Top Banner
Welcome to Total Door Systems We value your time, which is why we have converted our comprehensive product guide into a “digital binder” that can be viewed with ease on your computer or your mobile smartphone. For your convenience, we have embedded direct-links into our index pages. This function allows you to click through with ease to sections of the product guide that matter the most to you. Please feel free to contact our Design Support Services Manager Brian Butler at (248) 623-6899 ext. 106 or [email protected] at any time to assist with your Total Door System needs. We look forward to working with you on your next project. Section 1: Configurations / Functions Section 2: Finishes & Options Section 3: Hardware Section 4: Performance Data Section 5: Specs & CADs: Pair Section 5: Specs & CADs: Double Egress Section 5: Specs & CADs: Elevator 1.00 2.00 3.00 4.00 5.00 5.00 5.00
119

Product Guide 6.1.2015

Jul 22, 2016

Download

Documents

Total Door

 
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Product Guide 6.1.2015

Welcome to Total Door SystemsWe value your time, which is why we have converted our comprehensive product guide into a “digital

binder” that can be viewed with ease on your computer or your mobile smartphone.

For your convenience, we have embedded direct-links into our index pages. This function allows you to

click through with ease to sections of the product guide that matter the most to you.

Please feel free to contact our Design Support Services Manager Brian Butler at (248) 623-6899

ext. 106 or [email protected] at any time to assist with your Total Door System needs.

We look forward to working with you on your next project.

Section 1: Configurations / Functions

Section 2: Finishes & Options

Section 3: Hardware

Section 4: Performance Data

Section 5: Specs & CADs: Pair

Section 5: Specs & CADs: Double Egress

Section 5: Specs & CADs: Elevator

1.00

2.00

3.00

4.00

5.00

5.00

5.00

Page 2: Product Guide 6.1.2015
Page 3: Product Guide 6.1.2015

Open the door to possibility

Page 4: Product Guide 6.1.2015

When you’re one of a kind, you tend to see possibility where

others see limitations. We lead the industry in innovation and

performance of the design and build of fully integrated door

systems throughout the world. We take pride in what we do,

and in honoring the vision of our customers with world-class

door systems that provide infinite design options.

Innovation.

Page 5: Product Guide 6.1.2015

Total Door Systems’ history goes back to the late 1950s,

when inventor Leon Yulkowski developed a revolutionary

lock that became the industry standard and is still used

today. That appreciation for building the extraordinary

led to the development of a complete opening-ready door

system that uses components engineered to work as a

unified whole.

TDS doors can be found in hospitals, schools, government

and office buildings, shopping centers, hotels and other

buildings around the world. Our patented door systems

have fewer moving parts, reduced maintenance costs,

simpler installation, unbeatable reliability, unmatched

security and lower costs.

We’ve even led the industry with our Waterford, Michigan-

based headquarters, cited as best-in-class by national

manufacturing associations. With 100 percent on-time

delivery, sustainable manufacturing processes and the best

efficiency and quality track record in the industry,

we guarantee our door systems with pride.

is our life blood[Innovation]

Page 6: Product Guide 6.1.2015

thrives on creativity and integrity.

We understand. Buildings don’t just happen. They start with

a vision, are meticulously planned and built with multiple

needs in mind. That’s why we provide full design support for

architects and designers at no charge, and customized details

and specifications for your project that ensure your project

maintains the integrity of your design.

What can we help you create?

[Innovation]

Page 7: Product Guide 6.1.2015

Welcome to Total Door SystemsAs a fellow architect, I would like to introduce you to who we are -- a global innovator, engineering

integrated door systems that accommodate nearly infinite options for veneers, decorative faces and finishes.

This comprehensive product guide provides all the information, details and specifications you’ll need to

provide your clients with custom door systems that are easy to install, last up to 5 million cycles and can

precisely match your design.

We value your time, and have dedicated design support staff to help you quickly identify and specify a

Total Door System for your project. Brian Butler, our design support services manager is available at

(248) 623-6899, ext. 106 or [email protected].

You can also find a wealth of information at our website at www.totaldoor.com.

We look forward to connecting with you soon.

Patricia YulkowskiChief Executive OfficerTotal Door Systems(248) [email protected]

For quick reference, the square in the upper right or left corner of each section’s pages have been color

coded and numbered in the following manner:

Section 1: Configurations / Functions Section 5: Specs & CADs: Pair

Section 2: Finishes & Options Section 5: Specs & CADs: Double Egress

Section 3: Hardware Section 5: Specs & CADs: Elevator

Section 4: Performance Data

1.00

2.00

3.00

4.00

5.00

5.00

5.00

Page 8: Product Guide 6.1.2015
Page 9: Product Guide 6.1.2015

Configurations / Functions

Section 1:

Page 10: Product Guide 6.1.2015
Page 11: Product Guide 6.1.2015

Configurations / Functions

Standard Doors Specifications 1.01

Configurations 1.02

Fire Labels & Maximum Sizes 1.03

Frames 1.04

Exit Devices 1.05

Lever Mechanisms and Trim 1.06

Grip Mechanisms 1.07

Closing Devices 1.08

Door Functions 1.09

Door Handing 1.11

1S E C T I O N

Page 12: Product Guide 6.1.2015
Page 13: Product Guide 6.1.2015

Section 1 - Configurations / Functions:

Standard Door Specifications

DOOR BODIES

Skins

• 20,18or16gaugegalvannealedsteel

Cores

• Solidpolystyrenefoamcontinuouslybondedtodoorskins.

Temperaturerisecoresavailable.

Stiles / Rails

• 16gaugeelectrogalvanizedsteelverticalstiles

• 5-1/2”18gaugeelectrogalvanizedsteeltopandbottomrails

Finishes

• Two-partpolyurethaneinanycolor

• Primepaint

• Variouswoodveneerspecies

• Architecturalfilm

• Architecturalmetal,aluminum,stainlesssteel,etc

• Otheravailableonrequest

HARDWARE

Hinge & Locking Channel

• TheTotalDoorSystemisequippedwithheavygaugehighsecuritycontinuous

steelhingeandlockingchannelwithatwo-partpolyurethanefinish.

• Seestandardcolorchart.

• Customcolorsavailableonrequest.

Trim & Locks

• TheTotalDoorSystemisavailablewithlevers,gripsandor/exitdevices.

1.01

Page 14: Product Guide 6.1.2015

Section 1 - Configurations / Functions:

Door System Configurations

PAIR 90˚/180˚ PAIR

DOUBLE EGRESS 90˚/180˚ DOUBLE EGRESS

SINGLE

1.02

Pair Hold Open 180˚

Double Egress Hold Open 90˚

Elevator Single LR Hold Open 180˚

Pair Hold Open 180˚/90˚

Double Egress Hold Open 90˚/180˚

Page 15: Product Guide 6.1.2015

Section 1 - Configurations / Functions:

Configurations: Fire Labels and Maximum Sizes

Non Label 20 Min B & C A T-Rise B T-Rise A

20 GAUGE Single 4’2-3/16”x10’ 4’2-3/16”x10’ 4’2-3/16”x9’ 4’x8’ >4’to4’2- N/A

3/16”x9’

PR & DE 8’4-3/8”x10’ 8’4-3/8”x10’ 8’4-3/8”x9’ 8’x8’ >8’to8’4- N/A 3/8”x9’

18 GAUGE Single 4’ x 9’ 4’ x 9’ 4’ x 9’ 4’ x 8’ 4’ x 9’ 4’ x 8’

PR & DE 8’ x 9’ 8’ x 9’ 8’ x 9’ 8’ x 8’ 8’ x 9’ 8’ x 8

16 GAUGE Single 4’x8’ 4’x8’ 4’x8’ 4’x8’ N/A N/A

PR & DE 8’x8’ 8’x8’ 8’x8’ 8’x8’ N/A N/A

Removable mullions are only available on non-label doors up to 10’

A Label = 3 Hours

B Label = 1-1/2 Hour

C Label = 3/4 Hour

1.03

Page 16: Product Guide 6.1.2015

Section 1 - Configurations / Functions:

Frames

Total Door Systems do not require any special frame preparation or reinforcement. They may be used with a plain cased opening – even in label conditions – or may be used with single or double rabbeted frames and masonry openings. In replacement situations, old hinge and strike cutouts need only to be filled in. This does not invalidate the frame label

Information on frame sources and recommendations are available directly from Total Door Systems.

FRAME TYPES & DIMENSIONS

1.04

Page 17: Product Guide 6.1.2015
Page 18: Product Guide 6.1.2015
Page 19: Product Guide 6.1.2015

Section 1 - Configurations / Functions:

Exit Devices

Total Door System manufactures the most simple, most durable and most design friendly exit device system in the industry. It requires no lubrication and has only two moving parts, including the exit bar.

• FireRatedupto3hours.• ADAcompliant.• Availableinallfunctionsincludingelectric.• Availablewithleversorpush-pullgrips.• Availablewithcylinderdoggingand/orelectricremotedogging.• Projectionofonly1-5/16”onstandardpanic• FlushPanicprojectionofonly5/8”whenclosedand1/8”whenopen.• Normallifeexpectancyof5millioncyclesversus500thousandrequiredbyBHMAand ANSIstandards.• FactoryinstalledasanintegralpartoftheTotalDoorsystem.• LimitedLifetimeWarranty.

Available Exit Devices and Trim

1.05

Dimensions

Standard Based 6-11/16” 1-5/16” on Door Width*

6-11/16” 6-11/16” 1-5/16”

If the doors are electric, the SP14 must be 9”Not a legal panic device

1-9/16” 6-11/16” 1-5/16”

Two Sizes Available – 4-3/8” 5/8” 1/8” Based on Door Width Closed Open

24” for widths of 2’5-1/16” and wider14” for widths of 1’7” thru 2’5”

Available Finishes

Satin Anodized AluminumDark Bronze Anodized

Custom inserts available to match

door finish

Satin Anodized AluminumDark Bronze Anodized

Satin Anodized Aluminum

Used to deflect hinge side impact to panic device

Satin Anodized AluminumDark Bronze Anodized

Black Anodized

Custom inserts available to match

door finish

BHMA No.

628710

628710

628

628710711

Fire Ratings

All

All

All

All

Device

P14STP Exit Device

SP14 Push Pad

SP13/ABUPanic Edge Protector

PF200 Flush Panic Exit Device

24” for widths of 2’4” and wider15” for width of 1’6 to 2’3-15/16”6-11/16” for width under 1’6” Custom size panics available on request to match existing installations

Page 20: Product Guide 6.1.2015

Section 1 - Configurations / Functions:

Lever Mechanisms and Trim

Dimensions BHMA No. Available Finishes Fire Rating

2-3/4” 5-3/16” 11/16” 11/16” 605 Bright Brass All 606 Satin Brass 629 Bright Stainless 630 Satin Stainless 710 Dark Bronze

2-1/2” 4-15/16” 1” 11/16” 605 Bright Brass All 606 Satin Brass 629 Bright Stainless 630 Satin Stainless 710 Dark Bronze 2-3/4” 5-1/8” 1” 11/16” 605 Bright Brass All 606 Satin Brass 629 Bright Stainless 630 Satin Stainless 710 Dark Bronze 2-5/8” 5-1/8” 1” 11/16” 605 Bright Brass All 606 Satin Brass 629 Bright Stainless 630 Satin Stainless 710 Dark Bronze

1/4” 1-3/16” 6-3/4” 605 Bright Brass All 606 Satin Brass 629 Bright Stainless 630 Satin Stainless 710 Dark Bronze

1/4” 7-5/8” 6-3/4” 605 Bright Brass All 606 Satin Brass 629 Bright Stainless 630 Satin Stainless 710 Dark Bronze

Total Door System’s lever locking mechanisms are an integral part of the assembly and are factory installed.

• Fireratedupto3hours.• ADACompliant.• Availableinallfunctionsincludingexitdevicesandelectricfunctions.• OperateswithanystandardB/C4cammortisecylinder.• Normallifeexpectancyof5millioncyclesversusonly1millionrequiredbyBHMA andANSIstandards.• FactoryinstalledasanintegralpartoftheTotalDoorsystem.• LockmechanismshaveaLimitedLifetimeWarranty.

Available Lever Mechanism Trim

1.06

Device

60 Lever

82 Lever

83 Lever

84 Lever

Q19 Escutcheon

E29 Escutcheon for Electric Access

Page 21: Product Guide 6.1.2015

Section 1 - Configurations / Functions:

Grip Mechanisms

Dimensions BHMA No. Available Finishes Fire Ratings

1-7/8” 1” 2-11/16” 5-3/4” 628 Satin Anodized Aluminum All1-5/8” clearance 710 Dark Bronze Anodized 28M Mirror Anodized

1-1/16” 1” 2-11/16” 5-3/4” 628 Satin Anodized Aluminum All1-1/32” clearance 710 Dark Bronze Anodized 28M Mirror Anodized

2-1/4” 1/2” 2-11/16” 5-3/4” 628 Satin Anodized Aluminum All1-5/8” clearance 710 Dark Bronze Anodized 28M Mirror Anodized

3/16” 1” 2-11/16” 5-3/4” 628 Satin Anodized Aluminum All 710 Dark Bronze Anodized

Total Door System Grip mechanisms and trim offer convenience, simplicity in design and resistance to extreme abuse and forced entry. Ideal where the design demands functional trim that compliments or blends with its surroundings or where the doors and hardware will be exposed to consistent wear and tear; schools for example.

• Fireratedupto3hours.• ADACompliant.• Availableinallfunctionsincludingexitdevicesandelectricfunctions.• Operateswithanystandardcammortisecylinder.• Noexternalfasteners;trimcan’tloosenorfalloff.• Normallifeexpectancyof5millioncyclesversusonly1millionrequiredbyBHMAand ANSIstandards.• FactoryinstalledasanintegralpartoftheTotalDoorsystem.• GripmechanismshavealimitedLifetimeWarranty.

Available Grip

1.07

Device

M32 Grip

M33 Grip

M35 Grip

M52 Push

Page 22: Product Guide 6.1.2015

Section 1 - Configurations / Functions:

Closing Devices

Comments

• Seetechdatasheets76A&76B

• Trackdoublesasaheadstop

• 1’6”minimumdoorbodywidth

• Trackmountedtowall

• 1’6”minimumdoorbodywidth

• Standardmount(pullside)90-140°

• TopJambmount(pushside)120°

• ParallelMount(pushside)100°, 140°or180°

• CUSH&CUSH-H(pushside) available parallel arm only, withamaximum110°

• PullsideN/AonDoubleEgress

• Closerbodymountedinpocket, arm on door

• 2’0”minimumdoorbodywidth

Total Door System offers closers to meet any swing application.

• FireRatedupto3hours.• ADAcompliant.• FactoryinstalledasanintegralpartoftheTotalDoorsystem.• LimitedLifetimeWarranty.

Available Closers

1.08

MaximumDegrees

135

135

180

180

Mounting Location

Concealed in door

Concealed in door

Door ortop jamb

Wall

BestApplication

Interior

Interior/pocket

interior/exterior

Interior/pocket

TDC 96

TDC 96P - pocket

TDC 5051

AFPKT - 180

Page 23: Product Guide 6.1.2015

Section 1 - Configurations / Functions:

Door Functions

Description

Door is operated from either side at all times.

Door is operated by inside trim device only. Outside trim is alwaysinoperative.Nocylinder.

Door is operated from either side except when outside locked by inside turn piece. Operation of inner lever unlocks both sides. Also unlocked by turn piece or emergency key outside.

Door is operated from either side, except when both sides are locked by inside turn piece. Door unlocked by turn piece inside or emergency key outside.

Door is operated from either side except when both sides are locked by inside turn piece.

Door is operated from either side except when outside is locked by turn piece inside or key outside. Inside trim is always operational.

Door is operated from either side except when outside is locked by key from outside. Inside trim is always operational.

Door is operated from either side except when outside is locked by key outside; key cannot be withdrawn in unlocked position. Inside trim is always operational.

1.09Title

Passage

Egress

Privacy (Lever)

Privacy (Push/Pull)

Patio

Entry (Apartment or Office Suite)

Classroom

Storeroom

Function

L01G01 LP01GP01LFP01GFP01

L01.5G01.5LP01.5GP01.5LFP01.5GFP01.5

L02

G02

L02PG02P

L04G04

L05G05LP05GP05LFP05GFP05

L07G07LP07GP07LFP07GFP07

NOTE: 1) L = Lever G = Grip P = Standard Panic FP = Flush Panic D = Dogging CD = Cylinder Dogging 2) Dogging function not permitted on label doors 3)Non-Firelabelpanicsaresuppliedwithdoggingifrequested 4) Panic exit devices are approved for use on all labeled Total Door Systems and are Life Safety Rated

Dogging

CD&DCD&DCDCD

CD&DCD&DCDCD

CD&DCD&DCDCD

CD&DCD&DCDCD

Page 24: Product Guide 6.1.2015

Section 1 - Configurations / Functions:

Door Functions

Description

Door is operated from either side except when outside is locked by key outside or key inside. Inside trim is always operational.

Door is operated from either side except when outside is locked by key outside or turn-piece inside. Operation of inside lever automatically unlocks outside.Dooralsounlocksbyturn-pieceorkey.(Notavailablewith grips)

Door is operated from either side except when locked by key from either side.

Door is operated from either side except when both sides are locked by key outside or turn-piece inside.

Door is operated from either side except when both sides are locked by key outside.

1.10Title Function

Apartment (Building Entry)

Dormitory or Convalescent

Store Door

Deadlock

Deadlock

Function

L09G09

L13

L14G14

L17G17

L18G18

NOTE: 1) L = Lever G = Grip P = Standard Panic FP = Flush Panic D = Dogging CD = Cylinder Dogging 2) Dogging function not permitted on label doors 3)Non-Firelabelpanicsaresuppliedwithdoggingifrequested 4) Panic exit devices are approved for use on all labeled Total Door Systems and are Life Safety Rated

Page 25: Product Guide 6.1.2015

Section 1 - Configurations / Functions:

Door Handing

Normallytheoutsideofadooristhesidefromwhichitmaybeopenedbyakey–orthe“keyside”.Thehardware, therefore, effects the hand of the door. To visualize this, examine the layout below of a possible door arrangement from a corridor to four separate offices. The corridor would be the outside because it is the key side.

If the door swings away from the viewer, the hand is a regular hand, i.e. left hand (LH) or right hand (RH).

CORRIDOR

If the door swings towards the viewer, the door is reverse swing, i.e. left hand reverse (LHR) or right hand reverse (RHR).

1.11

Office No. 1Right Hand(RH)

Office No. 3Right Hand Reverse(RHR)

Office No. 2Left Hand(LH)

Office No. 4Left Hand Reverse(LHR)

Page 26: Product Guide 6.1.2015
Page 27: Product Guide 6.1.2015

Finishes & Options

Section 2:

Page 28: Product Guide 6.1.2015
Page 29: Product Guide 6.1.2015

Finishes & Options

Finishes

Veneers 2.01

Architectural Films 2.02

Architectural Metals 2.03

Paint 2.04

Options

Lite Kits & Glazing 2.05

Gasketing – Sound, Weather & Smoke 2.07

Plates – Kick, Mop, Armor & Edge Guards 2.07

Removable Mullions 2.07

Labeled Psychiatric Hinge 2.07

Additional Door Models

Blast Doors 2.08

Lead Lined Doors 2.08

Electric Doors 2.08

Remotely Controlled Electrical Doors

Components, Definitions and Suggestions 2.08

2S E C T I O N

Page 30: Product Guide 6.1.2015
Page 31: Product Guide 6.1.2015

2.01Section 2 - Finishes & Options:

Veneers

Great design requires a full range of options. Our integrated door systems can accommodate nearly any

design face, veneer or architectural metal finishes. The only limitation is your imagination. What do you want to create today?

Our popular wood veneers offer design flexibility and beauty. And because we can customize our doors to

seamlessly blend with the rest of the room, we can ensure that the focus stays on your design.

Since wood is a natural material, the grain and color will vary. Total Door Systems cannot guarantee that

the actual product color or grain pattern will duplicate any of these examples. These examples simply

illustrate the basic color and grainfill of veneer and variations will occur from one finished product to

another. Samples must be submitted for approvals.

Do not use this page to make final color selections.

Cherry

Provincial

Colonial Maple

Natural

Red Oak

Dark Walnut

Golden Oak

Puritan Pine

Red Mahogany

Page 32: Product Guide 6.1.2015

Section 2 - Finishes & Options:

Architectural Film2.02

Total Door Systems uses architectural films that are durable and realistic. They are applied with a pressure

sensitive adhesive and air removal system backing for a smooth finish and beautiful presentation that

completes your design.

And because the films are produced using a next-generation, multi-layered printing and minute embossing

process, the final appearance is nearly identical to that of real wood, leather or metal, even when stretched

to cover corners and curves. Another benefit? The architectural films we use are solvent/chemical resistant,

anti-bacterial and anti-mold, colorfast, washable – even scrubbable, as they are abrasion-resistant.

Cherry

Antique Teak

Fine Cloth

Ebony

Walnut

Neo Cloth

Honduras Mahogany

Random Wave

Vintage Leather

Page 33: Product Guide 6.1.2015

Section 2 - Finishes & Options:

Architectural Metals 2.03

We believe design should be set free to inspire – not limited to a few manufacturer’s choices. Total Door

Systems offers a broad range of architectural metal finishes to complete your vision and create striking,

yet functional door systems. Beauty and durability in one integrated system. What do you want to create today?

Squares

3-ND

Random Swirl

60 LTH

Non-Directional

Sand Tex

1SLG

RTP

2-WL

Linen

5-WL

XTP

Page 34: Product Guide 6.1.2015

Section 2 - Finishes & Options:

Paint Colors2.04

Whether it’s prime paint or custom matched color, we take pride in our approach. Our custom colors are

created using a two-part catalyzed polyurethane, and our architectural colors are matched in our paint

kitchen then baked on for extreme durability. We offer Polane “T” for interior applications and Polane

“S” – which offers great UV protection – for exterior applications. (There is an additional cost for

metallic paint)

White Sand

Pure White

Black

DB (Dark Bronze)

Gray

Silver

Page 35: Product Guide 6.1.2015
Page 36: Product Guide 6.1.2015
Page 37: Product Guide 6.1.2015

Section 2 - Door System Options:

Lite Kits/Glazing 2.05

Alllitekitsaremadeof16gaugecoldrolledgalvannealedsteelwithT.I.G.weldedmiteredcorners.Finishisbaked-onpoly.Litesareavailableforallglassthicknessesupto1-1/8”.Liteframesprojectonly1/16”beyondthedoorskin.

Alllitekitsmaybeglazedwithfireratedceramicglazing,temperedglass,non-ratedlaminatedsafetyglassorimpactratedwireglass.

Note: TemperatureRiseLabels:100in2maximumforalllabels,12”maximumvisiblewidth,33”maximumvisibleheight.

Litekitcutoutis2”largerthanvisibleglasssize.

Doorsizemaylimitmaximumvisibleheightandwidth.

Note: TemperatureRiseLabels:100in2maximumforalllabels,10”maximumvisiblewidth,33”maximumvisibleheight.

Litekitcutoutis2”largerthanvisibleglasssize.

Doorsizemaylimitmaximumvisibleheightandwidth.

Max. in2 VisibleGlass

Label Max. Number ofLites

Max. Visible GlassWidths

Max. Visible GlassLengths

FIRELITE PLUS & NT

A (3 hr)

B (1-1/2 hr)

C (3/4 hr)

20 Minute

100”

2034”

3204”

3204”

NoLimit

NoLimit

NoLimit

NoLimit

12”

36”

36”

36”

33”

56”

89”

89”

Door TypeLabel Max. in2 VisibleGlass

Max. Visible GlassWidths

Max. Visible GlassLengths

SUPERLITE 1W

B (1-1/2 hr)

C (3/4 hr)

20 Minute

20 Minute

Steel

Steel

Steel

Steel

552”

2856”

3289”

3341”

12”

34”

36”

35”

46”

84”

92”

95”

SUPERLITE 1

Page 38: Product Guide 6.1.2015

Section 2 - Door System Options:

Lite Kit Options2.06

Note: Any lite size outside of the parameters in the above examples, will be considered M Lite, top or MM Lite, top & bottom.

FG Lite G Lite GG Lite N Lite

N1 Lite NN Lite V Lite

Page 39: Product Guide 6.1.2015

Section 2 - Door System Options:

Miscellaneous Options 2.07

Gasketing – Weather, Smoke and Sound

• AllGasketingisU.L.approvedforfiredoorsandisidenticalwhetherusedforsound,weatheror smoke control purposes. Gasketing is included in all door orders.

• Headgasketingisshippedlooseandmustbefieldapplied.Lockingchannelgasketingonpairs, factory installed.

See page 4.02 for STC and R ratings

Plates, Kick, Mop, Stretcher, Armor and Hospital Edge Guards

• Alloftheaboveplatesandedgeguardsarebondedtothedoorfaceandwrappedaroundthedoor edge to provide a mechanical interlock to the door edge. Kick, mop, and stretcher plates use no screws or other visible fasteners.

• Edgeguardsarerivetedinthefactory.Installationisincludedinthepublishedprice.

• Standardfinishis630.Finishsurfacesareprotectedbyaheavygaugeadhesiveplasticfilm.IPC available and custom options.

• Standardheightskick-platesandmop-platesareavailableupto40”,fullheightoptionavailable.

Removable Mullion

• Useinhighsecurity–highabusearea–notfirerated,exteriordoorsforexample.

• Removablemullionsareonlyavailableonnon-labeldoorsupto8’.

Labeled Psychiatric Hinge

TOTAL DOOR SYSTEMS® labeled Psychiatric Hinge allows for quick removal of a door from the push side should the door become blocked from the pull side. This is accomplished by removing the screws from the Psychiatric Hinge backing plate.

• Sizerestriction:3’8”x8’0”• Handing: RightorLeft–StraightHandOnly

Page 40: Product Guide 6.1.2015

Section 2 - Door System Options:

Additional Door Models2.08

Blast Doors

Blast doors available from 144 to 180 PSF. Contact factory for more information.

Lead Lined Doors

Lead lined doors are available in either label or non-label.

The lead thickness may be specified only as either 1/32” or 1/16”. A 1/16” thickness is the maximum possible for TOTAL DOOR SYSTEMS® since it matches the radiation shielding capacity of the steel verticals.

Lead lined doors are offered in singles (1/32” or 1/16”) and pairs (1/32” only) and with standard delivery.

Nominal size of lead lined TOTAL DOOR SYSTEMS® should not exceed 28 square feet per leaf.

Available in all labels.

Testing of the doors generally done by the state after the installation has been completed.

Electric Doors

Remotely controlled electric doors are available as follows:

•Single,pairordoubleegress.•Non-labelorA,B,andClabelor20minutelabelinsteelonly.•Remoteunlatchingforusewithautomaticdooroperators.•Remoteunlocking–failsafeorfailsecure.•ElectricPanic

Remotely Controlled Electrical Doors

The following is an attempt to explain in layman’s terms the operation and function of the Openings electrically controlled TOTAL DOOR®.

I. Basic Components

A. Power transfer devices from the frame to the door.

This power transfer is accomplished by means of a 4 wire current transfer block which is concealed and inaccessible when the door is closed. This device is a part of the system provided by TOTAL DOOR SYSTEMS® and is installed and pre-wired at the factory. The 4 wire conductor carries power to the solenoid and, if desired, signals when the solenoid armature is fully seated, indicating that unlatching or locking/unlocking of the door has been completed.

B. Internal door wiring is by TOTAL DOOR SYSTEMS®.

C. Solenoid: The power surge solenoid is used in all electric TOTAL DOOR SYSTEMS®. Two very important features of this solenoid are:

1. The force exerted by the solenoid at the beginning of its stroke is approximately 200 ounces (12-1/2 lbs.). This force is approximately four times larger than necessary for operation.

2. After completing its work and when fully seated, the armature actuates a switch to transfer from a pulling force of 150 watts to a holding force of 12 watts. This switch accomplishes two things. It prevents excessive heat build-up in the door when under constant power and it permits the coil to signal the system that is has completed its work. For example, in automatic door operation, the automatic door cycle does not commence until the switch signals that unlatching has been completed.

D. Power Supply #100: A 24 volt D.C. 6 amp (120VA) power supply operating on 110 volts A.C. Power Supply #100 is available from TOTAL DOOR SYSTEMS® as a separate item.

Page 41: Product Guide 6.1.2015

Section 2 - Door System Options:

Additional Door Models 2.09

Remotely Controlled Electrical Doors

I. Basic Components (continued)

E. Design Limitations: Electric operation can be combined with levers and/or standard panics.

F. Control: All electric doors’ solenoids lock, unlock or unlatch, based upon being powered or not. Any device which closes or opens a switch will achieve the doors’ intended function. This device can be a keyed wall cylinder switch, a card reader, P.I.N. pad, a voice recognition system, fire alarm, time clock, motion detector, carpet, etc…

G. Label Approval: All of the above devices and combinations are listed as assemblies for A, B, C and 20 minute label TOTAL DOOR SYSTEMS®.

II. Definitions

A. Fail Secure: (E SEC) Power interruption, intentional or accidental, puts the mechanism into a locked mode. Use of the fail secure control must not violate local codes. One Model #100 power supply may handle two doors.

B. Fail Safe:(ESAF) Power interruption, intentional or accidental, puts the mechanism into an unlocked mode. One Model #100 power supply may handle two doors.

C. Remote Unlatching: (E UNL) Power to the solenoid unlatches the door as long as the power is on. Power off allows the door to revert to its previous mechanical mode. One Model #100 power supply may handle two doors.

D. Electric Panic: (E PAN) Power to the solenoid locks the panic as long as the power is on. Power off allows activation of the panic to unlatch the door.

III. Suggestions

A. Automatically Operated Doors: This operation requires use of our “Remote Unlatching” (E UNL). Example of operation: The floor mat, wall switch, or motion sensor sends power to the door solenoid: after unlatching is completed the operator is signaled by the door to open. Can be used with single, pair or double egress doors, any label and may be normally locked or just latched.

B. Stair Hall Doors: This application normally calls for electric fail safe operation (E SAF). Doors are normally electrically locked from the stair side and electrically unlocked when power is interrupted, by a smoke detector or fire alarm. The door may be left unlocked by means of a key cylinder of time clock and may be accessed momentarily by P.I.N. pad, card reader, key or other.

C. Security Rooms: This application normally calls for electric fail secure (E SEC). Doors are electrically unlocked. When power is interrupted doors may be locked one or both sides. Momentary access may be by key, P.I.N. pad, card reader or other. The door may be left unlocked by key or access system if desired.

D. Delayed Egress, Locking Panic System: Exit device is locked. Activating the panic will start an irreversible predetermined time delay once complete will allow egress through the door.

1. A request to exit switch can be installed in the panic device for request to exit or delayed egress functions.

E. Electric Panic: (E PAN) application is for psychiatric, detention facilities and delayed egress applications wherein the panic is locked by 24 volt D.C., 6.0 amp power source. Interruption of power unlocks the panic. One Model #100 power supply may handle two doors.

1. A request to exit switch can be installed in the panic device for request to exit or delayed egress functions.

Page 42: Product Guide 6.1.2015
Page 43: Product Guide 6.1.2015

Door System Hardware

Section 3:

Page 44: Product Guide 6.1.2015
Page 45: Product Guide 6.1.2015

Hardware

P14 / P14STP Exit Device 3.01

SP14 Push Pad 3.02

PF 200 Flush Exit Device 3.03

Lever 60 3.04

Lever 82 3.05

Lever 83 3.06

Lever 84 3.07

M32 3.08

M33 3.09

M35 3.10

M52 3.11

TDC 96/TDC 96P Concealed Closer 3.12

TDC 5051 Door Closer 3.13

AFPKT-180 Pocket Door Closer 3.14

TDH 100 Electromagnetic Holder 3.15

TDH 200 Electromagnetic Holder 3.16

Continuous Hinge 3.17

Continuous Locking Channel 3.18

3S E C T I O N

Page 46: Product Guide 6.1.2015
Page 47: Product Guide 6.1.2015

Section 3 - Hardware:

P14 / P14STP Exit Device

Exit Devices

• ADAcompliant• Fireratedupto3hours• Limitedlifetimewarranty• Availablewithlevers,operatinggripsorexitonly• Allelectricalfunctionsavailable• FactoryinstalledasanintegralpartoftheTotalDoorsystem• Cycletestedtoover5millioncyclesversus500thousandrequired byBHMAandANSIstandardsforexitdevices

3.01

SPECIFICATIONS

Lengths

Height

Projection

Centerline from bottom of door

Finishes

Dogging Options

•Standard24”–P14STP•Fulldoorwidth–P14(custom)

•6-11/16”

•1-5/16”

•39-9/16”StandardHeight•34-9/16”ElementaryHeight

•628SatinAnodizedAluminum•710DarkBronzeAnodized•Inserttomatchdoorbodyor custom finish•Architecturalmetalinserts: 629,630,707,667,710

•Mechanical•Electric–E-UNL

Page 48: Product Guide 6.1.2015

Section 3 - Hardware:

SP14 Push Pad

Lengths

Height

Projection

Centerline from bottom of door

Finishes

Dogging Options

•Lengths6-11/16”–standard•9”–electricfunctions

•6-11/16”

•1-5/16”

•39-9/16”StandardHeight•34-9/16”ElementaryHeight

•628SatinAnodizedAluminum•710DarkBronzeAnodized•Inserttomatchdoorbody or custom finish•Architecturalmetalinserts: 629,630,707,667,710

•Mechanical•Electric–E-UNL

Push Pad

• ADAcompliant• Fireratedupto3hours• Limitedlifetimewarranty• Availablewithlevers,operatinggripsorexitonly• Allelectricalfunctionsavailable–ElectricUnlatching,FailSafe,ElectricPanic• FactoryinstalledasanintegralpartoftheTotalDoorsystem• Cycletestedtoover5millioncyclesversus500thousandrequired byBHMAandANSIstandardsforexitdevices

3.02

SPECIFICATIONS

Page 49: Product Guide 6.1.2015

Section 3 - Hardware:

PF 200 Flush Exit Device

Lengths

Height

Projection

Centerline from bottom of door

Finishes

• 24”Forwidthof2’5”andwider• 14”Forwidthof1’7”to2’4-15/16

• 4-3/8”

• 5/8”Closed1/8”Open

• 39-9/16”StandardHeight• 34-9/16”ElementaryHeight

• 628SatinAnodizedAluminum• 710DarkBronzeAnodized• 711BlackAnodized• Inserttomatchdoorbody• Architecturalmetalinserts: 629,630,707,667,710

Push Pad

• ADAcompliant• Fireratedupto3hours• Limitedlifetimewarranty• Availablewithlevers,operatinggripsorexitonly• OnlyElectricalUnlatchingandFailSecurefunctionsavailable• FactoryinstalledasanintegralpartoftheTotalDoorsystem• Cycletestedtoover5millioncyclesversus500thousandrequired byBHMAandANSIstandardsforexitdevices

3.03

SPECIFICATIONS

Door Closed Door Open

Page 50: Product Guide 6.1.2015

Section 3 - Hardware:

Lever 60

Lengths

Height

Projection

Centerline from bottom of door

Finishes

Dogging Options

•5-3/16”

•11/16”

•2-3/4”

•39-9/16”StandardHeight•34-9/16”ElementaryHeight

•605BrightBrass•606SatinBrass•629BrightStainlessSteel•630SatinStainlessSteel•710DarkBronze

•Electric–E-UNL

Lever Mechanisms

• ADAcompliant• Fireratedto3hours• Limitedlifetimewarranty• OperatewithanystandardB/C4cammortisecylinder• Availableinallfunctionsincludingexitdevicesandelectricfunctions• Cycletestedtoover5millioncyclesversusonly1millionrequired byBHMAandANSIstandardsformortiselocks

3.04

SPECIFICATIONS

Page 51: Product Guide 6.1.2015

Section 3 - Hardware:

Lever 82

Lengths

Height

Projection

Centerline from bottom of door

Finishes

Dogging Options

• 4-15/16”

• 11/16”

• 2-1/2”

• 39-9/16”StandardHeight• 34-9/16”ElementaryHeight

• 605BrightBrass• 606SatinBrass• 629BrightStainlessSteel• 630SatinStainlessSteel• 710DarkBronze

• Electric–E-UNL

Lever Mechanisms

• ADAcompliant• Fireratedto3hours• Limitedlifetimewarranty• OperatewithanystandardB/C4cammortisecylinder• Availableinallfunctionsincludingexitdevicesandelectricfunctions• Cycletestedtoover5millioncyclesversusonly1millionrequired byBHMAandANSIstandardsformortiselocks

3.05

SPECIFICATIONS

Page 52: Product Guide 6.1.2015

Section 3 - Hardware:

Lever 83

Lengths

Height

Projection

Centerline from bottom of door

Finishes

Dogging Options

•5-1/8”

•11/16”

•2-3/4”

•39-9/16”StandardHeight•34-9/16”ElementaryHeight

•605BrightBrass•606SatinBrass•629BrightStainlessSteel•630SatinStainlessSteel•710DarkBronze

•Electric–E-UNL

Lever Mechanisms

• ADAcompliant• Fireratedto3hours• Limitedlifetimewarranty• OperatewithanystandardB/C4cammortisecylinder• Availableinallfunctionsincludingexitdevicesandelectricfunctions• Cycletestedtoover5millioncyclesversusonly1millionrequired byBHMAandANSIstandardsformortiselocks

3.06

SPECIFICATIONS

Page 53: Product Guide 6.1.2015

Section 3 - Hardware:

Lever 84

Lengths

Height

Projection

Centerline from bottom of door

Finishes

Dogging Options

•5-1/8”

•11/16”

•2-5/8”

•39-9/16”StandardHeight•34-9/16”ElementaryHeight

•605BrightBrass•606SatinBrass•629BrightStainlessSteel•630SatinStainlessSteel•710DarkBronze

•Electric–E-UNL

Lever Mechanisms

• ADAcompliant• Fireratedto3hours• Limitedlifetimewarranty• OperatewithanystandardB/C4cammortisecylinder• Availableinallfunctionsincludingexitdevicesandelectricfunctions• Cycletestedtoover5millioncyclesversusonly1millionrequired byBHMAandANSIstandardsformortiselocks

3.07

SPECIFICATIONS

Page 54: Product Guide 6.1.2015

Section 3 - Hardware:

M32

Width

Height

Projection

Centerline from bottom of door

Finishes

•2-11/16”

•5-3/4”

•1-7/8”

•39-9/16”StandardHeight•34-9/16”ElementaryHeight

•628SatinAnodizedAluminum•710DarkBronzeAnodized•28MMirrorAnodized

Operating Pull/Push Mechanisms and Trim

• ADAcompliant• Fireratedupto3hours• LimitedLifetimeWarranty• AvailableinallstandardmechanicalfunctionsandElectricalUnlatchingand FailSecureelectricfunctions• Noexteriorfasteners;trimcan’tloosenorfalloff• OperatewithanystandardA/Rcammortisecylinder• FactoryinstalledasanintegralpartoftheTotalDoorsystem• Normallifeexpectancyof5millioncyclesversusonly1millionrequired byBHMAandANSIstandardsformortiselocks

3.08

SPECIFICATIONS

Page 55: Product Guide 6.1.2015
Page 56: Product Guide 6.1.2015
Page 57: Product Guide 6.1.2015

Section 3 - Hardware:

M33

Width

Height

Projection

Centerline from bottom of door

Finishes

•2-11/16”

•5-3/4”

•1”

•39-9/16”StandardHeight•34-9/16”ElementaryHeight

•628SatinAnodizedAluminum•710DarkBronzeAnodized•28MMirrorAnodized

Operating Pull/Push Mechanisms and Trim

• ADAcompliant• Fireratedupto3hours• LimitedLifetimeWarranty• AvailableinallstandardmechanicalfunctionsandElectricalUnlatchingand FailSecureelectricfunctions• Noexteriorfasteners;trimcan’tloosenorfalloff• OperatewithanystandardA/Rcammortisecylinder• FactoryinstalledasanintegralpartoftheTotalDoorsystem• Normallifeexpectancyof5millioncyclesversusonly1millionrequired byBHMAandANSIstandardsformortiselocks

3.09

SPECIFICATIONS

Page 58: Product Guide 6.1.2015

Section 3 - Hardware:

M35

Width

Height

Projection

Centerline from bottom of door

Finishes

•2-11/16”

•5-3/4”

•2-1/4”

•39-9/16”StandardHeight•34-9/16”ElementaryHeight

•628SatinAnodizedAluminum•710DarkBronzeAnodized•28MMirrorAnodized

Operating Pull/Push Mechanisms and Trim

• ADAcompliant• Fireratedupto3hours• LimitedLifetimeWarranty• AvailableinallstandardmechanicalfunctionsandElectricalUnlatchingand FailSecureelectricfunctions• Noexteriorfasteners;trimcan’tloosenorfalloff• OperatewithanystandardA/Rcammortisecylinder• FactoryinstalledasanintegralpartoftheTotalDoorsystem• Normallifeexpectancyof5millioncyclesversusonly1millionrequired byBHMAandANSIstandardsformortiselocks

3.10

SPECIFICATIONS

Page 59: Product Guide 6.1.2015

Section 3 - Hardware:

M52

Width

Height

Projection

Centerline from bottom of door

Finishes

•2-11/16”

•5-3/4”

•3/16”

•39-9/16”StandardHeight•34-9/16”ElementaryHeight

•628SatinAnodizedAluminum•710DarkBronzeAnodized

Operating Pull/Push Mechanisms and Trim

• ADAcompliant• Fireratedupto3hours• LimitedLifetimeWarranty• AvailableinallstandardmechanicalfunctionsandElectricalUnlatchingand FailSecureelectricfunctions• Noexteriorfasteners;trimcan’tloosenorfalloff• OperatewithanystandardA/Rcammortisecylinder• FactoryinstalledasanintegralpartoftheTotalDoorsystem• Normallifeexpectancyof5millioncyclesversusonly1millionrequired byBHMAandANSIstandardsformortiselocks

3.11

SPECIFICATIONS

Page 60: Product Guide 6.1.2015

Section 3 - Hardware:

TDC 96/TDC 96P Concealed Closer

Opening Dimensions

Adjustability

Mounting location

Application Type

Upto135°

Latching,Closing&CushStop

Mortisedintoprailofdoor

Standard TDC 96Pocket TDC 96P

Concealed Closer

• Fireratedto3hours• Adjustabletosizes1through5• Retrofittoexistingframeswithoutmortisingtheframe• Closerarmisinvisiblewhendoorisclosed (TDC96standardswingapplication)• Trackandarmarecolormatchedtodoor’sverticals• ImprovedADAcompliance–camactionis60%moreefficient thanastandardrack&pinioncloser

3.12

SPECIFICATIONS

TDC 96P Standard Swing Application

TDC 96P Pocketed Application

Page 61: Product Guide 6.1.2015
Page 62: Product Guide 6.1.2015
Page 63: Product Guide 6.1.2015

Section 3 - Hardware:

TDC 5051 Door Closer

TDC 5051• ForHeavy-Dutydoors• Universalapplication• Adjustablepowertosizes1through6• Standardadjustableback-checkfunction• Fullplasticstandardcover• Aluminumfinish• MeetsANSIA156.26Grade1

Options• Delayedaction• Heavy-dutyarmsavailableincluding• ForgedStandardArmandCUSHArm

3.13

Power Adjusting ChartCloserPowerSize 1 2 3 4 5 6

ClockwiseTurns -6 -3set 3 712

Page 64: Product Guide 6.1.2015

Section 3 - Hardware:

AFPKT-180 Pocket Door Closer

AFPKT-180

• For180°PocketApplication• Universalapplication• Standardadjustableback-checkfunction• Fullplasticstandardcover• Aluminumfinish• MeetsANSIA156.26Grade1

3.14

Page 65: Product Guide 6.1.2015

Section 3 - Hardware:

TDH 100 Electromagnetic Holder

Wall Mount Armature Lengths

Height

Projection

Holding Force

13/16”to2-13/16”

1-3/8”Diameter

1/8”

40LBS

Features

• FactorymortisedinthedoorasanintegralpartoftheTotalDoorsystem• Pre-wiredtoeliminatetheoutletboxandcoordinationwiththeelectrician• 24VoltDC0.3AMPtransformerisincludedonrequest

3.15

SPECIFICATIONS

Semi-Concealedlooprunsthroughhingeandframe

Electromagnet is mortised in the door

Page 66: Product Guide 6.1.2015

Section 3 - Hardware:

TDH 200 Electromagnetic Holder3.16

TheTDH200doorholderiscomposedofadoormountedcatchplateandafloororwall-mountedelectromagnet.Offersuperiorreliabilitywithbuilt-inprotectionandlowresidualmagnetismsotheyreleaseeasilyeveninapplicationsmeetingADArequirementswithminimalspringforcedoorclosers.Bracketsarenotrequiredforrecessed,flush,orsurfacemounting.Thesurfacemountingboxhasthreeconduit-readyentries.Thecatchplateonthedoorfeaturestwopivotpointsandtwo-wayadjustabilitytofurtherensureperfectalignment.

Features

• U.L.listed• Dualvoltage(24/120V)capabilityreducesstockingrequirements• Lowcurrentdrawallowssavingsonpowersuppliesandbackupbatteries• Optionalextensionrodsareavailabletoaccommodatedeeperdoorto wallconditions• Lowresidualmagnetismallowseasyreleaseofdoor• Allelectricalvalues+10%to–15%• Canbemanuallypulledfromholdopenposition• Silentoperation• Holdingforce35lbnominal• PowderCoatedSilver

Page 67: Product Guide 6.1.2015

Section 3 - Hardware:

Continuous Hinge 3.17

Features

• Reducesairleakage• Fireratedupto3hours• Limitedlifetimewarranty• Minimalthrowintoopening• Retrofitintoexistingframes• Noexposedknucklesorfasteners• Offersopportunitytoplanedoorwiththeframeforabetterfit• Surfacemounts,noframepreprequiredandnoreinforcementrequired• Factorypaintedinanarrayof6standardcolors,withcustomcolorsavailable• Cycletestedtoover5millioncyclesverses2.5millionrequiredbyBHMA andANSIstandards

Page 68: Product Guide 6.1.2015

Section 3 - Hardware:

Continuous Locking Channel3.18

Features

• Reducesairleakage• Providesexceptionalsecurity• Allowsforlessflexinthedoorbody• Factorypaintedinanarrayof6standardcolors,withcustomcolorsavailable• Eliminatesverticalrods,floorhardware,coordinators,astragalsandflushbolts onpairsanddoubleegressdoors• PairsandDoubleEgresslockingchannelengagesurfaceappliedstrikeathead• SingledoorshavefullsurfacelatchstopcomparedtotraditionalASAstrike

Page 69: Product Guide 6.1.2015

Performance Data

Section 4:

Page 70: Product Guide 6.1.2015
Page 71: Product Guide 6.1.2015

Performance Data

Comparative Performance 4.01

Performance Data

R or U Factor 4.02

Sound Transmission Coefficient (STC) 4.02

Additional Agencies Approving ITS 4.02

ITS Report Numbers 4.02

Total Door listed products based on ITS/WHI testing 4.02

Labeled Frames for Total Door Systems® 4.03

Fire Labeling for Existing Frames 4.04

Total Door Systems® Installation & Fire Code Compliance 4.04

Field Undercutting of Labeled Doors 4.04

Application of Architectural Films and Wood Veneer 4.04

Total Door Systems® Limited Warranty 4.05

Procedure for Issue 4.06

4S E C T I O N

Page 72: Product Guide 6.1.2015
Page 73: Product Guide 6.1.2015

Section 4 - Performance Data:

Comparative Performance 4.01

Total Door Systems® vs. Standard Doors & Hardware

Standard doors and hardware are not tested as a system, but rather as individual components, each tested in isolation under perfect conditions in a laboratory. TOTAL DOOR SYSTEMS®, on the other hand, has been tested as it is used in the field, that is, as a complete system – door, body, hinge, frame, locking mechanism, panic device, locking channel, etc.

It is significant and important to note that W.H.I. cycle tested a labeled pair of doors with panics to 10 times the standard number of cycles (1,000,000) and found only insignificant wear (.003”). The doors required no lubrication, and no maintenance during the long test.

ANSI/BHMA Minimum Federal Performance Standards vs. Total Door Systems

0 1 2 3 4 5

Cycles in Millions

Industry Standard Total Door Systems

Not required with Total Doors

Not required with Total Doors

Frames

4 Ball Bearing Hinge

Steel Door

Wood Door

Mortise Lock

Cylindrical Lock

Panics

Coordinators

Flush Bolts

Page 74: Product Guide 6.1.2015

Section 4 - Performance Data:

Performance Data4.02

R-Value or U-Factor

Standard construction steel doors have insulating values as follows:

R-Value = measure of the rate at which heat flows through 1sq ft of material = 4.76U-Factor = measures the resistance to heat flow = .21

Insulating doors should be gasketed to prevent air infiltration.

Sound Transmission Coefficient

According to test results, TOTAL DOOR SYSTEMS® when fully gasketed, will provide a STC (sound transmission coefficient) rating as follows:

18 gauge steel x polystyrene core = 33 STC18 gauge steel x temperature rise core = 35 STC

Underwriters Laboratories – R7764

ITS Approval by Additional Agencies

ITS, our fire rating Testing Laboratory, has been evaluated and approved by other agencies as well, including the following:

• Standards Council of Canada• Fire Marshal of the State of California #3555-0855:100, 101 & 102• City of Chicago

ITS Report Numbers

We operate under the umbrella of ITS/WHI approvals

ITS report numbers for TOTAL DOOR SYSTEMS® are:

Steel TypeReport Numbers: 495-0205 (7/79) 495-0483 (3/83)

Total Door Listed Products Based on ITS/WHI Testing

Intertek Testing Services has fire, smoke infiltration, and cycle tested the TOTAL DOOR manufacturedby Total Door Systems®, of Waterford, Michigan, and has certified the following for positive pressure fire resistance compliance under UBC Standard 7-2 (1997) Parts I and II, UL 10C (1998), UL 1784 (2004) and NFPA 252 (1999).

(Standard doors and hardware are not tested as a system, but rather as individual components, eachtested in isolation under perfect conditions in a laboratory. Total Door Systems®, on the other hand, has been tested as it is used in the field, that is, as a complete system – door, body, hinge, frame, lockingmechanism, panic device, locking channel, etc.)

Page 75: Product Guide 6.1.2015

Section 4 - Performance Data:

Performance Data (continued) 4.03

Total Door Listed Products Based on ITS/WHI Testing (continued)

Frames:

All frame constructions shown in UL 63 are usable with Total Door Systems. Total Doors may be usedwith all labeled frames of any manufacturer. Total Doors may be retrofitted to any existing labeledframes that are structurally sound.

Tubular 2” x 2” or larger steel tube, 20 minute to 3 hour, with applied head stop, for single, pair or double egress, to maximum size of 8’ 4-3/8” x 10’ 0”.

Note: Total Doors, single, pair or double egress, up to 1-1/2 hour, may be mounted directly on masonrywithout the use of a metal frame.

Misc:

Closers Mortised and surface applied closers are approved for all fire ratings including three (3) hour.

Electric Electric doors, with inclusion of a solenoid for remote control of locking/latching is approved on all labels as part of the door system. A separate label for the solenoid is not required.

Holders Mortised semi-concealed electromagnetic holder mounted in the door for all labels.

Lead One-sixteenth inch lead-lined doors are available in all labels on steel doors of up to 28 square feet in single swing. Pairs of doors may be any size up to 4’0” x 7’0” with maximum 1/32” thick lead.

Lights Labeled vision lights on all fire doors with lite kits labeled for Positive Pressure, under standard installation procedures when acceptable to the Authority having Jurisdiction.

Kickplates Kickplates of any height, when using Total Door Systems® standard bonded wraparound kickplates without mechanical fasteners for all labels.

Panics Panic exit devices have been tested for compliance to UL305 door for all labels.

Pockets Pocket door applications using any closer labeled for positive pressure. When the closer is mounted on the wall, the wall must be reinforced and the closer installed per the Total Door Systems® installation drawings. The certification applies to 90 degree through 180 degree installations.

Smoke & Draft The S mark signifying the acceptance to UBC Standard 7- 2 (1997) Part II may be applied to the label. UL 1784 (2004), results were below the maximum 3.0 cubic feet per minute per square foot which is not to exceed.

Special finishes All labeled steel doors including temperature rise may have Architectural film, genuine wood veneers, FRP, stainless steel, aluminum or brass faces one or both sides.

Labeled Frames for TOTAL DOOR SYSTEMS®

The TOTAL DOOR SYSTEMS® hinge and locking system actually stiffen the frame. That is why even pair and double egress configurations pass fire tests using a simple cased (non-rabbetted) frame with ZERO deflection of the door to frame during the fire test. Conventional labeled steel doors separate from the frame over 2” and are still given a fire label. By always testing with a generic cased frame, we are automatically allowed by WHI and UL to use single or double rabbetted frames because they are considered stronger and stiffer than a cased frame.

Page 76: Product Guide 6.1.2015

Section 4 - Performance Data:

Performance Data (continued)4.04

Labeled Frames for TOTAL DOOR SYSTEMS® (continued)

A labeled TOTAL DOOR SYSTEMS® can be installed in any WHI or UL rated frame. Even if the hinge reinforcements are broken, if the frame is structurally sound, you can properly install a WHI labeled TOTAL DOOR SYSTEMS®.

Fire Labeling Existing Door Frames

ITS can label existing door frames that are missing labels. On retrofit jobs, you do not have to replace the frame simply to obtain a labeled frame. ITS will examine and inspect door frames and if found to be eligible, they will affix a fire rating label to the door frame. ITS requests that a representative accompany them to locate the door openings to be inspected. Also during the inspection, they will require the assistance of a locksmith, door tradesman or building mechanic to provide assistance in fastening labels to the frame by drilling two 1/8” holes and installing drive rivets. WHI also requests that a local building inspector be on site to observe its examination, inspection and labeling procedures. You can contact ITS at: (608) 836-4400, Fax (608) 831-9279

TOTAL DOOR SYSTEMS® labels are found on the TOP edge of the door.

TOTAL DOOR SYSTEMS® Installation & Fire Code Compliance

With the TOTAL DOOR SYSTEMS® product line, the installation instructions and caveats are part of the listed procedure. In other words, violating the TOTAL DOOR SYSTEMS® installation instructions voids the label of the opening. If TOTAL DOOR SYSTEMS ® are not installed by a factory certified installer, the warranty will be void. In the event that a warranty is issued without careful inspection, its issuance is invalid.

If the opening is not labeled, the Fire Marshal is obligated to deny issuance of an occupancy permit. If he is unaware of this, an anonymous communication to UL or ITS will make the Fire Marshal aware of the condition.

Field Undercutting of Labeled Doors

Warnock Hersey has ruled that 1 ½ hour B, 3/4 hour (C), and 20 Minute Rated steel TOTAL DOOR SYSTEMS® may be cut off in the field a maximum of 3/4”. Three hour (A) label doors may not be cut off at all.

Application of Architectural Films and Wood Veneers to Labeled Steel TOTAL DOOR SYSTEMS®

The construction and bonding processes that TOTAL DOOR SYSTEMS® uses in the factory on labeled wood veneer steel doors, can only be done under license and with testing lab follow-up.

Field application of cladding or wood veneers to labeled TOTAL DOOR SYSTEMS® will void anyfire rating.

Page 77: Product Guide 6.1.2015
Page 78: Product Guide 6.1.2015
Page 79: Product Guide 6.1.2015

Limited Warranty

This limited warranty covers the materials and workmanship of its products manufactured after January 1, 1997 as follows for two and one-half (2-1/2) years from the ship date or two (2) years from the installation date, whichever occurs first:

• Door Bodies - two (2) years. • Electrical Components - two (2) years.• Locks: mortise lock bodies and push/pull mechanisms (Q289SA, M22SA & M24SA) - for the lifetime of the original installation.• Exit Devices Panic Buttons (P16SA) - for the lifetime of the original installation.• Hanger Rods (H17, H50 - Standard Black or white) - for the lifetime of the original installation.• Retainers (R12SA) - for the lifetime of the original installation.• Flush Panic Actuator (PF221B with X35 Screw) - for the lifetime of the original installation.• Hinge (H-13) - for the lifetime of the original installation.

This limited warranty shall apply only if the product is properly stored, installed and maintained in accordance with Total Doors’ written instructions. Total Door will, at its option, replace, repair or refund the purchase price paid to Total Door for products which in its opinion, are found to be defective in workmanship or material under normal use and service within the above defined time periods. Total Doors’ sole responsibility is as stated herein and it shall not be liable for consequential, indirect or incidental damages.

This limited warranty is in place of all other warranties, express or implied, and excludes any warranties of fitness or merchantability. No agent, representative, dealer, or employee of Total Door has the authority to increase or alter the obligations of this limited warranty.

Notice Requirement

Purchaser is responsible for inspection of product upon receipt and for giving written notice to supplier and Total Door within 30 days of discovery of unsatisfactory performance.

Storage and Handling Instructions

1. Store Total Doors flat on a level surface in a dry, well ventilated building, separated by spacer blocks provided with original shipment so that no projecting hardware touches any part of an adjacent door.2. Cover doors to keep clean and avoid discoloration. Cover must allow air circulation.3. Wood doors or steel doors with wood faces should not be subjected to extremes of heat and/or humidity conditions. Relative humidity should not be less than 30% or more than 60%. 4. Wood finished doors, follow manufacturer’s special handling and finishing instructions that apply to wood finished doors.5. Handle with clean gloves and do not drag doors across one another or across other surfaces.

Installation

Total Doors must be installed in full compliance with manufacturer’s written instructions.

Maintenance

To assure coverage under this limited warranty, the following must be maintained: the adjustment of hardware and fasteners attached to or fitted into the doors or frame, the finishes on all wood surfaces and the moisture protection on exterior doors.

Exclusions

This limited warranty does not include:

• Total Doors that are not installed by a factory certified installer. If a warranty was previously issued the warranty is void.• Total Doors that are not installed to factory specified tolerances. • Any products which, in the opinion of Total Door, have been modified, repaired or altered in any way without the express written consent of the Company.• The appearance of field finished doors.• The appearance of high gloss surfaced doors.• Natural variations in the color or texture of wood.• Doors with cutouts for lights, louvers or other hardware nearer than six inches to the door edge, or doors with less than six inches between cutouts.• Normal wear and tear including wear-through of finishes or deterioration for reasons other than material and workmanship.• Items by other manufacturers.• Wood surfaced doors exposed to relative humidity of less than 30% or greater than 60%.• Field Painting of Hinge Verticals (H12 or H13 or H14 or H15).• Field Paint of Locking Channel Verticals (L11).

Exclusions for Exterior Doors

An exterior door is one that cannot be controlled on both sides for temperature and humidity. The following conditions will void the limited warranty:

• Use of concealed closers.• Wood or plastic faced doors.• Doors and frames not properly protected by flashing or drip caps.• Doors that are not sealed top and bottom.

Total Door Systems / 800.852.6660 / www.totaldoor.com

4.05

Page 80: Product Guide 6.1.2015

4.06 Limited Warranty

Procedure for Issue

To receive a TOTAL DOOR SYSTEMS® Limited Warranty, the distributor must forward the following information to TOTAL DOOR SYSTEMS®:

1. Total Door Systems Order Number: ...................................................................................................................................................... ............

2. Job Site Name: .................................................................................................................................................... ...........................................................

3. Date of Installation: ..................................................................................................................................................... ................................................

4. Name of Distributor: .................................................................................................................................................... ................................................

5. The Installer (insert name)........................................................................... has been trained and certified from the factory to install Total Door systems. 6. I, ........................................................................... have reviewed the entire job to insure that all doors have been installed to factory specifications.

................................................................................................ signature

........................................................................... ....................date

Page 81: Product Guide 6.1.2015

Specifications & CAD Drawings

Section 5:

Page 82: Product Guide 6.1.2015
Page 83: Product Guide 6.1.2015

Specifications & CAD Drawings

Pair 5.01

Double Egress 5.10

Elevator 5.19

5S E C T I O N

5.01

5.10

5.19

Page 84: Product Guide 6.1.2015
Page 85: Product Guide 6.1.2015

Section 5 - Specifications & CAD Drawings:

Section 081700 - Integrated Metal Door Opening Systems

Pair Application: Part 1: General1.01 GENERAL NOTE A. The General Conditions, Supplementary General Conditions, and Division 1 - General Requirements are hereby made a part of this Section as fully as if repeated herein.

1.02 SUMMARY A. Section Includes

1. Integrated metal door opening assemblies with doors, operating hardware, accessories, and installation for a complete assembly.

1.03 RELATED SECTIONS A. Section 01 33 00, Submittal Procedures.

B. Section 01 25 13, Product Substitution Procedures.

1.04 REFERENCES A. ANSI/BHMA A156.3 – Exit Devices, American National Standards Institute/ Building Hardware Manufacturers Association, 2001.

B. ANSI/BHMA A156.4 – Closers, American National Standards Institute/ Building Hardware Manufacturers Association, 2000.

C. ANSI/BHMA A156.13 – Mortise Locks/Latches, American National Standards Institute/ Building Hardware Manufacturers Association, 2002.

D. ANSI/BHMA A156.26 – Continuous Hinges, American National Standards Institute/ Building Hardware Manufacturers Association, 2000.

E. ANSI/SDI - A250.8 Recommended Specifications for Standard Steel Doors and Frames, American National Standards Institute/Steel Door Institute, 2003.

F. ANSI/UL 10C -- Positive Pressure Fire Tests of Door Assemblies, American National Standards Institute/Underwriters Laboratories, 2001.

G. ASTM A1008 - Standard Specification for Steel, Sheet, Cold-Rolled, Carbon, Structural, High-Strength Low-Alloy and High-Strength Low-Alloy with Improved Formability, American Society of Testing and Materials; 2004a.

H. AWI AWQS - Architectural Woodwork Quality Standards P-208; The Architectural Woodwork Institute; 8th Edition.

I. NFPA 101 – Life Safety Code, National Fire Protection Association, 2003.

J. NFPA 252 - Standard Methods of Fire Tests of Door Assemblies, National Fire Protection Association, 2003.

K. SDI 111 A - Recommended Steel Door Frame Details, Steel Door Institute; 2002.

L. SDI 112 - Zinc-Coated (Galvanized/Galvannealed) Standard Steel Doors and Frames, Steel Door Institute, 1997.

M. UL 305 - Standard for Panic Hardware, Underwriters Laboratories Inc., 1997

1.05 SYSTEM DESCRIPTION A. Performance Requirements

1. Integrated metal door opening assemblies: Exceed minimum performance standards.

a. Steel Doors: In accordance with ANSI/SDI A250.8, Grade 1, but not less than 5,000,000 cycles. b. Exit Devices: In accordance with ANSI/BHMA A156.3, Grade 1, but not less than 5,000,000 cycles. c. Closers: In accordance with ANSI/BHMA A156.4, Grade 1. d. Mortise Locks/Latches: In accordance with ANSI/ BHMA A156.13, Grade 1, but not less than 5,000,000 cycles. e. Full-height Hinges: In accordance with ANSI/ BHMA A156.26, Grade 1, but not less than 5,000,000 cycles.

5.01

Page 86: Product Guide 6.1.2015

Section 5 - Specifications & CAD Drawings:

Section 081700 - Integrated Metal Door Opening Systems

Pair Application: Part 1: General (cont.)

1.06 SUBMITTALS A. Shop Drawings

1. In accordance with Section 01 33 00. 2. Indicate each door and frame condition; frame type, profile and installation detail; items of finish hardware, finishes and electrical roughin requirements.

B. Samples

1. In accordance with Section 01 33 00.

1.07 QUALITY ASSURANCE A. Qualifications

1. Manufacturer: Firm with not less than 5 years successful experience in fabrication of integrated metal door opening assemblies with full-height latch/lock and full-height hinge. 2. Supplier: Authorized distributor of manufacturer. 3. Installer: Manufacturer certified.

B. Regulatory Requirements

1. Rated door assemblies shall have been tested to meet conditions of NFPA 252 as required by NFPA 101 section 6-2.3.3.

1.08 DELIVERY, STORAGE AND HANDLING A. Packaging: Polyvinyl wrapped, palette by floor, and clearly marked for each opening.

B. Delivery: Deliver to site in original unopened containers and pallets bearing system manufacturers name, and brand.

C. Store: Horizontally on level surface, not less than 2 inches off floor in a clean, dry well-ventilated area protected from sunlight, extreme heat, dryness and moisture.

D. Receiving, off loading, and site distribution should be handled by an authorized Total Door Distributor unless otherwise stipulated by contract. If the G.C. or other entity handles all or any portion of the receiving, off loading, and site distribution, they are held responsible for any and all damages that may result from potential miss handling of the product.

1.09 PROJECT CONDITIONS A. Do not bring door systems to site until building temperature and humidity ranges are compatible with recommended values for preservation of wood moisture content as listed by AWI AWQS. Building shall be stabilized at 30 to 60 percent humidity.

1.10 WARRANTY A. Integrated metal door opening assembly: Manufacturer’s standard 2 year warranty against defects in material and workmanship.

B. Locksets, hanger rods, and panic exit devices: Manufacturer’s lifetime limited warranty against defects in material and workmanship.

C. Store doors in a clear, dry ventilated space having controlled temperature and a relative humidity range between 30 and 60 percent. Stack doors flat and off the floor to prevent warpage.

5.02

Page 87: Product Guide 6.1.2015

Section 5 - Specifications & CAD Drawings:

Section 081700 - Integrated Metal Door Opening Systems

Pair Application: Part 2: Products2.01 MANUFACTURERS A. Integratedmetaldoorsystems

1. TotalDoor:www.totaldoor.com 2. Substitutions:RefertoSection012513,Notpermitted.

B. Hardware

1. TotalDoor:www.totaldoor.com 2. Substitutions:RefertoSection012513,Notpermitted.

2.02 MATERIALS A. Frames

1. Tobesuppliedbyothers. 2. InaccordancewithANSI/SDIA250.8,SDI111A,andSDI112. 3. Construction:All-weldedunit,type. 4. Material:Steel,coldrolled,ASTMA1008,16gauge. 5. FireResistanceRating:WhereindicatedinContractDocumentsfordoors. 6. SpreaderBar:Removable,atsill.

B. FrameAnchorageDevices

1. Tosecurelyfastentowallconstructionwithoutdistortionorstress. 2. InaccordancewithfireresistanceratingindicatedinContractDocuments.

C. DoorSystems

1. InaccordancewithANSI/SDIA250.8.

2. GeneralUse–Interior,Exterior&FireRated

a. Stiles:Steel,galvannealed,16gauge,spotwelded. b. TopandBottomRails:5-1/2inch18gaugesteelrails. c. Cores: 1. Solidpolystyrenecontinuouslybondedtofaces. 2. TemperatureRise. d. Thickness:1-3/4inches. e. Faces:Steel,stretcherleveled,withoutseamsorspotwelds,galvannealed20gauge. f. Weldpattern:Enhancedinaccordancewithmanufacturesstandarddetails.

3. Gasketing

a. U.L.approvedforfiredoors. b. Jambs:Factoryappliedtolatch/lockingchannels.

2.03 FINISHES A. HingeandLockingChannel

1. Finish:2partinfraredbakedpolyurethanepaint. a. ColortobeselectedbyArchitect.

B. DoorFaces,Interior

1. Finish:TobeselectedbyArchitect,refertodoorschedule.

2.04 FABRICATION A. UnlessmodifiedbyContractDocuments,constructintegratedmetaldooropeningassembliesin accordancewithmanufacturer’spublishedspecificationsandapplicableCoderequirements.

B. Factoryassemblewithfull-heighthingesandlatching/lockingchannels,locksets,exitdevices, closers,litekits,glazing,kickplates,stretcherplates,andarmorplates.

5.03

Page 88: Product Guide 6.1.2015

Section 5 - Specifications & CAD Drawings:

Section 081700 - Integrated Metal Door Opening Systems

Pair Application: Part 3: Execution3.01 EXAMINATION A. Field Conditions

1. Prior to commencing installation, examine parts of building structure, which are to receive door systems and component parts.

2. Report, in writing, conditions which would prevent proper execution or endanger permanency of the work to the Architect.

B. Field Dimensions

1. Where possible, verify frame tolerances before fabrication of door systems.

2. Notify Architect of variances with reviewed shop drawings.

C. Corrective measures, when necessary, shall be determined and approved prior to commencing fabrication.

D. Coordinate door opening assembly details with adjacent work to assure proper attachments, clean junctions, etc.

3.02 INSTALLATION A. Install work in accordance with Contract Documents and reviewed shop drawings.

1. Install door systems and hardware in accordance with manufacturer’s recommendations.

2. Deliver frames to be installed by others.

B. Frames

1. Set plumb and square in accordance with DHI standards.

a. Out-of-square at frame head: Not to exceed 1/16 inch. b. Out-of-plumb for each frame jamb: Not to exceed 1/16 inch. c. Out-of-alignment for each side in plan: Not to exceed 1/16 inch. d. Twist dimension: ºNot to exceed 1/16 inch.

2. Brace until adjacent wall is constructed.

3. Securely anchor to adjacent wall.

4. Furnish and install clips, fastenings, and anchorages and conceal unless otherwise noted.

C. Door Systems

1. Hang to maintain manufacturer’s installation tolerances.

2. Adjust to freely swing without binding, sticking, or sagging, and to eliminate excessive clearances.

D. Hardware: When installation is otherwise complete, adjust hardware for proper operation and function.

5.04

Page 89: Product Guide 6.1.2015

Section 5 - Specifications & CAD Drawings:

Section 081700 - Integrated Metal Door Opening Systems

Pair Application: Part 4: System Schedule

Set 90° Hold Open

2 ea Full Height Hinges H-13 Rigidized Color TBD Total Door

2 ea Full Height Latch Channel L- 11 Color TBD Total Door

2 ea Operating Pulls M32 628 Total Door

2 ea Exit Device/insert to match skin PF200 (Flush Panic) 628 Total Door

2 ea Closer TDC96P Alum Total Door

2 ea Mag Holder TBD

2 ea Positive Pressure label (confirm rating with door schedule) Total Door (Stairwells may require a temperature rise rating)

Set 180° Hold Open

2 ea Full Height Hinges H-13 Color TBD Total Door

2 ea Full Height Latch Channel L- 11 Color TBD Total Door

2 ea Operating Pulls M32 628 Total Door

2 ea Exit Device/insert to match skin PF200 (Flush Panic) 628 Total Door

2 ea Closer AFPKT-180 Alum Total Door

2 ea Mag Holder TBD

2 ea Positive Pressure label (confirm rating with door schedule) Total Door (Stairwells may require a temperature rise rating)

Set 90/180° – 180/90° Hold Open

2 ea Full Height Hinges H-13 Rigidized (1) Color TBD Total Door

2 ea Full Height Latch Channel L- 11 Color TBD Total Door

2 ea Operating Pulls M32 628 Total Door

2 ea Exit Device/insert to match skin PF200 (Flush Panic) 628 Total Door

1 ea Closer TDC96P Alum Total Door

1 ea Closer AFPKT-180 Alum Total Door

2 ea Mag Holder TBD

2 ea Positive Pressure label (confirm rating with door schedule) Total Door (Stairwells may require a temperature rise rating)

5.05

Page 90: Product Guide 6.1.2015
Page 91: Product Guide 6.1.2015

Section 5 - Specifications & CAD Drawings:

Integrated Metal Door Opening Systems

Sheet No - PR-HO-90

5.06

©2015, Total Door Systems

Page 92: Product Guide 6.1.2015

Section 5 - Specifications & CAD Drawings:

Integrated Metal Door Opening Systems

Sheet No - PR-HO-180

5.07

©2015, Total Door Systems

Page 93: Product Guide 6.1.2015

Section 5 - Specifications & CAD Drawings:

Integrated Metal Door Opening Systems

Sheet No - PR-HO-90-180

5.08

©2015, Total Door Systems

Page 94: Product Guide 6.1.2015

Section 5 - Specifications & CAD Drawings:

Integrated Metal Door Opening Systems

Sheet No - PR-HO-180-90

5.09

©2015, Total Door Systems

Page 95: Product Guide 6.1.2015
Page 96: Product Guide 6.1.2015
Page 97: Product Guide 6.1.2015

Section 5 - Specifications & CAD Drawings:

Section 081700 - Integrated Metal Door Opening Systems

Double Egress Application: Part 1: General1.01 GENERAL NOTE A. The General Conditions, Supplementary General Conditions, and Division 1 - General Requirements are hereby made a part of this Section as fully as if repeated herein.

1.02 SUMMARY A. Section Includes

1. Integrated metal door opening assemblies with doors, operating hardware, accessories, and installation for a complete assembly.

1.03 RELATED SECTIONS A. Section 01 33 00, Submittal Procedures.

B. Section 01 25 13, Product Substitution Procedures.

1.04 REFERENCES A. ANSI/BHMA A156.3 – Exit Devices, American National Standards Institute/ Building Hardware Manufacturers Association, 2001.

B. ANSI/BHMA A156.4 – Closers, American National Standards Institute/ Building Hardware Manufacturers Association, 2000.

C. ANSI/BHMA A156.13 – Mortise Locks/Latches, American National Standards Institute/ Building Hardware Manufacturers Association, 2002.

D. ANSI/BHMA A156.26 – Continuous Hinges, American National Standards Institute/ Building Hardware Manufacturers Association, 2000.

E. ANSI/SDI - A250.8 Recommended Specifications for Standard Steel Doors and Frames, American National Standards Institute/Steel Door Institute, 2003.

F. ANSI/UL 10C -- Positive Pressure Fire Tests of Door Assemblies, American National Standards Institute/Underwriters Laboratories, 2001.

G. ASTM A1008 - Standard Specification for Steel, Sheet, Cold-Rolled, Carbon, Structural, High-Strength Low-Alloy and High-Strength Low-Alloy with Improved Formability, American Society of Testing and Materials; 2004a.

H. AWI AWQS - Architectural Woodwork Quality Standards P-208; The Architectural Woodwork Institute; 8th Edition.

I. NFPA 101 – Life Safety Code, National Fire Protection Association, 2003.

J. NFPA 252 - Standard Methods of Fire Tests of Door Assemblies, National Fire Protection Association, 2003.

K. SDI 111 A - Recommended Steel Door Frame Details, Steel Door Institute; 2002.

L. SDI 112 - Zinc-Coated (Galvanized/Galvannealed) Standard Steel Doors and Frames, Steel Door Institute, 1997.

M. UL 305 - Standard for Panic Hardware, Underwriters Laboratories Inc., 1997.

1.05 SYSTEM DESCRIPTION A. Performance Requirements

1. Integrated metal door opening assemblies: Exceed minimum performance standards.

a. Steel Doors: In accordance with ANSI/SDI A250.8, Grade 1, but not less than 5,000,000 cycles.

b. Exit Devices: In accordance with ANSI/BHMA A156.3, Grade 1, but not less than 5,000,000 cycles.

c. Closers: In accordance with ANSI/BHMA A156.4, Grade 1.

d. Mortise Locks/Latches: In accordance with ANSI/ BHMA A156.13, Grade 1, but not lessnthan 5,000,000 cycles.

e. Full-height Hinges: In accordance with ANSI/ BHMA A156.26, Grade 1, but not less than 5,000,000 cycles.

5.10

Page 98: Product Guide 6.1.2015

Section 5 - Specifications & CAD Drawings:

Section 081700 - Integrated Metal Door Opening Systems

Double Egress Application Part 1: General (cont.)

1.06 SUBMITTALS A. Shop Drawings

1. In accordance with Section 01 33 00. 2. Indicate each door and frame condition; frame type, profile and installation detail; items of finish hardware, finishes and electrical roughin requirements.

B. Samples

1. In accordance with Section 01 33 00.

1.07 QUALITY ASSURANCE A. Qualifications

1. Manufacturer: Firm with not less than 5 years successful experience in fabrication of integrated metal door opening assemblies with full-height latch/lock and full-height hinge. 2. Supplier: Authorized distributor of manufacturer. 3. Installer: Manufacturer certified.

B. Regulatory Requirements

1. Rated door assemblies shall have been tested to meet conditions of NFPA 252 as required by NFPA 101 section 6-2.3.3.

1.08 DELIVERY, STORAGE AND HANDLING A. Packaging: Polyvinyl wrapped, palette by floor, and clearly marked for each opening.

B. Delivery: Deliver to site in original unopened containers and pallets bearing system manufacturers name, and brand.

C. Store: Horizontally on level surface, not less than 2 inches off floor in a clean, dry well-ventilated area protected from sunlight, extreme heat, dryness and moisture.

D. Receiving, off loading, and site distribution should be handled by an authorized Total Door Distributor unless otherwise stipulated by contract. If the G.C. or other entity handles all or any portion of the receiving, off loading, and site distribution, they are held responsible for any and all damages that may result from potential miss handling of the product.

1.09 PROJECT CONDITIONS A. Do not bring door systems to site until building temperature and humidity ranges are compatible with recommended values for preservation of wood moisture content as listed by AWI AWQS. Building shall be stabilized at 30 to 60 percent humidity.

1.10 WARRANTY A. Integrated metal door opening assembly: Manufacturer’s standard 2 year warranty against defects in material and workmanship.

B. Locksets, hanger rods, and panic exit devices: Manufacturer’s lifetime limited warranty against defects in material and workmanship.

C. Store doors in a clear, dry ventilated space having controlled temperature and a relative humidity range between 30 and 60 percent. Stack doors flat and off the floor to prevent warpage.

5.11

Page 99: Product Guide 6.1.2015

Section 5 - Specifications & CAD Drawings:

Section 081700 - Integrated Metal Door Opening Systems

Double Egress Application: Part 2: Products2.01 MANUFACTURERS A. Integratedmetaldoorsystems

1. TotalDoor:www.totaldoor.com 2. Substitutions:RefertoSection012513,Notpermitted.

B. Hardware

1. TotalDoor:www.totaldoor.com 2. Substitutions:RefertoSection012513,Notpermitted.

2.02 MATERIALS A. Frames

1. Tobesuppliedbyothers. 2. InaccordancewithANSI/SDIA250.8,SDI111A,andSDI112. 3. Construction:All-weldedunit,type. 4. Material:Steel,coldrolled,ASTMA1008,16gauge. 5. FireResistanceRating:WhereindicatedinContractDocumentsfordoors. 6. SpreaderBar:Removable,atsill.

B. FrameAnchorageDevices

1. Tosecurelyfastentowallconstructionwithoutdistortionorstress. 2. InaccordancewithfireresistanceratingindicatedinContractDocuments.

C. DoorSystems

1. InaccordancewithANSI/SDIA250.8.

2. GeneralUse–Interior,Exterior&FireRated

a. Stiles:Steel,galvannealed,16gauge,spotwelded. b. TopandBottomRails:5-1/2inch18gaugesteelrails. c. Cores: 1. Solidpolystyrenecontinuouslybondedtofaces. 2. TemperatureRise. d. Thickness:1-3/4inches. e. Faces:Steel,stretcherleveled,withoutseamsorspotwelds,galvannealed20gauge. f. Weldpattern:Enhancedinaccordancewithmanufacturesstandarddetails.

3. Gasketing

a. U.L.approvedforfiredoors. b. Jambs:Factoryappliedtolatch/lockingchannels.

2.03 FINISHES A. HingeandLockingChannel

1. Finish:2partinfraredbakedpolyurethanepaint. a. ColortobeselectedbyArchitect.

B. DoorFaces,Interior

1. Finish:TobeselectedbyArchitect,refertodoorschedule.

2.04 FABRICATION A. UnlessmodifiedbyContractDocuments,constructintegratedmetaldooropeningassembliesin accordancewithmanufacturer’spublishedspecificationsandapplicableCoderequirements.

B. Factoryassemblewithfull-heighthingesandlatching/lockingchannels,locksets,exitdevices, closers,litekits,glazing,kickplates,stretcherplates,andarmorplates.

5.12

Page 100: Product Guide 6.1.2015

Section 5 - Specifications & CAD Drawings:

Section 081700 - Integrated Metal Door Opening Systems

Double Egress Application: Part 3: Execution3.01 EXAMINATION A. Field Conditions

1. Prior to commencing installation, examine parts of building structure, which are to receive door systems and component parts.

2. Report, in writing, conditions which would prevent proper execution or endanger permanency of the work to the Architect.

B. Field Dimensions

1. Where possible, verify frame tolerances before fabrication of door systems.

2. Notify Architect of variances with reviewed shop drawings.

C. Corrective measures, when necessary, shall be determined and approved prior to commencing fabrication.

D. Coordinate door opening assembly details with adjacent work to assure proper attachments, clean junctions, etc.

3.02 INSTALLATION A. Install work in accordance with Contract Documents and reviewed shop drawings.

1. Install door systems and hardware in accordance with manufacturer’s recommendations.

2. Deliver frames to be installed by others.

B. Frames

1. Set plumb and square in accordance with DHI standards.

a. Out-of-square at frame head: Not to exceed 1/16 inch. b. Out-of-plumb for each frame jamb: Not to exceed 1/16 inch. c. Out-of-alignment for each side in plan: Not to exceed 1/16 inch. d. Twist dimension: Not to exceed 1/16 inch.

2. Brace until adjacent wall is constructed.

3. Securely anchor to adjacent wall.

4. Furnish and install clips, fastenings, and anchorages and conceal unless otherwise noted.

C. Door Systems

1. Hang to maintain manufacturer’s installation tolerances.

2. Adjust to freely swing without binding, sticking, or sagging, and to eliminate excessive clearances.

D. Hardware: When installation is otherwise complete, adjust hardware for proper operation and function.

5.13

Page 101: Product Guide 6.1.2015

Section 5 - Specifications & CAD Drawings:

Section 081700 - Integrated Metal Door Opening Systems

Double Egress Application: Part 4: System Schedule

Set 90° Hold Open

2 ea Full Height Hinges H-13 Rigidized Color TBD Total Door

2 ea Full Height Latch Channel L- 11 Color TBD Total Door

2 ea Exit Device/insert to match skin PF200 (Flush Panic) 628 Total Door

2 ea Closer TDC96P Alum Total Door

2 ea Mag Holders TBD

2 ea Positive Pressure label (confirm rating with door schedule) Total Door (Stairwells may require a temperature rise rating)

Set 180° Hold Open

2 ea Full Height Hinges H-13 Color TBD Total Door

2 ea Full Height Latch Channel L- 11 Color TBD Total Door

2 ea Exit Device/insert to match skin PF200 (Flush Panic) 628 Total Door

2 ea Closer AFPKT-180 Alum Total Door

2 ea Mag Holder TBD

2 ea Positive Pressure label (confirm rating with door schedule) Total Door (Stairwells may require a temperature rise rating)

Set 90/180° – 180/90° Hold Open

2 ea Full Height Hinges H-13 Rigidized (1) Color TBD Total Door

2 ea Full Height Latch Channel L- 11 Color TBD Total Door

2 ea Exit Device/insert to match skin PF200 (Flush Panic) 628 Total Door

1 ea Closer TDC96P Alum Total Door

1 ea Closer AFPKT-180 Alum Total Door

2 ea Mag Holder TBD

2 ea Positive Pressure label (confirm rating with door schedule) Total Door (Stairwells may require a temperature rise rating)

5.14

Page 102: Product Guide 6.1.2015
Page 103: Product Guide 6.1.2015

Section 5 - Specifications & CAD Drawings:

Integrated Metal Door Opening Systems

Sheet No - DE-HO-90

5.15

©2015, Total Door Systems

Page 104: Product Guide 6.1.2015

Section 5 - Specifications & CAD Drawings:

Integrated Metal Door Opening Systems

Sheet No - DE-HO-180

5.16

©2015, Total Door Systems

Page 105: Product Guide 6.1.2015

Section 5 - Specifications & CAD Drawings:

Integrated Metal Door Opening Systems

Sheet No - DE-HO-90-180

5.17

©2015, Total Door Systems

Page 106: Product Guide 6.1.2015

Section 5 - Specifications & CAD Drawings:

Integrated Metal Door Opening Systems

Sheet No - DE-HO-180-90

5.18

©2015, Total Door Systems

Page 107: Product Guide 6.1.2015
Page 108: Product Guide 6.1.2015
Page 109: Product Guide 6.1.2015

Section 5 - Specifications & CAD Drawings:

Section 081700 - Integrated Metal Door Opening Systems

Elevator Shaft Application: Part 1: General1.01 GENERAL NOTE A. The General Conditions, Supplementary General Conditions, and Division 1 - General Requirements are hereby made a part of this Section as fully as if repeated herein.

1.02 SUMMARY A. Section Includes

1. Integrated metal door opening assemblies with doors, operating hardware, accessories, and installation for a complete assembly.

1.03 RELATED SECTIONS A. Section 01 33 00, Submittal Procedures.

B. Section 01 25 13, Product Substitution Procedures.

1.04 REFERENCES A. ANSI/BHMA A156.3 – Exit Devices, American National Standards Institute/ Building Hardware Manufacturers Association, 2001.

B. ANSI/BHMA A156.4 – Closers, American National Standards Institute/ Building Hardware Manufacturers Association, 2000.

C. ANSI/BHMA A156.13 – Mortise Locks/Latches, American National Standards Institute/ Building Hardware Manufacturers Association, 2002.

D. ANSI/BHMA A156.26 – Continuous Hinges, American National Standards Institute/ Building Hardware Manufacturers Association, 2000.

E. ANSI/SDI - A250.8 Recommended Specifications for Standard Steel Doors and Frames, American National Standards Institute/Steel Door Institute, 2003.

F. ANSI/UL 10C -- Positive Pressure Fire Tests of Door Assemblies, American National Standards Institute/Underwriters Laboratories, 2001.

G. ASTM A1008 - Standard Specification for Steel, Sheet, Cold-Rolled, Carbon, Structural, High-Strength Low-Alloy and High-Strength Low-Alloy with Improved Formability, American Society of Testing and Materials; 2004a.

H. AWI AWQS - Architectural Woodwork Quality Standards P-208; The Architectural Woodwork Institute; 8th Edition.

I. NFPA 101 – Life Safety Code, National Fire Protection Association, 2003.

J. NFPA 252 - Standard Methods of Fire Tests of Door Assemblies, National Fire Protection Association, 2003.

K. SDI 111 A - Recommended Steel Door Frame Details, Steel Door Institute; 2002.

L. SDI 112 - Zinc-Coated (Galvanized/Galvannealed) Standard Steel Doors and Frames, Steel Door Institute, 1997.

M. UL 305 - Standard for Panic Hardware, Underwriters Laboratories Inc., 1997

N. UL 1784 - Air Leakage Tests of Door Assemblies, Underwriters Laboratories Inc., 2001

1.05 SYSTEM DESCRIPTION A. Performance Requirements

1. Integrated metal door opening assemblies: Exceed minimum performance standards.

a. Steel Doors: In accordance with ANSI/SDI A250.8, Grade 1, but not less than 5,000,000 cycles.

b. Exit Devices: In accordance with ANSI/BHMA A156.3, Grade 1, but not less than 5,000,000 cycles.

c. Closers: In accordance with ANSI/BHMA A156.4, Grade 1.

d. Mortise Locks/Latches: In accordance with ANSI/ BHMA A156.13, Grade 1, but not lessnthan 5,000,000 cycles.

e. Full-height Hinges: In accordance with ANSI/ BHMA A156.26, Grade 1, but not less than 5,000,000 cycles.

5.19

Page 110: Product Guide 6.1.2015

Section 5 - Specifications & CAD Drawings:

Section 081700 - Integrated Metal Door Opening Systems

Elevator Shaft Application Part 1: General (cont.)

1.06 SUBMITTALS A. Shop Drawings

1. In accordance with Section 01 33 00. 2. Indicate each door and frame condition; frame type, profile and installation detail; items of finish hardware, finishes and electrical roughin requirements.

B. Samples

1. In accordance with Section 01 33 00.

1.07 QUALITY ASSURANCE A. Qualifications

1. Manufacturer: Firm with not less than 5 years successful experience in fabrication of integrated metal door opening assemblies with full-height latch/lock and full-height hinge. 2. Supplier: Authorized distributor of manufacturer. 3. Installer: Manufacturer certified.

B. Regulatory Requirements

1. Rated door assemblies shall have been tested to meet conditions of NFPA 252 as required by NFPA 101 section 6-2.3.3 and UL 1784.

1.08 DELIVERY, STORAGE AND HANDLING A. Packaging: Polyvinyl wrapped, palette by floor, and clearly marked for each opening.

B. Delivery: Deliver to site in original unopened containers and pallets bearing system manufacturers name, and brand.

C. Store: Horizontally on level surface, not less than 2 inches off floor in a clean, dry well-ventilated area protected from sunlight, extreme heat, dryness and moisture.

D. Receiving, off loading, and site distribution should be handled by an authorized Total Door Distributor unless otherwise stipulated by contract. If the G.C. or other entity handles all or any portion of the receiving, off loading, and site distribution, they are held responsible for any and all damages that may result from potential miss handling of the product.

1.09 PROJECT CONDITIONS A. Do not bring door systems to site until building temperature and humidity ranges are compatible with recommended values for preservation of wood moisture content as listed by AWI AWQS. Building shall be stabilized at 30 to 60 percent humidity.

1.10 WARRANTY A. Integrated metal door opening assembly: Manufacturer’s standard 2 year warranty against defects in material and workmanship.

B. Locksets, hanger rods, and panic exit devices: Manufacturer’s lifetime limited warranty against defects in material and workmanship.

C. Store doors in a clear, dry ventilated space having controlled temperature and a relative humidity range between 30 and 60 percent. Stack doors flat and off the floor to prevent warpage.

5.20

Page 111: Product Guide 6.1.2015

Section 5 - Specifications & CAD Drawings:

Section 081700 - Integrated Metal Door Opening Systems

Elevator Shaft Application: Part 2: Products2.01 MANUFACTURERS A. Integratedmetaldoorsystems

1. TotalDoor:www.totaldoor.com 2. Substitutions:RefertoSection012513,Notpermitted.

B. Hardware

1. TotalDoor:www.totaldoor.com 2. Substitutions:RefertoSection012513,Notpermitted.

2.02 MATERIALS A. Frames

1. Tobesuppliedbyothers. 2. InaccordancewithANSI/SDIA250.8,SDI111A,andSDI112. 3. Construction:All-weldedunit,type. 4. Material:Steel,coldrolled,ASTMA1008,16gauge. 5. FireResistanceRating:WhereindicatedinContractDocumentsfordoors. 6. SpreaderBar:Removable,atsill.

B. FrameAnchorageDevices

1. Tosecurelyfastentowallconstructionwithoutdistortionorstress. 2. InaccordancewithfireresistanceratingindicatedinContractDocuments.

C. DoorSystems

1. InaccordancewithANSI/SDIA250.8.

2. GeneralUse–Interior,Exterior&FireRated

a. Stiles:Steel,galvannealed,16gauge,spotwelded. b. TopandBottomRails:5-1/2inch18gaugesteelrails. c. Cores: 1. Solidpolystyrenecontinuouslybondedtofaces. 2. TemperatureRise. d. Thickness:1-3/4inches. e. Faces:Steel,stretcherleveled,withoutseamsorspotwelds,galvannealed20gauge. f. Weldpattern:Enhancedinaccordancewithmanufacturesstandarddetails.

3. Gasketing

a. U.L.approvedforfiredoors. b. Jambs:Factoryappliedtolatch/lockingchannels. c. Floor:FactoryMortisedSweep

2.03 FINISHES A. HingeandLockingChannel

1. Finish:2partinfraredbakedpolyurethanepaint. a. ColortobeselectedbyArchitect.

B. DoorFaces,Interior

1. Finish:TobeselectedbyArchitect,refertodoorschedule.

2.04 FABRICATION A. UnlessmodifiedbyContractDocuments,constructintegratedmetaldooropeningassembliesin accordancewithmanufacturer’spublishedspecificationsandapplicableCoderequirements.

B. Factoryassemblewithfull-heighthingesandlatching/lockingchannels,locksets,exitdevices, closers,litekits,glazing,kickplates,stretcherplates,andarmorplates.

5.21

Page 112: Product Guide 6.1.2015

Section 5 - Specifications & CAD Drawings:

Section 081700 - Integrated Metal Door Opening Systems

Elevator Shaft Application: Part 3: Execution3.01 EXAMINATION A. Field Conditions

1. Prior to commencing installation, examine parts of building structure, which are to receive door systems and component parts.

2. Report, in writing, conditions which would prevent proper execution or endanger permanency of the work to the Architect.

B. Field Dimensions

1. Where possible, verify frame tolerances before fabrication of door systems.

2. Notify Architect of variances with reviewed shop drawings.

C. Corrective measures, when necessary, shall be determined and approved prior to commencing fabrication.

D. Coordinate door opening assembly details with adjacent work to assure proper attachments, clean junctions, etc.

3.02 INSTALLATION A. Install work in accordance with Contract Documents and reviewed shop drawings.

1. Install door systems and hardware in accordance with manufacturer’s recommendations.

2. Deliver frames to be installed by others.

B. Frames

1. Set plumb and square in accordance with DHI standards.

a. Out-of-square at frame head: Not to exceed 1/16 inch. b. Out-of-plumb for each frame jamb: Not to exceed 1/16 inch. c. Out-of-alignment for each side in plan: Not to exceed 1/16 inch. d. Twist dimension: Not to exceed 1/16 inch.

2. Brace until adjacent wall is constructed.

3. Securely anchor to adjacent wall.

4. Furnish and install clips, fastenings, and anchorages and conceal unless otherwise noted.

C. Door Systems

1. Hang to maintain manufacturer’s installation tolerances.

2. Adjust to freely swing without binding, sticking, or sagging, and to eliminate excessive clearances.

D. Hardware: When installation is otherwise complete, adjust hardware for proper operation and function.

5.22

Page 113: Product Guide 6.1.2015

Section 5 - Specifications & CAD Drawings:

Section 081700 - Integrated Metal Door Opening Systems

Elevator Shaft Application: Part 4: System Schedule

Set 90° Single Hold Open

1 ea Full Height Hinges H- 13 Rigidized Color TBD Total Door

1 ea Full Height Latch Channel L- 11 Color TBD Total Door

1 ea Operating Pull M33 628 Total Door

1 ea Operating Push M52 628 Total Door

1 ea Closer TDC96P Alum Total Door

1 ea Mag Holder TBD

1 ea Mortised sweep Total Door

1 ea Positive Pressure label (confirm rating with door schedule) Total Door

Set 180° Single Hold Open

1 ea Full Height Hinges H- 13 Color TBD Total Door

1 ea Full Height Latch Channel L- 11 Color TBD Total Door

1 ea Operating Pull M33 628 Total Door

1 ea Operating Push M52 628 Total Door

1 ea Closer AFPKT-180 Alum Total Door

1 ea Mag Holder TBD

1 ea Mortised sweep Total Door

1 ea Positive Pressure label (confirm rating with door schedule) Total Door

Set 90° Pair Hold Open

2 ea Full Height Hinges H- 13 Rigidized Color TBD Total Door

2 ea Full Height Latch Channel L- 11 Color TBD Total Door

2 ea Operating Pull M33 628 Total Door

2 ea Operating Push M52 628 Total Door

2 ea Closer TDC96P Alum Total Door

2 ea Mag Holder TBD

2 ea Mortised sweep Total Door

2 ea Positive Pressure label (confirm rating with door schedule) Total Door

Set 180° Pair Hold Open

2 ea Full Height Hinges H- 13 Color TBD Total Door

2 ea Full Height Latch Channel L- 11 Color TBD Total Door

2 ea Operating Pull M33 628 Total Door

2 ea Operating Push M52 628 Total Door

2 ea Closer AFPKT-180 Alum Total Door

2 ea Mag Holder TBD

2 ea Mortised sweep Total Door

2 ea Positive Pressure label (confirm rating with door schedule) Total Door

5.23

Page 114: Product Guide 6.1.2015
Page 115: Product Guide 6.1.2015

Section 5 - Specifications & CAD Drawings:

Integrated Metal Door Opening Systems

Sheet No - ESS-HO-90-LR

5.24

©2015, Total Door Systems

Page 116: Product Guide 6.1.2015

Section 5 - Specifications & CAD Drawings:

Integrated Metal Door Opening Systems

Sheet No - ESS-HO-90-RR

5.25

©2015, Total Door Systems

Page 117: Product Guide 6.1.2015

Section 5 - Specifications & CAD Drawings:

Integrated Metal Door Opening Systems

Sheet No - ESS-HO-180-LR

5.26

©2015, Total Door Systems

Page 118: Product Guide 6.1.2015

Section 5 - Specifications & CAD Drawings:

Integrated Metal Door Opening Systems

Sheet No - ESS-HO-180-RR

5.27

©2015, Total Door Systems

Page 119: Product Guide 6.1.2015

Section 5 - Specifications & CAD Drawings:

Integrated Metal Door Opening Systems

Sheet No - ESS-HO-180-PR

5.28

©2015, Total Door Systems