Model Applicable Tubing Specifications KDM20 KDM10 PAT.PEND Tubing O.D. No. of connecting tubes Model Weight (g) Color of release button ø3.2 ø4 ø6 ø4 ø6 ø8 ø8 ø3.2 10 20 Blue KDM10-23 KDM10-04 KDM10-06 KDM10-08 KDM20-23 KDM20-04 KDM20-06 KDM20-08 300 520 520 950 Tubing material Tubing O.D. FEP, PFA, Nylon, Soft nylon, Polyurethane ø3.2, ø4, ø6, ø8 Rectangular Multi-connector KDM Series No. of Connecting Tubes: 10, 20 Note) Please avoid using in a vacuum holding application such as a leak tester, since there is leakage. Be sure to read this before handling the products. Refer to back page 50 for Safety Instructions and pages 13 to 17 for Fittings and Tubing Precautions. Multi-connector is effective in saving labor for separate transportation of the panel and the machine, and for exchanging units due to failure. Substantial reduction in mounting space In comparison with a model requiring many union joints for panels and partitions, this model needs only a small space. One-touch connection/disconnection of connector Multiple pipes can be connected/disconnected in one-touch operation without connection er- ror. Thus man-hours for connection/dis-con- nection are cut down substantially. One-touch tube connection One-touch fittings substantially cuts down man-hours for piping. Made to Order (Refer to page 254 for details.) Plug case Irregular shape permits engagement in a proper position. With One-touch fitting Tubes of different sizes can be used simultaneously. Metric size: ø3.2, ø4, ø6, ø8 Applicable to non-copper type (electroless nickel plated) Two types, with 10 and 20 connector tubes, are available. Seal Possible to use from vacuum (–100 kPa) to 1 MPa. Clamp bolt Panel mounting bracket (Standard) Operation on the panel front permits mounting. Holes for mounting bolts are not necessary. (Mountable panel thickness is 5 mm maximum.) Plug connector Socket connector Plate Screw for bracket Type E retaining ring Socket case Air –100 kPa to 1 MPa 1.5 MPa –5 to 60°C (No freezing) Fluid Operating pressure range Note) Proof pressure Ambient and fluid temperature Caution RoHS With ø10, ø12 One-touch Fittings (P.256) With ø2 One-touch Fittings (P.254) 251 KQ2 KQB2 KS KX KM KF M H/DL L/LL KC KK KK130 DM KB KR KA KQG2 KG KFG2 MS KKA KP LQ MQR T IDK KDM
12
Embed
Rectangular Multi-connector KDM Series - SMC ETechcontent2.smcetech.com/pdf/KDM.pdf · 20 20 Mounting plate thickness 5 mm or less 2 x width across flats 4 Panel mounting hole Mounting
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Model
Applicable Tubing
Specifications
KDM20
KDM10
PAT.PEND
Tubing O.D.No. of connecting tubes Model Weight (g) Color of release buttonø3.2ø4 ø6
Note) Please avoid using in a vacuum holding application such as a leak tester, since there is leakage.
Be sure to read this before handling the products.Refer to back page 50 for Safety Instructions and pages 13 to 17 for Fittings and Tubing Precautions.
Multi-connector is effective in saving labor for separate transportation of the panel and the machine, and for exchanging units due to failure.
Substantial reduction in mounting spaceIn comparison with a model requiring many union joints for panels and partitions, this model needs only a small space.
One-touch connection/disconnection of connectorMultiple pipes can be connected/disconnected in one-touch operation without connection er-ror. Thus man-hours for connection/dis-con-nection are cut down substantially.
One-touch tube connectionOne-touch fittings substantially cuts down man-hours for piping.
Made to Order (Refer to page 254 for details.)
Plug caseIrregular shape permits engagement in a proper position.
With One-touch fittingTubes of different sizes can be used simultaneously.Metric size: ø3.2, ø4, ø6, ø8Applicable to non-copper type (electroless nickel plated)Two types, with 10 and 20 connector tubes, are available.
Seal
Possible to use from vacuum (–100 kPa) to 1 MPa.
Clamp bolt
Panel mounting bracket(Standard)
Operation on the panel front permits mounting. Holes for mounting bolts are not necessary. (Mountable panel thickness is 5 mm maximum.)
Plug connector
Socket connector
Plate
Screw for bracket
Type E retaining ring
Socket case
Air–100 kPa to 1 MPa
1.5 MPa–5 to 60°C (No freezing)
FluidOperating pressure range Note)
Proof pressureAmbient and fluid temperature
Caution
RoHS
With ø10, ø12 One-touch Fittings (P.256)With ø2 One-touch Fittings (P.254)
251
KQ2
KQB2KSKX
KM
KF
MH/DLL/LL
KC
KK
KK130
DM
KDM
KB
KR
KA
KQG2
KG
KFG2
MS
KKA
KP
LQ
MQR
T
IDK
KDM
Clamp bolt
Allen wrench (Nominal width across flats 4)
Irregular faces for engagement
Clamp bolt
Screw forbracket
Panel
Panel mountingbracket
Phillips screwdriver
Mounting
After loosening the screw, shift the bracket to the inside.
SeparationLoosen the clamp bolt to separate the plug side from the socket side.
ConnectionPut together the irregular faces for engage-ment and connect the plug case to the socket. After tightening the clamp bolt by hand, tighten it further with allen wrench (nominal width across flats: 4).
Panel mounting1. Loosen (4) screws for bracket on the
socket side using a Phillips screwdriver (JIS nominal No. 2) until the bracket touches the stop ring.
2. Shift the panel mounting bracket to the inside (Move the screw for bracket in the longitudinal direction of the slot) and put the connector in the panel mounting hole. (Panel-mounting hole: See Dimensions.)
Cross-recessed round head screw Plate Connector Case
Principal Parts Material
Model
Model
Plug case, Socket casePlate, Bracket
Plug connector, Socket connector
Clamp bolt, Screw for bracket,Cross-recessed head machine screw
Multi-connector is effective in saving labor for separate transportation of the panel and the machine, and for exchanging units due to failure.
Substantial reduction in mounting spaceIn comparison with a model requiring many union joints for panels and partitions, this model needs only a small space.
One-touch connection/disconnection of connectorMultiple pipes can be connected/disconnected in one-touch operation without connection error. Thus man-hours for connection/dis-connection are cut down substantially.
One-touch tube connectionOne-touch fittings substantially cuts down man-hours for piping.
Note) Please avoid using in a vacuum holding application such as a leak tester, since there is leakage.
Air–100 kPa to 1 MPa
1.5 MPa–5 to 60°C (No freezing)
FluidOperating pressure range Note)
Inch-size Rectangular Multi-connector
KDM SeriesNo. of Connecting Tubes: 10, 20
Proof pressureAmbient and fluid temperature
Plug caseIrregular shape permits engagement in a proper position.
With One-touch fittingTubes of different sizes can be used simultaneously.Inch size: ø ", ø ", ø ", ø "Applicable to non-copper type (Electroless nickel plated)Two types, with 10 and 20 connector tubes, are available.
SealPossible to use from vacuum to 1 MPa.
Clamp bolt
Panel mounting bracket(Standard)Operation on the panel front permits mounting. Holes for mounting bolts are not necessary. (Mountable panel thickness is 5 mm maximum.)
Plug connector
Socket connector
Plate
Screw for bracket
Type E retaining ring
Socket case
16
259
KQ2
KQB2KSKX
KM
KF
MH/DLL/LL
KC
KK
KK130
DM
KDM
KB
KR
KA
KQG2
KG
KFG2
MS
KKA
KP
LQ
MQR
T
IDK
KDM
Clamp bolt
Allen wrench (Nominal width across flats 4)
Irregular faces for engagement
Clamp bolt
Screw for bracket
Panel
Panel mountingbracket
Phillips screwdriver
Mounting
After loosening the screw, shift the bracket to the inside.
Shift the bolt to the outside and tighten it.
KDM Series
How to Use
Socket side
Plug side
10
KDM10P-01KDM10P-03KDM10P-07
KDM20P-09
RedKDM10P-09KDM20P-01
20KDM20P-03KDM20P-07
KDM10S-01KDM10S-03KDM10S-07
KDM20S-09
KDM10S-09KDM20S-01KDM20S-03KDM20S-07
KDMP-01KDMP-03KDMP-07
KDMS-09
RedKDMP-09KDMS-01KDMS-03KDMS-07
Cross-recessed round head screw
Plate Connector Case
Principal Parts Material
Model
Model
Plug case, Socket casePlate, Bracket
Plug connector, Socket connector
Clamp bolt, Screw for bracket,Cross-recessed head machine screw
Mixed Sizes of Plug Connectors and Socket Connectors
The rectangular multi-connector permits connector exchange in any desired position, thus allowing use of different sizes of tubes.
3. After shifting the bolt for bracket to the out-side, tighten the bolt by a Phillips screw-driver to fix the socket case.
4. Loosen the screw for bracket until the bracket touches the stop ring and shift the bracket to the inside to remove the con-nector from the panel.
1. Loosen the cross-recessed head machine screw by using a Phillips screwdriver to remove the plate from the case.
2. After exchanging connectors in desired places, fix the plate to the case by using a Phillips screwdriver.
TubingO.D.
No. of connection tubes Plug
Model Color ofrelease buttonSocket
TubingO.D.
Connector ModelColor of
release button
Plugconnector
Socketconnector(with seal)
CautionSeparationLoosen the clamp bolt to separate the plug side from the socket side.
ConnectionPut together the irregular faces for engage-ment and connect the plug case to the socket. After tightening the clamp bolt by hand, tighten it further with allen wrench (nominal width across flats: 4).
Panel mounting1. Loosen (4) screws for bracket on the
socket side using a Phillips screwdriver (JIS nominal No. 2) until the bracket touches the stop ring.
2. Shift the panel mounting bracket to the inside (Move the screw for bracket in the longitudinal direction of the slot) and put the connector in the panel mounting hole. (Panel-mounting hole: See Dimensions.)
260
20
20
Inch-size Rectangular Multi-connector KDM Series
KDM10
KDM20
Dimensions
( ): Dimensions for KDM10-09
( ): Dimensions for KDM20-09
Mou
ntin
g pl
ate
thic
knes
s5
mm
or l
ess
3 x width across flats 4Panel mounting hole
Handling of One-touch Fittings