RE208_Hardwire_to_Honeywell-Compat_Translator Page 1 of 4 24-Hour Tech Support Line: (715)808-0164 30-Oct-14 www.ResolutionProducts.com RE208 Hardwire-to-Honeywell ® or 2GIG ® Wireless Translator™ Features • Converts hardwire zones into Honeywell-compatible wireless signals. • 8 Hardwire loops with end-of-line resistor detection. • Unique wireless ID for each zone, plus 1 for main device. • Transmit diversity for long reliable range. • PIR powering (via external supply). • 3 year operation on batteries (contacts only). • Complete supervision of zone tampers and low battery. Key Instructions • DO NOT MOUNT IN A METAL CAN. • DO NOT PUT POWER ON HARDWIRE TERMINALS. • Use with normally closed contacts in-line with 4.7 K-ohms resistors (mandatory). • Not for use with life safety devices, such as Smoke or CO sensors. • External supply requirements: Contacts-only installations may use wall plug power supply (see specifications) Installations with PIRs or Glassbreaks (powered devices) require battery-backed external power supply (see diagram). Without backed-up power, PIRs or Glass Breaks could alarm when power is lost. Translator AA batteries drive contacts only, and do not drive powered devices. Ensure that external supply has sufficient current to supply all powered devices including Translator. 4-wire powered devices only. Not for use with 2-wire powered devices. If using old panel as the battery-backed 12V DC supply, verify supply and battery operation. DO NOT MOUNT IN OLD CAN… the wireless will not get out! Installation • Hook up PIR and Glass Break power lines to external power supply. • Alarm contact hook-up: Works only with normally-closed contacts (alarm = open). Remove any existing end-of-line resistors. Connect 4.7K end-of-line resistor (included) IN-LINE with contact. Resistor should NOT be across (between) terminals. Honeywell® Enrollment Sensors: RF Learning tripping enrollment mode. Set up for any behavior desired. Input Type: 3 (Supervised RF) When prompted, open/close each zone twice to enroll serial number. Ensure it is set to Loop: 2. Translator itself: RF Learning tripping enrollment mode. Zone Type: 8 (24 hour Aux) Input Type: 3 (Supervised RF), When prompted, toggle the tamper switch to enroll serial number. Loop 2 (but Loop doesn’t really matter). 2GIG® Enrollment: Sensors: Q1 RF Sensor Set up for any behavior desired. At “Enter RF Serial Number”, press SHIFT LEARN, and trip sensor. Ensure it is set to Loop 2. Translator itself: Sensor Type: (08) 24 Hour Aux Equipment Type: (1) contact Equipment Code: (0000) other Other Equipment Code: (208) meaning RE208 Enter RF Serial Number: [press SHIFT,Learn, then toggle the tamper switch to enroll the serial number] Equipment Age: (0) new Loop Number: (2) but Loop doesn’t really matter Dialer Delay: (1) enabled RE208_Hardwire_to_Honeywell-Compat_Translator Page 2 of 4 24-Hour Tech Support Line: (715)808-0164 30-Oct-14 www.ResolutionProducts.com • Application Diagram • Connection Diagram 4.7K Contact (Normally Closed) Loop x PIR To Enroll zone, Open and close contact. This sends a open/close signal to panel. Translator AA Batteries DO NOT power external devices Altronix AL100UL 12VDC Supply With Lead-acid battery Old Panel may be used, if operation fully verified +12 VDC GND PIR Power Input PIR Contact Output (Normally Closed) 4.7K Loop y Altronix TP1620 16.5VAC, 20VA Transformer with securing screw Resolution RE012 12 VDC Power Supply NON-Switched Outlet Use Battery-Backed 12VDC if powering PIRs or Glass Breaks Use Non-Battery-Backed Supply ONLY if installation is all non-powered contacts Power Supply polarity DOES NOT matter! End of Line Resistor New Wireless System Existing Hardwire Sensors New Honeywell Self-Contained System in living area Taking over old Hardwire panel, usually mounted in utility area Honeywell Wireless May use GE 60-898-ITI supply here, if securing screw is desired