+38% 1 Figures Specification 2014 PROFINET Jorey Guzman President RPA-SEA 2 PROFINET from PROFIBUS International The architecture is being devised by 12 work groups With 140 employees from 60 companies PROFINET – from the world's largest fieldbus organization PROFIBUS & PROFINET International (PI) More then 1,400 members world wide 27 Regional Associations (RPA) 50 PI Competence Center (PICC) 11 PI Test Laboratories (PITL) Intro RPA-SEA Installed Nodes Technological Development Specification Webpage
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
+38%
1
FiguresSpecification 2014PROFINET
Jorey GuzmanPresident RPA-SEA
2PROFINET from PROFIBUS International
The architecture is being devised by 12 work groupsWith 140 employeesfrom 60 companies
PROFINET – from the world's largest fieldbus organization
Develop Certified Competence & Training centers in the regions
Promote its members
Update the market on products, events & training
Intro RPA-SEA
Installed Nodes
TechnologicalDevelopment
Specification
Webpage
+38%
3
55New Corporate Design
Organization logoSouth East Asia
Technology logo
Profile logoPROFIdrivePROFIdrive
Intro RPA-SEA
Installed Nodes
TechnologicalDevelopment
Specification
Webpage
6Members of Southeast Asia
Cooperation's with following magazines:
Intro RPA-SEA
Installed Nodes
TechnologicalDevelopment
Specification
Webpage
+38%
4
Installed nodes World wide, new counting
PROFIBUS nodes
8
PROFIBUS device in Process Automation
+38%
5
9PROFINET nodes
10PN nodes count
10
5.8
4.3
3.0
2.11.6
1.14
+38%
+35%
20112010200920082007
+43%
+43%
+31%+40%
Mio
2012
+38%
6
11IMS Research Press Release
11
In its new study “The World Market for Industrial Ethernet & FieldbusTechnologies – 2013 Edition,” IMS Research confirms PROFINET a leading position, with a market share of 30%, among the globally established Industrial Ethernet solutions. The study describes the solution promoted by PI (PROFIBUS & PROFINET International) as a comprehensive Industrial Ethernet solution that covers all areas up to and including high-performance drives.
Besides PROFINET the leading group includes Ethernet/IP and ModbusTCP/IP. Together, this group covers more than three-quarters of the market. The EtherCAT and Powerlinkvariants, which focus mainly on drive technology, have a market share of 7% and 9%, respectively, according to the study (see graphic).
Among the three leaders, PROFINET has proven to be at the top in terms of future outlook. IMS Research forecasts a compound annual growth rate (CAGR) of +16.9% for PROFINET (compared to +14.8% for EtherNet/IP and 15.9% for Modbus TCP).
12PROFIsafe nodes
+38%
7
PROFINET @ VW Mexico
One cable for everything!2nd largest VW factory world wide
In 2010 only ~2.500 PROFINET devices
Today 10.000 devices in 150 stations
PROFINET & PROFIsafe are used throughout the plant
quality management and real-time data over the same wire
Relay – Switch • Switch signal is transmitted digital, additional parameters:
• Tag• Serial number• Device status• …Level switch 1983
- analogue Level switch 2013- PROFIBUS PA
Slide
22
+38%
12
Value for our customers
Additional process values: More information about the process
More accurate process values: Higher precision ensures high quality of product
Diagnostics: Reliable diagnostics enable effective maintenance and higher availability of the whole plant
Bi-Directional communication: Remote access to the device enables parameterization from a central station
Without digital communication, information is locked inside the device
Slide
23
24PA Profile 3.02
PROFIBUS PA Profile 3.02 focuses on easy device handling, such as…
Device handling similar to 4…20mA
Easy diagnostics
Easy device replacement
Easy life cycle management
24
Intro RPA-SEA
Installed Nodes
TechnologicalDevelopment
Specification
Webpage
+38%
13
2525Device Diagnostic with PA Profile
Process control, maintenance, condition monitoring, …
PROFIBUS PA
Device A Device CDevice B
Before profile 3.02 was introduced
all diagnosis messages have been provided to all users.>> Difficult to manage by the operators
2626Condensed Status & Diagnostic Messages
With Profile 3.02
Diagnosis messages are mapped to categories already by the manufacturer, categories comply with NAMUR NE 107.Plant operator gets categorized information.Maintenance department gets full information.
PROFIBUS PA
Device ADiag 1
Diag2
Diag 3
Diag 4
------
Diag n
Maintenance Required
Failure Functional Check
Out of Specification
Device ADiag 1
Diag2
Diag 3
Diag 4
------
Diag n
Device ADiag 1
Diag2
Diag 3
Diag 4
------
Diag n
Diag 1
Diag2
Diag 3
Diag 4
------
Diag n
Diagnosis messages are mapped to 4 categories.
Plant operatorMaintenance department
+38%
14
27PROFINET the comprehensive standard
FactoryAutomation
MotionControl
ProcessAutomation
PROFINETEstablished in factory automation and motion controlUsed in the process industry for inbound and outbound applications PROFINET standardized for the primary process