Top Banner
Realizing a Class 1 Ultrasonic Gas Meeter without HP Calibration - an innovative approaches contributing to an economic upstream metering solution Thomas Horst - Sick
19

Realizing a Class 1 Ultrasonic Gas Meeter without HP ...€¦ · without HP Calibration - an innovative approaches contributing to an economic upstream metering solution Thomas Horst

Apr 01, 2018

Download

Documents

nguyentruc
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Realizing a Class 1 Ultrasonic Gas Meeter without HP ...€¦ · without HP Calibration - an innovative approaches contributing to an economic upstream metering solution Thomas Horst

Realizing a Class 1 Ultrasonic Gas Meeter

without HP Calibration - an innovative

approaches contributing to an economic

upstream metering solution

Thomas Horst - Sick

Page 2: Realizing a Class 1 Ultrasonic Gas Meeter without HP ...€¦ · without HP Calibration - an innovative approaches contributing to an economic upstream metering solution Thomas Horst

REALIZING A CLASS 1 ULTRASONIC GAS FLOW METER WITHOUT HP CALIBRATION

Author: Thomas Horst - SICK AG

Co-Author: S. Stoof, A. Prade – SICK AG

European Flow Measurement Workshop 2015

Page 3: Realizing a Class 1 Ultrasonic Gas Meeter without HP ...€¦ · without HP Calibration - an innovative approaches contributing to an economic upstream metering solution Thomas Horst

2SICK Flow Solutions | European Flow Measurement Workshop 2015March 2015

GAS PRODUCTION APPLICATIONS

Challenging conditions in gas production:▸ Varying flow rates

▸ Varying gas quality

▸ Saturated gas streams with entrained liquids

Demand for meters that are:▸ Robust for use in production environments

▸ Economic in a long-term perspective

In fact: Meters for gas production applications are mainly covered by dP meters.

Page 4: Realizing a Class 1 Ultrasonic Gas Meeter without HP ...€¦ · without HP Calibration - an innovative approaches contributing to an economic upstream metering solution Thomas Horst

UPSTREAM MEETS ULTRASONICS

USM provide several advantages over dP meters:

( + ) Higher turn-down ratio( + ) Reduced pressure drop( + ) Virtually no maintenance( + ) Valuable diagnostics data

What about Ultrasonic meters in gas production?

USM are equally applicable:

• Highly robust, even for high LVF – no wear• Self-draining, self-recovering

3SICK Flow Solutions | European Flow Measurement Workshop 2015March 2015

Page 5: Realizing a Class 1 Ultrasonic Gas Meeter without HP ...€¦ · without HP Calibration - an innovative approaches contributing to an economic upstream metering solution Thomas Horst

COMPLETING THE VALUE CHAINUPSTREAM METERING WITH USM’S

Upstream Midstream Downstream

Production Gathering Transmission Storage Distribution Residential

4SICK Flow Solutions | European Flow Measurement Workshop 2015March 2015

Page 6: Realizing a Class 1 Ultrasonic Gas Meeter without HP ...€¦ · without HP Calibration - an innovative approaches contributing to an economic upstream metering solution Thomas Horst

Gathering SystemIf same owners, just 1 meter If different may be 1 owned by gatherer and sometimes a check meter on the pad

Multi Well Gas w / production and test separators• 2 to many wells• Each wells are cycled through a test separator, either

automatically or manually• On site facilities can be small to very large

Tanks or pipeline

Test Separator

ProductionSeparator

PRODUCTION CONFIGURATIONS

5SICK Flow Solutions | European Flow Measurement Workshop 2015March 2015

Page 7: Realizing a Class 1 Ultrasonic Gas Meeter without HP ...€¦ · without HP Calibration - an innovative approaches contributing to an economic upstream metering solution Thomas Horst

LARGE TURN-DOWN

FLOWSIC600 DRU covers typical range of 2..6 inch orifice plate meters.

6SICK Flow Solutions | European Flow Measurement Workshop 2015March 2015

Page 8: Realizing a Class 1 Ultrasonic Gas Meeter without HP ...€¦ · without HP Calibration - an innovative approaches contributing to an economic upstream metering solution Thomas Horst

� Dual path meter design

� Precise meter body manufacturing with tight tolerance limits

� Tailor-made US sensors and path layout

� Integrated 10D upstream piping

� Individual LP calibration

LOW UNCERTAINTY (CLASS 1 METER) WITHOUT INDIVIDUAL HIGH PRESSURE CALIBRATION

Meter body manufacturing precision

Superior transducer technology

Zero flow test and verification

In-house ambient air flow calibration

Quality assurance for HP natural gas

Steps to uncertainty: ±1%

� No individual HP calibration

� Significantly reducedsystem price.

7SICK Flow Solutions | European Flow Measurement Workshop 2015March 2015

Page 9: Realizing a Class 1 Ultrasonic Gas Meeter without HP ...€¦ · without HP Calibration - an innovative approaches contributing to an economic upstream metering solution Thomas Horst

EVALUATION ON A PRODUCTION LOT OF 25 METERSMANUFACTURING PRECISION

59,95

59,96

59,97

59,98

59,99

60

60,01

60,02

60,03

60,04

60,05

14

39

00

40

14

39

00

42

14

39

00

44

14

39

00

46

14

39

00

48

14

39

00

50

14

39

00

52

14

39

00

54

14

39

00

56

14

39

00

58

14

40

00

47

14

40

00

49

14

40

00

51

14

42

00

61

14

42

00

63

14

42

00

65

14

42

00

67

14

42

00

69

14

42

00

71

14

42

00

73

14

42

00

75

14

42

00

77

14

42

00

79

14

42

00

81

14

42

00

83

Pat

h an

gle

[deg

]

Path angle

Path 1 Path 2

Tolerance limit ±0.02 deg

134,8

134,85

134,9

134,95

135

135,05

135,1

135,15

14

39

00

40

14

39

00

42

14

39

00

44

14

39

00

46

14

39

00

48

14

39

00

50

14

39

00

52

14

39

00

54

14

39

00

56

14

39

00

58

14

40

00

47

14

40

00

49

14

40

00

51

14

42

00

61

14

42

00

63

14

42

00

65

14

42

00

67

14

42

00

69

14

42

00

71

14

42

00

73

14

42

00

75

14

42

00

77

14

42

00

79

14

42

00

81

14

42

00

83

Pat

h le

ngth

[mm

]

Path length

Path 1 Path 2

Tolerance limit ±0.1 mm

0

0,05

0,1

0,15

0,2

0,25

0,3

14

39

00

40

14

39

00

42

14

39

00

44

14

39

00

46

14

39

00

48

14

39

00

50

14

39

00

52

14

39

00

54

14

39

00

56

14

39

00

58

14

40

00

47

14

40

00

49

14

40

00

51

14

42

00

61

14

42

00

63

14

42

00

65

14

42

00

67

14

42

00

69

14

42

00

71

14

42

00

73

14

42

00

75

14

42

00

77

14

42

00

79

14

42

00

81

14

42

00

83Par

alle

ilism

[mm

]

Path Paralleilism

Tolerance limit <0.3 mm

21,9

22

22,1

22,2

22,3

22,4

14

39

00

40

14

39

00

42

14

39

00

44

14

39

00

46

14

39

00

48

14

39

00

50

14

39

00

52

14

39

00

54

14

39

00

56

14

39

00

58

14

40

00

47

14

40

00

49

14

40

00

51

14

42

00

61

14

42

00

63

14

42

00

65

14

42

00

67

14

42

00

69

14

42

00

71

14

42

00

73

14

42

00

75

14

42

00

77

14

42

00

79

14

42

00

81

14

42

00

83

Pat

h po

sitio

n [m

m]

Path position

Path 1 Path 2

Tolerance limit ±0.15 mm

8SICK Flow Solutions | European Flow Measurement Workshop 2015March 2015

Page 10: Realizing a Class 1 Ultrasonic Gas Meeter without HP ...€¦ · without HP Calibration - an innovative approaches contributing to an economic upstream metering solution Thomas Horst

AMBIENT AIR CALIBRATION RESULTS

-2,5

-2,0

-1,5

-1,0

-0,5

0,0

0,5

1,0

1,5

2,0

2,5

0 100 200 300 400 500 600 700

Err

or [%

]

Flow rate [m³/h]

Ambient air calibration – as left

RESULTS ON A PRODUCTION LOT OF 25 METERS

9SICK Flow Solutions | European Flow Measurement Workshop 2015March 2015

Page 11: Realizing a Class 1 Ultrasonic Gas Meeter without HP ...€¦ · without HP Calibration - an innovative approaches contributing to an economic upstream metering solution Thomas Horst

VERIFICATION OF OUT-OF-THE-BOX PERFORMANCE RESULTS ON HIGH PRESSURE TEST FACILITY

-2,5

-2,0

-1,5

-1,0

-0,5

0,0

0,5

1,0

1,5

2,0

2,5

0 100 200 300 400 500 600 700

Err

or [%

]

Flow rate [m³/h]

High pressure flow test – as found

4bar 50 bar Ambient Air 2bar

10SICK Flow Solutions | European Flow Measurement Workshop 2015March 2015

Page 12: Realizing a Class 1 Ultrasonic Gas Meeter without HP ...€¦ · without HP Calibration - an innovative approaches contributing to an economic upstream metering solution Thomas Horst

FLOW DISTURBANCE TEST RESULTS

-1,00

-0,75

-0,50

-0,25

0,00

0,25

0,50

0,75

1,00

6904802756934,5

Dev

iatio

n to

Bas

elin

e [%

]

Flow rate [m³/h]

Flow disturbance test of FLOWSIC600 DRUFC: CPA 55E, Distance: 10D, OIML R137 (mild) / ISO 17089

7094_S16 zurueck_CPA55E_10D_SEL 7099_S16 zurueck_CPA55E_10D_SER7100_S16 zurueck_CPA55E_10D_DER 7103_S16 zurueck_CPA55E_10D_DEL7104_S16 zurueck_MUT90Gr_CPA55E_10D_DEI 7108_S16 zurueck_CPA55E_10D_GV7110_S16 zurueck_CPA55E_10D_STP 7111_S16 zurueck_CPA55E_10D_CO7112_S16 zurueck_CPA55E_10D_DI

11SICK Flow Solutions | European Flow Measurement Workshop 2015March 2015

Page 13: Realizing a Class 1 Ultrasonic Gas Meeter without HP ...€¦ · without HP Calibration - an innovative approaches contributing to an economic upstream metering solution Thomas Horst

� Test at CEESI Nunn

� 13 barg and 55 barg

� 95..100% GVF

WET GAS TESTING

12SICK Flow Solutions | European Flow Measurement Workshop 2015March 2015

Page 14: Realizing a Class 1 Ultrasonic Gas Meeter without HP ...€¦ · without HP Calibration - an innovative approaches contributing to an economic upstream metering solution Thomas Horst

Comparison: dual chamber orifice with one beta (0,517) – Natural gas / WaterWET GAS TEST RESULTS

: Continuous operation for alltested LVF

: Acceptable allocation accuracy up to 0.5 % LVF

� USM is robust even in wet gas conditions

FLOWSIC600 DRUOrifice Meter Error Difference Relative to Dry GasPressure = 800 psia - With CPA

-5,0

0,0

5,0

10,0

15,0

20,0

25,0

30,0

35,0

40,0

45,0

0 10 20 30 40 50

Ref Gas Velocity (ft/s)

Error

GVF = 99.88

GVF = 99.76

GVF = 99.52

GVF = 98.83

GVF = 97.70

GVF = 95.44

2 Path Meter Error Difference Relative to Dry GasPressure = 800 psia - With CPA

-5,0

0,0

5,0

10,0

15,0

20,0

25,0

30,0

35,0

40,0

45,0

0 10 20 30 40 50

Ref Gas Velocity (ft/s)

Error

GVF = 99.88

GVF = 99.76

GVF = 99.52

GVF = 98.83

GVF = 97.70

GVF = 95.44

13SICK Flow Solutions | European Flow Measurement Workshop 2015March 2015

Page 15: Realizing a Class 1 Ultrasonic Gas Meeter without HP ...€¦ · without HP Calibration - an innovative approaches contributing to an economic upstream metering solution Thomas Horst

INNOVATIVE LIQUID DETECTION DIAGNOSTICS

� Fully automated monitoring of all diagnostic parameters

� Algorithm using diagnostics to generate a warning when liquids are present that may have an impact on process quality or measurement accuracy

� Operation expenditures stay low due to intelligent diagnostics telling you when maintenance and inspections are really necessary

14SICK Flow Solutions | European Flow Measurement Workshop 2015March 2015

Page 16: Realizing a Class 1 Ultrasonic Gas Meeter without HP ...€¦ · without HP Calibration - an innovative approaches contributing to an economic upstream metering solution Thomas Horst

� High rangeability

� Virtually maintenance-free

� Identification of time periods with potential measurement issues by inbuilt liquid detection

� Indication of measurement data quality

� Potential for production optimization to avoid liquid production

FLOWSIC600 DRU – CUSTOMER BENEFITS

15SICK Flow Solutions | European Flow Measurement Workshop 2015March 2015

Page 17: Realizing a Class 1 Ultrasonic Gas Meeter without HP ...€¦ · without HP Calibration - an innovative approaches contributing to an economic upstream metering solution Thomas Horst

� Measurement effects of wet gas on ultrasonic meters are significant and not trivial to overcome

� FLOWSIC600 DRU is not a wet gas meter , but is robust for wet gas production applications and provides substantial added value by

▸ Large turn-down

▸ Low OpEx

▸ Long-term stability

▸ Liquid detection diagnostic

� Further research must be done on liquid correction of USM

� Tests and projects are ongoing – results will be published subsequently

SUMMARY

16SICK Flow Solutions | European Flow Measurement Workshop 2015March 2015

Page 18: Realizing a Class 1 Ultrasonic Gas Meeter without HP ...€¦ · without HP Calibration - an innovative approaches contributing to an economic upstream metering solution Thomas Horst

What are main concerns for US metering in gas produ ction?

� Economic in CapEx and long-term perspective?

� Robust for production applications?

� Low measurement uncertainty?

� Diagnostic values with added value in upstream applications?

UPSTREAM MEETS ULTRASONICS

17SICK Flow Solutions | European Flow Measurement Workshop 2015March 2015

Page 19: Realizing a Class 1 Ultrasonic Gas Meeter without HP ...€¦ · without HP Calibration - an innovative approaches contributing to an economic upstream metering solution Thomas Horst

Thomas Horst

SICK Flow Solutions

[email protected]

MANY THANKS FOR YOUR ATTENTION.