The NetMACS II is a flexible and cost effective solution to monitoring locations ranging from confined area such as cabinet to large and diverse environments such as central offices.
The NetMACS II can be programmed to perform local control and evaluation such as threshold based alarming and trending.
It can also be used to program complex algorithm-based decision making. Data can be accessed graphically via a standard web browser over a network. Using this web interface, commands and changes to setpoint can be input through pushbuttons and slide bars
• 24 – 768 Inputs
Automatic range selection monitors inputs from 60VDC to battery float current levels via a 50mV shunt.
• Isolated Outputs
Four isolated relay drivers and two isolated analog output.
• 0.5% Accuracy of Analog Data
• 1U Rack Height
19” or 23” rack or wall mountable
• Modem/Network Compatible
• Web Based
Communication capability including e-Mail alert messaging.
The NetMACS II is capable of monitoring all plant voltages and signals. It can produce a status report for these voltages and signals in over specified of the plant operation. This gives the user the capability to track a plant performance over a long period of time.
A basic NetMACS has 24 universal inputs, 4 isolated relay drivers and 2 isolated analog outputs. This input will automatically switch from a 60VDC range to a 50mV range (accuracy of 0.5%, with a resolution of 20 microvolts in the 50mV range). This basic functionality can be expanded by adding suplemental monitoring units, up to a total of 768 inputs.
NetMACSTM
IIControl and Monitoring System
Monitoring
Product Description
The NetMACS II operating system allows the programmer to create functional control programs. These programs can be site specific and based upon the values of any or all Analog Inputs, Analog Outputs, Timers, Digital Input Registers, Function and status of any or All Digital Input, Digital Outputs, Date, Time of Day, etc. These program can be started either automatically, manually with a switch or remotely with a macro.
Programming
The NetMACS II has wide array of communication capabilities. These include:
• Ethernet 10 base-T running TCP/IP * Http Web enabled * SNMP upgradeable
Communications
Typical Programs
Power Plant Controls
• Automatic Equalizing * Battery Thermal Protection
• Load Shedding * Time Schedulling
• Spare Rotation * Runtime Logging
• Trend Logs * Automatic Status Reporting
• Monthly Report
Environmental Controls
• Fixed Time Duty Cycling * Night Purge
• Lead/Lag Control * Seasonal Change-over
• Duty Cycling * Optimum Start/Stop
• Staging Control * Security System Control
• AC Generator Test
The NetMACS II units, when parameter are established, can control the plants performance characteristics.
Controls
Software
NetMACS IIControl & Monitoring System
Basic Module with Max. 31 Supl. Module
DC Power Plant
Plumbing System
Fire Alarm System
Security System
AC Plant
Manual Control
Lighting System
Email Email Alert
Visual Alert
Audible Alarm
Functional Programs
Spare RotationLoad SheddingAuto EqualizingRemote ON/OFFRemote Equalizing
•Periodic Report•Trend Logging•Event Logging
Network
Control&Monitoring
Typical Configuration SMS SMS Alert
Power System
Security System
Fire Alarm System,ETC
SMS
SMS Control
Call Phone Call
Lighting System
Plumbing System
Single Site Configuration
(Example)
NetMACS IIControl & Monitoring System
Basic Module(24 Input, 6HW Output)
2X Suplementary Module(48 Input, 12 HW Output)
2X Suplementary Module(48 Input, 12 HW Output)
Security System
3X Suplementary Module(72 Input, 18 HW Output)
Fire Alarm System
3X Suplementary Module(72 Input, 18 HW Output)
Vacant
15X Suplementary Module(360 Input, 90 HW Output)
Antena System
2X Suplementary Module(48 Input, 12 HW Output)
AC Power System
2X Suplementary Module(48 Input, 12 HW Output)
DC Power System
2X Suplementary Module(48 Input, 12 HW Output)
Regional
World Wide
Network
Local
Direct Connection
Monitoring Display
(Single Site)
Monitoring Display (Cont’d)
(Single Site)
Control & Monitoring Display
(Single Site)
TYPE : PECO II 3874B
NOM CAPACITY : 200
LOAD : 87.5AMPAMP
VOLTAGE : 53.50 VOLTTEMP : 35.8 DEG CRFA STAT : OFF
TYPE : PECO II 3874B
NOM CAPACITY : 200
LOAD : 87.5AMPAMP
VOLTAGE : 53.50 VOLTTEMP : 35.8 DEG CRFA STAT : OFF
TYPE : PECO II 3874B
NOM CAPACITY : 200
LOAD : 87.5AMPAMP
VOLTAGE : 53.50 VOLTTEMP : 35.8 DEG CRFA STAT : OFF
TYPE : PECO II 3874B
NOM CAPACITY : 200
LOAD : 87.5AMPAMP
VOLTAGE : 53.50 VOLTTEMP : 35.8 DEG CRFA STAT : OFF
ON ON
ON ON
NetMACS IIControl & Monitoring System
Basic Module with Max. 31 Supl. Module
Network
Site No.1
Software
Typical Configuration
Power System
Security System
Fire Alarm System,etc
(Multi Site)NetMACS II
Control & Monitoring System
Basic Module with Max. 31 Supl. Module
Site No.2
Site No.3
Site No.4
Site No.5
Site No.XX
Database
NetMACS IIControl & Monitoring System
Basic Module with Max. 31 Supl. Module
NetMACS IIControl & Monitoring System
Basic Module with Max. 31 Supl. Module
NetMACS IIControl & Monitoring System
Basic Module with Max. 31 Supl. Module
NetMACS IIControl & Monitoring System
Basic Module with Max. 31 Supl. Module
Site No.5
Master Control Centre
Mobile C&M Mobile C&M
Control & Monitoring Display
(Multi Site)
Site #1: SGI-DM
Normal
Minor
Major
Ctritical
Site #2: SGI-Ancol
Normal
Minor
Major
Ctritical
Site #3: SGI-MDN
Normal
Minor
Major
Ctritical
Site #4: SGI-SBY
Normal
Minor
Major
Ctritical
Site #5: SGI-BLI
Normal
Minor
Major
Ctritical
Site #6: BTS-CBR
Normal
Minor
Major
Ctritical
Site #7: BTS-CKG
Normal
Minor
Major
Ctritical
Site #9: BTS-MKS
Normal
Minor
Major
Ctritical
Site #10: LOC-MND
Normal
Minor
Major
Ctritical
Site #11: LOC-SMD
Normal
Minor
Major
Ctritical
Site #12: LOC-BJD
Normal
Minor
Major
Ctritical
Site #13: LOC-PTK
Normal
Minor
Major
Ctritical
Site #14: LOC-MTR
Normal
Minor
Major
Ctritical
Site #15: LOC-KPG
Normal
Minor
Major
Ctritical
Site #17: BTS-BDG
Normal
Minor
Major
Ctritical
Site #18: BTS-CMH
Normal
Minor
Major
Ctritical
Site #19: BTS-SKB
Normal
Minor
Major
Ctritical
Site #20: BTS-CRB
Normal
Minor
Major
Ctritical
Site #21: BTS-PWT
Normal
Minor
Major
Ctritical
Site #22: BTS-JGK
Normal
Minor
Major
Ctritical
Site #23: BTS-MLG
Normal
Minor
Major
Ctritical
Site #8: BTS-BGR
Normal
Minor
Major
Ctritical
Site #16: BTS-CBT
Normal
Minor
Major
Ctritical
Site #24:BTS-SMG
Normal
Minor
Major
Ctritical