Top Banner
RENT DIRECT ASIA Rent Direct Asia Registered Head Office: Rent Direct Asia (Thailand) Limited, 170/7 MOO 5, SAMNAKTHON BANCHANG, RAYONG 21130
17

Rent Direct Asia...• DNV 2.7.1 ATEX Workshop Containers (CE and ATEX certified) • DNV 2.7.1 Iron Containers • Data Acquisitions And Data Gathering For Pump Monitoring At The

Jul 24, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Rent Direct Asia...• DNV 2.7.1 ATEX Workshop Containers (CE and ATEX certified) • DNV 2.7.1 Iron Containers • Data Acquisitions And Data Gathering For Pump Monitoring At The

RENT DIRECT ASIA

Rent Direct Asia Registered Head Office:Rent Direct Asia (Thailand) Limited,170/7 MOO 5, SAMNAKTHONBANCHANG, RAYONG21130

Page 2: Rent Direct Asia...• DNV 2.7.1 ATEX Workshop Containers (CE and ATEX certified) • DNV 2.7.1 Iron Containers • Data Acquisitions And Data Gathering For Pump Monitoring At The

WHO WE ARE

We are an equipment rental provider based in South East Asia. With our main support facility in Thailand, and satellite support facilities strategically placed within Malaysia and Brunei. Rent Direct Asia aim’s to have support yards in Vietnam and Ranong by Q42020.

We offer over 40 years of collective oil industry management experience together with a wide range of high quality Zone ll and rig safe DNV certified equipment to the market with the customers needs in mind without compromising on safety or quality.

Our goal is to offer specialized equipment, direct to the end user and to be a cost effective provider of quality equipment packages.

Our equipment is designed to the leading international design codes whilst maintain an emphasis on SEA site specific limitations and location challenges.

Our main focus is to safely provide the highest quality, and a diverse range of rental equipment on the market to our customers.

We can design and fabricate a wide range of niche equipment suited to customer individual needs.

We can source equipment new or used for land or offshore operations that meet the individuals requirements.

We can offer a flexible business model including lease , lease to own through to outright purchase.

www.rentdirectasia.com

Rent Direct Asia

Page 3: Rent Direct Asia...• DNV 2.7.1 ATEX Workshop Containers (CE and ATEX certified) • DNV 2.7.1 Iron Containers • Data Acquisitions And Data Gathering For Pump Monitoring At The

ORGANIZATION CHARTRent Direct Asia

www.rentdirectasia.com

Group Director(s)

Group Accountant / Financial Controller

Country Specific Accounting

Group Operation Managment

Operations Coordinator and

Technical Support team

Maintenance and fabrication team

Group Business Development

Country Specific Business

Development (Future)

Group Administrator

Country Specific Administrator

Group Engineering

Page 4: Rent Direct Asia...• DNV 2.7.1 ATEX Workshop Containers (CE and ATEX certified) • DNV 2.7.1 Iron Containers • Data Acquisitions And Data Gathering For Pump Monitoring At The

RENTAL FLEET

• DNV 2.7.1 Zone 2 Air Compressors (CE certified ATEX 94/9/EC Zone 2 )

• DNV 2.7.1 Zone 2 Well Service Pumps (CE and ATEX 94/9/EC Zone 2 )

• DNV 2.7.1 Zone 2 Sea Water Injections Pumps (CE and ATEX 94/9/EC Zone 2 )

• DNV 2.7.1 Zone 2 Compliant Heat Exchangers (CE and ATEX 94/9/EC Zone 2 )

• DNV 2.7.1 Zone 2 Air After Coolers / Gas compression pre-coolers (CE and ATEX 94/9/EC Zone 2 )

• DNV 2.7.1 Zone 2 Hydraulic Power Packs (CE and ATEX 94/9/EC Zone 2 )

• DNV 2.7.1 Zone 2 Batch Mixers 50 bbl. / 100 bbl. (CE and ATEX 94/9/EC Zone 2 )

• DNV 2.7.1 Zone 2 Power Generation 30 Kva ~ 350 Kva (ATEX 94/9/EC Zone 2 )

• DNV 2.7.1 ATEX Zone 2 Mobile Spider Crane (CE and ATEX certified, basket only DNV certified)

• DNV 2.7.1 Air Dryer Packages (CE and ATEX certified)

• DNV 2.7.1 Rig Safe Air Compressors (CE and ATEX 94/9/EC Zone 2 )

• DNV 2.7.1 Bulk Storage/Mix Tanks• DNV 2.7.1 ATEX Workshop Containers (CE and ATEX certified)

• DNV 2.7.1 Iron Containers• Data Acquisitions And Data Gathering For Pump Monitoring At The Wellsite

Rent Direct Asia

www.rentdirectasia.com

Page 5: Rent Direct Asia...• DNV 2.7.1 ATEX Workshop Containers (CE and ATEX certified) • DNV 2.7.1 Iron Containers • Data Acquisitions And Data Gathering For Pump Monitoring At The

AIR COMPRESSOR FLEET

• Zone II 400CFM 125 psi• Zone ll 875CFM 150 psi• Zone ll 900CFM 200 psi• Zone ll 1,060CFM 125 psi• Rig Safe 1600CFM 150 psi• Rig Safe 1,300 CFM 150psi• Rig Safe 760 CFM 300psi

Features

• All containerized Heavy duty, fully bunded DNV2.7-1 offshore container • Designed for stacking in use - ISO Blocks for locked-on safety • Internal personnel access when stacked to eliminate external scaffolding

for space saving• Compact size transportable three units in a 40ft shipping container• All-pneumatic starting and shutdown systems • Flushable cleaning system for exhaust gas cooler • High capacity on-board fuel tanks • ATEX 94/9/EC Zone 2 hazardous area internal lighting

Access Hatches Top and bottom

Zone ll Engines

Rent Direct Asia

www.rentdirectasia.com

Page 6: Rent Direct Asia...• DNV 2.7.1 ATEX Workshop Containers (CE and ATEX certified) • DNV 2.7.1 Iron Containers • Data Acquisitions And Data Gathering For Pump Monitoring At The

ZONE II TRIPLEX PUMPING FLEET

• DNV 2 piece skid design Skid A fully containerized Skid B Open• Caterpillar 3306DITA 330hp engine and Allison HT754CR Transmission• National JWS 340 pump 10,000 PSI up to 8.7BBL/Min

JWS 340 Pump

• DNV 2 piece skid design Skid A fully containerized Skid B Open• Caterpillar 3306DITA 330hp engine and Allison HT754CR Transmission• National JWS 165 pump 5,000 PSI up to 7.7BBL/Min

JWS 165 Pump

WOMA 400 Pump • DNV fully containerized bunded skid • Caterpillar 3306DITA 330hp engine with WTD-11-340 PTO drive• WOMA ARP 400 pump 2,610 PSI and up to 5.3BBL/M

FMC M13 Pump • DNV 2 piece skid light weight open design Skid A /Skid B • JCB 444 engine 84.5 hp with PRM 750-4 transmission• FMC M1322 API pump 1,330 PSI and up to 2.9BBL/M

OFM 600 Pump • DNV 1 piece skid design hydraulically driven• OFM W600 pump max 16,000 PSI up to 16BBL/Min

Rent Direct Asia

www.rentdirectasia.com

UNION TX125 Pump • Working pressure 1,300 to 7,500psi (dependent on fluid end size)

• Flow rates 41 to 263 GAL/Min (dependent on fluid end size)

Page 7: Rent Direct Asia...• DNV 2.7.1 ATEX Workshop Containers (CE and ATEX certified) • DNV 2.7.1 Iron Containers • Data Acquisitions And Data Gathering For Pump Monitoring At The

AIR DRYERS, AFTERCOOLERS

• Installed in DNV 2.7.1 design offshore skid• Produced air -40 and air quality ISO 8573.1• Operating pressure to 45 bar• Flow 1,000cfm at 7 bar, 2,700cfm at 30 bar and 4,000cfm at 45bar• Filtration level 1 micron dust removal

SD100 HP45 Air Dryers

• Installed in DNV 2.7. design offshore skid• 1,800 CFM flow rate• 26 bar operating pressure• Suitable for Air or Gas cooling

ABAC 30HP After Coolers

Automatic Operating Panel Operating systems

System DesignRent Direct Asia

www.rentdirectasia.com

Page 8: Rent Direct Asia...• DNV 2.7.1 ATEX Workshop Containers (CE and ATEX certified) • DNV 2.7.1 Iron Containers • Data Acquisitions And Data Gathering For Pump Monitoring At The

ZONE II SPIDER CRANE

• The MC-104C-PN model Spider Crane is a mobile crane with a boom-type winch mounted on a rubber tracked undercarriage. It is capable of self-propelled travel and crane work.

• Designed to work in zone ll hazardous areas (Atex).• Hand Held L2 Ex Smart Load Measuring Device that records job information and programable alarm

parameter limits.• Ideal for well head maintenance or use remote areas with limited support.

1.85m Boom 3.00m Boom 4.15m Boom 5.30m Boom

Working

Radius

(m)

Total

Rated

Load (kg)

Working

Radius

(m)

Total

Rated

Load (kg)

Working

Radius

(m)

Total

Rated

Load (kg)

Working

Radius

(m)

Total

Rated

Load (kg)

<1.1 995 <1.1 995 <1.8 820 <2.4 650

1.3 980 1.3 980 2.0 750 2.5 620

1.5 890 1.5 890 2.5 620 2.8 550

1.65 790 2.0 750 2.8 550 3.0 500

2.5 620 3.0 500 3.5 380

2.8 550 3.5 380 4.0 300

3.95 300 4.5 250

5.1 200

Hand held remote load measuring devise

Rent Direct Asia

www.rentdirectasia.com

Page 9: Rent Direct Asia...• DNV 2.7.1 ATEX Workshop Containers (CE and ATEX certified) • DNV 2.7.1 Iron Containers • Data Acquisitions And Data Gathering For Pump Monitoring At The

STEAM HEAT EXCHANGER

• DNV 2.7.1 offshore skid design • 4.2 MMBtu 'sour gas' service Coil Design -20°C - +121°C • Steam Inlet / Condensate outlet 2" Hammer Unions Fig 206 • Inlet / Outlet Product 3" Hammer Unions Fig 1502 • Inlet / Outlet Valve Cameron 3.1/16” ,Rupture Disk and Safety Valves fitted• Service H2S NACE MR-01-75 fully automatic temperature control • Maximum Steam input 10barg @180degrees C• In line choke valve

10K Heat Exchangers

Rent Direct Asia

www.rentdirectasia.com

Page 10: Rent Direct Asia...• DNV 2.7.1 ATEX Workshop Containers (CE and ATEX certified) • DNV 2.7.1 Iron Containers • Data Acquisitions And Data Gathering For Pump Monitoring At The

CENTRIFUGAL PUMPS

• DNV 2.7.1 offshore skid design • Optional Electric or Diesel driven • Operating 3610/2953 ft. Head• 185 / 165 GPM • 4” suction/ 2.5” Discharge• Small ergonomic foot print BB3 split case pump• Limited stock in-country , also available through our affiliated

partner

Multi stage

Single Stage • DNV 2.7.1 offshore skid design • Max flow rates up to 2,140GPM • Operating pressure up to 268 PSI• 3 to 8” suction / 3 to 6” Discharge• DRY PRIME / Suction lift 25 foot

Rent Direct Asia

www.rentdirectasia.com

Submersible • Hydraulically driven • Max flow rates up to 1,260GPM • 125 ft of operating head• 6” suction and 6” Discharge

Page 11: Rent Direct Asia...• DNV 2.7.1 ATEX Workshop Containers (CE and ATEX certified) • DNV 2.7.1 Iron Containers • Data Acquisitions And Data Gathering For Pump Monitoring At The

INJECTION/PRESSURE PUMPS

• Milton Roy double diaphragm injection pumps • Electrically driven, IEC Ex Class 1 zone 2 IIC T3• Flow rates up to 6.6 gal/min • Operating pressure up to 1,150 PSI & 1/2” to 2 “ suction and

discharge

Chemical Injection Pumps

Pressure Test Pumps • Air driven packaged HP pumps suitable for pressure testing and well head valve controls

• Pressure Rating up to 10,000psi • Optional built in Chart recorder

Rent Direct Asia

www.rentdirectasia.com

Page 12: Rent Direct Asia...• DNV 2.7.1 ATEX Workshop Containers (CE and ATEX certified) • DNV 2.7.1 Iron Containers • Data Acquisitions And Data Gathering For Pump Monitoring At The

GENERATORS UNITS

• Zone II Atex certified• All containerized DNV2.7-1 • 30 to 350KVA • Flushable cleaning system for exhaust gas cooler • ATEX 94/9/EC Zone 2 hazardous area internal lighting

Zone II

Rent Direct Asia

www.rentdirectasia.com

Hydraulic driven • Hydraulically driven• 10 to 60 KVA• Packaged to suit requirements

Page 13: Rent Direct Asia...• DNV 2.7.1 ATEX Workshop Containers (CE and ATEX certified) • DNV 2.7.1 Iron Containers • Data Acquisitions And Data Gathering For Pump Monitoring At The

• DNV 2.7.1 Crash Frame• ASME VIII Div. 1 ANSI B31.3 NACE MR 01-75 • 150psi working pressure• Pressure rated sight glass and safety valves• 3” 150 inlet and outlet flanges

Surge Tank

Rent Direct Asia

www.rentdirectasia.com

Mud Tanks • DNV 2.7.1 crash Frame • 100 to 200 bbl capacity• 4” suction and roll lines

Tote Tanks • DNV 2.7.1 crash Frame • 500 to 1,000 gal

TANKS – PUMP SUPPORT

Page 14: Rent Direct Asia...• DNV 2.7.1 ATEX Workshop Containers (CE and ATEX certified) • DNV 2.7.1 Iron Containers • Data Acquisitions And Data Gathering For Pump Monitoring At The

BASKETS AND CONTAINERS

• DNV 2.7.1 Container fully bunded and Stackable• ATEX 94/9/EC Zone 2 hazardous area internal lighting• 3.85m x 2.25m x 2.21m• Gross weight 10,000KG• Work bench, Vice and storage shelves

Workshop Containers

Iron Transport Containers • DNV 2.7.1 Container fully bunded and Stackable• ATEX 94/9/EC Zone 2 hazardous area internal lighting• 3.85m x 2.25m x 2.21m• Gross weight 10,000KG• Capacity of 400ft 2 inch Iron package

Transport Baskets • DNV 2.7.1 certified• Various configurations and weights

Rent Direct Asia

www.rentdirectasia.com

Page 15: Rent Direct Asia...• DNV 2.7.1 ATEX Workshop Containers (CE and ATEX certified) • DNV 2.7.1 Iron Containers • Data Acquisitions And Data Gathering For Pump Monitoring At The

• All containerized Heavy duty, fully bunded DNV2.7-1 offshore container • Zone II • Flushable cleaning system for exhaust gas cooler • High capacity on-board fuel tanks • ATEX 94/9/EC Zone 2 hazardous area internal lighting• 3,000 PSI operating pressure• Pump 1 = 94 gal/min – Pump 2 = 72 gal/min• Pilot pump 13 gals/min

Caterpillar 330HP

Rent Direct Asia

www.rentdirectasia.com

HYDRAULIC POWER PACKS

Page 16: Rent Direct Asia...• DNV 2.7.1 ATEX Workshop Containers (CE and ATEX certified) • DNV 2.7.1 Iron Containers • Data Acquisitions And Data Gathering For Pump Monitoring At The

• DNV Zone II 2 & 3 Piece modular 50/100bbl batch mixers • Utility multi function service packages ( air compressor and Generator) • Ultra light weight Injection pumps up to 64gpm @ 3,000PSI • Ultra light weight 200CFM Air compressors• Ultra light weight 400CFM driven Air compressors• DNV Zone II Light weight 30 kva generators• DNV Zone II Light weight 60 kva generators• Rent Direct Asia has the capabilities to package Niche project specific and bespoke packages

Rent Direct Asia

www.rentdirectasia.com

Enquiries welcome on our conceptual designs

DESIGN AND PLANNING

Page 17: Rent Direct Asia...• DNV 2.7.1 ATEX Workshop Containers (CE and ATEX certified) • DNV 2.7.1 Iron Containers • Data Acquisitions And Data Gathering For Pump Monitoring At The

[email protected]

Rent Direct Asia

www.rentdirectasia.com

Enquires to