29/12/2008 M.Pharm I Sem,2008-09,GCP Aurangabad 1 Quality Control & Evaluation Of Pharmaceutical Aerosols Prepared By: Mahesh W. Thube, M.Pharm I st Sem,
20
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Quality control & evaluation of aerosol

M.Pharm I Sem,2008-09,GCP Aurangabad

129/12/2008

Quality Control & Evaluation Of Pharmaceutical Aerosols

Prepared By: Mahesh W. Thube, M.Pharm Ist Sem,

GCP Aurangabad,

Page 2: Quality control & evaluation of aerosol

M.Pharm I Sem,2008-09,GCP Aurangabad

229/12/2008

•QUALITY CONTROL TESTS

It Includes the testing of :

» 1. Propellents

» 2. Valves, Actuator, Dip Tubes

» 3. Containers

» 4. Weight Checking

» 5. Leak Testing

» 6. Spray Testing

Page 3: Quality control & evaluation of aerosol

M.Pharm I Sem,2008-09,GCP Aurangabad

329/12/2008

1.Propellents:

All Propellents are accompanied by Specification sheet.

Parameter Tested By

Identification

Purity

Gas Chromatography

Moisture, Halogen, Non-Volatile Residue Determination

Page 4: Quality control & evaluation of aerosol

M.Pharm I Sem,2008-09,GCP Aurangabad

429/12/2008

2.Valves, Actuator, Dip-tubesSampling is done according to standard procedure as found in Military Standards “MIL-STD-105D”.

For metered dose aerosols test methods was developed by ‘Aerosol Specification Committee’

‘Industrial Pharmaceutical Technical Section

‘Academy Of Pharmaceutical Sciences.

The object of this test is to determine magnitude of valve delivery & degree of uniformity between individual valves.

Standard test solutions were proposed to rule out variation in valve delivery.

Page 5: Quality control & evaluation of aerosol

M.Pharm I Sem,2008-09,GCP Aurangabad

529/12/2008

Test SolutionsIngredients% w/w

Test Solutions ‘A’

Test Solutions ‘B’

Test Solutions ‘C’

Iso Propyl Myristate 0.10% 0.10% 0.10%

Dichloro Difluoro methane

49.95% 25.0% 50.25%

Dichloro tetrafluoro ethane

49.95% 25.0% 24.75%

Trichloro monofluoro methane

- - 24.9%

Alcohol USP - 49.9% -

Specific Gravity @ 25°c

1.384 1.092 1.388

Page 6: Quality control & evaluation of aerosol

M.Pharm I Sem,2008-09,GCP Aurangabad

629/12/2008

Testing Procedure:Take 25 valves & placed on containers,

Filled with specific test solution

Actuator with 0.020 inch orifice is attached.

Valve is actuated to fullest extent for 2 sec.

Repeat this for total 2 individual delivery from each 25 test units.

Individual delivery wt in mg.Valve delivery per actuation in µL = Specific gravity of test soln

Valve Acceptance: Deliveries Limit’s54µL or less ± 15%55 to 200 µL ± 10%

Page 7: Quality control & evaluation of aerosol

M.Pharm I Sem,2008-09,GCP Aurangabad

729/12/2008

Contd..

Of 50 deliveryIf 4 or more are outside limits : valves are rejected

If 3 delivery are outside limits : another 25 valves are tested : lot is rejected if more than 1 delivery outside

specification

If 2 delivery from 1 valve are beyond limits : another 25 valves are tested : lot is rejected if more than

1 delivery outside specification

Page 8: Quality control & evaluation of aerosol

M.Pharm I Sem,2008-09,GCP Aurangabad

829/12/2008

3.ContainersContainers are examined for defects in lining.

Q.C aspects includes degree of conductivity of electric current as measure of exposed metals.

Glass containers examined for Flaws.

4.Weight CheckingIs done by periodically adding tared empty aerosol container to filling lines which after filling with concentrate are removed & weighed.

Same procedure is used for checking weight of Propellents.

Page 9: Quality control & evaluation of aerosol

M.Pharm I Sem,2008-09,GCP Aurangabad

929/12/2008

5.Leak TestIs done by measuring the Crimp’s dimension & comparing.

Final testing of valve closure is done by passing filled containers through water bath.

6.Spray TestingIt is done for

»To clear dip tube of pure propellant & concentrate,

»To check for defects in valves & spray pattern.

Page 10: Quality control & evaluation of aerosol

M.Pharm I Sem,2008-09,GCP Aurangabad

1029/12/2008

Evaluation Tests:A. Flammability & combustibility:

1.Flash point

2.Flash Projection

B. Physicochemical characteristics:

1.Vapour pressure

2.Density

3.Moisture content

4.Identification of Propellents

Page 11: Quality control & evaluation of aerosol

M.Pharm I Sem,2008-09,GCP Aurangabad

1129/12/2008

Contnd…

C. Performance: 1. Aerosol valve discharge rate

2. Spray pattern

3. Dosage with metered valves

4. Net contents

5. Foam stability

6. Particle size determination

D. Biological testing: 1.Therapeutic activity

2.Toxicity studies

Page 12: Quality control & evaluation of aerosol

M.Pharm I Sem,2008-09,GCP Aurangabad

1229/12/2008

A. Flammability & combustibility:

» 1.Flash point: Apparatus : Open Cup Tag Apparatus

Test liquids temp. is allowed to increase

slowly & temp. at which vapors Ignite is

called as Flash Point .

» 2.Flame Projection:

Product is sprayed for 4 sec

onto flame & exact length is

measured with ruler.

Page 13: Quality control & evaluation of aerosol

M.Pharm I Sem,2008-09,GCP Aurangabad

1329/12/2008

B. Physicochemical characteristics:

Property Method

1. Vapor Pressure » Can Puncturing Device.

2. Density » Hydrometer,

» Pycnometer.

3. Moisture » Karl Fisher Method,

» Gas Chromatography.

4. Identification » Gas Chromatography,

» IR Spectroscopy.

Page 14: Quality control & evaluation of aerosol

M.Pharm I Sem,2008-09,GCP Aurangabad

1429/12/2008

C. Performance:

1.Aerosol valve discharge rate :Aerosol product of known weight is discharged for specific time.

By reweighing the container, the change in the wt. per time dispensed is the Discharge rate in gm/sec.

2. Spray pattern :The method is based on the

impingement of spray on

piece of paper that has

treated with Dye-Talc

mixture.

Page 15: Quality control & evaluation of aerosol

M.Pharm I Sem,2008-09,GCP Aurangabad

1529/12/2008

3. Dosage with metered valves :Reproducibility of dosage determined by:

»Assay

»Accurate weighing of filled container followed by dispensing several dosage.

containers again reweighed & diff. in wt. divided by no. of dosage dispensed gives average dose.

4. Net Contents :Tared cans placed on filling lines are reweighed & then difference in wt. is equal to net content.

In Destructive method : opening the container & removing as much of product possible.

Page 16: Quality control & evaluation of aerosol

M.Pharm I Sem,2008-09,GCP Aurangabad

1629/12/2008

5. Foam stability :Various Methods : » Visual Evaluation,

» Time for given mass to penetrate the foam,

» Time for given rod to fall which is inserted into the foam,

» Rotational Viscometer.

6.Partical Size Determination : Methods : » Cascade Impactor,

» Light Scattering Decay.

Page 17: Quality control & evaluation of aerosol

M.Pharm I Sem,2008-09,GCP Aurangabad

1729/12/2008

a). Cascade Impactor :Principle : Stream of particle projected through a series of nozzle & glass slides at high velocity, larger particle are impacted on low velocity stage , & smaller on higher velocity stage.

b). Light Scattering Decay :Principal : As aerosol settles under turbulent condition, the changes in the light of a Tyndall beam is measured.

Page 18: Quality control & evaluation of aerosol

M.Pharm I Sem,2008-09,GCP Aurangabad

1829/12/2008

D. Biological testing:

1.Therapeutic Activity : » For Inhalation Aerosols : is depends on the particle size.

» For Topical Aerosols : is applied to test areas & adsorption of therapeutic

ingredient is determined.

2.Toxicity : » For Inhalation Aerosols : exposing test animals to vapor

sprayed from Aerosol container.

» For Topical Aerosols : Irritation & Chilling effects are determined.

Page 19: Quality control & evaluation of aerosol

M.Pharm I Sem,2008-09,GCP Aurangabad

1929/12/2008

References:

“The Theory & Practice Of Industrial Pharmacy” by Leon Lachman, H.A.Liberman, Joseph Kanig, 3rd Edition, Varghese Pub., page no. 613-618.

Remington’s “The Science & Practice Of Pharmacy” 3rd Edition, Volume-I, page no.1014-1015.

Page 20: Quality control & evaluation of aerosol

M.Pharm I Sem,2008-09,GCP Aurangabad

2029/12/2008