Operating InstructionsBedienungsanleitung Manuel
d‘utilisation
PTB 14 ATEX 2023 X, IECEx PTB 14.0049XSolenoid coil Type AC10
Magnetspule Typ AC10 Bobine magnétique Type AC10
Device with II 2G/D Ex approval Geräte mit II 2G/D Ex Zulassung
Appareils avec mode de protection II 2G/D Ex
-
We reserve the right to make technical changes without
notice.Technische Änderungen vorbehalten.Sous réserve de
modifications techniques.
© 2014-2016 Bürkert Werke GmbH
Operating Instructions 1601/02_EU-ML_00810392 / Original DE
-
3
1
OperatinginstructiOn...................................................................41.1
Definitionofterms/abbreviation...........................................
41.2
Symbols.......................................................................................
4
2
authOriseduse......................................................................................52.1
Explosionprotectionapproval................................................
5
3
BasicsafetyinstructiOns..........................................................6
4
generalinfOrmatiOn........................................................................74.1
Contactaddresses...................................................................
74.2
Warranty......................................................................................
74.3
Informationontheinternet......................................................
7
5
prOductdescriptiOn........................................................................85.1
Design..........................................................................................
85.2
Solenoidcoilwithcableoutlet...............................................
95.3
Solenoidcoilwithterminalbox...............................................
9
6 applicatiOncOnditiOnsOfthedevices....................... 106.1
Specialconditions...................................................................106.2
Operatingconditions..............................................................106.3
Operatingtemperaturerange...............................................11
7
technicaldata.....................................................................................117.1
Safetyinstructions...................................................................117.2
Conformity.................................................................................117.3
Standards..................................................................................117.4
Typelabelforexplosions-riskareas....................................127.5
Electricaldataforsolenoidcoilswithcableoutlet..........14
7.6
Electricaldataforsolenoidcoilswithterminalbox..........15
8
accessOries...........................................................................................168.1
Cableglandforterminalbox.................................................168.2
Externalgroundingconnectionforterminalbox...............16
9
installatiOnandremOval.........................................................
179.1
Installation.................................................................................179.2
Electricalconnection..............................................................189.3
Removal.....................................................................................19
10
start-up......................................................................................................20
11 maintenance,repair,trOuBleshOOting......................
2011.1
Maintenancework...................................................................2011.2
Repair.........................................................................................2011.3
Troubleshooting.......................................................................20
12
transpOrtatiOn,stOrage,dispOsal................................
21
Contents
english
PTB 14 ATEX 2023 X
-
4
Operating Instruction
1 OPErATIng
InsTruCTIOnTheoperatinginstructionsdescribetheentirelifecycleofthedevice.Keep
these instructions in a location which is easily accessible
toeveryuserandmaketheseinstructionsavailabletoeverynewownerofthedevice.
Operatinginstructioncontainimportantinformation.▶
Readtheoperatinginstructionscarefullyandfollowthesafetyinstructionsinparticular.
▶ Operatinginstructionsmustbeavailabletoeachuser.▶
Theliabilityandwarrantyforthedevicearevoidiftheoperatinginstructionsarenotfollowed.
1.1 Definition of terms / abbreviation
Intheseinstructions,theterm“device”alwaysreferstothesolenoidcoilAC10.
Intheseinstructions,theabbreviation“Ex”alwaysrefersto“potentiallyexplosive”.
1.2 symbols
Danger!
Warnsofanimmediatedanger.▶
Failuretoobservethewarningmayresultinafatalorseriousinjury.
Warning!
Warnsofapotentiallydangeroussituation.▶ Failure toobserve
thewarningmay result inserious injuriesordeath.
Caution!
Warnsofapossibledanger.▶
Failuretoobservethiswarningmayresultinamoderateorminorinjury.
note!
Warnsofdamagetoproperty.
Importanttipsandrecommendations.
Referstoinformationintheseoperatinginstructionsorinotherdocumentation.
▶ designatesaninstructiontopreventrisks.→
designatesaprocedurewhichyoumustcarryout.
english
PTB 14 ATEX 2023 X
-
5
Authorised use
2 AuThOrIsED usE
unauthorizeduseofthesolenoidcoilac10maybedangeroustopeople,nearbyequipmentandtheenvironment.
▶
ThesolenoidcoilAC10isusedtoactivatevalveswhichcontrolthegaseousorliquidmedia.
▶
AvalvecontrolledbythesolenoidcoilAC10maybeusedsolelyforthemediaspecifiedinthedatasheetandforuseinexplosiongroupIICcategory2Gand/orexplosiongroupIIICcategory2G,andtemperatureclassT4,T5orT6(refertothespecificationsonthetypelabelforexplosion-riskareas).
▶
Thesolenoidcoilmaybeusedonlyfortheapplicationsdesignatedinchapter“6Applicationconditionsofthedevices”andincon-junctionwiththird-partydevicesandcomponentsrecommendedandauthorizedbyBürkert.
▶
TheappliedprotectionclassisencapsulationEx“m”forcoilswithcableconnection.
▶ The ignitionprotectiontypefor
theoptionallymountedterminalboxis“e”forgasand“t”fordust.
▶ Thefaultlessandreliableoperationofthesystemassumescor-rect
transportation, correct storage and installation as well
ascarefuloperationandmaintenance.Anyotheruseisregardedasunauthorized.Bürkertisnotliableforanyresultingdamage.Theuseralonebearstherisk.
▶ Onlyusethedeviceforitsintendedpurpose.
2.1 Explosion protection approval
TheexplosionprotectionapprovalisonlyvalidifyouusethemodulesandcomponentsauthorizedbyBürkert,asdescribedintheseoper-atinginstructions.
ThesolenoidcoilAC10maybeusedonly incombinationwith thevalve
types releasedbyBürkert,otherwise
theexplosionprotectionapprovalwillbeterminated.
Ifyoumakeunauthorizedchangestothesystem,themodulesorcom-ponents,theexplosionprotectionapprovalwillalsobevoid.
EC-typeexaminationcertificateandIECExcertificate
SolenoidcoilAC10: PTB14ATEX2023X;IECExPTB14.0049X
Terminalbox: PTB15ATEX1011U;IECExPTB15.0037U
wereissuedby:
PTB(PhysikalischTechnischeBundesanstalt)Bundesallee10038116Braunschweig
ThePTB(CE0102)auditsthemanufacture.
TheECTypeExaminationCertificateisavailableonlineat:www.burkert.com
english
PTB 14 ATEX 2023 X
http://burkert.com/
-
6
Basic safety instructions
3 BAsIC sAfETy InsTruCTIOns
Thesesafetyinstructionsdonotmakeallowanceforany
•
Contingenciesandeventswhichmayariseduringtheinstallation,operationandmaintenanceofthedevices.
•
Localsafetyregulations–theoperatorisresponsibleforobservingtheseregulations,alsowithreferencetotheinstallationpersonnel.
danger–highpressure.▶
Beforelooseningthelinesandvalves,turnoffthepressureandventthelines.
riskofelectricshock.▶
Beforereachingintothedevice,switchoffthepowersupplyandsecuretopreventreactivation!
▶ Observeapplicable accidentprevention andsafety
regulationsforelectricalequipment!
riskofburnsandriskoffireifusedduringlong-termoperationthroughhotdevicesurface.
Thesolenoidcoilcangetveryhotduringlong-termoperation.▶
Keepthedeviceawayfromhighlyflammablesubstancesandmediaanddonottouchthedevicewithbarehands.
riskofexplosion.
Thesolenoidcoilandvalvebodyformaclosedsystemafterinstallation.Whenusedinexplosion-riskareas,thereisariskofexplosionifthesystemisopenedintheoperatingstate.
▶
Donotremoveoropenthesystemduringoperation.riskofexplosionduetoelectrostaticdischarge.
Intheeventofasuddendischargefromelectrostaticallychargeddevicesorindividuals,thereisariskofanexplosionintheexplosion-riskarea.
▶
Takesuitablemeasurestoensurethatnoelectrostaticdischargescanbuildupintheexplosion-riskarea.
▶
Donotusethedeviceinareaswheretherearepowerfulcharge-generatingprocesses,mechanicalreamingandcuttingprocesses,thesprayingofelectrons(e.g.inthevicinityofelectrostaticcoatingequipment)aswellaspneumaticallyconveyeddust.
▶
Cleanthedevicesurfacebygentlywipingitwithadamporanti-staticclothonly.
toavoidtheriskofexplosion,thefollowingmustbeobservedforoperationinexplosion-riskareas:
▶
Informationonthetemperatureclass,ambienttemperature,degreeofprotectionandvoltageonthetypelabelforexplosion-riskareas.
▶
Installation,operationandmaintenancemayonlybeperformedbyqualifiedspecialists.
▶
Theapplicablesafetyregulations(includingnationalregulations)aswellasgeneraltechnicalstandardsmustbeobservedduringsetupandoperation.
english
PTB 14 ATEX 2023 X
-
7
General information
▶ Repairsmayonlybeperformedbythemanufacturer.▶ The device must
not be exposed to any mechanical
and/orthermalloadswhichexceedthelimitsspecifiedintheoperatinginstructions.
▶ Beforeopeningtheterminalbox,disconnectthepowersupply.
generalhazardoussituations.
Topreventinjury,ensure:▶
Securesystem/equipmentagainstunintentionalactivation.▶
Observethedirectionofflowduringinstallation.▶ After an interruption
in thepower supply or pneumatic supply,ensure that theprocess is
restarted in adefinedor controlledmanner.
▶ Don’tusethedeviceasaleverwhenscrewingthevalveintotheline.
4 gEnErAl InfOrmATIOn
4.1 Contact addresses
germany
BürkertFluidControlSystemsSalesCenterChristian-Bürkert-Str.13-17D-74653IngelfingenTel.+49(0)7940-1091111Fax+49(0)7940-1091448E-mail:[email protected]
international
Contact addressescanbe foundon the finalpagesof
theprintedoperatinginstructions.
AndalsoontheInternetat:www.burkert.com
4.2 Warranty
ThewarrantyisonlyvalidifthesolenoidcoilAC10isusedasintendedinaccordancewiththespecifiedapplicationconditions.
4.3 Information on the internet
OperatinginstructionsanddatasheetsforBürkertproductsareavailableonlineat:www.burkert.com
english
PTB 14 ATEX 2023 X
http://www.buerkert.de/DEU/56.htmlhttp://burkert.com/
-
8
Product description
5 PrODuCT DEsCrIPTIOn
5.1 Design
componentsofthesolenoidcoilac10:
Bracket
Connectioncable
componentsofthevalve:
Nut
Coreguidetube
Valvebodywithportconnection
Coilhousing
Unionnut
Fig. 1: Solenoid coil Type AC10 with cable
outletValvebodywithportconnection
Coreguidetube
Nut
componentsofthevalve:
componentsofthesolenoidcoilac10withterminalbox:
Coilhousing
Bracket
Terminalbox
Screw
Circlip
Lockscrew
Washer
Ringcablelugwithsupplycable
Fig. 2: Solenoid coil Type AC10 with terminal box
english
PTB 14 ATEX 2023 X
-
9
Product description
5.2 solenoid coil with cable outlet
ThesolenoidcoiltypeAC10isanelectromagneticvalveactuatorforvariousBürkertvalves.Asaso-calledtop-mountedcoil,itisseparated100%fromthevalve.Thevalveisaclosedsystemevenifthecoilisremoved.
Thesolenoidcoilconsistsof:
• coilwinding,
• coilhousing(madefromepoxy),
• electricalconnectioncable,
• bridgerectifier.
Alternatingcurrentordirectcurrentcontrolispossible.
ThesolenoidcoiltypeAC10isavailableinarangeofratingsdistributedacross2framesizes.Theinterfacebetweenthecoilandvalveisiden-ticalforbothframesizes.
Thecoilisplacedoverthecoreguidetubeofthevalveandattachedwithanut.Itispositivelylockedtopreventturningrelativetothevalve.
Theelectricalconnectioncableexitsperpendicular to thecoil
axis.Thecableispermanentlyintegratedinthecoil.Theunionnutisnotdesignedtoberemoved.
Anelectricalcontactismadebetweenthemetalcomponentsofthevalveandthecoilattheinterfacebetweenthecoilandthevalve.Allmetalcomponentsmustbegroundedviatheprotectiveconductorintheconnectioncable.
5.3 solenoid coil with terminal box
Thedesignofthesolenoidcoil is
identicaltothedescriptionunder“5.2”, however a terminal box is also
installed here (see “Fig. 2”).The terminal box is certified with
the Type Examination
CertificatePTB15ATEX1011UorIECExPTB15.0037U.
The cable outlet direction can be selected according to the
orderrequirements. The outlet direction can be changed
subsequently,howeverthisrequiresaspecialtool1).Optionallyaconnectionsetisenclosedforadditionalpotentialequalization;todothis,observethespecificationsinchapter“8.2”.
1) To do this, please contact your local Bürkert
representative.
english
PTB 14 ATEX 2023 X
-
10
Application conditions of the devices
6 APPlICATIOn COnDITIOns Of ThE DEvICEs
6.1 special conditions
6.1.1 Avoiding build-up of electrostatic charge
Warning!
riskofexplosionduetoelectrostaticdischarge.
Intheeventofasuddendischargefromelectrostaticallychargeddevicesorindividuals,thereisariskofanexplosionintheexplosion-riskarea.
▶
Takesuitablemeasurestoensurethatnoelectrostaticdischargescanbuildupintheexplosion-riskarea.
▶
Donotusethedeviceinareaswheretherearepowerfulcharge-generatingprocesses,mechanicalreamingandcuttingprocesses,thesprayingofelectrons(e.g.inthevicinityofelectrostaticcoatingequipment)aswellaspneumaticallyconveyeddust.
▶
Cleanthedevicesurfacebygentlywipingitwithadamporanti-staticclothonly.
6.1.2 short-circuit protection
Afuse(max.3xIbinaccordancewithIEC60127-2-1)correspondingtotheratedcurrentmustbeconnectedaheadofeverysolenoidtoprotectagainstshortcircuits.
•
Ifthemagnethasverylowratedcurrents,thefusewiththelowestcurrentvalueaccordingtothestatedIECstandardisadequate.Thisfusemustbeconnectedseparatelyupstream.
• The rated fusevoltagehas tobe thesameasorhigher than
thespecifiednominalvoltageofthesolenoid.Theratedfusevalue
isspecifiedonthetypelabel(seechapter“7.4”).
•
Theinterruptionratingofthefuselinkmustbethesameasorhigherthanthemaximumshort-circuitcurrenttobeacceptedattheinstal-lationsite(usually1500A).
6.1.3 Block assembly
Valveblocksarepreferablymadeupsothatallunitshavethesamecoilpowerconsumption.Ifdifferentcoilpowerconsumptionvaluesareusedinasinglevalveblock,thenthetechnicaldataforthecoilwiththehighestpowerratingmustbeusedtodeterminethetemperatureclass.Inthiscasetheambienttemperaturemustbenohigherthan+40°C.
Thecoilwithterminalboxcannotbeconstructedasablockassembly.
6.2 Operating conditions
Thevalveprovidesacoolingfunctionforthesolenoidcoil.Thesolenoidcoilmaynotbeoperatedwithoutavalve.Thevalvebodymustmeetthefollowingrequirements:
• MaterialMetal(brass,aluminium,stainlesssteel)orpolyamide
• Minimumdimensions32mmx32mmx10mm
english
PTB 14 ATEX 2023 X
-
11
Technical data
Alargervalvebodywithahigherheat-dissipatingcapabilitycanbeusedatanytime.
Thesolenoidcoilsdesignedforindividualinstallationmaynotbeusedforblockassembly.
Thesolenoidcoilsdesignedforblockassemblyaresuitableforbothblockassemblyandforindividualinstallation.
6.3 Operating temperature range
Observetheoperatingtemperaturerangespecifiedintheelectricaldataforalltypes.
7 TEChnICAl DATA
7.1 safety instructions
Danger!
riskofexplosion.
Dangerous situations can result if the technical safety data
andvaluesspecifiedonthetypelabelaren’tobservedorcannotbemet.
▶
Thedegreeofprotectionandtemperatureclassforuseofthedevicemustbeobserved.
Exceedingthevoltagespecifiedonthetypelabelcreatesasafetyhazardsinceitcanleadtooverheatingofthedevice!
▶
Don’tconnectthedevicetoahighervoltagethanthatspecifiedonthetypelabel.
7.2 Conformity
The solenoid coil Type AC10 is compliant with the EC
DirectivesaccordingtotheECDeclarationofConformity.
7.3 standards
TheappliedstandardswhichareusedtodemonstratecompliancewiththeECDirectivesarelistedintheECtypetestcertificateand/ortheECDeclarationofConformity
english
PTB 14 ATEX 2023 X
-
12
Technical data
7.4 Type label for explosions-risk areas
7.4.1 Identification of the solenoid coil
Typelabelwithvalvespecifications
solenoidcoilac10withsamplevalveandthepositionsofthetypelabel:
TypelabelwithsolenoidcoilAC10
specifications
2023 XT4T130°C
0049 XT4T130°C
5 PX227 8 A
274833
12
34
56789
10
Fig. 3: Location and description of the explosion type label
legend:
position description
1 ATEX,Certificateissuerandcertificatenumber
2 ATEX,Explosionprotectionlabelling
3 IECEx,Certificateissuerandcertificatenumber
4 IECEx,Explosionprotectionlabelling
5 TypelabelwithEx-code(last4digits)
6 Nominalvoltage,nominalpower,nominalfusevalue
7 Ambienttemperaturerange
8 Serialnumber
9 Dateofmanufacture
10 Identificationnumber
english
PTB 14 ATEX 2023 X
-
13
Technical data
7.4.2 Identification of the terminal box
note!
Attachmentoftheterminalboxchangestheignitionprotectiontype.
solenoidcoilac10withterminalboxwithsamplevalveandthepositionsofthetypelabel:
12
34
56789
10
2023 XT4T130°C
0049 XT4T130°C
5 PX22 JA127 8 A
286863
ebtb
ebtb
Fig. 4: Location and description of the explosion type
labels
legend:
position description
1 ATEX,Certificateissuerandcertificatenumber
2 ATEX,Explosionprotectionlabelling
3 IECEx,Certificateissuerandcertificatenumber
4 IECEx,Explosionprotectionlabelling
5 TypelabelwithEx-code(last4digits)
6 Nominalvoltage,nominalpower,nominalfusevalue
7 Ambienttemperaturerange
8 Serialnumber
9 Dateofmanufacture
10 Identificationnumber
english
PTB 14 ATEX 2023 X
-
14
Technical data
7.5 Electrical data for solenoid coils with cable outlet
7.5.1 Coils for individual installation
Universalcurrent,availablenominalvoltagesfrom12Vto240V,frequency0to60Hz
code Overallwidthin
mm
tempera-tureclass
ambienttem-peraturerange
in°c
nominalpowerinW
PX22 32 T4 -40to+60 7.0
PX23 40 T4 -40to+60 9.0
PX25 32 T6 -40to+40 3.0
PX26 40 T6 -40to+60 1.8
PX27 32 T6 -40to+50 2.25
PX29 32 T5 -40to+60 3.0
PX31 32 T4 -40to+80 3.0
7.5.2 Coils for block assembly
Danger!
riskofexplosionduetooverheating!▶
Don’tconnectthedevicetoahighervoltagethanthatspecifiedonthetypelabel.
Universalcurrent,availablenominalvoltagesfrom12Vto240V,frequency0to60Hz
code Overallwidthin
mm
tempera-tureclass
ambienttem-peraturerange
in°c
nominalpowerinW
PX24 32 T4 -40to+40 7.0
PX28 32 T6 -40to+40 2.25
PX30 32 T5 -40to+50 3.0
7.5.3 Technical data of the connection cable
Material2): Electronbeamcross-linkedpolyolefincopolymer
Operatingtemperaturerange2):
-55°Cto+145°Cforfixedinstallation
Minimumbendingradius2): 4xouterdiameterforfixedinstallation
Outsidediameter2): 6.2mm
Design/function: 3xstrandedcopperwire0.75mm²/LNPE
HalogenfreeinaccordancewithIEC60754-1
TestedaccordingtoDINEN13617-1foruseingasolinepumps
2) Specifications as per the manufacturer
english
PTB 14 ATEX 2023 X
-
15
Technical data
Wireassignment:
Wirecolor assignment
green-yellow Protectiveconductor
brown Coilconnection1
blue Coilconnection2
7.6 Electrical data for solenoid coils with terminal box
Cableglandisnotincludedinthescopeofdeliveryandisoptionallyavailableasanaccessory(seeChapter“8”).
7.6.1 Coils for individual installation
Universalcurrent,availablenominalvoltagesfrom12Vto240V,frequency0to60Hz
code Overallwidthin
mm
tempera-tureclass
ambienttem-peraturerange
in°c
nominalpowerinW
PX22+JA12 32 T4 -40to+60 7.0
PX23+JA12 40 T4 -40to+60 9.0
PX25+JA12 32 T6 -40to+40 3.0
PX26+JA12 40 T6 -40to+60 1.8
PX27+JA12 32 T6 -40to+50 2.25
code Overallwidthin
mm
tempera-tureclass
ambienttem-peraturerange
in°c
nominalpowerinW
PX29+JA12 32 T5 -40to+60 3.0
PX31+JA12 32 T4 -40to+60 3.0
english
PTB 14 ATEX 2023 X
-
16
Accessories
8 ACCEssOrIEs
8.1 Cable gland for terminal box
Suitablecableglandsareavailableforuseoftheterminalbox.
Cablegland isnot included in thescopeofdeliveryof
thesolenoidcoilwith
terminalboxandmustbeorderedsepa-rately.Cableglands
fromothermanufacturersmayalsobeusediftheyaredesignedfortheinstallationlocationandcanbeinstalledcorrectly.Notethattheapplicationtemperatureofthecableglandmustbemin.15Kabovethemax.ambienttemperature.
material clampingrange[mm]
Operatingtemperature
Ordernumber
certificatenumber
Plastic 7-13-40to+75°C
773277 3)
Brass 6-13 773278 4)
material ip-pro-tection
dustidentification
gasidentification
PlasticIP66 II2DExtbIIICDb II2GExeIICGb
Brass
3) PTB 13 ATEX 1015X; IECEx PTB 13.00034X4) PTB 04 ATEX 1112X;
IECEx PTB 13.00027X
8.2 External grounding connection for terminal box
If solenoid coils feature a terminal box, connection terminals
areenclosedfortheexternalgroundingconnection.
If thepotentialequalization isnot tobeconnectedbyapipelineorby
theuseofaplastic fitting, theconnectioncanbemadevia
theexternalgroundingconnection.Itsuseisthereforeoptionalandmustbeassessedbytheoperator.
Theconnectioncapacityoftheringcablelugis4-6mm2.Thecon-nectionismadeasshownin“Fig.7”.
english
PTB 14 ATEX 2023 X
-
17
Installation and removal
9 InsTAllATIOn AnD rEmOvAl
Danger!
danger–highpressure.▶
Beforelooseningthelinesandvalves,turnoffthepressureandventthelines.
riskofelectricshock.▶
Beforereachingintothedevice,switchoffthepowersupplyandsecuretopreventreactivation!
▶ Observeapplicable accidentprevention andsafety
regulationsforelectricalequipment!
riskofburnsorriskoffireifusedduringlong-termoperationthroughhotdevicesurface.
▶
Keepthedeviceawayfromhighlyflammablesubstancesandmediaanddonottouchthedevicewithbarehands.
riskofshort-circuitduetodamagedconnectioncable.▶
Thecoilconnectioncablehavetobefixedandprotectedagainstdamage.
riskofexplosion.
Thesolenoidcoilandvalvebodyformaclosedsystemafterinstallation.Whenusedinexplosion-riskareas,thereisariskofexplosionifthesystemisopenedintheoperatingstate.
▶ Thesystemmustnotbedisassembledduringoperation.
Danger!
riskofexplosionduetoelectrostaticdischarge.
Intheeventofasuddendischargefromelectrostaticallychargeddevicesorindividuals,thereisariskofanexplosionintheexplosion-riskarea.
▶
Takesuitablemeasurestoensurethatnoelectrostaticdischargescanbuildupintheexplosion-riskarea.
▶
Donotusethedeviceinareaswheretherearepowerfulcharge-generatingprocesses,mechanicalreamingandcuttingprocesses,thesprayingofelectrons(e.g.inthevicinityofelectrostaticcoatingequipment)aswellaspneumaticallyconveyeddust.
▶
Cleanthedevicesurfacebygentlywipingitwithadamporanti-staticclothonly.
Warning!
riskofinjuryfromimproperinstallation.
▶
Installationmaybecarriedoutbyauthorizedtechniciansonlyandwiththeappropriatetools.
▶ Securesystemfromunintentionalactivation.▶
Followingassembly,ensureacontrolledrestart.
9.1 Installation
Detailed installation instructions canbe found in theoper-ating
instructions of the respective valve and/or online
at:www.burkert.com
english
PTB 14 ATEX 2023 X
http://burkert.com/
-
18
Installation and removal
9.2 Electrical connection
Danger!
riskofelectricshock.▶
Beforereachingintothedevice,switchoffthepowersupplyandsecuretopreventreactivation.
▶ Observeapplicable accidentprevention andsafety
regulationsforelectricalequipment.
Thereisariskofelectricshockifthereisnoelectricalcontactbetweenthemetalpartsofthevalveandtheprotectiveconductorofthecoil.
▶ Alwaysconnecttheprotectiveconductor.▶
Testforcontinuitybetweentheprotectiveconductorofthecoilandthecoreguidetubeofthevalve.
ifsolenoidcoilsfeatureaterminalbox,alsoobservethefollowing:
▶ Insertpermanentlyinstalledcablesandlinesonly.▶
Useasuitablecableand
lineentry(seechapter“8”).Observespecificationsintheenclosedoperatinginstructions.
▶
Intheterminalboxconnectonlywireswhichhavearatedconnec-tionbetween0.75mm2and1.5mm2.
▶ Tightenterminalscrewsto1.2Nm.▶
Lockhousingcoverproperly.Tightenlockscrewto2Nm.▶
Checkcontinuityoftheprotectiveconductorconnection.▶
Beforeopeningthehousingcover,disconnectthepowersupply.▶
Connectmaximumtwoconductorstoeachterminalpoint.
▶
Temperatureresistanceofthecablemustbemin.15Kabovethemax.ambienttemperature.
▶ Whenusingflexiblelines,usewireendferrules.
9.2.1 solenoid coils with cable outlet
TheconnectioncableisencapsulatedwiththesolenoidcoilTypeAC10andcannotberemoved.Observetheindicatedvoltageaccordingtothetypelabel.
9.2.2 solenoid coils with terminal box
position terminalassignment
Protectiveconductorconnection
1Neutralconductorcon-nection/-Pol
2Phaseconnection/+Pol
green-yellow
blue
brown
Fig. 5: Terminal box
FuseofType1058mustnotbeusedinthepotentiallyexplosivearea.
english
PTB 14 ATEX 2023 X
-
19
Installation and removal
Screw
Circlip
Clampingbracket
Connectionline
Washer
Fig. 6: Protective conductor connection
Screw
Circlip
Washer
Washer
Ringcablelugwithsupplyline
Fig. 7: Connection of external potential equalization
9.3 removal
Danger!
danger–highpressure.▶
Beforelooseningthelinesandvalves,turnoffthepressureandventthelines.
riskofelectricshock.▶
Beforereachingintothedevice,switchoffthepowersupplyandsecuretopreventreactivation!
▶ Observeapplicable accidentprevention andsafety
regulationsforelectricalequipment!
Warning!
riskofinjuryfromimproperremoval.
▶
Removalmaybecarriedoutbyauthorizedtechniciansonlyandwiththeappropriatetools.
riskofinjuryduetomediaescapingfromleakyconnections.▶
Sealtheconnectionlinescarefully.
→ Separatetheelectricalconnections.→
Separatethevalvebodyfromthepipeline.
note!
malfunctionsduetodirt!•
RemovetheoldPTFEtapefromtheconnectionsduringre-installs.
Taperesiduemustnotgetintothepipeline.
english
PTB 14 ATEX 2023 X
-
20
Start-up
10 sTArT-uP
Warning!
riskofinjuryfromimproperoperation.
Improperoperationmayresultininjuriesaswellasdamagetothedeviceandtheareaaroundit.
▶ Beforestart-up,ensurethattheoperatingpersonnelarefamiliarwith
and completely understand the contents of the
operatinginstructions.
▶ Observethesafetyinstructionsandintendeduse.▶
Onlyadequatelytrainedpersonnelmaystartuptheequipmentorthedevice.
Beforestartingupthedevice,ensurethat:
→ thedevicehasbeeninstalledcorrectly,→
theconnectionhasbeenmadeproperly,→ thedeviceisnotdamaged.
11 mAInTEnAnCE, rEPAIr, TrOuBlEshOOTIng
11.1 maintenance work
ThesolenoidcoilAC10aremaintenance-freewhenoperatedundertheconditionsdescribedinthismanual.
11.2 repair
Danger!
dangerduetoimproperrepairs.
Thesafetyand functionalityof theAC10coil
andcorrespondingsolenoidvalvefollowingarepairareonlygiveniftherepairworkwasperformedbythemanufacturer.
▶ Onlyhavethedevicerepairedbythemanufacturer.
11.3 Troubleshooting
Ifmalfunctionsoccur,ensurethat:
→ thedevicehasbeeninstalledcorrectly,→
theconnectionhasbeenmadeproperly,→ thedeviceisnotdamaged,→
thevoltageandpressurehavebeenswitchedon,→ thepipelinesarefree.
english
PTB 14 ATEX 2023 X
-
21
Transportation, Storage, Disposal
12 TrAnsPOrTATIOn, sTOrAgE, DIsPOsAl
note!
transportdamages!
Inadequatelyprotectedequipmentmaybedamagedduringtransport.
•
Duringtransportationprotectthedeviceagainstwetanddirtinshock-resistantpackaging.
•
Avoidexceedingordroppingbelowtheallowablestoragetemperature.
incorrectstoragemaydamagethedevice.
• Storethedeviceinadryanddust-freelocation!
• Storagetemperature:-40...+55°C.
damagetotheenvironmentcausedbydevicecomponentscontaminatedwithmedia.
•
Ensurethedeviceandpackagingaredisposedofinanenviron-mentallysoundmanner.
•
Observeapplicableregulationsrelatingtorefusedisposalandtheenvironment.
english
PTB 14 ATEX 2023 X
-
22
Transportation, Storage, Disposal
english
PTB 14 ATEX 2023 X
-
www.burkert.com