QAV Technologies Sdn. Bhd. (616788-U) 116, Lintang Kg Jawa, NFIZ3, Taman Perindustrian Bayan Lepas, Mk 12, 11900, Penang. MALAYSIA. Tel No: 604 - 6438317 Fax No : 604 – 6438597 Test Report High Temperature Operation Test For U228 Head Lamp Product: Signature Park (LH& RH) Product Part #: PPFL7X-13B602-BC and PPFL7X- 13B603-BC Test Prime: Farahein Rahman Date Received: 26 Dec 2014 Date Perform: 30 Dec 2014 Report Number: QAV-0115-0160 Test Location: 116, Lintang Kg Jawa, NFIZ3, Taman Perindustrian Bayan Lepas, Mk 12, 11900, Penang, Malaysia. Customer: Philips Lumileds Lighting (Malaysia) Sdn. Bhd Address: Lebuh Kampung Jawa, FTZ Phase 3, 11900 Penang, Malaysia. ABSTRACT: This report contains the High Temperature Operation Test for the U228 Head Lamp LH&RH provided by Philips Lumileds Lighting (Malaysia) Sdn Bhd. Proprietary Information The information contained in this document is the property of QAV Technologies Sdn Bhd. Except as specifically authorized
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
QAV Technologies Sdn. Bhd. (616788-U)116, Lintang Kg Jawa, NFIZ3,
Taman Perindustrian Bayan Lepas,Mk 12, 11900, Penang. MALAYSIA.
Tel No: 604 - 6438317 Fax No : 604 – 6438597
Test Report
High Temperature Operation Test For U228 Head Lamp
Product: Signature Park (LH& RH) Product Part #: PPFL7X-13B602-BC and PPFL7X-13B603-BCTest Prime: Farahein RahmanDate Received: 26 Dec 2014Date Perform: 30 Dec 2014Report Number: QAV-0115-0160Test Location: 116, Lintang Kg Jawa, NFIZ3,
Taman Perindustrian Bayan Lepas, Mk 12, 11900, Penang, Malaysia. Customer: Philips Lumileds Lighting (Malaysia) Sdn. BhdAddress: Lebuh Kampung Jawa, FTZ
Phase 3, 11900 Penang, Malaysia.
ABSTRACT: This report contains the High Temperature Operation Test for the U228 Head Lamp LH&RH provided by Philips Lumileds Lighting (Malaysia) Sdn Bhd.
Proprietary Information
The information contained in this document is the property of QAV Technologies Sdn Bhd. Except as specifically authorized in writing by Philips Lumileds Lighting (Malaysia) Sdn Bhd., the holder of this document: (1) shall keep all information contained herein confidential and shall protect same in whole or in part from disclosure and dissemination to all third parties and (2) shall use same for operating and maintenance purposes only.
Prepared by: Farahein Rahman Date: 23 January 2015
1.0 Test Summary :
A total of 3 set U228 Head Lamp were subjected to low temperature operation test. Functional and visual light up test was done before and after test.
2.0 Test Objective:
The tests were done to verify that the component operates properly at low temperatures encountered during vehicle cold weather operation.
3.0 Test Specification:
Specification : CETP: 00.00-E-412
Lamp Voltage (V) Temperature (ºC) Duration (hrs)
Signature 13.5 -40 24
Park 13.5 -40 24
Table 1: Powered Thermal Cycle Parameter
4.0 Test Location:
Test Location : 116, Lintang Kg Jawa, NFIZ3, Taman Perindustrian Bayan Lepas, Mk 12, 11900, Penang, Malaysia.
Lab Temperature : 26.4°C-27.4°CLab Humidity : 42.1%RH – 48.5%RH
Page 2 of 6
5.0 Test Equipment
Picture 1: Thermal Cycling Chamber
Equipment : Programmable Thermal Cycling Chamber Manufacturer : ALP Technology Cal date : 17 June 2013Cal due date : 17 June 2014
Page 3 of 6
6.0 Test Setup and Procedures
Picture 2: Test Setup
1) Wear antistatic glove & wrist strap and check with the ESD meter before handling the units.
2) Verify all the test samples are passed function and visual check (13.5V, 23C) before proceed.
3) Ensure all the test samples are properly secure in the chamber by holder jig.
4) Ensure all the test samples are properly connected to the correct wire harness.
5) Set and run the chamber temperature profile according to each test item requirement as shown in Table 1.
6) Power up the test samples according to test requirement and check with the oscilloscope to ensure the on/off timing is correct as shown in Table 1.
7) Verify all the test samples are passed function and visual check (13.5V, 23C) after the duration according to Table 1 above.