CO2 MACHINE FILTER ELEC. PANELS C G E S I G N N G I N E E R I N G a n d I N C S T R U C T U R A L A N D C I V I L E N G I N E E R S w w w . d a n d e i n c . u s B r e n t w o o d , T e n n e s s e e 3 7 0 2 7 1 6 4 5 W e s t g a t e C i r c l e f a x : 3 7 0 - 9 1 0 8 6 1 5 - 3 7 0 - 1 7 7 9 A R C H I T E C T S E-1 LIGHTING FLOOR PLAN LIGHTING LIGHTING FIXTURE SCHEDULE TYPE MANUFACTURER CATALOG NUMBER VOLT TYPE LAMPS QTY MOUNTING REMARKS E COOPER LIGHTING HALO H7T-LED14DR5630K 120 1 14W-LED RECESSED INTERIOR DOWNLIGHT E1 COOPER LIGHTING METALUX RWW-1BX40-I-120V-EB51 120 1 40W BIAX RECESSED 2' MENU BOARD LIGHT H COOPER LIGHTING METALUX 2GR8-432A-UNV-AD=ICN4P32N-U 120 4 F32W-T8 RECESSED 2X4 LAY-IN X1 EXITRONIX VEX-U-BP-WB-WH-EL90R 120 -- INCLUDED SURFACE EXIT LIGHT WITH EMERGENCY BATTERY XR EXITRONIX 2Z1P-GRAY -- INCLUDED SURFACE REMOTE EMERGENCY LIGHTS C-22 C-20 7 L2 READER BOARD SITE SIGN SPARE SPARE SPARE SPARE SPARE SPARE C-7 C-7 4 L2 SPARE SPARE C-3 C-1 J L2 SPARE SPARE SPARE SPARE C-11 C-17 C-6 EXTERIOR DOWNLIGHTS SECURITY WALL PACK AWNING LIGHTS EXTERIOR TUBE LIGHTS ROOF TOWER LIGHTS LOT LTS LOT LTS SPARE SPARE SPARE SPARE C-2 C-4 LIGHTING CONTROL DIAGRAMS NO SCALE (MOUNTED IN ELEECTRICAL EQUIP. SEE SHEET E-3) A COOPER LIGHTING HALO H7T-LED14DR5630K 120 1 14W-LED RECESSED EXTERIOR DOWNLIGHT X2 EXITRONIX LL50H 120 -- INCLUDED SURFACE EMERGENCY LIGHT WITH EMERGENCY BATTERY FOR ANY QUESTIONS REGARDING THE FIXTURE PACKAGE. NOTES: LIGHTING FIXTURE PACKAGE TO BE PURCHASED THROUGH VILLA LIGHTING. CALL BRYAN BIRDWELL AT 1-800-325-0963 * COLOR AND LENGTH TO BE DETERMINED. PROVIDE ALL ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION. BUILDING SIGN C-8 11. CENTER LIGHTS OVER AWNINGS, TYPICAL. WITH HOOD SUPPLIER/INSTALLER. 10. J-BOX FOR HOOD CONTROLS. COORDINATE ALL REQUIREMENTS 9. SITE SIGN. SEE SITE PLAN FOR LOCATION. 8. READER BOARD. SEE SITE PLAN FOR LOCATION. 7. SITE LIGHTING. SEE SITE PLAN FOR QUANTITIES AND LOCATIONS. FOR LOCATION. 6. DRIVE-THRU MENU BOARD AND SPEAKER. SEE SITE PLAN 5. NIGHT LIGHT. OF CONNECTION POINTS. SEE SHEET E-2 FOR CIRCUITS. 4. COORDINATE LIGHTS WITH WALK-IN MANUFACTURER FOR LOCATION HEIGHTS AND LOCATIONS OF THE EXTERIOR LIGHTING FIXTURES. 3. SEE THE ARCHITECTURAL EXTERIOR ELEVATIONS FOR MOUNTING RESTROOM LIGHTING CIRCUIT. RESTROOM IS ENERGIZED. FAN TO BE CONTROLLED THROUGH 2. TO RESTROOM EXHAUST FAN EF-3. FAN SHALL RUN IF EITHER ON THE BREAKER. LIGHITNG AND EMERGENCY EQUIPMENT SHALL HAVE A LOCK "UNIT EQUIPMENT". THE CIRCUIT FEEDING THE NIGHT ENERGIZED 24 HOURS IN COMPLIANCE WITH NEC 700-12(E) TO THE NL (NIGHT LIGHTING) CIRCUIT A-6 AND REMAIN 1. EXIT AND EMERGENCY LIGHTING UNITS TO BE CONNECTED PLAN NOTES: UNWRAPPED SINGLE SERVICE AND SINGLE USE ARTICLES. LAMPS WHERE THERE IS EXPOSED FOOD, CLEAN EQUIPMENT, UTENSILS, LINENS, OR G. ALL LIGHT FIXTURE LAMPS SHALL BE SHEILDED, COATED, OR OTHERWISE SHATTER-RESISTANT LIGHTING IS TO BE PRE-WIRED TO A JUNCTION BOX. REQUIREMENTS FOR THE UNITS' LIGHTING. THE WALK-IN UNITS' OF THE WALK-IN COOLER/FREEZER FOR THE ROUGH-IN LOCATIONS AND F. CONTRACTOR SHALL COORDINATE WITH THE SUPPLIER AND INSTALLER HEIGHTS OF WALL MOUNTED LIGHTING FIXTURES. (INTERIOR AND EXTERIOR) FOR THE LOCATIONS AND MOUNTING E. CONTRACTOR SHALL REFER TO THE ARCHITECTURAL ELEVATIONS FOR COORDINATION WITH ROOF TRUSSES. AND OTHER CEILING MOUNTED ITEMS. GRID TO BE ADJUSTED LIGHTING FIXTURES IN RELATION TO THE CEILING GRID REFLECTED CEILING PLAN FOR THE LOCATIONS OF THE D. CONTRACTOR SHALL REFER TO THE ARCHITECTURAL C. SEE SHEET E-4 FOR GENERAL ELECTRIC NOTES. B. SEE SHEET E-7 FOR SPECIFICATIONS. A. SEE SHEET E-3 FOR ELECTRICAL PANEL SCHEDULES. GENERAL NOTES: 7 7 THRU C C-1/3 THRU C C-2/4 THRU C C-20 8 WP J 6 WP J A-11 9 WP J THRU C C-22 30/1F/WP C TEXAS FLUORESCENTS OSL-254-MV 120 2 54W-T5HO SURFACE OUTDOOR SIGN LIGHTER C1 TEXAS FLUORESCENTS OSL-2548-MV 120 4 54W-T5HO SURFACE OUTDOOR SIGN LIGHTER B COOPER LIGHTING LUMARK XTOR2A-N 120 1 LED WALL EXTERIOR WALL PACK F BARBICAN 16-0424-10H-ACW- OA-LF-736-NT-BA-INC 120 2 7W-LED PENDANT DRUM PENDANT G HI-LITE MFG H-15112-11-CORD-LED11A 120 1 11W-LED PENDANT WAREHOUSE SHADE PENDANT S CREE LIGHTING OSQ-A-DA-3ME-A-40K-208-BZ ON CL-SSP-4011-25-TT-BZ 208 1 112W LED 25' POLE ON 2' BASE PARKING LOT LIGHT C1 C C1 C1 X1 X1 X1 X1 X2 X2 E E E E E E E E E E E E E E E E E E E A A E E E E E E E E E E E E E E E E F E E E E G G G G H H H H H H H H H H H H E E E E E 5 5 5 5 XR 5 XR C1 E1 E1 E1 E1 E1 4 4 E E E J C X1 XR D D D J J J J 1 1 1 1 1 1 1 1 3 3 3 3 3 3 TYPICAL 10 10 2 A-3 A-1 A-6 A-4 A-7 A-2 A-5 A-9 C-11 C-17 3 A-13 A-15 X2 1 E1 11 11 11 11 11 11 ON C-7 A ON C-7 B B E C1 3 11 G G X1 E G C-7 CANOPY WITH INCLUDED CANOPY WITH INCLUDED C1 C1 C1 3 3 3 11 11 11 D LEDALUX LIGHTING LED-CFX-B-7.5 LED-FX-PS-120-4-WP 120 -- LED'S SURFACE EXTERIOR LED LIGHTING SCALE 1/4" = 1'-0" FLOOR PLAN T R A S H D1 E1 Revisions: Job Number: 68F0019 1: 27: 58 PM 1/ 11/ 2017 G:\ 16285\ E- 1. DGN r s ou t h a ll 4: 0 ' : " / i n . CD-82E-16-SD-30 P R O F E S S I O N A L E N G I N E E R S T A T E O F K E N T U C K Y R E G I S T E R E D P.B. BILLINGS 11,369 1/13/17 JANUARY 13, 2017 B A R D S TO W N , KY NO R TH 3 R D S TR EET A N EW L O C A TI ON FO R C A P TA I N D ' S TR I TON I NV ES TM EN TS B A R D S TO W N , KY 40004 1020 B L OO M FI EL D R D . Revised Bid Set
12
Embed
R: 000 274 C-SIZE (1) - BCD Inc. · PDF file14w-led recessed ... f32w-t8 recessed 2x4 lay-in x1 exitronix vex-u-bp-wb ... exterior tube lights roof tower lights lot lts
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
CO2
MACHINE
FILTER
ELEC. PANELS
C
G
E S I G N
N G I N E E R I N G
a n d
I N C
S T R U C T U R A L A N D C I V I L E N G I N E E R S
w w w . d a n d e i n c . u s
B r e n t w o o d , T e n n e s s e e 3 7 0 2 7
1 6 4 5 W e s t g a t e C i r c l e
f a x : 3 7 0 - 9 1 0 8 6 1 5 - 3 7 0 - 1 7 7 9
A R C H I T E C T S
E-1LIGHTING
FLOOR PLAN
LIGHTING
LIGHTING FIXTURE SCHEDULE
TYPE MANUFACTURER CATALOG NUMBERVOLT TYPE
LAMPS
QTYMOUNTING REMARKS
E COOPER LIGHTING
HALO
H7T-LED14DR5630K
120
1
14W-LED
RECESSED
INTERIOR DOWNLIGHT
E1 COOPER LIGHTING
METALUX
RWW-1BX40-I-120V-EB51
120
1
40W BIAX
RECESSED
2' MENU BOARD
LIGHT
H COOPER LIGHTING
METALUX
2GR8-432A-UNV-AD=ICN4P32N-U
120
4
F32W-T8
RECESSED
2X4 LAY-IN
X1 EXITRONIX
VEX-U-BP-WB-WH-EL90R
120
--
INCLUDED
SURFACE
EXIT LIGHT WITH
EMERGENCY BATTERY
XR EXITRONIX
2Z1P-GRAY
--
INCLUDED
SURFACE
REMOTE EMERGENCY
LIGHTS
C-22
C-20
7L2
READER BOARD
SITE SIGN
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
C-7
C-7
4L2
SPARE SPARE
C-3
C-1
JL2
SPARE
SPARE
SPARE
SPARE
C-11
C-17
C-6
EXTERIOR DOWNLIGHTS
SECURITY WALL PACK
AWNING LIGHTS
EXTERIOR TUBE LIGHTS
ROOF TOWER LIGHTS
LOT LTS
LOT LTS
SPARE
SPARE
SPARE
SPARE
C-2
C-4
LIGHTING CONTROL DIAGRAMSNO SCALE (MOUNTED IN ELEECTRICAL EQUIP. SEE SHEET E-3)
A COOPER LIGHTING
HALO
H7T-LED14DR5630K
120
1
14W-LED
RECESSED
EXTERIOR DOWNLIGHT
X2 EXITRONIX
LL50H
120
--
INCLUDED
SURFACE
EMERGENCY LIGHT WITH
EMERGENCY BATTERY
FOR ANY QUESTIONS REGARDING THE FIXTURE PACKAGE.
NOTES: LIGHTING FIXTURE PACKAGE TO BE PURCHASED THROUGH VILLA LIGHTING. CALL BRYAN BIRDWELL AT 1-800-325-0963
* COLOR AND LENGTH TO BE DETERMINED. PROVIDE ALL ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION.
BUILDING SIGN C-8
11. CENTER LIGHTS OVER AWNINGS, TYPICAL.
WITH HOOD SUPPLIER/INSTALLER.
10. J-BOX FOR HOOD CONTROLS. COORDINATE ALL REQUIREMENTS
9. SITE SIGN. SEE SITE PLAN FOR LOCATION.
8. READER BOARD. SEE SITE PLAN FOR LOCATION.
7. SITE LIGHTING. SEE SITE PLAN FOR QUANTITIES AND LOCATIONS.
FOR LOCATION.
6. DRIVE-THRU MENU BOARD AND SPEAKER. SEE SITE PLAN
5. NIGHT LIGHT.
OF CONNECTION POINTS. SEE SHEET E-2 FOR CIRCUITS.
4. COORDINATE LIGHTS WITH WALK-IN MANUFACTURER FOR LOCATION
HEIGHTS AND LOCATIONS OF THE EXTERIOR LIGHTING FIXTURES.
3. SEE THE ARCHITECTURAL EXTERIOR ELEVATIONS FOR MOUNTING
RESTROOM LIGHTING CIRCUIT.
RESTROOM IS ENERGIZED. FAN TO BE CONTROLLED THROUGH
2. TO RESTROOM EXHAUST FAN EF-3. FAN SHALL RUN IF EITHER
ON THE BREAKER.
LIGHITNG AND EMERGENCY EQUIPMENT SHALL HAVE A LOCK
"UNIT EQUIPMENT". THE CIRCUIT FEEDING THE NIGHT
ENERGIZED 24 HOURS IN COMPLIANCE WITH NEC 700-12(E)
TO THE NL (NIGHT LIGHTING) CIRCUIT A-6 AND REMAIN
1. EXIT AND EMERGENCY LIGHTING UNITS TO BE CONNECTED
PLAN NOTES:
UNWRAPPED SINGLE SERVICE AND SINGLE USE ARTICLES.
LAMPS WHERE THERE IS EXPOSED FOOD, CLEAN EQUIPMENT, UTENSILS, LINENS, OR
G. ALL LIGHT FIXTURE LAMPS SHALL BE SHEILDED, COATED, OR OTHERWISE SHATTER-RESISTANT
LIGHTING IS TO BE PRE-WIRED TO A JUNCTION BOX.
REQUIREMENTS FOR THE UNITS' LIGHTING. THE WALK-IN UNITS'
OF THE WALK-IN COOLER/FREEZER FOR THE ROUGH-IN LOCATIONS AND
F. CONTRACTOR SHALL COORDINATE WITH THE SUPPLIER AND INSTALLER
HEIGHTS OF WALL MOUNTED LIGHTING FIXTURES.
(INTERIOR AND EXTERIOR) FOR THE LOCATIONS AND MOUNTING
E. CONTRACTOR SHALL REFER TO THE ARCHITECTURAL ELEVATIONS
FOR COORDINATION WITH ROOF TRUSSES.
AND OTHER CEILING MOUNTED ITEMS. GRID TO BE ADJUSTED
LIGHTING FIXTURES IN RELATION TO THE CEILING GRID
REFLECTED CEILING PLAN FOR THE LOCATIONS OF THE
D. CONTRACTOR SHALL REFER TO THE ARCHITECTURAL
C. SEE SHEET E-4 FOR GENERAL ELECTRIC NOTES.
B. SEE SHEET E-7 FOR SPECIFICATIONS.
A. SEE SHEET E-3 FOR ELECTRICAL PANEL SCHEDULES.
GENERAL NOTES:
7 7
THRU C
C-1/3
THRU C
C-2/4
THRU C
C-20
8
WPJ6
WPJ
A-11
9
WPJ
THRU C
C-22
30/1F/WP
C TEXAS FLUORESCENTS
OSL-254-MV
120
2
54W-T5HO
SURFACE
OUTDOOR SIGN
LIGHTER
C1 TEXAS FLUORESCENTS
OSL-2548-MV
120
4
54W-T5HO
SURFACE
OUTDOOR SIGN
LIGHTER
B COOPER LIGHTING
LUMARK
XTOR2A-N
120
1
LED
WALL
EXTERIOR WALL PACK
F BARBICAN
16-0424-10H-ACW-
OA-LF-736-NT-BA-INC
120
2
7W-LED
PENDANT
DRUM PENDANT
G HI-LITE MFG
H-15112-11-CORD-LED11A
120
1
11W-LED
PENDANT
WAREHOUSE SHADE
PENDANT
S CREE LIGHTING
OSQ-A-DA-3ME-A-40K-208-BZ ON
CL-SSP-4011-25-TT-BZ
208
1
112W LED
25' POLE ON
2' BASE
PARKING LOT LIGHT
C1
C
C1
C1
X1
X1
X1
X1
X2 X2
E E E E E E
EEE
EEEE
E
E E E E
E
A
A
E
E
E
E
E
E E
E E
E
E
E
E E
EE
F
E
E
E
E
G
G
G
G
H
H
H H
H
H H
H
H
H H
H
E
E E
E E
5
5
5
5
XR
5
XR
C1
E1 E1 E1 E1 E1
4
4
E E E
J
C
X1
XR
D
D
DJ J
J
J
1
1 1
1
1
1
1
1
3
3
3
3
3
3 TYPICAL
10
10
2
A-3
A-1
A-6
A-4
A-7
A-2
A-5
A-9
C-11
C-17
3
A-13
A-15
X2
1
E1
11
11
11
11
11
11
ON C-7
A
ON C-7
B B
E
C1311
G
G
X1
E
G
C-7
CANOPY
WITH
INCLUDED
CANOPY
WITH
INCLUDED
C1
C1
C1
3
3
3
11
11
11
D LEDALUX LIGHTING
LED-CFX-B-7.5
LED-FX-PS-120-4-WP
120
--
LED'S
SURFACE
EXTERIOR LED
LIGHTING
SCALE 1/4" = 1'-0"
FLOOR PLAN
TR
AS
H
D1 E1
Revisions:
Job Number:68F0019
1:2
7:5
8 P
M
1/
11/
2017
G:\
16285\
E-
1.D
GN
rsouthall
4:0 ':" / in.
CD-82E-16-SD-30
PR
OF
E
SSIONAL E
NG
INE
ER
ST
A
TE O
F KENTU
CK
Y
RE
GISTERED
P.B.
BILLINGS
11,369
1/13/17
JANUARY 13, 2017
BA
RD
ST
OW
N,
KY
NO
RT
H 3
RD S
TR
EE
T
A
NE
W L
OC
ATIO
N F
OR
CA
PT
AIN
D'S
TRIT
ON IN
VE
ST
ME
NT
S
BA
RD
ST
OW
N,
KY 4
00
04
10
20 B
LO
OM
FIE
LD R
D.
Rev
ised
Bid
Set
CO2
MACHINE
FILTER
ELEC. PANELS
C
G
E S I G N
N G I N E E R I N G
a n d
I N C
S T R U C T U R A L A N D C I V I L E N G I N E E R S
w w w . d a n d e i n c . u s
B r e n t w o o d , T e n n e s s e e 3 7 0 2 7
1 6 4 5 W e s t g a t e C i r c l e
f a x : 3 7 0 - 9 1 0 8 6 1 5 - 3 7 0 - 1 7 7 9
A R C H I T E C T S
POWERE-2
POWER
FLOOR PLAN
PB
J
B
J
J
J
GENERAL ELECTRICAL LEGEND
SYMBOL MTG. HGT.DESCRIPTION
CEILING OUTLET, SURFACE FIXTURE
CEILING OUTLET, SURFACE FIXTURE w/BATTERY BACK UP
CEILING OUTLET, RECESSED FIXTURE
CEILING OUTLET, RECESSED FIXTURE w/BATTERY BACK UP
BRACKET OUTLET
SURFACE FLUORESCENT LIGHTING FIXTURE
RECESSED FLUORESCENT LIGHTING FIXTURE
FLUORESCENT STRIP LIGHT FIXTURE
SINGLE POLE SWITCHS 48" AFF
THREE-WAY SWITCHS3 48" AFF
FOUR-WAY SWITCH S4 48" AFF
DUPLEX GROUNDING RECEPTACLE 18" AFF
DUPLEX GROUNDING RECEPTACLE ABC
DOUBLE DUPLEX GROUNDING RECEPTACLE 18" AFF
JUNCTION OR PULL BOXJ
MOTOR, E.F. DENOTES EXHAUST FAN
MANUAL MOTOR STARTER OR RELAY CONTROLSM
MAGNETIC MOTOR STARTER OR TERMINAL CONNECTION
SAFETY SWITCH, WP INDICATES NEMA 3R, FUSED, U.O.N.
LIGHTING OR POWER PANEL
MAIN OR SUB-DISTRIBUTION PANEL
TRANSFORMERT
TIME CLOCK - SEE SPECSTC
CONTACTOR - SEE SPECSC
PHOTO-ELECTRIC SWITCH - AIM NORTHEAST, SEE SPECSPE
CONDUIT, CONCEALED IN CEILING OR WALL
CONDUIT, CONCEALED IN SLAB OR BELOW FLOOR/GRADE
CONDUIT, EXPOSED
CONDUIT, TURNING UP
CONDUIT, TURNING DOWN
T CONDUIT, TELEPHONE SYSTEM
EP CONDUIT, ELECTRICAL PRIMARY
ES CONDUIT, ELECTRICAL SECONDARY
WP WEATHERPROOF
GROUND FAULT CURRENT INTERRUPTINGG
AFF ABOVE FINISHED FLOOR
ABC ABOVE COUNTER
UON UNLESS OTHERWISE NOTED
TTB TELEPHONE TERMINAL BOARD
TVSS TRANSIENT VOLTAGE SURGE PROTECTOR
18" AFFMULTI USE OUTLET FOR VOICE, DATA, VIDEO (1"C. TO ABOVE CEILING)
ABCMULTI USE OUTLET FOR VOICE, DATA, VIDEO ABOVE COUNTER (1"C. TO ABOVE CEILING)
TELEPHONE FLOOR OUTLET, SEE SPECS
TELEPHONE OUTLET, WALL MOUNTED 48" AFFW
208 VOLT RECEPACLE,COORDINATE NEMA TYPE AND ALL REQUIREMENTS WITH EQUIPMENT 18" AFF
DIMMER SWITCH - SLIDE TYPE, WATTAGE AS REQUIREDSD 48" AFF