MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCES 9.955.056 02 Subject to change without notice Application Domestic gas appliances: room heaters and fireplaces. Main Features Automatic ignition gas control system that includes a user selectable intermit- tent or standing pilot Twin safety system with true flame detection for enhanced safety and reli- ability On/Off, manual High/Low, and remote modulation valve configurations Integrated for use with the Proflame Remote Control family GT, GTS, GTM, GTMS, GTMF, GTMFS Operable from a wall switch or a remote control Low power consumption design provides a choice of AC operation, battery opera- tion or AC power with battery backup. Normative reference ANSI Z21.78, ANSI Z21.20. Approvals CSA international. w w w . s i t c o n t r o l s . c o m PROFLAME
12

proflaMe - Sit Group

Dec 07, 2021

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: proflaMe - Sit Group

Multifunctional control for gas burning appliances

9.95

5.05

6 0

2

S

ubje

ct t

o ch

ange

with

out

notic

e

Application

Domestic gas appliances: room heaters and fireplaces. Main Features

Automatic ignition gas control system that includes a user selectable intermit-tent or standing pilot

Twin safety system with true flame detection for enhanced safety and reli-ability

On/Off, manual High/Low, and remote modulation valve configurations

Integrated for use with the Proflame Remote Control family GT, GTS, GTM, GTMS, GTMF, GTMFS

Operable from a wall switch or a remote control

Low power consumption design provides a choice of AC operation, battery opera-tion or AC power with battery backup.

Normative reference

ANSI Z21.78, ANSI Z21.20.

approvals

CSA international.

w w w . s i t c o n t r o l s . c o m

proflaMe

9955056_02(0�2)_��0-�-5_cat.indd1 1 2�/0�/2010 10.�5.��

Page 2: proflaMe - Sit Group

2

valve DeSCRIPTION

It consists of two automatic shut-off valves and a servo pressure regulator in series in the main gas path. With reference to the schematic block in Fig. 1:

• FLI is the inlet filter. • EV1 is the first automatic shut-off valve. • EV2 is the second automatic shut-off valve. • RP is a pressure regulator. • MD is a pressure modulator device.

• FLO is the outlet filter. • PA is the pilot adjustment screw. • FLP is the pilot filter.

GASINLET

FLI

EV1

RP

EV2

MAINBURNER

PILOTBURNER

FLP

FLO

PA

GASINLET

FLI

EV1

RP

EV2

MAINBURNER

PILOTBURNER

FLP

FLO

PA

MD

Fig. 1: schematic blocks.

1 ON-OFF solenoid EV1 terminals

2 ON-OFF solenoid EV2 terminals

3 Inlet pressure test point

4 Outlet pressure test point

5-a Pressure modulator device

5-b HI-LO pressure modulator device

5-c Electrical pressure modulator device

6 Pressure modulator device terminal

7 Pilot adjusting screw

8 Pilot outlet

9 Gas inlet with protective seal

10 Gas outlet with protective seal

11 Ground connection

12 Dead mounting holes

13 Throught mounting holes

5-b

Fig. 2: valve description.

5-c6

2

11

7

9

5-a

13

12

12

143

8

10

13

12

9955056_02(0�2)_��0-�-5_cat.indd2 2 2�/0�/2010 10.�5.5�

Page 3: proflaMe - Sit Group

valve GeNeRal DaTa

ConstruCtion CharaCteristiCs

• Aluminium alloy body• Inline inlet and outlet• Available bottom inlet and bottom outlet• Pilot outlet• Inlet filter

use speCifiCations

• Installation position Upright, ≤90° from upright ( Never upside down )• Gas families Natural Gas ,LPG• Ambient operating temperature range 32 to 175 °F• Maximum inlet pressure 1/2 psi• NOT for direct burner ignition appliances

MeChaniCal ConneCtions

• Gas inlet and outlet connections - 3/8”- 18 NPT ANSI B 1.20.1 - 5/8”- 18 SAE J512 - 9/16”- 24 UNEF ANSI B 1.1

• Pilot outlet 7/16“- 24 UNS - 2B ANSI

• Pressure test points ø9 mm

• Inlet pressure test point • Outlet pressure test point• Two mounting through holes on the side• Two mounting holes on the gas inlet and outlet

9955056_02(0�2)_��0-�-5_cat.indd� � 2�/0�/2010 10.�5.5�

Page 4: proflaMe - Sit Group

eleCTRONIC DIGITal FIRePlaCe BURNeR CONTROl DeSCRIPTION

It consists of a digital board that operates the solenoids of the shut-off valves.It controls the ignition of the pilot flame and the main burner flame.

eleCTRONIC DIGITal FIRePlaCe BURNeR CONTROl GeNeRal DaTa

ConstruCtion CharaCteristiCs

• Plastic box protection degree: IP00

use speCifiCations

• Installation position any• Ambient operating temperature range 0 to 175 °F

MeChaniCal ConneCtions

• Fixing points 4 dead holes ø 4 mm diameter and 8 mm depth or, optionally, 4 dead holes M5 threaded and 8 mm depth 2 throught holes ø 4 mm diameter

5

5

4

4

3

3

2

2

1

1

D D

C C

B B

A A

CN0

CN4

CN3

DIGITALFIREPLACE

BURNERCONTROL

CN2 CN1

Diagnostics/ BUZZER

4x1.5V BattERY sEt

Main on / oFFEV1EV2

cHassis / gRoUnD

VaLVE BoDY gRoUnD

7V Dc staBiLiZED sUPPLY

sPaRK RoD

FLaME sEnsoR RoD

cPi / iPi MoDE

Fig. 3: wiring diagram.

WARNINGTHE MOUNTING DEAD HOLES DEPTH IS SHOWN IN FIG. �. MAKE SURE TO USE SCREWS OF APPROPRIATE LENGHT. THE SCREWS MUST NOT PUSH THE BOTTOM OF THE MOUNTING HOLES.

9955056_02(0�2)_��0-�-5_cat.indd� � 2�/0�/2010 10.�5.5�

Page 5: proflaMe - Sit Group

5

eleCtriCal ConneCtions

• CN0 connector: Molex 4 way male• CN1 connector: Molex 9 way male• CN2 connector: 6.3x0.8 mm male faston• CN3 connector: 2.8x0.5 mm male faston• CN4 connector: 4.8x0.5 mm male faston

Fig. 4

MOUNTING HOLES

SECTION OF THE MOUNTING HOLES

7.5 [0.295] MIN

Ø 3

.6 [

Ø 0

.142

] (N

° 4)

MOUNTING HOLES

SECTION OF THE MOUNTING HOLES

7.5 [0.295] MIN

Ø 3

.6 [

Ø 0

.142

] (N

° 4)

Dimensions are in millimeters. Dimensions between [...] are in inches

9955056_02(0�2)_��0-�-5_cat.indd5 5 2�/0�/2010 10.�5.56

Page 6: proflaMe - Sit Group

6

valve FUNCTIONal DeSCRIPTION

The Proflame control is equipped with two automatic shut-off valves. It is possible to read the inlet pressure when both valves are de-energized (OFF in Fig. 6).

When the solenoid EV1 is energized the first gas valve opens. The pilot outlet is enabled (PILOT in Fig. 6).

When EV2 is energized the second valve opens and gas flows through the main outlet (OPEN in Fig. 6). It is possible to measure the outlet pressure on the outlet pressure test point.The servo pressure regulator system provides superior performance of outlet pressure regulation. The outlet pressure can be adjusted by a knob (Manual HI-LO version) or by a electrical modulator device.

valve CaPaCITY

Fig. 5: Flow rate vs. drop pressure.

floW rate Q as a funCtion of pressure Drop ∆p

880- Power test gas A [Kbtu/h, d=0.64, Hi=37.3 Mj/m3]-Pinlet=3,5["w.c.]-d pil = 0.3mm

0

10

20

30

40

50

60

70

80

90

100

110

120

0 0.5 1 1.5 2 2.5 3

P [

kb

tu/h

]

TEST GAS A

9955056_02(0�2)_��0-�-5_cat.indd6 6 2�/0�/2010 10.�5.56

Page 7: proflaMe - Sit Group

�Fig. 6: On/Off, Manual HI-LO, Electronic Modulation functional description

oFF

PiLot

INLET

EV1

PILOT

EV2

NOT ADJUSTABLE PRESSURE

REGULATOR

OUTLET

INLET

EV1

PILOT

EV2

OUTLET

oPEn

INLET

EV1

PILOT

EV2

OUTLET

NOT ADJUSTABLE PRESSURE

REGULATOR

NOT ADJUSTABLE PRESSURE

REGULATOR

OFF

PILOT

OPEN

OFF

PILOT

OPEN

OFF

PILOT

OPEN

OFF

PILOT

OPEN

ADJUSTABLE PRESSURE

REGULATOR (WITH STEPPER

MOTOR)

ADJUSTABLE PRESSURE

REGULATOR (WITH STEPPER

MOTOR)

ADJUSTABLE PRESSURE

REGULATOR (WITH STEPPER

MOTOR)

ADJUSTABLE PRESSURE

REGULATOR (WITH KNOB)

ADJUSTABLE PRESSURE

REGULATOR (WITH KNOB)

ADJUSTABLE PRESSURE

REGULATOR (WITH KNOB)

OFF

PILOT

OPEN

OFF

PILOT

OPEN

9955056_02(0�2)_��0-�-5_cat.indd� � 2�/0�/2010 10.�6.2�

Page 8: proflaMe - Sit Group

valve DImeNSIONal DRawING

notE: all the dimensions are expressed in millimeters [inches].

9955056_02(0�2)_��0-�-5_cat.indd� � 2�/0�/2010 10.�6.25

Page 9: proflaMe - Sit Group

9

SOSTITUIR

E CON �

��

valve DImeNSIONal DRawING

notE: all the dimensions are expressed in millimeters [inches].

9955056_02(0�2)_��0-�-5_cat.indd9 9 2�/0�/2010 10.�6.26

Page 10: proflaMe - Sit Group

10

valve DImeNSIONal DRawING

notE: all the dimensions are expressed in millimeters [inches].

[1.7]

[0.3]

[5.55]

[1.34]

[1.42]

[4.1]

[0.75]

[0.45][0.3]

[11.8]

9955056_02(0�2)_��0-�-5_cat.indd10 10 2�/0�/2010 10.�6.26

Page 11: proflaMe - Sit Group

11

DIGITal FIRePlaCe BURNeR CONTROl DImeNSIONal DRawING

notE: all the dimensions are expressed in millimeters [inches]

82 [3

.22]

36 [1

.42]

108 [4.25]

9955056_02(0�2)_��0-�-5_cat.indd11 11 2�/0�/2010 10.�6.2�

Page 12: proflaMe - Sit Group

sit controls Usa inc.900 Center Park Drive Suite J

Charlotte, NC 28217 USA

Ph. 704-522-6325, fax 704 522 7945www.sitcontrols.com – e-mail: [email protected]

9955056_02(0�2)_��0-�-5_cat.indd12 12 2�/0�/2010 10.�6.2�