Top Banner
PRODUCT SPECIFICATIONS MLDV500 Winchester Direct Vent 42 1/2" 73" 1/2" OR 5/8" 22 1/4" 14 3/4" 32 1/2" 51 1/2" 36 1/2" 30 7/8" 20 5/8" 7 3/4" 22 1/4" FRAMING DIM. 42 1/2" FRAMING DIM. 22 5/16" 42 1/16" 6" 9 11/16" 34" 50 13/16" 3 1/8" 1" 2 1/2" 36" 41" 33" 27 5/16" 1 3/8" 14 1/2" 44 9/16" 38 3/4" To avoid personal injury or property damage, the product described by this brochure must be installed, operated and maintained in strict compliance with the instructions packaged with the product and all applicable building or fire codes. Contact local building or fire officials about restrictions and installation inspection requirements. All photographs and drawings on this brochure are for illustrative purposes only and are not intended A Brand of Monessen Hearth Systems Co. 149 Cleveland Drive, Paris, Kentucky 40361 www.monessenhearth.com GLASS VIEWING AREA 33”W x 25-13/16”H 902 Square Inches TECHNICAL INFORMATION Max. Btu Input: 34,000 BTU/HR Ignition System: Signature Command™ System Gas Type: Natural or LP Flue Type: Simpson Dura-Vent, Selkirk Metalbestos, MetalFab Termination: Rear/Top Vent Convertible Clearance to Flue for Interior: 3" Top, 1" Bottom and Sides** Clearance to Flue for Outside Wall: 1" Clearance to Fireplace: 0" Minimum Vent Height Before Elbow: 12” CSA Design Certified FIELD INSTALLED ACCESSORIES Louvers: Brass, Pewter Firebrick: Cottage Clay, Cottage Red or Vintage Brown Variable Thermostat Controlled Dual Forced Air Blower (160 cfm) – BLOTBLDV Signature Command System Dual Forced Blowers (160 cfm) BLOTBLDVSC Mesh Glass Cover Andirons Field Conversion Kits Ambient Technologies Remote Controls and Thermostats **If vertical rise is 7-1/2 feet or higher when in top vent configuration only, the vent clearance to combustibles is 1” on all sides of the horizontal run. MADE IN U.S.A.
1

PRODUCT SPECIFICATIONS MLDV500 Winchester Direct Vent MLDV500 Spec.pdfPRODUCT SPECIFICATIONS MLDV500 Winchester Direct Vent 42 1/2" 73" 1/2" OR 5/8" 22 1/4" 5 1 2" 32 1/2" 14 3/ 4"

May 25, 2019

Download

Documents

ngoquynh
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: PRODUCT SPECIFICATIONS MLDV500 Winchester Direct Vent MLDV500 Spec.pdfPRODUCT SPECIFICATIONS MLDV500 Winchester Direct Vent 42 1/2" 73" 1/2" OR 5/8" 22 1/4" 5 1 2" 32 1/2" 14 3/ 4"

PRODUCT SPECIFICATIONS

MLDV500 Winchester Direct Vent

42 1/2"

73"

1/2" OR 5/8"

22 1/4"

14 3/4"32 1/2"51 1/2"

36 1/2"

30 7/8"

20 5/8"

7 3/4"

22 1/4"FRAMING DIM.

42 1/2"FRAMING DIM.

22 5/16"

42 1/16"

6"

9 11/16"

34"

50 13/16"

3 1/8"

1"

2 1/2"

36"

41"

33"

27 5/16"

1 3/8"

14 1/2"

44 9/16"

38 3/4"

To avoid personal injury or property damage, the product described by this brochure must be installed, operated and maintained in strict compliance with the instructions packaged with the product and all applicablebuilding or fire codes. Contact local building or fire officials about restrictions and installation inspection requirements. All photographs and drawings on this brochure are for illustrative purposes only and are not intended

A Brand of Monessen Hearth Systems Co.149 Cleveland Drive, Paris, Kentucky 40361

www.monessenhearth.com

G L A S S V I E W I N G A R E A33”W x 25-13/16”H 902 Square Inches

T E C H N I C A L I N F O R M AT I O NMax. Btu Input: 34,000 BTU/HRIgnition System: Signature Command™ SystemGas Type: Natural or LPFlue Type: Simpson Dura-Vent, Selkirk Metalbestos, MetalFabTermination: Rear/Top Vent ConvertibleClearance to Flue for Interior: 3" Top, 1" Bottom and Sides**Clearance to Flue for Outside Wall: 1"Clearance to Fireplace: 0"Minimum Vent Height Before Elbow: 12”CSA Design Certified

F I E L D I N S TA L L E D A C C E S S O R I E SLouvers: Brass, PewterFirebrick: Cottage Clay, Cottage Red or Vintage BrownVariable Thermostat Controlled Dual Forced Air Blower (160 cfm) – BLOTBLDVSignature Command System Dual Forced Blowers (160 cfm) –BLOTBLDVSCMesh Glass CoverAndironsField Conversion KitsAmbient Technologies™ Remote Controls and Thermostats

**If vertical rise is 7-1/2 feet or higher when in top vent configuration only, the ventclearance to combustibles is 1” on all sides of the horizontal run.