KALDEWEI SPECIFICATIONS Recommended use Domestic, Hotel and Commercial Material 3.5mm Enamel Steel Colour availability White (other colour options available) Weight 46 kg Overflow Yes Plug and waste 40mm Pop-up Waste and overflow included Capacity 105L Fixing Hob Mounted, Built In, Undermounted, or Flush mounted. Sound-deadening pads are a standard inclusion. Installation Option Leg System #2006759 available for easy installation CLEANING RECOMMENDATIONS To see the complete KALDEWEI range go to www.reece.com.au/bathrooms PURO INSET BATH WITH END OVERFLOW We recommend the use of soapy water or approved cleaners. This product should not be cleaned with abrasive materials. Damage caused by any improper treatment is not covered by the product warranty. Refer to Warranty Conditions. 705 410 700 90 1600 1410 1180 32 65 552-572 420 310 580 410 100 214 52 52 435 60 Disclaimer: Products in this specification manual must by regulation be installed by licensed and registered trade people. The manufacturer/distributor reserves the right to vary specifications or delete models from their range without prior notification. Dimensions are nominal measurements only. Dimensions and set-outs listed are correct at time of publication however the manufacturer/distributor takes no responsibility for printing errors. Tech Page Version 1 Dimensions are nominal measurements only. page 1 of 4
4
Embed
PURO - Reece Group · PURO INSET BATH WITH END OVERFLOW 3. Push a suitable length of the tensioning belt onto the retaining bolt (a), engage the threaded hook (c) and tighten by hand
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
KALDEWEI
SPECIFICATIONSRecommended use Domestic, Hotel and Commercial
Material 3.5mm Enamel Steel
Colour availability White (other colour options available)
Weight 46 kg
Overflow Yes
Plug and waste 40mm Pop-up Waste and overflow included
Capacity 105L
Fixing Hob Mounted, Built In, Undermounted, or Flush mounted. Sound-deadening pads are a standard inclusion.
Installation Option Leg System #2006759 available for easy installation
CLEANING RECOMMENDATIONS
To see the complete KALDEWEI range go to www.reece.com.au/bathrooms
PURO INSET BATH WITH END OVERFLOW
We recommend the use of soapy water or approved cleaners.
This product should not be cleaned with abrasive materials.
Damage caused by any improper treatment is not covered by the product warranty. Refer to Warranty Conditions.
Höhe mit FüßenRandhöheAbstand Oberkante bis Mitte ÜberlauflochAbstand Wannenrand (Fuß) bis Mitte AblauflochDurchmesser ÜberlauflochDurchmesser AblauflochAbstand Fußseite Wannenrand bis Mitte FußAbstand zwischen den Füßen
a
cd
efghijklmno
Innere Länge (oben)Innere Länge (unten)Innere Breite (oben)Innere Breite (unten)
Fußbreite max. pRandbreite (Fußseite, Kopfseite, Längsseite)* s ; s ;
M 1:20 Badewanne Modell-Nr.:
b
Abstand Mitte Ab- bis Mitte Überlaufloch u
Gewicht der Rohwanne (ohne Zubehör) in kgGewicht der emaillierten Wanne in kg
Wasserinhalt bis Überlauf in ltr.
AntislipVollantislip
s1 2 3
2562.00011700x750170075042015101280620460*554-568
6532
310525244575047090,100,60*
652
214
46,2207
50,0
2563.00011800x800180080042016101380670510*553-563
6532
310525246082052090,100,60*
653
214
49,2235
53,6348x348 396x396924x348 1020x396
2583.00011600x700160070042014101180580410x-x
6532
3105252xxx90,100,60
683
214
xx
x
x
2587.00011700x700170070042015101280580410x-x
6532
3105252x
x90,100,60
687
214
xx
xx xx x
2591.00011700x800170080042015101280680460x-x
6532
3105252xxx90,100,85
691
214
xx
xxx
705 410
70090
1600
1410
1180
32
65
552-
572
420
310
580
410
100
214
52
52
435
60
Disclaimer: Products in this specification manual must by regulation be installed by licensed and registered trade people. The manufacturer/distributor reserves the right to vary specifications or delete models from their range without prior notification. Dimensions are nominal measurements only. Dimensions and set-outs listed are correct at time of publication however the manufacturer/distributor takes no responsibility for printing errors.
Tech Page Version 1
Dimensions are nominal
measurements only.
page 1 of 4
INSTALLATION INSTRUCTIONS
KALDEWEIPURO INSET BATH WITH END OVERFLOW
AUSTRALIAN BATH & SHOWER FLOOR INSTALLATION
Australian Standard 2023/1995 Section 1.5 specifies, “A built-in bath shall be provided with a tiling flange or bead not less than 10mm in height”.
When handling steel enamel baths, care must be taken that they are treated correctly. This applies to their transport, unpacking and installation.
Kaldewei recommends that baths be fitted during the final installation and that the bath be covered until all the building work has been completed.
This bath has been supplied with sufficient high impact rigid PVC modified grade material to allow, where necessary, for the bath to be flashed along the full length and ends to conform with the Australian standard.
This clip on material should be cut to the required lengths, mitred at the corners, and the area where the flashing material and the rim of the bath meet, should be filled with a mould-resistant Sanitary Grade sealant.
When the bath is installed, the minimum distance from the outside edge of the flange to the finished edge of the tiles shall be 10mm. The exposed area of the flange shall have continuous fall to the inside of the bath.
BATH OR SHOWER TRAY
FLEXIBLE MASTIC SEALANTTILE ADHESIVE
STUD OR MASONRY
WALL
PVC TILE TRIM
TILES
SUPPORT BATTEN
page 2 of 4
Plumbers, please ensure a copy of the installation instructions is left with the end user for future reference
OVERFLOW INSTALLATION INSTRUCTIONS
KALDEWEIPURO INSET BATH WITH END OVERFLOW
1. 2.
3. 4.
5. 6.Part Codes Description
23-5705605 KLUDI finish set for overflow
23-7050405-00 KLUDI plug (only)
AS/NZS 3718WMKA 00313
page 3 of 4
Plumbers, please ensure a copy of the installation instructions is left with the end user for future reference
LEG SYSTEM INSTALLATION INSTRUCTIONS
KALDEWEIPURO INSET BATH WITH END OVERFLOW
3. Push a suitable length of the tensioning belt onto the retaining bolt (a), engage the threaded hook (c) and tighten by hand using the nut on the base.
1.
Place the bath with its packaging upside down.
2.
Slot the arm straps of the bath cradle (b) onto the lugs (a) on the base of the bath.
b a
c
a
4.
Turn over bath, align with the help of a spirit level by turning the screw and tighten the locknut (d). With the use of the Kaldewei sound insulation set, and provided installation is effected properly, the requirements of DIN 4109/A1 are fulfilled.
Baths must also be mounted with bath anchors (not included in the scope of delivery).
d
a
page 4 of 4
Plumbers, please ensure a copy of the installation instructions is left with the end user for future reference