Program Number AA3010 Presented By: Name Title Email Phone Door Opening Solutions for LEED for Healthcare Door Opening Solutions in LEED for Healthcare Program Number AA3010 USGBC Course Number 0090008707 Presented By: Aaron C. Smith, LEED AP BD+C Dir Sustainable Building Solutions [email protected]6123255719 = ASSA ABLOY is the global leader in door opening solutions, dedicated to satisfying end-user needs for security, safety and convenience
58
Embed
Program Number AA3010 Presented By: Name Title Email Phone Door Opening Solutions for LEED for Healthcare Door Opening Solutions in LEED for Healthcare.
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Program Number AA3010
Presented By:
Name
Title
Email
Phone
Door Opening Solutions for LEED for Healthcare
Door Opening Solutions in LEED for Healthcare Program Number AA3010
ASSA ABLOY is the global leader in door opening solutions, dedicated to satisfying end-user needs for security, safety and convenience
We want to know what our markets and customers want around Sustainability
At Perkins+Will, we're also helping to improve the environment through regenerative design.
Perkins+Will is also committed to exemplary workplace practices in our own business. Every one of our offices that is renovated or constructed is designed to LEED Platinum standards and metered to monitor performance. As a carbon-neutral organization, we're offsetting our carbon emissions and investing in renewable energy technologies.
We are committed to supporting a diverse culture of sustainable design through applied research, internal education, public advocacy and outreach. We have developed tools such as the Precautionary List and the 2030 Estimating + Evaluation Tool to advance our design expertise and have made them publicly-available to expand our industry's knowledge of sustainable design best practices. Through this research and development of innovative tools, we offer our clients a range ofsustainable advisory services.
ASSA ABLOY is committed to providing products and services that are environmentally sound throughout the entire production process and the product life-cycle.
Our unconditional aim is to make sustainability a central part of our business philosophy and culture, but even more importantly is the job of integrating sustainability into our business strategy.
Comprehensive Sustainability Report Issued since 2006 Utilizing Global Reporting Initiative Submitted to the United Nations
Learn more at www.assaabloydss.com/sustainability
ASSA ABLOY Door Security Solutions
ASSA ABLOY is the global leader in complete door opening solutions.
Our Team of Door Security Solutions Specialists are dedicated to providing efficient door solutions that balance the need for Aesthetics Convenience Life-safety Security Sustainability
Global Team of ExpertsAffiliations Door and Hardware Institute (DHI) American Institute of Architects (AIA) Construction Specifications Institute (CSI) International Interior Design Association (IIDA) American Society for Industrial Security (ASIS) United States Green Building Council (USGBC)
Integrated Design and BIM (all project phases) Code Compliance Review Try-Me Program product samples
Survey & Walkthrough of Existing Facilities Coordination with building systems & related trades Integrated, Sustainable & Aesthetic Design Solutions
Green your Division 8/28 Specifications Door & Hardware Schedules assistance Value Analysis, Sustainability Analysis
Review of Shop Drawings & Submittals Jobsite inspection & Punch lists Technical Support
Architectural Consulting by Project PhaseD
DC
DC
AS
D
AIA Continuing Education System
ASSA ABLOY Door Security Solutions is a Registered Provider with The American Institute of Architects. Credit earned on completion of this program will be reported to the CES Records for AIA members. Certificates of Completion for non-AIA members are available upon request
This program is registered with the AIA/CES for continuing professional education (HSW & SD). As such, it does not include content that may be deemed or construed to be an approval or endorsement by the AIA of any material of construction or any method or manner of handling, using, distributing, or dealing in any material or product. Questions related to specific materials, methods, and services will be addressed at the conclusion of this presentation
GBCI Continuing Education System
The U.S. Green Building Council (USGBC) has approved the technical and instructional quality of this course for 1 GBCI CE Hours towards the LEED Credential Maintenance Program
ASSA ABLOY is an USGBC Education Provider committed to enhancing the ongoing professional development of the building industry and LEED Professionals through high-quality education programs. As a USGBC Education Provider, ASSA ABLOY has agreed to abide by USGBC established operational and educational criteria, and is subject to annual reviews and audits for quality assurance
Copyright materials
This presentation is protected by US and International Copyright laws. Reproduction, distribution, display and use of the presentation without written permission of the speaker is prohibited
Please indicate on the Sign-in Sheet whether you would like an electronic copy of the presentation
Learning Objectives
At the conclusion of this program, participants will− Know the purpose and concepts behind LEED for Healthcare
− Describe how door opening solutions (DOS) can help building owners gain Energy & Atmosphere (EA) credits in LEED for Healthcare.
− Describe how DOS can help with Materials & Resources (MR) credits in LEED for Healthcare.
− Describe DOS can help building owners gain Indoor Environmental Quality (IEQ) credits in LEED for Healthcare.
What else would you like to learn?
LEED 2009 for Healthcare
The LEED for Healthcare rating system represents a culmination of seven years of close collaboration between the Green Guide for Healthcare (GGHC) and USGBC. GGHC has helped to streamline the LEED for Healthcare's development schedule by aligning with the LEED for New Construction rating system's organizational structure
The GGHC is the first voluntary, self-certifying toolkit of green building best practices customized for the healthcare sector
When to Use LEED 2009 for Healthcare
LEED for Healthcare was written primarily for inpatient and outpatient care facilities and licensed long term care facilities. The rating system may also be
used for medical offices, assisted living facilities and medical education and research centers
LEED for Healthcare addresses design and construction activities for both new buildings and major renovations of existing buildings
LEED for Healthcare Certification Levels
Green Building Certification Institute (GBCI) will recognize buildings that achieve one of these rating levels with a formal letter of certification.
40-49points
50-59points
60-79points
80+points
Sustainable Sites (SS)
Water Efficiency (WE)
Energy & Atmosphere (EA)
Materials & Resources (MR)
Indoor Environmental Quality (IEQ)
Innovation in Design
Regional Priority Credits
LEED for Healthcare Credit CategoriesHigh Performance Doors & Hardware
FO
CU
S
Energy & Atmosphere Categories impacted by Door Opening Solutions EAp2 Minimum Energy Performance
EAc1 Optimize Energy Performance 1-24 points
EAc3 Enhanced Commissioning 1-2 points
Door shows excessive thermal transfer
BEFORE
Door exterior shows no heat transfer
AFTER
Door Openings in the Building Envelope
Approx 40% of all air infiltration comes from the building envelope* Floors, Walls and
Ceilings – 31%
Windows – 10% Doors – 11%
*Tony Woods, Air tight buildings, 2005
**2005 Richard S. Duncan, PhD, PE, The Role of Air Sealing
**
EA Prerequisite 2 – Minimum Energy Performance Option 1 – Whole Building
Energy Simulation Demonstrate a 10%
improvement for new buildings, or a 5% improvement for major renovations to existing buildings.
Calculate improvement using the baseline building performance rating using ASHRAE Standard 90.1-2007
EA Credit 1 – Optimize Energy Performance
Demonstrate a percentage improvement in the proposed building performance rating compared with ASHRAE 90.1-2007
Operable U Value using ASTM C1363
Operable Air Leakage using ASTM E283
EA Credit 3 – Enhanced Commissioning
OPTION 1 (1 Point)
Designate an independent commissioning authority(CxA)
OPTION 2 (2 Points)
Achieve Option 1 AND commission the building’s thermal envelope systems
The building thermal envelope entails all exterior wall assemblies separating a building’s conditioned spaces from outdoor ambient conditions, including: roof assemblies, vapor barriers, air barrier systems, flashings, cladding and siding, windows, curtain-wall assemblies, doors, etc.
P
Insulated Core Doors
Closing & Latching
Thermal Break and Kerf Frames
Thresholds/Door Bottoms/Gasketing
EAC
Door Opening Solution Assemblies
24
Traditional Access Control vs Sustainable Thinking
Many discreet components create a larger environmental impact Additional wiring, energy use, more
Integrating all of these functions into a single integrated lockset reduces the number of manufactured components required at each door
Integrated Wiegand
26
IP-Enabled Access Control
IP-Enabled WiFi locks leverage existing infrastructure to reduce environmental impact even further Completely eliminates any additional
electronic access control infrastructure
WiFi
27
IP-Enabled Access Control
Power over Ethernet locks leverage existing PoE infrastructure to reduce components AND minimize energy usage PoE locks use a maximum of 7W per activation at
each lock, 50% less than typical PoE installations PoE locks also use 85% less standby power than
traditional access control
Power over Ethernet
An Energy Efficient Building
Optimize energy performance: entire building
Create a sealed barrier: prevent air infiltration, heat transfer
Each security component should be carefully selected− Thermal Break frames and Kerf frames
− Insulated doors
− Door hardware, EAC systems, power supplies
− Gasketing
BIM: performance characteristics of door assemblies
Following this strategy, doorways can be used to create a more energy efficient building
Material & Resources Categories Impacted by Doors Opening Solutions MRc1.2 - Building Reuse –
Maintain Existing Interior Non-Structural Elements 1 pt
1 pt and up to a maximum of 4 will be awarded for each 10% of the total value of all building materials and products used in the project (based on cost) that meet the criteria below:
Salvaged, refurbished or reused materials. Recycled content. Regionally sourced/manufactured materials and products that
have been extracted, harvested or recovered, as well as manufactured within 500 miles of the project site.
Rapidly renewable materials. Wood certified, in accordance with the Forest Stewardship
Council’s (FSC) Principles and Criteria.
MR Credit 3 – (Continued)
AND Wall, ceiling and flooring systems and finishes, composite wood, agrifiber and fiberglass products, both exterior and interior adhesives, sealants, coatings, roofing, and waterproofing products must meet the relevant IEQ Credit 4: Low-Emitting Materials requirements to contribute toward the credit.
Important that doors meet this requirement
Example: Flush FSC Wood Doors
Recycled Content – Door Opening Solutions The recycled content fraction is the sum of all post-
consumer recycled content plus one-half of the pre-consumer content.
Hollow Metal30-60%
Wood Doors20-85%
Hardware50-68%
Regional Material
Regionally sourced/manufactured materials and products that have been extracted, harvested or recovered, as well as manufactured within 500 miles of the project site
Rapidly Renewable
Rapidly Renewable building materials and products are made from plants that are typically harvested within a 10-year or shorter cycle.
Certified Wood content value is determined by multiplying the certified wood content
fraction of the assembly (based on weight) by the cost of the assembly.
Note: Only virgin wood stock shall contribute towards the certified wood criteria. Certified wood shall not contribute to the rapidly renewable criteria.
All vendors, except those installing, that invoice FSC products must have a Chain of Custody (COC) number
Example: Stile and Rail Door, FSC Wood
Indoor Environmental Quality Categories impacted by Door Opening Solutions IEQp2 – Environmental Tobacco
Smoke Control (prerequisite) IEQc2 – Acoustic Environment IEQc3.2 – Construction Indoor
Air Quality Management Plan Before Occupancy
IEQc4 - Low-Emitting Materials IEQc5 – Indoor Chemical &
Pollutant Source Control IEQc8.1-.2 – Daylight & Views
IEQ Prerequisite 2 – Environmental Tobacco Smoke Control
For residential healthcare occupancies only where accommodation for resident smoking is programmatically mandated
All exterior doors in the residential units shall be gasketed to minimize leakage from outdoors.
Example: Custom Sketch Veneer Door with Perimeter Gasketing
IEQ Credit 2 – Acoustic Environment
Provide building occupants with an indoor healing environment free of intrusive or disruptive levels of sound.
Door Opening Solutions can assist with Option 1 (1 Point) - Sound Isolation
Design sound isolation to achieve speech privacy, acoustic comfort and minimal annoyance from noise producing sources.
Door Opening Solutions rated from STC 27 - 55
Example: STC 54 Door with Solid Core, Frame and Drop Seal
IEQ Credit 3.2 – Construction Indoor Air Quality Management Plan – Before Occupancy
To reduce indoor air quality (IAQ) problems resulting from construction or renovation to promote the comfort and well-being of construction workers and building occupants
OPTION 1. Flush Out
OPTION 2. Air Testing Conduct baseline IAQ testing after construction ends and prior to
occupancy using testing protocols consistent with the EPA Compendium of Methods for the Determination of Air Pollutants in Indoor Air and as additionally detailed in the LEED Reference Guide for Green Building Design and Construction, 2009 Edition Healthcare Supplement.
Project teams specifying all interior products meeting GREENGUARD Children & Schools testing will assist with IEQ 3.2 compliance.
IEQ Credit 4 – Low-Emitting Materials
Reduce the quantity of indoor air contaminants that are odorous, irritating and/or harmful to the comfort and well-being of installers and occupants.
One point (maximum four) can be achieved for each group of materials that comply with the requirements.
GROUP 1: Interior Adhesives and Sealants
GROUP 2: Wall and Ceiling Finishes
GROUP 3: Flooring
GROUP 4: Composite Wood, Agrifiber and Batt Insulation Products
GROUP 5: Exterior Applied Products
Group 1 – Interior Adhesives & Sealants
This credit only applies to materials applied within the weatherproofing system however, pre-finished doors and pre-installed glazing will allow LEED projects to avoid applying materials onsite.
Example: Integrated Door Opening Assembly
Group 2 – Wall & Ceiling Finishes
All gypsum board, acoustical ceiling systems and wall coverings (doors) installed in the building interior must meet the testing and product requirements of the California Department of Health Services Standard Practice for the Testing of Volatile Organic Emissions from Various Sources Using Small-Scale Environmental Chambers, including 2004 Addenda (CA 01350).
Recommend GREENGUARD Indoor Air Quality certification (or similar) for Door Opening Solutions
Group 4 – Composite Wood, Agrifiber Products
Composite wood and agrifiber products used on the interior of the building (i.e., inside the weatherproofing system) shall contain no added urea-formaldehyde (NAUF) resins.
Composite wood and agrifiber products are defined as particleboard, medium density fiberboard (MDF), plywood, wheat board, strawboard, panel substrates and door cores.
Specify wood doors containing NAUF
IEQ Credit 5 – Indoor Chemical & Pollutant Source Control Minimize building occupant exposure to
potentially hazardous particulates and chemical pollutants.
Where hazardous gases or chemicals may be present or used—garages, soiled utility areas, sterilization and disinfection areas, housekeeping/laundry areas and copying/printing rooms—
exhaust each space sufficiently to create negative pressure with respect to adjacent spaces with the doors to the room closed.
For each of these spaces, specify closers on all door openings to provide self-closing doors.
Example: Stile and Rail Door with Gasketing and EAC
IEQ Credit 8.1/.2 – Daylight & Views
Provide building occupants a connection to the outdoors through the introduction of daylight and views into the regularly occupied areas of the building.
Adding glazing, toplights and sidelights to door openings will assist healthcare projects in achieving this LEED credit.
Example: Split Leaf Thermal Fused Door with Privacy Sidelight
Special Healthcare Applications
48
Antimicrobial Technologies
Help hospital leadership implement, expand, or improve their JCAHO-required program to manage and reduce nosocomial infections.
State of the art active surfaces that work to inhibit microbial populations on environmental surfaces.
Element of a program to reduce surface contamination that contributes to hospital maintenance risks.
Improving hygiene without increasing operating costs.
Special Healthcare Applications
Medical Bearing Hinges Self-lubricating with high resistance to wear Uniquely designed to provide clean and quiet hinge operation
50
Special Healthcare Applications
Multi-Point Hold Open Closer with Swing-Free Arm Patient Room, Corridor, and Stairwell use Can be provided with or without smoke detector Door operates as if no closer installed In case of fire, door automatically closes from any position
Special Healthcare Applications
Door Closer with Motion Sensor Minimizes tactile contact from multiple occupants passing
through the opening Low Energy alternative to automatic operators
This Concludes the Educational Program
Thank you for attending!
What additional questions do you have about the program?
Please fill out the Form B AIA/CES HWS & SD, GBCI/CEU
Credits PDF of today’s presentation Request Certificate
Codes: National Fire Protection Association: www.nfpa.org International Code Council (ICC):
www.iccsafe.org ASHRAE
www.ashrae.org
Organizations: Construction Specifications Institute: www.csinet.org Window & Door Manufacturers Assoc: www.wdma.com Architectural Woodwork Institute: www.awinet.org Door and Hardware Institute: www.dhi.org United States Green Building Council: www.usgbc.org International Living Building Institute www.ilbi.org AIA 2030 Challenge: www.architecture2030.org