Top Banner
Quality Petroleum Equipment Solutions for Over 20 Years Reducing/Eliminating MLLD False Reducing/Eliminating MLLD False Alarms Alarms The ARM-4073 The ARM-4073
13

Quality Petroleum Equipment Solutions for Over 20 Years Reducing/Eliminating MLLD False Alarms The ARM-4073.

Dec 28, 2015

Download

Documents

Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Quality Petroleum Equipment Solutions for Over 20 Years Reducing/Eliminating MLLD False Alarms The ARM-4073.

Quality Petroleum EquipmentSolutions for Over 20 Years

Reducing/Eliminating MLLD False AlarmsReducing/Eliminating MLLD False Alarms

The ARM-4073The ARM-4073

Page 2: Quality Petroleum Equipment Solutions for Over 20 Years Reducing/Eliminating MLLD False Alarms The ARM-4073.

What is an ARM?

Auto Repressurization Module

ARM-4073

Page 3: Quality Petroleum Equipment Solutions for Over 20 Years Reducing/Eliminating MLLD False Alarms The ARM-4073.
Page 4: Quality Petroleum Equipment Solutions for Over 20 Years Reducing/Eliminating MLLD False Alarms The ARM-4073.

Why Do We Build the ARM-4073?

To increase confidence in the leak detection system, by eliminating thermal induced false alarms.

Page 5: Quality Petroleum Equipment Solutions for Over 20 Years Reducing/Eliminating MLLD False Alarms The ARM-4073.

How Does Thermal Contraction Cause Slow Flow?

Thermal contraction reduces volume/pressure in the line when the submersible pump is off.

Vapor pockets form in the line to replace the (contracted) liquid.

Page 6: Quality Petroleum Equipment Solutions for Over 20 Years Reducing/Eliminating MLLD False Alarms The ARM-4073.

Thermal Contraction Continued

The leak detector cannot refill the line and compress the vapor pocket in the 4-5 seconds available.

Therefore: leak detector is still in slow-flow at opening of nozzle = false alarm.

Page 7: Quality Petroleum Equipment Solutions for Over 20 Years Reducing/Eliminating MLLD False Alarms The ARM-4073.

How Does the ARM Combat Thermal Contraction?

By cycling the submersible to repressurize the line.

Page 8: Quality Petroleum Equipment Solutions for Over 20 Years Reducing/Eliminating MLLD False Alarms The ARM-4073.

Doesn’t That Defeat the Purpose of the Leak Detector, Preventing It From Working?

Not in the manner the ARM is designed to work.

This is the difference between

an ARM and a cycle timer.

Page 9: Quality Petroleum Equipment Solutions for Over 20 Years Reducing/Eliminating MLLD False Alarms The ARM-4073.

How Does the ARM Function?

Allow the submersible to stay off long enough for the leak detector

to reset if there is a 2 GPH leak (or less).

Cycle the submersible on and check for a leak.

Page 10: Quality Petroleum Equipment Solutions for Over 20 Years Reducing/Eliminating MLLD False Alarms The ARM-4073.

How Do We Know the Leak Detector Is Reset?

Each line is unique.

To ensure the leak detector is reset, we have the installer measure the bleed-back (line resiliency).

Page 11: Quality Petroleum Equipment Solutions for Over 20 Years Reducing/Eliminating MLLD False Alarms The ARM-4073.

Reset Continued

Bleed-back gives us the unique volume each line has before a leak detector is reset.

Cycle times are based upon this volume (set at install).

Page 12: Quality Petroleum Equipment Solutions for Over 20 Years Reducing/Eliminating MLLD False Alarms The ARM-4073.

The ARM-4073 Works to Eliminate Leak Detector False Alarms

Owners benefit through reduced service calls.

Greater Volume (Less down time).

Less customer frustration.

Page 13: Quality Petroleum Equipment Solutions for Over 20 Years Reducing/Eliminating MLLD False Alarms The ARM-4073.

Contact

Vaporless Manufacturing, Inc.8700 East Long Mesa Drive

Prescott Valley, Arizona 86314

Phone: 800-367-0185 or 928-775-5191Fax: 928-775-5309

Email: [email protected] Web Site: www.vaporless.com