Top Banner
PT. GlobalNine Indonesia, Niaga Kalimas Blok-A No.5 Bekasi Timur, Bekasi Phone: +62 21 8835 7506 / Fax +62 21 8835 7507, Web: www.global9-ind.com PRESENTED BY: NetMACS II TM
13

PT. GlobalNine Indonesia, Niaga Kalimas Blok-A No.5 Bekasi Timur, Bekasi Phone: +62 21 8835 7506 / Fax +62 21 8835 7507, Web: PRESENTED.

Mar 28, 2015

Download

Documents

Kurtis Arnott
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: PT. GlobalNine Indonesia, Niaga Kalimas Blok-A No.5 Bekasi Timur, Bekasi Phone: +62 21 8835 7506 / Fax +62 21 8835 7507, Web:  PRESENTED.

PT. GlobalNine Indonesia, Niaga Kalimas Blok-A No.5 Bekasi Timur, BekasiPhone: +62 21 8835 7506 / Fax +62 21 8835 7507, Web: www.global9-ind.com

PRESENTED BY:

NetMACS II TM

Page 2: PT. GlobalNine Indonesia, Niaga Kalimas Blok-A No.5 Bekasi Timur, Bekasi Phone: +62 21 8835 7506 / Fax +62 21 8835 7507, Web:  PRESENTED.
Page 3: PT. GlobalNine Indonesia, Niaga Kalimas Blok-A No.5 Bekasi Timur, Bekasi Phone: +62 21 8835 7506 / Fax +62 21 8835 7507, Web:  PRESENTED.

The NetMACS II is a flexible and cost effective solution to monitoring locations ranging from confined area such as cabinet to large and diverse environments such as central offices.

The NetMACS II can be programmed to perform local control and evaluation such as threshold based alarming and trending.

It can also be used to program complex algorithm-based decision making. Data can be accessed graphically via a standard web browser over a network. Using this web interface, commands and changes to setpoint can be input through pushbuttons and slide bars

• 24 – 768 Inputs

Automatic range selection monitors inputs from 60VDC to battery float current levels via a 50mV shunt.

• Isolated Outputs

Four isolated relay drivers and two isolated analog output.

• 0.5% Accuracy of Analog Data

• 1U Rack Height

19” or 23” rack or wall mountable

• Modem/Network Compatible

• Web Based

Communication capability including e-Mail alert messaging.

The NetMACS II is capable of monitoring all plant voltages and signals. It can produce a status report for these voltages and signals in over specified of the plant operation. This gives the user the capability to track a plant performance over a long period of time.

A basic NetMACS has 24 universal inputs, 4 isolated relay drivers and 2 isolated analog outputs. This input will automatically switch from a 60VDC range to a 50mV range (accuracy of 0.5%, with a resolution of 20 microvolts in the 50mV range). This basic functionality can be expanded by adding suplemental monitoring units, up to a total of 768 inputs.

NetMACSTM

IIControl and Monitoring System

Monitoring

Product Description

Page 4: PT. GlobalNine Indonesia, Niaga Kalimas Blok-A No.5 Bekasi Timur, Bekasi Phone: +62 21 8835 7506 / Fax +62 21 8835 7507, Web:  PRESENTED.

The NetMACS II operating system allows the programmer to create functional control programs. These programs can be site specific and based upon the values of any or all Analog Inputs, Analog Outputs, Timers, Digital Input Registers, Function and status of any or All Digital Input, Digital Outputs, Date, Time of Day, etc. These program can be started either automatically, manually with a switch or remotely with a macro.

Programming

The NetMACS II has wide array of communication capabilities. These include:

• Ethernet 10 base-T running TCP/IP * Http Web enabled * SNMP upgradeable

Communications

Typical Programs

Power Plant Controls

• Automatic Equalizing * Battery Thermal Protection

• Load Shedding * Time Schedulling

• Spare Rotation * Runtime Logging

• Trend Logs * Automatic Status Reporting

• Monthly Report

Environmental Controls

• Fixed Time Duty Cycling * Night Purge

• Lead/Lag Control * Seasonal Change-over

• Duty Cycling * Optimum Start/Stop

• Staging Control * Security System Control

• AC Generator Test

The NetMACS II units, when parameter are established, can control the plants performance characteristics.

Controls

Page 5: PT. GlobalNine Indonesia, Niaga Kalimas Blok-A No.5 Bekasi Timur, Bekasi Phone: +62 21 8835 7506 / Fax +62 21 8835 7507, Web:  PRESENTED.
Page 6: PT. GlobalNine Indonesia, Niaga Kalimas Blok-A No.5 Bekasi Timur, Bekasi Phone: +62 21 8835 7506 / Fax +62 21 8835 7507, Web:  PRESENTED.

Software

NetMACS IIControl & Monitoring System

Basic Module with Max. 31 Supl. Module

DC Power Plant

Plumbing System

Fire Alarm System

Security System

AC Plant

Manual Control

Lighting System

Email Email Alert

Visual Alert

Audible Alarm

Functional Programs

Spare RotationLoad SheddingAuto EqualizingRemote ON/OFFRemote Equalizing

•Periodic Report•Trend Logging•Event Logging

Network

Control&Monitoring

Typical Configuration SMS SMS Alert

Power System

Security System

Fire Alarm System,ETC

SMS

SMS Control

Call Phone Call

Page 7: PT. GlobalNine Indonesia, Niaga Kalimas Blok-A No.5 Bekasi Timur, Bekasi Phone: +62 21 8835 7506 / Fax +62 21 8835 7507, Web:  PRESENTED.

Lighting System

Plumbing System

Single Site Configuration

(Example)

NetMACS IIControl & Monitoring System

Basic Module(24 Input, 6HW Output)

2X Suplementary Module(48 Input, 12 HW Output)

2X Suplementary Module(48 Input, 12 HW Output)

Security System

3X Suplementary Module(72 Input, 18 HW Output)

Fire Alarm System

3X Suplementary Module(72 Input, 18 HW Output)

Vacant

15X Suplementary Module(360 Input, 90 HW Output)

Antena System

2X Suplementary Module(48 Input, 12 HW Output)

AC Power System

2X Suplementary Module(48 Input, 12 HW Output)

DC Power System

2X Suplementary Module(48 Input, 12 HW Output)

Regional

World Wide

Network

Local

Direct Connection

Page 8: PT. GlobalNine Indonesia, Niaga Kalimas Blok-A No.5 Bekasi Timur, Bekasi Phone: +62 21 8835 7506 / Fax +62 21 8835 7507, Web:  PRESENTED.

Monitoring Display

(Single Site)

Page 9: PT. GlobalNine Indonesia, Niaga Kalimas Blok-A No.5 Bekasi Timur, Bekasi Phone: +62 21 8835 7506 / Fax +62 21 8835 7507, Web:  PRESENTED.

Monitoring Display (Cont’d)

(Single Site)

Page 10: PT. GlobalNine Indonesia, Niaga Kalimas Blok-A No.5 Bekasi Timur, Bekasi Phone: +62 21 8835 7506 / Fax +62 21 8835 7507, Web:  PRESENTED.

Control & Monitoring Display

(Single Site)

TYPE : PECO II 3874B

NOM CAPACITY : 200

LOAD : 87.5AMPAMP

VOLTAGE : 53.50 VOLTTEMP : 35.8 DEG CRFA STAT : OFF

TYPE : PECO II 3874B

NOM CAPACITY : 200

LOAD : 87.5AMPAMP

VOLTAGE : 53.50 VOLTTEMP : 35.8 DEG CRFA STAT : OFF

TYPE : PECO II 3874B

NOM CAPACITY : 200

LOAD : 87.5AMPAMP

VOLTAGE : 53.50 VOLTTEMP : 35.8 DEG CRFA STAT : OFF

TYPE : PECO II 3874B

NOM CAPACITY : 200

LOAD : 87.5AMPAMP

VOLTAGE : 53.50 VOLTTEMP : 35.8 DEG CRFA STAT : OFF

ON ON

ON ON

Page 11: PT. GlobalNine Indonesia, Niaga Kalimas Blok-A No.5 Bekasi Timur, Bekasi Phone: +62 21 8835 7506 / Fax +62 21 8835 7507, Web:  PRESENTED.
Page 12: PT. GlobalNine Indonesia, Niaga Kalimas Blok-A No.5 Bekasi Timur, Bekasi Phone: +62 21 8835 7506 / Fax +62 21 8835 7507, Web:  PRESENTED.

NetMACS IIControl & Monitoring System

Basic Module with Max. 31 Supl. Module

Network

Site No.1

Software

Typical Configuration

Power System

Security System

Fire Alarm System,etc

(Multi Site)NetMACS II

Control & Monitoring System

Basic Module with Max. 31 Supl. Module

Site No.2

Site No.3

Site No.4

Site No.5

Site No.XX

Database

NetMACS IIControl & Monitoring System

Basic Module with Max. 31 Supl. Module

NetMACS IIControl & Monitoring System

Basic Module with Max. 31 Supl. Module

NetMACS IIControl & Monitoring System

Basic Module with Max. 31 Supl. Module

NetMACS IIControl & Monitoring System

Basic Module with Max. 31 Supl. Module

Site No.5

Master Control Centre

Mobile C&M Mobile C&M

Page 13: PT. GlobalNine Indonesia, Niaga Kalimas Blok-A No.5 Bekasi Timur, Bekasi Phone: +62 21 8835 7506 / Fax +62 21 8835 7507, Web:  PRESENTED.

Control & Monitoring Display

(Multi Site)

Site #1: SGI-DM

Normal

Minor

Major

Ctritical

Site #2: SGI-Ancol

Normal

Minor

Major

Ctritical

Site #3: SGI-MDN

Normal

Minor

Major

Ctritical

Site #4: SGI-SBY

Normal

Minor

Major

Ctritical

Site #5: SGI-BLI

Normal

Minor

Major

Ctritical

Site #6: BTS-CBR

Normal

Minor

Major

Ctritical

Site #7: BTS-CKG

Normal

Minor

Major

Ctritical

Site #9: BTS-MKS

Normal

Minor

Major

Ctritical

Site #10: LOC-MND

Normal

Minor

Major

Ctritical

Site #11: LOC-SMD

Normal

Minor

Major

Ctritical

Site #12: LOC-BJD

Normal

Minor

Major

Ctritical

Site #13: LOC-PTK

Normal

Minor

Major

Ctritical

Site #14: LOC-MTR

Normal

Minor

Major

Ctritical

Site #15: LOC-KPG

Normal

Minor

Major

Ctritical

Site #17: BTS-BDG

Normal

Minor

Major

Ctritical

Site #18: BTS-CMH

Normal

Minor

Major

Ctritical

Site #19: BTS-SKB

Normal

Minor

Major

Ctritical

Site #20: BTS-CRB

Normal

Minor

Major

Ctritical

Site #21: BTS-PWT

Normal

Minor

Major

Ctritical

Site #22: BTS-JGK

Normal

Minor

Major

Ctritical

Site #23: BTS-MLG

Normal

Minor

Major

Ctritical

Site #8: BTS-BGR

Normal

Minor

Major

Ctritical

Site #16: BTS-CBT

Normal

Minor

Major

Ctritical

Site #24:BTS-SMG

Normal

Minor

Major

Ctritical