YAZHEN QIN, MS China Associate Professor, Peking University People’s Hospital, Peking University Institute of Hematology Dr. Qin specializes in the molecular diagnostics in hematologic malignancies. Her field of research focuses on mechanism of leukemogenesis.
19
Embed
Relapsed Chronic Myeloid Leukemia: new players in targeted therapy
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
YAZHEN QIN, MS
China Associate Professor, Peking University People’s
Hospital, Peking University Institute of Hematology
Dr. Qin specializes in the molecular diagnostics in
hematologic malignancies. Her field of research
focuses on mechanism of leukemogenesis.
“China Standardization Project of BCR-ABL
detection in CML”
——an efficient way for multi-centers to
simultaneously derive and validate CFs
Ya-Zhen Qin
Peking University People's Hospital,
Peking University Institute of Hematology,
Beijing, China
Standardization of BCR-ABL detection in CML
BCR-ABL transcript levels detected by real-time PCR
(RQ-PCR)reflect molecular response to TKI for CML
patients
Variation exists among the individual laboratory’s
report, which limits its clinical application
BCR-ABLIS
Proposed in October 2005
Harmonizing the differing methodologies for measuring
BCR-ABL transcripts
using an individual laboratory’s conversion factor (CF)
to express BCR-ABL transcript levels on an
internationally agreed scale
MMR: BCR-ABLIS=0.1%
Blood 2006; 108: 28-37
Acquisition of CF
——sample exchange with reference lab
Derivation of CF
Validation of CF
Great variation existed in the BCR-ABL
results from different laboratories in China
Four samples (same BCR-ABL levels prepared in TRIzolby one lab)
Detected in 10 labs in China, May 2010
Variation caused by:
different protocols
problems in protocol
0.01
0.1
1
10
100
1000
0
sample 1BC
R/A
BL
tra
nscri
pt
levels
(%
)
0.01
0.1
1
10
100
sample 2BC
R/A
BL
tra
nscri
pt
levels
(%
)
0 0.001
0.01
0.1
1
10
sample 3BC
R/A
BL
tra
nscri
pt
levels
(%
)
0 0.00001
0.0001
0.001
0.01
0.1
1
0
sample 4BC
R/A
BL
tra
nscri
pt
levels
(%
)
“China Standardization Project of RQ-
PCR detected BCR-ABL in CML”
Initiated in 2010
Aim
To test the accuracy and stability of BCR-ABL
detection of the participated laboratories and
help to improve the performance of those
laboratories not well done
To derive and validate laboratory specific CFs
of the participants to make the results from
different laboratories comparable
Participants of Project
A regional reference laboratory:
Peking University People’s Hospital, Peking
University Institute of Hematology (PUIH)
3 batches of laboratories :
36 laboratories from hospitals and
commercial organizations
Summary of the five comparisons of the 1st batch
laboratories
0.000001
0.00001
0.0001
0.001
0.01
0.1
1
10
1:1000 1:100 1:10 1
样本稀释度
BC
R-A
BL
/AB
L
0.00001
0.0001
0.001
0.01
0.1
1
1:3000 1:300 1:30 1:3
样本稀释度B
CR
-AB
L/A
BL
0.00001
0.0001
0.001
0.01
0.1
1
1:400 1:40 1:4
样本稀释度
BC
R-A
BL
/AB
L
0.0001
0.001
0.01
0.1
1
1:1000 1:100 1:10 1
样本稀释度
BC
R-A
BL
/AB
L
0.0001
0.001
0.01
0.1
1
1:1000 1:100 1:10 1
样本细胞稀释度
BC
R-A
BL
/AB
LSamples May 2010 Samples August 2010 Samples April 2011
Samples July 2011 Samples September 2012
Accuracy of
BCR-ABL
detection by RQ-
PCR is greatly
improved
Acquisition of
CF
Qin, YZ. et al. Chinese J of Hematology 34: 104-108 (2013)
A sample exchange between Adelaide international
reference laboratory (IMVS) and PKUPH in 2012
PUIH: regional reference lab
Distributing samples for calculating CF
Preparing and distributing samples by PUIH
Performing BCR-ABL detection according to the laboratory’s
own protocols
Analyzing results and calculating CF by PUIH
Usual method of validation in the world
Participating laboratory sends 20-30 samples to reference laboratory, they simultaneously test these samples and CF is validated
Validation is a heavy work for a reference laboratory
we used a simultaneously distributing
same prepared samples method to
perform validation
Validating CF in China
Preparing validation samples by PUIH
20~30 times of dilution of fresh BCR-ABL (+) nucleated
cells by BCR-ABL (-) cells.
The dilutions covered 3-log BCR-ABL levels range, with
the highest level lower than 10%IS
Each set contained 21 samples with different BCR-ABL