Professor Walter W. Olson Department of Mechanical, Industrial and Manufacturing Engineering University of Toledo PID Control.

Mar 29, 2015

Download

Documents

Jaelyn Painton
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
  • Slide 1

Professor Walter W. Olson Department of Mechanical, Industrial and Manufacturing Engineering University of Toledo PID Control Slide 2 Outline of Todays Lecture Review Margins from Nyquist Plots Margins from Bode Plot Non Minimum Phase Systems Ideal PID Controller Proportional Control Proportional-Integral Control Proportional-Integral Derivative Control Ziegler Nichols Tuning Slide 3 Margins Margins are the range from the current system design to the edge of instability. We will determine Gain Margin How much can gain be increased? Formally: the smallest multiple amount the gain can be increased before the closed loop response is unstable. Phase Margin How much further can the phase be shifted? Formally: the smallest amount the phase can be increased before the closed loop response is unstable. Stability Margin How far is the the system from the critical point? Slide 4 Gain and Phase Margin Definition Nyquist Plot Slide 5 Gain and Phase Margin Definition Bode Plots Positive Gain Margin Phase Margin -180 0 Phase, deg Magnitude, dB Phase Crossover Frequency Slide 6 Stability Margin It is possible for a system to have relatively large gain and phase margins, yet be relatively unstable. Stability margin, s m Slide 7 Non-Minimum Phase Systems Non minimum phase systems are those systems which have poles on the right hand side of the plane: they have positive real parts. This terminology comes from a phase shift with sinusoidal inputs Consider the transfer functions The magnitude plots of a Bode diagram are exactly the same but the phase has a major difference: Slide 8 Another Non Minimum Phase System A Delay Delays are modeled by the function which multiplies the T.F. Slide 9 Proportional-Integral-Derivative Controller Based on a survey of over eleven thousand controllers in the refining, chemicals and pulp and paper industries, 97% of regulatory controllers utilize PID feedback. L. Desborough and R. Miller, 2002 [DM02]. PID Control, originally developed in 1890s in the form of motor governors, which were manually adjusted The first theory of PID Control was published by a Russian (Minorsky) who was working for the US Navy in 1922 The first papers regarding tuning appeared in the early 1940s Today. there are several hundred different rules for tuning PID controllers (See Dwyer, 2003, who has cataloged the major methods) While most of the discussion is about the ideal PID controller, there are many forms of the PID controller Slide 10 PID Control Advantages Process independent The best controller where the specifics of the process can not be modeled Leads to a reasonable solution when tuned for most situations Inexpensive: Most of the modern controllers are PID Can be tuned without a great amount of experience required Disadvantages Not optimal Can be unstable unless tuned properly Not dependent on the process Hunting (oscillation about an operating point) Derivative noise amplification Slide 11 The Ideal PID Controller The input/output realtionship for the PID Controller is the Integral-Differential Equation The ideal PID controller has the transfer function Structurally it would look like + + + + - Slide 12 The Ideal PID Controller The system transfer function is + + + + - Slide 13 Proportional Control R(s) Y(s) + + + + - Slide 14 Proportional Control Slide 15 Proportional Controller k p =7.2 Slide 16 Proportional Controller With k p =7.2, We could reduce the error with a prefilter: } Error Also: the response time is poor + + + + + 0.139 R(s) Y(s)= (s) Slide 17 Proportional Integral Controller Most controllers using this technology are of this form: This reacts to the system error and reduces it R(s) Y(s) + + + + - Slide 18 Proportion-Integral Control Applying PI control to the F-16 Elevator, Response time improved with no error Slide 19 Proportional- Integral-Derivative Control The derivative component is rarely used. Reduces overshoot May slows the response time depending on the system Sensitive to noise For the F-16 Elevator Slide 20 PID Tuning Tuning is the choosing of the parameters k d, k i, and k p, for a PID Controller The oldest and most used method of tuning are the Ziegler- Nichols (ZN) methods developed in the 1940s. The first method is based on the assumption that the process without its feedback loop performs with a 1 st order transfer function, perhaps with a transport delay The second method assumes that a higher order system has dominant poles which can be excited by gain to the point of steady oscillation In order to establish the constants for computing the parameters simple tests are performed of the process Slide 21 Ziegler-Nichols PID Tuning Method 1 for First Order Systems A system with a transfer function of the form has the time response to a unit step input: This response might also be generated from a higher order system that is has high damping. Slide 22 Ziegler-Nichols PID Tuning Method 1 for First Order Systems The advice given is to draw a line tangent to the response curve through the inflection point of the curve. However, a mathematical first order response doesnt have a point of inflection as it is of the form (at no place does the 2 nd derivative change sign.) My advice: place the line tangent to the initial curve slope Adjust the gain K of the system by multiplying compensator by 1/K Lag L Rise Time T Typekpkp TiTi TdTd P PI PID Slide 23 Ziegler-Nichols PID Tuning Method 1 for First Order Systems For this example, Typekpkp TiTi TdTd P PI PID Lag L Rise Time T Slide 24 Ziegler-Nichols PID Tuning Method 2 for Unknown Oscillatory System The form of the transfer function unknown but the system can be put in steady oscillation by increasing the gain: Increase gain, K, on closed loop system until the gain at steady oscillation, K cr, is found Then measure the critical period, P cr Apply table for controller constants and multiply by system gain 1/K 1 Cycle P cr Typekpkp TiTi TdTd P PI PID Slide 25 Ziegler-Nichols PID Tuning Method 2 Example 1.0 1 Cycle 17.8 P cr Typekpkp TiTi TdTd P PI PID k=1000 k=2000 k=1500 k=1750 K cr =1875 Slide 26 Ziegler-Nichols PID Tuning Method 2 Example 1.0 1 Cycle 17.8 P cr K cr =1875 Slide 27 Summary Ideal PID Controller Proportional Control Proportional-Integral Control Proportional-Integral Derivative Control Ziegler-Nichols Tuning Next Class: PID Controls Continued