Guidewire retriever Quick-Cross Capture Easy, reliable, safe guidewire retrieval and exchange during complex retrograde procedures
4

Quick-Cross Capture€¦ · 6.4 6.6 6.8 7.3 7.5 7.8 7.9 8.2 8.5 9.0 Note: Both models use the same balloon. *Rated burst pressure: 5ATM Quick-Cross Capture guidewire retriever –

Jul 29, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Quick-Cross Capture€¦ · 6.4 6.6 6.8 7.3 7.5 7.8 7.9 8.2 8.5 9.0 Note: Both models use the same balloon. *Rated burst pressure: 5ATM Quick-Cross Capture guidewire retriever –

Guidewire retriever

Quick-Cross Capture

Easy, reliable, safe

guidewire retrieval and exchange

during complex retrograde procedures

Page 2: Quick-Cross Capture€¦ · 6.4 6.6 6.8 7.3 7.5 7.8 7.9 8.2 8.5 9.0 Note: Both models use the same balloon. *Rated burst pressure: 5ATM Quick-Cross Capture guidewire retriever –

Easy, reliable, safe guidewire retrieval and exchange during complex retrograde proceduresDuring complex retrograde procedures, retrieving and exchanging guidewires can be difficult,

time-consuming and frustrating. The Philips Quick-Cross Capture guidewire retriever easily,

reliably and safely helps you retrieve and exchange guidewires with no damage either to the

wire or to the vessel. It can even retrieve prolapsed or damaged guidewires.

Easy to use

This novel retrieval catheter is inserted from above (antegrade or cross-over). Then, the

low-pressure balloon automatically centers the device within the vessel. The funnel

shape directs the guidewire into the lumen for quick exchange.

Inflate the low-pressure balloon to center the device

Inject contrast to confirm funnel is in proper position

Advance the retrograde guidewire towards the device…

…into the funnel...

…and up through the catheter to facilitate exchange.

1 2 3 4 5

1

2

3

4

5

Page 3: Quick-Cross Capture€¦ · 6.4 6.6 6.8 7.3 7.5 7.8 7.9 8.2 8.5 9.0 Note: Both models use the same balloon. *Rated burst pressure: 5ATM Quick-Cross Capture guidewire retriever –

The Quick-Cross Capture guidewire retriever easily, reliably and safely helps you retrieve and exchange guidewires during complex retrograde procedures.

Guidewire entering funnel

Guidewire approaching funnel

Guidewire retreived

Reliable

The Quick-Cross Capture guidewire

retriever brings reliability and predictability

to retrograde guidewire retrieval.

• Retrieves even prolapsed or damaged wires

• Effective in multiple vessels, including

femoral, popliteal and tibial

• Increases the predictably of

successful guidewire retrieval

Safe

The Quick-Cross Capture guidewire retriever

increases the ease and speed with which

guidewires can be retrieved and exchanged,

enhancing safety.

• Can be used in diseased vessels without the

dangers of manipulating a snare

• Retrograde wire access and retrieval with

Quick-Cross Capture is safe and less costly

than using a re-entry device when crossing

total occlusions

• Delivers predictably shorter procedure times1,

reducing radiation exposure

Page 4: Quick-Cross Capture€¦ · 6.4 6.6 6.8 7.3 7.5 7.8 7.9 8.2 8.5 9.0 Note: Both models use the same balloon. *Rated burst pressure: 5ATM Quick-Cross Capture guidewire retriever –

Philips 3721 Valley Centre Drive, Suite 500 San Diego, CA 92130 USA www.philips.com/IGTdevices

©2018 Koninklijke Philips N.V. All rights reserved. Some or all products manufactured by Spectranetics, a Philips company. Approved for external distribution. D019437-03 032018

Quick-Cross Capture guidewire retriever

Model number

Product description

Funnel size (mm)

Catheter length (cm)

Guidwire compatibility (in)

Catheter size (F)

Sheath compatibility (F)

519-106

(formerly U106)

6mm guidewire

retriever catheter

6 110 up to 0.035 5.5 6

Pressure (ATM) 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0*

Balloon diameter (mm)

6.4 6.6 6.8 7.3 7.5 7.8 7.9 8.2 8.5 9.0

Note: Both models use the same balloon.

*Rated burst pressure: 5ATM

Quick-Cross Capture guidewire retriever – Important safety information

Indications

The Quick-Cross Capture guidewire retriever is intended to be used in conjunction with a steerable guidewire to access discrete regions of the vasculature and for guidewire exchange. The Quick-Cross Capture guidewire retriever is not intended for use in the coronary, cerebral or carotid vasculature.

Contraindications

None known.

For additional information, please see the IFU.

1 Data on file