OWNER: STATE OF MISSOURI MICHAEL L. PARSON, GOVERNOR DEPARTMENT OF CORRECTIONS DESIGNER: SIMON OSWALD ARCHITECTURE 2801 WOODARD DRIVE, SUITE 103 COLUMBIA, MO 65202 SHEET NUMBER: PROJECT MANAGEMENT: OFFICE OF ADMINISTRATION DIVISION OF FACILITIES MANAGEMENT, DESIGN AND CONSTRUCTION G001 1 OF 5 SHEETS JULY 26, 2019 C1915-01 PROJECT NUMBER: SITE NUMBER: ASSET NUMBER: 7013 9327013002 REPLACE ROOF CREMER THERAPEUTIC COMMUNITY CENTER FULTON, MISSOURI
5
Embed
REPLACE ROOF CREMER THERAPEUTIC COMMUNITY CENTER … · william h. oswald -architect license no. a-5419 replace roof cremer therapeutic community center fulton, missouri project #
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
OWNER: STATE OF MISSOURI MICHAEL L. PARSON, GOVERNOR
DEPARTMENT OF
CORRECTIONS
DESIGNER: SIMON OSWALD ARCHITECTURE
2801 WOODARD DRIVE, SUITE 103
COLUMBIA, MO 65202
SHEET NUMBER:
PROJECT
MANAGEMENT:OFFICE OF ADMINISTRATION
DIVISION OF FACILITIES
MANAGEMENT, DESIGN AND
CONSTRUCTION
G0011 OF 5 SHEETS
JULY 26, 2019
C1915-01PROJECT NUMBER: SITE NUMBER: ASSET NUMBER:
7013 9327013002
REPLACE ROOFCREMER THERAPEUTIC COMMUNITY CENTER
FULTON, MISSOURI
DRIVE
CLINIC
SOUTH
STATE HIGHWAY "0"
STAFF CIRCLE
HIL
LC
RE
ST
ST
RE
ET
WAREHOUSE DRIVE
HADLEY DRIVE
5TH
CIRCLE
STREET
5T
HC
IRC
LE
ST
RE
ET
NORTHDRIVE
CLINIC
O.T. DRIV
E
ELECTRICALSUBSTATION
ST
AT
E S
T.
CREMER COMMUNITY THERAPUTIC CENTER
CONTRACTOR STAGING & PARKING
BUILDING CODE: 2018 IBCUSE GROUP: I-3,FULLY SPINKLERED
CONSTRUCTION TYPE: IB
CODE INFORMATION
GENERAL NOTES & SYMBOLS
011/8" = 1'-0"A201 A501
VIEW NAME
ASI02
X1STRUCTURAL GRID
LEVEL MARKER
SPOT ELEVATION
100'-0"
BUILDING SECTION
WALL SECTION
DETAIL SECTION
A5011
1A301
INTERIOR ELEVATION
BUILDING ELEVATION
WALL TAG
DOOR TAGNEW WORK KEYNOTE
DEMOLITION KEYNOTE
REVISION TAGTRUE NORTH ARROW
REFERENCING SHEET
DRAWING SHEET
OCCUPANT LOAD
100
A0000
C
01
A2
1
A101
SIM
1
A101
SIM
1
A101
SIM
NameElevation
MAIN ROOF: 12,233 SFGENERATOR ROOF: 192 SFGYMNASIUM ROOF 2,764 SFDELIVERY LOBBY 305 SFADD ALT #1 ELEVATOR HOISTWAYS 223 SF
APPROXIMATE SQUARE FOOTAGES
TOTAL 15,717 SF
ISSUE DATE:
SHEET NUMBER:
CHECKED BY:DRAWN BY:
DESIGNED BY:
SHEET TITLE:
CAD DWG FILE:
STATE OF MISSOURI
MICHAEL L. PARSON,
GOVERNOR
OFFICE OF
ADMINISTRATION
DIVISION OF FACILITIES
MANAGEMENT,
DESIGN AND
CONSTRUCTION
KMT
WHO
SOA
Architecture
Interior Design
Planning
Sustainability
2801 Woodard Drive, Suite 103Columbia, MO 65202573.443.1407
www.soa-inc.com
Missouri Certificate of Authority Number: 000826
DEPARTMENT OF
CORRECTIONS
KMT
A101
STAGING &
LOCATION PLAN
ISSUE DATE: JULY 26, 2019
SHEET 2 OF 5
William H. Oswald - ArchitectLicense No. A-5419
REPLACE ROOF
CREMER THERAPEUTIC
COMMUNITY CENTER
FULTON, MISSOURI
PROJECT # C1915-01
689 E. 2ND STREET
FULTON, MO 65257
JULY 26, 2019
ISSUE FOR:CONSTRUCTION
DOCUMENTS
1" = 80'-0"A101
01 STAGING/LOCATION PLAN
FACILITY # 9327013002
SITE # 7013
F
I
ISSO
UR
OETA
ST
M
RE
GIS
TERED ARCH
ITE
CT
WILLIAM
HOWARDOSWALDNUMBER
A-5419
07/19/2019
GENERAL
G001 COVER SHEET
ARCHITECTURAL
A101 STAGING & LOCATION PLAN
A201 ROOF DEMOLITION PLAN
A202 ROOF PLAN
A203 CONSTRUCTION DETAILS
1/8" = 1'-0"
GENERAL SYMBOLS LEGEND
REVISION DATE
01
03
04
04 04
04
040404
0101
01
01
01
02 02
DEPTH: 2 5/8"
DEPTH: 7"
DEPTH: 2 1/2"
DEPTH: 7 1/4"
DEPTH: 7 1/4"
01
05
04
05 NOTE: EXISTING ROOF MADE UP OF TAPERED INSULATION BOARD ON EXPANDED POLYSTYRENE INSULATION. ALL FULLY ADHERED W/ ASPHALT ADHESIVE. THE DEPTHS INDICATE THE THICKNESS OF THE SYSTEM @ EACH CORE.
THE EXISTING CONCRETE DECK MAY BE SLOPING.
0606
04
07
07
07
07
07
0707
07
07
07
07
07
07
07
08
DEPTH: 6 1/4"
02
09
02
01
10
2"Ø3"Ø
2"Ø
4"Ø
2"Ø
4"Ø2"Ø
10
2"Ø
4"Ø1"Ø
10
4"Ø
4"Ø
4"Ø
1"Ø10
10
1"Ø
2"Ø
3"Ø
1"Ø
1"Ø
2"Ø
4"Ø
4"Ø
2"Ø
2"Ø
3"Ø
4"Ø
2"Ø
3"Ø
4"Ø4"Ø
11
4"Ø
8"Ø
6"Ø
GENERAL NOTES - DEMOLITION
1. REMOVE WALLS INDICATED BY THEFOLLOWING LINETYPE (UNLESSNOTED OTHERWISE):
EXISITING CONCRETE STRUCTURAL DECK
SEALANT INSTALLED B/W NEW COUNTERFLASHING & SALVAGED MECH, VENTS TO BE RESET
VENTS TO BE RESET
NEW BLOCKING TO RAISE CURB WHERE NECESSARY
WOOD FIBER CANT
EXIST. CURB STRUCTURE TO REMAIN, EXCEPT DISASSEMBLE AND REASSEMBLE AS NECESSARY TO INSTALL NEW ROOF
COVERBOARD ON TAPERED INSULATION ON FLAT INSULATION