Top Banner
Climalife – Dehon Group Catalogue 1.0 Refrigeration . Air conditioning . Heating . Renewable Energy
11

Refrigeration . Air conditioning . Heating . Renewable Energyclimalife.dehon.ro/uploads/assets/Galco/Catalogue... · Air conditioning . Heating . Renewable Energy. ... Semi-hermetic

May 12, 2018

Download

Documents

duongque
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Refrigeration . Air conditioning . Heating . Renewable Energyclimalife.dehon.ro/uploads/assets/Galco/Catalogue... · Air conditioning . Heating . Renewable Energy. ... Semi-hermetic

Clim

alife

– D

eh

on

Gro

up

C

ata

log

ue

1.0

Refrigeration . Air conditioning . Heating . Renewable Energy

Page 2: Refrigeration . Air conditioning . Heating . Renewable Energyclimalife.dehon.ro/uploads/assets/Galco/Catalogue... · Air conditioning . Heating . Renewable Energy. ... Semi-hermetic

A KEY PARTNER FOR ENERGY PERFORMANCE

Dehon Group Quality, Safety andEnvironment Policy

Listen & Satisfy:our customers by paying attention to their needs and continuously improving our products and services.

By conductingcustomer satisfaction surveys and formalising customer visits with visit reports. By developingthe services we provide to suit the needs of our customers, in areas such as traceability of products and packaging.By improvingcommunication between the different companies in the Group.

Anticipate Risks & Ensure:the safety of our colleagues, our partners, and our customers and aim for zero accidents.

By complying with rules and regulations.By implementing preventive measures at work stations and backing up with safety training.By advising our clients/partners about the correct use of our products, in order to guarantee their safety.

Control & Reduce:the environmental impact of our products and activities.

By developing Greenway products with reduced environmental impact.By reducing and recovering waste.By controlling our greenhouse gas emissions.

We are committed to putting at your disposal the resources necessary for the implementation of these objectives and we ask all of our colleagues to take an active part in their deployment throughout all areas of the business.

Pierre-Etienne DehonChairman

Developing innovative, sustainable solutions forclimate control systems

For more than a century, Climalife has been Europe’s specialist in cooling fluids for refrigeration and air conditioning.

Its dynamism and commitment to quality and protecting the environment has also enabled it to gain cutting-edge expertise in the heating and renewable energy markets.

More than 250 employees are available to share their knowledge on diverse sectors as: industrial markets, commercial markets (large outlets, local stores, etc.), housing and apartments, and the service sector (offices, hospitals, airports…).

They can meet your needs with a range of products and services suitable for anyclimate control system: refrigerants, secondary refrigerants/heat transfer fluids, lubricants, equipment, cleaning, brazing alloys, analysis, services.

Climalife benefits from the structure of the Dehon Group, a key player in performance chemistry, in developing innovative solutions and building special partnerships with professionals, particularly producers, manufacturers, industrial firms, and distributors.

Innovative services developed for safety and the environment, regular technical and regulatory information, and high-performance tools complete this comprehensive plan.

Climalife offers its products and services worldwide, thanks to a global distribution network made up of 13 subsidiaries (Germany, Belgium, Netherlands, France, United Kingdom, Spain, Hungary, Switzerland, Scandinavia, Italy, Russia, Panama, and Romania), and local representatives (India, China, Singapore and Malaysia) and an export subsidiary, Climalife Galco, for the rest of the world.

Page 3: Refrigeration . Air conditioning . Heating . Renewable Energyclimalife.dehon.ro/uploads/assets/Galco/Catalogue... · Air conditioning . Heating . Renewable Energy. ... Semi-hermetic

Climaliferecommandations

0%

20%

40%

R-404A R-407A R-507A

60%

80%

100%

110%

90%

70%

50%

30%

10%

Energy consumption at compressor Ef�ciencyCooling capacity

0%

20%

40%

R-407C R-407E R-410A

60%

80%

100%

120%

140%

160%

Energy consumption at compressor Ef�ciencyCooling capacitySolutions for replacing R-22

For each application, replacement fluids are possible for direct expansion installations.A preliminary comprehensive study of all parameters, checking the general condition of the installation, its economic viabilityand the oil to use, is essential before any fluid change over.

Replacement refrigerants for R-22:

• Air-conditioning application:R-407C, R-407E*, R-410A**.

• Refrigeration application:R-404A, R-407A, R-507A.

*R-407E can be used with high ambient temperatures

**Please note! In the case of using R-410A, this equipment is designed for R-410A and not for retrofitting R-22

0%

20%

40%

R-404A R-422A R-422D R-417A R-427A R-407A Performax LT

60%

80%

100%

110%

90%

70%

50%

30%

10%

Cooling capacity LT

Min. 90% production of R-404A

Min. 40% GWP reduction

GWP ReductionCooling capacity MT

Solutions for replacing R-404AAs per the European regulations, now a low GWP fluid is available to replace R-404A.

Selection criteria: - Cooling capacity at medium or low temperature: 90% minimum compared to R-404A- GWP reduced by at least 40% compared to R-404A (GWP = 3922).

HFO: molecules on the market (*)Current HFC HFO

Non flammableHFO Low flammability (ASHRAE A2L)

Application examples

R-134aGWP = 1430

SolsticeTM yf GWP = 4

Automotive AC, Vending Machines, Refrigerators

R-1234ze GWP = 6

Chillers, CO2 Cascade,Refrigerators

R-123GWP = 77

R-1233zd GWP = 5

Centrifugal chillers

HFO: 4th generation fluids for future installations

(*) Mixes are currently in development phase. Climalife will accompany you and present these new solutions to you.

-30/40°C regime SC = 20k SR = 5k - Semi-hermetic reciprocating compressor

-5/40°C regime SC = 5k SR = 5k - Semi-hermetic reciprocating compressor

Climatisation - Comparatif au R-22Air-conditioning – compared to R-22

Refrigeration – compared to R-22

4 5

Page 4: Refrigeration . Air conditioning . Heating . Renewable Energyclimalife.dehon.ro/uploads/assets/Galco/Catalogue... · Air conditioning . Heating . Renewable Energy. ... Semi-hermetic

HFO (HydroFluoro-Olefins)are 4th generation refrigerants. They are an alternative with low GWP values that reduce environmental impact while offering energy efficiency.

HC (Hydrocarbons)R-290 and R-600a are hydrocarbons that are classified as flammable, used. See the specifications to check the conditions of their use in refrigeration systems.

PFC (Perfluorocarbons)Refrigerant for ultra low temperature.

HCFC (Hydrochlrofluorocarbons):It is commonly used as a propellantand refrigerant. These applications are in process of being phased out due to the compound’s ozone depletion potential (ODP) and high global warming potential (GWP).

HFC (Hydrofluorocarbons): Refrigerants in this group not contributeto the destruction the ozone layer. HFC refrigerants were designed to replace HCFCs.

RefrigerantsRefrigerant gases intended for refrigeration and air conditioning

We offer a full range of refrigerants that can be applied in different sectors. These refrigerants are available in innovative packaging and varying in sizes. The packagings are either in refillable cylinders or in disposables.

HFO

Ammonia

HC

PFC

Product Packaging Charge

Product Packaging Charge

Product Packaging Charge

Product Packaging Charge

R-1234ze Disposable 13,6 kg

Solstice® yf Cylinder 6 L 5 kgSolstice® yf Cylinder 12,3 L 10 kg

Propan R-290 Cylinder 1 L 390 g

Isobutane R-600a Cylinder 1 L 420 gIsobutane R-600a Disposable 6,5 kg

R-116 HP Cylinder 52,15 kg

R-14 HP Cylinder 8 kgR-14 HP Cylinder 30 kg

Ammonia Cylinder 88 L 45 kgAmmonia Drum 930 L 480 kg

HCFC

HFC

Product Packaging Charge

Product Packaging Charge

R-123 Drum 50 kg

R-141b Disposable 13,6 kg

R-22 Disposable 13,6 kgR-22 Disposable 22,7 kgR-22 Ton drum 940 kgR-22 Isotank 20 T

R-406A Disposable 13,6 kg

R-408A Disposable 10,9 kg

R-409A Disposable 13,6 kg

R-134a Can 340 g to 1 kgR-134a Disposable 13,6 kgR-134a Disposable 22,7 kgR-134a Ton drum 940 kgR-134a Isotank 20 T

R-23 HP Cylinder 12 L 9 kg

R-32 Cylinder 12 L 10 kgR-32 Ton drum 720 kg

R-404A Disposable 10,9 kgR-404A Ton drum = 750 kgR-404A Isotank = 18 T

R-407A Disposable 11,3 kg

R-407C Disposable 11,3 kgR-407C Ton drum 850 kg

R-407E Disposable 11,3 kg

R-407F Disposable 11,3 kg

R-410A Disposable 11,3 kgR-410A Container 740 kgR-410A Isotank 18 T

R-427A Disposable 11,3 kg

R-507A Disposable 11,3 kgR-507A Ton drum 700 kgR-507A Isotank 17,5 T

R-508B HP Cylinder 12 L 9 kg

CFC banned HCFC HFC – NH3

R-12 R-406A R-134a

R-409A R-437A

R-22 Air conditioning application

R-134a / R-407C

R-407A / R-407F / R-407E

R-410A / R-417A

R-422D / R-427A

R-22 Refrigeration application

R-134a

R-404A / R-507A

R-407A / R-407F

R-422D / R-427A

NH3

R-114 R-124 R-227ea / R-236fa / R-245fa

R-502 R-408A R-404A / R-507A / R-422A / R-407A / R-407F

R-13R-503

R-23R-508B

Possible replacement refrigerant according to applications

6 7

Page 5: Refrigeration . Air conditioning . Heating . Renewable Energyclimalife.dehon.ro/uploads/assets/Galco/Catalogue... · Air conditioning . Heating . Renewable Energy. ... Semi-hermetic

What is Frio +?Frio + is a trademark of the Climalife Company. Under this brand we deliver high quality Refrigerants. All Refrigerants are tested before each shipment in our “Climalife” Laboratory. This ensures that the chemical composition of the gas in the packaging is fully consistent with the Specification. High quality refrigerant Frio + is most appreciated and demanded product by our customers worldwide.

• Bar handle type.• One time filling valve.• Valve with Climalife logo hence quality approved.• Good and strong quality 3 layers carton.• Palletizing while packaging to ensure safe transport.• Valve laminated with plastic cover / valve rotated with a torque as per Climalife SOP.• Every disposable has hologram with unique number to track.• Container covered with bubble sheet from inside to prevent moisture

• As per government regulations, it is illegal to refill a disposable.• As a standard practice, It is highly risky to reuse the valve and disposable cylinder.• Always store refrigerant cylinders in dry area.• Do not store in direct sun light (temperature exceeding 52 Degree C / 125 Degree F).• Please check the standard of packaging and quality of product before using.

Logistic & Supply Chain SupportWe select for you the best possible prices, products, services and these negotiations are supported by a professional team of local and international staff on site.

• Product specifications are guaranteed, cargo inspection and certifications are available • Offering you the best possible incoterms• Short lead time and best possible delivery terms • Warranties benefit on our high end goods • Strong Trademarks with respect for copyrights and existing patents

We offer branded products for an exclusive overseas network of distributors so we can  differentiate us from competing products that you possibly can find on the local market.

RefrigerantsRefrigerant gases intended for refrigeration and air conditioning

Units R-22 R-134a R-23 R-32 R-404A R-407A R-407C R-407E R-407FComposition CHF2Cl CH2F-CF3 CHF3 44% R-125,

52% R-143a, 4% R-134a

20% R-32,40% R-12540% R-134a

23% R-32, 25% R-125, 52% R-134a

25% R-32, 15% R-125, 60% R-134a

23% R-32, 25% R-125, 52% R-134a

Boiling point (under 1,013 bar) °C -40,81 -26,08 -82 - 51,65 -46,57 -45,01 -43,81 -42.66 -46,06Temperature glide under 1,013 bar K 0 0 0 0 0,75 6,41 7 7.17 6,4Density of liquid at 25°C kg/m3 1194,6 1206,71 680,09 961 1044 1145 1137,5 1132 1116,9Density of saturating vapour at normal boiling point

kg/m3 4,82 5,257 4,662 2,987 5,48 4,881 4,63 4.48 4,46

Saturation pressure (Liquid sat.)25°C bar 10,44 6,654 49,986 16,9 12,55 12,53 11,9 11.49 13,1150°C 19,43 13,18 31,4 23,11 23,24 22,16 21.45 24,31Critical temperature °C 96,15 101,06 26,14 78,11 72,05 82,26 86,03 88.46 82,66Critical pressure bar absolute 49,9 40,59 48,32 57,82 37,29 45,15 46,29 47.02 47,55Critical density kg/m3 523,8 511,9 526,5 424 486,54 499 484,2 474 477,34Latent vapourisation heat at normal boiling point kJ/kg 233,7 216,97 239,4 381 200,94 235,57 249,8 257.85 257,21Specific heat at 25°CLiquid kJ/(kg.K) 0,08365 1,425 18,87 0,135 1,542 1,52 1,535 1.546 1,575Vapor under 1,013 bar 0,01058 0,8512 0,737 0,0124 0,877 0,829 0,837 0.843 0,834Cp/Cv ratio at 25°C under 1,013 bar 1,185 1,119 1,201 1,252 1,118 1,138 1,144 1.148 1,152NF-EN 378 classification L1 L1 L1 A2 L1 L1 L1 L1 L1ODP (R11 = 1) 0,055 0 0 0 0 0 0 0 0GWP (CO2 = 1) 1810 1430 14800 675 3922 2107 1774 1552 1824

Units R-410A R-427A R-507A R-508B R-1234ze Solstice® yf R-290 R-600aComposition 50% R-32,

50% R-125 50% R-134a, 25% R-125, 15% R-32, 10% R-143a

50% R-125, 50% R-143a

46% R-23, 54% R-116

CF3- CH = CHF CH2 = CFCF3 PropaneC3H8

IsobutaneC4H10

Boiling point (under 1,013 bar) °C -51,6 -46,55 -46,75 -87.6 -18,96 -29,49 -42,22 -11,7Temperature glide under 1,013 bar K 0,08 6,75 0 0,44 0 0 0 0Density of liquid at 25°C kg/m3 1058,6 1124,98 1047,9 Not applicable 1163 1092 580 550,65Density of saturating vapour at normal boiling point

kg/m3 4,173 4,78 5,585 6.548 5,71 5,98 2,417 2,826

Saturation pressure (Liquid sat.)25°C bar 16,57 11,43 12,83 Not applicable 4,99 6,83 2,03 0,5850°C 30,71 21,25 23,61 9,97 13,02 - -Critical temperature °C 71,35 85,32 70,62 11,2 109,37 94,7 96,7 134,98Critical pressure bar absolute 49 43,91 37,05 37,72 36,36 33,82 42,4 37,2Critical density kg/m3 459,53 689,97 490,77 568 489,24 475,55 220,48 225,5Latent vapourisation heat at normal boiling point kJ/kg 272,97 236,52 196,94 165.36 195,43 180,25 366,70Specific heat at 25°CLiquid kJ/(kg.K) 7,708 1,517 1,539 Not applicable 1,383 1,392 1,64 2,38Vapor under 1,013 bar 0,823 0,847 0,87 0.757 0,887 0,905 - -Cp/Cv ratio at 25°C under 1,013 bar 1,176 1,131 1,117 1.136 1,102 1,099 1,1364 1,0958NF-EN 378 classification L1 L1 L1 L1 L2L L2L A3 A3ODP (R11 = 1) 0 0 0 0 0 0 0 0GWP (CO2 = 1) 2088 2138 3985 13396 6 4 3 3

HCFC / HFC: physico-chemical properties* HFC / HFO / HC: physico-chemical properties*

*All elements are simulated using Refprop 8 and 9 and given purely as an indication. *All elements are simulated using Refprop 8 and 9 and given purely as an indication.

8 9

Page 6: Refrigeration . Air conditioning . Heating . Renewable Energyclimalife.dehon.ro/uploads/assets/Galco/Catalogue... · Air conditioning . Heating . Renewable Energy. ... Semi-hermetic

Climaliferecommandations

TEMPER® GREENWAY® NEO NEUTRAGEL® NEO FRIOGEL® NEOTHERMERA® R /THERMERA® AC

NEUTRAGUARD® NEO SOLUFLUID® GREENWAY® NEO HEAT PUMP GREENWAY® NEO SOLAR

Typical applications

Low temperature refrigeration and freezing, eg supermarkets, ice rinks, ski slopes, boats.

Commercial and industrial refrigeration installations, air-conditioning, food industry.

Industrial refrigeration and air conditioning systems.

Food industry and heat pumps.

Thermera® R : Food industry and commercial refrigeration industries.Thermera® AC : Heating, ventilation and air conditioning systems.

Water-based central heating circuits.Underfloor heating and cooling systems.Geothermal systems.

Solar thermal systems, heat pumps and traditional heating systems.

Ground source and air source heat pumps.

Solar thermal systems.

BasePotassium acetate and potassium formate

Bio PDO MEG MPG Betaine MPG MPG Bio PDO Bio PDO

Availability options

Ready To Use. Concentrate and Ready To Use.

Concentrate and Ready To Use.

Concentrate and Ready To Use.

Ready To Use. Concentrate. Ready To Use.Concentrate upon demand.

Ready To Use.Concentrate upon demand.

Ready To Use.Concentrate upon demand.

Key features

- Good biodegradability. - Low viscosity. - Long life organic inhibitors.

- Lower charge loss than glycol-based products.

- For use at low temperature.

- Long life organic inhibitors.

- Viscosity <MPG at low temperatures.

- Exchange surface <MPG.

- Pump size <MPG based.

- Embittering agent to avoid ingestion.

- Long life organic inhibitors.

- Viscosity <MPG. - Exchange surface <MPG.

- Pump size <MPG based.

- Long life organic inhibitors.

- Quantity in circulation <MEG.

- Excellent hard water stability.

- Safe all purpose fluid.

- Based on a sugar beet derivative.

- Traditional inhibitors. - Viscosity <MPG.

- Long life organic inhibitors. - Excellent hard water stability.

- Long life organic corrosion inhibitors.

- Formulae developed for ready to use specific applications.

- Long life organic corrosion inhibitors.

- Formulae developed for ready to use specific applications.

- Long life organic corrosion inhibitors.

- Formulae developed for ready to use specific applications.

Approvals

- Authorised by the French Health Ministry**.

- Approved by Belgaqua.

- Authorised by the French Health Ministry**.

- Approved by Belgaqua.

- Authorised by the French Health Ministry**.

- Approved by Belgaqua.

- Authorised by the French Health Ministry**.

- Authorised by the French Health Ministry**.

- Approved by Belgaqua.

- Authorised by the French Health Ministry**.

- Approved by Belgaqua.

Working temperature

range-50°C to +70°C -50°C to +200°C -33°C to +180°C -28°C to +150°C -20°C to +65°C -28°C to +180°C -20°C to +200°C -20°C to +200°C -25°C to +200°C

Freezing point -55°C -55°C* -37°C* -32°C* -35°C / -15°C -32°C -25°C -25°C -30°C / -25°C

Please ask for a copy of our individual product data sheets for more information on each of our products.

* Where the heat transfer fluid is sold in a form that needs to be diluted, the freezing point shown refers to a dilution of 50%, except for the Greenway® Neo where the freezing point is shown to a concentration of 70%.** As a heat transfer fluid for use in single exchange hot sanitary water treatment.

Heat Transfer Fluids by Climalife

10 11

Page 7: Refrigeration . Air conditioning . Heating . Renewable Energyclimalife.dehon.ro/uploads/assets/Galco/Catalogue... · Air conditioning . Heating . Renewable Energy. ... Semi-hermetic

Products designed for heating and air conditioning installations as well as for new renewable energy technologies such as solar panels and geothermal systems.

Borax now has a “toxic” label, cat. 2 R60/61 as per the 30th ATP. A substance containing 8,5 % or more Borax must bear a toxicity label. The product has been added to the SVHC list (Substance of very high concern).

Secondary refrigerant fluidsProducts designed for industrial and commercial refrigeration purposes

Heat transfer fluidFluids dedicated to heat transfer

Neutraguard® Neo: Concentrated MPG. To be diluted. Used for central heating circuits. Formula approved by numerous hot static and dynamic tests. After dilution, Neutraguard® Neo makes it possible to obtain excellentprotection from freezing and strengthened protection from corrosion. It is recommended to use at least 33% concentration v/v of Neutraguard® Neo in order to ensure optimal anti-corrosion protection.

Neutraguard® Neo To be diluted Can 20 L / Drum 210 LNeutraguard® Neo To be diluted Container 1000 kg

Solufluid®: MPG. Ready-to-use formula for use specifically in sprinkler installations, underfloor heating/cooling and refrigeration or heat-transfer circuits.

Solufluid® - 25°C Can 20 LSolufluid® - 25°C Drum 210 L

Greenway® Neo Solar: Ready-to-use Bio PDOTM (1,3-propanediol) based fluid for thermal solar systems (flat or tubular sensors in vacuum). Effectively protects the metals present in the circuit from freezing and corrosion. Very low degradability: at 150°C for 150 hours, it degrades 3 times slower than MPG (at equivalent dilution) allowing a long lifespan.

Greenway® Neo Solar - 25°C Can 20 L / Drum 210 LGreenway® Neo Solar - 25°C Container 1000 kgGreenway® Neo Solar - 30°C Can 20 L / Drum 210 L

Please contact us for the concentrated product.

Greenway® Neo Heat Pump: Ready-to-use Bio PDOTM (1,3-propanediol) based fluid, for sensor circuits in geothermal or aerothermal applications. Biodegradable, this fluid limits floor pollution in the event of leakage in buried collectors. Effectively protects the circuits and floors from freezing.

Greenway® Neo Heat Pump - 25°C Can 20 L / Drum 210 L Greenway® Neo Heat Pump - 25°C Container 1000 kg

Please contact us for the concentrated product.

Greenway® Neo: Ready-to-use Bio PDOTM (1,3-propanediol) based fluid for sprinkler installations, underfloor heating/cooling and refrigeration or heat-transfer circuits and air-conditioning systems.

Greenway® Neo - 18°C Can 20 L / Drum 210 LGreenway® Neo - 18°C Container 1000 kgGreenway® Neo - 25°C Can 20 L / Drum 210 LGreenway® Neo - 25°C Container 1000 kg

Please contact us for other dilutions or the concentrated product.

Thermera® AC Betaine: Ready-to-use in air conditioning systems. Non-toxic, water and betaine based. Suitable for a very wide range of applications, and especially suited to those sectors where health and environmental issues are of particular importance.

Thermera® AC - 15°C Can 20 LThermera® AC - 15°C Drum 210 L

Glycol and dilutions

Products Freezing point Packaging

Friogel® Neo: Monopropylene glycol based product with organic corrosion inhibitors for low temperature refrigera-tion installations. Formulation approved by the French General Health Department as a heat transfer fluid for single exchange sanitary water production systems. When diluted in water, Friogel® Neo provides excellent protection against frost and corrosion of the metals present in the installation (Regulation DGS/SD7A N°490 of 25/11/2009). It is recommended to use at least 33% concentration v/v of Friogel® Neo in order to ensure optimum anti-corrosion protection. The inhibitors incorporated into Friogel® Neo provide excellent protection against limescale, rust and oxidants for the metals present in the installation.

• Concentrated MPGFriogel® Neo To be diluted Can 20 L / Drum 210 LFriogel® Neo To be diluted Container 1000 kg

• Ready to use MPG Friogel® Neo - 20°C 38% Drum 210 LFriogel® Neo - 20°C 38% Container 1000 kg

Please contact us for others dilutions or for bulk conditionning.

Neutragel® Neo: Monoethylene glycol based product with organic corrosion inhibitors for low temperature industrial refrigeration installations (with embittering agent). The extent to which it should be diluted in demineralised water depends on the protection temperature required. It is recommended to use at least a 33% concentration v/v of Neutra-gel® Neo in order to ensure optimum anti-corrosion protection. The inhibitors which have been incorporated into Neu-tragel® Neo provide excellent protection against limescale, rust and oxidants for the metals present in the installation.

• Concentrated MEG Neutragel® Neo To be diluted Can 20 L / Drum 210 LNeutragel® Neo To be diluted Container 1000 kg

• Ready to use MEGNeutragel® Neo - 20°C 35% Drum 210 lNeutragel® Neo - 20°C 35% Container 1000 kg

Please contact us for others dilutions or for bulk conditionning.

Thermera® R: Betaine based product supplied ready to use in refrigeration installations. Non-toxic and environmen-tally friendly. Suitable for a wide range of applications, especially in those sectors where health and environmental considerations are of particular importance.

Thermera® R - 35°C Can 20 L / Drum 210 LThermera® R - 35°C Container 1000 L

Greenway® Neo: 1,3-propanediol (Bio PDOTM) based product and organic corrosion inhibitors for refrigeration. 1,3 Propanediol, comes from renewable plant-based materials, and has the advantage of a lower viscosity than Mono-Propylene Glycol which is conventionally used as this type of fluid. Once diluted with water, Greenway® Neo provides excellent protection against freezing and gives enhanced protection against the corrosion of metals in va-rious circuits of different designs (steel, aluminium, copper, brass, solder, etc.). Greenway® Neo is authorised by the French health administration as a heat transfer fluid for thermal processing in simple exchange systems for sanitary water production up to a maximum concentration of 70% of the volume.

Concentrated Bio PDOTM

Greenway® Neo To be diluted Can 20 L / Drum 210 LGreenway® Neo To be diluted Container 1000 kg

• Ready to use Bio PDOTM

Greenway® Neo - 30°C Can 20 L / Drum 210 LGreenway® Neo - 30°C Container 1000 kgGreenway® Neo - 55°C Can 20 L / Drum 210 LGreenway® Neo - 55°C Container 1000 kg

Please contact us for others dilutions or for bulk conditionning.

Glycol and dilutions

Products Freezing point % Concentration volume Packaging

12 13

Page 8: Refrigeration . Air conditioning . Heating . Renewable Energyclimalife.dehon.ro/uploads/assets/Galco/Catalogue... · Air conditioning . Heating . Renewable Energy. ... Semi-hermetic

Lubrication is one of the most important factors in whether or not a refrigeration installation works correctly. The choice of lubricant is specific to the installation and applications in question. It is important to follow the recommendations of the compressor manufacturer. The oil ensures that the different moving parts of the compressor are lubricated by forming a lubricating, homogenous “film”. In rotary screw compressors, it also ensures tightness and therefore effective refrigeration. Choosing the right oil is essential if you want to ensure the performance and longevity of your refrigeration installation.

LubrificantsProducts intended for the lubrification of refrigeration compressors

Mineral oils Synthetic oils (continued)

Oil Analysis

Semi-synthetic oils

Synthetic oils

Wax-free hydrocarbon mixtures specifically chosen for their excellent fluidity at low temperatures. Oils adapted for use with CFC, HCFC and ammonia-based secondary refrigerant fluids.

CP-1009-68 HT / MIN 18,92 L / 208 L

Mobil Arctic 155 MIN 4 L / 20 L / 208 LMobil Arctic 300 MIN 20 L / 208 L

Suniso 3 GS MIN 4 L / 20 LSuniso 4 GS MIN 4 L / 20 LSuniso 5 GS MIN 4 L / 20 L

HQ MIN 46 MIN 4 L / 20 LHQ MIN 68 MIN 4 L / 20 L

• POE: polyol ester oils

These are for use with HFCs in all refrigeration and air conditioning applications (except for car A/C).

Bitzer BSE 32 POE 5 L / 10 LBitzer BSE 170 POE 10 L / 200 L

Bitzer B 150 SH POE 20 L

Bitzer BSE 60 K / 85 K POE 1 L / 5 L

CPI Solest 31HE POE 0,95 L / 3,78 L / 18,92 L / 208 LCPI Solest 22 POE 0,95 L / 3,78 LCPI Solest LT 32 POE 3,78 L /18,92 L / 208 LCPI Solest 46 POE 3,78 L /18,92 L / 208 L CPI Solest 68 POE 3,78 L /18,92 L / 208 L CPI Solest 120 POE 3,78 L /18,92 L / 208 LCPI Solest 170 POE 0,95 L / 3,78 L /18,92 L / 208 LCPI Solest 220 POE 18,92 LCPI Solest 370 POE 18,92 L / 208 L

CPI CP 4214-150 POE 18,92 L / 208 LCPI CP 4214-320 POE 18,92 L / 208 L

HQ POE 22 POE 1 L / 5 L / 20 LHQ POE 32 POE 1 L / 5 L / 20 LHQ POE 46 POE 1 L / 5 L / 20 LHQ POE 68 POE 1 L / 5 L / 20 LHQ POE 170 POE 5 L / 20 LHQ POE 220 POE 20 L

Mobil EAL Arctic 22 POE 5 LMobil EAL Arctic 22 CC POE 5 L / 20 LMobil EAL Arctic 32 / 46 / 68 POE 5 L / 20 LMobil EAL Arctic 100 POE 20 L / 208 LMobil EAL Arctic 220 POE 208 L

• PAG: poly alkylene glycolsThese are for use with R-134a in car airconditioning systems.

HQ PAG 46 PAG 250 mlHQ PAG 68 PAG 250 ml

• Acitest Unipro: On site acidity control test for an instantaneous result. Allows diagnosis during mainte-nance, increases the installation’s security and productivity and reduces the prospect of failure. Researched and developed by Climalife to determine the acidity level of an oil. Gives an indication of its state: good, limit, or acid.

Acitest Unipro Box of 6 Acidity test for all kinds of additivated or non additivated oils (formulation without toluene).

Mixtures of mineral and synthetic oils designed for refrigeration installations which work at low temperatu-res and use limited miscibility secondary refrigerant fluids with mineral oils such as R-22 fluid.

Bitzer B 5.2 AB / MIN 5 L

Polymers made up of specific chemical monomers such as esters. The first synthetic oils were developed for HCFCs (AB and PAO). With the arrival of HFCs came a new kind of oil (POE), since mineral oils are not miscible with HFCs.

• AB: alkyl benzene oilsThese are recommended for R-22 type fluids and HCFC mixtures. They are compatible with traditional mineral oils. Where the original oil is proved to be incompatible with mineral oils, alkylbenzene oils offer an excellent replacement.

Mobil Zerice S 32 AB 20 LMobil Zerice S 46 AB 20 L / 208 LMobil Zerice S 68 AB 20 LMobil Zerice S 100 AB 20 L / 208 L

Mobil Arctic SHC NH 68 AB / PAO 20 L

Shell S4-FR-V32 AB 20 LShell S4-FR-V68 AB 20 L

Zerol 150 AB 5 L / 20 L

• PAO: poly alfa olefin oilsThese have very low melting points and excellent thermic stability, which render them suitable for use in systems using R-22 or ammonia in extreme conditions.

CPI CP 4647-68 PAO / AB 18,92 L / 208 LCPI CP 4601-100 PAO 18,92 L / 208 LCPI CP 4600-46 PAO 18,92 L / 208 LCPI CP 4600-68 PAO 18,92 L / 208 LCPI CP 4600-100 PAO 18,92 L / 208 LCPI CP 4600-150 PAO 18,92 L / 208 LCPI CP 4624-68-F PAO 18,92 L / 208 LCPI CP 6006-68 PAO 18,92 L / 208 L

Mobil Arctitc SHC 226 E PAO 20 L / 208 LMobil Arctic SHC 228 PAO 20 LMobil Arctic SHC 230 PAO 20 LMobil Arctic SHC 234 PAO 208 L

Products Oil Type Packaging Products Oil Type Packaging

Product Packaging Comments

Products Oil Type Packaging

Products Oil Type Packaging

14 15

Page 9: Refrigeration . Air conditioning . Heating . Renewable Energyclimalife.dehon.ro/uploads/assets/Galco/Catalogue... · Air conditioning . Heating . Renewable Energy. ... Semi-hermetic

Why regularly clean and disinfect an installation?The regular cleaning of an installation:- improves its performance,- prevents contamination,- avoids offensive odours,- increases longevity.

External cleaning of thermal installations

• Universal cleanerFrionett® Power: : Alkaline and non-corrosive cleaning product used to eliminate grease and other contaminants, intended for professionnal cleaning of refrigeration and air-conditioning facilities (evaporators, condensers, batteries, ventilators and other surfaces).

Frionett® Power Ultra RTU Trigger spray bottle 750 ml Ready to use

Frionett® Power Ultra Concentrated can 5 L

• Cleaner, degreaser, disinfectant, deodorantFrionett® Activ’ One Shot: Disinfecting and deodorising product for the treatment of ventilation and air-conditioning systems (ducts,...) and for the purification of enclosed spaces. Eliminates bacterias, fungi and offensive odours.

Frionett® Activ’ One Shot Aerosol 150 ml

Frionett® Activ’ Foam: Powered active foam for cleaning small and medium sized refrigeration and air-conditioning installations (evaporators, internal units, etc...). Frionett Activ’ Foam cleans deeply, deodorises and prevents the development of micro-organisms.

Frionett® Activ’ Foam Foam aerosol 500 ml

Frionett® Activ’ RTU: Ready to use cleaning and disinfecting product for maintaining refrigeration and air-conditioning installations (for evaporators and internal units of small and medium capacities). Formulated to fight bacteria and fungi, Frionett® Activ’ RTU cleans deeply and eliminates offensive odours.

Frionett® Activ’ RTU Trigger spray bottle 750 ml

Frionett® Activ’: Concentrated cleaning and disinfecting product, designed to maintain refrigeration and air-conditioning installations (for large surface evaporators and internal units). Formulated to fight bacteria and fungi, Frionett Activ’ cleans deeply and eliminates offensive odours.

Frionett® Activ’ Concentrated can 5 L

• Cleaner degreaser and disinfectant dedicated for indirect food contact Frionett® Contact RTU: Ultra-powerful alkaline product for cleaning and disinfecting refrigeration systems (cold rooms, ...), and surfaces in food preparation areas (professional kitchens ...).

Frionett® Contact RTU Trigger spray bottle 750 ml Ready to useFrionett® Contact RTU Can 5 L Ready to use

Frionett® Contact Booster: Ultra-concentrated alkaline product for disinfecting and degreasing equipment, parts and surfaces of refrigerated installations, food preparation areas, professional kitchen, communities, etc.

Frionett® Contact Booster Flask 100 ml

Products Packaging

* Indirect food contact: Mandatory rinsing with water after use

With only 3 products, Frionett® Power, Frionett® Activ’, Frionett® Contact, the majority of your needs for cleaning, degreasing, disinfecting, preventing and deodorising are covered. They help you face every situation (air-conditioning, commercial refrigeration, industrial refrigeration, hospitals, professional kitchens, ...).

CleaningProducts for the cleaning and protection of refrigeration and air conditioning equipment

RTU Spray 750 ml

Concentrate d 5 l can

One Shot 150 ml

Foam Aerosol 500 ml

RTU Spray 750 ml

Concentrated 5 L can

RTU Spray 750 ml

RTU 5 lcan

Booster 100 ml

Condensers:

• small unit X • other XEvaporators:

• small unit X X X X • other X X XExternal parts of the unit XRefrigerated showcases X X X

Internal units:

• walls units X X • ceiling units X • ducts XExternal units X XEvaporators external lagging X XInternal lagging X XBatteries Air Handling units X

Ventilation systems XVentilation convectors XVentilation ducts XHeating systems X

Work surfaces X X XHoods X X XCooking equipement X X XRefrigerators / Freezers X X X

Flat surfaces (eg. floor…) X

REFRIGERATION

AIR CONDITIONING

HEATING - VENTILATION SYSTEMS

KITCHEN

OTHER APPLICATIONS

External cleaning of thermal installations

Frionett® POWERUniversal cleaner

Frionett® Contact cleaner disinfectant

indirect food contact*

Frionett® ACTIV’Cleaner disinfectant

1716

Page 10: Refrigeration . Air conditioning . Heating . Renewable Energyclimalife.dehon.ro/uploads/assets/Galco/Catalogue... · Air conditioning . Heating . Renewable Energy. ... Semi-hermetic

1418

ServicesComplete solutions for services and engineering

The Climalife approachGiven how diverse activities in the field are, customers find themselves needing to solve increasingly complexsituations.

The challenge is to achieve results and fulfil your obligations:• Complex configuration of installations (high volume, special fluids, etc.).• Need for special equipment (recovery unit, 70 bar pump, etc.) and occasional lack of available resources.• Difficult logistics and access.

Outsource your recovery services and benefit from these advantages

Turnkey solution for the service

Planning interventions across your country

Expertise in the physico-chemicalproperties of the liquids

Our experts will share their knowledge with your teams

Managing waste traceability (managing the BSD - Waste Tracking Form)

You can focus your efforts on your core business.

Benefit from our expertise in liquids and specialist equipment for efficient recovery.

You benefit from the knowledge and experience acquired by our chemical engineers.

You free yourself from operational and administra-tive constraints.

Waste

treatment

Site Audit

- Planning the work - Carrying out the service on

the system

integration

application

• Administrative and regulatory monitoring (traceability, BSD - Waste Tracking Form)• Collection (supplying packaging, logistical support)• Analysis (product identification carried out by our laboratories) • Reclamation (recycling or regeneration)• Destruction in accordance with the product type

• Product type and assessment of volumes• Site accessibility• Safety plan / risk analysis• Assistance in creating technical specifications documentation

Satisfaction

The Dehon Group is organized around three types of activity:

• Refrigeration, air-conditioning and heating - Climalife,

• Automotive after-market - SMB Auto,

• High-tech - Inventec.

And:

• Production & logistic entity of the Dehon Group - Crealis

In a continuous drive for improvement, Climalife retains the right to modify at all times the list of referenced products and to make alterations to any information in this document without warning. Moreover, the information contained in this catalogue is the result of our studies and our experience. It is provided in good faith, but should not, under any circumstances, be taken to constitute a guarantee on our part or an assumption of our responsibility. This is particularly the case when third party rights are at stake or in situations where a user of one of our products fails to observe applicable regulations. Lastly, the list of products in the catalogue is not exhaustive and we cannot guarantee on-shelf availability of all the referenced products.Non-contractual photo.  

Dehon Group – solutions to give you the lead

Page 11: Refrigeration . Air conditioning . Heating . Renewable Energyclimalife.dehon.ro/uploads/assets/Galco/Catalogue... · Air conditioning . Heating . Renewable Energy. ... Semi-hermetic

CAT

07/0

1.14

/V1/

IT -

310

259

205

RSC

Par

is - w

ww

.alte

rnac

tif.c

om -

Cré

dit p

hoto

s : I

tis, G

raph

icob

sess

ion,

ISto

ck, R

emy

Del

aclo

che,

EXX

ON

Mob

il, de

hon

serv

ice

BELGIUMdehon service belgiumAv. Carton de Wiart, 79B-1090 BRUSSELSTel.: 00 32 2 421 01 70Fax: 00 32 2 426 96 [email protected]

FRANCE (Head Office)dehon service SA26, avenue du Petit ParcF-94683 VINCENNES CedexTel.: 00 33 1 43 98 75 00Fax: 00 33 1 43 98 21 [email protected]

GERMANYDKF Dehon Kälte-Fachvertriebs GmbHRobert-Bosch-Strasse 14D-40668 MEERBUSCHTel.: 00 49 2150 7073 0Fax: 00 49 2150 7073 [email protected]

HUNGARYClimalife kftRét u.2.H-2040 BUDAÖRSTel.: 00 36 23 431 660 Fax: 00 36 23 431 [email protected]

ITALYClimalifeVia Pusterla n° 8I-20013 MAGENTA (MI)Tel.: 00 39 02 48401 206Fax: 00 39 02 48461 [email protected]

NETHERLANDSdehon service nederlandVan Konijnenburgweg 84NL-4612 PL BERGEN OP ZOOMTel.: 00 31 164 212 830Fax: 00 31 164 212 [email protected]

EXPORTGalco - ClimalifeAvenue Carton de Wiart, 79B-1090 BRUSSELS / BELGIUMTel.: 00 32 2 421 01 84Fax: 00 32 2 426 46 [email protected]

CHINAIPCT-Climalife中国上海市莘庄工业区元科路185号6号楼1-2楼 邮编2011081-2/F Building 6, No. 185 Yuanke Road,Xinzhuang Ind. Park, Shanghai, 201108,ChinaTel. : 0086-21-6442 3962*(extension 808)Fax : 0086-21-6442 3952

RUSSIAOOO Teknalys - ClimalifeProspect Mira 101, bat. 1, bureau 1212RU-129085 MOSCOWTel.: 00 7 (495) 410-3419Fax: 00 7 (499) 995-1215 [email protected]

ROMANIAClimalife kft Budapesta Sucursala Bucuresti RomaniaBulevardul Hristo Botev, Nr. 28Biroul nr. 4 Modulul I. Sectorul 3RO-BUCHARESTTel.: 00 40 76 11 49 [email protected]

SCANDINAVIAdehon nordic serviceÖstra Hamngatan 50B 3trSE-41109 GÖTEBORG Tél. /Fax: 00 46 44 21 58 [email protected]

SPAINfriogasPoligono Industrial SEPESParcela 10ES-46500 SAGUNTO (Valencia)Tel.: 00 34 9 6 266 36 32Fax: 00 34 9 6 266 50 [email protected]

SWITZERLANDProchimac SARue du Château 10CH-2000 NEUCHÂTEL Tel.: 00 41 32 727 3600Fax: 00 41 32 727 [email protected]

UNITED KINGDOMIDS Refrigeration LtdGreen CourtKings Weston LaneAvonmouthBRISTOL BS11 8AZ - UKTel.: 00 44 11 79 80 25 20Fax: 00 44 11 79 80 25 [email protected]