HOTEL LOUISIANA

Dinesha , German, Victor, Suganeya HOTEL LOUISIANA

Design ProcedureLoadsRisaSlabBeamsStrirrupColumnsDeflection and drift

Buildings Front Frame

Building overview

Buildings Side Frame

Building overview

Design AssumptionsFs = 2/3fyAll the floors behave the sameAnalyzed only B1, B2, B3, G2, G3, G5, and G6Wind load was assumed to be only in one directionColumns came to different size than assumed.

Load Calculations

Load Calculations

Design loads on Risa software

Calculations done by RISA Software

Slab Calculations

Our different calculations for slab were for:Top floor (Roof)Mid floorsThe following figure are the moment coefficients for service moment calculations for the slabs.

Slab Design

Beams and Stirrup

Moment Diagram

Reinforcement Bars Equations used 1.2D + 1.6L1.2D + 1W + 1L + 0.5S0.9D + 1W1.4D

Beams/GirdersSelected Moment (k.ft)ROOF5TH FLOORGROUND FLOORB-1225377428B-3374505583G-1291382385G-2261378376G-5498658568G-6429561560B-2562604604

Reinforcement Bars #8 and #10 bars are used in our design

Beams/GirdersSelected BarsROOF5TH FLOORGROUND FLOORB-15 #87 #88#8B-37 #86 #107 #10G-16 #87 #88 #8G-23 #107 #87 #8G-56 #108#107 #10G-69 #87 #107 #10B-27 #107#107 #10

Reinforcement Bars Depth of compression block < 7.5in

t > 0.005 = Tension controlled

Sactual < Smaximum = Minimized cracking

Shear forces

StirrupsBars used was either #3 or #4Spacing varied by beamShear forces obtained from RisaMath cad made it simple to find spacing

Stirrups spacing for HotelStirrups for G-5 and G-6MemberVu (kips)Vn requiredVn actualmax spacingSpacingStirrupstop floor51 (G5) 10th76101.333102.891110#4@10top floor52 (G6) 10th5978.66779.2951110#3@10mid floor71 (G5) 5th6282.66786.597118#3@8mid floor72 (G6) 5th6485.33386.597118#3@8bottom floor 91 (G5) 66.34188.45591.812117#3@7bottom floor 92 (G6)67.8590.46791.812117#3@7

Math Cad Calculation sample

An example of how stirrups were found.

Columns

Axial force

Moments

Columns Design

Drift and Deflections

Beam Deflection

We did not calculate deflection Because we meet ACI requirements for beams

If we plug our values in table 9.3.1.1 we are ok according to the code.

Maximum deflection limitation from ACI code : l/360 = 1.13 inch

Deflection of Hotel Louisiana = 0.36 inch

Drift

Same goes for drift, we found Maximum drift limitation from ACI code : h/400 = 3.795 inch

Max Drift of Hotel Louisiana = 1.1 inch

Maximum drift limitation from ACI code : h/400 = 3.795 inch

Max Drift of Hotel Louisiana = 1.1 inch

ConclussionHotel Louisiana meets ACI requirements.

Could have gone more cost effective design.

Thank you!