IE RE D i a . 11 0 m m p . v . c . s o i l p i p e w i t h m i n . 1 : 1 0 0 f a l l t o s e p t i c t a n k GULLY wc wc IE IE IE IE RE IE RE GULLY IE IE D/SSteel sink IE RE IE GULLY TRAP RE IE IE Dia. 110mm p.v.c. soil pipe with min.1:100 fall to septic tank Dia. 110mm p.v.c. soil pipe with min.1:100 fall to septic tank Vent pipe fitted with 2-way anti-vac vent valve 100 000 T.O.Uffl/ Surface bed NGL 105 970 Apex of highest roof 102 125 U.S.Conc. lintol. 100 000 T.O.Uffl/ Surface bed NGL 105 970 Apex of highest roof 102 125 U.S.Conc. lintol. 100 000 T.O.Uffl/ Surface bed NGL 105 970 Apex of highest roof 102 125 U.S.Conc. lintol. 100 000 T.O.Uffl/ Surface bed NGL 105 970 Apex of highest roof 102 125 U.S.Conc. lintol. 104 340 Apex of toilet roof Apex of toilet roof 100 000 T.O.Uffl/ Surface bed NGL NGL 104 960 U.S.Window lintol. 105 970 Apex of highest roof 100 000 T.O.Uffl/ Surface bed 101 900 U.S.Conc. lintol. 104 960 U.S.Window lintol. 105 970 Apex of highest roof 102 125 U.S.Window lintol. 102 125 U.S.Window lintol. 100 000 T.O.Uffl/ Surface bed NGL NGL 104 960 U.S.Conc. lintol. 105 970 Apex of highest roof 100 000 T.O.Uffl/ Surface bed 104 960 U.S.Conc. lintol. 105 970 Apex of highest roof 102 125 U.S.Window lintol. 102 125 U.S.Window lintol. 104 340 Apex of toilet roof Apex of toilet roof 100 000 T.O.Uffl/ Surface bed NGL NGL 100 000 T.O.Uffl/ Surface bed 106 040 Apex of highest roof 102 125 U.S.Conc. lintol. 102 125 U.S.Conc. lintol. 102 380 U.S.of Ceiling 102 380 U.S.of Ceiling 103 145 U.S Timber Beam 103 145 U.S Timber Beam 100 680 T.O.Rock Col. 100 680 T.O.Rock Col. NGL 100 000 T.O.Uffl/ Surface bed 102 125 U.S.Conc. lintol. 102 380 U.S.of Ceiling 103 380 Apex of toilet roof 100 680 T.O.Rock Cladding 106 040 Apex of highest roof NGL 100 000 T.O.Uffl/ Surface bed 101 900 U.S.Conc. lintol. 102 380 U.S.of Ceiling dpc dpc dpc dpc dpc dpc 16440 3375 1215 300 11250 300 230 2915 230 460 5270 460 4600 460 1650 3620 1800 115 1000 16440 3375 1515 6190 5060 300 230 2915 230 460 5270 460 4600 460 450 5290 450 1800 115 1000 15300 2300 3570 4290 3240 1150 450 300 450 1850 460 3110 230 1800 230 1800 230 2780 460 1150 15300 2300 11100 1600 300 450 1850 460 3420 460 2980 460 2860 460 1150 450 230 1100 230 110 460 110 460 110 3200 110 3400 110 110 2080 110 920 110 Proffice Building, 23 Corridor Crescent, Route N4 Business Park, Ben Fleur Ext 11 Post: P.O. Box 543, Emalahleni, 1035 Tel: 013-653 6321 / 653 6305 Fax: 086 567 5564 Email: [email protected] PRINCIPAL AGENT SIGNATURE: DEPARTMENT'S SIGNATURE: ARCHITECTS SIGNATURE: No: Date: Notes: Drawn: COPYRIGHT RESERVED COPYRIGHT NOTICE COPYRIGHT @ 2017- Bakopane Architects cc Copyright subsists in this drawing. The person or entity whose name appears in the tile block of this drawing, is hereby granted a non-exclusive licence to use, display, print and/ or reproduce this drawing to the extend necessary to carry out and complete the project described in the title block of this drawing. This licence in respect of the copyright is expressly limited as aforesaid and the person and / or entity referred to above shall not be entitled to grant sub-licences in respect of the copyright in this drawing to any other entity. This licence confers no ownership rights in the copyright vesting in the drawing and this drawing and the copyright subsisting therein will, at all times, remain the property of Bakopane Architects cc. Any unauthorised reproduction, publication, transmission, adaption and/or inclusion of this drawing in a cinematograph film or television broadcast is an act of copyright infringement which will render the doer of the act liable for civil law copyright infringement and may in certain circumstances render the doer liable to criminal prosecution. Requests and enquiries concerning this drawing and the rights subsisting therein should be addressed to the copyright owner. DRG. SIZE ORIGINAL REV. 01 A1 GENERAL NOTES: 1. Check all measurements,levels and details on site before commencement with work. 2. Refer any discreptancies to architect 3. All work to be done in accordance with SANS-10400 4. Nothing to be scaled from drawing: request measurement from architect 5. Architect's & engineer's drawings to be read together 6. Drawing to be used for intention as mentioned in Drawing description. TITLE: PROPOSED ALTERATIONS & ADDITIONS TO TAUNG SKULL HERITAGE SITE FOR NORTH-WEST RURAL, ENVIRONMENTAL & AGRICULTURE DEPARTMENT PROVINCE OF NORTH-WEST DRG No.: TAUNG - 42017 - ARC - SC01 SCALE: 1/100/20 CLIENTS SIGNATURE: DRAWING DESCRIPTION: Stone Cottage Floor plans, Elevations, Sections & Typical Detail. CEILING: Everite Nutec 6mm thick plain ceiling boards SANS 9001:2000 carrying SANS 803:2005 mark, fixed smooth face down with joints finished with Bishoff strips. Boards to be nailed to 38x114mm beam & 38x38mm SA Pine brandering (structural grade) @ max 400mm c/c in one direction. Apply one coat universal primer to all exposed nail heads before applying two coats final paint color to ceiling boards. Color to be verified by architect. All to manufacturers specs & details. 1 2 1 2 1 1 1 2 1 Kitchen patio Entrance patio 1 2 1 Entrance patio Entrance patio Kitchen patio 1 2 Kitchen patio Kitchen Reception Waiting area Entr. patio Gents Toil Kitchen Boardroom Lobby Rock walls Rock walls Rock walls Rock walls Rock walls Rock walls Rock cladding Rock cladding Rock cladding Rock walls Rock walls Void above ceiling Steel edge trim. Walk-through to Reception & waiting area WHB WC STOVE WORK-TOP ,VAAL' PEARL PARAPLEGIC SEMI CLOSE COUPLE SUITE PRODUCT CODE 7300SC. Vaal Sanitaryware vitreous china "Pearl Paraplegic" semi-close coupled 90° outlet open rim washdown pan and matching 9 litre cistern complete with lid, fitments, & purpose made C.P. side-flush lever (left or right). Supplied with purpose made thermoset seat and cover plate. 02 02 As per supplier 'VAAL' HIBISCUS BASIN PRODUCT CODE 702303 DESCRIPTION. Vaal Sanitaryware vitreous china 510 x 405mm rounded “Hibiscus” basin with three semi-punched tapholes (i.e. available in zero, one, two or three taphole configurations), integrated overflow, and chainstay hole through the centre semi-punched taphole. To be finished in white as per supplier. 'VAAL Accessories" (code 71511086) 205x160x90mm. Install accessories against brick or tiled wall with super-glue and seal with silicone sealant. 02 02 02 As per supplier 32mm stainless steel grab rail by specialists. As per supplier specifications. Varies 01 - WC No. Req. Specification 02 - WHB 03 - WHB TRAP & PLUG 04 - VALVE SYSTEM 06 - TOILET ROLL HOLDER PARAPLEGIC TOILET 05 - GRAB RAILS Scale 1:100 North Elevation Scale 1:100 South Elevation Scale 1:100 West Elevation Scale 1:100 East Elevation Scale 1:50 Section A - A Scale 1:50 Section B - B Scale 1:20 Typical Elev. Scale 1:20 Sect. C - C Scale: NTS Sanitary schedule New Purpose Made Oregon Pine vertical sliding sash, double glazed window, plugged & screwed into existing brick wall by Oregon pine specialist. Old World Concretes Type 6 window sill, size 340 x 85 x 1100mm long bed, bedded and jointed in Class II mortar and pointed on all exposed faces. Exisiting Rock walls Exisiting Rock wall Gundle® API A.T USB Green 3 layer 250μm damp proof course laid in wall joints, conforming to (SANS 952-1:2011 Type C) laid with minimum 150mm overlaps and sealed with Gunplas pressure sensitive tape. INSIDE COTTAGE AREA SCHEDULE: Area of existing cottage: 124.87 sq.m Area of main entr. patio : 19.63 sq.m Area of existing kitchen patio: 14.23 sq.m Total Area of existing cottage: 158.73 sq.m Area of additional ablutions: 18.25 sq.m Total combined Area of cottage: 176.98 double glazing double glazing double glazing double glazing Stove Ssteel d/sink Kitchen Frdg 1 2 1 2 Board rm. Waiting Area Reception Office 1 Office 2 Entrance patio Kitchen patio Floor mounted chairs 2.1m Overhead Floor mounted chairs Ladies Toil. Gents Toil. Whb Whb Wc Wc Passage Kitchen patio Lobby 1m Paving apron 1m Paving apron 1m Paving apron 1m Paving apron 1m Paving apron 1m Paving apron 1m Paving apron porcelain tiles finish porcelain tiles finish porcelain tiles finish porcelain tiles finish porcelain tiles finish porcelain tiles finish porcelain tiles finish porcelain tiles finish porcelain tiles finish porcelain tiles finish Plaster & paint Plaster & paint Plaster & paint NEW ROOF NOTE: 'Hulamin' 0,80mm thick Corrugated s-profile or similar SABS approved Hazy Grey pre-coated finish aluminium roof sheeting, fixed to timber intermediate purlins at 670mm centres and eaves and ridge purlins at 640mm centres using fastening system approved by manufacturer and fixed in accordance with the manufacturer`s recommendations. Overhangs to be 600mm maximum. NEW ROOF NOTE: 'Hulamin' 0,80mm thick Corrugated s-profile or similar SABS approved Hazy Grey pre-coated finish aluminium roof sheeting, fixed to timber intermediate purlins at 670mm centres and eaves and ridge purlins at 640mm centres using fastening system approved by manufacturer and fixed in accordance with the manufacturer`s recommendations. Overhangs to be 600mm maximum. NEW ROOF NOTE: 'Hulamin' 0,80mm thick Corrugated s-profile or similar SABS approved Hazy Grey pre-coated finish aluminium roof sheeting, fixed to timber intermediate purlins at 670mm centres and eaves and ridge purlins at 640mm centres using fastening system approved by manufacturer and fixed in accordance with the manufacturer`s recommendations. Overhangs to be 600mm maximum. NEW ROOF NOTE: 'Hulamin' 0,80mm thick Corrugated s-profile or similar SABS approved Hazy Grey pre-coated finish aluminium roof sheeting, fixed to timber intermediate purlins at 670mm centres and eaves and ridge purlins at 640mm centres using fastening system approved by manufacturer and fixed in accordance with the manufacturer`s recommendations. Overhangs to be 600mm maximum. Ridge cap as supplied by "Hulamin" Sisalation: Sheeting & purlins to have fixed Laminated aluminium, Sisalation®410 Reflective Foil Insulation with reinforced with fiberglass & flame retardant additives as per Manufacturers specifications. Lay 135mm Aerolite insulation (Non-combustible andClass 1 fire index rating) on the ceiling ensuring that it fits tightly between the tie beams. Aerolite should be cut 50mm more than distance between the tie beams. Cut Aerolite out around trap doors. Fix the cut section to the back of the trap door using a good quality contact adhesive. Wrap Aerolite around cold and hot water pipes ensuring that there is 10mm overlap. Secure the Aerolite using a cable tie at 300mm centres. K-value: 0.040 W/mK (ASTM C518) Everite Nutec 6mm thick plain ceiling boards, manufactured in accordance with SANS 9001:2000 carrying SANS 803:2005 mark, fixed smooth face down, to 38mm x 50mm hardwood battens at 600mm centres using 32 x 2,5mm serrated ceiling nails at 150mm centres, minimum of 12mm from edge of boards. Apply one coat universal primer to all exposed nail heads before applying two coats final paint color to ceiling boards. Color as per architect. Finish off with NUTEC 19mm Wood cleat all round, where ceiling meets wall surfaces. New 25mm Screed of 30MPa strength, on existing concrete slab to fall at 1:100 away from the structure. Screed mixed at 4:1:1 ratio crusher sand: plaster sand: cement and finished smooth with a steel trowel. All concrete work to be inspected and approved by engineers. 85mm reinforced concrete surfacebed, of min. strength 30MPa to Engineers Dets & specs. 85mm reinforced concrete surfacebed, of min. strength 30MPa to Engineers Dets & specs. Gundle® API A.T USB Green 3 layer 250μm damp proof course laid in wall joints, conforming to (SANS 952-1:2011 Type C) laid with minimum 150mm overlaps and sealed with Gunplas pressure sensitive tape. 85mm reinforced concrete surfacebed, of min. strength 30MPa to Engineers Dets & specs. 85mm reinforced concrete surfacebed, of min. strength 30MPa to Engineers Dets & specs. Existing footing Existing footing Existing footing Existing footing Existing footing Existing footing New 114x38mm THK SA Pine treated beams New 114x38mm THK SA Pine treated beams Everite Nutec 6mm thick plain ceiling boards, manufactured in accordance with SANS 9001:2000 carrying SANS 803:2005 mark, fixed smooth face down, to 38mm x 50mm hardwood battens at 600mm centres using 32 x 2,5mm serrated ceiling nails at 150mm centres, minimum of 12mm from edge of boards. Apply one coat universal primer to all exposed nail heads before applying two coats final paint color to ceiling boards. Color as per architect. Finish off with NUTEC 19mm Wood cleat all round, where ceiling meets wall surfaces. NEW ROOF NOTE: 'Hulamin' 0,80mm thick Corrugated s-profile or similar SABS approved Hazy Grey pre-coated finish aluminium roof sheeting, fixed to timber intermediate purlins at 670mm centres and eaves and ridge purlins at 640mm centres using fastening system approved by manufacturer and fixed in accordance with the manufacturer`s recommendations. Overhangs to be 600mm maximum. NEW ROOF NOTE: 'Hulamin' 0,80mm thick Corrugated s-profile or similar SABS approved Hazy Grey pre-coated finish aluminium roof sheeting, fixed to timber intermediate purlins at 670mm centres and eaves and ridge purlins at 640mm centres using fastening system approved by manufacturer and fixed in accordance with the manufacturer`s recommendations. Overhangs to be 600mm maximum. Lay 135mm Aerolite insulation (Non-combustible andClass 1 fire index rating) on the ceiling ensuring that it fits tightly between the tie beams. Aerolite should be cut 50mm more than distance between the tie beams. Cut Aerolite out around trap doors. Fix the cut section to the back of the trap door using a good quality contact adhesive. Wrap Aerolite around cold and hot water pipes ensuring that there is 10mm overlap. Secure the Aerolite using a cable tie at 300mm centres. K-value: 0.040 W/mK (ASTM C518) d1 d2 d2 d3 d3 d3 d4 d5 d5 w1 w1 w1 w1 w3 w3 w2 w2 w2 w2 w3 w2 w3 w2 w1 w1 w1 w1 d1 d2 d2 w2 w2 d1 d2 d3 d3 d3 w2 w2 w3 d5 B B A A Scale 1:100 Ground level floor plan