G-Code/E2 Series 1 Quick Start Guide G-Code/EEC-2120 This manual provides instructions for quick installation and basic configuration of your IP device. 1. Part names and positions Please check names and positions of each part with the following image. * The video input configuration must be set before you turn on the device. Changing the setting after the device is turned on will not affect the configuration unless you reboot the device. Input Configuration Switch (PAL/NTSC) OFF PAL NTSC Reset Switch * Models herein and their appearance are subject to change without any prior notice.
8
Embed
Quick Start Guide G-Code/EEC-2120 - Geutebrück...G-Code/E2 Series 1 Quick Start Guide G-Code/EEC-2120 This manual provides instructions for quick installation and basic configuration
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
G-Code/E2 Series
1
Quick Start Guide G-Code/EEC-2120
This manual provides instructions for quick installation and basic configuration of your IP device.
1. Part names and positions
Please check names and positions of each part with the following image. *
The video input configuration must be set before you turn on the device. Changing the setting after the device is turned on will not affect the configuration unless you reboot the device.
Input Configuration Switch (PAL/NTSC) OFF
PAL NTSC
Reset Switch
* Models herein and their appearance are subject to change without any prior notice.
G-Code/E2 Series
2
2. Install the IP device Install the blade to the rack chassis. To see the correct installation of a blade, refer to the following image below.
Inserting a blade *Remove a cover plate from the slot in which a blade will be mounted. This is done by unfastening the screws with a screw driver on each side of the cover.
1. Insert the blade into the rack chassis. Make sure the blade is properly aligned with the rail.
2. Push back the blade completely.
3. Tighten the screws by turning them clockwise. Ejecting a blade
1. Unlock the two screws on both sides of the blade.
2. Grasp the blade and pull it out as shown in the above image
3. Remove the blade from the rack chassis.
Inserting a blade Ejecting a blade
UnlockLock
Unlock Lock
G-Code/E2 Series
3
3. Set up network environment Set up network environment The default IP address of the device is 192.168.XXX.XXX. Users can identify the IP address of the device from converting the MAC address’s hexadecimal numbers, which is attached to the device. Be sure that the device and PC are on a same area network before running the installation. If the network segment was different between your PC and the device, change your PC’s settings as below.
IP address : 192.168.xxx.xxx Subnet mask : 255.255.0.0
Generic IP Environment
In case of generic private network environment where IP address 192.168.XXX.XXX are used, users may view the live streaming images on a web page using the device’s default IP address:
1. Convert the device’s MAC address to the IP address. Refer to the Hexadecimal-Decimal Conversion Chart at the end of the manual.
(The MAC address of the device is attached on the side or bottom of the device.)
2. Start the Microsoft® Internet Explorer web browser and enter the IP address of the device.
Web streaming and device configurations are supported through ActiveX program. When the ActiveX installation pop-up window appears, authorize and install the ActiveX setup.exe.
MAC address = 00-13-23-01-14-B1 → IP address = 192.168.20.177
Convert the last two sets of hexadecimal numbers to decimal numbers.
G-Code/E2 Series
4
IPAdminTool IPAdminTool is a management tool, which automatically scans all of the network products for users to perform administrative tasks, which includes network configurations, firmware update, device reboot, and device organizations.
To modify the device’s default IP address for customized network area; 1. Find the device from the IPAdminTool’s list and highlight the device’s name. 2. Right-click the mouse and select IP Address; IP Setup window appears.
3. In the IP Setup’s window, information under Local Network information displays the
user/PC’s network area information. Those information need to be incorporated to the IP Address, Subnet Mask, Gateway, and DNS boxes, except the last 2 sets of IP Address, which are to be the unique numbers for the device. Refer to the image above for the setting
4. Click Setup to complete the modification.
5. Enter the user name and the password, and then select Login.
(The default username and password are: root and admin.)
G-Code/E2 Series
5
4. View video on web page Once the device’s proper IP address has been identified, type the URL in a web browser to access the camera. At first time access, installation window may pop up.
1. When the browser asks to install the AxUMF software, click Install to proceed.
2. When Setup installation pop-up window appears, click Install to proceed with the rest
of the installation.
Depending on system OS and Internet Explorer version, installation experience may differ from one another. Figures described above are from Windows 7, Internet Explorer 9 environment.
5. SETUP page
To set up the device configuration:
1. Click Setup on the upper left of the web page. The login page is displayed as below. 2. Enter the user name and the password, and then select OK.
(The default username and password are: root and admin.)
G-Code/E2 Series
6
6. Reboot
Perform the following procedures to reboot your device:
1. While the device is in use, press and hold the reset button.
2. Release the Reset button after 2 seconds.
3. Wait for the system to reboot.
Please do not hold for more than 2 seconds. Otherwise, the device may be switched to its Factory Default settings.
7. Factory Default
Resetting the device back to the factory default will initialize all parameters including the IP address back to the factory defaults. To reset to the factory default:
1. While the device is in use, press and hold the reset button for about 10 seconds. (LED blinks when the device is restored to factory default status.)
2. Wait for the system to reboot.
The factory default settings can be inferred as follows: IP address: 192.168.xx.yy Network mask: 255.255.0.0 Gateway: 192.168.0.1 User ID: root Password: admin
G-Code/E2 Series
7
8. Safe Mode Your device will get restarted in safe mode if the device does not completely boot certain times. The errors are mainly caused by these factors below:
* The power supply is continually unplugged certain times in the middle of system booting. * The firmware files required for system booting are damaged. * There are conflicts in the system settings.
You will see the page to indicate that your device is in safe mode and to guide you what to do in steps. Follow the instructions on the webpage according to each step.
There is another method to update firmware, which is using IPAdminTool. Please refer to ‘IPAdminTool User’s Manual.pdf’ for the detailed procedure.
If your device is still in safe mode after trying to update firmware, please contact your local agency to get further assistance.
The format of firmware file for safe mode itself is ‘ipn-SAFEMODE.~~~.enc’.
Browse
G-Code/E2 Series
8
Hexadecimal-Decimal Conversion Table Refer to the following table when converting the MAC address of your device to IP address.