Punctual Passive Active thermodynamics Active hidronic With dehumidification Commercial Ductworks HRV Heat Recovery Ventilation INNOVA s.r.l. Via I Maggio 8, 38089 Storo - TN, ITALY T. +39 0465 670104 E: [email protected]www.innovaenergie.com Edizione | Edition 2019 AMBIENT AIR INTAKE BUTLER The web is at service of your home The BUTLER web server is a new INNOVA system to manage an entire air conditioning system from a local and remote network. BUTLER is powerful, simple and economic at the same time; It consists of a Web Server card integrated in a micro computer, which allows to connect the heat pumps, ventilation systems and fancoils, equipped with electronic controls with Modbus port, to a normal wired or wireless LAN. There fore is possible to con gure an entire system or individual fancoils networks to control them from a smart phone, tablet or computer via local or remote connection; it is also possible to set for each one: a weekly calendar with time slots, create zones, operating scenarios such as house, school, hotel, and etc. All the functions are executable without installation of an additional software in directing to an IP address or via an free of charge APP. HRA DOMO HRA-I DOMO 08 14 20 H 30 H 80 140 200 300 0,96 1,64 2,69 3,57 0,62 1,02 1,44 2,16 10,7 / 4,1 9,6 / 3,9 11,7 / 4,0 9,9 / 3,9 38 41 39 43 TECHNICAL DATA u.m. Renewal air flow rate m3/h Heating power * kW Cooling power ** kW COP / EER Sound pressure at 3 m dB(A) ACCESSORIES HRA DOMO & HRA-I DOMO AUTOMATIC DIGITAL GRAPHIC REMOTE CONTROL (ONLY FOR HRA DOMO) V-TOUCH DIGITAL REMOTE CONTROL PANEL (ONLY FOR HRA DOMO) BUILT-IN BOX FOR REMOTE TOUCH CONTROL PANEL (JUST FOR HRA DOMO) ELECTRIC HEATING COIL AMBIENT TEMPERATURE SENSOR ACTIVE FILTER 2 SPARE FILTERS F7 BLACK OR WHITE WALL-MOUNTED SMART TOUCH ELECTRONIC CONTROL PANEL (ONLY FOR HRA DOMO) HRA-I DOMO Unit for air renewal in heat pump with active thermodynamic recovery and inverter combined with passive recovery HRA DOMO Active ventilation unit with recovery, integration, and recirculation free colling * External air -5 °C / Internal air 20 °C ** External air 35 °C / Internal air 27 °C TECHNICAL DATA u.m. Renewal air flow rate m3/h Recovery efficiency % Energy efficiency class Sound pressure at 3 m dB(A) Air flow rate in cycle m 3 /h HRW HRW X 30/15 H 50/25 H 60/15 H 90/25 H 30/15 V 50/25 V 60/15 V 90/25 V 30/15 HX 50/25 HX 60/15 HX 90/25 HX 30/15 VX 50/25 VX 60/15 VX 90/25 VX 154 265 155 263 161 258 160 261 162 282 154 270 163 264 163 264 85,7 86,0 86,6 86,5 83,9 86,0 84,0 85,9 75,3 74,0 75,4 74,1 75,2 75,0 75,2 75,0 B A B B B A B B B B C B B A B B 40,7 45,0 42,8 46,2 38,6 40,2 40,9 42,1 40,7 45,0 42,8 46,2 38,6 40,2 40,9 42,1 297 520 692 838 302 538 620 840 297 520 692 838 302 538 620 840 HRW Ventilation and air processing unit with the hidronic integration ACCESSORIES HRW E HRW X WALL-MOUNTED SMART TOUCH ELECTRONIC CONTROL PANEL WITH THERMOSTAT AND AMBIENT TEMPERATURE SENSOR WALL-MOUNTED SMART TOUCH ELECTRONIC CONTROL PANEL WITH THERMOSTAT AND AMBIENT TEMPERATURE SENSOR WITH INTEGRATED WIFI MODULE SONDA QUALITÀ ARIA HUMIDISTAT 2-WAY VALVE ON/OFF 3-WAY VALVE ON/OFF SUPPLY PLENUM FOR FLEXIBLE PIPES SUPPLY PLENUM FOR CORRUGATED PIPES ACTIVATED CARBON FILTER F7 SPARE FILTERS F7 HRW X Ventilation and air processing unit with the enthalpy heat exchanger free cooling SMART TOUCH control panel AMBIENT AIR EXHAUST EXPULSION EXTERNAL AIR AMBIENT AIR SUPPLY AIR RECIRCULATION EXPULSION AMBIENT AIR INTAKE EXTERNAL AIR AMBIENT AIR SUPPLY EXPULSION EXTERNAL AIR AMBIENT AIR INTAKE AIR RECIRCULATION weekly calendar with time bands Max 31 units HR Heat Recovery Ventilation Airleaf Vertical/horizontal fancoil Filomuro Wall fancoil Filoterra Trench fancoil ALL IN ONE Autonomously meets thermal, cooling and ventilation room requirements. INTEGRATED HYDRONIC COIL Integrated in the unit. COMBINED AIR SUPPLY The total air supply consists of fresh air and recirculated air. V E N T I L AT I O N Highly efficient brushless plug fans with low noise levels. Versions: - with integrated NODBUS - with integrated WIFI - in black or white Room control Local PC HELPS TO DEHUMIDIFY ROOMS IN THE SUMMER HIGHLY EFFICIENT SUMMER AND WINTER RECOVERY Thanks to the active thermodynamic recovery combined with passive recovery. HEATING AND COOLING Generates an initial power step in heating and cooling. DC INVERTER COMPRESSOR (HRA-I DOMO version)
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Punctual
Passive
Active thermodynamics
Active hidronic
With dehumidification
Commercial
Ductworks
HRVHeat
RecoveryVentilation
INNOVA s.r.l. Via I Maggio 8, 38089 Storo - TN, ITALY
BUTLERThe web is at service of your homeThe BUTLER web server is a new INNOVA system to manage an entire air conditioning system from a local and remote network. BUTLER is powerful, simple and economic at the same time; It consists of a Web Server card integrated in a micro computer, which allows to connect the heat pumps, ventilation systems and fancoils, equipped with electronic controls with Modbus port, to a normal wired or wireless LAN.
There fore is possible to con gure an entire system or individual fancoils networks to control them from a smart phone, tablet or computer via local or remote connection; it is also possible to set for each one: a weekly calendar with time slots, create zones, operating scenarios such as house, school, hotel, and etc. All the functions are executable without installation of an additional software in directing to an IP address or via an free of charge APP.
HRA DOMO HRA-I DOMO
08 14 20 H 30 H
80 140 200 300
0,96 1,64 2,69 3,57
0,62 1,02 1,44 2,16
10,7 / 4,1 9,6 / 3,9 11,7 / 4,0 9,9 / 3,9
38 41 39 43
TECHNICAL DATA u.m.
Renewal air flow rate m3/h
Heating power * kW
Cooling power ** kW
COP / EER
Sound pressure at 3 m dB(A)
ACCESSORIES HRA DOMO & HRA-I DOMO
AUTOMATIC DIGITAL GRAPHIC REMOTE CONTROL (ONLY FOR HRA DOMO)
V-TOUCH DIGITAL REMOTE CONTROL PANEL (ONLY FOR HRA DOMO)
BUILT-IN BOX FOR REMOTE TOUCH CONTROL PANEL (JUST FOR HRA DOMO)
ELECTRIC HEATING COIL
AMBIENT TEMPERATURE SENSOR
ACTIVE FILTER
2 SPARE FILTERS F7
BLACK OR WHITE WALL-MOUNTED SMART TOUCH ELECTRONIC CONTROL PANEL (ONLY FOR HRA DOMO)
HRA-I DOMOUnit for air renewal in heat pump
with active thermodynamic recovery and inverter combined
with passive recovery
HRA DOMO Active ventilation unit with recovery, integration, and
recirculation
free colling
* External air -5 °C / Internal air 20 °C ** External air 35 °C / Internal air 27 °C