Product Release Letter For further information please contact your local AVEVA support office, which can be found at http://support.aveva.com This document has been prepared and approved by the following: Job Title Name Product Manager Stephen Burrows Test Manager Vaseem Jameel Head of Product Gavin Watton TPS Manager Semra Hamitogullari File: d52326.doc Last saved: 26-Jan-2015 Copyright 2015 AVEVA Solutions Limited Page 1 of 25 AVEVA Everything3D™ 1.1.0.21 Partial Fix Release 52326 Windows 7 This letter introduces and describes this release, which is supported on the indicated platform(s). This Release Contains A partial release of AVEVA Everything3D™, which upgrades the full release 52072 AVEVA Everything3D™ 1.1 The separately licensed products or product components installable from or upgraded by this release are as follows: Product Code Product Name Version Number V00FN201 AVEVA Everything3D™ 1.1.0 V00FN231 AVEVA Administration™ 1.1.0 V00FN232 AVEVA Catalogue™ 1.1.0 Prerequisite for this release - operating system: Minimum Supported O/S Version (for each supported platform) Windows 7 (64-bit preferred) with Microsoft .NET Framework 4.0 (supplied) Mandatory O/S Patches (for each supported platform) Windows 7 – Service Pack 1 Build Operating System Windows Server 2008 R2* * AVEVA supports the use of Windows Server 2012 R2 as a file server for projects deployed with AVEVA Everything3D™ 1.1 and associated products. Please note that recommended/supported hardware and software configurations are constantly subject to review, so please consult the AVEVA support web pages for the latest recommendations.
25
Embed
Product Release Letter - Avevadownloads.aveva.com/52326/d52326.pdf · Product Release Letter ... AVEVA Plant 12.1.SP2 or 12.1.SP4 – Databases used by AVEVA PDMS 12.1.SP2.12 onwards
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Product Release Letter
For further information please contact your local AVEVA support office, which can be found at http://support.aveva.com
This document has been prepared and approved by the following:
Job Title Name
Product Manager Stephen Burrows
Test Manager Vaseem Jameel
Head of Product Gavin Watton
TPS Manager Semra Hamitogullari
File: d52326.doc
Last saved: 26-Jan-2015 Copyright 2015 AVEVA Solutions Limited Page 1 of 25
AVEVA Everything3D™ 1.1.0.21
Partial Fix Release 52326
Windows 7 This letter introduces and describes this release, which is supported on the indicated platform(s).
This Release Contains
A partial release of AVEVA Everything3D™, which upgrades the full release 52072 AVEVA Everything3D™ 1.1 The separately licensed products or product components installable from or upgraded by this release are as follows:
Product Code Product Name Version Number
V00FN201 AVEVA Everything3D™ 1.1.0 V00FN231 AVEVA Administration™ 1.1.0
V00FN232 AVEVA Catalogue™ 1.1.0
Prerequisite for this release - operating system:
Minimum Supported O/S Version (for each supported platform)
Windows 7 (64-bit preferred) with Microsoft .NET Framework 4.0 (supplied)
Mandatory O/S Patches (for each supported platform)
Windows 7 – Service Pack 1
Build Operating System Windows Server 2008 R2*
* AVEVA supports the use of Windows Server 2012 R2 as a file server for projects deployed with AVEVA Everything3D™ 1.1 and associated products.
Please note that recommended/supported hardware and software configurations are constantly subject to review, so please consult the AVEVA support web pages for the latest recommendations.
d52326.doc 26/01/2015 Copyright 2015 AVEVA Solutions Limited Page 2 of 25
Prerequisite for this release - products:
Full release 52072 AVEVA Everything3D™ 1.1
AVEVA Licensing System 1.0 or later and an appropriate License File. Notes:
For customers who use AVEVA E3D Insight™: You must have AVEVA Mobile Applications Service 1.2.3 or higher. Earlier versions are incompatible.
1. This version of AVEVA Everything3D™ does NOT work with AVEVA Flexman.
2. If upgrading from AVEVA Licensing System 1.1.1, please install Fix release 1.1.1.3 in order to correct an uninstall defect in that release. Once this has been done version 1.1.1.3 can be uninstalled and replaced with later versions.
Microsoft Office 2010 (32-bit) is required for some functions:
Optimum operation of the AVEVA Design Platform GUI requires Arial Unicode MS font, supplied with Microsoft Office (2000 onwards) and also with Microsoft Office Visio.
Microsoft Office Excel import requires “.NET Programmability Support” enabled when Office is installed. This can be found under “Advanced customization of applications” and installs the Microsoft.Office.Interop.Excel.dll; without this, Excel import will not work.
Microsoft Office Visio 2010 (Standard edition, 32-bit) is required for AVEVA Schematic Model Viewer.
To get the performance benefits given by the AVEVA Cache Service, which is installed with AVEVA Everything3D™, you need to enable Microsoft Message Queuing (MSMQ). This is achieved using the Windows Components feature of Windows Control Panel > Add or Remove Programs.
For full details, please refer to the AVEVA Everything3D™ 1.1 Installation Guide.
Works (is compatible) with:
AVEVA Plant 12.1.SP2 or 12.1.SP4 – Databases used by AVEVA PDMS 12.1.SP2.12 onwards (includes
data from AVEVA Engineering and AVEVA Diagrams 12.1 & 14.1) but NOT including the AVEVA Hull & Outfitting 12.1.SP3 ‘optional upgrade’.
AVEVA Global 12.1.SP3 or SP4 (SP4 recommended)
AVEVA Pipe Stress Interface 1.1
AVEVA PML Publisher 1.1 or 2.1
AVEVA Instrumentation 12.1.SP1
AVEVA Electrical 12.1.SP1
AVEVA Review 12.2
AVEVA Clash Manager 12.1
AVEVA PDMS VPRM Gateway 5.4
AVEVA Bocad Steel Interface 1.1 or 2.1 (2.1 recommended)
AVEVA E3D Insight™ 1.2.3 via AVEVA Mobile Applications Service 1.2.3
Supersedes:
This release supersedes Release 52316 – AVEVA Everything3D™ 1.1.0.20.
Product Release Letter
d52326.doc 26/01/2015 Copyright 2015 AVEVA Solutions Limited Page 3 of 25
To Install product release:
Please download the release (52326.zip) and run the product install (Folder E3D11021, Plant1.1.0.21.exe) following the instructions.
Sample projects (AVEVA Everything3D™ - Projects) are available here:
These AVEVA sample projects are regularly revised – please check the AVEVA Support Site (AVEVA Everything3D™ - Fix Release History) frequently for updates.
First released on:
This product release is first available on AVEVA support website http://support.aveva.com as AVEVA Everything3D™ 1.1.0.21, release number 52326.
List of Enhancements
This release includes the following functional enhancements: In this release None
Consolidated from previous fix releases: First released in Fix Version 1.1.0.9, Release No. 52211 Compatibility with AVEVA E3D Insight™
First released in Fix Version 1.1.0.7, Release No. 52195 Enhancments to Cable Design:
Description
AVEVA Electrical & AVEVA Instrumentation use a Cable Status flag in cable schedule screens. This indicates if the cable is estimated in route length, routed in AVEVA E3D, locked down for construction or requires revalidating, due to route changes being notified from E3D. E3D has an extended scope for cable status on the CABLE element:
Number Status 0 Un-routed 1 Routed 2 Routing Failed 3 Partially Routed 4 Partially Failed 5 Manually Routed 6 Routed and Drummed 7 Routed and Drummed and drum is locked 8 Check Route
A new pseudo attribute CBSTT holds descriptive text instead of number.
The existing pseudo attributes LALCAB and CLIST were extended to take cable status as extra qualifier. This allows the user to query all cables with a given status (eg. routed) on the cableway branch or on the RNODE. Querying LALCAB and CLIST without a qualifier attribute gives the same answer as previous releases (all cables).
There is a new Form for creation or modification of Route Nodes for a list of Cableway Branches, accessed by:
d52326.doc 26/01/2015 Copyright 2015 AVEVA Solutions Limited Page 4 of 25
First released in Fix Version 1.1.0.4, Release No. 52180 Some minor enhancements – internal test only
First released in Fix Version 1.1.0.2, Release No. 52168
Description
(SI-54970/#91995) E3D 1.1 Draw (Delete Function) - Requirement for "Delete Element members" command
(SI-54974/#91993) E3D 1.1 Draw (User Interface) - Sheet tab should reference Sheet Name not Title
First released in Fix Version 1.1.0.1, Release No. 52144
Description
Improved control buttons on Model 3D view windows – hover over to open up full menu of buttons
Search form now shows the number of items found and is also available in Isodraft
(SI-37521) Improved handling of messages at start-up
Diagram Change Highlighting as a new Fluent User Interface (see below).
It can be invoked from the Schematic Explorer or the Integrator Diagram Viewer.
Product Release Letter
d52326.doc 26/01/2015 Copyright 2015 AVEVA Solutions Limited Page 5 of 25
List of Fault Corrections
This release addresses defects arising from the following support incidents: In this release: First released in Fix Version 1.1.0.21, Release No. 52326
Incident
number
Defect
number
Product /
Module Description
151055 Draw
Title: Symbolic labels ignore visual layers defined in the symbol template. Symptoms: After setting up a symbol template with primitives that reference visual layers in the template, inserting labels for this template into a sheet ignores the template layers, changing the colours and linetypes of the label to the current label layer. Known workaround: To retain template colours and linetypes, explicit values must be used in the template, template layers cannot be used. Solution: Labels on drawings now respect the visual layers from the label template, as long as the corresponding label attributes are 'bytemplate' (or 'bystyle' with the style attributes set to 'bytemplate'). This is normally the default. Note that setting the label attributes to 'bylayer' overrides the template and forces the use of the colour and linestyle of the appropriate local sheet layer, as do explicit values (replicating the behaviour from before this issue was fixed). The label attributes in question are 'frame colour', 'frame linetype', 'text colour'. Note that the visibility/printability of the current sheet layer for the label applies to the label regardless.
63093 115385 Everything3D
Title: Modify of the Clipping-Planes not possible - Form disappears / Clipping on-off is not corresponding. Symptoms: Clipping form disappears and prevents manipulation of existing Clipping. Disparity in Clipping feedback between form and fluent user interface. Known workaround: Repeat operation. Solution: Fixed – form is presented and clipping feedback is synchronised.
70466 142973 Draw
Title: Visual Layers revert to 0 on copying Symbol Templates or creating a Sheet / Drawing from a Template. Symptoms: When copying Symbol Templates or Sheets/Drawings (this includes creating a Sheet/Drawing from a Template), Visual Layer references in the hierarchy revert to 0. This is despite the fact that the Visual Layers are copied. Known workaround: Visual Layer references have to be reset manually. Solution: Elements which reference Visual Layers are now copied without losing the Visual Layer references. The Layers are automatically reset to point at the new owner to ensure correct colours and linestyles are retained. Please note that when copying an element into a picture which already has a Visual Layer with the same title, the Visual Layer of the new picture is referenced. This is as designed.
71606 145271 Everything3D
Title: Collection Key query generates a "System" error. Symptoms: System error generated and not all collections can be accessed. Known workaround: None. Solution: Fixed - Collection Key query does not generate a "System" error.
Product Release Letter
d52326.doc 26/01/2015 Copyright 2015 AVEVA Solutions Limited Page 6 of 25
Consolidated from previous fix releases: First released in Fix Version 1.1.0.20, Release No. 52316
Incident
number
Defect
number
Product /
Module Description
67407 129970 Everything3D
Title: Navigation to reference object with collection. Symptoms: Navigation from reference in collection results in an error. Known workaround: None. Solution: Fixed.
67412 61638
129972 112161
Everything3D
Title: Not possible to display TUBI in the grid of a collection or a search. Symptoms: TUBI elements not listed by the Search utility. Known workaround: None. Solution: Fixed - TUBI elements are now listed by the Search utility.
65515 129109 Everything3D
Title: Clipping Form collapses on redefining Clipping via the Slider. Symptoms: Clipping Form disappears on using the Slider to redefine Six Plane Clipping. Known workaround: Repeat operation. Solution: Fixed.
53292 87928 Everything3D
Title: Global - Extract Issue may not Release elements if there is nothing to Extract Flush. Symptoms: Affects Global projects only. Known workaround: Use EXTRACT RELEASE to release the required elements. Solution: Fixed.
65141 121566 Draw
Title: Draw Canvas - Zoom extents does not work if there is no write access to the Database. Symptoms: Zoom and pan operations are not possible in the Draw Canvas. Known workaround: None. Solution: Fixed - new check has been implemented that checks not only if an element has a locked attribute but also checks if an element is read only.
69148 137654 Piping
Title: Using the Pipe Editor form to connect a Branch to a four-way Valve shows an incorrect error message on the form. Symptoms: Clicking on a valid Head/Tail connection, connected to a VFWA, resulted in a spurious warning message indicating that the branch was invalid and needed to be reconnected. Known workaround: None. Solution: The Pipe Editor form now considers VTWA elements correctly.
64841 120781 Piping
Title: Graphical setting scenario whereby TUBEs are incorrectly invisible. Symptoms: Setting graphical settings to Tube=On, Insu=Solid, OBST=12~87 cause TUBEs to be invisible. Known workaround: None. Solution: Fixed - identified graphical setting is now interpreted correctly.
67684 131187 Everything3D
Title: Point selection within the Positioning Control toolbar is incorrect on starting the application. Symptoms: On starting the application the Element option is selected. Known workaround: Pick the required option. Solution: Fixed.
First released in Fix Version 1.1.0.19, Release No. 52312
Incident
number
Defect
number
Product /
Module Description
Product Release Letter
d52326.doc 26/01/2015 Copyright 2015 AVEVA Solutions Limited Page 7 of 25
Incident
number
Defect
number
Product /
Module Description
106596 Draw
Title: Application crashes when attempting to delete a Stepped Section using the "delete step” option in the 3D View. Symptoms: Application aborts. Known workaround: Delete the Stepped Section by an alternative method. Solution: Crash is prevented by code dereferencing a null pointer.
68683 135989 Draw
Title: Unable to create an Isodraft Symbol Template unless a Free User. Symptoms: Unable to utilise the Isodraft Symbol Template creation User Interface within the Project tab when User is added to an ‘ADMIN’ team. Known workaround: Access the Project as a Free User. Solution: ADMIN team members are now able to create Templates via the Project tab.
71228 143697 Draw
Title: DESSYM elements are not exported to .Dwg/.Dxf format. Symptoms: The DESSYM element is not exported to any CAD export format. Known workaround: None. Solution: Fix introduces the correct export of DESSYM elements.
145342 Draw
Title: Fatal Error on selecting the ‘More’ option from the Rep & Hatch style form followed by Cancel. Symptoms: Fatal Error. Known workaround: Avoidance of described workflow. Solution: Fixed – described workflow can be completed.
145612 Everything3D
Title: Application can be slow to start on using Model Changes addin. Symptoms: Application can be slow to start if Model Changes addin was shown previously on a project with a large total number of database sessions. Known workaround: Close the Model Changes addin before closing the application. Solution: Model Changes addin is always hidden on application start; an upper-bound on the time taken to open the addin has been implemented.
146915 Draw
Title: Problem with Section Planes persisting between 3D Views. Symptoms: Section plane graphics persist when moving between 3D Views in canvas. Known workaround: None. Solution: Fixed – rogue Section Planes are no longer evident in Draw 3D View(s).
116590 Draw
Title: Handling of Section Plane toggles in 3D View tab 'Define Limits' and the 3D View. Symptoms: Section Planes are not always removed from the 3D View on using the Define Limits group of the 3D View tab. Known workaround: None. Solution: Fixed – Section Plane behaviour as defined by the Define Limits group and as shown by the 3D View has been corrected.
66223 125452 Draw
Title: Loss of GPWL from Drawlist when exiting the 3D View. Symptoms: Remove (REME) rules after adding a Group World are lost after entering and exiting the 3D View. Known workaround: None. Solution: The bug occurred because the elements below a Group World are not necessarily owned by it; they may only be referenced. This has been rectified so that both ownership and references are checked.
66245 125631 IsoDraft
Title: Spooler MTO object fails on querying P-Point bore sizes when run embedded in a bolt report template. Symptoms: Error on attribute PPBore. Known workaround: None. Solution: Fixed check for 3rd and 4th bores to cope with extra ppoints in piping catalogue.
Product Release Letter
d52326.doc 26/01/2015 Copyright 2015 AVEVA Solutions Limited Page 8 of 25
Incident
number
Defect
number
Product /
Module Description
57833 97850 Draw
Title: PCD Internal Leaderline function has an incorrect icon. Symptoms: Incorrect icon displayed. Known workaround: None. Solution: Invalid icon has been changed to an appropriate alternative.
First released in Fix Version 1.1.0.18, Release No. 52301
Incident
number
Defect
number
Product /
Module Description
144190 Everything3D
Title: AVEVA E3D Insight 1.2.2 and AVEVA Mobile Applications Service 1.2.2 is not compatible with AVEVA Everything3D™ 1.1.0.17. Symptoms: AVEVA Mobile Applications Service 1.2.2 does not work together with AVEVA Everything3D™ 1.1.0.17. Known workaround: Do not upgrade to AVEVA Everything3D™ 1.1.0.17 on machines where AVEVA Mobile Applications Service is used. Solution: A compatible DLL is included in AVEVA Everything3D™ 1.1.0.18 allowing use of AVEVA E3D Insight 1.2.3.
57984 98391 Model
Title: Selection of nozzles not behaving correctly with more than one nozzle spec. Symptoms: Incorrect nozzle specification selection. Known workaround: Use one nozzle spec or set the spec in the attributes form (or command line). Solution: Fix to Nozzle form selection for multiple nozzle specifications.
61108 111098 Draw
Title: Autotagging of branches sometimes creates duplicate branch labels. Symptoms: When running Autotagging on a View using a tag type of 'Branches', certain branches with implied tubing result in two duplicate labels attached to the branch head. Known workaround: To delete duplicate label manually. Solution: The application was interpreting the implied tubing as requiring a second label on the same branch; this has now been corrected so that only a single label is generated.
65122 121518 Draw
Title: Remove CE doesn't work in Draw. Symptoms: Remove Element button does not correctly remove elements. Known workaround: Remove elements via canvas or command line action. Solution: Elements are removed from view by "Remove Element" button.
69775 139455 Draw
Title: Draw crashes when mouse is moved over existing drawing to create a dimension. Symptoms: Application crash. Known workaround: Issue is data dependant. Solution: Problem caused by redundant, copies of P-Points in CPS. Problem related to updating P-Point data when using object snaps. Bug Fixed.
70510 141586 Draw
Title: Visual Layers – Line Type and Colour lost on re-ordering. Symptoms: Observation that Visual Layers reorder alphabetically with last input Layer defaulting to Colour 1 and 8001 solid linestyle and the resultant reordered bottom Layer taking the attributes from the last created Layer. Known workaround: None. Solution: Layers are sorted on changing Layer selection rather than title editing.
Product Release Letter
d52326.doc 26/01/2015 Copyright 2015 AVEVA Solutions Limited Page 9 of 25
Incident
number
Defect
number
Product /
Module Description
54923 91842 Draw
Title: Overlay representation reference for Views. Symptoms: Any View created below the OVER does not inherit the Ruleset Reference; instead a new RRST is created for each and every View created. The new RRST is created within the referenced RPLB. The behaviour appears to copy the first available RRST in the RPLB including all owned RRULs. Known workaround: Can be corrected manually by user. Solution: CRSF, HRSF and RRSF attributes are now inherited from OVER when creating a new View. Bug fixed.
83237 Draw
Title: Text Editor - Buttons Ok & Cancel are not selected by Tab Symptoms: Cannot navigate using Tab key. Known workaround: Use mouse instead of using keyboard. Solution: Labels replaced with buttons to enable Tab action.
First released in Fix Version 1.1.0.17, Release No. 52294
Incident
number
Defect
number
Product /
Module Description
67266 133083 Piping
Title: automatic flange generation does not work for VTWA, FILT and PCOM. Symptoms: When you create the component with auto flanges selected - no flanges appear. Known workaround: Create flanges separately. Solution: The component editor form now does this automatically.
140121 Isodraft
Title: Isometrics fail to be shown with option Hyperplant on. Symptoms: Isometrics fail to be shown with option Hyperplant on. Known workaround: Switch Hyperplant off. Solution: Remove VNET code.
First released in Fix Version 1.1.0.16, Release No. 52284
Incident
number
Defect
number
Product /
Module Description
60184 105989 Draw
Title: PowerWheel Copy/Paste gives views and regions named differently from those created using Copy/Paste in the Explorer Symptoms: Copy views and regions created using the PowerWheel are sequentially numbered, not related to the originals. Solution: Draw has been modified so that in-canvas copy/paste of views and regions results in copies with names matching those created using the Explorer copy/paste.
67449 130111 Login
Title: Issues with E3D login form when using it on an NT authenticated Global Project Symptoms: User is locked out of password field in certain situations Solution: Modified some of the login specific for NT Authentication to ensure user is never locked out of password field.
69093 137496 Lexicon
Title: Query on DBREF object with UDA name greater than 13 characters can crash Symptoms: Query on a DBREF object (e.g. !!CE) with UDA name greater than 13 characters can crash the application Known workaround: use old PML syntax, e.g. var !a :ABC.. Solution: this has been corrected
Product Release Letter
d52326.doc 26/01/2015 Copyright 2015 AVEVA Solutions Limited Page 10 of 25
First released in Fix Version 1.1.0.15, Release No. 52267
Incident
number
Defect
number
Product /
Module Description
105221 Draw
Title: Import DWG/DXF with German characters. Symptoms: Imported German characters are wrong. Known workaround: No known workaround. Solution: German characters are imported correctly.
107525 Draw
Title: Dimensions - changing dimension line position via PG causes application crash. Symptoms: Application crashes. Known workaround: No known workaround Solution: Application does not crash in given case.
62484 113612 Draw
Title: Line types and text size is not exported correctly to DWF. Symptoms: Line types are thin instead of thick. Text size is not honoured. Known workaround: None. Solution: Line types are exported with correct weight. It looks fine if Line Weights are turned on in AutoCAD. Line types with glyph at one end/both ends/centre are not supported and will not be supported (DXF/DWG format limitation). Exported line types may look different than in Draw because of differences between PDMS and AutoCAD line types definitions. Hatches are not supported; some emulation can be added in the future. When line types with glyphs are used additional file (*.shx) with AutoCAD shapes definitions is exported.
62820 114375 Draw
Title: Incorrect refresh of User-Defined Linear and Fill Style Forms. Symptoms: Style area of the 'User-defined linear styles' or 'User-defined fill styles' form is populated by last form opened i.e. opening fill styles form followed later by linear styles will see fill styles within the linear form until a style table is clicked. Forms available from the respective Hatching and Style Library forms from the ADMIN tab on clicking the Select button. Known workaround: No known workaround. Solution: User-Defined Linear and Fill Style Forms display proper styles.
114924 Draw
Title: Auto preview button is missing while exporting to aveva.net. Symptoms: Auto preview button is missing for "“export to SVG/AVEVA.NET". Known workaround: No known workaround. Solution: Auto preview button is available.
65148, 67448
121588, 130107
Everything 3D
Title: Login form uses wrong Project data in Global project. Symptoms: Although Q PROJ returns the correct data (from /*GS), this is not displayed on the Login form. Instead values are taken from /*S. Known workaround: Use Q PROJ to verify project data. Project Number and Description should come from /*GS. Solution: All products with a Login form now show correct project details for Global projects.
64864 122393 Draw
Title: (Tools>Import CAD Drawing) - Import CAD Drawing no response. Symptoms: One could not import some CAD drawings. Draw stopped responding. Known workaround: No known workaround. Solution: There was an issue with generating commands for MTexts elements, which is fixed now.
65584 123296 Design
Title: Sub-equipment design template PTYP incorrect. Symptoms: PTYP of sub-equipment data element set to SBRE instead of SUBE. Known workaround: Reset value using Attributes form. Solution: PTYP for this type of data element now set to SUBE.
Product Release Letter
d52326.doc 26/01/2015 Copyright 2015 AVEVA Solutions Limited Page 11 of 25
Incident
number
Defect
number
Product /
Module Description
66180 125251 Draw
Title: Angular dimension texts are not correct in DXF/DWG export. Symptoms: The export DXF or DWG results with angular dimensions store for unknown reason the value of Õ at the end of the text dim. Known workaround: No known workaround. Solution: Angular dimensions are exported with proper text.
66761 127346 Draw
Title: Rescale with AutoCAD export is not working properly. Symptoms: The elements of type TEXP are not rescaled during AutoCAD export. Known workaround: No known workaround. Solution: TEXP elements are rescaled correctly during AutoCAD export.
128333 Everything 3D
Title: Application crashes on invoking Monitor module. Symptoms: When trying to enter the Monitor module, it crashes during load with a fatal error and forces it to close. Known workaround: Do not enter Monitor. Solution: Added validation to avoid the crash from happening.
67347 130152 Piping
Title: Isodraft crashes when detailing a Pipe connected to a Nozzle. Symptoms: Isodraft crashes with Database error 18. Known workaround: No known workaround. Solution: Do not attempt to read the Shop flag of a Nozzle.
First released in Fix Version 1.1.0.14, Release No. 52248:
Incident
number
Defect
number
Product /
Module Description
59081 102528 General
Title: Pasting of new values in the Collections result grid now works for non-sequential rows. Symptoms: Pasting of values in the Collections result grid only used to work for sequential rows. Known workaround: None. Solution: Program fixed.
119004 Spooler
Title: Element does not have attribute messages in Modify Spool Drawing Part Numbers form. Symptoms: Messages appear for each Pipe Fabrication attribute when selecting a Part. Known workaround: Ignore messages. Solution: Suppress messages.
64436 120971 Everything 3D
Title: Template Structural rules in E3D 1.1. Symptoms: Template repeat rules not working when using sections. Known workaround: Works at 12.1.SP4. Solution: Fixed for E3D1.1.14.
65126, 61635, 64619
124140, 90417,
110932, 121489
Draw
Title: Auto placement of labels was not working correctly. Symptoms: Autotagging labels were being placed far outside the view. Known workaround: none except manual labelling. Solution: Labels are now positioned correctly according to input from user for both remote and local intelligent label placement.
First released in Fix Version 1.1.0.13, Release No. 52243
Incident
number
Defect
number
Product /
Module Description
80996 Draw LDIM projection line clearance differs from DRAFT
Product Release Letter
d52326.doc 26/01/2015 Copyright 2015 AVEVA Solutions Limited Page 12 of 25
Incident
number
Defect
number
Product /
Module Description
112017 Draw Unable to set scale for the inserted OLAY from Property Grid
113139 Draw Issue with changing visual layers
116827 Draw Export to DXF/DWG - Font of exported text is lost after exploding in AutoCAD
65177 121708 Draw E3D Draw wrong View creation when Drawlist contains Panels owned by Equi
64771 120415 Piping Db Error 10 and SYSTEM crash when Query BRCOG (PSATTS) on Piping Component with ISPEC = unknown ref
119004 Spooler Error msgs displayed on clicking part numbers in display/modify SPLDRG window
First released in Fix Version 1.1.0.12, Release No. 52228
Incident
number
Defect
number
Product /
Module Description
60184 105989 Draw
Title: PowerWheel Copy/Paste gives views and regions named differently from those created using Copy/Paste in the Explorer Symptoms: Copy views and regions created using the PowerWheel are sequentially numbered, not related to the originals. Solution: Draw has been modified so that in-canvas copy/paste of views and regions results in copies with names matching those created using the Explorer copy/paste.
115687 Draw Title: AB ADP process drawings control sometimes gave misleading Error messages Symptoms: PML errors were reported Solution: AB ADP has been corrected to avoid the incorrect messages
62823 114379 Draw
Title: Button within ADMIN tab gives Error Symptoms: Clicking the Tag Ruleset button on the ADMIN tab gives the error: (44,33) FNF:File not found Solution: Error no longer occurs when creating a Tag ruleset from ADMIN ribbon tab
115172 Draw
Title: Draw sometimes fails to read shx font Symptoms: incorrect fonts on screen and particularly in export formats Solution: Draw now reads shx font files in 'read only' mode, which allows multiple instances to read the font at the same time
118120 General
Title: 'UNKNOW' element prevents hierarchy below from listing Symptoms: Elements below a CMTWLD in the MDB were not shown by early E3D versions Known workaround: If unknown top-level elements are last in the list, it is less important Solution: The system now handles UNKNOWN elements under the WORLD element better
64303 118363 Piping ERROR by select a piping component by using a user defined pipe bore
64328 118504 Piping Title: Piping Component Editor doesn't open the first time Symptoms: This occurred if there was no suitable item in the spec Solution: The PML handling the form has been amended
60461 106993 Spooler Title: Object SPLMTOCOMP fails if spec name contains "/" Symptoms: Error in Spooler MTO for a pipe with a spec name including a / Solution: Corrected
Product Release Letter
d52326.doc 26/01/2015 Copyright 2015 AVEVA Solutions Limited Page 13 of 25
Incident
number
Defect
number
Product /
Module Description
52067 86055 Structures Title: Problems with clash check and displaying obstruction for RAIL elements Symptoms: Rails behave differently from sections when obstructions are displayed Solution: Rail and kick plate elements are now handled for clashing handrails
119226 Preparation for Aveva insight 1.2
108165 GetShortPathName fails during variable init (evars)
First released in Fix Version 1.1.0.11, Release No. 52223
Incident
number
Defect
number
Product /
Module Description
53005 87502 Draw (Sections Planes) Section form now describes section type correctly
54569 90993 Draw (3D View > Direction) - Limits Box manipulation and View Direction
56717 95509 Draw (Sections Planes) Invisible Sections switched to visible
57520 97109 Draw (Labels) - TXTM Modification and removal of Drawing Labels improved
59495 103975 Draw (Export to ACAD) using Oblique-Glyph as Dim terminator causes blanking in ACAD
59435 103976 Draw (Export to ACAD) - Dim in Meter (E3D) are converted to mm in ACAD
60126 105991 Draw (DWG export of multiline dims) - all in one line in ACAD
108755 Draw (Export) - SYMBS no longer exported on layer 0 in DXF/DWG/DGN
108763 Draw (Export) - Missing OUTL Marker glyphs in DXF/DWG/DGN
112129 Draw 'Modify' option in dropdown menu of Section Planes form now OK for flat plane
61673 112163 Draw Moving a label to a hidden visual layer does not hide label text
113539 Draw Robustness improvements due to improved test procedures
115172 Draw
Title: Draw sometimes fails to read shx font Symptoms: incorrect fonts on screen and particularly in export formats Solution: Draw now reads shx font files in read only mode, which allows multiple instances to read the font at the same time
62458 113563 Model Crashes in MDB mode, when add/defer a database
108165 GetShortPathName fails during variable init (evars)
First released in Fix Version 1.1.0.8, Release No. 52206
Incident
number
Defect
number
Product /
Module Description
60523 107113 Cable Cable Status text for Status 8 now correctly shown as "Check Route”
57558 97182 Draw "AVEVA Line" group box can be resized, making it easier to assign user-defined line types to import
58902 102170 Draw Expressions now available for export to ACAD
59085 102537 Draw (Autotagging Admin) - Tagging Library form Tag options list now extends to SLH
60230 106152 Draw Rotate with copy no longer crashes E3D
84776 Draw An option 'Close All Tabs Except This' (current one) is now included
57511 97098 P-Line Visibility attribute is now in the Property Grid (View only). On change it updates the design according to configuration auto update desi settings.
98348 Draw PlotStyle - buttons malfunction
59540 104279 Draw Pipe Symbols are now correctly exported to DWG
59952 104986 108294
Draw (CAD export of labels) - All labels are now exported to the expected layer.
106999 Method edges() on path object is returning and extra line element for handrails
60587 107338 Model VOLM elements are now correctly handled when using ADD WITHIN
108165 GetShortPathName fails during variable init (evars)
85660 51867 SLH Initial Rise Stairs are not being modelled correctly
85684 Draw Common hotfixes - UI
85687 51878 SLH Some stair configurations incorrectly displayed as invalid
85692 Global Services Ensure that Global ScheduleManager form builds from the Global Database (not System db)
85697 Everything3D GDI Handles leak + USER Handles leak + Memory leak in Volume module cause Design (Model) DoS
85739 Integrator Error message is displayed on right clicking on Diagram Viewer when the Diagram is viewed through Integrator.
85760 Everything3D Error message is displayed on clicking current view icon under Settings group of 3DVIEW tab
85796 Model GDI Handles leak + USER Handles leak + Memory leak during adding same (existing in elements list) volume causes DoS
85821 Structures Panel Fitting Specification window is displayed when user tries to modify the Section fitting.
85842 Global Services DAC message fails to display when user tries to Transfer the design element using Global Scheduler.
85858 Integrator Status Controller Sub context menu settings are getting reflected in 3D Integrator MainTable when both are opened.
85863 Everything3D Status Control grid fails to display after deleting an element from Design Explorer which is added to the Collections form.
85864 Integrator Icon with picture fails to get displayed on adding the options from Context menu to Quick Access Toolbar.
86000 Global Services The Transfer work form takes more than 4 minutes to transfer any hierarchy when clicking on OK button
86002 52032 Everything3D Clicking the close button (red cross) on the Rotate form doesn’t clear aid.
86103 Paragon Collections - System Collections should not contain Drawlist or Current Selection
86116 52112 Draw Section Planes form - unable modify/create step section (explicitly or by snap)
86176 Integrator Element fails to display in 3D View drawlist once 'Integrator 3D View' drawlist is closed and reopened.
86198 52170 Draw Autotagging Layer Creation
86200 SLH Inclined kick plate is created when continuing the routing of the handrail created for Stair flight.
86202 Global Services CommunicationException error is displayed in event viewer on exiting the Design session.
86359 Piping Warning message displayed in Pipe editor form for a branch created below UDET pipe
86360 52300 Supports Grid is not available in Sample Data
86416 Everything3D 'Promote' ,'Demote','Edit Status' & 'Remove Status' disabled when multiple layouts are added in the Status Controller.
Product Release Letter
d52326.doc 26/01/2015 Copyright 2015 AVEVA Solutions Limited Page 21 of 25
Incident
number
Defect
number
Product /
Module Description
86448 Everything3D Clone view cannot be created after closing all 3D views
86480 Everything3D Tooltip fails to display for Minimize icon the Login form.
86500 Global Services Global Scheduler load error is displayed on trying to open Global Scheduler form when Change Primary Location command is in progress.
86505 Global Services Height of all rows gets changed on changing the height of single row in Transfer work form.
86507 Everything3D Holes Drawn option fails to work for elements in graphical opened using Empty View.
86511 52371 Piping Model Editor Flange Error
86519 Everything3D Application leads to crash when user tries to access the customized ribbon menu on the Quick Access Toolbar.
86579 Admin Error message box titles\captions are descriptive and should just state error
86580 Draw Add/Remove buttons for controlling the tasks, overlaps into 'Tasks Selected' area
86581 Admin List controls on the Database Configuration form are not centred (form appearance only)
86758 Everything3D Fatal error displayed when user Locks deleted element attribute form
86774 Draw InterpolationSearch code not protected from real values tolerance problems
86777 Piping Fitting Size undefined label displayed while routing the pipe.
86787 Draw DXF import adding cannot create new line style
86798 52561 Reporting Wrong field appearance
86808 SLH Graphical aid disappears on changing the parameters while creating the design template.
86823 Everything3D The user is unable to modify the status comment once the status has been changed in the status controller.
86825 SLH Landing link in Stair Summary pane is enabled before defining reference points while creating Stair flight in Detail mode.
86874 52616 Reporting Missing project information
86891 Everything3D Application crashes on setting incorrect URL in launch.init file
86892 Everything3D SGL errors displayed in command window on module switch
86905 Admin Propagate Link Documents option is selected even after clicking on No button in the confirmation window.
86910 Draw User unable to switch off Tool tips in Draw module.
86976 SLH Flip functionality fails to work, if user not update all the available Points drop down for the template profile.
Product Release Letter
d52326.doc 26/01/2015 Copyright 2015 AVEVA Solutions Limited Page 22 of 25
Incident
number
Defect
number
Product /
Module Description
86977 Cable An error message is displayed on clicking Create Cableway link in the Cableway Create Tasks form.
87036 Everything3D New init file processing does not cope with environment variables with foreign characters in environment variables
87038 Everything3D Search - The headers in the collections window disappear during Search
87072 Piping An error message is displayed on clicking UNDO button when Reselect tab is active in the Piping Component Editor form.
87128 Piping Component editor position through cursor should show planes on sloping or angled directions
87133 Draw An error message '(61,620) F&M: Value is invalid' is displayed on saving the Isometric ADP Defaults
87155 Admin Improper error message is displayed while trying to invoke application when the project is locked
87164 Everything3D Error message“(2,442) CALCULATOR ERROR” displayed on clicking Add button under Obstructions/Exclusions tab
87172 SLH Obstruction volume for stair flight elements are not displayed properly on adding these elements to 3D view by keeping the obstruction visibility ON.
87187 Everything3D User unable to navigate to ‘Clash’ and ‘obstruction’ Pipe Components after checking ‘Navigate to’ box in Clashes form.
87189 Draw Application Crashes with Fatal Error when user deletes the sheet while editing in 3D view.
87228 Model Aborted warning appears while selecting bubble view when scan locations are enabled
87244 Model Model Editor handle fails to disappear after deleting PIPE
87262 Draw Creation of MDS drawing results in empty ID list.
87264 52830 Piping Reselect Tag Does Not Get Repositioned
87285 Piping Datacon "check alignment geometry" text needs improving.
87293 Draw Fatal Error message displayed while switching the module when creating a general label.
87328 Integrator The Application hangs on building the Schematic element when the user performs the build operation after disabling the matching from the Integrator Report window.
87330 Piping An error message is displayed on clicking Undo button when Component Editor form is opened.
87335 Everything3D Fatal error message is displayed while switching the module when Clashes window is opened.
87343 52890 Piping Alternative Flange Option Error
87361 Everything3D Selecting branch for model editor/QPR on large bore pipes
87364 Everything3D Incorrect connection to laser server is possible
87368 Design Checker Error msg displayed on clicking Edit Rule Data button if the APPLDW /DesignChecker/Rules does not exist
87370 Design Checker Save to Excel option not working in the Edit Rule Data form
87372 52915 Piping Component Pointer Tag Error
87385 SLH Value is not displayed in selected imperial unit format for ‘TO Reference Point’ Elevation of a Stair Flight.
87399 52935 Piping LSTU Error
87401 SLH Design Aid Spheres for Stair Flight are oversized in the 3D view window while working with different Units settings.
Product Release Letter
d52326.doc 26/01/2015 Copyright 2015 AVEVA Solutions Limited Page 23 of 25
89829 Draw Plotting any SYTM on command line crashes
89877 SLH Function attribute value fails to set for the SLH Defaults.
89955 Everything3D Incomplete border around viewport icons
90049 54090 Everything3D Model Editor Set Increments has Dismiss, not Cancel button
Product Release Letter
d52326.doc 26/01/2015 Copyright 2015 AVEVA Solutions Limited Page 25 of 25
PRODUCT QUALITY STATEMENT
The development, maintenance and testing of AVEVA Solutions’ software products is carried out in accordance with the company’s KEYSTONE lifecycle processes and this document includes a summary of the testing carried out on this release and a list of significant defects known to exist at the time of release.
Development Testing
Developers have carried out unit testing of each enhancement and/or fix in the development environment to verify that any new functionalities have been correctly implemented and identified defects have been corrected. Regression tests have been run in the development environment to verify that enhancements and/or fixes have not adversely affected the integrity of the product.
System Testing
Limited independent system testing has been carried out on this product, as released, to verify that it installs correctly in all supported configurations, that any new functionalities have been correctly implemented and identified defects have been corrected.
Acceptance Testing
AVEVA’s Training and Product Support group is satisfied that the System Testing for this release is sufficient to assure product quality. Any exceptions found during Acceptance Testing or after release will be reported in the Product Release Latest Update Note on AVEVA's support web site http://downloads.aveva.com/52326/w52326.pdf .
Exceptions – Significant Defects and Recommended Workarounds
AVEVA intends to fix the defects listed below in a fix release or service pack as soon as reasonably possible.
Incident number
Defect number
Description Recommended
Workaround
56551 95209
There is an error in the Structural Design User Guide for SDNF Export/Import – Location of linear members in space. The record that is completely ignored is 4, as implied in the detailed description, and not 5.
Update documentation to version 1.1.0.2
For the latest list of exceptions and other updates, please see the Product Release Latest Update Note on AVEVA's support web site http://downloads.aveva.com/52326/w52326.pdf Please refer also to the Product Release Latest Update Note for the original full release, http://downloads.aveva.com/52072/w52072.pdf.