OPERATOR’S MANUAL For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process Gasoline Engine Driven Welder and Power Generator IM511-D OCTOBER, 2000 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thought- ful operation on your part. DO NOT INSTALL, OPERATE OR REPAIR THIS EQUIPMENT WITHOUT READING THIS MANUAL AND THE SAFETY PRECAUTIONS CONTAINED THROUGHOUT. And, most importantly, think before you act and be careful. R • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com • World's Leader in Welding and Cutting Products • Date of Purchase: Serial Number: Code Number: Model: Where Purchased: Copyright © 2000 Lincoln Global Inc.
41

RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process

Jul 04, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process

OPERATOR’S MANUAL

For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550

RANGER TM 9Multi-Process Gasoline Engine Driven Welder and Power Generator

IM511-DOCTOBER, 2000

Safety Depends on YouLincoln arc welding and cuttingequipment is designed and builtwith safety in mind. However, youroverall safety can be increased byproper installation ... and thought-ful operation on your part. DONOT INSTALL, OPERATE ORREPAIR THIS EQUIPMENTWITHOUT READING THISMANUAL AND THE SAFETYPRECAUTIONS CONTAINEDTHROUGHOUT. And, mostimportantly, think before you actand be careful.

R

• Sales and Service through Subsidiaries and Distributors Worldwide •

Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com

• World's Leader in Welding and Cutting Products •

Date of Purchase:Serial Number:Code Number:Model:Where Purchased:

Copyright © 2000 Lincoln Global Inc.

Page 2: RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process

FOR ENGINEpowered equipment.

1.a. Turn the engine off before troubleshooting and maintenancework unless the maintenance work requires it to be running.

____________________________________________________1.b.Operate engines in open, well-ventilated

areas or vent the engine exhaust fumes outdoors.

____________________________________________________1.c. Do not add the fuel near an open flame

welding arc or when the engine is running.Stop the engine and allow it to cool beforerefueling to prevent spilled fuel from vaporiz-ing on contact with hot engine parts andigniting. Do not spill fuel when filling tank. Iffuel is spilled, wipe it up and do not startengine until fumes have been eliminated.

____________________________________________________1.d. Keep all equipment safety guards, covers and devices in

position and in good repair.Keep hands, hair, clothing andtools away from V-belts, gears, fans and all other moving partswhen starting, operating or repairing equipment.

____________________________________________________

1.e. In some cases it may be necessary to remove safetyguards to perform required maintenance. Removeguards only when necessary and replace them when themaintenance requiring their removal is complete.Always use the greatest care when working near movingparts.

___________________________________________________1.f. Do not put your hands near the engine fan.

Do not attempt to override the governor oridler by pushing on the throttle control rodswhile the engine is running.

___________________________________________________1.g. To prevent accidentally starting gasoline engines while

turning the engine or welding generator during maintenancework, disconnect the spark plug wires, distributor cap ormagneto wire as appropriate.

iSAFETYi

ARC WELDING CAN BE HAZARDOUS. PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH.KEEP CHILDREN AWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING.

Read and understand the following safety highlights. For additional safety information, it is strongly recommended that you pur-chase a copy of “Safety in Welding & Cutting - ANSI Standard Z49.1” from the American Welding Society, P.O. Box 351040,Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of “Arc Welding Safety” booklet E205 is available from theLincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.

BE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE AND REPAIR PROCEDURES AREPERFORMED ONLY BY QUALIFIED INDIVIDUALS.

WARNING

Mar ‘95

ELECTRIC AND MAGNETIC FIELDSmay be dangerous

2.a. Electric current flowing through any conductor causes localized Electric and Magnetic Fields (EMF). Welding current creates EMF fields around welding cables and welding machines

2.b. EMF fields may interfere with some pacemakers, andwelders having a pacemaker should consult their physicianbefore welding.

2.c. Exposure to EMF fields in welding may have other healtheffects which are now not known.

2.d. All welders should use the following procedures in order tominimize exposure to EMF fields from the welding circuit:

2.d.1. Route the electrode and work cables together - Securethem with tape when possible.

2.d.2. Never coil the electrode lead around your body.

2.d.3. Do not place your body between the electrode andwork cables. If the electrode cable is on your right side, the work cable should also be on your right side.

2.d.4. Connect the work cable to the workpiece as close aspossible to the area being welded.

2.d.5. Do not work next to welding power source.

1.h. To avoid scalding, do not remove theradiator pressure cap when the engine ishot.

CALIFORNIA PROPOSITION 65 WARNINGS

Diesel engine exhaust and some of its constituentsare known to the State of California to causecancer, birth defects, and other reproductive harm.

The engine exhaust from this product containschemicals known to the State of California to causecancer, birth defects, or other reproductive harm.

The Above For Diesel Engines The Above For Gasoline Engines

Page 3: RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process

iiSAFETYii

ARC RAYS can burn.4.a. Use a shield with the proper filter and cover

plates to protect your eyes from sparks andthe rays of the arc when welding or observingopen arc welding. Headshield and filter lensshould conform to ANSI Z87. I standards.

4.b. Use suitable clothing made from durable flame-resistantmaterial to protect your skin and that of your helpers fromthe arc rays.

4.c. Protect other nearby personnel with suitable, non-flammablescreening and/or warn them not to watch the arc nor exposethemselves to the arc rays or to hot spatter or metal.

ELECTRIC SHOCK can kill.3.a. The electrode and work (or ground) circuits

are electrically “hot” when the welder is on.Do not touch these “hot” parts with your bareskin or wet clothing. Wear dry, hole-freegloves to insulate hands.

3.b. Insulate yourself from work and ground using dry insulation.Make certain the insulation is large enough to cover your fullarea of physical contact with work and ground.

In addition to the normal safety precautions, if weldingmust be performed under electrically hazardousconditions (in damp locations or while wearing wetclothing; on metal structures such as floors, gratings orscaffolds; when in cramped positions such as sitting,kneeling or lying, if there is a high risk of unavoidable oraccidental contact with the workpiece or ground) usethe following equipment:

• Semiautomatic DC Constant Voltage (Wire) Welder.• DC Manual (Stick) Welder.• AC Welder with Reduced Voltage Control.

3.c. In semiautomatic or automatic wire welding, the electrode,electrode reel, welding head, nozzle or semiautomaticwelding gun are also electrically “hot”.

3.d. Always be sure the work cable makes a good electricalconnection with the metal being welded. The connectionshould be as close as possible to the area being welded.

3.e. Ground the work or metal to be welded to a good electrical(earth) ground.

3.f. Maintain the electrode holder, work clamp, welding cable andwelding machine in good, safe operating condition. Replacedamaged insulation.

3.g. Never dip the electrode in water for cooling.

3.h. Never simultaneously touch electrically “hot” parts ofelectrode holders connected to two welders because voltagebetween the two can be the total of the open circuit voltageof both welders.

3.i. When working above floor level, use a safety belt to protectyourself from a fall should you get a shock.

3.j. Also see Items 6.c. and 8.

FUMES AND GASEScan be dangerous.5.a. Welding may produce fumes and gases

hazardous to health. Avoid breathing thesefumes and gases.When welding, keepyour head out of the fume. Use enoughventilation and/or exhaust at the arc to keep

fumes and gases away from the breathing zone. Whenwelding with electrodes which require specialventilation such as stainless or hard facing (seeinstructions on container or MSDS) or on lead orcadmium plated steel and other metals or coatingswhich produce highly toxic fumes, keep exposure aslow as possible and below Threshold Limit Values (TLV)using local exhaust or mechanical ventilation. Inconfined spaces or in some circumstances, outdoors, arespirator may be required. Additional precautions arealso required when welding on galvanized steel.

5.b. Do not weld in locations near chlorinated hydrocarbon vaporscoming from degreasing, cleaning or spraying operations.The heat and rays of the arc can react with solvent vapors toform phosgene, a highly toxic gas, and other irritating products.

5.c. Shielding gases used for arc welding can displace air andcause injury or death. Always use enough ventilation,especially in confined areas, to insure breathing air is safe.

5.d. Read and understand the manufacturer’s instructions for thisequipment and the consumables to be used, including thematerial safety data sheet (MSDS) and follow youremployer’s safety practices. MSDS forms are available fromyour welding distributor or from the manufacturer.

5.e. Also see item 1.b. Mar ‘95

Page 4: RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process

FOR ELECTRICALLYpowered equipment.

8.a. Turn off input power using the disconnectswitch at the fuse box before working onthe equipment.

8.b. Install equipment in accordance with the U.S. NationalElectrical Code, all local codes and the manufacturer’srecommendations.

8.c. Ground the equipment in accordance with the U.S. NationalElectrical Code and the manufacturer’s recommendations.

CYLINDER may explodeif damaged.7.a. Use only compressed gas cylinders

containing the correct shielding gas for theprocess used and properly operatingregulators designed for the gas and

pressure used. All hoses, fittings, etc. should be suitable forthe application and maintained in good condition.

7.b. Always keep cylinders in an upright position securelychained to an undercarriage or fixed support.

7.c. Cylinders should be located:• Away from areas where they may be struck or subjected tophysical damage.

• A safe distance from arc welding or cutting operations andany other source of heat, sparks, or flame.

7.d. Never allow the electrode, electrode holder or any otherelectrically “hot” parts to touch a cylinder.

7.e. Keep your head and face away from the cylinder valve outletwhen opening the cylinder valve.

7.f. Valve protection caps should always be in place and handtight except when the cylinder is in use or connected foruse.

7.g. Read and follow the instructions on compressed gascylinders, associated equipment, and CGA publication P-l,“Precautions for Safe Handling of Compressed Gases inCylinders,” available from the Compressed Gas Association1235 Jefferson Davis Highway, Arlington, VA 22202.

iiiSAFETYiii

Mar ‘95

WELDING SPARKS cancause fire or explosion.6.a. Remove fire hazards from the welding area.

If this is not possible, cover them to preventthe welding sparks from starting a fire.Remember that welding sparks and hot

materials from welding can easily go through small cracksand openings to adjacent areas. Avoid welding nearhydraulic lines. Have a fire extinguisher readily available.

6.b. Where compressed gases are to be used at the job site,special precautions should be used to prevent hazardoussituations. Refer to “Safety in Welding and Cutting” (ANSIStandard Z49.1) and the operating information for theequipment being used.

6.c. When not welding, make certain no part of the electrodecircuit is touching the work or ground. Accidental contactcan cause overheating and create a fire hazard.

6.d. Do not heat, cut or weld tanks, drums or containers until theproper steps have been taken to insure that such procedureswill not cause flammable or toxic vapors from substancesinside. They can cause an explosion even though they havebeen “cleaned”. For information, purchase “RecommendedSafe Practices for the Preparation for Welding and Cutting ofContainers and Piping That Have Held HazardousSubstances”, AWS F4.1 from the American Welding Society(see address above).

6.e. Vent hollow castings or containers before heating, cutting orwelding. They may explode.

6.f. Sparks and spatter are thrown from the welding arc. Wear oilfree protective garments such as leather gloves, heavy shirt,cuffless trousers, high shoes and a cap over your hair. Wearear plugs when welding out of position or in confined places.Always wear safety glasses with side shields when in awelding area.

6.g. Connect the work cable to the work as close to the weldingarea as practical. Work cables connected to the buildingframework or other locations away from the welding areaincrease the possibility of the welding current passingthrough lifting chains, crane cables or other alternatecircuits. This can create fire hazards or overheat liftingchains or cables until they fail.

6.h. Also see item 1.c.

Page 5: RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process

ivSAFETYiv

PRÉCAUTIONS DE SÛRETÉPour votre propre protection lire et observer toutes les instruc-tions et les précautions de sûreté specifiques qui parraissent dansce manuel aussi bien que les précautions de sûreté généralessuivantes:

Sûreté Pour Soudage A L’Arc1. Protegez-vous contre la secousse électrique:

a. Les circuits à l’électrode et à la piéce sont sous tensionquand la machine à souder est en marche. Eviter toujourstout contact entre les parties sous tension et la peau nueou les vétements mouillés. Porter des gants secs et sanstrous pour isoler les mains.

b. Faire trés attention de bien s’isoler de la masse quand onsoude dans des endroits humides, ou sur un planchermetallique ou des grilles metalliques, principalement dans les positions assis ou couché pour lesquelles unegrande partie du corps peut être en contact avec lamasse.

c. Maintenir le porte-électrode, la pince de masse, le câblede soudage et la machine à souder en bon et sûr étatdefonctionnement.

d.Ne jamais plonger le porte-électrode dans l’eau pour lerefroidir.

e. Ne jamais toucher simultanément les parties sous tensiondes porte-électrodes connectés à deux machines àsouder parce que la tension entre les deux pinces peutêtre le total de la tension à vide des deux machines.

f. Si on utilise la machine à souder comme une source decourant pour soudage semi-automatique, ces precautionspour le porte-électrode s’applicuent aussi au pistolet desoudage.

2. Dans le cas de travail au dessus du niveau du sol, seprotéger contre les chutes dans le cas ou on recoit un choc.Ne jamais enrouler le câble-électrode autour de n’importequelle partie du corps.

3. Un coup d’arc peut être plus sévère qu’un coup de soliel,donc:

a. Utiliser un bon masque avec un verre filtrant appropriéainsi qu’un verre blanc afin de se protéger les yeux durayonnement de l’arc et des projections quand on soudeou quand on regarde l’arc.

b. Porter des vêtements convenables afin de protéger la peaude soudeur et des aides contre le rayonnement de l‘arc.

c. Protéger l’autre personnel travaillant à proximité ausoudage à l’aide d’écrans appropriés et non-inflammables.

4. Des gouttes de laitier en fusion sont émises de l’arc desoudage. Se protéger avec des vêtements de protectionlibres de l’huile, tels que les gants en cuir, chemise épaisse,pantalons sans revers, et chaussures montantes.

5. Toujours porter des lunettes de sécurité dans la zone de

soudage. Utiliser des lunettes avec écrans lateraux dans leszones où l’on pique le laitier.

6. Eloigner les matériaux inflammables ou les recouvrir afin deprévenir tout risque d’incendie dû aux étincelles.

7. Quand on ne soude pas, poser la pince à une endroit isolé dela masse. Un court-circuit accidental peut provoquer unéchauffement et un risque d’incendie.

8. S’assurer que la masse est connectée le plus prés possiblede la zone de travail qu’il est pratique de le faire. Si on placela masse sur la charpente de la construction ou d’autresendroits éloignés de la zone de travail, on augmente le risquede voir passer le courant de soudage par les chaines delevage, câbles de grue, ou autres circuits. Cela peut provo-quer des risques d’incendie ou d’echauffement des chaines etdes câbles jusqu’à ce qu’ils se rompent.

9. Assurer une ventilation suffisante dans la zone de soudage.Ceci est particuliérement important pour le soudage de tôlesgalvanisées plombées, ou cadmiées ou tout autre métal quiproduit des fumeés toxiques.

10. Ne pas souder en présence de vapeurs de chlore provenantd’opérations de dégraissage, nettoyage ou pistolage. Lachaleur ou les rayons de l’arc peuvent réagir avec lesvapeurs du solvant pour produire du phosgéne (gasfortement toxique) ou autres produits irritants.

11. Pour obtenir de plus amples renseignements sur la sûreté,voir le code “Code for safety in welding and cutting” CSAStandard W 117.2-1974.

PRÉCAUTIONS DE SÛRETÉ POURLES MACHINES À SOUDER ÀTRANSFORMATEUR ET ÀREDRESSEUR

1. Relier à la terre le chassis du poste conformement au code del’électricité et aux recommendations du fabricant. Ledispositif de montage ou la piece à souder doit être branchéà une bonne mise à la terre.

2. Autant que possible, I’installation et l’entretien du poste seronteffectués par un électricien qualifié.

3. Avant de faires des travaux à l’interieur de poste, ladebrancher à l’interrupteur à la boite de fusibles.

4. Garder tous les couvercles et dispositifs de sûreté àleurplace.

Mar. ‘93

Page 6: RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process

Thank You for selecting a QUALITY product by Lincoln Electric. We want youto take pride in operating this Lincoln Electric Company product •••as much pride as we have in bringing this product to you!

Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep ithandy for quick reference. Pay particular attention to the safety instructions we have provided for your protection.The level of seriousness to be applied to each is explained below:

WARNINGThis statement appears where the information must be followed exactly to avoid serious personal injury orloss of life.

This statement appears where the information must be followed to avoid minor personal injury or damage tothis equipment.

CAUTION

Please Examine Carton and Equipment For Damage ImmediatelyWhen this equipment is shipped, title passes to the purchaser upon receipt by the carrier. Consequently, Claimsfor material damaged in shipment must be made by the purchaser against the transportation company at thetime the shipment is received.

Please record your equipment identification information below for future reference. This information can be foundon your machine nameplate.

Model Name & Number _____________________________________

Code & Serial Number _____________________________________

Date of Purchase _____________________________________

Whenever you request replacement parts for or information on this equipment always supply the information youhave recorded above.

vv

Page 7: RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process

TABLE OF CONTENTS

Safety Precautions ............................................................................................................ii-ivIntroductory Information......................................................................................................vGeneral Description ............................................................................................................7Specifications ....................................................................................................................7-8Optional Features ...............................................................................................................9Recommended Equipment ................................................................................................10Installation Instructions....................................................................................................11-12

Machine Grounding .......................................................................................................11Spark Arrester ...............................................................................................................11Trailers ........................................................................................................................11-12

Pre-Operation Service .......................................................................................................12Oil ..................................................................................................................................12Fuel ...............................................................................................................................12Battery Connection........................................................................................................12Welding Output Cables .................................................................................................12Location/Ventilation .......................................................................................................12

Operation ........................................................................................................................13-14High Altitude Operation .................................................................................................13Muffler Relocation .........................................................................................................13Connection of Wire Feeders .........................................................................................13Connection of K428 or K446 with K624-1 Remote Output Module ..............................13Connection of K449 to the Ranger 9 ............................................................................13Connection of LN-7 or LN-8 to the Ranger 9................................................................14Connection of the LN-742 to the Ranger 9 ...................................................................14Connection of the Magnum Spool Gun and SG Control Module to the Ranger 9........14Remote Output Control .................................................................................................14High Frequency Generator for TIG welding applications .............................................14

Operating Instructions .....................................................................................................15-17Additional Safety Precautions .......................................................................................15Welder Operation ..........................................................................................................15Welder Controls, Functions, and Operation................................................................15-16Engine Operation........................................................................................................16-17Welding Processes .....................................................................................................17-18Auxiliary Power ...........................................................................................................19-20 Standby Power Information and Connection to Premises Wiring Diagram ............... 20-21

Maintenance....................................................................................................................22-23General Instructions ......................................................................................................22Engine Adjustments ......................................................................................................22Slip Rings ......................................................................................................................22Battery ...........................................................................................................................23Hardware.......................................................................................................................23

Troubleshooting ...............................................................................................................24-27General Troubleshooting ...............................................................................................24Electronic Idler Troubleshooting ....................................................................................25Output System Troubleshooting..................................................................................26-27

Wiring Diagram ...............................................................................................................28-30Connection Diagrams......................................................................................................31-35Dimension Print .................................................................................................................36Parts Pages ...............................................................................................................P230 Series

Page 8: RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process
Page 9: RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process

- 7 -

GENERAL DESCRIPTIONThe Ranger™ 9, is a twin cylinder gasoline enginedriven multi-process arc welder and AC powergenerator. It is built in a heavy gauge steel case fordurability on the job site.

RECOMMENDED PROCESSES ANDEQUIPMENTThe Ranger 9 can be used for AC/DC Stick welding(CC), DC Semiautomatic wire feed welding (CV),AC/DC Tig welding (CC), and also offers a 9,000 WattAC 115/230 Volt, 60 Hertz power generator.

For AC/DC Stick welding, the range is 40-250 Amps.There is a 100% duty cycle on all settings. TheOutput selector covers six ranges with remote outputcontrol for fine current adjustment. For use with abroad range of AC and DC electrodes includingFleetweld® 5P.

For DC Semi-automatic wire feed welding, threeconstant voltage wire feed welding settings areavailable giving a range of 40-250 Amps at 100% dutycycle. Excellent performance will be obtained with abroad range of Innershield® and Outershield®electrodes (FCAW). Excellent arc characteristics areavailable with MIG (GMAW). An output contactor isprovided for optimum semiautomatic welding.

AC and DC Tig welding can be done at all constantcurrent output settings.

The auxiliary power is provided by a 9,000 Watt, AC115/230 Volt, 60 Hertz generator. It will operate ACpower tools. It will also power a 1.5 HP motor (ifstarted under no load). It is capable of lighting ninety100 Watt incandescent bulbs, and can also be usedfor standby emergency power.

The Ranger 9 CSA machine (K1420-2) has four 15amp circuit breakers for 115V auxiliary receptaclesand two 50 amp circuit breakers for 230V receptacles.This machine is CSA approved.

SPECIFICATIONS

AC STICK / TIG (CC) OUTPUT

OU

TP

UT

VO

LT

S A

C

80

70

60

50

40

30

20

10

00 50 100 150 200 250 300 350

OUTPUT AMPS

B

B

A

A 250 OUTPUT RANGE

45 OUTPUT RANGE

DC STICK / TIG (CC) OUTPUT

OU

TP

UT

VO

LT

S D

C

80

70

60

50

40

30

20

10

00 50 100 150 200 250 300 350 400 450

OUTPUT AMPS

A

A

B

B

250 OUTPUT RANGE

45 OUTPUT RANGE

DC WIRE FEED (CV) OUTPUT

OU

TP

UT

VO

LT

S D

C

OUTPUT AMPS0 50 100 150 200 250 300 350 400

LOWMED

HIGH

5550454035

3025201510

50

Page 10: RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process

Ranger 9(Kohler Command

CH20S)

20 HP @ 3600 RPM

38.1 cu in(624 cc)

Fuel:9 Gal (34 L)

Lubricating Oil:2.0 Qts (1.9 L)

ProductName

Description Horsepower OperatingSpeeds

Displacement Ignition Capacities

Machine

Engine

* Based on a 10 min. period.

** When welding, available AC auxiliary power will be reduced.

115V will operate either 60Hz or 50/60Hz power tools, lights, etc.

- 8 -

SPECIFICATIONS

Product

Name

Ordering

Information

K1420-1

K1420-2

CSA(Meets

Canadian

Standards)

Ranger 9(Onan)

Ranger 9(Kohler)

K1421-1CSA

(MeetsCanadian

Standards)

Rated DC Output *

Amps / Volts / Duty Cycle

AC Constant Current

250A / 25V / 100%

DC Constant Current

250A / 25V / 100%

DC Constant Voltage

250A / 25V / 100%

Max OCV @ 3700 RPM

80V

Auxiliary Power for

Wire Feeders

42V, 60 Hz, 8 Amps

115V, 60 Hz, 8 Amps

AC Power ** Dimensions

& Weight

9,000 Watts

60 Hz. DC

80 Amps @

115V

40 Amps @

230V

30.3 x 19.2 x 42.3 in

(770 x 488 x 1075 mm)

598 lbs (272 kg)

30.3 x 19.2 x 42.3 in

(770 x 488 x 1075 mm)

591 lbs (269 kg)

Description

250 Amp

AC/DC

Multi-Process

Arc Welder

with

9,000 Watts AC

Auxiliary

Power

Ranger 9(Onan P218)

2 Cylinder4 Cycle

Air-CooledGasoline Engine.Aluminum Alloy

Block with Cast IronLiners, Electronic

Ignition

18 HP @ 3600 RPM

Full Load:3500 RPM

High Idle:3700 RPM

Low Idle:2200 RPM

47.7 cu in(782 cc)

12V Battery, 430Cold Cranking

Amps, Toggle StartSwitch, ChargingAmmeter, Manual

Choke

Fuel:9 Gal (34 L)

Lubricating Oil:1.8 Qts (1.7 L)

Page 11: RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process

A) K768-2 Two Wheel Undercarriage

For in-plant and yard towing. (For highway use,consult applicable federal, state, and local lawsregarding possible requirements for brakes, lights,fenders, etc.) Two 4.80 x 12" four-ply tubeless tires.Bed-plate mounting. Has stand for tow bar and gripsfor hand pulling. Overall width 43.06" (1.09 m).

B) K886-1 Canvas Cover

To protect the Ranger 9 when not in use. Made fromattractive red canvas material that is flame retardant,mildew resistant, and water repellent.

C) K894-1 Spark Arrester Kit

Includes a heavy gauge steel, approved sparkarrester and clamp for easy mounting to mufflerexhaust pipe.

D) K896-1 GFCI Receptacle Kit

Includes two UL approved 115 Volt ground fault circuitinterrupter duplex type receptacles with covers andinstallation instructions. Replaces the two factoryinstalled 115 Volt duplex receptacles. Each recepta-cle of each GFCI duplex is rated at 15 Amps but themaximum total current from each GFCI duplex islimited to 20 amps.

E) K930-1 TIG Module

Provides high frequency and shielding gas control forAC and DC GTAW (TIG) welding applications.Compact case is designed for easy carrying,complete with handle. High frequency bypass is builtin. The K939-1 Docking Kit is available for mountingthe TIG Module on top of the Ranger 9. The K936-1control cable is required.

F) K933-1 Four Wheel Undercarriage

Allows movement of the Ranger 9 by hand withoutlifting. Easily assembles to the Ranger 9. It includestwo rugged, hard molded wheels and two durablepneumatic tires. The spring loaded handle providesconvenient, comfortable steering. The k934-1 Bracketis available for mounting a gas cylinder on the under-carriage.

G) K934-1 Bracket for Mounting a Gas Cylinder to aK933-1 Undercarriage

Easily mounts on the back of the K933-1 Four WheelUndercarriage to carry a welding gas cylinder.

H) K889-2 Two Wheel Undercarriage

For moving by hand. Two 4.00" x 8" industrial tires.Overall width 29" (.74m).

I) K857 Remote Control

Consists of a control box with 25' (7.5 m) of fourconductor cable. Permits remote adjustment of outputvoltage.

J) K893-1 Caster for Two Wheel Undercarriage

Mounts to the front of the K889-2 Two-WheelUndercarriage to allow easy movement on smoothsurfaces. Includes a 6" diameter hard rubber wheelwith a convenient toe-on, toe-off locking brake.

K) K702 Accessory Kit

Accessory Set includes 35 ft. 2 AWG electrode cable,30 ft. 2 AWG work cable, headshield with number 12filter, work clamp, and Cooltong® 300 electrodeholder. Cables are rated at 250 Amps, 40% dutycycle.

L) K802-R Power Plug Kit

Provides four 115 Volt plugs rated at 15 Amps eachand one dual voltage, full KVA plug rated at 115/230Volts, 50 amps.

M) K802-N Power Plug KIt

Provides four 115 Volt plugs rated at 20 Amps eachand one dual voltage, full KVA plug rated at 115/230Volts, 50 Amps. (Not for use with K1420-2 CSAmachine and machines with GFCI receptacles.)

OPTIONAL FEATURES

- 9 -

Page 12: RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process

RECOMMENDED EQUIPMENT

STICK

K702 Accessory Kit which includes:

• Electrode holder and cable• Work clamp and cable• Headshield

K857 Remote Control Kit is optional for remotecurrent control.

WIRE FEED

LN-25 (K428 or K446) with K624-1 42 Volt RemoteOutput Control Module - Requires K626-xx ControlCable. Provides "cold" electrode until gun trigger ispressed. Voltage control is at the feeder. K446LN-25 includes gas solenoid.

LN-25 (K449) Includes internal contactor for acrossthe arc operation (no control cable). Provides "cold"electrode until gun trigger is pressed. Includes gassolenoid. K444-1 Remote Voltage Control Kit isrequired for voltage control at the feeder.

LN-742 (K617-1 or K618-1) or LN-742H (K617-2 orK618-2), requires K619-xx Input Cable Assembly.Provides "cold" electrode until gun trigger is pressed.Includes gas solenoid. K589-1 Remote Control Kitconnects to the LN-742 to provide remote voltage andwire speed control or K857 Remote Voltage ControlKit connects to the Ranger 9 for voltage control at thefeeder.

LN-7 (K521) or LN-7 GMA (K440), requires K584-xxInput Cable Assembly. Provides "cold" electrode untilgun trigger is pressed. K440 LN-7 GMA included gassolenoid. K8567 Remote Voltage Control Kit isrequired for voltage control at the feeder. Ranger 9must be operated at "HIGH" idle.

Magnum Gun is required for gas-shielded welding.Innershield Gun is required for gas-less welding.

TIG

Magnum™ TIG TorchMagnum Parts Kit and Argon gasK930-1 TIG ModuleK936-1 Control Cable

Optional:

K939-1 TIG Module Docking KitK963 Hand Amptrol™

K870 Foot AmptrolK814 Arc Start Switch

- 10 -

Page 13: RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process

INSTALLATION INSTRUCTIONS

Machine Grounding

Because this por table engine driven welder orgenerator creates it’s own power, it is not necessaryto connect it’s frame to an earth ground, unless themachine is connected to premises wiring (your home,shop, etc.).

To prevent dangerous electric shock, other equipmentto which this engine driven welder supplies powermust:

a. be grounded to the frame of the welder using a grounded type plug, or

b. be double insulated.

When this welder is mounted on a truck or trailer, it’sframe must be securely connected to the metal frameof the vehicle.

Where this engine driven welder is connected topremises wiring, such as that in your home or shop,it’s frame must be connected to the system earthground. See further connection instructions in thesection entitled Standby Power Connections in thismanual, as well as the article on grounding in thelatest U.S. National Electrical Code and the localcode.

In general, if the machine is to be grounded, it shouldbe connected with a #8 or larger copper wire to asolid earth ground such as a metal water pipe goinginto the ground for at least ten feet and having noinsulated joints, or to the metal framework of abuilding which has been effectively grounded. TheU.S. National Electrical Code lists a number ofalternate means of grounding electrical equipment. Amachine grounding stud marked with the symbolis provided on the front of the welder.

Spark Arrester

Some federal, state or local laws may require thatgasoline engines be equipped with exhaust sparkarresters when they are operated in certain locationswhere unarrested sparks may present a fire hazard.The standard muffler included with this welder doesnot qualify as a spark arrester. When required bylocal regulations, the K894-1 arrester must beinstalled and properly maintained.

-11 -

Undercarriages

The recommended undercarriage for use with thisequipment for in-plant and yard towing by a vehicle (1)

is Lincoln’s K768-2. If the user adapts a non-Lincolnundercarriage, he must assume responsibility that themethod of attachment and usage does not result in asafety hazard nor damage the welding equipment.Some of the factors to be considered are as follows:

(1) Consult applicable federal, state and local lawsregarding specific requirements for use on publichighways.

1. Design capacity of undercarriage vs. weight ofLincoln equipment and likely additionalattachments.

2. Proper support of, and attachment to, the base ofthe welding equipment so there will be no unduestress to the framework.

3. Proper placement of the equipment on theundercarriage to ensure stability side to side and front to back when being moved and when standing by itself while being operated or serviced.

Use of an incorrect arrester may lead to enginedamage or performance loss.-----------------------------------------------------------------------

Do not attempt to use this equipment until youhave thoroughly read the engine manufacturer’smanual supplied with your welder. It includesimportant safety precautions, detailed enginestarting, operating and maintenance instructions,and parts lists.------------------------------------------------------------------------

ELECTRIC SHOCK can kill.• Do not touch electrically live parts or

electrode with skin or wet clothing.• Insulate yourself from work and

ground• Always wear dry insulating gloves.

------------------------------------------------------------------------ENGINE EXHAUST can kill.• Use in open, well ventilated areas or

vent exhaust outside.

------------------------------------------------------------------------MOVING PARTS can injure.• Do not operate with doors open or

guards off.• Stop engine before servicing.• Keep away from moving parts.

------------------------------------------------------------------------

See additional warning information atfront of this operator’s manual.

-----------------------------------------------------------

WARNING

CAUTION

Page 14: RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process

4. Typical conditions of use, i.e., travel speed; rough-ness of surface on which the trailer will beoperated; environmental conditions; likemaintenance.

5. Conformance with federal, state and local laws.(1)

(1) Consult applicable federal, state and local laws regardingspecific requirements for use on public highways.

PRE-OPERATION SERVICE

READ the engine operating and maintenance instruc-tions supplied with this machine.------------------------------------------------------------------------

The Ranger 9 is shipped with the engine crankcasefilled with SAE 10W-30 oil. Check the oil level beforestarting the engine. It if is not up to the full mark onthe dipstick, add oil as required. Make certain that theoil filter cap is tightened securely. Refer to the engineOperators Manual for specific oil recommendations.

Oil

FuelFill the fuel tank with clean, fresh lead-free gasoline.The capacity is approximately 9 gallons (34 liters).Observe the fuel gauge while filling to prevent overfill-ing.

Battery Connection

This welder is shipped with the negative battery cabledisconnected. Make sure that the Engine Switch is inthe “STOP” position and attach the disconnectedcable securely to the negative battery terminal beforeattempting to operate the machine. If the battery isdischarged and does not have enough power to startthe engine, see the Maintenance-Battery section ofthis manual for battery charging instructions.

Welding Output Cables

With the engine off, connect the electrode and workcables to the studs provided. These connectionsshould be checked periodically and tightened ifnecessary.

Listed below are copper cable sizes recommended forthe rated current and duty cycle. Lengths stipulatedare the distance from the welder to work and back tothe welder again. Cable sizes are increased forgreater lengths primarily for the purpose of minimizingcable voltage drop.

TOTAL COMBINED LENGTH OFELECTRODE AND WORK CABLES

0-50 Ft.

50-100 Ft.

100-150 Ft.

150-200 Ft.

200-250 Ft.

250 Amps40% Duty Cycle

2 AWG

2 AWG

1 AWG

1 AWG

1/0 AWG

250 Amps100% Duty Cycle

1 AWG

1 AWG

1 AWG

1 AWG

1/0 AWG

Location / Ventilation

The welder should be located to provide an unrestrict-ed flow of clean, cool air to the cooling air inlets andto avoid heated air coming out of the back of thewelder recirculating back to the cooling air inletsbelow the exhaust. Also, locate the welder so that theengine exhaust fumes are properly vented to anoutside area.

Damage to fuel tank may cause fire or explosion.Do NOT drill holes in the Ranger 9 base or weld tothe Ranger 9 base.------------------------------------------------------------------------

-12 -

CAUTION

GASOLINE fuel can cause fire orexplosion.• Stop engine while fueling.• Do not smoke when fueling.• Do not overfill tank.

• Keep sparks and flame away from tank.• Wipe up spilled fuel and allow fumes to clear

before starting engine.

WARNING

WARNING

LUBRICATION SYSTEM CAPACITY(INCLUDING FILTER)

Onan P218 - 1.8 Quarts (1.7 Liters)Kohler CH20S - 2.0 Quarts (1.9 Liters)

Page 15: RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process

-13 -

Angle of Operation

Engines are designed to run in the level conditionwhich is where the optimum performance is achieved.The maximum angle of operation for the engine is 15degrees from horizontal in any direction. If the engineis to be operated at an angle, provisions must bemade for checking and maintaining the oil level at thenormal (FULL) oil capacity in the crankcase.

When operating the welder at an angle, the effectivefuel capacity will be slightly less than the specified 10gallons.

High Altitude Operation

If the Ranger 9 will be consistently operated ataltitudes above 5,000 feet, a carburetor jet designedfor high altitudes should be installed. This will result inbetter fuel economy, cleaner exhaust, and longerspark plug life. It will not give increased power whichis decreased at higher altitudes. Engine horsepower isreduced by 3.5% per 1000 feet for altitudes above 377feet.High altitude jet kits are available from the enginemanufacturer. Order Onan kit part number 146-0458.

Connection of Lincoln ElectricWire Feeders

Shut off welder before making any electricalconnections.------------------------------------------------------------------------Connection of K428 or K446 LN-25 withK624-1 42 volt Remote Output ControlModule to the Ranger 9.Requires K626-xx Control Cable. Provides “cold” electrodeuntil gun trigger is pressed and also provides voltage control atthe feeder. The K446 LN-25 includes a gas solenoid. See theappropriate connection diagram in rear of this manual.

a. Shut off the welder.

b. Connect the electrode cable from the LN-25 to the“ELECTRODE” stud of the welder. Connect thework cable to the “TO WORK” stud of the welder.

c. Connect the control cable from the LN-25 to the14 pin amphenol on the Ranger 9.

d. Attach the single lead from the front of the LN-25to the work using the spring clip on the end of thelead.

This is a control lead to supply the current to the wire feeder motor; it does not carry weldingcurrent.

e. Set the “POLARITY” switch to either WIRE FEEDDC+ or WIRE FEED DC- as required by theelectrode being used.

f. Set the “RANGE” switch to either HIGH, MED orLOW as required by the process.

g. Set the “WELDING TERMINALS” Control switch tothe “REMOTELY CONTROLLED” position.

h. Set the “IDLER” switch to the “AUTO” position.

Connection of the K449 LN-25 to theRanger 9.

a. Shut off the welder.

b. Connect the electrode cable from the LN-25 to the“ELECTRODE” stud of the welder. Connect thework cable to the “TO WORK” stud of the welder.

c. Attach the single lead from the front of the LN-25 towork using the spring clip on the end of the lead.This is a control lead to supply the current to thewire feeder motor; it does not carry welding current.

Do not operate a Ranger 9 with a high altitude jet installedat an altitude below 5,000 ft. This will result in the enginerunning too lean and result in higher engine temperatureswhich can shorten engine life.------------------------------------------------------------------------Muffler Relocation

Shut off welder and allow muffler to cool beforetouching muffler.------------------------------------------------------------------------The Ranger 9 is shipped with the exhaust coming out onthe left side of the machine. The exhaust can be changedto the opposite side by removing the two screws that holdthe exhaust port cover in place and installing the cover onthe opposite side. (Operating the Ranger 9 without thecover in place will result in a higher noise level and noincrease in machine output.)

CAUTION

WARNING

WARNING

Page 16: RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process

d. Set the “POLARITY” switch to either WIRE FEEDDC+ or WIRE FEED DC- as required by theelectrode being used.

e. Set the “RANGE” switch to either HIGH, MED orLOW as required by the process.

f. Set the “WELDING TERMINAL” Control switch to the “ALWAYS ON” position.

g. Set the “IDLER” switch to the “AUTO” position.

Connection of the LN-7 or LN-8 to theRanger 9.

a. Shut off the welder.

b. Connect the LN-7 or LN-8 per the instructions on the appropriate connection diagram in the rear of thismanual.

c. Set the output control toggle switch to appropriateposition: “CONTROL REMOTE” for LN-8 and LN-7with K857 attached; “CONTROL AT WELDER” forLN-7 with no remote voltage control.

d. Set “POLARITY” switch to either WIRE FEED DC+or WIRE FEED DC-.

e. Set the “RANGE” switch to either HIGH, MED orLOW as required by the process.

f. Set the “WELDING TERMINALS” Control switch tothe “REMOTELY CONTROLLED” position.

g. Set the “IDLER” switch to the “HIGH” idle position.

Connection of the LN-742 to the Ranger 9

a. Shut off the welder.

b. Connect per the instructions on the appropriateconnection diagram in rear of this manual.

c. Set the output control toggle switch to“CONTROL AT WELDER” when not usingremote control. When the LN-742 has a K589-1remote control attached, set output control to“REMOTE”.

d. Set “POLARITY” switch to either WIRE FEEDDC+ or WIRE FEED DC-.

e. Set “RANGE” switch to either HIGH, MED orLOW as required by the process.

f. Set the “WELDING TERMINAL” control switch to“REMOTELY CONTROLLED” position.

g. Set the “IDLER” switch to the “AUTO” position.

-14 -

Connection of the Magnum Spool Gunand SG Control Module to the Ranger 9

a. Shut off the Welder.

b. Connect per the instructions on the appropriateconnection diagram in the rear of this manual.

c. Set the output control toggle switch to “CONTROL AT WELDER” when not using remote control.

d. Set the “POLARITY” switch to WIRE FEED DC+.

e. Set the “RANGE” switch to either HIGH, MED orLOW as required by the process.

f. Set the “WELDING TERMINALS” Control switch tothe “REMOTELY CONTROLLED” position.

g. Set the “IDLER” switch to the “HIGH” idle position.

Remote Output Control

The Ranger 9 has a 6-pin and a 14-pin Amphenolconnector. These connectors are located above theoutput studs. The 6-pin connector is intended to beused with the optional K857 Remote Output Control orin the case of TIG welding applications, with the Footor Hand Amptrol. The 14-pin connector is used toconnect a wire feeder control cable. If the wire feederhas a built-in power source output control, do notconnect a remote output control to the 6-pinconnector. When remote output control is used, theoutput control toggle switch is to be set at “CONTROLREMOTE”.

High Frequency Generator for TIGwelding applications

The K930-1 TIG Module is an accessory that provideshigh frequency and shielding gas control for AC andDC GTAW (TIG) welding. See IM528 supplied withthe TIG Module for installation instructions.

Note: The TIG Module does not require the use of ahigh frequency bypass capacitor. If any other highfrequency accessory is used with the Ranger 9, abypass capacitor (Order Kit T12246) must be installedin the Ranger 9.

Page 17: RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process

Welder Controls - Function and Operation

ENGINE “ON-OFF” Switch

When placed in the “ON” posit ion, this switchenergizes the engine ignition circuit. When placed inthe “OFF” position, the ignition circuit is de-energizedto shut down the engine.

ENGINE “START” Push-Button Switch

Energizes engine starter motor.

“POLARITY” Switch

Three STICK/TIG (constant current) polarity settings:DC+, DC- and AC

Two wire feed (constant voltage) settings:DC+ and DC-

NOTE: The setting of this switch must match thecolor band setting of the Range Switch (both switchesmust be set for the same welding process).

OPERATING INSTRUCTIONS

Additional Safety Precautions

Always operate the welder with the roof and casesides in place as this provides maximum protectionfrom moving parts and assures proper cooling air flow.

Read carefully the Safety Precautions page in theInstruction Manual before operating this machine.Always follow these and any other safety proceduresincluded in this manual and in the Engine InstructionManual.

Welder Operation

Welder Output

• Maximum Open Circuit Voltage at 3700 RPM is 80 volts.

• Duty Cycle: 100% for both welding and auxiliary power.

Constant 250 amps AC @ 25 voltsCurrent 250 amps DC @ 25 volts

Constant 250 amps DC @ 25 voltsVoltage

RANGER 9

ONAN P218PERFORMER

KOHLERCH20S

Low Idle - No Load

2200 RPM

High Idle - No Load

3700 RPM

AC CC Weld Output

250 Amps @ 25 Volts

DC CC Weld Output

250 Amps @ 25 Volts

DC CV Weld Output

250 Amps @ 25 Volts

Auxiliary Power

9000 kVA

.4 gallons/hour

(1.5 liters/hour)

.8 gallons/hour

(3.1 liters/hour)

1.6 gallons/hour

(6.2 liters/hour)

1.8 gallons/hour

(7.0 liters/hour)

1.7 gallons/hour

(6.5 liters/hour)

1.8 gallons/hour

(7.0 liters/hour)

.4 gallons/hour

(1.5 liters/hour)

1.0 gallons/hour

(3.9 liters/hour)

1.5 gallons/hour

(5.7 liters/hour)

1.7 gallons/hour

(6.5 liters/hour)

1.6 gallons/hour

(6.2 liters/hour)

1.7 gallons/hour

(6.5 liters/hour)

Ranger 9 Approximate Fuel Consumption

STICK/TIG (constant current) 6 45,90,120,range settings 160,200,250

WIRE FEED (constant voltage) 3 LOW,MED,HIGHrange settings

CONTROL”“

Provides a fine welding current adjustment within theRange Switch settings in the STICK/TIG mode andwelding voltage control with the Range switch set inthe WIRE FEED mode.

-15 -

ON OFF

Explanation of Symbols that Appear on this Equipment

Low Idle High Idle

Never change the “POLARITY” switch settingwhile welding. This will damage the switch.------------------------------------------------------------------------

Never change the “RANGE” switch setting whilewelding. This will damage the switch.------------------------------------------------------------------------

CAUTION

CAUTION

RANGE” Switch“

Page 18: RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process

Starting/Shutdown InstructionsStarting the Engine

Be sure all Pre-Operation Maintenance has been per-formed. Also, read the Engine Owner’s Manual.

Remove all loads connected to the AC power recepta-cles. To start the engine, set the “Idler Control” switchin the Automatic ( / ) position.

Use the choke control as follows: Onan Engine - If the engine is cold, pull the chokecontrol out. Do not use the choke if the engine is warmor hot.

Kohler Engine - Always pull the choke control outwhen starting the engine; cold, warm or hot. Place the“Engine” switch in the “ON” position.

Push the “START” button and crank the engine until itstarts. Release the button as soon as the enginestarts. Do not push the “START” button while theengine is running because this will cause damage tothe ring gear and/or starter motor. After the enginehas started, slowly return the choke control to the full“in” position (choke open).

After running at high engine speed for 10-14 seconds,the engine will go to low idle.

Allow the engine to warm up by letting it run at low idlefor a few minutes.

“CONTROL AT WELDER /

The toggle switch on the control panel labeled“CONTROL AT WELDER” and “REMOTE CONTROL”gives the operator the option of controlling the outputat the welder control panel or at a remote station.Remote connections are made at the 6-pin or 14-pinamphenol connector.

For remote control, the toggle switch is set in the“REMOTE CONTROL” position.

For control at the welder control panel, the toggleswitch is set in the “CONTROL AT WELDER” position.

“WELDING TERMINALS” Switch

The toggle switch labeled “WELDING TERMINALSALWAYS ON” and “WELDING TERMINALSREMOTELY CONTROLLED” is used to control theoperation of the welder output contactor.

With the switch in the “ALWAYS ON” position, theoutput contactor is closed at LOW and HIGH idle.

With the switch in the “REMOTELY CONTROLLED”position, the contactor is open at LOW idle and HIGHidle until a control cable is attached to the welderamphenol connector from a wire feeder. Under thiscondition, contactor closes when the wire feedertrigger is depressed and opens when the trigger isreleased.

“IDLER” Switch

The idler switch has two positions, “HIGH” and“AUTO”.

When in “HIGH” position, the engine will runcontinuously at high idle.

When in “AUTO” / idle position, the idleroperates as follows:

a. WeldingLow idle and in the “WELDING TERMINALS ALWAYS ON” mode -Stick Welding only. When the electrode touches work, thewelding arc is initiated and the engine accelerates tofull speed.

Low idle and in the “WELDING TERMINALS REMOTELYCONTROLLED” mode -Wire Welding Only Pressing the guntrigger closes the Ranger 9 output contactor andcauses the engine to accelerate to full speed.

After the gun trigger is released and/or weldingceases (and no auxiliary power is being drawn), theengine will return to low idle after approximately 10 to14 seconds.

REMOTE CONTROL” Switch

-16 -

b. Auxiliary Power - With the engine running at lowidle and auxiliary power for lights or tools is drawn(approximately 100-150 watts or greater) from thereceptacles, the engine will accelerate to high speed.If no power is being drawn from the receptacles (andnot welding) for 10-14 seconds, the idler reduces theengine speed to low idle.

• Do not touch electrically live partsof electrode with skin or wetclothing.

• Keep flammable material away.

• Insulate yourself from work andground. Wear eye, ear, and bodyprotection.

• Keep your head out of the fumes.

• Use ventilation or exhaust to remove fumes from breathing zone.

WARNING

Page 19: RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process

Stopping the Engine

Remove all welding and auxiliary power loads andallow engine to run at low idle speed for a few minutesto cool the engine.

Stop the engine by placing the “Engine” switch in the“OFF” position.

A fuel shut off valve is not required on the Ranger 8because the fuel tank is mounted below the engine.

Break-in Period

It is normal for any engine to use a greater amount ofoil until the break-in is accomplished. Check the oillevel twice a day during the break-in period (approxi-mately 50 running hours)).

IMPORTANT: IN ORDER TO ACCOMPLISH THISBREAK-IN, THE UNIT SHOULD BE SUBJECTED TOMODERATE LOADS, WITHIN THE RATING OF THEMACHINE. AVOID LONG IDLE RUNNING PERIODS.REMOVE LOADS AND ALLOW ENGINE TO COOLBEFORE SHUTDOWN.

The engine manufacturer’s recommendation for therunning time until the first oil change is as follows:

The oil filter is to be changed at the second oil change.Refer to the Engine Owner’s Manual for more informa-tion.

Welding Processes

Stick (Constant Current) Welding

Connect welding cables to the “TO WORK” and“ELECTRODE” studs. Start the engine. Set the"POLARITY” switch to the desired polarity. Set theoutput “CONTROL” or remote output control to max(10) and the “RANGE” switch to the setting that isclosest to the recommended current for the electrodebeing used and make a trial weld. A fine adjustmentof the welding can be made by adjusting the output“CONTROL” or remote control. For the best arcstability, always use setting that results in the highestsetting of the output or remote control and the lowestsetting of the “RANGE” switch.

The Ranger 9 can be used with a broad range of ACand DC stick electrodes. See “Welding Tips 1”included with the Ranger 9 for electrodes within therating of this unit and recommended welding currentsof each. See the following table for welding currentranges:

CURRENT RANGES (AC and DC STICK WELDING- 5 to 10 ON CONTROL DIAL)

TIG (Constant Current) Welding

The Ranger 9 can be used in a wide variety of ACand DC Tungsten Inert Gas (TIG) welding applicationsfor AC TIG welding up to 200 amps and DC TIGwelding up to 250 amps.

The K930-1 TIG Module installed on a Ranger 9provides high frequency and shielding gas control forAC and DC GTAW (TIG) welding processes. The TIGModule allows full range output control. Afterflow timeis adjustable from 0 to 55 seconds.

When using the Ranger 9 for AC TIG welding ofaluminum, the TIG Module is to be set for CONTINU-OUS HF. The following settings and electrodes arerecommended:

When AC TIG welding, the actual maximum weldingcurrent is 40 to 80 amps higher than the currentmarked on the RANGE SWITCH dial. This is a resultof a lower effective reactance due to the natural rectifi-cation that occurs with the AC TIG welding process.

Wire Feed (Constant Voltage) Welding

The Ranger 9 can be used with a broad range of flux-cored wire (Innershield and Outershield) electrodesand solid wires for MIG welding (gas metal arcwelding).

Some recommended Innershield electrodes are:NR-211MP, NR-311, NR-203 series as well as,Lincore® 33 and 55 hardfacing electrodes. Diametersfrom .035 (0.9mm) up to and including 5/64” (2.0mm)can be used. 5/64” (2.0mm) NS-3M can be used inlimited applications. Cable length and other condi-tions can affect the ultimate results of this application.Request Lincoln publication N-675 for additional infor-mation.

-17 -

Pure (EWP)Tungsten Diameter

“Range”Switch Settings

WeldingCurrent

1/8

3/32

1/16

90, 120

45, 90

45, 90

100 to 200 amps

45 to 140 amps

45 to 100 amps

RANGE SETTINGON MACHINE

ACTUALCURRENT RANGE

4590120160200250

25 to 45 AMPS50 to 90 AMPS60 to 120 AMPS80 to 160 AMPS100 to 200 AMPS140 to 250 AMPS

KohlerCH20S

5 hr

OnanP218

25 hr

Page 20: RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process

SUMMARY OF WELDING PROCESS

-18 -

CONTROLCABLEUSED

IDLEMODE

OUTPUTCONTROLSWITCH

WELDINGTERMINALS

SWITCH

ELECTRODEWHEN NOTWELDING TO START WELDINGPROCESS

STICK - CC

TIG - CCK930-1/K936-1(WITH AMPTROL)

WIRE FEED - CV,LN-25 WITH 42VREMOTE CON-TROL KIT

WIRE FEED - CV,LN-25 WITHINTERNALCONTACTOR

WIRE FEED - CV,LN-742

WIRE FEED - CV,LN-7

Touch electrode to work.Welding starts immediatelyand engine goes to high idle.

Press Amptrol. Weldingstarts immediately.

Press gun trigger, Ranger 9contactor closes. Weldingstarts immediately and enginegoes to high idle.

Press gun trigger, LN-25contactor closes. Weldingstarts immediately and enginegoes to high idle.

Press gun trigger, Ranger 9contactor closes. Weldingstarts immediately and enginegoes to high idle.

Press gun trigger, Ranger 9contactor closes. Weldingstarts immediately.

NO

YES

YES

NO

YES

YES

AUTO

AUTO

AUTO

AUTO

AUTO

HIGH

ATWELDER

REMOTE

REMOTE

ATWELDER

REMOTE

REMOTE

ALWAYSON

REMOTE

REMOTE

ALWAYSON

REMOTE

REMOTE

HOT

COLD

COLD

COLD

COLD

COLD

Recommended Outershield electrodes are: .045(1.1mm), .052 (1.3mm) and 1/16 (1.6mm) Outershield71 and 1/16” (1.16mm) Outershield 70. RequestLincoln publication GS-200 for additional information.

Some recommended solid wires for MIG welding are:.030 (0.8mm), .035 (0.9mm) and .045 (1.1mm) L-50and L-56. Request Lincoln publication GS-100 foradditional information.

When using a wire feeder with contactor control, theelectrode will be “cold” until the gun trigger is pressed.To start the welding process, position the gun andclose the gun trigger. The contactor will close, the arcwill be initiated and the engine will accelerate to fullspeed. To stop welding, release the gun trigger andpull the gun away from the work. With the “IDLERSWITCH” in the “AUTO” position, the engine will goback to low idle in approximately 12 seconds (whenno auxiliary power is drawn).

NOTE: The LN-7 and the LN-8 must be operated inthe “HIGH” idle position.

Page 21: RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process

-19 -

Auxiliary Power

The Ranger 9 can provide up to 9,000 watts of115/230 volts AC, single phase 60HZ power for contin-uous use. The front of the machine includes threereceptacles for connecting AC power plugs. TheK1420-1 has one 50 amp 115/230 volt NEMA 14-50R receptacle and two 20 amp 115 volt NEMA 5-20R receptacles. The K1420-2 CSA machine has one50 amp 115/230 volt NEMA 14-50R receptacle andtwo 15 amp 115 volt NEMA 5-15R receptacles. Donot connect any plugs that connect to the powerreceptacles in parallel.

Start the engine and set the “IDLER” control switch tothe desired operating mode. Set the “CONTROL” to10. Voltage is now correct at the receptalces forauxiliary power.

115/230 Volt Dual Voltage Receptacle

The 115/230 volt receptacle can supply up to 40 ampsof 230 volt power to a two wire circuit, up to 40 ampsof 115 volt power from each side of a three wire circuit(up to 80 amps total). Do not connect the 115 voltcircuits in parallel. Current sensing for the automaticidle feature is only in the leg of the three wire circuit asshown below.

Maximum Current Draw from 115V DuplexReceptacles - No Welding

Maximum Current Draw from Optional 115VGFCI Duplex Receptacles - No Welding

EACHHALF OF

EACH 115VDUPLEX

TOTALFROM

BOTH 115VDUPLEXES

EACHHALF OF

EACH 115VDUPLEX

TOTALFROM

BOTH 115VDUPLEXES

K1420-1 K1420-2 (CSA)and K1421-1 (CSA)

LOAD FROM115V / 230V

DUAL VOLTAGERECEPTACLE

0

2.2 KW

4.5 KW

6.7 KW

9.0 KW

20 *

20 *

20 *

20 *

0

78

60

40

20

0

15

15

15

15

0

60

60

40

20

0

EACHHALF OF

EACH 115VDUPLEX

TOTALFROM

BOTH 115VDUPLEXES

EACHHALF OF

EACH 115VDUPLEX

TOTALFROM

BOTH 115VDUPLEXES

K1420-1*(WITH GFCI’S)

K1420-2** andK1421-1**

(WITH GFCI’S)

LOAD FROM115V / 230V

DUAL VOLTAGERECEPTACLE

0

2.2 KW

4.5 KW

6.7 KW

9.0 KW

15

15

15

15

0

40

40

40

20

0

15

15

15

15

0

30

30

30

20

0

* Maximum current draw from each 115V GFCI Duplex is 20 amps.** Maximum current draw from each 115V GFCI Duplex is 15 amps.

* NEMA 5-20P plug required for 20 amp draw.

115V Duplex Receptacles

The 115V auxiliary power receptacles should only beused with three wire grounding type plugs or approveddouble insulated tools with two wire plugs.

GND

115 V

115 V

230 V

* Current Sensing for Automatic Idle(Receptacle viewed from front of machine.)

*

Page 22: RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process

Most 1.5 HP motors can be started if there is no loadon the motor or other load connected to the machine,since the full load current rating of a 1.5HP motor isapproximately 20 amperes (10 amperes for 230 voltmotors). The motor may be run at full load whenplugged into only one side of the duplex receptacle.Larger motors through 2HP can be run provided thereceptacle rating as previously stated is not exceeded.This may necessitate 230V operation only.

It must be noted that the above auxiliary power ratingsare with no welding load. Simultaneous welding andpower loads are permitted by the following table. Thepermissible currents shown assume that current isbeing drawn from either the 115 volt or 230 volt supply(not both at the same time).

NOTE: Voltage and permissible watts decrease as “CONTROL” is adjusted to settings less than 10. It is recommended that at settings less than 10, only incandescent lighting loads be connected to the auxiliary power receptacles.

OutputSelectorSetting

WeldingOutput

PermissiblePower Watts(Unity Power

Factor)

PermissibleAuxiliary Current in

Amperes @ 115V

PermissibleAuxiliary Current in

Amperes @ 230V

11162226

32.5

21.532.5

2028

526

2232445265

4365

4056

1052

NONE25003700500060007500

50007500

27506500

12006000

2502001601209045

20060

25080

250100

2502001601209045

CV LOW

CV MEDIUM

CV HIGH

Standby Power Connections

The Ranger 9 is suitable for temporary, standby oremergency power using the engine manufacturer'srecommended maintenance schedule.

The Ranger 9 can be permanently installed as astandby power unit for 230 volt, 3-wire, 40 ampereservice. Connections must be made by a licensedelectrician who can determine how the 115/230 voltpower can be adapted to the particular installation andcomply with all applicable electrical codes. Thefollowing information can be used as a guide by theelectrician for most applications (refer also to thePremises Wiring diagram shown).

IMPORTANT: When the Ranger 9 is connected to a 230 volt, 3-wire line, the unit should be operatedwith the idler switch in the “HIGH” idle position to avoidload sensing problems. If the machine is set forautomatic idle, the 230 volt circuit will sense loads andcause the engine to accelerate to high idle. However, since only one line of the circuit senses current, 115volt power drawn from only one line to neutral mayresult in the engine not going to high idle.

1. Install the double pole, double throw switchbetween the power company meter and thepremises disconnect.

Switch rating must be the same or greater than the customer’s premises disconnect and service overcurrent protection.

-20 -MAR 95

Page 23: RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process

2. Take necessary steps to assure load is limited to the capacity of the Ranger 9 byinstalling a 40 amp, 230 volt double polecircuit breaker. Maximum rated load for eachleg of the 230 volt auxiliary is 40 amperes. Loading above 40 amps will reduce outputvoltage below the allowable - 10% of ratedvoltage which may damage appliances or other motor-driven equipment.

3. Install a 50 amp 115/230 volt plug (NEMAType 14-50) to the Double Pole CircuitBreaker using No. 8, 4 connector cable ofthe desired length. (The 50 amp 115/230 voltplug is available in the optional plug kit).

4. Plug this cable into the 50 amp 115/230 voltreceptacle on the Ranger 9 case front.

CONNECTION OF RANGER 9 TO PREMISES WIRING

-21 -

230 Volt60 Hz.3-WireService

POWER

COMPANY

METER

230 VOLT

115 VOLT

115 VOLT

LOADN

NEUTRALBUS

GROUND

PREMISESDISCONNECT AND

SERVICEOVERCURRENT

PROTECTION

GND

N

NOTE: No. 8 COPPER CONDUCTOR CABLE SEENATIONAL ELECTRICAL CODE FOR ALTERNATE WIRE

SIZE RECOMMENDATIONS.

230 VOLT

GROUNDED CONDUCTOR

40 AMP230 VOLT

DOUBLEPOLE

CIRCUITBREAKER

DOUBLE POLE DOUBLE THROWSWITCH RATING TO BE THE SAMEAS OR GREATER THAN PREMISESSERVICE OVERCURRENTPROTECTION.

50 AMP, 115/230VOLT PLUG

NEMA TYPE 14-50

50 AMP, 115/230 VOLTRECEPTACLE

Page 24: RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process

MAINTENANCESafety Precautions

-22 -

Have qualified personnel do the maintenancework. Turn the engine off before working insidethe machine. In some cases, it may benecessary to remove safety guards to performrequired maintenance. Remove guards onlywhen necessary and replace them when themaintenance requiring their removal iscomplete. Always use the greatest care whenworking near moving parts.

Do not put your hands near the engine coolingblower fan. If a problem cannot be corrected byfollowing the instructions, take the machine tothe nearest Lincoln Field Service Shop.

-----------------------------------------------------------------------ELECTRIC SHOCK can kill.• Do not touch electrically live parts or

electrode with skin or wet clothing.• Insulate yourself from work and

ground• Always wear dry insulating gloves.

------------------------------------------------------------------------ENGINE EXHAUST can kill.• Use in open, well ventilated areas or

vent exhaust outside.

------------------------------------------------------------------------MOVING PARTS can injure.• Do not operate with doors open or

guards off.• Stop engine before servicing.• Keep away from moving parts.

------------------------------------------------------------------------

See additional warning information atfront of this operator’s manual.

-----------------------------------------------------------

WARNING

Engine Adjustments

OVERSPEED IS HAZARDOUSThe maximum allowable high idle speed for thismachine is 3750 RPM, no load. Do NOT tamperwith governor components or setting or make anyother adjustments to increase the maximumspeed. Severe personal injury and damage to themachine can result if operated at speeds abovemaximum.------------------------------------------------------------------------Adjustments to the engine are to be made only by aLincoln Service Center or an authorized Field ServiceShop.

WARNING

Routine Maintenance1. At the end of each day’s use, refill the fuel tank to

minimize moisture condensation in the tank.Running out of fuel tends to draw dirt into the fuelsystem. Also, check the crankcase oil level andadd oil if indicated.

2. OIL - Maintenance schedule for changing the oiland oil filter after break-in:

The above schedule is for normal operating condi-tions. More frequent oil changes are required withdusty, high temperature, and other severe operatingconditions. Refer to the maintenance section of theEngine Owner’s Manual for more information.

Engine life will be reduced if the oil and oil filterare not changed according to the manufacturer’srecommendation.-----------------------------------------------------------------------3. Air Cleaner - With normal operating conditions, the

maintenance schedule for cleaning and re-oilingthe foam pre-filter is every 25 hours and replace-ment of the air cleaner filter every 100 hours. Morefrequent servicing is required with dusty operatingconditions. Refer to maintenance section of theEngine Owner’s Manual for more information.

4. Refer to the maintenance section of the EngineOwner’s Manual for the maintenance schedule forspark plug servicing, cooling system servicing, andfuel filter replacement.

Make certain that the oil filler cap is securelytightened after checking or adding oil. If the cap isnot tight, oil consumption can increase signifi-cantly which may be evidenced by white smokecoming from the exhaust.------------------------------------------------------------------------5. Blow out the machine with low pressure air periodi-

cally. In particularly dirty locations, this may berequired once per week.

6. Output Ranger Selector and Polarity Switches:Switch contacts should not be greased. To keepcontacts clean, rotate the switch through its entirerange frequently. Good practice is to turn the han-dle from maximum to minimum setting twice eachmorning before starting to weld.

CAUTION

CAUTION

Oil

Oil Filter

KohlerCH20S

100 hr

200 hr

OnanP218

50 hr

100 hr

Page 25: RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process

Use correct polarity - Negative Ground.

To prevent BATTERY DISCHARGE, if you have an ignition switch, turn it off when engine is notrunning.

• To prevent BATTERY BUCKLING, tighten nuts on battery clamp until snug.

------------------------------------------------------------------------

1. When replacing, jumping or otherwiseconnecting the battery to the battery cables,the proper polarity must be observed. Failureto observe the proper polarity could result indamage to the charging circuit. The positive(+) battery cable has a red terminal cover.

2. If the battery requires charging from anexternal charger, disconnect the negativebattery cable first and then the positivebattery cable before attaching thecharger leads. Failure to do so can resultto damage to the internal chargercomponents. When re-connecting the cables, connect the positive cable first andthe negative cable last.

HARDWARE

Both English / Metric fasteners are used in thiswelder.

-23 -

GASES FROM BATTERY can explode.• Keep sparks, flame and cigarettes

away.

BATTERY ACID can burn eyes andskin.

• Wear gloves and eye protection and becareful when boosting, charging orworking near battery.

To prevent EXPLOSION when:a) Installing a new battery - disconnect the

negative cable from the old battery first and connect the negative cable to the new battery last.

b) Connecting a battery charger - remove the battery from the welder by disconnecting the negative cable first, then the positive cable and battery clamp. When reinstalling, connect the negative cable last.

c) Using a booster - connect the positive lead to the battery first, then connect the negative lead to the ground lead on the base.

To prevent ELECTRICAL DAMAGE when:a) Installing a new battery.b) Using a booster.

WARNING

Battery Charging

ONAN P218 KOHLER CH20S

Oil Filter ONAN 122-0645 KOHLER 1205001FRAM PH3614 FRAM PH3614*

Air Filter ONAN 140-2628-01 KOHLER 4708303Element FRAM CA140PL FRAM CA79

Air Filter ONAN 140-1496 KOHLER 2408302Pre-Cleaner

Fuel Filter ONAN 149-2005 KOHLER 2505002FRAM G1 FRAM G1

Spark Plugs ONAN 167-0263 CHAMPION RC12YC(Resistor CHAMPION RS14YC (.030” GAP)

Type) (.025” GAP)

* Oil capacity increases from 2.0 Qts. to 2.1 Qts. when using this filter.

Engine Maintenance Parts

Page 26: RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process

TROUBLESHOOTING

ENGINE

TROUBLE

A. Engine will not crank or is hard tocrank.

B. Engine will not start or shuts down.

C. Engine does not develop fullpower.

D. Battery does not stay charged.

CAUSE

1. Battery will not hold a charge. Faulty battery.

2. No or insufficient charging current.

3. Loose battery cable connection(s).

4. Lead #216A from solenoid to startswitch broken.

5. Spark plugs fouled.

1. Low oil pressure.2. Out of fuel.3. Fault in fuel system.4. #216 lead from start switch to P.C.

board broke / (Onan engine).5. Oil pressure switch faulty.6. Generator terminal block connection

faulty.7. Faulty P.C. Board (Onan engine).

1. Fuel filter clogged.2. Air filter clogged.

1. Faulty battery.2. Faulty charging system.

3. Loose or broken lead in charging circuit.

WHAT TO DO

1. Replace with known good one.

2. Check connection of lead fromvoltage regulator on engine tocharging ammeter and batterylead #208 and #209.

3. Check and tighten connection atbattery, at starter, at engine foot,or at frame.

4. Repair.

5. Replace spark plugs.

1. Check oil level and add oil as req’d.2. Add fuel to tank.3. Repair.4. Repair.

5. Replace6. Repair. Check leads #208, 224A,

224B, 212.7. Replace.

1. Replace.2. Replace.

1. Replace with a new battery.2. Refer to Engine Operators Manual

for charging system service.3. Refer to wiring diagram and check

related leads, especially #208 and#209 leads.

-24 -

Page 27: RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process

IDLER SYSTEM

TROUBLE

A. Engine will not idle down to lowspeed.

B. Engine will not go to high idlewhen attempting to weld.

I. Scratch Start

II. When using wire feeder with con-trol cable plugged into amphenolconnector or using amptrol whentrigger is depressed.

C. Engine will not go to high idle when using auxiliary power.

CAUSE

1. Idler switch in “HIGH” idle position.2. External load on welder or auxiliary

power.3. Mechanical problem in idler solenoid

linkage.4. Idler solenoid position out of adjust-

ment.5. Faulty wiring in solenoid circuit.

6. Contactor circuit #2 or #4 closed orshorted. Engine goes to high idlewhen contactor circuit closes.

7. Faulty idler solenoid.8. Low voltage at 224D to ground stud.

(Voltage should be 12-14V DC).9. Faulty P.C. Board PCB1.

1. Poor work lead connection to work.

2. “WELDING TERMINALS” switch inwrong position.

3. No open circuit voltage on outputstuds.

4. Faulty P.C. Board PCB1.

1. “WELDING TERMINALS” switch inwrong position.

2. Faulty wiring.

1. No signal from current sensor.

2. Auxiliary power lead less than 100watts.

3. Faulty idler P.C. Board

WHAT TO DO

1. Set switch to “AUTO” position.2. Remove all external loads.

3. Repair.

4. Adjust solenoid as necessary.

5. Check for broken leads #224D,214.

6. Refer to wiring diagram. Checkrelated leads and amphenolconnectors.

7. Replace with known good one.8. Check wiring, battery and battery

charging circuits.9. Replace P.C. Board with known

good one.

1. Make sure work clamp is tightlyconnected to clean base metal.

2. Switch must be in “ALWAYS ON”position to scratch start.

3. Check leads #247 and #250 forbreaks. Check Switch S6 for faults.

4. Replace P.C. Board with known good one.

1. Switch must be in “REMOTELYCONTROLLED” position.

2. Refer to schematic. Check wiringin #2 and #4 circuit.

1. Check for broken leads in idlersensing circuit. #3 lead.

2. Idler may not respond with less than 100 watt load. Set idlerswitch to high idle.

3. Replace P.C. Board with knowngood one.

-25 -

Page 28: RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process

OUTPUT SYSTEM

TROUBLE

A. No welder or power output.

B. Output control on welder notfunctioning.

C. Output control or remote notfunctioning.

D. Wire feeder does not work whenconnected to welder amphenol.

CAUSE

1. Open lead in flashing or field circuit.

2. Faulty rotor.

3. Faulty stator field.

4. Faulty field rectifier D2.5. Output contactor does not pull in.

6. Faulty P.C. Board.

1. Output control switch in wrongposition.

2. Output control switch defective.3. Output control potentiometer

defective.4. Faulty wiring.

5. Faulty P.C. Board

1. Output control switch in wrongposition.

2. Leads #75, #76, #77 broken at P.C.Board or S4.

3. Leads #75A, #76A, #77A broken atS4 or amphenol.

4. Remote control leads broken incontrol cable.

5. Faulty wire feeder.

6. Faulty P.C. Board.

1. Wire feeder circuit breaker open orfaulty.

2. Broken #31, #32, or #42 lead at amphenol.

3. No 115V or 42V output from stator.

4. Faulty wiring in control cable.5. Faulty wire feeder.

WHAT TO DO

1. Refer to wiring diagram and checkrelated leads. (#7 & #9; #200, #201 and #219)

2. Lift brushes and check rotorcontinuity between slip rings.(Should be approx. 7.3Ω)

3. Disconnect lead #7 at D2 andcheck for continuity betweenleads #7 and #9.

4. Replace with known good one.5. Refer to wiring diagram and check

related leads and contactor.6. Replace P.C. Board with known

good one.

1. Place switch in “Output Controlat Welder”.

2. Check and replace switch if faulty.3. Check and replace potentiometer

if faulty.4. Check for broken leads #75, #76,

and #77 from P.C. Board and #75A, #76D, and #77D frompotentiometer to remote switch.

5. Replace P.C. Board with known good one.

1. Place switch in “Remote” position.

2. Repair.

3. Repair.

4. Repair.

5. Replace wire feeder with knowngood one.

6. Replace P.C. Board with knowngood one.

1. Reset or replace.

2. Repair.

3. Check continuity on #31, #32, and#42 at stator. Check buildup. IfO.K. , stator may be faulty.Replace.

4. Repair or replace cable.5. Replace P.C. Board with known

good one.

-26 -

Page 29: RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process

OUTPUT SYSTEM

TROUBLE

E. Contactor does not pull in when scratch starting when engine goes to high idle.

F. Contactor does not pull in whenusing a wire feeder with a controlcable plugged into amphenol.

G. Contactor does not drop out.

CAUSE

1. Welding terminal switch in wrongposition.

2. Faulty wiring in contactor circuit.

3. Faulty remote switch S6.

4. Faulty contactor.

5. Faulty P.C. Board PCB1.

1. “WELDING TERMINALS” switchin wrong position.

2. Faulty wiring in contactor circuit.

3. Faulty amphenol or bypass P.C.Board PCB2.

4. Faulty contactor.

5. Faulty P.C. Board PCB1.

6. Faulty control cable from wirefeeder or amphenol.

7. Faulty wire feeder.

1. Faulty wiring.

2. Faulty amphenol or bypass P.C.Board PCB2.

3. Faulty contactor.4. Faulty P.C. Board PCB1.

WHAT TO DO

1. Place switch S6 in “Always On”position.

2. Check for broken leads #224C,#232A, and #224.

3. Check switch and leads #247,and #250.

4. Replace contactor with knowngood one.

5. Replace P.C. Board with knowngood one.

1. Place switch S6 in “REMOTELYCONTROLLED” position.

2. Check for broken leads #224,#224C & #232A.

3. Refer to wiring diagram and check related leads (#2 and #4).

4. Replace contactor with knowngood one.

5. Replace P.C. Board with knowngood one.

6. Replace.

7. Repair or replace.

1. Check that lead #232 is notgrounded.

2. Look for shorts to ground. Repairor replace.

3. Replace with known good one.4. Replace with known good one.

-27 -

Page 30: RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process

-28 -

236

ELEC

TROD

EW

OR

K

241

GN

D

(+)

D1

(-)

R1

C2

25W

100

C3

C4

C5

224E

AM

MET

ER

209

AM

1

AU

TO

HIG

H

35

6

212

CA

PA

CIT

OR

AC

AC

B+

208

STA

RTE

R

REG

ULA

TOR

(+)

(-)

200A

219

200

SR

(+)

(-)

RO

TOR

FIE

LD(+)

(-)

(+) (-)

C1

800

MFD

CV-

CV+

DC

+ DC

-

AC

212

(CAV

ITY

#1)

208

(CA

VITY

#3)

+-

+ -

D2(-

)

(+)

CR1

209

AC

AC

LOC

ATI

NG

3132

429

7

PC

BO

AR

DP

CB

1

1

61

2

1

J1J2

4

58

CURR

ENT

SENS

OR

75A

AM

PH

ENO

L 2

14

58

1 13

46

2

34

J3

J4J5

31B

4232 21

5E GR

OU

ND

SC

REW

PCB2

BYPA

SS P

C

76

10K

PO

TR3

75A

CW

MA

X

ENGI

NEHO

UR M

ETER

115

V

5K

115

V

J6 J7

9

201A

200B

SH

OW

N IN

PO

SIT

ION

+ -

IDLE

R

SO

LEN

OID

12V

CO

NTA

CTO

RA

ND

219

3 TU

RNS

232

254A

235

21

2C75

A

5E3

76A

77A

31A

63A 55L

5L

3B

WHITE

WHITE

WHITE

BLACK BLACK

BLACK

GR

EEN

BLA

CK

6

3B

5K

77A

76A

5E

7

3 3 5A 5F3

76D

77D

76D

76A

77A

224

200B

224C 5A 21

9

224E

76

224D

208A

254A 25

4 3 3 77

235

242

236

232

216A

224A

224B

5F

240 75

200B

232A 21

6

201A21

4

75

3

77

214

201A

216

219

232A

5A

224C

77

2C2A 4A77C

76C

75C

2B75B

77B

76B

4B

4B2B75B

76B

77B

75C

76C

77C

2A4A

(J)

(A)

(D)

(C)

(H)

(E)

(F)

(G)

(I) (K)

(B)

(A)

(B)

(C)

(D)

(E)

(F)

GN

D-C

GN

D-G

115V

AC

CO

NTA

CTO

R

WO

RK

REM

OTE

CO

NTR

OL

42VA

C

GR

OU

ND

REM

OTE

CO

NTR

OL

CO

NTA

CTO

R

GR

OU

ND

GN

D-B

GN

D-A

77A

76A

4C

4C

250

50W

R2

242

S6

L2

CB

1

SO

LEN

OID

216A

S4

212

250

1 32 4

7

2C

2C

240

224A

&B (C

AVI

TY #

4)

232

254

247

C1

W1W

2

C2C3

R1

R2

R3R

4R

5R

6C

1C2 C

3

S2

REA

CTO

RE

S1

STA

TOR

SH

OW

N IN

"HIG

H'

PO

SIT

ION

5C

5B

208

5C

5D

31A

224B

(CAV

ITY

#2)

232A 20

0B

GN

D-G

232A

"ALW

AYS

ON

" 24

7

208B

5B

5D

201

201

BET

WEE

N A

MP

HEN

OL

HO

LES

ON

5

224C22

4E 224

236A

236A

245

7-1

9-96

G

L1

0248

STA

RTE

R M

OTO

R

NO

TE

S:

31,0

00 M

FDC

AP

AC

ITO

RS

SLI

PR

ING

SW

ELD

ER L

EAD

EN

D(N

OTE

CA

VITY

NU

MB

ERS

)

REM

OTE

SW

ITC

H(S

HO

WN

INR

EMO

TE P

OS

ITIO

N)

IN L

INE

CO

NN

ECTO

RS

(3 P

LAC

ES)

S1

ELEC

TRO

DE

PO

LAR

ITY

SW

ITC

H

OU

TPU

TC

ON

TAC

TOR

L1(C

HO

KE)

OU

TPU

TR

ECTI

FIER

S5

IDLE

RS

WIT

CH

AM

PH

ENO

L 1

125/

250V

. S

ING

LER

ECEP

TAC

LE

GROU

ND S

CREW

BLOW

ER B

AFFL

E

OU

TPU

TR

HEO

STA

T

OIL

PR

ESS

UR

ES

WIT

CH

TO S

PA

RK

PLU

GS

SLI

P R

ING

NEA

RES

T LA

MIN

ATI

ON

FLYW

HEE

LA

LTER

NA

TOR

ENG

INE

FOO

TEN

GIN

EC

RO

SS

SU

PP

OR

T

GN

D-H

B-

WEL

DIN

G T

ERM

INA

LC

ON

TRO

L S

WIT

CH

25 O

HM24

0

GN

D-E

242

GR

EEN

GN

D-D

GN

D-C

GN

D-E

GN

D-D

GR

EEN

VOLT

AG

E

IGN

ITIO

NC

OIL

IGN

ITIO

NM

OD

ULE

DIA

GR

AM

"A

"E

NG

INE

TE

RM

INA

LB

LO

CK

CO

NN

EC

TIO

N

SEE

DIA

GR

AM

"A

" FO

REN

GIN

E TE

RM

INA

LB

LOC

K C

ON

NEC

TIO

N.

IDLE

R

S2A

(CLO

SED

WIT

H S

2 IN

C1,

C2

OR

C3

PO

SIT

ION

)

RA

NG

ES

WIT

CH

S2

(10A

MP

)

TAB

CO

LOR

EDS

ILVE

R

TER

MIN

ALS

CO

LOR

EDS

ILVE

R

TER

MIN

ALS

CO

LOR

EDS

ILVE

R

TER

MIN

ALS

RA

NG

ER

9 (

ON

AN

) -

WIR

ING

DIA

GR

AM

- C

OD

E 1

03

78

& 1

05

39

EL

EC

TR

ICA

L S

YM

BO

LS

PE

R E

1537

AL

L C

AS

E F

RO

NT

CO

MP

ON

EN

TS

VIE

WE

D F

RO

M R

EA

R.

PO

SIT

ION

"S3"

SH

OW

NIN

"R

UN

"

S7 STA

RT

BU

TTO

N

NO

TE

: T

his

dia

gra

m is

fo

r re

fere

nce

onl

y.

It m

ay n

ot

be

accu

rate

fo

r al

l mac

hine

s co

vere

d b

y th

is m

anua

l. T

he s

pec

ific

dia

gra

m f

or

a p

artic

ular

co

de

is p

aste

din

sid

e th

e m

achi

ne o

n o

ne o

f th

e en

clo

sure

pan

els.

If

the

dia

gra

m is

ille

gib

le, w

rite

to

the

Ser

vice

Dep

artm

ent

for

a re

pla

cem

ent.

G

ive

the

equi

pm

ent

cod

e nu

mb

er..

Page 31: RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process

-29 -

236

ELEC

TROD

EW

OR

K

241

GN

D

(+)

D1

(-)

R1

C2

25W

100

C3

C4

C5

224E

AM

MET

ER

209

AM

1

AU

TO

HIG

H

35

6

212

CA

PA

CIT

OR

AC

AC

B+

208

STA

RTE

R

REG

ULA

TOR

(+)

(-)

CV-

CV+

DC

+ DC

-

AC

212

(CAV

ITY

#1)

208

(CA

VITY

#3)

+-

+ -

CR1

209

LOC

ATI

NG

3132

429

7

PC

BO

AR

DP

CB

1

1

61

2

1

J1J2

4

58

CU

RR

ENT

SEN

SOR

75A

AM

PH

ENO

L 2

14

58

1 13

46

2

34

J3

J4J5

31B

4232 21

5E GR

OU

ND

SC

REW

PCB2

BYPA

SS P

C

76

10K

PO

TR3

75A

CW

MA

X

ENGI

NEHO

UR M

ETER

SH

OW

N IN

PO

SIT

ION

+ -

IDLE

R

SO

LEN

OID

12V

CO

NTA

CTO

RA

ND

219

3 TU

RN

S

232

254A

235

21

2C75

A76

A77

A

31A

77A

76A

3 3 5A 5F3

76D

77D

76D

76A

77A

224

200B

224C 5A 21

9

224E

76

224D

208A

254A 25

4 3 3 77

235

242

236

232

216A

224A

224B

5F

240 75

200B

232A 21

6

201A

214

75

3

77

214

201A

216

219

232A

5A

224C

77

2C2A 4A77C

76C

75C

2B75B

77B

76B

4B

4B2B75B

76B

77B

75C

76C

77C

2A4A

115V

AC

CO

NTA

CTO

R

WO

RK

REM

OTE

CO

NTR

OL

42VA

C

GR

OU

ND

REM

OTE

CO

NTR

OL

CO

NTA

CTO

R

GR

OU

ND

GN

D-B

GN

D-A

4C

4C

250

50W

R2

242

S6

L2

CB

1

SO

LEN

OID

S4

250

1 32 4

7

2C

2C

240

224A

&B (C

AVI

TY #

4)

232

254

247

C1

W1W

2

C2C3

R1

R2

R3R

4R

5R

6C

1C2 C

3

S2

REA

CTO

RE

S1

STA

TOR

SH

OW

N IN

"HIG

H'

PO

SIT

ION

5C

5B

208

5C

5D

31A

224B

(CAV

ITY

#2)

232A

GN

D-D

232A

"ALW

AYS

ON

" 24

7

5B

5D

BET

WEE

N A

MP

HEN

OL

HO

LES

ON

224C22

4E 224

236A

236A

245

7-1

9-96

G

L1

0249

STA

RTE

R M

OTO

R

NO

TE

S:

31,0

00 M

FDC

AP

AC

ITO

RS

WEL

DER

LEA

D E

ND

(NO

TE C

AVI

TY N

UM

BER

S)

REM

OTE

SW

ITC

H(S

HO

WN

INR

EMO

TE P

OS

ITIO

N)

S1

ELEC

TRO

DE

PO

LAR

ITY

SW

ITC

H

OU

TPU

TC

ON

TAC

TOR

L1(C

HO

KE)

OU

TPU

TR

ECTI

FIER

S5

IDLE

RS

WIT

CH

AM

PH

ENO

L 1

GROU

ND S

CREW

BLOW

ER B

AFFL

E

OU

TPU

TR

HEO

STA

T

OIL

PR

ESS

UR

ES

WIT

CH

TO S

PA

RK

PLU

GS

FLYW

HEE

LA

LTER

NA

TOR

ENG

INE

FOO

TEN

GIN

EC

RO

SS

SU

PP

OR

T

GN

D-H

B-

WEL

DIN

G T

ERM

INA

LC

ON

TRO

L S

WIT

CH

25 O

HM24

0

GN

D-E

242

GN

D-E

VOLT

AG

E

IGN

ITIO

NC

OIL

IGN

ITIO

NM

OD

ULE

DIA

GR

AM

"A

"E

NG

INE

TE

RM

INA

LB

LO

CK

CO

NN

EC

TIO

N

SEE

DIA

GR

AM

"A

" FO

REN

GIN

E TE

RM

INA

LB

LOC

K C

ON

NEC

TIO

N.

IDLE

R

S2A

(CLO

SED

WIT

H S

2 IN

C1,

C2

OR

C3

PO

SIT

ION

)

RA

NG

ES

WIT

CH

S2

(10A

MP

)

200A

200

201

(+)

(-)

RO

TOR

FIE

LD

(+)

(-)

(+)

(-)

C1

800

MFD

D2 (+

)AC

AC

201

9

201A

200B

5E

7

77A

76A

115

V

SILV

ER

115/

230V

15A

CB6

15A

CB4

15A

15A

CB5

CB7

J6J8

5L5K

5

11

5K11

5 V

J73C

3D

GREEN

GREEN

GREEN

WHITE

BLACK

BLACK

GND-

G

GN

D-C

GND-

D

125/

250V

. SIN

GLE

RECE

PTAC

LE

GND-

C

GN

D-G

5E

IN L

INE

CO

NN

ECTO

RS

(3 P

LAC

ES)

5L

SLI

PR

ING

S

PO

SIT

IVE

SLI

PR

ING

NEA

RES

TLA

MIN

ATI

ON

5

3E

6

50A

CB2

50A

CB3

12

3D

WHITE

WH

ITE

WHITE

BLA

CK

BLACK

3A3B

3A3B

3C

BLACK

BLACK

BLACK

BLACK

11

BLA

CK

BLA

CK

BLACK

BLACK

BLACK

BLA

CK

BLA

CK

33E

HCDAJ E F G I K B A B C D E F

TERM

.CO

LORE

DSI

LVER

COLO

RED

TERM

INAL

S

SILV

ERCO

LORE

DTE

RMIN

ALS

TAB

RA

NG

ER

9 O

NA

N (C

SA V

ER

SIO

N) -

WIR

ING

DIA

GR

AM

- C

OD

E 1

0379

& 1

0540

EL

EC

TR

ICA

L S

YM

BO

LS

PE

R E

1537

AL

L C

AS

E F

RO

NT

CO

MP

ON

EN

TS

VIE

WE

D F

RO

M R

EA

R.

216A

212

208B

PO

SIT

ION

"S3"

SH

OW

NIN

"R

UN

"

S7 STA

RT

BU

TTO

N

NO

TE

: T

his

dia

gra

m is

fo

r re

fere

nce

onl

y.

It m

ay n

ot

be

accu

rate

fo

r al

l mac

hine

s co

vere

d b

y th

is m

anua

l. T

he s

pec

ific

dia

gra

m f

or

a p

artic

ular

co

de

is p

aste

din

sid

e th

e m

achi

ne o

n o

ne o

f th

e en

clo

sure

pan

els.

If

the

dia

gra

m is

ille

gib

le, w

rite

to

the

Ser

vice

Dep

artm

ent

for

a re

pla

cem

ent.

G

ive

the

equi

pm

ent

cod

e nu

mb

er..

Page 32: RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process

-30 -

236

ELEC

TROD

EW

OR

K

241

GN

D

(+)

D1

(-)

R1

C2

25W

100

C3

C4

C5

224E

AMM

ETER

209A

AM 1

AUTO

HIG

H

35

6

221

ACAC

B+

208

STAR

TER

REG

ULA

TOR

(+)

(-)

CV-

CV+

DC

+ DC

-

AC

221

(CAV

ITY

#1)

211

(CAV

ITY

#3)

+-

CR1

209A

LOC

ATIN

G

3132

429

7

PCB

OAR

DPC

B1

1

61

2

1

J1J2

4

58

CU

RR

ENT

SEN

SOR

75A

AM

PHEN

OL

2

14

58

1 13

46

2

34

J3J4J5

31B

4232 21

5E

PCB2

BYPA

SS P

C

76

10K

PO

TR3

75A

CW

MAX

ENGI

NEHO

UR M

ETER

SHO

WN

IN

POSI

TIO

N

+ -

IDLE

R

SOLE

NO

ID

12V

CO

NTA

CTO

RAN

D

219

3 TU

RN

S

232

254A

235

21

2C75

A76

A77

A

31A

77A

76A

3 3 5A 5F

3

76D

77D

76D

76A

77A

224

200B

224C

5A

219

224E

76

224D

208A

254A 25

4 3 3 77

235

242

236

232

224C21

1

5F

240 75

200B

232A

201A

214

75

3

77

214

201A

219

232A

5A

224C

77

2C2A 4A77C

76C

75C

2B75B

77B

76B

4B

4B2B75B

76B

77B

75C

76C

77C

2A4A

115V

AC

CO

NTA

CTO

R

WO

RK

REM

OTE

CO

NTR

OL

42VA

C

GR

OU

ND

REM

OTE

CO

NTR

OL

CO

NTA

CTO

R

GR

OU

ND

GN

D-B

GN

D-A

4C

4C

250

50W

R2

242

S6

L2

CB

1

SOLE

NO

IDS4

250

1 32 4

7

2C

2C

240

232

254

247

C1

W1W

2

C2C3

R1

R2

R3R

4R

5R

6C

1C2 C

3

S2

REA

CTO

RE

S1

STAT

OR

SHO

WN

IN"H

IGH

'PO

SITI

ON

5C

5B

208

5C

5D

31A

208

(CAV

ITY

#2)

232A

GN

D-D

232A

"ALW

AYS

ON

" 24

7

5B

5D

ON

224C22

4E 224

236A

236A

245

2-2

0-98

N

L1

0889

STA

RTE

R M

OTO

R

NO

TE

S:

31,0

00 M

FDC

APAC

ITO

RS

WEL

DER

LEA

D E

ND

(NO

TE C

AVIT

Y N

UM

BER

S)

REM

OTE

SW

ITC

H(S

HO

WN

INR

EMO

TE P

OSI

TIO

N)

S1 ELEC

TRO

DE

POLA

RIT

YSW

ITC

H

OU

TPU

TC

ON

TAC

TOR

L1 (CH

OK

E)

OU

TPU

TR

ECTI

FIER

S5ID

LER

SWIT

CH

AM

PHEN

OL

1

GROU

ND S

CREW

BLOW

ER B

AFFL

E

OU

TPU

TR

HEO

STAT

OIL

PR

ESSU

RE

SWIT

CH

FLYW

HEE

LAL

TER

NAT

OR

ENG

INE

FOO

TEN

GIN

EC

RO

SSSU

PPO

RT

GN

D-H

B-

WEL

DIN

G T

ERM

INAL

CO

NTR

OL

SWIT

CH

25 O

HM24

0

GN

D-E

242

GN

D-E

VOLT

AGE

IGN

ITIO

NM

OD

ULE

DIA

GR

AM

"A

"E

NG

INE

TE

RM

INA

LB

LO

CK

CO

NN

EC

TIO

N

SEE

DIA

GR

AM "

A" F

OR

ENG

INE

TER

MIN

ALB

LOC

K C

ON

NEC

TIO

N.

IDLE

R

S2A

(CLO

SED

WIT

H S

2 IN

C1,

C2

OR

C3

POSI

TIO

N)

RAN

GE

SWIT

CH

S2

(10A

MP)

200A

200

201

(+)

(-)

RO

TOR

FIE

LD

(+)

(-)

(+) (-)

C1

800

MFD

D2 (+

)ACAC

201

9

201A

200B

5E

7

77A

76A

115

V

SILV

ER

115/

230V

15A

CB6

15A

CB4

15A

15A

CB5

CB7

J6J8

5L5K

5

11

5K11

5 V

J73C

3D

GREEN

GREEN

GREEN

WHITE

BLACK

BLACK

GND-

G

GN

D-C

GND-

D

125/

250V

. SIN

GLE

RECE

PTAC

LE

GND-

C

GN

D-G

5E

IN L

INE

CO

NN

ECTO

RS

(3 P

LAC

ES)

5L

SLI

PR

ING

S

PO

SIT

IVE

SLI

PR

ING

NEA

RES

TLA

MIN

ATI

ON

5

3E

6

50A

CB2

50A

CB3

12

3D

WHITE

WH

ITE

BLA

CK

BLACK

3A3B

3A3B

3C

BLACK

BLACK

BLACK

BLACK

11

BLA

CK

BLA

CK

BLACK

BLACK

BLACK

BLA

CK

BLA

CK

33E

HCDAJ E F G I K B A B C D E F

TERM

.CO

LORE

DSI

LVER

COLO

RED

TERM

INAL

S

SILV

ERCO

LORE

DTE

RMIN

ALS

TAB

EL

EC

TR

ICA

L S

YM

BO

LS

PE

R E

1537

AL

L C

AS

E F

RO

NT

CO

MP

ON

EN

TS

VIE

WE

D F

RO

M R

EA

R.

210

208B

POSI

TIO

N

"S3"

SH

OW

NIN

"R

UN

"

S7 STAR

TB

UTT

ON

GR

OU

ND

SC

REW

BET

WEE

NAM

PHEN

OL

HO

LES

224C

(CAV

ITY

#4)

V

211

221

5H

5H

210

224C

W

U

R R

FUEL

SHU

TOFF

SOL.

224A

224A

WHITE

RA

NG

ER

9 K

OH

LER

(CSA

VE

RSI

ON

) - W

IRIN

G D

IAG

RA

M -

CO

DE

105

50

NO

TE

: T

his

dia

gra

m is

fo

r re

fere

nce

onl

y.

It m

ay n

ot

be

accu

rate

fo

r al

l mac

hine

s co

vere

d b

y th

is m

anua

l. T

he s

pec

ific

dia

gra

m f

or

a p

artic

ular

co

de

is p

aste

din

sid

e th

e m

achi

ne o

n o

ne o

f th

e en

clo

sure

pan

els.

If

the

dia

gra

m is

ille

gib

le, w

rite

to

the

Ser

vice

Dep

artm

ent

for

a re

pla

cem

ent.

G

ive

the

equi

pm

ent

cod

e nu

mb

er..

Page 33: RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process

– 31 –

12 -16-93

M17090

ELECTRODE CABLE

LN-25WIRE FEEDER

REMOTE CONTROL

TO WORK ELECTRODE

N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION.

TO WORK

WORK CLIP LEAD

WARNINGDo not operate with panels open.Disconnect NEGATIVE (-) BATTERY LEADbefore servicing.Do not touch electrically live parts.

Keep guards in place.Keep away from moving parts.Only qualified personnel should install,useor service this equipment.

TO WORK

6 PINAMPHENOL

N.B. USE POLARITY SWITCH TO SET FOR DESIRED ELECTRODE POLARITY. POSITION THE OUTPUT SELECTOR SWITCH TO A CV POSITION. N.C. IF OPTIONAL REMOTE OUTPUT CONTROL IS USED, PLACE OUTPUT CONTROL SWITCH IN "OUTPUT CONTROL REMOTE" POSITION.

RANGER 9 / LN-25 ACROSS THE ARC CONNECTION DIAGRAM

14 PINAMPHENOL

N.D. WELDING TERMINALS SWITCH MUST BE PLACED IN "ALWAYS ON" POSITION.

OPTIONAL K444-1

12 -16-93

M17091

SPARE

82

81

42

41

31

32

2

4

21

GND

75

76

77

31

32

2

4

21

GNDK867 UNIVERSALADAPTER PLUG

75

76

77

GREEN

TO WORK ELECTRODE

TO WORK

14 P INAMPHENOL

CAUTION :

N.D.

N.E.

ELECTRODE CABLETO WIRE FEED UNIT

LN-7WIREFEEDER

K291 OR K404INPUT CABLE

K775 OPTIONALREMOTE CONTROL

N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION.

N.D. INSULATE EACH UNUSED LEAD INDIVIDUALLY.N.E. SPLICE LEADS AND INSULATE.

N.B. USE POLARITY SWITCH TO SET FOR DESIRED ELECTRODE POLARITY. POSITION THE OUTPUT SELECTOR SWITCH TO A CV POSITION. N.C. IF OPTIONAL REMOTE OUTPUT CONTROL IS USED, PLACE OUTPUT CONTROL SWITCH IN "OUTPUT CONTROL REMOTE" POSITION.

ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE

DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED INTHE ENGINE WELDER OPERATING MANUAL.

AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE

RANGER 9 / K867 / K775 / LN-7 CONNECTION DIAGRAM

PLACE WELDING TERMINALS SWITCH TO "REMOTELY CONTROLLED" POSITION.

N.F. PLACE IDLER SWITCH IN "HIGH" IDLE POSITION.

WARNINGDo not operate with panels open.Disconnect NEGATIVE (-) BATTERY LEADbefore servicing.Do not touch electrically live parts.

Keep guards in place.Keep away from moving parts.Only qualified personnel should install,useor service this equipment.

Page 34: RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process

– 32 –

12 -16-93

M17092

ELECTRODE CABLE

OPTIONAL K857REMOTE CONTROL

TO WORK ELECTRODE6 PINAMPHENOL

14 PINAMPHENOL

TO WORK

TO WIRE FEED UNIT

TO LN-7 INPUTCABLE PLUG

CAUTION :

ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE

DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED INTHE ENGINE WELDER OPERATING MANUAL.

N.B. WELDING CABLES MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTUREAPPLICATIONS. SEE OPERATING MANUAL.

N.A. USE POLARITY SWITCH TO SET FOR DESIRED ELECTRODE POLARITY. POSITION THE OUTPUT SELECTOR SWITCH TO A CV POSITION.

N.C. IF OPTIONAL REMOTE OUTPUT CONTROL IS USED, PLACE OUTPUT CONTROL SWITCH IN "OUTPUT CONTROL REMOTE" POSITIION.

AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE

RANGER 9 / LN-7 CONNECTION DIAGRAM

PLACE WELDING TERMINALS SWITCH TO "REMOTELY CONTROLLED" POSITION.

N.D. PLACE IDLER SWITCH IN "HIGH" IDLE POSITION.

K584-XX INPUT CABLE ASSEMBLY

WARNINGDo not operate with panels open.Disconnect NEGATIVE (-) BATTERY LEADbefore servicing.Do not touch electrically live parts.

Keep guards in place.Keep away from moving parts.Only qualified personnel should install,useor service this equipment.

12 -16-93

M17093

N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION.

N.C. INSULATE EACH UNUSED LEAD INDIVIDUALLY.

N.C.

76

8281

SPARE2441423132

GND21

77

75REMOTE OUTPUT CONTROL

N.D.

2

4

10K

MIN.

NOT USED ON RANGER POWER SOURCES

42 VAC

115 VACN.E.

POWER SOURCE FRAME CONNECTION

N.D. FOR WIRE FEEDERS THAT RETURN A SIGNAL FOR WELDING OUTPUT, USE ISOLATION RELAY TO CLOSE LEADS 2 & 4.

K867 UNIVERSALADAPTER PLUG

14 PINAMPHENOL

{

TO WORK ELECTRODE

TO WORK

N.E. REFER TO POWER SOURCE INSTRUCTION MANUAL FOR MAXIMUM AUXILIARY CURRENT DRAW.

CAUTION :

N.B. USE POLARITY SWITCH TO SET DESIRED POLARITY, POSITION THE OUTPUT SELECTOR SWITCH TO A CV POSITION.

CONNECT TOGETHER FOR

WELDING OUTPUT

WIRE FEEDER VOLTMETER CONNECTIONCONNECTS TO (WORK TERMINAL) OF POWER SOURCEELECTRODE CABLE

TO WIRE FEED UNIT

TOWIREFEEDER

TOK867

ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE

DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED INTHE ENGINE WELDER OPERATING MANUAL.

AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE

RANGER 9 TO K867 ADAPTER CONNECTION DIAGRAM

WARNINGDo not operate with panels open.Disconnect NEGATIVE (-) BATTERY LEADbefore servicing.Do not touch electrically live parts.

Keep guards in place.Keep away from moving parts.Only qualified personnel should install,useor service this equipment.

Page 35: RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process

– 33 –

12 -16-93

M17094

N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION.

N.C. INSULATE EACH UNUSED LEAD INDIVIDUALLY.

SPARE

82

81

42

41

31

32

2

4

21

GND

75

76

77

31

32

2

4

21

GND

N.C.

K867 UNIVERSALADAPTER PLUG

N.D.

N.D. SPLICE LEADS AND INSULATE.

TO WORK ELECTRODE

TO WORK

CAUTION :

A

B

C

14 PIN

AMPHENOL

K196INPUT CABLE

LN-8WIREFEEDER

ELECTRODE CABLETO WIRE FEED UNIT

N.B. USE POLARITY SWITCH TO SET FOR DESIRED ELECTRODE POLARITY. POSITION THE OUTPUT SELECTOR SWITCH TO A CV POSITION.

ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE

DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED INTHE ENGINE WELDER OPERATING MANUAL.

AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE

RANGER 9 / K867 / LN-8 CONNECTION DIAGRAM

"REMOTELY CONTROLLED " POSITION.PLACE OUTPUT CONTROL SWITCH IN "OUTPUT CONTROL REMOTE" POSITION. PLACE WELDING TERMINALS SWITCH TO

N.E. PLACE IDLER SWITCH IN "HIGH" IDLE POSITION.

WARNINGDo not operate with panels open.Disconnect NEGATIVE (-) BATTERY LEADbefore servicing.Do not touch electrically live parts.

Keep guards in place.Keep away from moving parts.Only qualified personnel should install,useor service this equipment.

12 -16-93

M17100

ELECTRODE CABLE

TO WORK ELECTRODE

14 PINAMPHENOL

TO WORK

TO WIRE FEED UNIT

CAUTION :

ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE

DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED INTHE ENGINE WELDER OPERATING MANUAL.

N.B. WELDING CABLES MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTUREAPPLICATIONS. SEE OPERATING MANUAL.

K592 CONTROL CABLE

N.A. USE POLARITY SWITCH TO SET FOR DESIRED ELECTRODE POLARITY. POSITION THE OUTPUT SELECTOR SWITCH TO A CV POSITION.

N.C. IF OPTIONAL REMOTE OUTPUT CONTROL IS USED, PLACE OUTPUT CONTROL SWITCH IN "OUTPUT CONTROL REMOTE" POSITIION.

AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE

RANGER 9 / LN-742 CONNECTION DIAGRAM

TO LN-742 INPUTCABLE PLUG

PLACE WELDER TERMINALS SWITCH TO "REMOTELY CONTROLLED" POSITION.

N.D. PLACE IDLER SWITCH IN "AUTO" OR "HIGH" IDLE POSITION AS DESIRED.

WARNINGDo not operate with panels open.Disconnect NEGATIVE (-) BATTERY LEADbefore servicing.Do not touch electrically live parts.

Keep guards in place.Keep away from moving parts.Only qualified personnel should install,useor service this equipment.

Page 36: RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process

12 -16-93

M17214

ELECTRODE CABLE

TO WORK ELECTRODE

14 PINAMPHENOL

TO WORK

TO WIRE FEED UNIT

CAUTION :

ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE

DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED INTHE ENGINE WELDER OPERATING MANUAL.

N.B. WELDING CABLES MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTUREAPPLICATIONS. SEE OPERATING MANUAL.

N.A. USE POLARITY SWITCH TO SET FOR DESIRED ELECTRODE POLARITY. POSITION THE OUTPUT SELECTOR SWITCH TO A CV POSITION.

N.C. IF OPTIONAL REMOTE OUTPUT CONTROL IS USED, PLACE OUTPUT CONTROL SWITCH IN "OUTPUT CONTROL REMOTE" POSITIION.

AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE

PLACE WELDER TERMINALS SWITCH TO "REMOTELY CONTROLLED" POSITION.

N.D. PLACE IDLER SWITCH IN "AUTO" OR "HIGH" IDLE POSITION AS DESIRED.

RANGER 9 / LN-25 WITH 42 VOLT REMOTE OUTPUT CONTROL MODULE CONNECTION DIAGRAM

K626-XX INPUT CABLE ASSEMBLY

TO LN-25 INPUTCABLE PLUG

WARNINGDo not operate with panels open.Disconnect NEGATIVE (-) BATTERY LEADbefore servicing.Do not touch electrically live parts.

Keep guards in place.Keep away from moving parts.Only qualified personnel should install,useor service this equipment.

– 34 –

4-19-96D

S20909

WARNING

can killELECTRIC SHOCK

- +

POWER SOURCE

6-PINPLUG

ELECTRODE LEADWORK SENSE LEAD

**

BYPASSCAPACITOR

KIT

*

HI-FREQ KITINPUT POWER

*

5-PINPLUG

K915-1AMPTROLADAPTER

6-SOCKETRECEPTACLE

K963 HAND

AMPTROL

K870 FOOT

AMPTROL

OR

*KIT FOR CONNECTION INFORMATION.SEE INSTRUCTIONS INCLUDED WITH HI-FREQ

THIS ADAPTER ALLOWS AN AMPTROL TO OPERATE A

OUTPUT CURRENT OF A LINCOLN POWER SOURCE.(THE POWER SOURCE MUST BE EQUIPPED WITH A6-PIN REMOTE CONTROL AMPHENOL CONNECTOR.)SEE THE HI-FREQ KIT AND POWER SOURCE INSTRUC-

AND CONTROL SETTINGS.TION MANUAL FOR INFORMATION ON PROPER SWITCH

OF THE WELDING POWER SOURCE "OFF"

TURN THE ENGINE OR POWER SWITCH

BEFORE CONNECTING OR DISCONNECTING

PLUGS TO WELDING POWER SOURCE.

K915-1 AMPTROL ADAPTER FOR K799 HI-FREQ KITS

K799 HI-FREQ KIT WHILE REMOTELY CONTROLLING THE

K799 HI-FREQ KIT

Page 37: RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process

CRM23615

M17902

TO WORK ELECTRODE

TO WORK

CAUTION :

ELECTRODE CABLETO CONTROL MODULE

WARNINGDo not operate with panels open.

Disconnect NEGATIVE (-) BATTERY LEADbefore servicing.

Do not touch electrically live parts.

Keep guards in place.Keep away from moving parts.

Only qualified personnel should install,useor service this equipment.

N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION.N.B. USE POLARITY SWITCH TO SET FOR DESIRED ELECTRODE POLARITY. POSITION THE OUTPUT SELECTOR SWITCH TO A CV POSITION.

ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE

DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED INTHE ENGINE WELDER OPERATING MANUAL.

AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE

PLACE WELDING TERMINALS SWITCH TO "REMOTELY CONTROLLED" POSITION.

N.D. PLACE IDLER SWITCH IN "HIGH" IDLE POSITION.

RANGER

14 PIN WIRE FEEDERRECEPTACLE

K488 SGCONTROL MODULE

BE SURE THAT CONTROL MODULE MODE SLIDE SWITCH IS IN THE "LINCOLN" (CONTACT CLOSURE) POSITION BEFORE ATTEMPTING TO OPERATE

CONTROL MODULE. INCORRECT SWITCH POSITION COULD RESULT IN DAMAGE TO THE CONTROL MODULE AND/OR POWER SOURCE.

K487-25SPOOL GUN

K691-10INPUT CABLE

6 PIN REMOTERECEPTACLE

115V RECEPTACLE

RANGER 9 AND 10LX / K691-10 / K488 / K487 SPOOL GUN CONNECTION DIAGRAM

N.C. IF OPTIONAL K857 REMOTE OUTPUT CONTROL IS CONNECTED TO 6 PIN RECEPTACLE,PLACE OUTPUT CONTROL SWITCH IN "OUTPUT CONTROL REMOTE" POSITION.

– 35 –MAR 95

Page 38: RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process

– 36 –

DIM

EN

SIO

N P

RIN

T

- R

ang

er 9

CEN

TER

OF

GR

AVIT

Y W

ITH

OIL

INEN

GIN

E AN

D E

MPT

Y FU

EL T

ANK

.

30.0

08.

80

UN

DER

CAR

RIA

GE

MO

UN

TIN

G H

OLE

S

17.0

0

9.09

L

2.75

OF

SHAF

T

42.0

0

30.0

0

C

9.31

9.29

9.09

26.5

9

REQ

UIR

ED W

ITH

K

OH

LER

EN

GIN

E)

FOR

OIL

FIL

TER

R

EMO

VAL

(NO

T12

.75~

.25

20.5

1

20.6

3 ~.

25

CEN

TER

OF

GR

AVIT

Y W

ITH

OIL

INEN

GIN

E AN

D E

MPT

Y FU

EL T

ANK

.

30.2

8

Page 39: RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process

WARNING

AVISO DEPRECAUCION

ATTENTION

WARNUNG

ATENÇÃO

Spanish

French

German

Portuguese

Japanese

Chinese

Korean

Arabic

READ AND UNDERSTAND THE MANUFACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TOBE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.

SE RECOMIENDA LEER Y ENTENDER LAS INSTRUCCIONES DEL FABRICANTE PARA EL USO DE ESTE EQUIPO Y LOSCONSUMIBLES QUE VA A UTILIZAR, SIGA LAS MEDIDAS DE SEGURIDAD DE SU SUPERVISOR.

LISEZ ET COMPRENEZ LES INSTRUCTIONS DU FABRICANT EN CE QUI REGARDE CET EQUIPMENT ET LES PRODUITS AETRE EMPLOYES ET SUIVEZ LES PROCEDURES DE SECURITE DE VOTRE EMPLOYEUR.

LESEN SIE UND BEFOLGEN SIE DIE BETRIEBSANLEITUNG DER ANLAGE UND DEN ELEKTRODENEINSATZ DES HER-STELLERS. DIE UNFALLVERHÜTUNGSVORSCHRIFTEN DES ARBEITGEBERS SIND EBENFALLS ZU BEACHTEN.

● Do not touch electrically live parts orelectrode with skin or wet clothing.

● Insulate yourself from work andground.

● No toque las partes o los electrodosbajo carga con la piel o ropamojada.

● Aislese del trabajo y de la tierra.

● Ne laissez ni la peau ni desvêtements mouillés entrer en contactavec des pièces sous tension.

● Isolez-vous du travail et de la terre.

● Berühren Sie keine stromführendenTeile oder Elektroden mit IhremKörper oder feuchter Kleidung!

● Isolieren Sie sich von denElektroden und dem Erdboden!

● Não toque partes elétricas eelectrodos com a pele ou roupamolhada.

● Isole-se da peça e terra.

● Keep flammable materials away.

● Mantenga el material combustiblefuera del área de trabajo.

● Gardez à l’écart de tout matérielinflammable.

● Entfernen Sie brennbarres Material!

● Mantenha inflamáveis bemguardados.

● Wear eye, ear and body protection.

● Protéjase los ojos, los oídos y elcuerpo.

● Protégez vos yeux, vos oreilles etvotre corps.

● Tragen Sie Augen-, Ohren- und Kör-perschutz!

● Use proteção para a vista, ouvido ecorpo.

Page 40: RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process

– 39 –

WARNING

AVISO DEPRECAUCION

ATTENTION

WARNUNG

ATENÇÃO

Spanish

French

German

Portuguese

Japanese

Chinese

Korean

Arabic

LEIA E COMPREENDA AS INSTRUÇÕES DO FABRICANTE PARA ESTE EQUIPAMENTO E AS PARTES DE USO, E SIGA ASPRÁTICAS DE SEGURANÇA DO EMPREGADOR.

● Keep your head out of fumes.● Use ventilation or exhaust to

remove fumes from breathing zone.

● Los humos fuera de la zona derespiración.

● Mantenga la cabeza fuera de loshumos. Utilice ventilación oaspiración para gases.

● Gardez la tête à l’écart des fumées.● Utilisez un ventilateur ou un

aspirateur pour ôter les fumées deszones de travail.

● Vermeiden Sie das Einatmen vonSchweibrauch!

● Sorgen Sie für gute Be- undEntlüftung des Arbeitsplatzes!

● Mantenha seu rosto da fumaça.● Use ventilação e exhaustão para

remover fumo da zona respiratória.

● Turn power off before servicing.

● Desconectar el cable dealimentación de poder de lamáquina antes de iniciar cualquierservicio.

● Débranchez le courant avantl’entretien.

● Strom vor Wartungsarbeitenabschalten! (Netzstrom völligöffnen; Maschine anhalten!)

● Não opere com as tampas removidas.● Desligue a corrente antes de fazer

serviço.● Não toque as partes elétricas nuas.

● Do not operate with panel open orguards off.

● No operar con panel abierto oguardas quitadas.

● N’opérez pas avec les panneauxouverts ou avec les dispositifs deprotection enlevés.

● Anlage nie ohne Schutzgehäuseoder Innenschutzverkleidung inBetrieb setzen!

● Mantenha-se afastado das partesmoventes.

● Não opere com os paineis abertosou guardas removidas.

Page 41: RANGER TM 9 IM511-D - Lincoln Electric › assets › servicenavigator... · For use with machines having Code Number 10378, 10379, 10539, 10540 and 10550 RANGER TM 9 Multi-Process

• Sales and Service through Subsidiaries and Distributors Worldwide •

Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com

• World's Leader in Welding and Cutting Products •