PV-ezRack Cover for Isolator Bracket II Code-Compliant Planning and Installation Guide V1.0 Complying with AS/NZS 5033: 2014 AMDT 2: 2018
7

PV-ezRack Cover for Isolator Bracket II...PV-ezRack Cover for Isolator Bracket II Code-Compliant Planning and Installation Guide V1.0 Complying with AS/NZS 5033: 2014 AMDT 2: 2018

Feb 17, 2021

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
  • PV-ezRack Cover for Isolator Bracket IICode-Compliant Planning and Installation Guide V1.0 Complying with AS/NZS 5033: 2014 AMDT 2: 2018

  • Unit 1, 10 Duerdin St, Clayton VIC 3168, AustraliaTel: +61 3 9239 8088 Fax: +61 3 9239 8024E-mail: [email protected] www.clenergy.com.au

    01page of 05

    Introduction

    1. Introduction

    PV-ezRack Cover for Isolator Bracket II is specially designed for Isolator Bracket II, suitable for PV array AC/DC isolators.

    When correctly installed, the Isolator cover assembly with isolator bracket II is designed to function as a shroud to protect isolator and its enclosure from direct exposure to sunlight and rain as required by clause 4.3.3.3.2 of AS/NZS 5033:2014 Amdt 2: 2018. The isolator must have a suitable enclosure conforming to clause 4.3.3.3.1 of AS/NZS 5033:2014 Amdt 2: 2018. The isolator and its enclosure fit inside the shroud after assembly of isolator bracket II and the cover.

    Please review this guide thoroughly before installing PV-ezRack Cover for Isolator Bracket II.

    The installer is solely responsible for:

    • Complying with all applicable local or national building codes, including any that may supersede this manual;

    • Ensuring that PV-ezRack and other products are appropriate for the particular installation and the installation environment;

    • Using only PV-ezRack parts and installer- supplied parts as specified by the PV-ezRack project plan. (substitution of parts may void the warranty and invalidate the letter of certification);• Recycle according to the local relevant statutes;

    • Removal by reversing the installation process;

    • Ensure that there are no less than two professionals working on panel installation;

    • Ensure the installation of related electrical equipment is performed by licenced electricians;

    • Ensuring safe installation of all electrical aspects of the PV array. This includes adequate earth bonding of the PV array and PV-ezRack®

    components as required in AS/NZS 5033-2014 AMDT 2 2-2018.

    IntroductionTools &Component listInstallation Instruction

    010203

    List of Contents

  • Unit 1, 10 Duerdin St, Clayton VIC 3168, AustraliaTel: +61 3 9239 8088 Fax: +61 3 9239 8024E-mail: [email protected] www.clenergy.com.au

    02page of 05

    2.2 Components

    CO-IBII/240/100Cover for Isolator Bracket II

    Tools and Components

    2. Tools and Components2.1 Tools

    Power Tool(maximum torque ≥20 N·m , for

    M6 and M8 Hexagon Socket Screw)

    10mm SpannerMarker Pen Torque Wrench

    Tools

  • Unit 1, 10 Duerdin St, Clayton VIC 3168, AustraliaTel: +61 3 9239 8088 Fax: +61 3 9239 8024E-mail: [email protected] www.clenergy.com.au

    03page of 05

    Installation Instruction

    3. Installation Instructions

    3.1 Assemble the Cover for Isolator Bracket II and the Isolator Bracket II (part number: IBII/240/100) together as shown in Figures 1 and 2.

    3.2 In assembling, there could be interference between the bolt head of the Cover and the Bracket. Please open the Cover slightly to make the bolt head pass through as shown in Figures 3 and 4.

    3.3 Align the hole of L profile connecting piece with the elongated hole of the Isolator Bracket as shown in Figure 4.

    Figure 1

    Figure 2

    Figure 3

    Figure 4

  • Unit 1, 10 Duerdin St, Clayton VIC 3168, AustraliaTel: +61 3 9239 8088 Fax: +61 3 9239 8024E-mail: [email protected] www.clenergy.com.au

    04page of 05

    Installation Instruction

    3.4 Fasten the Cover and the Isolator Bracket II slightly as shown in Figure 5.

    3.5 Turn over the assembled Isolator Bracket and Cover and align both L profile connecting pieces at the same height in Figure 6.

    The holes of connecting pieces should position at the one end of elongated holes of the isolator bracket to make isolator cover and bracket nice fit together as shown in Figure 7.

    Fasten these two M6 bolts tightly with recommended torque of 8-10N·m

    Note: The bolt heads should be inside of isolator bracket to minimize the interference of bolts on isolator.

    Figure 5

    Figure 6

    Figure 7

  • Unit 1, 10 Duerdin St, Clayton VIC 3168, AustraliaTel: +61 3 9239 8088 Fax: +61 3 9239 8024E-mail: [email protected] www.clenergy.com.au

    05page of 05

    Installation Instruction

    3.6 Fasten two M6 bolts in Figure 8 with recommended torque of 5-6N·m to allow for optimal opening and closing of the isolator cover.

    3.7 Open the Cover to install the Isolator on the isolator bracket as shown in Figure 9.

    3.8 Fix Z-Modules, Bolts, and washers on the bottom elongated holes of the Isolator Bracket as shown in Figure 10.

    3.9 Install the Isolator Bracket along the Rails as shown in Figure 11.

    Note: Allow space above the Rail to open the isolator cover.

    Recommended torque for M8 bolts (with z modules) is 5-6N·m

    Figure 8

    Figure 9

    Figure 10

    Figure 11

  • Clenergy Australia 1/10 Duerdin Street, Clayton VIC 3168 AustraliaTel: +61 3 9239 8088 Fax: +61 3 9239 8024E-mail: [email protected] www.clenergy.com.au

    Clenergy China999-1009 Min’an Rd, Huoju Hi-tech Ind. Dev. ZoneXiang’an District 361101, Xiamen, Fujian, ChinaTel: +86 592 311 0088 Fax: +86 592 599 5028E-mail: [email protected] www.clenergy.com.cn

    Clenergy EMEAEsplanade 41, 20354 Hamburg, GermanyTel: +49 (0) 40 3562 389 00E-mail: [email protected]

    Clenergy JapanNittochi Yamashita Building 5th Floor23 Yamashita-cho, Yokohama, 231-0023 JapanTel: +81 45 228 8226 Fax: +81 45 228 8316E-mail: [email protected] www.clenergy.jp

    Clenergy Philippines145 Yakal St., San Antonio village, Makati City, PhilippinesTel: +63 977 8407240E-mail: [email protected] www.clenergy.ph

    Clenergy Thailand9/2, 5th Floor, Vorasin Building, Soi Yasoob 2, Viphavadee-RungsitRoad, Chomphon Sub-district, Chatuchak District, Bangkok 10900Tel: +66 63 228 0200, +66 81 969 5152E-mail: [email protected],[email protected]

    Clenergy Singapore24 Raffles Place #28-01 Clifford Centre Singapore 048621Tel: +65 9743 1425E-mail: [email protected]

    Clenergy VietnamTel: +86 592 3110095E-mail: [email protected]; [email protected]; [email protected]

    Worldwide network

    Clenergy Installation Guide-Cover for Isolator Bracket II 201910

    Warranty