4 Oxides of Nitrogen
........................................................................................................................................
5
4.5 Stack Velocity
...............................................................................................................................................
5
5.0 MEASUREMENT UNCERTAINTY
............................................................................................................................
6
6.0 VENTILATION STACK EMISSION MONITORING PERIOD:
01/10/2011 – 31/10/2011 ...........................................
7
6.1 Data Capture
................................................................................................................................................
7
6.2 Results
..........................................................................................................................................................
8
6.2.1 PM2.5
.......................................................................................................................................................
8
6.2.2 PM10
........................................................................................................................................................
9
6.2.3 Carbon Monoxide
..................................................................................................................................
10
6.2.4 Oxides of Nitrogen
................................................................................................................................
11
6.2.4.1 Nitric Oxide
........................................................................................................................................
11
6.2.4.2 Nitrogen Dioxide
................................................................................................................................
12
6.2.5 Stack Velocity
.......................................................................................................................................
13
6.3 Data Validation and Exceptions
..................................................................................................................
14
7.0 VENTILATION STACK EMISSION MONITORING PERIOD:
01/11/2011 – 30/11/2011 .........................................
16
7.1 Data Capture
..............................................................................................................................................
16
7.2 Results
........................................................................................................................................................
17
7.2.1 PM2.5
.....................................................................................................................................................
17
7.2.2 PM10
......................................................................................................................................................
18
7.2.3 Carbon Monoxide
..................................................................................................................................
19
7.2.4 Oxides of Nitrogen
................................................................................................................................
20
-
EASTLINK VENTILATION STACK EMISSION MONITORING REPORT: OCTOBER -
DECEMBER 2011
January 2012 Report No. 097613024-020-R-Rev0 ii
7.2.4.1 Nitric Oxide
........................................................................................................................................
20
7.2.4.2 Nitrogen Dioxide
................................................................................................................................
21
7.2.5 Stack Velocity
.......................................................................................................................................
22
7.3 Data Validation and Exceptions
..................................................................................................................
23
8.0 VENTILATION STACK EMISSION MONITORING PERIOD:
01/12/2011 – 31/12/2011 .........................................
24
8.1 Data Capture
..............................................................................................................................................
24
8.2 Results
........................................................................................................................................................
25
8.2.1 PM2.5
.....................................................................................................................................................
25
8.2.2 PM10
......................................................................................................................................................
26
8.2.3 Carbon Monoxide
..................................................................................................................................
27
8.2.4 Oxides of Nitrogen
................................................................................................................................
28
8.2.4.1 Nitric Oxide
........................................................................................................................................
28
8.2.4.2 Nitrogen Dioxide
................................................................................................................................
29
8.2.5 Stack Velocity
.......................................................................................................................................
30
8.3 Data Validation and Exceptions
..................................................................................................................
31
9.0 DISCUSSION
...........................................................................................................................................................
32
9.1 Comparison with Licence Limits
.................................................................................................................
32
TABLES Table 1: Discharges to Air
...................................................................................................................................................
2
Table 2: Measurement Uncertainty
.....................................................................................................................................
6
Table 3: Data Capture Statistics - 1 Hour Averages
............................................................................................................
7
Table 4: PM2.5 Mass Rate Percentiles (1 Hour Average)
.....................................................................................................
8
Table 5: PM10 Mass Rate Percentiles (1 Hour Average)
.....................................................................................................
9
Table 6: Carbon Monoxide Mass Rate Percentiles (1 Hour Average)
...............................................................................
10
Table 7: Nitric Oxide Mass Rate Percentiles (1 Hour Average)
.........................................................................................
11
Table 8: Nitrogen Dioxide Mass Rate Percentiles (1 Hour Average)
.................................................................................
12
Table 9: Data Exceptions - Eastern Ventilation Stack: October
2011
...............................................................................
14
Table 10: Data Exceptions - Western Ventilation Stack: October
2011
............................................................................
15
Table 11: Data Capture Statistics - 1 Hour Averages
........................................................................................................
16
Table 12: PM2.5 Mass Rate Percentiles (1 Hour Average)
.................................................................................................
17
Table 13: PM10 Mass Rate Percentiles (1 Hour Average)
.................................................................................................
18
Table 14: Carbon Monoxide Mass Rate Percentiles (1 Hour Average)
.............................................................................
19
-
EASTLINK VENTILATION STACK EMISSION MONITORING REPORT: OCTOBER -
DECEMBER 2011
January 2012 Report No. 097613024-020-R-Rev0 iii
Table 15: Nitric Oxide Mass Rate Percentiles (1 Hour Average)
.......................................................................................
20
Table 16: Nitrogen Dioxide Mass Rate Percentiles (1 Hour
Average)
...............................................................................
21
Table 17: Data Exceptions - Eastern Ventilation Stack: November
2011
..........................................................................
23
Table 18: Data Exceptions - Western Ventilation Stack: November
2011
.........................................................................
23
Table 19: Data Capture Statistics - 1 Hour Averages
........................................................................................................
24
Table 20: PM2.5 Mass Rate Percentiles (1 Hour Average)
................................................................................................
25
Table 21: PM10 Mass Rate Percentiles (1 Hour Average)
.................................................................................................
26
Table 22: Carbon Monoxide Mass Rate Percentiles (1 Hour Average)
.............................................................................
27
Table 23: Nitric Oxide Mass Rate Percentiles (1 Hour Average)
.......................................................................................
28
Table 24: Nitrogen Dioxide Mass Rate Percentiles (1 Hour
Average)
...............................................................................
29
Table 25: Data Exceptions - Eastern Ventilation Stack: December
2011
..........................................................................
31
Table 26: Data Exceptions - Western Ventilation Stack: December
2011
.........................................................................
31
Table 27: Maximum (1 Hour Average) Mass Rate (01/10/2011 -
31/12/2011)
..................................................................
32
Table 28: Data Capture Year to Date (%)
.........................................................................................................................
32
FIGURES Figure 1: Ventilation Stack Locations
..................................................................................................................................
2
Figure 2: PM2.5 Mass Rate (1 Hour Average)
......................................................................................................................
8
Figure 3: PM10 Mass Rate (1 Hour Average)
......................................................................................................................
9
Figure 4: Carbon Monoxide Mass Rate (1 Hour Average)
................................................................................................
10
Figure 5: Nitric Oxide Mass Rate (1 Hour Average)
..........................................................................................................
11
Figure 6: Nitrogen Dioxide Mass Rate (1 Hour Average)
..................................................................................................
12
Figure 7: Stack Velocity (1 Hour Average)
........................................................................................................................
13
Figure 8: PM2.5 Mass Rate (1 Hour Average)
....................................................................................................................
17
Figure 9: PM10 Mass Rate (1 Hour Average)
....................................................................................................................
18
Figure 10: Carbon Monoxide Mass Rate (1 Hour Average)
..............................................................................................
19
Figure 11: Nitric Oxide Mass Rate (1 Hour Average)
........................................................................................................
20
Figure 12: Nitrogen Dioxide Mass Rate (1 Hour Average)
................................................................................................
21
Figure 13: Stack Velocity (1 Hour Average)
......................................................................................................................
22
Figure 14: PM2.5 Mass Rate (1 Hour Average)
..................................................................................................................
25
Figure 15: PM10 Mass Rate (1 Hour Average)
..................................................................................................................
26
Figure 16: Carbon Monoxide Mass Rate (1 Hour Average)
..............................................................................................
27
Figure 17: Nitric Oxide Mass Rate (1 Hour Average)
........................................................................................................
28
Figure 18: Nitrogen Dioxide Mass Rate (1 Hour Average)
................................................................................................
29
Figure 19: Stack Velocity (1 Hour Average)
......................................................................................................................
30
-
EASTLINK VENTILATION STACK EMISSION MONITORING REPORT: OCTOBER -
DECEMBER 2011
January 2012 Report No. 097613024-020-R-Rev0 1
1.0 INTRODUCTION
EastLink is a 39-kilometre motorway running between Donvale in
Melbourne’s north-east to Frankston in Melbourne’s south-east with
two tunnels under the Mullum Mullum Valley. Transfield Services,
who are responsible for operation and maintenance of the road,
commissioned Golder Associates Pty. Ltd. to provide continuous
emission monitoring services for the EastLink motorway project. The
services provided include:
Operations and maintenance services for the EastLink ventilation
stack continuous emission monitoring systems (CEMS)
NATA endorsed emission monitoring reports. Monitoring commenced
on the 29th June, 2008 with the opening of the EastLink motorway.
Results for the sampling period 1st October, 2011 to 31st December,
2011 inclusive are contained in the following report.
-
EASTLINK VENTILATION STACK EMISSION MONITORING REPORT: OCTOBER -
DECEMBER 2011
January 2012 Report No. 097613024-020-R-Rev0 2
2.0 DISCHARGES TO AIR
EastLink has discharges to air servicing two road tunnels.
Discharge Point No. 1 (DP1) services the inbound (Melba) tunnel and
Discharge Point No. 2 (DP2) services the outbound (Mullum Mullum)
tunnel.
The locations of the discharges to air are described in Table 1
and presented in Figure 1.
Table 1: Discharges to Air Discharge Point No. Station Name
Location
1 Western ventilation stack Western end of inbound tunnel
(Melba) - Donvale
2 Eastern ventilation stack Eastern end of outbound tunnel
(Mullum Mullum) – Ringwood
Monitoring equipment is housed in temperature controlled
cabinets located at the base of each of the ventilation stacks.
Particulate and gaseous sample inlets are installed inside the
plenum chamber of each of the ventilation stacks.
Figure 1: Ventilation Stack Locations
DP 1 – Western Ventilation Stack
DP 2 – Eastern Ventilation Stack
Source: Google Earth Pro 2009 – Image dated 1 1 2009 supplied by
and sourced under licence from
Google Earth Pro on 18 07 11. Image geo-referenced by Golder and
intended for indicative purposes
only.
-
EASTLINK VENTILATION STACK EMISSION MONITORING REPORT: OCTOBER -
DECEMBER 2011
January 2012 Report No. 097613024-020-R-Rev0 3
3.0 VENTILATION STACK MONITORING PARAMETERS
The following parameters are monitored continuously, with
averages logged at 5 minute intervals:
Particulate matter with an equivalent aerodynamic diameter less
than 2.5 microns (PM2.5) Particulate matter with an equivalent
aerodynamic diameter less than 10 microns (PM10) Total oxides of
nitrogen (NOx) Nitric oxide (NO) Nitrogen dioxide (NO2) Carbon
monoxide (CO) Stack velocity Stack temperature Ambient
pressure.
-
EASTLINK VENTILATION STACK EMISSION MONITORING REPORT: OCTOBER -
DECEMBER 2011
January 2012 Report No. 097613024-020-R-Rev0 4
4.0 METHODS 4.1 PM2.5 PM2.5 concentrations in the tunnel
ventilation stacks are determined using a 1400 Series Tapered
Element Oscillating Microbalance (TEOM) analyser, located in the
plenum chamber of the ventilation stacks.
Exhaust gas is drawn through a PM2.5 size selective inlet (PM10
WINS head fitted with a PM2.5 sharp cut cyclone (SCC)) at 1 m3/h.
The flow is then isokinetically split into two streams; 1 l/min
stream which passes through the filter on the mass transducer and a
15.7 l/min bypass stream.
The sample stream is heated to 50°C to maintain a low and
therefore relatively constant humidity.
Measurements are made in real-time (2 s intervals) with the
5-minute averages logged. 1-hour averages are then calculated from
the logged data.
The PM2.5 monitoring method is based on the requirements of
Australian Standard AS 3580.9.8, “Methods for Sampling and Analysis
of Ambient Air: Determination of Suspended Particulate Matter –
PM10 Continuous Direct Mass Method Using a Tapered Element
Oscillating Microbalance Analyser”.
4.2 PM10 PM10 concentrations in the tunnel ventilation stacks
are determined using a 1400 Series Tapered Element Oscillating
Microbalance (TEOM) analyser, located in the plenum chamber of the
ventilation stacks.
Exhaust gas is drawn through a PM10 size selective inlet (PM10
WINS head) at 1 m3/h. The flow is then isokinetically split into
two streams; 1 l/min stream which passes through the filter on the
mass transducer and a 15.7 l/min bypass stream.
The sample stream is heated to 50°C to maintain a low and
therefore relatively constant humidity.
Measurements are made in real-time (2 s intervals) with the
5-minute averages logged. 1-hour averages are then calculated from
the logged data.
The PM10 monitoring method is based on the requirements of
Australian Standard AS 3580.9.8, “Methods for Sampling and Analysis
of Ambient Air: Determination of Suspended Particulate Matter –
PM10 Continuous Direct Mass Method Using a Tapered Element
Oscillating Microbalance Analyser”.
4.3 Carbon Monoxide Carbon monoxide concentrations in the tunnel
ventilation stacks are determined by infra-red gas filter
correlation analysers.
Automatic calibrations are carried out daily against a NATA
certified reference gas mixture. Manual calibrations are conducted
at one month intervals.
The carbon monoxide monitoring method is based on the
requirements of Australian Standard AS 3580.7.1, “Determination of
Carbon Monoxide – Direct Reading Instrumental Method”.
-
EASTLINK VENTILATION STACK EMISSION MONITORING REPORT: OCTOBER -
DECEMBER 2011
January 2012 Report No. 097613024-020-R-Rev0 5
4.4 Oxides of Nitrogen Oxides of nitrogen concentrations in the
tunnel ventilation stacks are determined by chemiluminescence gas
analysers.
Automatic calibrations are carried out daily against a NATA
certified reference gas mixture. Manual calibrations are conducted
at one month intervals.
The oxides of nitrogen (NO, NO2 and NOx) monitoring method is
based on the requirements of Australian Standard AS 3580.5.1,
“Determination of Oxides of Nitrogen – Chemiluminescence
Method”.
4.5 Stack Velocity Stack gas velocity was determined using an
optical flow sensor that complies with USEPA Code of Federal
Regulations (CFR 40) Part 75, “Continuous Emission Monitoring”
requirements.
-
EASTLINK VENTILATION STACK EMISSION MONITORING REPORT: OCTOBER -
DECEMBER 2011
January 2012 Report No. 097613024-020-R-Rev0 6
5.0 MEASUREMENT UNCERTAINTY
Table 2: Measurement Uncertainty Parameter Method Estimated
Uncertainty
PM10 TEOM ± 5%
PM2.5 TEOM ± 5%
NO, NO2, NOX Chemiluminescence ± 10%
CO Infra-red gas filter correlation ± 10%
Stack velocity Optical flow sensor ± 0.1 m/s or 5% of reading,
whichever is greater
-
EASTLINK VENTILATION STACK EMISSION MONITORING REPORT: OCTOBER -
DECEMBER 2011
January 2012 Report No. 097613024-020-R-Rev0 7
6.0 VENTILATION STACK EMISSION MONITORING PERIOD: 01/10/2011 –
31/10/2011
6.1 Data Capture Data capture is defined as the number of valid
data periods collected divided by the number of available data
periods. Valid data excludes periods where the instrument is
unavailable due to calibration and maintenance and excludes periods
where the data has been rejected due to quality assurance/data
validation procedures.
The data capture statistics for the reporting period 1st October
to 31st October, 2011 are shown in Table 3. Averages were only
collected for those periods where the 5-minute data constituted 75%
data capture.
Section 6.3 provides further information on the reasons for
invalid data periods.
Table 3: Data Capture Statistics - 1 Hour Averages
Parameter Station Collected Periods Available Periods Data
Capture
PM2.5 Eastern 704 744 94.6%
Western 743 744 99.9%
PM10 Eastern 742 744 99.7%
Western 741 744 99.6%
NO, NO2 Eastern 711 744 95.6%
Western 639 744 85.9%
CO Eastern 711 744 95.6%
Western 661 744 88.8%
-
EASTLINK VENTILATION STACK EMISSION MONITORING REPORT: OCTOBER -
DECEMBER 2011
January 2012 Report No. 097613024-020-R-Rev0 8
6.2 Results
6.2.1 PM2.5 PM2.5 was continuously monitored and 5 minute
averages logged. The 5 minute average data was then transformed to
1 hour averages for reporting.
PM2.5 (1 hour average) mass rate of emission statistics for the
reporting period are given in Table 4. A plot of PM2.5 (1 hour
average) mass rate of emission for the reporting period is
presented in Figure 2.
Table 4: PM2.5 Mass Rate Percentiles (1 Hour Average)
Station PM2.5 Mass Rate (kg/h) (1-Hour Average)
Maximum 99th 98th 95th 90th 75th 50th
Eastern 0.29 0.24 0.23 0.20 0.19 0.14 0.04
Western 0.27 0.21 0.19 0.15 0.12 0.09 0.03
Figure 2: PM2.5 Mass Rate (1 Hour Average)
0.0
0.5
1.0
1.5
2.0
2.5
3.0
1-O
ct
2-O
ct
3-O
ct
4-O
ct
5-O
ct
6-O
ct
7-O
ct
8-O
ct
9-O
ct
10-O
ct
11-O
ct
12-O
ct
13-O
ct
14-O
ct
15-O
ct
16-O
ct
17-O
ct
18-O
ct
19-O
ct
20-O
ct
21-O
ct
22-O
ct
23-O
ct
24-O
ct
25-O
ct
26-O
ct
27-O
ct
28-O
ct
29-O
ct
30-O
ct
31-O
ct
PM
2.5
(kg/
hour
)
Date
East Stack West Stack Limit
-
EASTLINK VENTILATION STACK EMISSION MONITORING REPORT: OCTOBER -
DECEMBER 2011
January 2012 Report No. 097613024-020-R-Rev0 9
6.2.2 PM10 PM10 was continuously monitored and 5 minute averages
logged. The 5 minute average data was then transformed to 1 hour
averages for reporting.
PM10 (1 hour average) mass rate of emission statistics for the
reporting period are given in Table 5. A plot of PM10 (1 hour
average) mass rate of emission for the reporting period is
presented in Figure 3.
Table 5: PM10 Mass Rate Percentiles (1 Hour Average)
Station PM10 Mass Rate (kg/h) (1-Hour Average)
Maximum 99th 98th 95th 90th 75th 50th
Eastern 0.33 0.30 0.29 0.26 0.23 0.19 0.06
Western 0.94 0.31 0.29 0.22 0.18 0.13 0.05
Figure 3: PM10 Mass Rate (1 Hour Average)
0.0
0.5
1.0
1.5
2.0
2.5
3.0
1-O
ct
2-O
ct
3-O
ct
4-O
ct
5-O
ct
6-O
ct
7-O
ct
8-O
ct
9-O
ct
10-O
ct
11-O
ct
12-O
ct
13-O
ct
14-O
ct
15-O
ct
16-O
ct
17-O
ct
18-O
ct
19-O
ct
20-O
ct
21-O
ct
22-O
ct
23-O
ct
24-O
ct
25-O
ct
26-O
ct
27-O
ct
28-O
ct
29-O
ct
30-O
ct
31-O
ct
PM10
(kg/
hour
)
Date
East Stack West Stack Limit
-
EASTLINK VENTILATION STACK EMISSION MONITORING REPORT: OCTOBER -
DECEMBER 2011
January 2012 Report No. 097613024-020-R-Rev0 10
6.2.3 Carbon Monoxide Carbon monoxide (1 hour average) mass rate
of emission statistics for the reporting period are given in Table
6. A plot of carbon monoxide (1 hour average) mass rate of emission
for the reporting period is presented in Figure 4.
Table 6: Carbon Monoxide Mass Rate Percentiles (1 Hour
Average)
Station Carbon Monoxide Mass Rate (kg/h) (1-Hour Average)
Maximum 99th 98th 95th 90th 75th 50th
Eastern 25 22 20 18 13 10 6.6
Western 22 19 17 13 10 7 4.8
Figure 4: Carbon Monoxide Mass Rate (1 Hour Average)
0
20
40
60
80
100
120
1-O
ct
2-O
ct
3-O
ct
4-O
ct
5-O
ct
6-O
ct
7-O
ct
8-O
ct
9-O
ct
10-O
ct
11-O
ct
12-O
ct
13-O
ct
14-O
ct
15-O
ct
16-O
ct
17-O
ct
18-O
ct
19-O
ct
20-O
ct
21-O
ct
22-O
ct
23-O
ct
24-O
ct
25-O
ct
26-O
ct
27-O
ct
28-O
ct
29-O
ct
30-O
ct
31-O
ct
CO
(kg/
hour
)
Date
East Stack West Stack Limit
-
EASTLINK VENTILATION STACK EMISSION MONITORING REPORT: OCTOBER -
DECEMBER 2011
January 2012 Report No. 097613024-020-R-Rev0 11
6.2.4 Oxides of Nitrogen 6.2.4.1 Nitric Oxide Nitric oxide (1
hour average) mass rate of emission statistics for the reporting
period are given in Table 7. A plot of nitric oxide (1 hour
average) mass rate of emission for the reporting period is
presented in Figure 5.
Table 7: Nitric Oxide Mass Rate Percentiles (1 Hour Average)
Station Nitric Oxide Mass Rate (kg/h) (1-Hour Average)
Maximum 99th 98th 95th 90th 75th 50th
Eastern 4.2 3.6 3.5 3.2 2.7 2.2 1.0
Western 5.5 4.5 4.1 3.2 2.6 2.0 1.1
Figure 5: Nitric Oxide Mass Rate (1 Hour Average)
0
5
10
15
20
25
30
35
40
45
50
1-O
ct
2-O
ct
3-O
ct
4-O
ct
5-O
ct
6-O
ct
7-O
ct
8-O
ct
9-O
ct
10-O
ct
11-O
ct
12-O
ct
13-O
ct
14-O
ct
15-O
ct
16-O
ct
17-O
ct
18-O
ct
19-O
ct
20-O
ct
21-O
ct
22-O
ct
23-O
ct
24-O
ct
25-O
ct
26-O
ct
27-O
ct
28-O
ct
29-O
ct
30-O
ct
31-O
ct
NO
(kg/
hour
)
Date
East Stack West Stack
-
EASTLINK VENTILATION STACK EMISSION MONITORING REPORT: OCTOBER -
DECEMBER 2011
January 2012 Report No. 097613024-020-R-Rev0 12
6.2.4.2 Nitrogen Dioxide Nitrogen dioxide (1 hour average) mass
rate of emission statistics for the reporting period are given in
Table 8. A plot of nitrogen dioxide (1 hour average) mass rate of
emission for the reporting period is presented in Figure 6.
Table 8: Nitrogen Dioxide Mass Rate Percentiles (1 Hour
Average)
Station Nitrogen Dioxide Mass Rate (kg/h) (1-Hour Average)
Maximum 99th 98th 95th 90th 75th 50th
Eastern 0.5 0.5 0.4 0.4 0.3 0.2 0.1
Western 0.4 0.3 0.3 0.3 0.2 0.2 0.1
Figure 6: Nitrogen Dioxide Mass Rate (1 Hour Average)
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
1-O
ct
2-O
ct
3-O
ct
4-O
ct
5-O
ct
6-O
ct
7-O
ct
8-O
ct
9-O
ct
10-O
ct
11-O
ct
12-O
ct
13-O
ct
14-O
ct
15-O
ct
16-O
ct
17-O
ct
18-O
ct
19-O
ct
20-O
ct
21-O
ct
22-O
ct
23-O
ct
24-O
ct
25-O
ct
26-O
ct
27-O
ct
28-O
ct
29-O
ct
30-O
ct
31-O
ct
NO
2(k
g/ho
ur)
Date
East Stack West Stack Limit
-
EASTLINK VENTILATION STACK EMISSION MONITORING REPORT: OCTOBER -
DECEMBER 2011
January 2012 Report No. 097613024-020-R-Rev0 13
6.2.5 Stack Velocity The stack velocity (1 hour average) plot
for the reporting period is presented in Figure 7.
Figure 7: Stack Velocity (1 Hour Average)
0
2
4
6
8
10
12
14
16
18
1-O
ct
2-O
ct
3-O
ct
4-O
ct
5-O
ct
6-O
ct
7-O
ct
8-O
ct
9-O
ct
10-O
ct
11-O
ct
12-O
ct
13-O
ct
14-O
ct
15-O
ct
16-O
ct
17-O
ct
18-O
ct
19-O
ct
20-O
ct
21-O
ct
22-O
ct
23-O
ct
24-O
ct
25-O
ct
26-O
ct
27-O
ct
28-O
ct
29-O
ct
30-O
ct
31-O
ct
Vel
ocity
(m/s
)
Date
East Stack West Stack
-
EASTLINK VENTILATION STACK EMISSION MONITORING REPORT: OCTOBER -
DECEMBER 2011
January 2012 Report No. 097613024-020-R-Rev0 14
6.3 Data Validation and Exceptions Data contained in the report
has been validated against performance and calibration requirements
for each instrument. Data during maintenance and calibration
periods has been removed from the validated data sets. Tables 9 and
10 list the data exceptions for the eastern and western ventilation
stacks respectively. Data during automatic calibrations of the
gaseous atmospheric contaminants has also been removed from the
data sets.
Table 9: Data Exceptions - Eastern Ventilation Stack: October
2011 Start End Parameter Reason
28/10/2011 12:45 28/10/2011 13:05 NO, NO2, NOx
Maintenance/calibration
17/10/2011 12:40 17/10/2011 12:55 CO Maintenance/calibration
17/10/2011 13:15 17/10/2011 13:40 CO Maintenance/calibration
28/10/2011 12:45 28/10/2011 13:05 CO Maintenance/calibration
10/10/2011 8:10 10/10/2011 8:25 PM2.5 Invalid data1
12/10/2011 10:10 12/10/2011 10:25 PM2.5 Invalid data1
13/10/2011 12:35 13/10/2011 12:50 PM2.5 Invalid data1
14/10/2011 13:40 14/10/2011 13:55 PM2.5 Invalid data1
15/10/2011 16:00 15/10/2011 16:20 PM2.5 Invalid data1
16/10/2011 3:00 16/10/2011 20:55 PM2.5 Invalid data1
16/10/2011 22:10 16/10/2011 22:35 PM2.5 Invalid data1
17/10/2011 5:45 17/10/2011 5:55 PM2.5 Invalid data1
17/10/2011 7:20 17/10/2011 7:30 PM2.5 Invalid data1
17/10/2011 10:50 17/10/2011 11:05 PM2.5 Invalid data1
17/10/2011 13:05 17/10/2011 13:50 PM2.5
Maintenance/calibration
18/10/2011 3:00 18/10/2011 3:20 PM2.5 Invalid data1
18/10/2011 15:30 18/10/2011 15:40 PM2.5 Invalid data1
23/10/2011 16:00 23/10/2011 16:15 PM2.5 Invalid data1
27/10/2011 10:20 27/10/2011 10:35 PM2.5 Invalid data1
27/10/2011 13:25 27/10/2011 17:40 PM2.5 Invalid data1
27/10/2011 19:40 27/10/2011 20:15 PM2.5 Invalid data1
28/10/2011 12:20 28/10/2011 13:00 PM2.5
Maintenance/calibration
17/10/2011 13:05 17/10/2011 14:10 PM10
Maintenance/calibration
28/10/2011 12:35 28/10/2011 13:00 PM10
Maintenance/calibration
Note: 1 – In the opinion of the reviewer.
-
EASTLINK VENTILATION STACK EMISSION MONITORING REPORT: OCTOBER -
DECEMBER 2011
January 2012 Report No. 097613024-020-R-Rev0 15
Table 10: Data Exceptions - Western Ventilation Stack: October
2011 Start End Parameter Reason
3/10/2011 9:45 3/10/2011 10:00 NO, NO2, NOx
Maintenance/calibration
3/10/2011 22:00 3/10/2011 23:55 CO Invalid data1
4/10/2011 13:45 6/10/2011 13:15 CO Invalid data - Span drift
5/10/2011 13:25 5/10/2011 13:55 NO, NO2, NOx
Maintenance/calibration
9/10/2011 0:40 10/10/2011 9:55 NO, NO2, NOx Invalid data - Span
drift
10/10/2011 9:55 10/10/2011 10:20 NO, NO2, NOx
Maintenance/calibration
10/10/2011 10:25 10/10/2011 10:50 CO Maintenance/calibration
17/10/2011 9:50 17/10/2011 10:20 CO Maintenance/calibration
17/10/2011 10:15 17/10/2011 11:10 PM2.5
Maintenance/calibration
17/10/2011 10:30 17/10/2011 10:50 NO, NO2, NOx
Maintenance/calibration
17/10/2011 10:35 17/10/2011 11:25 PM10
Maintenance/calibration
17/10/2011 11:10 17/10/2011 11:30 CO Maintenance/calibration
17/10/2011 11:35 17/10/2011 12:00 NO, NO2, NOx
Maintenance/calibration
24/10/2011 0:40 25/10/2011 14:50 NO, NO2, NOx Invalid data -
Span drift
25/10/2011 14:50 25/10/2011 15:05 NO, NO2, NOx
Maintenance/calibration
26/10/2011 10:00 26/10/2011 10:25 CO Maintenance/calibration
31/10/2011 12:15 31/10/2011 12:40 NO, NO2, NOx
Maintenance/calibration
31/10/2011 18:15 31/10/2011 18:30 PM10 Invalid data1
Note: 1 – In the opinion of the reviewer.
-
EASTLINK VENTILATION STACK EMISSION MONITORING REPORT: OCTOBER -
DECEMBER 2011
January 2012 Report No. 097613024-020-R-Rev0 16
7.0 VENTILATION STACK EMISSION MONITORING PERIOD: 01/11/2011 –
30/11/2011
7.1 Data Capture Data capture is defined as the number of valid
data periods collected divided by the number of available data
periods. Valid data excludes periods where the instrument is
unavailable due to calibration and maintenance and excludes periods
where the data has been rejected due to quality assurance/data
validation procedures.
The data capture statistics for the reporting period 1st
November to 30th November, 2011 are shown in Table 11. Averages
were only collected for those periods where the 5-minute data
constituted 75% data capture.
Section 7.3 provides further information on the reasons for
invalid data periods.
Table 11: Data Capture Statistics - 1 Hour Averages
Parameter Station Collected Periods Available Periods Data
Capture
PM2.5 Eastern 715 720 99.3%
Western 718 720 99.7%
PM10 Eastern 716 720 99.4%
Western 719 720 99.9%
NO, NO2 Eastern 690 720 95.8%
Western 685 720 95.1%
CO Eastern 690 720 95.8%
Western 686 720 95.3%
-
EASTLINK VENTILATION STACK EMISSION MONITORING REPORT: OCTOBER -
DECEMBER 2011
January 2012 Report No. 097613024-020-R-Rev0 17
7.2 Results
7.2.1 PM2.5 PM2.5 was continuously monitored and 5 minute
averages logged. The 5 minute average data was then transformed to
1 hour averages for reporting.
PM2.5 (1 hour average) mass rate of emission statistics for the
reporting period are given in Table 12. A plot of PM2.5 (1 hour
average) mass rate of emission for the reporting period is
presented in Figure 8.
Table 12: PM2.5 Mass Rate Percentiles (1 Hour Average)
Station PM2.5 Mass Rate (kg/h) (1-Hour Average)
Maximum 99th 98th 95th 90th 75th 50th
Eastern 0.32 0.28 0.25 0.21 0.19 0.15 0.05
Western 0.31 0.24 0.22 0.18 0.14 0.10 0.03
Figure 8: PM2.5 Mass Rate (1 Hour Average)
0.0
0.5
1.0
1.5
2.0
2.5
3.0
1-N
ov
2-N
ov
3-N
ov
4-N
ov
5-N
ov
6-N
ov
7-N
ov
8-N
ov
9-N
ov
10-N
ov
11-N
ov
12-N
ov
13-N
ov
14-N
ov
15-N
ov
16-N
ov
17-N
ov
18-N
ov
19-N
ov
20-N
ov
21-N
ov
22-N
ov
23-N
ov
24-N
ov
25-N
ov
26-N
ov
27-N
ov
28-N
ov
29-N
ov
30-N
ov
PM
2.5
(kg/
hour
)
Date
East Stack West Stack Limit
-
EASTLINK VENTILATION STACK EMISSION MONITORING REPORT: OCTOBER -
DECEMBER 2011
January 2012 Report No. 097613024-020-R-Rev0 18
7.2.2 PM10 PM10 was continuously monitored and 5-minute averages
logged. The 5 minute average data was then transformed to 1 hour
averages for reporting.
PM10 (1 hour average) mass rate of emission statistics for the
reporting period are given in Table 13. A plot of PM10 (1 hour
average) mass rate of emission for the reporting period is
presented in Figure 9.
Table 13: PM10 Mass Rate Percentiles (1 Hour Average)
Station PM10 Mass Rate (kg/h) (1-Hour Average)
Maximum 99th 98th 95th 90th 75th 50th
Eastern 0.78 0.32 0.31 0.28 0.25 0.20 0.06
Western 0.46 0.30 0.27 0.21 0.19 0.13 0.05
Figure 9: PM10 Mass Rate (1 Hour Average)
0.0
0.5
1.0
1.5
2.0
2.5
3.0
1-N
ov
2-N
ov
3-N
ov
4-N
ov
5-N
ov
6-N
ov
7-N
ov
8-N
ov
9-N
ov
10-N
ov
11-N
ov
12-N
ov
13-N
ov
14-N
ov
15-N
ov
16-N
ov
17-N
ov
18-N
ov
19-N
ov
20-N
ov
21-N
ov
22-N
ov
23-N
ov
24-N
ov
25-N
ov
26-N
ov
27-N
ov
28-N
ov
29-N
ov
30-N
ov
PM10
(kg/
hour
)
Date
East Stack West Stack Limit
-
EASTLINK VENTILATION STACK EMISSION MONITORING REPORT: OCTOBER -
DECEMBER 2011
January 2012 Report No. 097613024-020-R-Rev0 19
7.2.3 Carbon Monoxide Carbon monoxide (1 hour average) mass rate
of emission statistics for the reporting period are given in Table
14. A plot of carbon monoxide (1 hour average) mass rate of
emission for the reporting period is presented in Figure 10.
Table 14: Carbon Monoxide Mass Rate Percentiles (1 Hour
Average)
Station Carbon Monoxide Mass Rate (kg/h) (1-Hour Average)
Maximum 99th 98th 95th 90th 75th 50th
Eastern 32 24 22 20 14 11 7.5
Western 25 21 19 15 12 9 6.3
Figure 10: Carbon Monoxide Mass Rate (1 Hour Average)
0
20
40
60
80
100
120
1-N
ov
2-N
ov
3-N
ov
4-N
ov
5-N
ov
6-N
ov
7-N
ov
8-N
ov
9-N
ov
10-N
ov
11-N
ov
12-N
ov
13-N
ov
14-N
ov
15-N
ov
16-N
ov
17-N
ov
18-N
ov
19-N
ov
20-N
ov
21-N
ov
22-N
ov
23-N
ov
24-N
ov
25-N
ov
26-N
ov
27-N
ov
28-N
ov
29-N
ov
30-N
ov
CO
(kg/
hour
)
Date
East Stack West Stack Limit
-
EASTLINK VENTILATION STACK EMISSION MONITORING REPORT: OCTOBER -
DECEMBER 2011
January 2012 Report No. 097613024-020-R-Rev0 20
7.2.4 Oxides of Nitrogen 7.2.4.1 Nitric Oxide Nitric oxide
(1-hour average) mass rate of emission statistics for the reporting
period are given in Table 15. A plot of nitric oxide (1-hour
average) mass rate of emission for the reporting period is
presented in Figure 11.
Table 15: Nitric Oxide Mass Rate Percentiles (1 Hour
Average)
Station Nitric Oxide Mass Rate (kg/h) (1-Hour Average)
Maximum 99th 98th 95th 90th 75th 50th
Eastern 3.9 3.8 3.6 3.3 2.7 2.3 1.1
Western 4.8 4.2 4.0 2.9 2.6 2.1 1.1
Figure 11: Nitric Oxide Mass Rate (1 Hour Average)
0
5
10
15
20
25
30
35
40
45
50
1-N
ov
2-N
ov
3-N
ov
4-N
ov
5-N
ov
6-N
ov
7-N
ov
8-N
ov
9-N
ov
10-N
ov
11-N
ov
12-N
ov
13-N
ov
14-N
ov
15-N
ov
16-N
ov
17-N
ov
18-N
ov
19-N
ov
20-N
ov
21-N
ov
22-N
ov
23-N
ov
24-N
ov
25-N
ov
26-N
ov
27-N
ov
28-N
ov
29-N
ov
30-N
ov
NO
(kg/
hour
)
Date
East Stack West Stack
-
EASTLINK VENTILATION STACK EMISSION MONITORING REPORT: OCTOBER -
DECEMBER 2011
January 2012 Report No. 097613024-020-R-Rev0 21
7.2.4.2 Nitrogen Dioxide Nitrogen dioxide (1 hour average) mass
rate of emission statistics for the reporting period are given in
Table 16. A plot of nitrogen dioxide (1 hour average) mass rate of
emission for the reporting period is presented in Figure 12.
Table 16: Nitrogen Dioxide Mass Rate Percentiles (1 Hour
Average)
Station Nitrogen Dioxide Mass Rate (kg/h) (1-Hour Average)
Maximum 99th 98th 95th 90th 75th 50th
Eastern 0.6 0.5 0.5 0.4 0.3 0.2 0.1
Western 0.4 0.3 0.3 0.2 0.2 0.2 0.1
Figure 12: Nitrogen Dioxide Mass Rate (1 Hour Average)
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
1-N
ov
2-N
ov
3-N
ov
4-N
ov
5-N
ov
6-N
ov
7-N
ov
8-N
ov
9-N
ov
10-N
ov
11-N
ov
12-N
ov
13-N
ov
14-N
ov
15-N
ov
16-N
ov
17-N
ov
18-N
ov
19-N
ov
20-N
ov
21-N
ov
22-N
ov
23-N
ov
24-N
ov
25-N
ov
26-N
ov
27-N
ov
28-N
ov
29-N
ov
30-N
ov
NO
2(k
g/ho
ur)
Date
East Stack West Stack Limit
-
EASTLINK VENTILATION STACK EMISSION MONITORING REPORT: OCTOBER -
DECEMBER 2011
January 2012 Report No. 097613024-020-R-Rev0 22
7.2.5 Stack Velocity The stack velocity (1 hour average) plot
for the reporting period is presented in Figure 13.
Figure 13: Stack Velocity (1 Hour Average)
0
2
4
6
8
10
12
14
16
18
1-N
ov
2-N
ov
3-N
ov
4-N
ov
5-N
ov
6-N
ov
7-N
ov
8-N
ov
9-N
ov
10-N
ov
11-N
ov
12-N
ov
13-N
ov
14-N
ov
15-N
ov
16-N
ov
17-N
ov
18-N
ov
19-N
ov
20-N
ov
21-N
ov
22-N
ov
23-N
ov
24-N
ov
25-N
ov
26-N
ov
27-N
ov
28-N
ov
29-N
ov
30-N
ov
Velo
city
(m/s
)
Date
East Stack West Stack
-
EASTLINK VENTILATION STACK EMISSION MONITORING REPORT: OCTOBER -
DECEMBER 2011
January 2012 Report No. 097613024-020-R-Rev0 23
7.3 Data Validation and Exceptions Data contained in the report
has been validated against performance and calibration requirements
for each instrument. Data during maintenance and calibration
periods has been removed from the validated data sets. Tables 17
and 18 list the data exceptions for the eastern and western
ventilation stacks respectively. Data during automatic calibrations
of the gaseous atmospheric contaminants has also been removed from
the data sets.
Table 17: Data Exceptions - Eastern Ventilation Stack: November
2011 Start End Parameter Reason
29/11/2011 12:10 29/11/2011 12:20 NO, NO2, NOx
Maintenance/calibration
29/11/2011 12:10 29/11/2011 12:20 CO Maintenance/calibration
29/11/2011 12:35 29/11/2011 15:00 PM2.5
Maintenance/calibration
29/11/2011 13:00 29/11/2011 13:50 PM10
Maintenance/calibration
29/11/2011 14:00 29/11/2011 15:00 PM10
Maintenance/calibration
30/11/2011 9:55 30/11/2011 11:35 PM2.5
Maintenance/calibration
30/11/2011 10:45 30/11/2011 12:15 PM10
Maintenance/calibration
Table 18: Data Exceptions - Western Ventilation Stack: November
2011 Start End Parameter Reason
4/11/2011 8:40 4/11/2011 9:00 CO Maintenance/ calibration
8/11/2011 12:10 8/11/2011 12:40 PM2.5 Invalid data1
14/11/2011 14:05 14/11/2011 14:40 CO Maintenance/calibration
17/11/2011 13:50 17/11/2011 14:15 CO Maintenance/calibration
24/11/2011 13:35 24/11/2011 17:10 NO, NO2, NOx
Maintenance/calibration
28/11/2011 12:40 28/11/2011 13:10 CO Maintenance/calibration
28/11/2011 12:50 28/11/2011 13:45 PM2.5
Maintenance/calibration
28/11/2011 13:05 28/11/2011 13:55 PM10
Maintenance/calibration
28/11/2011 13:10 28/11/2011 13:45 NO, NO2, NOx
Maintenance/calibration
30/11/2011 8:55 30/11/2011 9:00 NO, NO2, NOx Invalid data1
Note: 1 – In the opinion of the reviewer.
-
EASTLINK VENTILATION STACK EMISSION MONITORING REPORT: OCTOBER -
DECEMBER 2011
January 2012 Report No. 097613024-020-R-Rev0 24
8.0 VENTILATION STACK EMISSION MONITORING PERIOD: 01/12/2011 –
31/12/2011
8.1 Data Capture Data capture is defined as the number of valid
data periods collected divided by the number of available data
periods. Valid data excludes periods where the instrument is
unavailable due to calibration and maintenance and excludes periods
where the data has been rejected due to quality assurance/data
validation procedures.
The data capture statistics for the reporting period 1st
December to 31st December, 2011 are shown in Table 19. Averages
were only collected for those periods where the 5 minute data
constituted 75% data capture.
Section 8.3 provides further information on the reasons for
invalid data periods.
Table 19: Data Capture Statistics - 1 Hour Averages
Parameter Station Collected Periods Available Periods Data
Capture
PM2.5 Eastern 735 744 98.8%
Western 742 744 99.7%
PM10 Eastern 742 744 99.7%
Western 727 744 97.7%
NO, NO2 Eastern 649 744 87.2%
Western 585 744 78.6%
CO Eastern 704 744 94.6%
Western 710 744 95.4%
-
EASTLINK VENTILATION STACK EMISSION MONITORING REPORT: OCTOBER -
DECEMBER 2011
January 2012 Report No. 097613024-020-R-Rev0 25
8.2 Results
8.2.1 PM2.5 PM2.5 was continuously monitored and 5-minute
averages logged. The 5-minute average data was then transformed to
1-hour averages for reporting.
PM2.5 (1-hour average) mass rate of emission statistics for the
reporting period are given in Table 20. A plot of PM2.5 (1-hour
average) mass rate of emission for the reporting period is
presented in Figure 14.
Table 20: PM2.5 Mass Rate Percentiles (1 Hour Average)
Station PM2.5 Mass Rate (kg/h) (1-Hour Average)
Maximum 99th 98th 95th 90th 75th 50th
Eastern 0.37 0.30 0.28 0.24 0.20 0.14 0.05
Western 0.34 0.22 0.20 0.17 0.14 0.09 0.03
Figure 14: PM2.5 Mass Rate (1 Hour Average)
0.0
0.5
1.0
1.5
2.0
2.5
3.0
1-D
ec
2-D
ec
3-D
ec
4-D
ec
5-D
ec
6-D
ec
7-D
ec
8-D
ec
9-D
ec
10-D
ec
11-D
ec
12-D
ec
13-D
ec
14-D
ec
15-D
ec
16-D
ec
17-D
ec
18-D
ec
19-D
ec
20-D
ec
21-D
ec
22-D
ec
23-D
ec
24-D
ec
25-D
ec
26-D
ec
27-D
ec
28-D
ec
29-D
ec
30-D
ec
31-D
ec
PM
2.5
(kg/
hour
)
Date
East Stack West Stack Limit
-
EASTLINK VENTILATION STACK EMISSION MONITORING REPORT: OCTOBER -
DECEMBER 2011
January 2012 Report No. 097613024-020-R-Rev0 26
8.2.2 PM10 PM10 was continuously monitored and 5 minute averages
logged. The 5 minute average data was then transformed to 1-hour
averages for reporting.
PM10 (1 hour average) mass rate of emission statistics for the
reporting period are given in Table 21. A plot of PM10 (1 hour
average) mass rate of emission for the reporting period is
presented in Figure 15.
Table 21: PM10 Mass Rate Percentiles (1 Hour Average)
Station PM10 Mass Rate (kg/h) (1-Hour Average)
Maximum 99th 98th 95th 90th 75th 50th
Eastern 0.88 0.41 0.36 0.30 0.26 0.16 0.07
Western 0.65 0.35 0.33 0.25 0.21 0.14 0.06
Figure 15: PM10 Mass Rate (1 Hour Average)
0.0
0.5
1.0
1.5
2.0
2.5
3.0
1-D
ec
2-D
ec
3-D
ec
4-D
ec
5-D
ec
6-D
ec
7-D
ec
8-D
ec
9-D
ec
10-D
ec
11-D
ec
12-D
ec
13-D
ec
14-D
ec
15-D
ec
16-D
ec
17-D
ec
18-D
ec
19-D
ec
20-D
ec
21-D
ec
22-D
ec
23-D
ec
24-D
ec
25-D
ec
26-D
ec
27-D
ec
28-D
ec
29-D
ec
30-D
ec
31-D
ec
PM10
(kg/
hour
)
Date
East Stack West Stack Limit
-
EASTLINK VENTILATION STACK EMISSION MONITORING REPORT: OCTOBER -
DECEMBER 2011
January 2012 Report No. 097613024-020-R-Rev0 27
8.2.3 Carbon Monoxide Carbon monoxide (1 hour average) mass rate
of emission statistics for the reporting period are given in Table
22. A plot of carbon monoxide (1 hour average) mass rate of
emission for the reporting period is presented in Figure 16.
Table 22: Carbon Monoxide Mass Rate Percentiles (1 Hour
Average)
Station Carbon Monoxide Mass Rate (kg/h) (1-Hour Average)
Maximum 99th 98th 95th 90th 75th 50th
Eastern 28 23 21 18 14 11 7.3
Western 29 22 18 14 12 9 5.9
Figure 16: Carbon Monoxide Mass Rate (1 Hour Average)
0
20
40
60
80
100
120
1-D
ec
2-D
ec
3-D
ec
4-D
ec
5-D
ec
6-D
ec
7-D
ec
8-D
ec
9-D
ec
10-D
ec
11-D
ec
12-D
ec
13-D
ec
14-D
ec
15-D
ec
16-D
ec
17-D
ec
18-D
ec
19-D
ec
20-D
ec
21-D
ec
22-D
ec
23-D
ec
24-D
ec
25-D
ec
26-D
ec
27-D
ec
28-D
ec
29-D
ec
30-D
ec
31-D
ec
CO
(kg/
hour
)
Date
East Stack West Stack Limit
-
EASTLINK VENTILATION STACK EMISSION MONITORING REPORT: OCTOBER -
DECEMBER 2011
January 2012 Report No. 097613024-020-R-Rev0 28
8.2.4 Oxides of Nitrogen 8.2.4.1 Nitric Oxide Nitric oxide
(1-hour average) mass rate of emission statistics for the reporting
period are given in Table 23. A plot of nitric oxide (1-hour
average) mass rate of emission for the reporting period is
presented in Figure 17.
Table 23: Nitric Oxide Mass Rate Percentiles (1 Hour
Average)
Station Nitric Oxide Mass Rate (kg/h) (1-Hour Average)
Maximum 99th 98th 95th 90th 75th 50th
Eastern 4.6 3.9 3.6 3.2 2.7 2.0 0.92
Western 6.2 4.6 3.8 3.2 2.7 1.9 0.97
Figure 17: Nitric Oxide Mass Rate (1 Hour Average)
0
5
10
15
20
25
30
35
40
45
50
1-D
ec
2-D
ec
3-D
ec
4-D
ec
5-D
ec
6-D
ec
7-D
ec
8-D
ec
9-D
ec
10-D
ec
11-D
ec
12-D
ec
13-D
ec
14-D
ec
15-D
ec
16-D
ec
17-D
ec
18-D
ec
19-D
ec
20-D
ec
21-D
ec
22-D
ec
23-D
ec
24-D
ec
25-D
ec
26-D
ec
27-D
ec
28-D
ec
29-D
ec
30-D
ec
31-D
ec
NO
(kg/
hour
)
Date
East Stack West Stack
-
EASTLINK VENTILATION STACK EMISSION MONITORING REPORT: OCTOBER -
DECEMBER 2011
January 2012 Report No. 097613024-020-R-Rev0 29
8.2.4.2 Nitrogen Dioxide Nitrogen dioxide (1-hour average) mass
rate of emission statistics for the reporting period are given in
Table 24. A plot of nitrogen dioxide (1-hour average) mass rate of
emission for the reporting period is presented in Figure 18.
Table 24: Nitrogen Dioxide Mass Rate Percentiles (1 Hour
Average)
Station Nitrogen Dioxide Mass Rate (kg/h) (1-Hour Average)
Maximum 99th 98th 95th 90th 75th 50th
Eastern 0.7 0.5 0.5 0.4 0.4 0.3 0.1
Western 0.5 0.3 0.3 0.2 0.2 0.2 0.1
Figure 18: Nitrogen Dioxide Mass Rate (1 Hour Average)
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
1-D
ec
2-D
ec
3-D
ec
4-D
ec
5-D
ec
6-D
ec
7-D
ec
8-D
ec
9-D
ec
10-D
ec
11-D
ec
12-D
ec
13-D
ec
14-D
ec
15-D
ec
16-D
ec
17-D
ec
18-D
ec
19-D
ec
20-D
ec
21-D
ec
22-D
ec
23-D
ec
24-D
ec
25-D
ec
26-D
ec
27-D
ec
28-D
ec
29-D
ec
30-D
ec
31-D
ec
NO
2(k
g/ho
ur)
Date
East Stack West Stack Limit
-
EASTLINK VENTILATION STACK EMISSION MONITORING REPORT: OCTOBER -
DECEMBER 2011
January 2012 Report No. 097613024-020-R-Rev0 30
8.2.5 Stack Velocity The stack velocity (1 hour average) plot
for the reporting period is presented in Figure 19.
Figure 19: Stack Velocity (1 Hour Average)
0
2
4
6
8
10
12
14
16
18
20
1-D
ec
2-D
ec
3-D
ec
4-D
ec
5-D
ec
6-D
ec
7-D
ec
8-D
ec
9-D
ec
10-D
ec
11-D
ec
12-D
ec
13-D
ec
14-D
ec
15-D
ec
16-D
ec
17-D
ec
18-D
ec
19-D
ec
20-D
ec
21-D
ec
22-D
ec
23-D
ec
24-D
ec
25-D
ec
26-D
ec
27-D
ec
28-D
ec
29-D
ec
30-D
ec
31-D
ec
Vel
ocity
(m/s
)
Date
East Stack West Stack
-
EASTLINK VENTILATION STACK EMISSION MONITORING REPORT: OCTOBER -
DECEMBER 2011
January 2012 Report No. 097613024-020-R-Rev0 31
8.3 Data Validation and Exceptions Data contained in the report
has been validated against performance and calibration requirements
for each instrument. Data during maintenance and calibration
periods has been removed from the validated data sets. Tables 25
and 26 list the data exceptions for the eastern and western
ventilation stacks respectively. Data during automatic calibrations
of the gaseous atmospheric contaminants has also been removed from
the data sets.
Table 25: Data Exceptions - Eastern Ventilation Stack: December
2011 Start End Parameter Reason
2/12/2011 13:30 2/12/2011 13:40 NO, NO2, NOx
Maintenance/calibration
2/12/2011 13:30 2/12/2011 13:35 CO Maintenance/calibration
7/12/2011 0:40 8/12/2011 23:55 NO, NO2, NOx Invalid data - Span
drift
13/12/2011 10:15 13/12/2011 11:25 NO, NO2, NOx
Maintenance/calibration
13/12/2011 10:15 13/12/2011 11:25 CO Maintenance/calibration
13/12/2011 12:45 13/12/2011 13:55 PM2.5
Maintenance/calibration
13/12/2011 13:30 13/12/2011 14:50 PM10
Maintenance/calibration
19/12/2011 14:50 19/12/2011 21:25 CO Maintenance/calibration
24/12/2011 22:25 24/12/2011 22:50 PM2.5 Invalid data1
25/12/2011 22:30 25/12/2011 22:40 PM2.5 Invalid data1
27/12/2011 3:05 27/12/2011 3:40 PM2.5 Invalid data1
27/12/2011 20:55 27/12/2011 21:30 PM2.5 Invalid data1
28/12/2011 20:35 28/12/2011 21:00 PM2.5 Invalid data1
28/12/2011 22:40 28/12/2011 23:20 PM2.5 Invalid data1
29/12/2011 3:05 29/12/2011 3:40 PM2.5 Invalid data1
29/12/2011 8:40 29/12/2011 8:55 PM2.5 Invalid data1
30/12/2011 00:00 30/12/2011 16:00 NO, NO2, NOx Invalid data -
Span drift
Note: 1 - In the opinion of the reviewer.
Table 26: Data Exceptions - Western Ventilation Stack: December
2011 Start End Parameter Reason
2/12/2011 15:15 2/12/2011 15:40 NO, NO2, NOx
Maintenance/calibration
15/12/2011 0:40 20/12/2011 10:10 NO, NO2, NOx Invalid data -
Span drift
21/12/2011 10:20 21/12/2011 12:20 NO, NO2, NOx
Maintenance/calibration
2/12/2011 13:10 2/12/2011 14:00 CO Maintenance/calibration
2/12/2011 15:05 2/12/2011 15:15 CO Maintenance/calibration
12/12/2011 8:20 12/12/2011 8:40 CO Maintenance/calibration
19/12/2011 11:50 19/12/2011 13:05 CO Maintenance/calibration
19/12/2011 11:35 19/12/2011 13:05 PM2.5
Maintenance/calibration
19/12/2011 12:15 19/12/2011 13:25 PM10
Maintenance/calibration
23/12/2011 17:00 23/12/2011 23:55 PM10 Invalid data1
31/12/2011 16:25 31/12/2011 23:00 PM10 Invalid data1
19/12/2011 10:55 20/12/2011 6:25 Velocity Data logger error
Note: 1 - In the opinion of the reviewer.
-
EASTLINK VENTILATION STACK EMISSION MONITORING REPORT: OCTOBER -
DECEMBER 2011
January 2012 Report No. 097613024-020-R-Rev0 32
9.0 DISCUSSION
9.1 Comparison with Licence Limits EastLink emissions to air
from the road tunnel ventilation stacks DP1 and DP2 are subject to
the licence requirements contained in Environment Protection
Authority (Victoria) Waste Discharge Licence No. EA 63607.
The maximum measured 1 hour average mass rate for each parameter
is compared with the applicable licence limit in Table 27.
Table 27: Maximum (1 Hour Average) Mass Rate (01/10/2011 -
31/12/2011) Discharge Point No. Discharge Description Compound Mass
Rate (kg/h) Licence Limit (kg/h)
1 Western ventilation stack PM2.5 0.34 2.4
PM10 0.94 2.6
NO2 0.49 3.98
CO 29 112
2 Eastern ventilation stack PM2.5 0.37 2.4
PM10 0.88 2.6
NO2 0.69 3.98
CO 32 112
There were no exceedences of the licence limits for DP1 and DP2
during the reporting period.
Data capture statistics for 2011 year to date (01/01/2011 –
31/12/2011) are presented in Table 28.
Table 28: Data Capture Year to Date (%)
Station NO2 CO PM2.5 PM10 Velocity
Eastern 93.0 97.2 97.8 98.2 99.9
Western 90.1 96.2 98.9 99.1 99.2
-
EASTLINK VENTILATION STACK EMISSION MONITORING REPORT: OCTOBER -
DECEMBER 2011
January 2012 Report No. 097613024-020-R-Rev0
Report Signature Page
Mark Tulau Frank Fleer Senior Air Quality Specialist
Principal
MT/FF/SLH
A.B.N. 64 006 107 857 Golder, Golder Associates and the GA globe
design are trademarks of Golder Associates Corporation.
j:\env\2009\097613024 - eastlink
stack\correspondence\correspondence
out\097613024-020-r-rev0-transfield services.docx
- End of Report -
-
Golder Associates Pty Ltd Building 7, Botanicca Corporate Park,
570 – 588 Swan Street Richmond Victoria 3121 Australia T: +61 3
8862 3500