Top Banner
Recent Advances in Microfluidic Device Applications for Environmental Monitoring and Toxicity Assessments Tae Hyun Yoon Laboratory of Nanoscale Characterization & Environmental Chemistry Department of Chemistry, Hanyang University, Seoul, 133-791, Korea
24

Recent Advances in Microfluidic Device Applications for ... · Applications for Environmental Monitoring and Toxicity Assessments ... (CE) well suited for ... Chem. (2009) Detection

Jul 05, 2018

Download

Documents

vannga
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Recent Advances in Microfluidic Device Applications for ... · Applications for Environmental Monitoring and Toxicity Assessments ... (CE) well suited for ... Chem. (2009) Detection

Recent Advances in Microfluidic Device

Applications for Environmental

Monitoring and Toxicity Assessments

Tae Hyun Yoon

Laboratory of Nanoscale Characterization & Environmental Chemistry

Department of Chemistry, Hanyang University,

Seoul, 133-791, Korea

Page 2: Recent Advances in Microfluidic Device Applications for ... · Applications for Environmental Monitoring and Toxicity Assessments ... (CE) well suited for ... Chem. (2009) Detection

What is Microfluidics ?

Advantages of Microfluidics

Key Components of Microfluidics

Application of Microfluidics for Environmental Monitoring

Application of Microfluidics for Toxicity Assessments

Other Potential “Benefits” of Microfluidics

Summary

Page 3: Recent Advances in Microfluidic Device Applications for ... · Applications for Environmental Monitoring and Toxicity Assessments ... (CE) well suited for ... Chem. (2009) Detection

Downsizing & Integrating Multiple Steps of Analysis (injection,

separation, reaction, and detection) onto a Single Device

Micro Total Analysis System (m-TAS) or Lab-on-a-chip (LOC)

Handling fluids on the nanoliter and picoliter scale

Laminar flow conditions (very low Reynold’s number)

diffusion controlled transport of molecules

Microfluidics is the science and technology of system that

manipulate small amount of fluidics (nanoliter to picoliter) using

channels measuring from tens to hundreds of micrometers.

Page 4: Recent Advances in Microfluidic Device Applications for ... · Applications for Environmental Monitoring and Toxicity Assessments ... (CE) well suited for ... Chem. (2009) Detection

Yager et al. Nature (2006)

mTAS or LOC

Miniaturization & Integration

Page 5: Recent Advances in Microfluidic Device Applications for ... · Applications for Environmental Monitoring and Toxicity Assessments ... (CE) well suited for ... Chem. (2009) Detection

Handling fluids

in nanoliter to picoliter scale

Downsizing system volumes

more than 1000 times

Cells

654 μm

145 μm

68 μm

PDMSCoverslip

PDMS

Volume of a Single Compartment

= 7.2 Χ 10-8 L

= 72 nL

c) Cell Culture

Compartments

Cell loading, Waste

a) Inlet

Pneumatic

Valve

b) Microfluidic

Diffusion Diluter

(µDD)

Outlet

Pneumatic

Valve

Media Toxicant

Page 6: Recent Advances in Microfluidic Device Applications for ... · Applications for Environmental Monitoring and Toxicity Assessments ... (CE) well suited for ... Chem. (2009) Detection

Demello A. J. Nature (2006)

Laminar flow condition provide

“diffusion” controlled transport

Enable accurate control of fluids

(e.g. formation of chemical gradient)

Compartme ntA

bso

rba

nce

0.00

0.05

0.10

0.15

0.20

0.25

0.30

0.35

0 h

After 12 h

a b c d e f g h i j

After 12 h

0 h

Page 7: Recent Advances in Microfluidic Device Applications for ... · Applications for Environmental Monitoring and Toxicity Assessments ... (CE) well suited for ... Chem. (2009) Detection

Low reagent consumption (Cheaper ! )

Low waste production (Less Hazardous !)

Rapid Analysis (Quicker !)

Simple & Robust (Portable & Disposable)

Page 8: Recent Advances in Microfluidic Device Applications for ... · Applications for Environmental Monitoring and Toxicity Assessments ... (CE) well suited for ... Chem. (2009) Detection

Sample Introduction

Sample Pre-concentration

Separation

Capillary Electrophoresis (CE)

Gas Chromatography (GC)

Detection

Optical Method – Fluorescence/Absorbance …

Electrochemical Method – Amperometric/Conductivity

Mass Spectrometry Method

Page 9: Recent Advances in Microfluidic Device Applications for ... · Applications for Environmental Monitoring and Toxicity Assessments ... (CE) well suited for ... Chem. (2009) Detection

Separation

Capillary Electrophoresis (CE)

well suited for minituariazation

w/o loosing separation efficiency

& analysis speed

Page 10: Recent Advances in Microfluidic Device Applications for ... · Applications for Environmental Monitoring and Toxicity Assessments ... (CE) well suited for ... Chem. (2009) Detection

Separation

Capillary Electrophoresis (CE)

Li H.-F. and Lin J.-M. Anal. Bioanal. Chem. (2009)

Page 11: Recent Advances in Microfluidic Device Applications for ... · Applications for Environmental Monitoring and Toxicity Assessments ... (CE) well suited for ... Chem. (2009) Detection

Detection

Optical Method – Fluorescence (Off-chip approach)

Li H.-F. et al. Anal. Chim. Acta (2006)

Page 12: Recent Advances in Microfluidic Device Applications for ... · Applications for Environmental Monitoring and Toxicity Assessments ... (CE) well suited for ... Chem. (2009) Detection

Detection

Optical Method – Fluorescence (On-chip approach)

Roulet et al. Anal. Chem. (2002)

Page 13: Recent Advances in Microfluidic Device Applications for ... · Applications for Environmental Monitoring and Toxicity Assessments ... (CE) well suited for ... Chem. (2009) Detection

Sample Detection

Limit

Detection

Method

Real

Sample

Ref.

Cd2+6 mg/L

Absorbance Water

Deng G. et al. (2003)

Pb2+1.8 mg/L J. Chromatogr. A

Co2+0.15 mg/L

Ni2+0.48 mg/L

Sulfite, nitrite 0.4-1 mg/L LIF River, Pond

and Rain water

Fujii S. et al. (2004)

Anal. Sci.

Nitrite, fluoride,

phosphate

0.5-0.7 mg/L Conductivity River, Tap,

Mineral water

Bodor R. et al. (2001)

J. Chromatogr. A

Page 14: Recent Advances in Microfluidic Device Applications for ... · Applications for Environmental Monitoring and Toxicity Assessments ... (CE) well suited for ... Chem. (2009) Detection

There are urgent needs for high-throughput (HTS) & high

content (HCS) screening biological assays, due to the

increasing numbers of new chemicals, such as manufactured

nanomaterials.

However, current in-vitro cytotoxicity assay methods using

multiwell plate systems are labor-intensive, expensive and have

limited capability to meet current needs.

Microfluidics may solve this problem by providing high-

throughput & high contents screening methods for in-vitro

toxicity assessments with much reduced costs

Page 15: Recent Advances in Microfluidic Device Applications for ... · Applications for Environmental Monitoring and Toxicity Assessments ... (CE) well suited for ... Chem. (2009) Detection

El-Ali J. et al. Nature (2006)

Downsizing & Integrating

Multiple Steps of Biological

Assay Protocols

onto a Single Chip

Page 16: Recent Advances in Microfluidic Device Applications for ... · Applications for Environmental Monitoring and Toxicity Assessments ... (CE) well suited for ... Chem. (2009) Detection

Hung et al. Biotech. Bioeng. (2005)

Under Continous Perfusion Flow

Page 17: Recent Advances in Microfluidic Device Applications for ... · Applications for Environmental Monitoring and Toxicity Assessments ... (CE) well suited for ... Chem. (2009) Detection

Hung et al. Biotech. Bioeng. (2005)

Page 18: Recent Advances in Microfluidic Device Applications for ... · Applications for Environmental Monitoring and Toxicity Assessments ... (CE) well suited for ... Chem. (2009) Detection

King et al. Lab on a Chip (2007)

Page 19: Recent Advances in Microfluidic Device Applications for ... · Applications for Environmental Monitoring and Toxicity Assessments ... (CE) well suited for ... Chem. (2009) Detection

King et al. Lab on a Chip (2007)

Page 20: Recent Advances in Microfluidic Device Applications for ... · Applications for Environmental Monitoring and Toxicity Assessments ... (CE) well suited for ... Chem. (2009) Detection

Wang et al. Lab on a Chip (2007)

Page 21: Recent Advances in Microfluidic Device Applications for ... · Applications for Environmental Monitoring and Toxicity Assessments ... (CE) well suited for ... Chem. (2009) Detection

Other Applications of Microfluidics

- Greener Synthesis of Quality Controlled Nanomaterials

Page 22: Recent Advances in Microfluidic Device Applications for ... · Applications for Environmental Monitoring and Toxicity Assessments ... (CE) well suited for ... Chem. (2009) Detection

Other Applications of Microfluidics

- Greener Synthesis of Nanomaterials

Page 23: Recent Advances in Microfluidic Device Applications for ... · Applications for Environmental Monitoring and Toxicity Assessments ... (CE) well suited for ... Chem. (2009) Detection

Low reagent consumption & waste production

Provide eco-friendly environmental monitoring and

biological assay methods

Portability due to simple & robust design

Generate large amount of temporal & spatial

information for on-line monitoring of environment

Fast analysis time & Accurate Control of Fluids

Enable High Throughput Measurements of Environmental

Samples and Biological Assays

Page 24: Recent Advances in Microfluidic Device Applications for ... · Applications for Environmental Monitoring and Toxicity Assessments ... (CE) well suited for ... Chem. (2009) Detection

Thanks for your attention !!