Top Banner
Product Guide Systems & Solutions Insulated Roof & Wall Panels / Daylighting / Fabrications Insulated Panel Systems Nordics
32

Product Guide Systems & Solutions - ks-kentico-prod-cdn ...

Jan 31, 2022

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Product Guide Systems & Solutions - ks-kentico-prod-cdn ...

1

Product Guide Systems & Solutions

Insulated Roof & Wall Panels / Daylighting / Fabrications

Insulated Panel Systems Nordics

Page 2: Product Guide Systems & Solutions - ks-kentico-prod-cdn ...

2

Contents

Introduction 3

Insulated Panels Range 4

Fabrications Range 5

Colour Range 6

System Benefits 7

Ease & Speed of Build 8

Fire Performance 9

QuadCore Technology 10

Wall & Ceiling PanelsArchitectural Wall Panel KS1000 AWP 12Wall & Ceiling Panel KS1000/1100/1200 NC/NF 14Wall & Ceiling Panel KS1150 TF/TL 16Wall Panel KS1000/1150/1200 FR 18Architectural Wall Panel KS600/750/900/1000 FH 20

Roof PanelsRoof Panel KS1000 RW 22Roof Panel KS1000 X-DEK 24Roof Panel KS1000 FF 26

Dayligthing SystemsRooflight KS1000 HTL 28Wall-Lite KS1000 WL 29

Fabrications 30

Our Services 31

Product Guide Contents

Page 3: Product Guide Systems & Solutions - ks-kentico-prod-cdn ...

3Product GuideIntroduction

About Kingspan„Together we have the opportunity to make our built environments more energy efficient, attractive,adaptable, environmentally sensitive and productive. The way we build can be more effective and reach higher standards than ever before. We can make our buildings really work for us; consuming and generating energy smartly to become real investments in our future”

These are Kingspan’s aspirations, and they shape every aspect of how the Group works.

We go beyond the simple manufacture and supply of high performance products, to provide our customers with solutions that take into account every aspect of the challenges they face. This bespoke, holistic approach has driven the success of our business until now, and made Kingspan the market-leading brand it is today. The Kingspan way includes exceptional service and support, grounded in unrivaled technical expertise, a strong commitment to environmental and social responsibility, investment in continuous research and development, and powerful and practical guarantees backing all products.

Our market-leading businesses epitomize the Group’s philosophy of customer-led, value-added solutions. Kingspan Group is the global leader in high performance insulation, building fabric and solar integrated building envelopes (see www.kingspan.com homepage). Founded in the late 1960s, the Group has grown steadily to become a prominent brand within the construction industry.

Global Presence

Today the Group has manufacturing plants around the globe, sells in more than 85 countries and employs more than 13,000 people worldwide.

Kingspan Insulated Panels, the biggest division of the five Kingspan’s divisions, is a global leader in the design, development and delivery of advanced building envelope products and solutions. It is widely recognized in the industry for the high quality and performance of its products as well as its commitment to excellent customer service and technical support.

Our product portfolio includes: Insulated Roof&Wall Panels; Fabrications, Safety & Lighting Solutions; Controlled Environments; Structural Products and BENCHMARK Facade & Roof Systems.

Our wide range of products allows developers, architects and contractors to meet and exceed today’s construction challenges and create functional buildings that are aesthetically pleasing, energy efficient, safe, cost effective and sustainable.

This product selector has been specifically designed for the Nordics markets and showcases Insulated Roof & Wall Panels in detail, with an overview on some other portfolios.

For further information on the other ranges, please refer to the www.kingspan.com country websites.

Gene M. Murtagh, Chief Executive Officer, Kingspan Group.

Manufacturing locations CEER

Page 4: Product Guide Systems & Solutions - ks-kentico-prod-cdn ...

4 Insulated Panels RangeProduct Guide

Wall & Ceiling Panels

Roof Panels

KS1000 AWPQuadCore / IPN

KS1000 RWQuadCore/IPN

KS600/750/900/1000 FHMineral Fiber

KS1000/1100/1200 NC/NFQuadCore / IPN

KS1000 FFMineral Fiber

KS1000/1150/1200 FRMineral Fiber

KS1150 TF/TLQuadCore / IPN

KS1000 X-DEKTM

IPN core

Fabrications

Insulated GuttersHighline Gutters

Safetraxx

Saferidge

Safety

Safepro2

Safeside

Kingspan Day-Lite Trapezoidal

Lighting

Kingspan Day-Lite Architectural

Top Hats

Preformed Corners

Flashings

Page 5: Product Guide Systems & Solutions - ks-kentico-prod-cdn ...

5

Fabrications, Safety& Lighting Solutions

Product GuideFabrications Range

Fabrications

Insulated GuttersHighline Gutters

Safetraxx

Saferidge

Safety

Safepro2

Safeside

Kingspan Day-Lite Trapezoidal

Lighting

Kingspan Day-Lite Architectural

Top Hats

Preformed Corners

Flashings

Page 6: Product Guide Systems & Solutions - ks-kentico-prod-cdn ...

6

Premium Metalic (PUR - 50 μm) – External

PolyesterStandard Colours (PES-50 μm )- External

Colour RangeInsulated Panels

RAL 9010White

White Aluminium

RAL 9010

RAL 7040

RAL 8004

RAL 9002

RAL 7012

RAL 3000

RAL 1015

RAL 7016

1. The printed colours are as accurate as possible but are for guidance purposes only. Please request a swatch sample from Kingspan to view accurate colour and texture.

2. If not indicated otherwise, the colors are available for all types of panels.* Colours RAL 3009 and RAL 7040 available for panels with modular width 1200 mm.* Colour RAL 7012 is available for KS1000 RW and KS1100 NC/NF.

RAL 7035

RAL 6020

RAL 9006

RAL 5010

RAL 9007

RAL 3009

Sechura

RAL 3009Oxidrot

GreyRockRAL 9002Grey White

Grey Aluminium

RAL 7016Onyx

DarkSkyRAL 9006White Aluminum

ArcadiaRAL 9007Grey Aluminum

Turmalin

Colour Range

Standard (PUR – 50 μm) – External

Kingspan SpectrumTM

Page 7: Product Guide Systems & Solutions - ks-kentico-prod-cdn ...

7

System Benefits

Product GuideSystem Benefits

Kingspan insulated panels are single component,factory pre-engineered systems.

Single ComponentAccelerated build speed canreduce time on site

The panels are made up of Kingspan’s unique QuadCore, IPN (Polyisocyanurate) or mineral fiber insulation core which is sandwiched between two layers of metal sheets – one the external weather side, the other a pre-finished internal liner. The result is a single component solution that replaces multi-part construction.

DurabilityLifetime performance

High Performance InsulationHigh U-values / FIREsafe / FIBREfree

Exterior Metal SkinPerfect weather barrier

Interior Metal SkinPerfect vapour barrier

Airtight SystemGuaranteed for the lifetimeof the building

Kingspan insulated roof and wall systems offer significant advantages over conventional site-assembled systems.They provide a fast, single-fix installation with high and durable thermal performance, insulation continuity, minimal air leakage and the elimination of interstitial cavity condensation and cold bridging.

Page 8: Product Guide Systems & Solutions - ks-kentico-prod-cdn ...

8

Unlike traditional multi-component systems, Kingspan insulated metal-faced panels are single-component systems, delivered by one company.

The systems can be quickly and easily installed with the aid of mechanical lifting equipment through a single-fix installation process. The rapid speed of installation can help to reduce the risk of accidents, as less time is spent working at height. It also means that the building is weathertight sooner, allowing internal fit-out and external finishing to commence earlier, minimising delays and the need for multiple trades, therefore achieving a significant reduction of overall build programme and cost.

Site-assembled, built-up systems are more likely to experience delays in construction due to the scheduling of multiple trades and the ordering of multiple components.

At the same time, guarantees, service support, site inspections and maintenance are also supplied by multiple sources which can lead to an increased risk of liabilities.

Ease & Speed of BuildInsulated Panels

Ease & Speed of Build

Site-assembled, Multi-component System

FIBREfree System

- Closed cellular structure of the insulation = zero moisture ingress;- no air infiltration; and- lifetime thermal reliability, without ageing or degradation.- No risk of toxic mould and bacteria growth.- No risk of building’s or employers liability insurance cover exclusion for presence of toxic mould.- No release of fugitive fibres into internal environments.

Insulated Panel, Single-component System

Built-up system Single-component

Page 9: Product Guide Systems & Solutions - ks-kentico-prod-cdn ...

9

Fire Performance

Product GuideFire Performance

NOT ALL INSULATION IS THE SAME

Fire resistance

The ability of buildings to perform well in the case of fire and to offer protection to both occupants and property are of primary importance to specifiers, owners, investors and insurers.

Kingspan Insulated Panels takes this issue extremely seriously and therefore all products have undergone extremely rigorous testing to ensure that they not only meet regulatory standards, but in most instances go far beyond.

Reaction to Fire Performance Kingspan Insurer Certified FIREsafe PIR core insulated panels can achieve high levels of reaction to fire performance in tests specified for regulatory purposes and large scale tests developed by the insurance industry.

In summary:

- Europe: EN 13501-1, particularly B-s1,d0. The ‘s1’ rating, being the best (lowest) smoke rating;- Global: FM 4880 – Class 1 Internal wall and ceiling panels without height restriction;- Global Insurance: FM 4881 – Class 1 External wall panel systems;- Global insurance: FM 4471 – Class 1 Roof panel systems;- UK Insurance: LPCB certified to LPS 1181 Grade EXT-A & B, for external roof and wall panel systems; USA / Global: NFPA 285 Façade testing;- Nordic countries – SP Fire 105 Façade testing.

Fire resistance of non-load bearing exterior walls is tested in accordance with European Norm EN 1364-1. The purpose of the test is to assess the material’s performance as a barrier to fire penetration through the sampled building material.

Kingspan insulated panels can achieve up to 60 minutes fire insulation and integrity according to EN 1364 standard! Contact our technical department for more information.

Page 10: Product Guide Systems & Solutions - ks-kentico-prod-cdn ...

10

It’s all in the grey cells

Unrivalled Thermal Efficiency

QuadCore TechnologyInsulated Panels

QuadCore Technology is Kingspan’s next generation of self-blended hybrid insulation core.Across the world of insulated panels, this innovationwith its distinctive grey microcells powers the industry’s highest combined performance:

• Unrivalled thermal efficiency• Superior fire protection• Enhanced environmental credentials• Longest performance guarantee

QuadCore Technology, together with our end-to-end services and whole building design know-how, takes Kingspan buildings to a higher level of lifetime performance, and delivers the ultimate protection for our partners, their buildings, and the environment for future generations.

Lifetime performance and value benefits

1. The class-leading aged lambda value of 0.018 W/m.K has the potential to reduce HVAC size, and lower both energy consumption and carbon emissions.

2. QuadCore Technology is a more streamlined solution relative to other insulation materials with associated benefits in interior space optimisation, transport, less amount of needed flashings and ease of handling during construction.

QuadCore Technology is certified as the most thermally efficient closed cell insulation core on the market.

Reference PointPolyurethane 0.023 W/m.K1

30%MORE THERMAL TRANSFER1

EPS0.030 W/m.K (0.030-0.038)2

22%LESS THERMAL TRANSFER1

Kingspan QuadCore Panels0.018 W/m.K

13%LESS THERMAL TRANSFER1

Kingspan PIR Panels0.020 W/m.K

34%MORE THERMAL TRANSFER1

Glass Fibre0.031 W/m.K (0.031-0.044)2

47%MORE THERMAL TRANSFER1

Rock Mineral Fibre0.034 W/m.K (0.034-0.042)2

Notes:1) Thermal Transfer for each insulant is based on the best quoted lambda value compa red to rigid polyurethane insulation with a typical lambda value of 0.023 W/m.K.2) The thermal conductivity range is based on data from insulation manufacturers websi tes or Agrement certificates. 3) Thermal conductivity (Lambda) W/m.K values quoted at 10°C.

Page 11: Product Guide Systems & Solutions - ks-kentico-prod-cdn ...

11

Superior Fire Protection

The improved thermal performance of QuadCore Technology helps optimise resource efficiency. It is also 100% recyclable and is CFC, HCFC, HFC free and has a very low Global Warming potential.

Lifetime Performance and Value Benefits

Complete QuadCore roof, wall or façade systems - where Kingspan has supplied the panel and all system ancillaries - have the additional security of a single- source system warranty from Kingspan.

• QuadCore Technology, together with whole building design support from Kingspan’s technical team, can help optimise performance in “green building” ratings systems. • The improved resource efficiency delivers better transport utilisation which means less truck movements to site.

The hybrid nature of QuadCore Technology delivers a range of unique improvements in fire performance.

Lifetime performance and value benefits

• With class leading reaction to fire, QuadCore™ adds vital minutes to escape times should the worst happen.

• QuadCore Technology also delivers improved fire resistance ratings leading to more cost-effective installations due to economies in steelwork and fixing, also improved spans, in certain applications.

Images shown are from an EN11925-3 comparative test using a roofer’s torch fire source.

Non-insurer approved PIR QuadCore Technology

Enhanced EnvironmentalCredentials

40 year thermal and structural panel guarantee

Product GuideQuadCore Technology

Page 12: Product Guide Systems & Solutions - ks-kentico-prod-cdn ...

12

Technical data

Application

KS1000 AWP is a concealed fixed wall system which can be laid verically or horizontaly and is suitable for wall cladding on all buildings except where there are low internal temperature conditions below (0oC). The application of panel should be verified for each project individually, in order to meet the design requirements.

Cross section module width 1000 mm

D

D

module module

Joint detail

KS1000 AWPArchitectural Wall Panel / QuadCore or IPN core / secret fix

KS1000 AWPArchitectural Wall System

Prod

uct

Mod

ule

[mm

]

Insulationcore

thicknessD

[mm]

Weight[kg/m2]

Panellengths

[m]Number

ofpanels

inbundle[pcs]

Heat transferU [W/(m2K)]

forIPN

λ = 0,022[W/mK]

at temp. 10°C

forQuadCore

λ = 0,018[W/mK]

at temp. 10°C

Fire parameters

KS10

00 A

WP

1000

Thic

knes

s of

stee

l fac

ings

ext.

/int

. 0,

6 m

m /

0,4

mm

Min

.(1)

Max

.

Reac

tion

Fire

resi

stan

ce

50 10,77 3,1

15,0

22 0,44

B-s1, d0

-60 11,17 3,0 18 0,37

80 11,97 2,9 13 0,28

EI 15

100 12,77 2,7 11 0,22

120 13,57 2,5 9 0,19

150 14,77 2,5 7 0,15

-

-

0,23

0,18

0,15

0,12

Note:1) At the request of the ordering party (for an additional fee) it is possible to deliver shorter panels. In other cases, short sections are combined in length meeting the production requirements.

2) Insulation core thickness available in Finland. Other available form other production in CEE.

170 15,57 2,5 6 0,130,11

(2)

(2)

(2)

Page 13: Product Guide Systems & Solutions - ks-kentico-prod-cdn ...

13

Technical dataProfilations Geometry - dimensions in [mm] Exterior Interior

M (micro)

E (euro)

W (wave)

I (minibox)

B (box)

P (plank)

D(deep)

standard on request Production in Finland

Material• Exterior/Interior facings - hot-dip zinc coated steel with a total of 275 g/m2 of zinc, according to EN 14 509; - austenitic stainless steel type 1.4301 according to EN 10 088;• Insulation core - QuadCore or FireSafe IPN closed-cell foam;

Exterior coating options• Polyester - for the environment category up to C3;• PVDF - for the environment category up to C4;• Plastizol (PVC) - for the environment category up to C4;• Spectrum (PU) - for the environment category up to C5;

Interior coating options• Polyester - for the environment category up to C2; • PVDF - for the environment category up to C4; • Foodsafe (PVC) - for the environment category up to C4;• Spectrum (PU) - for the environment category up to C5;

Reference documentsKS1000 AWP sandwich panels are manufactured in accordance with the EN 14 509 and CE marked. They meet the stringentquality control requirements, meet ISO 9001:2015 standards and guarantee long service life and reliability.

33,3±0,5 33,3±0,51±0,

3

1,2±

036±0,5

1,2±

03

6±0,5

200±0,5

10 10 20±0,5

0,8

±0,3

50±0,5 50±0,52,

5±0,

7

50±0,5 50±0,5

1,5±

0,4

Architectural Wall SystemKS1000 AWP

22±0,5 22±0,52±0,

3

3±0,3

0,7±

0,2

50±0,5 50±0,510±0,5

Page 14: Product Guide Systems & Solutions - ks-kentico-prod-cdn ...

14

Note:1) At the request of the ordering party (for an additional fee) it is possible to deliver shorter panels. In other cases, short sections are combined in length meeting the production requirements.

KS1000/1100/1200 NC/NFWall & Ceiling System

KS1000/1100/1200 NC/NFWall & Ceiling Panels / QuadCore or IPN core / through fix

Cross section

module width - 1000/1100/1200 mm

D

Application

NC/NF wall panels are supplied as standard without sealing tapes in the lock. Designed for applications where sealant or tape is to be applied to the lock.

The application of panel should be verified for each projectindividually, in order to meet the design requirements.

D

module module

Joint detail NC

Dsealing tape (waterproof)

sealing tape (airtightness)

module module

Joint detail NF

Technical data

Prod

uct

Mod

ule

[mm

]

Insulationcore

thicknessD

[mm]

Weight[kg/m2]

Panellengths

[m]Number

ofpanels

inbundle[pcs]

Fire parameters

KS10

00/1

100/

1200

NC/

NF

1000

/110

0/12

00

Thic

knes

s of

stee

l fac

ings

ext.

/int

. 0,

5 m

m /

0,5

mm

Min

.(1)

Mak

s.

Reac

tion

Fire

resi

stan

ce

100 12,39 1,85

14,5

11 0,22B-s1, d0

EI 15

120 13,17

1,8

9 0,18 EI 30

150 14,34

12,5

7 0,15

170 15,12 6 0,13

200 16,29 5 0,11

0,18

0,15

0,12

0,11

0,09

λ = 0,022[W/mK]

at temp. 10°C

forQuadCore

forIPN

λ = 0,018[W/mK]

at temp. 10°C

Heat transferU [W/(m2K)]

80

50 10,49

11,69

2,0

21

13 0,22

0,44

0,28

Page 15: Product Guide Systems & Solutions - ks-kentico-prod-cdn ...

15Wall & Ceiling SystemKS1000/1100/1200 NC/NF

Technical dataProfilations Geometry - dimensions in [mm] Exterior Interior

M (micro)

Q (minibox)

E (euro)

W (wave)

D (deep)

B (box)

P (plank)

standard on request Production in Finland

Material• Exterior/Interior facings: - hot-dip zinc coated steel with a total of 275 g/m2 of zinc, according to EN 14 509; - austenitic stainless steel type 1.4301 according to EN 10 088;• Insulation core - QuadCore or FireSafe IPN closed-cell foam;

Exterior Coating Options• Polyester - for the environment category up to C3;• INOX - for the environment category up to C5• Spectrum (PU) - for the environment category up to C5;

Interior Coating Options• Polyester - for the environment category up to C2; • Foodsafe (PVC) - for the environment category up to C4;• INOX - for the environment category up to C5• Spectrum (PU) - for the environment category up to C5;

Reference documents

NC/NF sandwich panels are manufactured in accordance with the EN 14 509 and CE marked. They meet the stringentquality control requirements, meet ISO 9001:2015 standards and guarantee long service life and reliability.

25 ±0,5

1±0,

3

25 ±0,5

22±0,5 22±0,52±0,

3

3±0,3

10 10 20±0,5

0,8

±0,3

50±0,5 50±0,5

2,5±

0,7

50±0,5 50±0,5

1,5±

0,4

0,7±

0,2

50±0,5 50±0,510±0,5

1,2±

03

6±0,5

1,2±

03

6±0,5

200±0,5

Page 16: Product Guide Systems & Solutions - ks-kentico-prod-cdn ...

16 KS1150 TF/TLWall & Ceiling System

KS1150 TF/TLWall & Ceiling Panels / QuadCore or IPN core / through fix

Technical data

Cross section

D

module module

Joint detail TF

Note:1) At the request of the ordering party (for an additional fee) it is possible to deliver shorter panels. In other cases, short sections are combined in length meeting the production requirements.2) Fire resistance parameter applies to sandwich panels in claddings of galvanized steel sheet.3) Fire resistance parameter for panels with Lorient Acrylic Sealant fire seal applied from the exterior of the joint.4) Parameter for panels with a joints stitched with screws every 200 mm

Application

The KS1150 TF/TL is a through fixed wall system which can be laid vertically or horizontally and is suitable for wall claddings on all types of buildings.

The application of panel should be verified for each project individually, in order to meet the design requirements.

D

modue width 1150 mm

Prod

uct

Mod

ule

[mm

]

Insulationcore

thicknessD

[mm]

Weight[kg/m2]

Panellengths

[m]Number

ofpanels

inbundle[pcs]

λ = 0,022[W/mK]

at temp. 10°C

forQuadCore

forIPN

λ = 0,018[W/mK]

at temp. 10°C

Fire parameters

KS11

50 T

F KS

1150

TL

1150

1150

Thic

knes

s of

stee

l fac

ings

ext.

/int

. 0,

5 m

m /

0,5

mm

Min

.(1)

Max

.

Reac

tion

Fire

resi

stan

ce40 10,09 2,8

15,0

16 0,59

B-s1, d0

-50 10,49 3,1 22 0,44

60 10,89 3,0 18 0,37EI 15(2)

80

100

120

150

170

180

200

11,69 2,9 13 0,27

-

-

-

0,23

0,18

0,15

0,12

0,11

0,10

0,09

0,22

0,18

0,15

0,13

0,12

0,11

EI 30(2)2,7

2,5 15,0 EI 45(2)(3)

12,49

13,29

14,49

15,29

15,69

16,49

11

9

7

6

6

5 EI 60(2)(3)(4)

Heat transferU [W/(m2K)]

D

module module

Joint detail TL

Page 17: Product Guide Systems & Solutions - ks-kentico-prod-cdn ...

17

Prod

uct

Mod

ule

[mm

]

Insulationcore

thicknessD

[mm]

Weight[kg/m2]

Panellengths

[m]Number

ofpanels

inbundle[pcs]

λ = 0,022[W/mK]

at temp. 10°C

forQuadCore

forIPN

λ = 0,018[W/mK]

at temp. 10°C

Fire parameters

KS11

50 T

F KS

1150

TL

1150

1150

Thic

knes

s of

stee

l fac

ings

ext.

/int

. 0,

5 m

m /

0,5

mm

Min

.(1)

Max

.

Reac

tion

Fire

resi

stan

ce

40 10,09 2,8

15,0

16 0,59

B-s1, d0

-50 10,49 3,1 22 0,44

60 10,89 3,0 18 0,37EI 15(2)

80

100

120

150

170

180

200

11,69 2,9 13 0,27

-

-

-

0,23

0,18

0,15

0,12

0,11

0,10

0,09

0,22

0,18

0,15

0,13

0,12

0,11

EI 30(2)2,7

2,5 15,0 EI 45(2)(3)

12,49

13,29

14,49

15,29

15,69

16,49

11

9

7

6

6

5 EI 60(2)(3)(4)

Heat transferU [W/(m2K)]

Wall & Ceiling SystemKS1150 TF/TL

Technical dataProfilations Geometry - dimensions in [mm] Exterior Interior

M (micro)

I (minibox)

D(deep)

F(flat)

standard on request

Material• Exterior/Interior facings - hot-dip zinc coated steel with a total of 275 g/m2 of zinc, according to EN 14 509; - austenitic stainless steel type 1.4301 according to EN 10 088;• Insulation core - QuadCore or FireSafe IPN closed-cell foam;

Exterior Coating Options• Polyester - for the environment category up to C3;• PVDF - for the environment category up to C4;• Plastizol (PVC) - for the environment category up to C4;• INOX - for the environment category up to C5• Spectrum (PU) - for the environment category up to C5;

Interior Coating Options• Polyester - for the environment category up to C2; • Foodsafe (PVC) - for the environment category up to C4;• PVDF - for the environment category up to C4;• INOX - for the environment category up to C5• Spectrum (PU) - for the environment category up to C5;

Reference documentsKS1150 TF/TL sandwich panels are manufactured in accordance with the EN 14 509 and CE marked.Kingspan provides insurer solutions tested in accordance with FM requirements.

QualityKingspan insulating sandwich panels are made from the highest quality materials, using the latest manufacturing technology, meet the stringent quality control requirements, meet ISO 9001:2015 standards and guarantee long service life and reliability.

Guarantees & WarrantiesThe Kingspan guarantees are individually assessed for each project, especially depending on the aggressiveness of the environment and the type of surface treatment chosen.

33,3±0,5 33,3±0,51±0,

3

10 10 20±0,5

0,8

±0,3

22±0,5 22±0,52±0,

33±0,3

Page 18: Product Guide Systems & Solutions - ks-kentico-prod-cdn ...

18 KS1000/1150/1200 FRWall System

KS1000/1150/1200 FRWall Panel / Mineral fiber core / through fix

Cross sectionmodule width 1000/1150/1200 mm

D

module moduleJoint detailApplication

The KS1000/1150/1200 FR is a through-fixed wall system which can be laid vertically or horizontally and it is suitable for wall cladding on all types of buildings except where there are internal low temperature conditions (below 0 °C). This through fix panel is also available for acoustic applications - KS1150 FA - please visit our webiste for more details.

Technical data

* Profilation S (segment) is recommended for the module 1000 mm. ** Profilation K (plank 600) is recommended for the module 1200 mm.

standard on request

Geometry - dimensions in [mm] Exterior Interior

M (micro)

E(euro)

I (minibox)

B (box)

P (plank)

S (segment)*

K (plank 600)**

F

50±0,5 50±0,5

1,5±

0,4

33,3 ±0,5 33,3±0,5

1±0,3

1,2±

03

6±0,5

1,2±

03

6±0,5

200±0,5

25±0,5

8±0,5

0,7 ±

0,2

308±525±0,5

10 10 20±0,5

0,8

±0,3

1,2±

03

6±0,5

600±5 600±5

0,7±

0,2

50±0,5 50±0,510±0,5

Page 19: Product Guide Systems & Solutions - ks-kentico-prod-cdn ...

19

Geometry - dimensions in [mm] Exterior Interior

M (micro)

E(euro)

I (minibox)

B (box)

P (plank)

S (segment)*

K (plank 600)**

F

50±0,5 50±0,5

1,5±

0,4

33,3 ±0,5 33,3±0,5

1±0,3

1,2±

03

6±0,5

1,2±

03

6±0,5

200±0,5

25±0,5

8±0,5

0,7 ±

0,2

308±525±0,5

10 10 20±0,5

0,8

±0,3

1,2±

03

6±0,5

600±5 600±5

0,7±

0,2

50±0,5 50±0,510±0,5

Wall SystemKS1000/1150/1200 FR

Prod

uct

Mod

ule

[mm

]

Insulation core

thicknessD

[mm]

Weight[kg/m2]

Panel lengths

[m]

Number of

panels in

bundle[pcs]

Heat transfer

coefficientU

[W/(m2K)]for

λ = 0,044*(th. 60-80 mm;

175-200 mm)for

λ = 0,043**(th. 100-150 mm)

[W/mK]at temp. 10°C

Sound reduction

index[dB]

Fire parameters

KS10

00/1

150/

1200

FR Th

ickn

ess

of

stee

l fac

ings

ex

t./i

nt.

0,6

mm

/ 0,

5 m

m

Min

.(1)

Max

.

R W R A1

R A2

Reac

tion

to

fire

Fire

resi

stan

ce

1000

/115

0/12

00 2

)

60 16,77

2,0

7,0 18 0,68*31 30 28

A2-s1, d0

EI 3080 19,17 9,0 14 0,52*

100 20,58

14,3

11 0,41**

32

31 29 EI 90120 22,78 9 0,35**

150 26,08 7 0,28** 32 29

EI 180175 30,57 6 0,25*31 29

200 33,57 5 0,22*

Note:1) At the request of the ordering party (for an additional fee) it is possible to deliver shorter panels. In other cases, short sections are combined in length meeting the production requirements.2) The above parametres are shown for modul 1150, please contact Kingspan technical department or visit our webiste for 1000 and 1200 mm.

Technical data

Material• Exterior/Interior facings - Hot-dip zinc coated steel with a total of 275 g/m2 of zinc, according to EN 14509• Insulation core - Insulation core made of Class A mineral wool;

Exterior coating options• Poliester - for the environment category up to C3;• PVDF - for the environment category up to C4;• Plastizol (PVC) - for the environment category up to C4;• Spectrum (PU) - for the environment category up to C5;

Interior coating options• Poliester - for the environment category up to C2; • Foodsafe (PVC) - for the environment category up to C4;• PVDF - for the environment category up to C4;• Spectrum (PU) - for the environment category up to C5;

Reference documents

FR and FA sandwich panels are manufactured in accordance with the EN 14 509 and CE marked. They meet the stringent quality control requirements, meet ISO 9001:2015 standards and guarantee long service life and reliability.

Page 20: Product Guide Systems & Solutions - ks-kentico-prod-cdn ...

20 KS600/750/900/1000 FH

KS600/750/900/1000 FHArchitectural Wall Panel / Mineral fiber core / through fix

Technical data

Application

The KS1000 FH is a concealed fi xed wall system which can be laid vertically or horizontally and is suitable for wall claddings on all types of buildings except where there are low internal temperature conditions (below 0 °C). The application of panel should be verified for each project individually, in order to meet the design requirements.

Cross section

modue width 600 mm 750 mm 900 mm 1000 mm

D

D

module moduleJoint detail

Technical dataGeometry - dimensions in [mm] Exterior Interior

M (micro)

E (euro)

I(minibox)

B(box)

P(plank)

S(segment)*

F

10 10 20±0,5

0,8

±0,3

33,3±0,5 33,3±0,51±0,

3

50±0,5 50±0,5

1,5±

0,4

1,2±

03

6±0,5

1,2±

03

6±0,5

200±0,5

25±0,5

8±0,5

0,7 ±

0,2

308±525±0,5

0,7±

0,2

50±0,5 50±0,510±0,5

* Profilation S (segment) is recommended for the module 1000 mm.

standard on request

Architectural Wall System

Page 21: Product Guide Systems & Solutions - ks-kentico-prod-cdn ...

21

Technical dataGeometry - dimensions in [mm] Exterior Interior

M (micro)

E (euro)

I(minibox)

B(box)

P(plank)

S(segment)*

F

10 10 20±0,5

0,8

±0,3

33,3±0,5 33,3±0,51±0,

3

50±0,5 50±0,5

1,5±

0,4

1,2±

03

6±0,5

1,2±

03

6±0,5

200±0,5

25±0,5

8±0,5

0,7 ±

0,2

308±525±0,5

0,7±

0,2

50±0,5 50±0,510±0,5

KS600/750/900/1000 FH

Prod

uct

Mod

ule

[mm

]

Insulationcore

thicknessD

[mm]

Weight[kg/m2]

Panellengths

[m]

Numberof

panelsin

bundle[pcs]

Heattransfer

coefficient U

[W/(m2K)]

forλ = 0,044*

(gr. 60-80 mm; 175-200 mm)

forλ = 0,043**

(gr. 100-150 mm)[W/mK]

at temp. 10°C

Soundreduction

index[dB]

Fire parameters

KS60

0/75

0/90

0/10

00 F

H

Thic

knes

s of

stee

l fac

ings

ext.

/int

. 0,

6 / 0

,5 m

m

Min

.(1)

Max

.

R W R A1

R A2

Reac

tion

to fi

re

Fire

resi

stan

ce

600/

750/

900/

1000

2)

60 17,23

2,0

7,0 18 0,70*31

29 28

A2-s1, d0

-80 19,63 9,0 14 0,53* 30 28

100 21,04

14,3

11 0,42**

32

32 28

int. EI 60ext. EI 120

120 23,24 9 0,35** 30 28

150 26,54 7 0,28** 31 27

175 31,03 6 0,25* 29 27

200 34,03 5 0,22* 29 27

Note:1) At the request of the ordering party (for an additional fee) it is possible to deliver shorter panels. In other cases, short sections are combined in length meeting the production requirements.

2) The above parametres are shown for modul 1000 mm, please contact Kingspan technical department or visit our webiste to get details for other modules.

Technical data

Architectural Wall System

Material

• Exterior/Interior facings - Hot-dip zinc coated steel with a total of 275 g/m2 of zinc, according to EN 14509; - austenitic stainless steel type 1.4301 according to EN 10 088;• Insulation core - Insulation core made of Class A mineral wool;

Exterior coating options

• Polyester - for the environment category up to C3;• PVDF - for the environment category up to C4;• Plastizol (PVC) - for the environment category up to C4;• Spectrum (PU) - for the environment category up to C5;

Interior coating options

• Polyester - for the environment category up to C2; • PVDF - for the environment category up to C4; • Foodsafe (PVC) - for the environment category up to C4;• Spectrum (PU) - for the environment category up to C5;

Reference documents

FH sandwich panels are manufactured in accordance with the EN 14 509 and CE marked. They meet the stringent quality control requirements, meet ISO 9001:2015 standards and guarantee long service life and reliability.

Page 22: Product Guide Systems & Solutions - ks-kentico-prod-cdn ...

22 KS1000 RWRoof System

KS1000 RWRoof Panel / QuadCore or IPN core / through fix

Technical data

Application

The KS1000 RW is a trapezoidal formed roof system with a standard fastening method (through fixed), which is suitable for all building applications, with a roof slope:• more than 4° (7%) for roofs with one panel in the

slope direction;• more than 8° (14%) for roofs with end lapping (two or

more panels in slope direction).The KS1000 RW panel can also be used for wall cladding. The application of panel should be verified for each project individually, in order to meet the design requirements.

Cross section

D d

module width 1000 mm

Note:1) At the request of the ordering party (for an additional fee) it is possible to deliver shorter panels. In other cases, short sections are combined in length meeting the production requirements.2) All panels are manufactured with factory made endlaps (inluded in total length). Dimension of cutback: 50-350 mm; 50-630 mm; Cut Back orientation: left or right.3) Fire resistance REI 30; RE 60 only when Promaseal XT sealant is used.

d

module moduleJoint detail

Prod

uct

Mod

ule

[mm

]

Insulationcore

thicknessd/D

[mm]

Weight[kg/m2]

Panellengths(2)

[m]Number

ofpanels

inbundle[pcs]

λ = 0,022 [W/mK]

at temp. 10°C

Fire parameters

RW

1000

Thic

knes

s of

stee

l fac

ings

ext.

/int

. 0,

5 m

m /

0,4

mm

Min

.(1)

Max

.

Fire

resi

stan

ce40/75 9,63

3,0 15,0

18 0,50

BROOF(t1,t2,t3)

B-s1,d0

-

60/95 10,43 14 0,34

REI 20; RE 3080/115 11,23 10 0,26

100/135 12,03 9 0,21

REI 30; RE 60(3)

120/155 12,83 8 0,18

160/195 14,43 6 0,13

forQuadCore

forIPN

λ = 0,018 [W/mK]

at temp. 10°C

-

-

0,22

0,18

0,15

0,11

Heat transferU [W/(m2K)]

200/235 16,03 5 0,110,09

Page 23: Product Guide Systems & Solutions - ks-kentico-prod-cdn ...

23Roof SystemKS1000 RW

Technical data

Profilation Geometry - dimensions in [mm] Exterior Interior

T (trapez)

I (minbox)

B (box)

standard Production in Finland on request

Material• Exterior/Interior facings: - Hot-dip zinc coated steel with a total of 275 g/m2 of zinc, according to EN 14509; • Insulation core - QuadCore or FireSafe IPN closed-cell foam;

Exterior coating options• Polyester - for the environment category up to C3;• PVDF - for the environment category up to C4• Plastizol (PVC) - for the environment category up to C4;• Spectrum (PU) - for the environment category up to C5;

Interior coating options• Polyester - for the environment category up to C2; • PVDF - for the environment category up to C4;• Foodsafe (PVC) - for the environment category up to C4;• Spectrum (PU) - for the environment category up to C5;

Reference documents

KS1000 RW sandwich panels are manufactured in accordance with the EN 14 509 and CE marked. Kingspan providesinsurer solutions tested in accordance with FM requirements. They meet the stringent quality control requirements,meet ISO 9001:2015 standards and guarantee long service life and reliability.

33,3±0,5 33,3±0,51±0,

335

±1,0

30±0,5

3,5±

0,5

333,3±2 333,3±2

0,7±

0,2

50±0,5 50±0,510±0,5

Page 24: Product Guide Systems & Solutions - ks-kentico-prod-cdn ...

24 KS1000 X-dekTMRoof System

KS1000 X-dek (XD)Roof Panel / IPN core / through fix

Technical details

Cross section4)

D

d

module width 1000 mm

Prod

uct

Mod

ule

[mm

]

Insulationcore

thicknessd/D

[mm]

Weight[kg/m2]

Productionlength(2)

[m]

Numberof panelsin bundle

[pcs]

Heat transfercoefficient

U [W/(m2K)]

for λ = 0,020 [W/mK]

at temp. 10°C

Sound reductionindex[dB]

Fire parameters

KS10

00 X

-dek

TM 4)

1000

Bottomdeck

thickness

Min

.(1)

Max

.

R W R A1

R A2

Spre

adin

g fir

e ra

te

Reac

tion

e to

fire

Fire

resi

stan

ce(3

)

0,9

mm

1,1 m

m

80/188 20,66 22,94

3,0 15,0

8 0,22

26 25 22 BROOF(t1) B-s2,d0

REI 15

100/208 21,46 23,74 6 0,18

140/248 22,54 24,83 5 0,13 REI 30

Note:1) At the request of the ordering party (for an additional fee) it is possible to deliver shorter panels. In other cases, short sections are combined in length meeting the production requirements.2) All panels are manufactured with factory made endlaps (inluded in total length). Dimension of cutback: 50-630 mm; Cut Back orientation: left or right.3) For maximum allowed span, in case of fire reistance requirements, please contact Kingspan Technical Service.4) Parameters in the table are suitable for panels KS1000 X-dek TM, version XD (steel/steel). Please contact Kingspan technical department or visit our website for more information about X-dek XM, XG and XB options.

D

d

module module

Joint detailApplication

KS1000 X-dekTM panel is suitable for flat roofs in all buildings, especially flat roof applications with roof slope > 1 %, except where there are low tempereature internal conditions. KS1000 X-dekTM panels are suitable for “Green Roof” solutions. KS1000 X-dekTM panels can be used as “standard” panel and as a part of steel structure “structural” panel (restraining for the rafters).They are available in 4 options of extrnal finishing: steel sheet (XD), PVC waterproof membrane (XM), fiber glass (XG) and bitumen base layer (XB).

Page 25: Product Guide Systems & Solutions - ks-kentico-prod-cdn ...

25Roof SystemKS1000 X-dekTM

Technical data

Profilation Geometry - dimensions in [mm] Exterior Interior

I (minibox)

V (trapez)

standard on request

Material• Exterior coating facings:

- XD version - hot-dipped zinc coated steel according to EN 10326:2004. Grade S280GD + Z275 – thickness0,7 mm - galvanised steel with a 5 microns clear film conversion layer for bonding to. Available profiles on top sheet: MiniBox;- XB version - Bitumen impregnated glass fibre membrane (TR20) suitable for multi layer torch on systems;- XG version - glass tissue facing (TR27) suitable for mechanically fixed or fully adhered single ply PVC or EPDM membrane. - XM version a) reinforced PVC membrane th. 1,2 mm & width 1100 mm - for standard application, or b) reinforced PVC membrane th. 1,5mm & width 1050 mm - with FM Global Certificate;

• Interior coating facings: - hot dip zinc coated steel according to EN 10 346 of 0,9 mm or 1,1 mm gauge; • Insulation core: - closed cell rigid IPN foam;

Interior Coating Options• Polyester - suitable for corrosivity category up to C2; • PVDF - suitable for corrosivity category up to C4;• Spectrum (PU) - suitable for corrosivity category up to C5;

Conformity

For Technical Approval please contact your local Kinsgspan Office.Kingspan provides insurer solutions tested in accordance with FM requirements (KS1000 X-dekTM XD - thickness 80 and 100 mm).

Quality

Kingspan insulated sandwich panels are manufactured from the highest quality materials, using state of the art produc-tion equipment to rigorous quality standards, complying with ISO 9001:2015, ensuring long term reliability and service life.

Guarantees & Warranties

Kingspan will provide coating and product guarantees on a project by project basis.

333±2 40±0,5

108

333±245±0,5 40±0,5

33,3 ±0,5 33,3±0,5

1±0,3

Page 26: Product Guide Systems & Solutions - ks-kentico-prod-cdn ...

26 KS1000 FFRoof System

Technical details

Cross sectionmodule width 1 000 mm

250 mm250 mm250 mm250 mm

Dd

Prod

uct

Mod

ule

[mm

]

Insula-tioncore

thicknessd/D

[mm]

Weight[kg/m2]

Panellengths

[m]

Numberof

panelsin

bundle[pcs]

Heattransfer

coefficient U

[W/(m2K)]for

λ = 0,044*(th. 60-80

mm; 175-200 mm)

forλ = 0,043**(th. 100-150

mm)[W/mK]

at temp. 10°C

Soundreduction

index[dB]

Fire parameters

KS10

00 F

F

1000

Thic

knes

s of

stee

l fac

ings

ext.

/int

. 0,

6 m

m /

0,5

mm

Min

.(1)

Max

.

R W R A1

R A2

Reac

tion

to fi

re

Fire

resi

stan

ce

60/94 17,47

2,0 13,0

13 0,67*31

30 28

A2-s1, d0 BROOF(t1), (t2),

(t3)

-

80/114 19,87 11 0,52* 30 29REI 90

100/134 21,28 9 0,41** 32 31 29

120/154 23,48 7 0,34**33 32 30

REI 120150/184 26,78 6 0,28**

175/209 31,27 5 0,24*33 32 29

200/234 34,27 5 0,21*

Note:1) At the request of the ordering party (for an additional fee) it is possible to deliver shorter panels. In other cases, short sections are combined in length meeting the production requirements.

module module

Joint detailApplication

KS1000 FF is a trapezoidal formed roof system with a standard fastening method (through fixed) and a mineral fibre insulation core, which is applicable for all building applications, where the roof slope is:• more than 5° (8.5%) for roofs with one panel in the

slope direction,• More than 8 (14%) for roofs with end lapping (two or

more panels in slope direction).The KS1000 FF panel with high fire performance can also be used for wall claddings.The application of panel should be verified for each project individually, in order to meet the design requirements.

KS1000 FFRoof Panel / IPN core / through fix

Page 27: Product Guide Systems & Solutions - ks-kentico-prod-cdn ...

27Roof SystemKS1000 FF

Technical data

Profilations Geometry - dimensions in [mm] Exterior Interior

T (trapez)

34±1

22±1

0,8±

0,5

250±2 250±2

I (minibox)

B (box)

standard on request

Material• Exterior/Interior facings - hot-dip zinc coated steel with a total of 275 g/m2 of zinc, according to EN 14 509; • Insulation core - Insulation core made of Class A mineral wool;

Exterior coating options• Polyester - for the environment category up to C3;• PVDF - for the environment category up to C4;• Plastizol (PVC) - for the environment category up to C4;• Spectrum (PU) - for the environment category up to C5;

Interior coating options• Polyester - for the environment category up to C2; • PVDF - for the environment category up to C4; • Foodsafe (PVC) - for the environment category up to C4;• Spectrum (PU) - for the environment category up to C5;

Reference documents KS1000 FF sandwich panels are manufactured in accordance with the EN 14 509 and CE marked.

Quality

Kingspan insulating sandwich panels are made from the highest quality materials, using the latest manufacturing technology, meet the stringent quality control requirements, meet ISO 9001:2015 standards and guarantee long service life and reliability.

Guarantees & Warranties

The Kingspan guarantees are individually assessed for each project, especially depending on the aggressiveness of the environment and the type of surface treatment chosen.

33,3 ±0,5 33,3±0,5

1±0,3

50±0,5 50±0,510±0,5

0,7±

0,2

Page 28: Product Guide Systems & Solutions - ks-kentico-prod-cdn ...

28 Rooflight KS1000 HTLDaylighting

Rooflight KS1000 HTL

Excellent energy efficiency

Intelligent sustainability brings twice the benefits – for both the environment and your customers. We developed our Kingspan Rooflight panel system with this aim in mind. You can reduce your customers’ daytime energy requirement by 70% by optimising as little as 5% of the roof area with light panels.

• Fast and simple installation• Low dead weight with high resistance• High ROI, including as a result of the superb

energy efficiency• Compatible with the KS1000 RW and FF roof panel

Application

A KS1000 HTL – Hybrid Rooflight is a product with GRP top sheet and polycarbonate bottom sheet combination for buildings with Kingspan KS1000 RW and KS1000 FF roof panel where thermal insulation and designed surface are required.

Basic conditions of the installation:

• Slope of the roof minimum for RW = 5.7° (10 %); for FF = 8° (14 %)

• Standard overlap is 250 mm• Distance between supports must be determined from

the span tables calculation. Please, contact technical department Kingspan.

Dimensions

• The shape of the GRP top layer is same as the shape of KS1000 RW and KS1000 FF roof panel.

• Standard length: max. 6250 mm (total length)• Width: 1000 mm (polycarbonate)• Thickness: 32 mm for RW panels and 32 or 25 mm for

FF panels

KS1000 RW/HTL

KS1000 FF/HTL

D = d + 34 mm

250 mm 250 mm 250 mm

dD

1000 ± 3 mm

dD

D = d + 35 mm

1000 ± 3 mm

333,3 mm 333,3 mm

Page 29: Product Guide Systems & Solutions - ks-kentico-prod-cdn ...

29Wall-Lite KS1000 WL Daylighting

Wall-Lite KS1000 WL

Enjoy architectural freedom with natural light

The Kingspan Wall-Lite is a translucent wall panel that allows natural daylight into buildings, whilst maintaining thermal efficiency and aesthetic appearance. This can help to lower both energy bills and CO2 emissions, whilst allowing occupants to enjoy high levels of natural light.

• Very good thermal performance• Light transmission up to 55% to EN410• Up to 25 years life expectancy.• Factory manufactured: ensures excellent fit

with KS1000 AWP panel

Application

Wall light panel KS1000 WL is a product designed for any buildingswhere wall panels Kingspan KS1000 AWP are used. The panel is suitable for all types of buildingsexcept those with high air humidity and low inside temperature.

Construction details

• Modular width 1,000 mm• Thickness 38 mm• Weight: 4.7 kg / m2

• Length: max. 6,000 mm• Colour: clear (standard)• Aluminum distance profiles to compensate thickness

difference between panel KS1000 AWP and KS1000 WL• Exterior side is provided with UV filter.• Thermal performance U-value of 1.23 W / m2K• The maximum spacing of supports for WL panels

installed as a single band highlight is 6 m.• Spacing for WL panels installed in series is 3 m.

Dimensions

Clear Opal Blue Green

Purple Red Orange Yellow

IR Green IR Blue

Colour range

* Please note: the only Standard color is Clear. If you need other colors, please contact Kingspan first.

1000 mm38

mm

* Aluminium spacers to suit adjacent insulated panel thickness

Page 30: Product Guide Systems & Solutions - ks-kentico-prod-cdn ...

30 FabricationsComplete Envelope

Fabrications

Kingspan offers a comprehensive range of high performance and quality fabrication products. Extensive experience in fabrication techniques, combined with state of the art production equipment, enables us to produce eye-catching and unique architectural features. All our products are custom designed and fabricated for each project in various colours, module sizes and shapes.

Explore our fabrications…

We produce standard and bespoke flashings, top-hats, corner panels, insulated and highline gutters and many many other fabrications to complete building envelope.

Short lead times and combined insulated panel and fabrications delivery, minimize the number of loads to the construction site and.

…visit our website: www.kingspan.com

Complete Systems & Services

Page 31: Product Guide Systems & Solutions - ks-kentico-prod-cdn ...

31Systems & Services Complete Envelope

Our services

We focus on consistently offering the best service to our customers. We offer high levels of customer support, including technical services through to product training. Our teams are happy to help you with all aspects of your project. We know that sometimes projects do not go as planned. Even if new, unforeseen challenges present themselves, you can be sure that we will remain flexible and adaptable. For the best end result.

Customer Accounts

Teams of sales and customer service are represented in all locations, from frontline co-ordinators to detailers. Our experts are here to provide a fast and professional response to your enquiry. Each department sees an order right through from start to finish, including dealing with transportation and after-sales care.

Technical Support

We offer technical advice and support throughout the design and construction process. From the provision of project specific details through to the creation of project specific specifications, Kingspan Technical Services can help to ensure that your building performs and complies with building regulations.

Installer Training

Our Field Services Team offer specialist installation training and demonstration of the products and systems we offer. This extensive training provides a basic level of competency in installation of our standard roof and wall products, covering the installation procedure, from safe unloading and handling, to installation and completion.

Samples and Literature

A sample can make a big difference. With a physical sample, you can better visualize the possibilities and configurations available to you on your project.

You can request also for hard copy brochures. All digital versions, including product data sheets, CAD/BIM files, you will find on our websites.

Page 32: Product Guide Systems & Solutions - ks-kentico-prod-cdn ...

32

Poland: Kingspan Sp. z o.o.ul. Przemysłowa 2027-300, LipskoTel.: +48 48 378 31 [email protected]

Estonia:Kingspan OÜMustamäe tee 5510621 Tallinn, EestiTel (+372) [email protected]

Latvia:Kingspan LatviaKronvalda bulv. 3-1LV-1010 Riga, Latvia Tel:+371 28393 [email protected] www.kingspan.lv

Lithuania:UAB KingspanNeries kr. 16 LT-48402, KaunasTel: +370 37 451 883 [email protected]

09/2018

please contact your local sales representative or visit www.kingspan.com

Care has been taken to ensure that the contents of this publication are accurate,but Kingspan Limited and its subsidiary companies do not accept responsibility for errorsor for information that is found to be misleading. Suggestions for, or description of,the end use or application of products or methods of working are for information onlyand Kingspan Limited and its subsidiaries accept no liability in respect thereof.

Contact us

Denmark:Kingspan A/SMercurvej 12ADK - 9530 StøvringTel: +45 7021 [email protected]

Finland:Kingspan OyVapaalantie 2A, 11, 01650 Vantaa, SuomiTel.: +358 9 878 6080

Norway:Kingspan ASGrålumveien 125712 Grålum, NorgeTel.: +47 69 14 44 [email protected]

Sweden:Kingspan ABKråketorspagatan 10C431 53 Mölndal, SverigeTel. +46 (0)31 760 90 [email protected]

info@kingspan.¡