AC axial fan sickle-shaped blades (S series) with guard grille for short nozzle Nominal data Type Motor M4D074-EI Phase 3~ 3~ Nominal voltage VAC 230 400 Wiring Δ Y Frequency Hz 50 50 Method of obtaining data fa fa Valid for approval/standard CE CE Speed (rpm) min -1 1450 1450 Power consumption W 135 135 Current draw A 0.76 0.44 Max. back pressure Pa 105 105 Max. back pressure inH2O 0.42 0.42 Min. ambient temperature °C -40 -40 Max. ambient temperature °C 40 40 Starting current A 3.0 1.7 ml = Max. load · me = Max. efficiency · fa = Free air · cs = Customer specification · ce = Customer equipment Subject to change Data according to ErP Directive Actual Req. 2015 01 Overall efficiency η es % 32.7 29.1 02 Measurement category A 03 Efficiency category Static 04 Efficiency grade N 43.6 40 05 Variable speed drive No Data obtained at optimum efficiency level. The ErP data is determined using a motor-impeller combination in a standardized measurement setup. 09 Power consumption P e kW 0.19 09 Air flow q v m³/h 2595 09 Pressure increase p fs Pa 91 10 Speed (rpm) n min -1 1415 11 Specific ratio * 1.00 * Specific ratio = 1 + p fs / 100 000 Pa LU-27622 Tel:+86(021)-50460183 www.ebmpapst.com ebm-papst Ventilator (Shanghai) Co.,Ltd. No.418, Hua Jing Road, Wai Gao Qiao Free Trade Zone, Pudong S4D400 (8317072919) 8317072919 Page 1 /5 Revision 00 Conseguilo en GM Electrónica: https://gmelectronica.com.ar Av. Rivadavia 2458, CABA 011 4953-0417 - [email protected]
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
AC axial fansickle-shaped blades (S series)
with guard grille for short nozzle
Nominal data
Type
Motor M4D074-EI
Phase 3~ 3~
Nominal voltage VAC 230 400
Wiring Δ Y
Frequency Hz 50 50
Method of obtaining data fa fa
Valid for approval/standard CE CE
Speed (rpm) min-1 1450 1450
Power consumption W 135 135
Current draw A 0.76 0.44
Max. back pressure Pa 105 105
Max. back pressure inH2O 0.42 0.42
Min. ambient temperature °C -40 -40
Max. ambient temperature °C 40 40
Starting current A 3.0 1.7ml = Max. load · me = Max. efficiency · fa = Free air · cs = Customer specification · ce = Customer equipmentSubject to change
Data according to ErP DirectiveActual Req. 2015
01 Overall efficiency ηes % 32.7 29.1
02 Measurement category A
03 Efficiency category Static
04 Efficiency grade N 43.6 40
05 Variable speed drive NoData obtained at optimum efficiency level.The ErP data is determined using a motor-impeller combination in a standardized measurement setup.
09 Power consumption Pe kW 0.19
09 Air flow qv m³/h 2595
09 Pressure increase pfs Pa 91
10 Speed (rpm) n min-1 1415
11 Specific ratio* 1.00* Specific ratio = 1 + pfs / 100 000 Pa LU-27622
Wired = Wiring · U = Power supply · f = Frequency · n = Speed (rpm) · Pe = Power consumption · I = Current draw · qv = Air flow · pfs = Pressure increase