Page 1: PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.

PRODUCTSTRANSFORMERS

ENERGY SAVING TRANSFORMERS (EST)

TRANSFORMER RECTIFIER UNITS

3rd HARMONIC REJECTION TRANSFORMERS (HRT)

ULTRA HIGH ISOLATION TRANSFORMERS (TRX)

CONSTANT VOLTAGE TRANSFORMERS (CVT/VCT/HST)

VARIABLE UNITS

Page 2: PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.

TRANSFORMERS

AUTO WOUND

NON ISOLATED SUPPLY

NORMALLY USED FOR TRANSFORMING VOLTAGES WITHIN A SMALL MARGIN OF THE INCOMING MAINS

ie: 100 KVA UNIT, 415 VOLTS TO 380 VOLTS

EQUIVALENT FRAME SIZE WOULD BE 8.4KVA

Page 3: PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.

AUTOWOUND

Page 4: PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.

TRANSFORMERSDOUBLE WOUND

ISOLATED SUPPLY

INPUT AND OUTPUT ELECTRICAL SEPARATE

ANY VOLTAGE RANGE

Page 5: PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.

DOUBLE WOUND

Page 6: PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.

VARIATIONS AUTOWOUND (A.W.) OR DOUBLE WOUND (D.W.)

INPUT VOLTS AND TAPPINGS

FREQUENCY 50Hz OR 60Hz OR BOTH OR OTHER?

CURRENT RATING OR KVA

OUTPUT VOLTS AND TAPPINGS

FREQUENCY 50Hz OR 60Hz OR BOTH OR OTHER?

CURRENT RATING OR KVA

Page 7: PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.

VARIATIONSNUMBER OF PHASES

SINGLE PHASE (generally Line to Neutral volts)

2 PHASE (Generally the same as single phase except across two lines ie: 415 volts)

3 to 2 PHASE (SCOTT CONNECTED)

3 to 1 PHASE

3 PHASE (Vector group or connection ie: DYn11, DYn1, Dd0 etc this information tell us how to connect the windings and work out the currents in the phase’s

Page 8: PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.

VARIATIONSCOOLING MEDIUM

NATURALLY AIR COOLED

OIL COOLED

FORCED AIR COOLED

AMBIENT TEMPERATURE ( this will govern the temperature rise in the coil for the Class of insulation)

Temperature rise Class ( O, A, E, F, H, C)

Insulation Class ( O, A, E, F, H, C)

Page 9: PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.

VARIATIONS

OPEN TYPE OR ENCLOSED

ENCLOSED TYPE IP PROTECTION RANGE FROM IP22 TO IP54

IP65 NORMALLY QUOTE AS OIL IMMERSED

OTHER FURNITURE ie: FUSES, METERS TAP CHANGING SWITCHES, ISOLATOR SWITCHES, CONTACTORS, REGAVOLTS? Etc.

Page 10: PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.

VARIATIONS

ALL TRANSFORMERS ARE BUILT TO BS OR IEC SPECIFICATIONS

BS 171 POWER TRANSFORMERS

BS 3535 ISOLATING TRANSFORMERS

BS EN 60076-1 & -2 POWER TRANSFORMERS

IEC 61558 pt 2.1 , 2.4, 2.6 SAFETY OF POWER TRANSFORMERS

BS EN 60601 / BS5724 MEDICAL ELECTRICAL EQUIPMENT

JUST SOME OF THE MANY THAT MAY BE QUOTED

Page 11: PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.

VARIATIONS

“CE” BADGING EN61010 (1993)

AS PART OF THE “EMC” AND “LVD” DIRECTIVES ALL EQUIPMENT THAT IS HOUSED AND FITTED WITH AUXILLIARY EQUIPMENT IS REQUIRED TO BE “CE” BADGED AND A DECLARATION OF CONFORMITY ISSUED.

Page 12: PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.
Page 13: PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.
Page 14: PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.

ENERGY SAVING

PRINCIPAL OBJECT OF THE PRODUCT IS TO REDUCE INPUT VOLTS

MOST MODERN EQUIPMENT IS SUITABLE TO WORK FROM 207 / 254Volts

THEREFORE THE NEARER TO THE EQUIPMENTS OPTIMUM OPERATING VOLTAGE THE LESS CURRENT IS BEING USED.

BENEFITS INCLUDE LESS POWER CONSUMPTION LOWER ELECTRICITY BILLS, LONGER LIFE OF EQUIPMENT

Page 15: PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.

ENERGY SAVING

TWO SOLUTIONS TO THE SAME PROBLEM

EST = ENERGY SAVING TRANSFORMER

LIMITATIONS

FIXED TAPPING STEPS

UNIT FOLLOWS MAINS FLUCTUATIONS SO IF NORMAL VOLTS FALL THE STEP DOWN VOLTAGE FALLS AS WELL LEADING TO POSSIBLE PROBLEMS THEREFORE MAXIMUM VOLT DROP 8/9%

NORMAL VOLT DROPS ARE 3% 5% 7%

Page 16: PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.

ENERGY SAVING

ESS = ENERGY SAVING STABILISER

CAN STEP VOLTAGE DOWN LOWER THAN (EST) OUTPUT VOLTAGE REMAINS STABLE REGARDLESS OF MAINS FLUCTUATIONS (WITHIN SET PARAMETERS 12.5% approx, THEN IT WILL TRACK MAINS)

ADDED BENEFIT OF KEEPING EACH PHASE INDEPENDENTLY CONSTANT, WHICH CAN ADD TO MOTOR LIFE

Page 17: PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.

ENERGY SAVINGENERGY SAVING UNITS WILL NOT WORK ON ALL LOADS?

SWITCH MODE POWER SUPPLIES ie ( COMPUTER SUPPLIES)

HIGH FREQUENCY BALLAST LIGHTING ?????

Page 18: PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.

HRT

3RD HARMONIC REJECTION TRANSFORMERS

NON LINEAR LOADS GENERATE HARMONICS

DESIGNED TO ELIMINATE PRIMARILY MULTIPLES OF THE 3RD HARMONICS AND SOME OF THE 5THS

Page 19: PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.

HRT

PRODUCT BENEFITS

EASE OF INSTALLATION (can be installed without switching off the supply as fitted in parallel)

REDUCES HARMONICS

REDUCES NEUTRAL CURRENT (high neutral currents can burn out transformers that have not been designed for the purpose, and more consumption of power)

REDUCES PHASE CURRENTS

REDUCES TRANSFORMER OVERLOADING

Page 20: PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.
Page 21: PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.
Page 22: PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.
Page 23: PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.
Page 24: PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.

TRX

ULTRA HIGH ISOLATION TRANSFORMERS

DESIGNED TO PROTECT COMPUTERS AND OTHER SENSITIVE EQUIPMENT FROM VOLTAGE TRANSIENTS, SPIKES, NOISE etc.

Page 25: PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.

TRXTYPICAL SPECIFICATION

TRANSIENT SUPPRESSION

COMMON MODE 88dB

TRANSVERSE MODE 65dB

NOISE SUPPRESSION

COMMON MODE 120dB

TRANSVERSE MODE 65dB

SINGLE PHASE OR 3 PHASE UNITS AVAILABLE

Page 26: PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.

CONSTANT VOLTGE CVT/VCT/HST

WILL SUPPLY A REGULATED OUTPUT VOLTAGE REGARDLESS OF MAINS FLUCTUATIONS

SHORT CIRCUIT PROOF ALMOST INDESTRUCTABLE

HAS A LIMITED STORAGE CAPACITY FOR A PERIOD OF HALF CYCLE

Page 27: PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.

CONSTANT VOLTAGE CVT/VCT/HST

INPUT VOLTAGE TOLERANCE +-15%

OUTPUT ACCURACY +-3%

WAVEFORM REMAINS SINOSOIDAL WITH LESS THAN 3% HARMONIC DISTORTION

EFFICIENCY GREATER THAN 80%

FREQUENCY MUST BE 50Hz OR 60Hz

AVAILABLE IN VOLTAGES FROM 110 – 440 VOLTS

AVAILABLE IN SINGLE PHASE OR 3 PHASE

THERE IS A LIMITATION ON SIZE???

Page 28: PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.
Page 29: PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.

TRANSFORMER RECTIFIERS

TYPICAL UNITS WILL BE SINGLE PHASE BRIDGE RECTIFIED OR 3 PHASE BRIDGE RECTIFED

SINGLE PHASE BRIDGE RECTIFIER

TYPICAL RIPPLE CONTENT 48%

CAN BE SMOOTHED VIA CHOKE / CAPACITOR CIRCUIT TO APPROX 5-10%

MAY INCREASE OFF LOAD VOLTAGES (so information concerning maximum off load volts may be required)

Page 30: PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.

TRANSFORMER RECTIFIERS

Page 31: PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.

TRANSFORMER RECTIFIERS

3 PHASE BRIDGE RECTIFER

TYPICAL RIPPLE CONTENT 5%

Page 32: PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.

TRANSFORMER RECTIFIERSRIPPLE CONTENT CAN BE LOWERED BY SIX PHASE (12 PULSE RECTIFIER UNITS) TYPICAL RIPPLE CONTENT 1%

Page 33: PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.

VARIABLE UNITS

A CLAUDE LYONS VARIABLE CAN BE ADDED TO THE MAJORITY OF THE TRANSFORMERS (auto and double wound) DISCUSSED, AND RECTIFIER UNITS.

THERE ARE LIMITATIONS

THE REGAVOLT IS MANUFACTURED IN STRICT CURRENT CARRYING CAPACITY MODELS, TO INCREASE THIS CAPABILITY MULTIPLE MODELS ARE GANGED TOGETHER SO LIMITATIONS ARE PURELY PHYSICAL.

Page 34: PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.

VARIABLE UNITS

TO OVERCOME THIS OTHER ALTERNATIVE’S CAN BE OFFERED

A BUCK/BOOST UNIT WHERE THE CUSTOMER ONLY WISHES TO VARY A SMALL AMOUNT AROUND A VOLTAGE

A TAPPED BUCK/BOOST UNIT WHERE THE CUSTOMER WISHES ZERO TO (X) VOLTS A FIXED TRANSFORMER IS TAPPED IN EQUAL STEPS SELECTED VIA A SWITCH AND A SMALLER VARIABLE TRANSFORMER IS CONNECTED IN SERIES WITH THE OUTPUT.

Page 35: PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.
Page 36: PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.