Top Banner
Replacing a Congenitally Missing Lateral Incisor using the Skinny 2.4 The case is a 23 year old petite female .
31

Replacing a Congenitally Missing Lateral Incisor using the Skinny 2.4 The case is a 23 year old petite female.

Dec 15, 2015

Download

Documents

Jaquan Mays
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Replacing a Congenitally Missing Lateral Incisor using the Skinny 2.4 The case is a 23 year old petite female.

Replacing a Congenitally Missing Lateral Incisor using the Skinny 2.4

The case is a 23 year old petite female .

Page 2: Replacing a Congenitally Missing Lateral Incisor using the Skinny 2.4 The case is a 23 year old petite female.

The patient was congenitally missing the maxillary left lateral incisor. Not the diminutive bone volume.

Page 3: Replacing a Congenitally Missing Lateral Incisor using the Skinny 2.4 The case is a 23 year old petite female.

Preoperative panoramic radiograph of the edentulous space.

Page 4: Replacing a Congenitally Missing Lateral Incisor using the Skinny 2.4 The case is a 23 year old petite female.

Because of the diminutive bone volume and palpable undercuts, a minimal flap was reflected to directly visualize the labial and palatal osseous contours.

Page 5: Replacing a Congenitally Missing Lateral Incisor using the Skinny 2.4 The case is a 23 year old petite female.

The first step in the drilling sequence is the Locator Drill.

Page 6: Replacing a Congenitally Missing Lateral Incisor using the Skinny 2.4 The case is a 23 year old petite female.

The Locator Drill is has a maximum cutting diameter of 1.8mm with the depth marking at 8mm.

Page 7: Replacing a Congenitally Missing Lateral Incisor using the Skinny 2.4 The case is a 23 year old petite female.

The Locator is important in a skilled implant placement because it establishes the center of the osteotomy which places the implant. It also begins the trajectory of the osteotomy.

Page 8: Replacing a Congenitally Missing Lateral Incisor using the Skinny 2.4 The case is a 23 year old petite female.

The Final Sizing Drill for the Skinny 2.4 System is sized for the length of implant selected. It has a 2.4mm diameter cutting diameter and a built in countersink. This offers safety and efficiency during the surgical phase.

Page 9: Replacing a Congenitally Missing Lateral Incisor using the Skinny 2.4 The case is a 23 year old petite female.

The osteotomy is completed.

Page 10: Replacing a Congenitally Missing Lateral Incisor using the Skinny 2.4 The case is a 23 year old petite female.

Notice the countersink in the osteotomy that is matched in diameter and depth to the implant.

Page 11: Replacing a Congenitally Missing Lateral Incisor using the Skinny 2.4 The case is a 23 year old petite female.

The Skinny 2.4 is delivered to the osteotomy via the vial cap driver system. This is a true premounted delivery system that permits seamless insertion of the implant from the sterile vial to the osteotomy.

Page 12: Replacing a Congenitally Missing Lateral Incisor using the Skinny 2.4 The case is a 23 year old petite female.

The implant is threaded digitally with the vial cap as far as the practitioner desires. Depending on the density of the bone, the implant can be threaded as much or as little as is comfortable.

Page 13: Replacing a Congenitally Missing Lateral Incisor using the Skinny 2.4 The case is a 23 year old petite female.

The vial cap is removed from the driver exposing the 4mm square drive male end. Several instruments can be utilized to thread the implant in to full depth. A ratchet wrench, a straight driver, or an internal 2mm hex within the access opening of the driver can be used.

Page 14: Replacing a Congenitally Missing Lateral Incisor using the Skinny 2.4 The case is a 23 year old petite female.

The implant is threaded digitally with the vial cap as far as the practitioner desires. Depending on the density of the bone, the implant can be threaded as much or as little as is comfortable.

Page 15: Replacing a Congenitally Missing Lateral Incisor using the Skinny 2.4 The case is a 23 year old petite female.

Notice the final threaded depth of the implant corresponds to the depth of the Final Sizing Drill.

Page 16: Replacing a Congenitally Missing Lateral Incisor using the Skinny 2.4 The case is a 23 year old petite female.

Notice the final threaded depth of the implant corresponds to the depth of the Final Sizing Drill.

The horizontal line indicator on the Final Sizing Drill exactly places the coronal aspect of the implant with predictability, efficiency and safety.

Page 17: Replacing a Congenitally Missing Lateral Incisor using the Skinny 2.4 The case is a 23 year old petite female.

When the green driver is removed, the precision of the osteotomy and the important crestal ridge relative to the coronal aspect of the implant is apparent.

Page 18: Replacing a Congenitally Missing Lateral Incisor using the Skinny 2.4 The case is a 23 year old petite female.

The first stage surgical cover screw is threaded into the Skinny via its premounted .050” (1.25mm) hex driver.

Page 19: Replacing a Congenitally Missing Lateral Incisor using the Skinny 2.4 The case is a 23 year old petite female.

Sutures are placed for closure.

Page 20: Replacing a Congenitally Missing Lateral Incisor using the Skinny 2.4 The case is a 23 year old petite female.

Sutures are placed for closure.

Page 21: Replacing a Congenitally Missing Lateral Incisor using the Skinny 2.4 The case is a 23 year old petite female.

Panoramic radiograph after the surgical phase.

Page 22: Replacing a Congenitally Missing Lateral Incisor using the Skinny 2.4 The case is a 23 year old petite female.

After three months has passed, the implant is exposed and the first stage surgical cover screw is replaced with a tissue healing abutment and the site is allowed to heal.

Page 23: Replacing a Congenitally Missing Lateral Incisor using the Skinny 2.4 The case is a 23 year old petite female.

The green driver that was used at the time of surgery is used again as an impression coping to create an implant level master model.

Page 24: Replacing a Congenitally Missing Lateral Incisor using the Skinny 2.4 The case is a 23 year old petite female.

The green driver is seated and positively mated to the implant and secured via a .050” (1.25mm) hex drive fixation screw. The driver is the same one used at surgery to deliver and thread the first stage surgical cover screw to the implant.

Page 25: Replacing a Congenitally Missing Lateral Incisor using the Skinny 2.4 The case is a 23 year old petite female.

The vial cap driver is removed and the case is ready for conventional crown and bridge impression techniques. Notice that the flat of the green driver is facing facially to make it easier to re-insert it into the impression.

Page 26: Replacing a Congenitally Missing Lateral Incisor using the Skinny 2.4 The case is a 23 year old petite female.

Crown and bridge impression techniques and materials employed. If the impression coping had interfered with the bite, the impression would be taken and the bite would be confirmed after the impression coping was removed.

Page 27: Replacing a Congenitally Missing Lateral Incisor using the Skinny 2.4 The case is a 23 year old petite female.

Whatever technique and material is employed is acceptable. This impression will not require the accuracy of the final impression. This impression is to customize an abutment.

Page 28: Replacing a Congenitally Missing Lateral Incisor using the Skinny 2.4 The case is a 23 year old petite female.

In this case, the impression coping did not interfere with the bite, so the impression captured the impression coping, the counter arch and the bite.

Page 29: Replacing a Congenitally Missing Lateral Incisor using the Skinny 2.4 The case is a 23 year old petite female.

In this case, the impression coping did not interfere with the bite, so the impression captured the impression coping, the counter arch and the bite.

Page 30: Replacing a Congenitally Missing Lateral Incisor using the Skinny 2.4 The case is a 23 year old petite female.

A custom milled Cement On Abutment was threaded to full seat on the implant and a conventional crown and bridge impression was taken to construct the final crown.

Page 31: Replacing a Congenitally Missing Lateral Incisor using the Skinny 2.4 The case is a 23 year old petite female.

The final crown was delivered.