Product Catalogue Edition 9
Product CatalogueEdition 9
Call your local branch for further details 0800 11 66 90www.realcold.co.nz
Realcold Welcomes You
Thank you for using the latest edition of our catalogue. We trust you will fi nd it quick and easy to use.
With new and innovative, market-driven products engineered for New Zealand conditions, the product range available from Realcold has been selected to provide your business with a true price and quality competitive advantage.
Our motivated sales and engineering team are always on hand to assist with queries, recommendations and solutions, and to share ideas.
Feel free to give us a call at any time to discuss your requirements!
Yours faithfully,
The Realcold Team
Auckland Branch / Support Office9 Prescott Street, Penrose 1061PO Box 12072, Penrose 1642Orders Direct Line: 0800 11 66 90Orders Direct Fax: 09 526 5748Phone: 09 526 5700Fax: 09 526 5721Email: [email protected]
Christchurch71 Harman Street, Addington, Christchurch 8024PO Box 9150, Tower Junction, Christchurch 8149Phone: 03 338 8084 Fax: 03 338 9938Email: [email protected]
Dunedin18 Roberts Street, Dunedin 9016PO Box 2536, Dunedin 9044Phone: 03 467 7106 Fax: 03 467 7107Email: [email protected]
Hamilton43 Lake Road, Frankton, Hamilton 3204PO Box 5238, Frankton, Hamilton 3242Phone: 07 848 2111 Fax: 07 848 2333Email: [email protected]
HastingsCnr St Aubyn Street East & Miller Street Hastings 4122PO Box 488, Hastings 4156Phone: 06 870 3714 Fax: 06 870 3726Email: [email protected]
North HarbourUnit C, 28 Canaveral Drive, Albany 0632PO Box 305354, Triton PlazaNorth Shore City 0757Phone: 09 477 0274 Fax: 09 478 2309Email: [email protected]
Palmerston NorthUnit 2, 597-599 Tremaine Avenue PO Box 4368, Manawatu Mail Centre Palmerston North 4442Phone: 06 357 9101 Fax: 06 357 9103Email: [email protected]
Tauranga5 Barberry Street, Judea, Tauranga 3110PO Box 15610, Tauranga 3144Phone: 07 571 0096 Fax: 07 571 0097Email: [email protected]
Wellington54 Fitzherbert Street, Petone, Lower Hutt 5012PO Box 38527, Wellington Mail Centre Lower Hutt 5045Phone: 04 569 3072 Fax: 04 568 2210Email: [email protected]
Whangarei Unit A1, 7 - 11 Nell Place, Raumanga Whangarei 0110PO Box 25056, Whangarei Mail CentreWhangarei 0148Phone: 09 430 4476 Fax: 09 430 7465Email: [email protected]
Branch Locations
Com
pres
sors
Ice
Mac
hine
sSy
stem
Com
pone
nts
Valv
esA
ir-C
ondi
tioni
ngC
onde
nsin
g U
nits
Hea
t Exc
hang
ers
Page 1 - 28
• Sealed Compressors• Scroll Compressors• Semi-Hermetic Compressors• Screw Compressors• Compressor Spares
Page 29 - 65
• Coolroom Selection Guide• Hermetic Condensing Units• Semi-Hermetic Cond Units• Outdoor Package Units• Unit Accessories
Page 66 - 87
• Heat Exchangers• Room Evaporators• Air Cooled Condensers• Evap Spares & Accessories
Page 88 - 90
• Cube Ice Machines• Flake Ice Machines• Ice Cube Dispensers• Industrial Ice Flakers• Industrial Flaker Packages
Page 126 - 134
• Suction Accumulators• Oil Separators• Oil Control Components• Liquid Receivers• Driers & Sight Glasses
Page 91 - 125
• Air-Conditioning Units• Air-Curtains• Pipe Trunking• Unit Mounting• Condensate Pumps
Page 135 - 149
• Regulating Valves• Expansion Valves• Reversing Valves• Solenoid Valves• Service Valves
Refer to www.realcold.co.nz/legal/terms-conditions.aspx for Realcold terms & conditions, freight & returns policies.
Compressors
Ice Machines
System Components
Valves
Air-Conditioning
Condensing Units
Heat Exchangers
Tube
& F
ittin
gsC
hem
ical
sTo
ols
& Te
st E
quip
men
tC
ontr
ols
Har
dwar
eFa
n M
otor
s
Page 173 - 175
• Fastenings• Locksets • Hinges • Latches
Page 176 - 178
• Evaporator Fan Motors• Condenser Fan Motors• Fan Motor Assemblies• Air Cond Fan Decks• Fan Blades
Page 179 - 183
• Refrigerants• Compressor Oil• Vacuum Pump Oil• Service Aids• General Chemicals
Page 184 - 193
• Air Conditioning Controls• Electronic Thermostats• Mechanical Controls• Pressure Switches• Defrost Timers
Page 194 - 208
• Installation Tools• Vacuum Pumps• Reclaim Units• General Tools
Page 150 - 172
• Pair Coil• Copper & Pvc Tubing• Copper & Brass Fittings• Insulation• Pipe Supports
Refer to www.realcold.co.nz/legal/terms-conditions.aspx for Realcold terms & conditions, freight & returns policies.
Tube & Fittings
Chemicals
Tools & Test Equipment
Controls
Hardware
Fan Motors
Page 209 - 228
• Pipes• Fittings• Valves• Tools• Accessories
PP-R / PP-RCT Pipe Systems
PP-R
Pip
e Sy
stem
s
INDEXA - C
INDEXALPHABETICAL
A
Access Ports 161
Access Port Core Removers 197
Accumulators 126
Acid Test Kits 183
Actabs 183
Adhesive - Insulation 165
Air Conditioning
• MHI Hi-Wall Units 92 - 94
• MHI Floor Mount 95
• MHI SCM Multi Inverter Split System 96 - 97
• MHI Cassette Split System 98
• MHI FDUM-FDUA Static 99 - 100
• MHI Under Ceiling Split System 101
• Gree Window Wall 103
• Gree Cozy Hi-Wall 104
• Gree Hansol Hi-Wall 105
• Gree Floor Mounted Console 106
• Gree Air Curtains 107
• Accessories 108
• Mounting Brackets 109
• Aspen Condensate Pumps 110 - 113
• Aspen Pumps Spares 113
• Heat Pumps Accessories 113
• Electrical & Thermostats 114
• Ducting Accessories 115 - 116
• Ducting Grilles 117 - 119
• Ducting Neck Adapters 120
• In-line Fans 121 - 123
• Cool Breeze 124 - 125
Air Cooled Condensers
• Steelfort 85
B
Ball Valves 138
Benders - Tube 199
Big Blu Leak Reactant 183
Brackets - Air Conditioning 109
Brass Fittings 158 - 160
Brazing Alloy 208
Brazing Accessories 208
Brazing Equipment 207
Bullet Valves 161
Burn Out Driers - Suction Line Filter Driers 131
C
Cabinet Coolers 68 - 71
Capacitors 114
Capillary Tube 188
Check Valves 137 - 138
Charging Hoses 195
Charging Scale 204
Cleaners & Disinfectant 181 - 182
Coil Cleaners 181
Coil Protectant 183
Cool Room Selection Guide 29
Compressors
• Tecumseh Hermetic Reciprocating 1 - 4
• Tecumseh Comp. Spares & Accessories 5 - 10
• Supco Accessories 11
• Copeland Hermetic Scroll 12 - 16
• Copeland Compressor Accessories 17
• Frascold Semi-Hermetic 18 - 22
• Frascold Compressor Spares 23 - 24
• Frascold Semi-Hermetic Twin Screw 25 - 27
• Semi-Hermetic Screw Accessories 28
Condensate
• Pumps 110 - 113
• Drainage 171 - 172
• Pans 193
Condensers
• Air Cooled - HC 67 - 76
• Air Cooled - Guntner 77 - 80
Condensing Units
• Tecumseh Hermetic Reciprocating 30 - 34
• Easypack Hermetic 35 - 38
• Milk VAT (RMV) 39
• Realpack Hermetic 40 - 44
• Frascold - Semi Hermetic 45 - 52
• Frascold - Remote Semi Hermetic 53 - 62
• Condenser Accessories 63 - 65
Controls
• Air Conditioning 114
• Defrost 192
• Refrigeration 190
• Fan Speed 191
• Oil Pressure 186
• Pressure 184 - 185
Coolbreeze 124 - 125
Note: Compressor accessories and spares follow compressor units.
INDEXC - H
Coolroom Hardware 175
Copeland Compressors 12 - 17
Copper Fittings 154 - 157
Copper Directional Liquid Line Driers 131
Copper Tube 150 - 153
Cork Tape 165
Couplers
• Automotive 197
• Shrader 197
Crankcase Pressure Regulators 147
Cylinders
• Recovery 179, 202
• Refrigerant 179
Cylinder Adapters 159
D
Data Loggers 204
Deburring Tools 198
Defrost
• Controls & Timers 192
• Safety Thermostats 193
• Heat Tape 193
• Condensate Pans 193
Dektite Pipe Flashing 166
Dial Thermometers 203
Disinfectant 182
Domestic Thermostats 188
Door Hardware 175
Drain Pan Treatment 183
Drain Hose - Air Conditioning 150
Drain Pipe - PVC 171 - 172
Driers
• Sealed Type 130 - 132
• Cores & Shells 132 - 133
Dual Pressure Controls 184
Duct Tape 165
E
Easypack 35 - 38
EBM Fans 176 - 177
Electronic Controls
• Air Conditioning 114
• Refrigeration 190
Electronic Leak Detectors 204
Evaporators
• HC 67 - 76
• Guntner 77 - 80
• Steelfort 85
Evaporator Pressure Regulator Valves 147 - 148
Expansion Valves
• Sporlan 139 - 144
F
Fan Motors & Assemblies 176 - 177
Fan Blades 178
Fan Speed Controllers 191
Fastenings 173 - 174
Filter Driers
• Sealed Burnout 131
• Solid Core 132
Fin Combs 200
Fittings
• Brass 158 - 160
• Copper 154 - 157
• PVC / Drain 171
Flare Nuts 158
Flaring Tools 198
Flow Switches 186
Foam Tape 165
Frascold Compressors 18 - 28
Frascold Condensers 45 - 62
G
Gauge Manifolds 194
Gauge Hoses 195
Gauges 196
Gree Heat Pumps & Air Conditioners 102 - 107
Guntner Evaporators 77 - 80
H
Hand Shut Off Valves 136
Hardware 175
Heat Exchangers
• Doucette 66
• HC Evaporators 67 - 76
• Guntner Evaporators 77 - 80
• Realcold Evaporator Data 81 - 84
• Steelfort Air Cooled Condensers 85
• Bluemay Evaporator Mountings 86 - 87
INDEXALPHABETICAL
Note: Compressor accessories and spares follow compressor units.
INDEXH - R
INDEXALPHABETICAL
Note: Compressor accessories and spares follow compressor units.
Heat Seal Stick 208
Heat Trace Cable 193
Hinges & Locksets 175
Hoses
• Drainage (Air Conditioning) 150
• Charging 195
• Vacuum 195
• Hot Gas Bypass 148
HVAC Controls 114
HC Evaporators 67 - 76
I
Ice Machines 88 - 91
Ice Machine Cleaners 182
Insulation
• Pipe 163
• Sheet 164
• Tape 165
• Adhesive 165
J
Jointing Compounds 166
L
Latches, Locks & Strikes 175
Leak Detectors - Electronic 204
Leak Detectors - Liquid Reactant 183
Line Piercing / Tap Valves 161
Liquid Line Driers 131
Liquid Moisture Indicators 63, 134
Liquid Receivers Valves 138
Locksets & Hinges 175
Lubricants 180
M
Manifold Sets 194
Mapp Gas 207
Mastercool 194 - 204
Milk Vats (RMV) 39
MHI Heat Pumps & Air Conditioners 91 - 101
Mounting Brackets - Air Conditioning 109
Mounting Evaporators 87 - 88
Mounting Feet & Slabs - Air Conditioning 108
O
Oils 180
Oil Control Systems 127 - 128
Oil Filters 128
Oil Level Controls - Trax Oil 128
Oil Pressure Switches 23
Oil Separators 127
Oil Acid Test Kits 183
Outdoor Units - Realpacks 40 - 44
P
Pair Coil 150
Parker / Sporlan 139 - 149
Pipe & Tube Supports 167 - 170
Pipe Flashings - Dektite 166
Pipe Insulation 163
PP-R / PP-RCT
• Pipes 209 - 211
• Fittings 212 - 223
• Valves 224
• Tools & Accessories 225 - 228
Pressure Relief Valves 136
Pressure Controls 184 - 187
PVC Drainage / Pipe Ducting 171 - 172
R
Rack Systems 53 - 62
Ratchet Wrenches 198
Realpack 40 - 44
Receivers - Vertical Liquid 129
Recovery Cylinders 179, 202
Recovery Units 202
Refractometers 203
Refrigerant 179
Regulators
• Crankcase 147
• Evaporator Pressure 147 - 148
Relays - Solid State 11
RMV (Milk Vats) 39
Rotalock Valves 135
INDEXS - Z
INDEXALPHABETICAL
Note: Compressor accessories and spares follow compressor units.
S
Scales - Charging 204
Service Line Driers 152
Shrader Valves 161
Sealants 166, 170
Sight Glasses 64, 134
Silver Solder 208
Solenoid Valves 145 - 146
Sporlan / Parker 139 - 149
Steelfort Air Cooled Condensers 85
Suction Accumulators 126
Suction Line Filter Driers & Filter Driers 131
T
Tecumseh Compressors 1 - 10
Tecumseh Condensing Units 30 - 34
Tecumseh Semi Hermetic Unit - Realpack 40 - 44
Test Kits - Oil Acid 183
Test Equipment - Meters 203
Thermometers
• Dial 203
• Handheld 203
Thermostatic Expansion Valves 141 - 144
Thermostats
• Domestic Fridge 188
• Commercial Fridge 188
• Air Conditioning 114, 189
Temperature Sensors 191
Time Clocks 192
Tools Section 198 - 200
Toyo 108, 150
Tube - Copper 151 - 153
Tube Cutters / Benders 198 - 199
Tube Expanders 198
Tube & Pipe Supports 167 - 170
TX Valves 141 - 144
V
Vacuum Gauge Electronic 204
Vacuum Hoses 195
Vacuum Pumps 201
Vacuum Pump Oil 180
Valve Core Removers 197
Valves
• Rotalock 135
• Hand Shut Off 136
• Pressure Relief 136
• Reversing 137
• Check 137 - 138
• Liquid Receiver 138
• Ball 138
• Expansion 139 - 144
• Solenoid 145 - 146
• Crank Pressure Regulator 147
• Evaporator Pressure Regulator 147 - 148
• Hot Gas Bypass 148
• CO2 149
• Access 161
• Line Piercing - Bullet 161
• Shrader 161
Vibration Eliminators / Pad 162
W
Waffle Pad 162
Wall Mounting Brackets - Air Conditioning 109
Welding & Brazing Equipment 207
Y
Yellow Jacket Spares 205 - 206
1Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Com
pres
sors
Tecumseh Europe Rating Conditions EN 12900Domestic Application LBP HBP / MHBP AC
T˚ evaporating -25˚C -35˚C -10˚C +5˚C
T˚ condensing +55˚C +40˚C +45˚C +50˚C
T˚ return gas (=evaporator outlet) +32˚C +20˚C +20˚C +10˚C
Sub-cooling 0˚K 0˚K 0˚K 0˚K
Note: Visit www.tecumseh-europe.com for additional product information.
T/FH
FH
RK
CAJ
TAGD*Dual Compressor
Terminology
LT (LBP) Low Temperature - Evaporating Temp Range -40˚C / -10˚C
HT (HBP) High Temperature - Evaporating Temp Range -15˚C / +15˚C
HT W (M/HBP) High Temperature Wide Range - Evaporating Temp Range -25˚C / +15˚C
AC Air Conditioning - Evaporating Temp Range -10˚C / +10˚C
S/F Static Cooled/Fan Cooled
F Fan Cooled
SOC Static with oil cooler
CAP Capillary Controlled
CAP/TEV Capillary or Expansion Valve Controlled
For suitable compressor oils, please see Lubricants Section on page 180.
M Mineral Oil
AB Alkylbenzene Oil
P Polyolester Oil
Warranty: See Warranty section at rear of catalogue for more details.
COMPRESSORSTECUMSEH HERMETIC RECIPROCATING
Nomenclature For Compressor And Condenser Titles
220 - 240 / 1 / 50 Voltage Hertz Phase
Tecumseh Sealed - Introduction L’Unite Hermetique is 100% owned by Tecumseh.
Where applicable all L’Unite compressors come complete with full electrics and rotalock valves included in cost. FH - TFH - TAG & *TAGD compressors come complete with crankcase heaters and oil level sight glasses. NB. A/C compressors may not have accessories attached.
EN 12900: The compressors rating conditions for refrigeration. The standard defines the new capacity rating points for refrigeration in a way which is more useful to refrigeration engineers. In addition, they specify the tolerances which are applicable to the characteristics of each product.
2Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Com
pres
sors
Tecumseh R134a Medium Temp Domestic-Commercial (220-240/1/50)RealcoldStock No.
Model Nom. Hp
Appl. Watts H (mm)
D (cm3)
OC (L) C Control Price$ Excl. GST
-15°C -10°C -5°C 0°C +7.2°C +10°C +15°C
C0511 THB4415YFZ 1/8 HT 161 198 245 302 400 443 524 186 4.23 0.250 S Cap/ TEV
C0512 THB4419YFZ 1/6 HT 194 241 299 368 484 534 629 169 5.0 0.27 S Cap/ TEV
C0518-AE2 AE4425Y 1/5 HT 241 323 417 524 698 770 907 186 7.6 0.250 F Cap/ TEV
C0525-AE2 AEZ4430Y 1/4 HT 319 407 516 643 854 945 1117 199 8.8 0.350 F Cap/ TEV
C0535-AE2 CAE4440Y 1/3 HT 403 524 670 842 1127 1249 1481 199 12 0.350 F Cap/ TEV
C0536-AE2 CAE4448Y 3/8 HT 524 659 828 1028 1365 1511 1787 212 14.2 0.350 F Cap/ TEV
C0537-AE2 CAE4456Y 3/7 HT 596 750 940 1162 1543 1694 1996 212 16.2 0.350 F Cap/ TEV
C0550 CAJ4461Y 1/2 HT 603 793 1021 1294 1780 2003 2453 258 18.3 0.887 F Cap/ TEV
C0575 CAJ4492Y 3/4 HT 800 1113 1467 1871 2554 2856 3454 271 25.9 0.887 F Cap/ TEV
C0590 CAJ4511Y 1 HT 1109 1474 1895 2382 3218 3592 4332 282 32.7 0.89 F Cap/ TEV
C0593* FH4518Y 1.1/2 HT 1348 2049 2831 3688 5039 5596 6629 330 53.2 1.480 F Cap/ TEV
C0595* FH4525Y 2 HT 2167 2913 3822 4884 6654 7411 8846 354 74.25 1.480 F Cap/ TEV
* C0593 and *C0595 are available both single and three phase - please state when ordering. Includes crankcase heater.
COMPRESSORSTECUMSEH HERMETIC RECIPROCATING
Tecumseh R134a Low Temp Domestic-Commercial (220-240/1/50)Column Key: D = Displacement, OC = Oil Charge, Control = Cap/TEV for all models listed.
RealcoldStock No.
Model Nom. Hp
Appl. Capacity (w) @ 32° Ambient H (mm)
D (cm3)
OC (L) C Control Price$ Excl. GST
-35°C -30°C -23.3°C -20°C -15°C -10°C
C0508 THB1365Y 1/5 LT 57 81 124 149 193 244 172 5.9 0.270 S Cap
C0522 AEZ2380Y 1/4 LT 75 116 180 215 2372 336 199 9.4 0.350 SOC Cap/ TEV
C0530 CAE2410Y 1/3 LT 73 121 208 261 351 456 199 12 0.250 F Cap/ TEV
C0534 CAE2412Y 3/8 LT 77 139 246 308 414 534 199 14.2 0.250 F Cap/ TEV
Tecumseh R134a Medium Temp Commercial (400/3/50)RealcoldStock No.
Model Nom. Hp
Appl. Watts H (mm)
D (cm3)
OC (L) C Control Price$ Excl. GST
-15°C -10°C -5°C 0°C +7.2°C +10°C +15°C
C0594* TFH4518Y 1.1/2 HT 1348 2049 2831 3688 5039 5596 6629 330 53.2 1.480 F Cap/ TEV
C0596* TFH4525Y 2 HT 2167 2913 3822 4884 6654 7411 8846 354 74.25 1.480 F Cap/ TEV
* C0594 and *C0596 are available both single and three phase - please state when ordering. Includes crankcase heater.
All above compressors use Polyolester oil.
Specified compressor heights are indicative of series dimensions. Certain model heights vary from specification. Please consult Realcold if the compressor height is crucial. For detailed dimensions refer to the Tecumseh General Catalogue, or visit: www.tecumseh-europe.com for additional product information.
3Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Com
pres
sors
Tecumseh R404A Medium Temp Domestic-Commercial (220-240/1/50)Column Key: D = Displacement, OC = Oil Charge, Control = Cap/TEV for all models listed.
RealcoldStock No.
Model Nom. Hp
Appl. Watts H (mm)
Displ. (cm3)
OC (L) Price$ Excl. GST
-15°C -10°C -5°C 0°C +7.2°C +10°C +15°C
C7012-AE2 AEZ4430Z 1/4 HT 343 431 532 644 818 889 1017 186 5.7 0.250
C7014-AE2 AEZ4440Z 1/3 HTW 470 583 716 865 1105 1203 1383 199 7.6 0.350
C7016-AE2 AE4450Z 3/7 HTW 504 652 823 1020 1358 1508 1806 212 9.40 0.350
C7020-AE2 CAE9460Z 1/2 HTW 667 1052 1288 1689 1866 2215 2515 212 11.3 0.350
C7021 CAE9470Z 1/2 HTW 803 1246 1520 1988 2605 2195 2605 215 13.3 0.350
C7030 CAJ9510Z 1 HTW 1167 1796 2182 2838 3704 3129 3704 282 18.3 0.887
C7036 CAJ4517Z 1.1/4 HT 1606 2058 2566 3138 4098 4520 5350 282 25.95 0.887
C7038 CAJ4519Z 1.1/2 HT 2120 2664 3276 3967 5125 5633 6632 282 34.45 0.887
*C7040 FH4524Z 2 HT 2299 3048 3889 4833 6388 7059 8359 354 43.5 1.480
*C7042 FH4531Z 2.1/2 HT 3055 3968 4991 6143 8070 8916 10580 370 56.65 1.480
COMPRESSORSTECUMSEH HERMETIC RECIPROCATING
Tecumseh R404A Medium Temp Commercial (400/3/50)Column Key: D = Displacement, OC = Oil Charge, Control = Cap/TEV for all models listed.
RealcoldStock No.
Model Nom. Hp
Appl. Watts H (mm)
Displ. (cm3)
OC (L) Price$ Excl. GST
-15°C -10°C -5°C 0°C +7.2°C +10°C +15°C
*C7058 TFH4540Z 3 HT 4043 5173 6437 7861 10245 11292 13349 370 74.25 1.480
*C7070P^ TAG4553Z 4.1/2 HT 4633 6220 8062 10202 13895 15550 18845 381 100.7 1.96
*C7074P^ TAG4561Z 5.0 HT 5389 7107 9082 11363 15282 17036 20527 381 112.5 1.96
*C7064P^ TAGP4546Z 4.0 HT 4035 5457 7122 9061 12401 13892 16850 368 90.2 1.960
*C7082P^ TAG4573Z 6.1/4 HT 7121 9156 11508 14224 18870 20938 25033 393 134.8 1.96
* Available both single and three phase - please state when ordering.P^ Include an oil level sight glass and connections for oil and pressure equalising lines.
All above compressors use Polyolester oil.
4Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Com
pres
sors
Tecumseh R404A Low Temp Commercial (220-240/1/50)Column Key: D = Displacement, OC = Oil Charge, Control = Cap/TEV for all models listed.
RealcoldStock No.
Model Nom. Hp
Appl. Watts H (mm)
Displ. (cm3)
OC (L) Price$ Excl. GST
-35°C -30°C -23.3°C -20°C -15°C -10°C
C0532-AE2 AE2415Z 3/8 LT 185 254 369 436 551 685 199 8.1 0.350
C0551 CAE2420Z 1/2 LT 312 414 581 677 838 1081 212 12.54 0.350
C0554 CAE2424Z 5/8 LT 313 432 634 754 963 1208 215 15 0.350
C0573 CAJ2432Z 3/4 LT 372 533 800 956 1226 1541 271 18.3 0.887
C0580 CAJ2446Z 1 LT 597 821 1186 1397 1759 2176 282 26.15 0.887
C0592 CAJ2464Z 1.1/2 LT 820 1108 1579 1850 2317 2855 282 34.45 0.887
*C0599 FH2480Z 2 LT 1125 1587 2303 2701 3364 4105 370 53.2 1.625
C0600 FH2511Z 3 LT 1477 2109 3155 3762 4807 6013 370 74.25 1.625
* C0599 is available both single and three phase - please state when ordering.
COMPRESSORSTECUMSEH HERMETIC RECIPROCATING
Tecumseh R22 Sealed Air Conditioning (220-240/1/50)Rated in Watts at +7.2°C SST/+54.5°C SCT, for capillary use only.
RealcoldStock No.
Model Watts H (mm) D (cm3) OT OC (L) C Price$ Excl. GST
C0124 AJ5515E 3652 271 25.95 M 0.89 F
C0126 AJ5518E 4589 282 32.7 M 0.89 F
C0127 AJ5519E 4702 282 34.45 M 0.89 F
C0129 FH5524F 5749 330 43.5 M 1.33 F
C0138 FH5527E 6522 330 49.1 M 1.33 F
Tecumseh R404A Low Temp Commercial (400/3/50)Column Key: D = Displacement, OC = Oil Charge, Control = Cap/TEV for all models listed.
RealcoldStock No.
Model Nom. Hp
Appl. Watts H (mm)
Displ. (cm3)
OC (L) Price$ Excl. GST
-35°C -30°C -23.3°C -20°C -15°C -10°C
*C7122P^ TFH2511Z 3.0 LT 1477 2109 3155 3762 4807 6013 370 74.25 1.625
*C7126P^ TAG2516Z 4.0 LT 2341 3149 4623 5512 7061 8851 381 112.5 1.96
*C7128P^ TAG2522Z 5.0 LT 3187 4127 5855 6903 8733 10853 393 134.8 1.96
* Include crankcase heater and oil sight glass. P^ Include an oil level sight glass and connections for oil and pressure equalising lines.
All above compressors use Polyolester Oil and require fan cooling. Use Acid-Away to solve burn-outRefer to Realcold Technical Department for Tandem Compressor packages up to 12HP. and acid build up situations.
5Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Com
pres
sors
Electrics - Medium Temperature R404ARealcoldStock No.
Compressor Relay Overload Capacitor Start Capacitor Run
C7010 AEZ4425Z C1043 MTRP0037-31 C1591 MRP63AMK-3240 C2000 50 uf/260V n/a
C7012 AEZ4430Z C1045 MTRP0027-31 C1504 MRP56AMK-3240 C2000 50 uf/260V n/a
C7012-AE2 AE4430Z-FZ1A C1225 RP4038 C1689 T14526-23 C2092 64-77uF / 330V n/a
C7013 AEZ4440Z C1049 MTRP0030-31 C1672 MST58AMN-3240 C2038 100 uf/260V n/a
C7014 AEZ9440Z C1153 3ARR3-T3AB3 C1535 MSP61AMK-3242 C2000 50 uf/260V C2005 7.5 uf/400V
C7014-AE2 AE4440Z-FZ1A C1226 RP4538 C1690 T1411-23 C2093 108-130uF / 330V n/a
C7015 AEZ4450Z C1027 9660-A467-158 C1587 MRT28AMK-3240 C2000 50 uf/260V n/a
C7016 CAE9450Z C1154 RVA4L3D C1670 MST36AMHD-3242 C2000 50 uf/260V C2005 7.5 uf/400V
C7016-AE2 AE4450Z-FZ1A C1227 RP4938 C1691 T1419-23 C2089 88-108uF / 250V n/a
C7020 CAE9460Z C1155 3ARR3-U10AA3 C1578 MST28AMK-3242 C2000 50 uf/260V C2005 7.5 uf/400V
C7020-AE2 AE4460Z-FZ1C C1228 RP5418 C1692 T8107-23 C2092 64-77uF / 330V n/a
C7021 CAE9470Z C1154 RVA4L3D C1667 MST22APK-3242 C2010 64 uf/260V C2050 15 uf/400V
C7022 CAJ9480Z C1210 3ARR3-U10AU3 C1581 MRT24ALK-3242 C2037 88 uf/330V C2050 15 uf/400V
C7030 CAJ9510Z n/a C1675 MST00ALKD-3241 C2039 100 uf/330V C2050 15 uf/400V
C7032 CAJ9513Z C1148 3ARR3T6AY3 C1651 MST18AIW-3242 C2030 88 uf/260V C2050 15 uf/400V
C7036 CAJ4517Z C1125 3ARR3 T6AV3 C1680 MST16AGZ-3242 C2039 100 uf/330V C2061 17.5 uf/400V
C7038 CAJ4519Z C1190 3ARR3 W10AS3 C1685 CST00AHSF-3038 C2038 100 uf/260V C2088 35 uf/400V
C7039 FH4522Z C1126 RVA4I3R Internal C2042 125 uf/330V C2085 30 uf/400V
C7040 FH4524Z C1148 3ARR3T6AY3 Internal C2039 100 uf/330V C2085 30 uf/400V
C7042 FH4531Z n/a Internal C2046 156 uf/330V C2088 35 uf/400V
COMPRESSORSTECUMSEH COMPRESSOR SPARES
Electrics - Low Temperature R404ARealcoldStock No.
Compressor Relay Overload Capacitor Start Capacitor Run
C0532 AEZ2415Z C1053 MTRP49-31 C1504 MRP56AMK-3240 C2000 50 uf/260V n/a
C0532-AE2 AE2415Z-FZ1A C1230 RP4018 C1694 T4111-23 C2091 72-88uF / 330V n/a
C0545 CAE2417Z C1156 3ARR3-U3AU3 C1504 MRP56AMK-3240 C2000 50 uf/260V C2005 7.5 uf/400V
C0551 CAE2420Z C1049 MTRP0030-31 C1578 MST28AMK-3242 C2010 64 uf/260V n/a
C0554 CAE2424Z C1156 3ARR3-U3AU3 C1578 MST28AMK-3242 C2010 64 uf/260V C2050 15 uf/400V
C0555 CAJ2428Z C1150 3ARR18A-101B C1630 MRT16APK-3242 C2037 88 uf/330V n/a
C0573 CAJ2432Z C1157 3ARR3-U10AD3 C1580 MRT20ALKD-3242 C2037 88 uf/330V C2050 15 uf/400V
C0580 CAJ2446Z C1140 3ARR3-U10AB3 C1580 MRT20ALKD-3242 C2037 88 uf/330V C2050 15 uf/400V
C0592 CAJ2464Z C1155 3ARR3-U10AA3 C1583 MRT00AJZ-3241 C2037 88 uf/330V C2060 20 uf/400V
C0599 FH2480Z C1128 RVA4Q3D Internal C2046 156 uf/330V C2070 25 uf/400V
6Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Com
pres
sors
COMPRESSORSTECUMSEH COMPRESSOR SPARES
Electrics - Medium / High Temperature R22RealcoldStock No.
Compressor Relay Overload Capacitor Start Capacitor Run
C0320 AEZ4425E C1043 MTRP0037-31 C1591 MRP63AMK-3240 C2000 50 uf/260V n/a
C0325 AEZ4430E C1080 9660-B467-138 C1504 MRP56AMK-3240 C2000 50 uf/260V n/a
C0333 AEZ4440E C1049 MTRP0030-31 C1672 MST58AMN-3240 C2038 100 uf/260V n/a
C0335 AEZ9440T C1153 3ARR3-T3AB3 C1535 MSP61AMK-3242 C2010 64 uf/260V C2005 7.5 uf/400V
C0339 CAE4450E C1049 MTRP0030-31 C1578 MST28AMK-3242 C2000 50 uf/260V n/a
C0340 CAE9450T C1154 RVA4L3D C1545 MRT36AMHD-3242 C2000 50 uf/260V C2005 7.5 uf/400V
C0351 CAE9460T C1154 RVA4L3D C1578 MST28AMK-3242 C2000 50 uf/260V C2005 7.5 uf/400V
C0360 CAJ9480T C1140 3ARR3-U10AB3 C1581 MRT24ALK-3242 C2039 100 uf/330V C2050 15 uf/400V
C0375 CAJ9510T C1140 3ARR3-U10AB3 C1580 MRT20ALKD-3242 C2039 100 uf/330V C2050 15 uf/400V
C0390 CAJ9513T C1155 3ARR3-U10AA3 C1585 MRT00AJK-3241 C2037 88 uf/330V C2050 15 uf/400V
C0392 CAJ4517E C1141 3ARR3K6AV3 C1620 MST00AHKE-3241 C2039 100 uf/330V C2060 20 uf/400V
C0393 FH4522F C1126 RVA4I3R Internal C2042 125 uf/330V C2085 30 uf/400V
C0394 CAH4524T C1148 3ARR3T6AY3 Internal C2042 125 uf/330V C2085 30 uf/400V
C0395 FH4524F C1126 RVA4I3R Internal C2039 100 uf/330V C2085 30 uf/400V
C0396 CAH4531E C1141 3ARR3K6AV3 Internal C2046 156 uf/330V C2088 35 uf/400V
C0397 FH4531F C1125 3ARR3 T6AV3 Internal C2046 156 uf/330V C2088 35 uf/400V
Electrics - Options R22 (c/w start kit)RealcoldStock No.
Compressor Relay Overload Capacitor Start Capacitor Run
C0110 AJ5510F C1190 3ARR3 W10AS3 C1640 MST 18AKN-3242 C2080 21 uf/330 V C2050 15 uf/400V
C0111 AJ5512E C1190 3ARR3 W10AS3 C1650 MRT 18AJN-3242 C2080 21 uf/330 V C2050 15 uf/400V
C0123 AJ5513E C1195 3ARR3K4AA3 C1651 MST18AIW-3242 C2080 21 uf/330 V C2060 20 uf/400V
C0124 AJ5515E C1200 3ARR3K6AV3 C1662 MRT 16AGZ-3242 C2080 21 uf/330 V C2060 20 uf/400V
C0126 AJ5518E C1190 3ARR3 W10AS3 C1663 CST16AHSF-3054 C2080 21 uf/330 V C2070 25 uf/400V
C0127 AJ5519E C1190 3ARR3 W10AS3 C1665 CST 00AHPH-3038 C2080 21 uf/330 V C2070 25 uf/400V
C0128 AH5524E C1025 3ARR3U3P2 Internal C2030 88 uf/260V C2088 35 uf/400V
7Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Com
pres
sors
COMPRESSORSTECUMSEH COMPRESSOR SPARES
Electrics - Options R22 (c/w PTC relay)RealcoldStock No.
Compressor Relay Overload Capacitor Start Capacitor Run
C0110 AJ5510F C1011 CTP9EAEQ C1640 MST 18AKN-3242 n/a C2050 15 uf/400V
C0111 AJ5512E C1011 CTP9EAEQ C1650 MRT 18AJN-3242 n/a C2050 15 uf/400V
C0123 AJ5513E C1011 CTP9EAEQ C1651 MST18AIW-3242 n/a C2060 20 uf/400V
C0124 AJ5515E C1011 CTP9EAEQ C1662 MRT 16AGZ-3242 n/a C2060 20 uf/400V
C0126 AJ5518E C1011 CTP9EAEQ C1663 CST16AHSF-3054 n/a C2070 25 uf/400V
C0127 AJ5519E C1011 CTP9EAEQ C1665 CST 00AHPH-3038 n/a C2070 25 uf/400V
C0128 AH5524E C1011 CTP9EAEQ Internal n/a C2088 35 uf/400V
Electrics - Medium / High Temperature R134aRealcoldStock No.
Compressor Relay Overload Capacitor Start Capacitor Run
C0504 AZ3414Y C1010 CTP MSDAI C1527 MRP390HZ-3007 n/a n/a
C0505 AZ4419Y C1012 MTRP-0140-31 C1527 MRP390HZ-3007 C2030 88 uf/260V n/a
C0525 AEZ4430Y C1080 9660-B467-138 C1543 MRP61AMK-3240 C2000 50 uf/260V n/a
C0525-AE2 AE4430Y-FZ1A C1224 RP4238 C1689 T14526-23 C2094 47-56uF / 250V n/a
C0535 CAE4440Y C1047 MTRP0012-31 C1523 MRP380AMK-3240 C2022 72 uf/260V n/a
C0535-AE2 AE4440Y-FZ1A C1229 RP4838 C1690 T1411-23 C2095 88-108uF / 330V n/a
C0536 CAE4448Y C1047 MTRP0012-31 C1560 MRP36AMHD-3240 C2010 64 uf/260V n/a
C0536-AE2 AE4450Y-FZ1C C1221 RP5038 C1686 T14119-23 C2089 88-108uF / 250V n/a
C0537 CAE4456Y C1049 MTRP0030-31 C1607 T0691-A0 C2010 64 uf/260V n/a
C0537-AE2 AE4456Y-FZ1C C1222 MTRP0030-31 C1687 MSP28APW-5587 C2090 64-77uF / 250V n/a
C0538 CAJ4452Y C1205 3ARR18A-44B C1582 MRT26ALKD-3242 C2010 64 uf/260V n/a
C0550 CAJ4461Y C1205 3ARR18A-44B C1581 MRT24ALK-3242 C2010 64 uf/260V n/a
C0575 CAJ4492Y C1160 3ARRA18A-98B C1616 MRT24AJN-3242 C2010 64 uf/260V n/a
C0590 CAJ4511Y C1155 3ARR3-U10AA3 C1585 MRT00AJK-3241 C2039 100 uf/330V C2050 15 uf/400V
C0593 FH4518Y C1190 3ARR3 W10AS3 Internal C2030 88 uf/260V C2070 25 uf/400V
C0595 FH4525Y C1125 3ARR3 T6AV3 Internal C2039 100 uf/330V C2085 30 uf/400V
8Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Com
pres
sors
COMPRESSORSTECUMSEH COMPRESSOR SPARES
Electrics - Low Temperature Compressors R134aRealcoldStock No.
Compressor Relay Overload Capacitor Start Capacitor Run
C0501 AZ1335Y C1010 CTP MSDAI C1601 MRP 419HZ-3240 n/a n/a
C0502 AZ1339Y C1010 CTP MSDAI C1601 MRP 419HZ-3240 n/a n/a
C0503 AEZ1358Y C1010 CTP MSDAI C1527 MRP390HZ-3007 n/a n/a
C0522 AEZ2380Y C1045 MTRP0027-31 C1505 MRP59AMHD-3240 C2000 50 uf/260V n/a
C0530 CAE2410Y C1045 MTRP0027-31 C1550 MRT39AMHD-3240 C2000 50 uf/260V n/a
C0534 CAE2412Y C1045 MTRP0027-31 C1550 MRT39AMHD-3240 C2000 50 uf/260V n/a
Electrics - High Temperature R12RealcoldStock No.
Compressor Relay Overload Capacitor Start Capacitor Run
C0015 AE6ZA7 C1030 9660-B467-111 C1523 MRP380AMK-3240 n/a n/a
C0018 AE5ZA9 C1040 9660-B467-125 C1523 MRP380AMK-3240 n/a n/a
C0028 CAE41ZF11 C1090 9660-B467-145 C1560 MRP36AMHD-3240 C2000 50 uf/260V n/a
C0036 CAE4440A C1100 9660-B467-149 C1556 MRP36AMK-3240 C2030 88 uf/260V n/a
C0040 CAJ4452A C1205 3ARR18A-44B C1582 MRT26ALKD-3242 C2010 64 uf/260V n/a
C0055 CAJ4461A C1205 3ARR18A-44B C1581 MRT24ALK-3242 C2010 64 uf/260V n/a
C0074 CAJ4492A C1160 3ARRA18A-98B C1616 MRT24AJN-3242 C2010 64 uf/260V n/a
C0100 CAJ4511A C1155 3ARR3-U10AA3 C1610 MST16 AHKE 3242 C2037 88 uf/330V C2050 15 uf/400V
C0017 AZ0387A C1010 CTP MSDAI C1508 MSP390HZ-3240 n/a n/a
C0020 AZ0411A C1010 CTP MSDAI C1508 MSP390HZ-3240 n/a n/a
9Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Com
pres
sors
COMPRESSORSTECUMSEH COMPRESSOR SPARES
Electrics - Low Temperature R12RealcoldStock No.
Compressor Relay Overload Capacitor Start Capacitor Run
C0010 AEZ1336A C1010 CTP MSDAI C1510 MRP 379HK-3240 n/a n/a
C0012 AEZ1343A C1010 CTP MSDAI C1523 MRP380AMK-3240 n/a n/a
C0019 AEZ1360A C1010 CTP MSDAI C1523 MRP380AMK-3240 n/a n/a
C0022 CAE4ZF11 C1080 9660-B467-138 C1591 MRP63AMK-3240 C2000 50 uf/260V n/a
C0024 AEZ1380A C1070 9660-B467-131 C1540 MRP304AMN-3240 n/a n/a
C0026 CAE2410A C1080 9660-B467-138 C1550 MRT39AMHD-3240 C2000 50 uf/260V n/a
C0037 CAE2412A C1100 9660-B467-149 C1550 MRT39AMHD-3240 C2030 88 uf/260V n/a
C0058 CAJ2T12 C1150 3ARR18A-101B C1605 T0155-C2 C2010 64 uf/260V n/a
C0060 AZ4414Y C1150 3ARR18A-101B C1630 MRT16APK-3242 C2037 88 uf/330V n/a
C0077 CAJ2446L C1140 3ARR3-U10AB3 C1580 MRT20ALKD-3242 C2037 88 uf/330V C2050 15 uf/400V
C0105 CAJ2464L C1155 3ARR3-U10AA3 C1583 MRT00AJZ-3241 C2037 88 uf/330V C2060 20 uf/400V
C0011 AZ1335A C1010 CTP MSDAI C1601 MRP 419HZ-3240 n/a n/a
C0014 AZ1340A C1010 CTP MSDAI C1601 MRP 419HZ-3240 n/a n/a
C0021 AEZ2380C C1080 9660-B467-138 C1506 MRP61AMGE-3240 C2010 64 uf/260V n/a
Crankcase Heaters RealcoldStock No.
Model Description Price$ Excl. GST
C1001 H-10154W 240 VoltSuitable for L’Unite AH and TAH compressorsSuitable for Kirby AH, AG and CL compressors
C1003 H-10260W 240 VoltSuitable for L’Unite AJ and CAJ compressorsSuitable for Kirby AJ compressors
C1005 Crankcase Heater to suit FH, TFH & TAG Series C1003
10Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Com
pres
sors
Rotalock Valves - Tecumseh ReceiversRealcoldStock No.
Connection (mm)) Tube SizeOD. (mm)
Price$ Excl. GST
C1922 19.1 6.3
C1923 19.1 9.5
C1908 23.5 6.3
C1909 23.5 9.5
Rotalock Valves - Tecumseh CompressorsRealcoldStock No.
Connection (mm)
Tube SizeOD. (mm)
Suits - Suction Suits - Discharge Price$ Excl. GST
C1911 23.5 12.7 CAJ2446Z CAJ4416Y CAJ4492Y CAJ9480Z
TFH4524Z TFH4540Z (T)FH2480Z FH2511Z FH4518Y FH4525Y (T)FH4513Z TFH2511Z
C1912 23.5 15.9CAJ2464Z CAJ4511Y CAJ4517Z CAJ4519Z CAJ9510Z CAJ9513Z
—
C1913 31.8 15.9(T)FH2480Z (T)FH2511Z FH4518Y (T)FH4524Z (T)FH4525Y
TAG2516Z TAG2522Z TAG4553Z TAG4561Z TAG4573Z
C1916 31.8 22.2 (T)FH4531Z TAG2516Z TAG4553Z TFH4540Z —
COMPRESSORSTECUMSEH ACCESSORIES
Maximum Torque Settings Nm (cm Kg)Valve SpindleSmall Valves 11.7 (115)19 mm square body 14 (138)22 mm square body 21 (207)28 mm square body 35 (344)
Valve cap on Rotalock¼” (7/16” thread) 14 (138)3/8” (5/8” thread) 30.5 (300)½” (3/4” thread) 45 (442)¾” (7/8” thread) 59 (580)
Rotalock valves on compressors and receivers (with joint)¾” thread 56.5 (553)1” thread 84.5 (829)1 ¼” thread 141 (1382)1 ½” thread 197 (1935)1 ¾” thread 317 (3110)
Connections on parallel mounted versions1 ¾” thread 107 (1050)5/8” thread 45 (442)
Sight Glass1 1/8” 51 (500)
11Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Com
pres
sors
COMPRESSORSSUPCO ACCESSORIES
Solid State Relays RealcoldStock No.
Model Description HP/Voltage Price$ Excl. GST
C4000 ICG 220 220V Solid State Relay 1/12 HP through 1/2 HP
C4005 PO 230 230V Solid State Relay 1/12 HP through 1/2 HP
C4020 RO-82 220V Relay & Overload 1/12, 1/10, 1/8 HP
C4015 RO-62 220V Relay & Overload 1/6, 1/5 HP
C4010 RO-42 220V Relay & Overload 1/4, 1/3 HP
C4030 RCO-820 230V 3 n' 1 Start Relay 1/12, 1/10, 1/8 HP
C4035 RCO-620 230V 3 n' 1 Start Relay 1/6, 1/5 HP
C4040 RCO-420 230V 3 n' 1 Start Relay 1/4, 1/3 HP
C4050 SPP-5 230V Starter Pow-R-Pak PSG A/C 4000-120000 BTU
C4062 APR-5 Universal Replacement Relay Pick up voltage 130V-370V
C4026 URSC-20 230V Relay Start Capacitor
Applications For Solid State Relays
ICG Series:• One size for all compressors 1/12 through 1/2 HP.• Will replace most current relays.• Can be used with or without start capacitor.
PO Series:• One size for all compressors 1/12 through 1/2 HP.• Replaces all push-on current type relays.• For use on compressors with “pin type” terminals.• Can be used on all capacitor and non-capacitor start motors.• Lowest resistance solid state relay.• Will restart a balanced system within one minute.
RO Series:• Relay and overload in one combination unit.• Pre-wired for fast, simple installation.• Superior locked rotor protection eliminates start winding overheating.• Replaces all hermetic compressor relay and overload units 1/12 through 1/3 HP.• Can be used in conjunction with a start capacitor.
RCO Series:• The 3 n’ 1 Start Relay replaces all three electrical components, Relay, Overload, and Start Capacitor, on all
capillary systems.• Completely pre-wired.• Installs quickly and easily, simply by pushing on 3 female pin terminals.
URSC Series:• One size for all compressors 1/12 through 1/2 HP both domestic and commercial.• A combined solid state starting relay and capacitor.• Completely pre-wired.• Replaces current type relays.• Provides added boost for hard start and unbalanced systems.• Prevents low voltage starting problems. (No additional wires required.)
RO
RSC
RCO
RO
ICG
PO
PR5
12Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Com
pres
sors
COMPRESSORSCOPELAND HERMETIC SCROLL™
Copeland Scroll™ Compressors - IntroductionCopeland Scroll™ Compressors are manufactured by Emerson Climate Technologies.
With its European Headquarters based in Germany and manufacturing plants all around Europe, Emerson Climate Technologies is the world’s largest provider of HVAC/R solutions, delivering simple answers for commercial, industrial, and residential applications.
Standard Copeland Scroll™ Compressor unit includes:
• Compressor filled with ester oil• Rotalock / Sweat connections• Oil sight glass• Schraeder connection for oil fill or drain• Rubber mountings• E-protection module on all compressors from 7.5 to 15hp
Features & Benefits
• Designed to meet the specific needs in refrigeration (medium and low temperature applications).• Wide range of operations (2 to 15hp for all R404A, R134S and R22 applications).• High efficiencies all year round (continuous scroll flank contact maintained by centrifugal force minimizing gas leakage,
maximising efficiency).• Capacity control (modulation range is continuous from 10 to 100%).• Compactness (Small footprint with reduced weight by up to 50% compared to standard semi-hermetic compressors).• Robustness and reliability (Stringent qualification tests ensure maximum reliability, Teflon coated bearings, fewer parts).• Compressor protection (All 2 to 6HP compressors are supplied with internal thermal protectors and all 7.5hp to 15hp models
feature an electronic module).• Smooth operation (Designed with a discharge check valve).• Asercom certified performance data (Compressor delivers performance defined and published by the manufacturer via
simulative data testing performed by experts and regular measurement at independent bodies.
ZB11MCE ZB92KCE ZB38KC ZB19KC ZBD45
Model Designation
ZB D 45 K C E - TFD - 551Application RangeZB = Med temp, high efficiencyZS = Med tempZF = Low tempZO = Low temp subcritical CO2ZR = Airconditioning R22ZP = Airconditioning 410a
Application OptionD = DigitalH = Horizontal
Capacity (BTU/hr) at 60 HzMultiply BTU/hr by 0.293 = Watts at 60 HzMultiply BTU/hr by 0.244 = Watts at 50 Hz
Bill of Material
Motor Version
Oil Type (E = POE; Blank = Mineral)
Model Variation IndexV = ZF-KVE with vapour injection, high efficiency
Capacity Multiplier K = 1000, M = 10000
13Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Com
pres
sors
Copeland Scroll™ - R22 Medium Temp Air Conditioning (220-240/1/50)Column Key: FIG = Picture #, D = Displacement, W = Weight for all models listed
RealcoldStock No.
Model Fig. Nom. Hp
Capacity (w) @ 45° Condensing Temp Displ. (m3/hr)
Weight (Kg)
Price$ Excl. GST
R22
- 15°C - 10°C -5°C 0°C + 5°C +7.2°C
CS0044 ZR28K3E-PFJ Fig 2 2.5 2880 3660 4530 5530 6650 7290 6.80 27
CS0047 ZR36K3E-PFJ Fig 2 3.0 3550 4430 5460 6620 7940 8690 8.60 29
CS0049A ZR42K3E-PFJ Fig 2 3.5 4190 5220 6410 7790 9370 10270 9.90 30
CS0050 ZR47K3E-PFJ Fig 3 4.0 5030 6320 7790 9470 11370 12435 11.0 31
CS0054 ZR68KCE-PFJ Fig 3 5.5 6720 8020 10210 12750 14160 15970 6.1 40
R410A Medium Temp Air Conditioning (380-420/3/50)RealcoldStock No.
Model Fig Nom. Hp
Capacity (w) @ 45° Condensing Temp Displ. (m3/hr)
Weight (Kg)
Price$ Excl. GST
R404A
-15°C -10°C -5°C 0°C +5°C +7.2°C
CS0220 ZP235KCE-TWD-522 Fig 5 20.0 25100 31300 38400 46600 53350 60100 36.30 140
CS0230 ZP385KCE-TWD-522 Fig 5 30.0 41600 51400 62800 76000 86850 97700 66.70 176
* A full range of R410A Scroll Compressors is available on indent
COMPRESSORSCOPELAND HERMETIC SCROLL™
Copeland Scroll™ - R22 Medium Temp Air Conditioning (380-420/3/50)Column Key: FIG = Picture #, D = Displacement, W = Weight for all models listed
RealcoldStock No.
Model Fig. Nom. Hp
Capacity (w) @ 45° Condensing Temp Displ. (m3/hr)
Weight (Kg)
Price$ Excl. GST
R22
- 15°C - 10°C -5°C 0°C + 5°C +7.2°C
CS0052 ZR61KCE-TFD Fig 3 5.0 5800 7420 9330 11500 13900 15200 14.4 36
CS0060 ZR68KCE-TFD Fig 3 5.5 6720 8020 10210 12750 14160 15970 16.2 39
CS0062 ZR72KCE-TFD Fig 3 6.0 7720 9610 11750 14160 16890 18425 17.06 39
CS0064 ZR81KCE-TFD Fig 3 6.5 84100 10530 13040 15890 19060 20775 18.75 39
CS0065 ZR94KCE-TFD Fig 4 8.0 9130 11480 14060 17000 20410 22395 22.12 57
CS0067 ZR108KCE-TFD Fig 4 9.0 11200 14080 17320 20970 25130 27505 24.87 60
CS0069 ZR125KCE-TFD Fig 4 10.0 12980 16320 20070 24300 29130 31880 29.08 61
CS0071 ZR144KCE-TFD Fig 4 12.0 14770 19020 23680 28890 34780 37630 33.20 61
14Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Com
pres
sors
Low Temperature Refrigeration R404A (380-420/3/50)RealcoldStock No.
Model Fig Nom. Hp
Capacity (w) @ 45° Condensing Temp Displ. (m3/hr)
Price$ Excl. GST
R404A
-25°C -20°C -15°C -10°C -5°C 0°C +7.2°C
CS0017 ZF18K4E-TFD Fig 6 6.0 5.14 6.39 7.89 9.66 11.75 14.15 18.25 17.06
CS0024 ZF33K4E-TWD Fig 7 10.0 8.75 10.90 13.45 16.50 20.10 24.30 31.30 28.78
CS0028 ZF40K4E-TWD Fig 8 13.0 10.85 13.45 16.55 20.20 24.60 29.70 38.30 35.55
CS0032 ZF48K4E-TWD Fig 8 15.0 13.10 16.35 20.20 24.80 30.10 36.20 46.30 42.76
Note: Duty ratings based on 45°C condensing temp & 2K sub-cooling.
COMPRESSORSCOPELAND HERMETIC SCROLL™
Medium Temperature Refrigeration R404A (380-420/1/50)RealcoldStock No.
Model Fig Nom. Hp
Capacity (w) @ 45° Condensing Temp Displ. (m3/hr)
Price$ Excl. GST
R404A
-25°C -20°C -15°C -10°C -5°C 0°C +7.2°C
CS0118 ZB30KCE-TFD Fig 9 4.0 3.19 4.07 5.12 6.37 7.84 9.56 13.85 11.68
CS0120 ZB38KCE-TFD Fig 9 5.0 4.01 5.09 6.38 7.91 9.72 11.85 15.40 14.37
CS0122 ZB45KCE-TFD Fig 9 6.0 4.73 6.00 7.51 9.31 11.45 13.90 18.05 17.06
CS0126 ZB58KQE-TFD Fig 10 8.0 5.25 7.42 9.75 12.35 15.25 18.60 24.10 22.12
CS0130 ZB76KQE-TFD Fig 11 10.0 8.12 10.55 13.35 16.55 20.30 24.70 31.90 28.82
CS0136 ZB92KCE-TWD Fig 1 13.0 9.00 12.30 16.00 20.10 24.90 30.30 39.10 35.55
CS0138 ZB11MCE-TWD Fig 1 15.0 12.45 15.50 19.15 23.40 28.40 34.20 43.50 42.76
Note: Duty ratings based on 45°C condensing temp & 2K sub-cooling.
Figure One Dimensions Model A +/- 3 (mm) C (mm) C1 (mm) D (mm) E (mm) F (mm) H (mm)
ZB92KCE 492 209 176 306 55 88 551
ZB11MCE 533 209 176 306 55 88 596
Note: Specified compressor heights are indicative of series dimensions. Certain model heights vary from specification. Please consult Realcold if the compressor height is crucial.
Figure One
15Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Com
pres
sors
Figure Two Dimensions Model H (mm) D (mm) S (mm)
ZR28K3E 383 357 264
ZR36K3E 406 380 283.5
ZR42K3E 419 393.8 296.3
Figure Three Dimensions Model H (mm) D (mm) S (mm)
ZR47K3E 436
ZR61KCE 476 429 316
ZR68KCE 476 429 316
ZR72KCE 476 429 316
ZR81KCE 462 433 316Figure Two Figure Three
Figure Four Dimensions Model H (mm) D (mm) S (mm)
ZR94KCE 495 463 113
ZR108KCE 552 520 141
ZR125KCE 552 520 141
ZR144KCE 552 520 141
Figure Five Dimensions Model H (mm) D (mm) S (mm)
ZP235KCE 713 685 352
ZP385KCE 716 678 394
Specified compressor heights are indicative of series dimensions. Certain model heights vary from specification. Please consult Realcold if the compressor height is crucial.
Figure Four Figure Five
Air Conditioning
COMPRESSORSCOPELAND HERMETIC SCROLL™
16Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Com
pres
sors
Figure Eight Figure Nine
Figure Six Figure Seven
Figure Ten Figure Eleven
Figure Six Dimensions Model A +/- 3
(mm)C +/- 3 (mm)
D (mm)
E (mm) F (mm) G (mm)
H (mm)
ZF18K4E 410 233 297 48 81 341 489
Figure Seven Dimensions Model A +/- 3
(mm)C (mm)
C1 (mm)
D (mm)
E (mm)
F (mm)
G (mm)
H (mm)
ZF24K4E 496 209 176 306 55 88 359 561
ZF33K4E 496 209 176 306 55 88 359 561
Figure Eight Dimensions Model A +/- 3
(mm)C (mm)
C1 (mm)
D (mm)
E (mm)
F (mm)
G (mm)
H (mm)
ZF40K4E 504 209 176 306 55 88 366 569
ZF48K4E 533 209 176 306 55 88 366 598
Figure Nine Dimensions Model A +/- 3
(mm)C (mm)
C1 (mm)
D (mm)
E (mm) F (mm) H (mm)
ZB30KCE 410 233 — 297 48 81 457
ZB38KCE 410 233 — 297 48 81 457
ZB45KCE 410 233 — 297 48 81 457
Figure Ten Dimensions Model H (mm) W (mm) L (mm)
ZB58KQE 477 284.2 263.6
Figure Eleven Dimensions Model H (mm) W (mm) L (mm)
ZB76KQE 546.1 284.2 263.6
Specified compressor heights are indicative of series dimensions. Certain model heights vary from specification. Please consult Realcold if the compressor height is crucial.
Refrigeration
COMPRESSORSCOPELAND HERMETIC SCROLL™
17Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Com
pres
sors
Copeland Scroll™ Compressors AccessoriesRealcoldStock No.
Description Price$ Excl. GST
CCS1000 Start Capacitor ZR68
CCS1001 Start Capacitor ZR28 - 47
CCS1002 Run Capacitor ZR68
CCS1003 Run Capacitor ZR28
CCS1004 Run Capacitor ZR42 - 47
CCS1005 Run Capacitor ZR36
CCS1006 C/Case Heater ZR84 -144, ZB58-76
CCS1007 C/Case Heater ZR22 - 81, ZB30-45
CCS1008 Crankcase Heater ZR16 - 19M
CCS1009 Suction Rotalock Seal
CCS1010 Suction Rotalock Seal
CCS1011 Potential Relay ZR68
CCS1012 Current Relay ZF
CCS1013 Potential Relay ZR28 - 42
CCS1014 Summit Temp T/Stat
CCS1017 Valve Kit ZB58
CCS1018 Valve Kit ZF18
CCS1019 Valve Kit ZF24
CCS1020 Valve Kit ZF33 - 40, ZB92
CCS1021 Valve Kit ZF48, ZB11
CCS1023 CC Heater ZF40 - 48, ZB92
CCS1024 Crankcase Heater ZP385
CCS1025 Crankcase Heater ZP235
COMPRESSORSCOPELAND HERMETIC SCROLL™
18Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Com
pres
sors
COMPRESSORSFRASCOLD SEMI-HERMETIC
STANDARD EQUIPMENT
The compressors are supplied with suction and discharge valves (sweat connections) rubber vibration absorbers, oil lubrication charge, nitrogen charge (1 bar) to protect compressor against humidity, oil sight glass and protection devices. V, Z and W series are equipped with oil pump and OPS1 Oil pressure protection switch. Compressors are coated with anti-rust protective primer and blue enamel coat.
PROTECTION DEVICES
For all compressors, protection is performed by means of a series of PTC thermistors placed into the stator windings of the electric motor and connected to a Kriwan INT69 electronic control module. V, Z and W series are supplied with discharge gas high temperature protec-tion composed of a PTC thermistor sensor also connected to the electronic control module. PTC thermistor sensor is supplied on request for Q and S series compressors.
LUBRICATION
For compressors of A, B, C, D, F, Q and S series, lubrication is carried out by centrifugation, with a special oil thrower disc. V, Z and W series compressors lubrication is performed by a high pressure oil pump and the
compressor includes oil filter and oil pressure connections with OPS1 Oil pressure protection switch.
FRASCOLD have earned their reputation as a leading world supplier and manufacturer of high quality semi-hermetic compressors which are ideally suited for todays conscientious environment. This has been achieved by using the latest technology, only the best materi-als available, combined with strict quality control and testing. When installing Frascold you can be assured of superior reliability, proven energy efficiency and long term trouble free operation.
Institutional presence withinASERCOM
ASERCOM Association of European Compressor & Controls Manufacturers
ASERCOM AIMCreation of standards for performance and safety, focusing on better Environment protection, servicing the refrigeration industry and its customers
PERFORMANCE DATAA Certified product guarantees a neutral valuation of its performance
FRASCOLD has more than 80 certified compressors
Frascold Compressors
19Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Com
pres
sors
COMPRESSORSFRASCOLD VSD INVERTERS
VARIABLE SPEED DRIVE INVERTER
Frascolds range of high quality VSD Inverters, which can be directly fitted to their A, B, D & Q-series compressors.
Three inverter sizes are avaialble to suit the following compressor models:2.2kw (Max 6.5A) A & B Series compressors4.0kw (Max 9.5A) D Series compressors7.5kw (Max 20A) Q Series compressors
• Integrated soft-start offers reduced compressor start up current• Less compressor starts reduces mechanical stresses and wear• Stable suction pressure - better control and less risk of liquid slug• Ideal for applications with multiple loads such as pubs & clubs• Improved energy efficiency resulting in reduced energy costs• Easy installation with simple direct mounting to compressor
Please contact Reacold’s technical department for further details.
Reduced Start-up Current Stable Suction Presure
Simple Connection
Power Supply 320 - 550V
Monitoring and command overide
via remote terminal
Optional Keyboard or PC Interface
20Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Com
pres
sors
COMPRESSORSFRASCOLD SEMI-HERMETIC
A & B Series
D Series
Q Series
S Series
A & B-Series - 2 Cylinder (240/1/50)
RealcoldStock No.
Model Nom Hp
DispM3/HR
R404A R134a R22 Price$ Excl. GST-25 -5 -5 -5
C5016 A1-6Y 1ph 1.0 5.5 1330 3250 1960 2980
C5033 A1.5-7Y 1ph 1.5 6.9 1680 4160 2570 3940
C5038 B1.5-9.1Y 1ph 1.5 8.9 2050 5160 3300 5190
C5044 B2-10.1Y 1ph 2.0 9.9 2340 5710 3800 5870
A, B & D-Series - 2 Cylinder (415/3/50)
RealcoldStock No.
Model Nom Hp
DispM3/HR
R404A R134a R22 Price$ Excl. GST-25 -5 -5 -5
C5018 A1-6Y 3ph 1.0 5.5 1330 3250 1960 2980
C5031 A1.5-7Y 3ph 1.5 6.9 1680 4160 2570 3940
C5036 B1.5-9.1Y 3ph 1.5 8.9 2050 5160 3300 5190
C5046 B2-10Y 3ph 2.0 9.9 2340 5710 3800 5870
C5048 D2-11.1Y 3ph 2.0 11.3 2710 6750 4100 6640
C5051 D2-13.1Y 3ph 2.0 13.2 3330 — 4890 —
C5061 D3-13.1Y 3ph 3.0 13.2 — 7940 4740 7920
C5063 D3-15.1Y 3ph 3.0 15.4 3990 9200 5580 8890
C5071 D3-18.1Y 3ph 3.0 17.9 4690 — 6770 —
C5078 D4-18.1Y 4.0 17.9 — 10880 6990 10850
Q & S-Series - 4 Cylinder (415/3/50)
RealcoldStock No.
Model Nom Hp
DispM3/HR
R404A R134a R22 Price$ Excl. GST-25 -5 -5 -5
C5072 Q4-20.1Y 4.0 19.8 4760 — 7230 —
C5099 Q5-21.1Y 5.0 21.2 — 12440 7330 12350
C5094 Q5.25.1Y 5.0 24.7 5970 14700 9610 14210
C5097 Q5-33.1Y 5.0 32.7 8380 — 11750 —
C5098 Q7-28.1Y 7.5 28.0 — 17140 9950 17080
C5102 Q7-33.1Y 7.5 32.7 — 19780 11900 19560
C5104 Q7-36.1Y 7.5 35.9 9970 — 14160 —
C5124 S7-33Y 7.5 32.7 8240 19780 11900 19560
C5106 S8-42Y 8.0 41.3 10820 — 16660 —
C5108 S12-42Y 12.0 41.3 — 24340 16560 23700
C5134 S10-52Y 10.0 51.5 13580 — 19190 —
C5138 S15-52Y 15.0 51.5 — 30920 18970 29360
C5142 S15-56Y 15.0 56.0 15080 — 21720 —
C5145 S20-56Y 20.0 56.0 — 35530 21760 33940
21Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Com
pres
sors
COMPRESSORSFRASCOLD SEMI-HERMETIC
V Series
Z Series
W Series
• Ratings at 45deg Condensing, European standard EN12900 / 20deg Suction gas temp / 0deg Subcooling• Please refer to Frascold selection software or contact Realcold for ratings at other conditions.• Compressors do not come with crank case heaters. Please order separately if required.
V Series - 4 Cylinder (415/3/50)
RealcoldStock No.
Model Nom Hp
DispM3/HR
R404A R134a R22 Price$ Excl. GST-25 -5 -5 -5
C5155 V15-59Y 15 58.5 15740 — 22890 —
C5160 V15-71Y 15 70.8 18540 — 27130 —
C5165 V20-59Y 20 58.5 — 35790 22980 35560
C5172 V20-84Y 20 83.8 20920 — 29850 —
C5185 V25-71Y 25 70.8 — 42950 26120 42120
C5186 V25-93Y 25 93.1 22020 — 34920 —
C5192 V30-84Y 30 83.8 — 51690 29980 51160
C5193 V32-93Y 32 93.1 — 55920 33040 55870
Z Series - 6 Cylinder (415/3/50)
RealcoldStock No.
Model Nom Hp
DispM3/HR
R404A R134a R22 Price$ Excl. GST-25 -5 -5 -5
C5190 Z25-106Y 25 106.2 26600 — 37170 —
C5198 Z30-126Y 30 125.7 30860 — 45710 —
C5200 Z35-106Y 35 106.2 — 65460 40150 64810
C5206 Z40-126Y 40 125.7 — 76480 47390 74590
C5210 Z40-154Y 40 154.4 41110 — 55260 —
C5215 Z50-154Y 50 154.4 — 93600 56560 91020
W Series - 8 Cylinder (415/3/50)
RealcoldStock No.
Model Nom Hp
DispM3/HR
R404A R134a R22 Price$ Excl. GST-25 -5 -5 -5
C5233 W50-187Y 50 186.1 44380 113570 67520 111300
C5234 W60-187Y 60 186.1 46480 115950 68620 111950
C5235 W60-206Y 60 205.8 51290 127370 77470 128300
C5238 W70-206Y 70 205.8 51150 126910 76290 126740
22Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Com
pres
sors
COMPRESSORSFRASCOLD SEMI-HERMETIC
Technical Data
RealcoldStock No.
Model Nom Hp
Amps (Dol) No of Cylind.
Disp. M3 / HR
Oil (Litres)
Footprint Valve Size Weight(kg)MRA LRA L (mm) W (mm) Disch
(Inch)Suction (Inch)
C5016 A1-6Y 1ph 1 6.2 23.6 2 5.5 1.2 234 194 1/2 5/8 36
C5018 A016Y 1 3.6 13.6 2 9.8 1.2 234 194 5/8 3/4 40
C5033 A1.5-7Y 1ph 1.5 7.9 35.8 2 6.9 1.2 234 194 1/2 5/8 36
C5038 B1.5-9.1Y 1ph 1.5 10.2 46.6 2 8.96 1 329 237 1/2 5/8 38
C5033A A157Y 1.5 4.5 20.6 2 6.9 1.2 234 195 1/2 5/8 36
C5036 B1.5-9.1Y 3ph 1.5 5.9 26.8 2 6.9 1 329 237 1/2 5/8 38
C5044 B2-10.1Y 1ph 2 11.7 62.5 2 9.8 1.2 234 194 5/8 3/4 40
C5046 B2-10Y 3ph 2 6.7 35.9 2 9.8 1.2 234 194 5/8 3/4 40
C5048 D2-11.1Y 3ph 2 7.1 35.9 2 11.3 1.2 234 194 5/8 7/8 45
C5051 D2-13.1Y 3ph 2 7.1 35.9 2 13.8 1.2 234 194 5/8 7/8 45
C5061 D3-13.1Y 3ph 3 8.8 43.7 2 13.8 1.2 234 194 5/8 1 1/8 49
C5063 D3-15.1Y 3ph 3 10 43.7 2 15.3 1.2 234 194 5/8 1 1/8 49
C5071 D3-18.1Y 3ph 3 10 43.7 2 17.9 1.2 234 194 5/8 1 1/8 49
C5078 D4-18.1Y 4 12.5 52 2 17.9 1.2 234 194 5/8 1 1/8 51
C5072 Q4-20.1Y 4 10.1 53.2 4 19.8 1.8 312 246 3/4 1 1/8 74
C5099 Q5-21.1Y 5 11.6 63.1 4 21.2 1.8 312 246 3/4 1 1/8 79
C5094 Q5.25.1Y 5 12.7 63.1 4 24.7 1.8 312 246 7/8 1 1/8 79
C5096 Q5-28.1Y 5 14 63.1 4 27.9 1.8 312 246 7/8 1 3/8 79
C5097 Q5-33.1Y 5 14.4 63.1 4 32.7 1.8 312 246 1 1/8 1 3/8 79
C5098 Q7-28.1Y 7.5 17.6 87.3 4 27.9 1.8 312 246 1 1/8 1 3/8 79
C5102 Q7-33.1Y 7.5 20 87.3 4 32.7 1.8 312 246 1 1/8 1 3/8 79
C5104 Q7-36.1Y 7.5 19.4 87.3 4 35.9 1.8 312 246 1 1/8 1 3/8 79
C5106 S8-42Y 8 20.3 90.3 4 41.3 1.8 292 266 1 1/8 1 3/8 117
C5108 S12-42Y 12 22.4 102.1 4 41.3 3.3 292 266 1 1/8 1 3/8 120
C5108 S12-42Y 15 22.4 102.29 4 41.32 2.9 550 405 1 1/8 1 3/8 120
C5138 S15-52Y 15 32.4 117.1 4 51.5 2.9 550 405 1 1/8 1 5/8 126
C5142 S15-56Y 15 30.7 117.1 4 56 3.3 292 266 1 1/8 1 5/8 130
C5155 V15-59Y 15 31.1 117.1 4 58.5 4.5 381 305 1 1/8 1 5/8 170
C5160 V15-71Y 15 32.2 117.1 4 70.8 4.5 381 305 1 1/8 1 5/8 170
C5145 S20-56Y 20 38.4 136.2 4 56 3.3 292 266 1 1/8 1 5/8 132
C5165 V20-59Y 20 35.3 136.2 4 58.5 4.5 381 305 1 1/8 1 5/8 174
C5172 V20-84Y 20 42.6 145.2 4 83.8 4.5 381 305 1 1/8 1 5/8 180
C5185 V25-71Y 25 43.5 202.7 4 70.8 4.5 381 305 1 3/8 2 1/8 184
C5186 V25-93Y 25 52.3 202.7 4 93.1 4.5 381 305 1 3/8 2 1/8 190
C5190 Z25-106Y 25 53.6 202.7 6 106.2 4.5 381 305 1 3/8 2 1/8 220
C5192 V30-84Y 30 49.2 186.2 4 83.8 4.5 381 305 1 3/8 2 1/8 187
C5198 Z30-126Y 30 55.7 186.2 6 125.7 7.5 381 305 1 3/8 2 1/8 229
C5193 V32-93Y 32 53.1 239.2 4 93.1 4.5 381 305 1 3/8 2 1/8 192
C5200 Z35-106Y 35 60.2 239.2 6 106.2 4.5 381 305 1 3/8 2 1/8 223
C5206 Z40-126Y 40 71.9 273 6 125.7 7.5 381 305 1 5/8 2 5/8 240
C5208 Z40-154Y 40 77.9 273 6 154.4 7.5 381 305 1 5/8 2 5/8 240
C5215 Z50-154Y 50 90.4 321.4 6 154.4 7.5 381 305 1 5/8 2 5/8 244
C5234 W60-187Y 60 103.5 455 8 186.1 8 458 305 1 5/8 3 1/8 315
C5238 W70-206Y 70 116.8 548 8 205.8 8 458 305 2 1/8 3 1/8 328
23Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Com
pres
sors
COMPRESSORSFRASCOLD SPARES
DELTA-PII
Crankcase Heaters
RealcoldStock No.
Frascold Item No.
Item Suits Series Price$ Excl. GST
R0553 T00CH13RIC 50w Crank Case Heater A, B & D
R0552 T00CH1RIC 70w Crank Case Heater F, Q, S & T
R0555 T00CH9RIC 150w Crank Case Heater V, Z & W
Motor Protection
RealcoldStock No.
Frascold Item No.
Item Suits Series Price$ Excl. GST
R0820 T00ECA01 Motor Protection INT69 A, B, D, F, Q, S
R0822 T00ECA11 Motor Protection INT69TM V, Z, W
Oil Spares
RealcoldStock No.
Frascold Item No.
Item Suits Series Price$ Excl. GST
R0825 T00EC1620 DELTA-PII Oil Pressure Safety Switch All models
R0726 T00SK210000 Oil Pump Assembly W W series
R0727 T00SK210100 Oil Pump Assembly V-Z V & Z series
R0735 T00SK190100 Oil Strainer Assembly All models
R0730 T00SK170100 Sightglass All models
Capacity Control - Unloader Head
RealcoldStock No.
Frascold Item No.
Item Suits Series Price$ Excl. GST
C5222 T00SK250150 Capacity Control Q (Coil Included) Q series
C5221 T00SK220100 Capacity Control S (Coil Included) S series
C5225 T00SK220200 Capacity Control V-Z-W (Coil Included) V, Z, W series
Start Unloader Head
RealcoldStock No.
Frascold Item No.
Item Suits Series Price$ Excl. GST
C5226 T00SK250150 Start Unloader Q (Coil Included) S Series
C5226A T00SK250100 Start Unloader S (Coil Included) S Series
C5227 T00SK250200 Start Unloader V-Z-W (Coil Included) V, Z, W Series
* Can be used in conjuction with PWS to significantly reduce compressor starting current.
Head Cooling Fans (240/1/50)
RealcoldStock No.
Frascold Item No.
Item Suits Series Price$ Excl. GST
C5805 SZ-FM1 Head Cooling Fan A-F 1Ph A, B, D & F
C5803 SZ-FM2S/001 Head Cooling Fan S 1Ph S Series
C5810 SZ-FM9 Head Cooling Fan Q 1Ph Q Series
C5804 SZ-FM2V/001 Head Cooling Fan V 1Ph V Series
C5806 SZ-FM3/001 Head Cooling Fan Z 1Ph Z Series
C5807 SZ-FM4/001 Head Cooling Fan Z 1Ph W Series
Please contact Realcold for information and availability of Frascold spares and accessories not listed
24Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Com
pres
sors
COMPRESSORSFRASCOLD SPARES
Spares Parts List
To Suit Gasket Kit Complete
Valve Plate Kit Complete
Valve Plate Gasket Service Valve Kits
Body Head Suction Discharge
A075Y, A157Y T00SK0200 T00SK12501 S1351031E S1411032 T00SK100120 T00SK100110A076Y, A016Y, A158Y, B159Y, B159.1Y T00SK0300 T00SK12502 S1451031E S1411032 T00SK100120 T00SK100110B210Y T00SK0300 T00SK14501 S1451031E S1411032 T00SK100130 T00SK100120B210.1Y T00SK0405 T00SK14505 S1461031 S1411032 T00SK100130 T00SK100120D211Y, D211.1Y, D215.1Y, D215 T00SK0500 T00SK24800 S2341031 S2451032 T00SK100330 T00SK100310Q521Y, Q521.1Y, Q519, Q519.1Y T00SK1230 T00SK24800 S2341031 S2451032 T00SK100520 T00SK100320Q528.1Y T00SK1230 T00SK24800 S2341031 S2451032 T00SK100530 T00SK100330Q728Y T00SK1220 T00SK24802 S2451031 S2451032 T00SK100530 T00SK100340Q728.1Y T00SK1230 T00SK24800 S2341031 S2451032 T00SK100530 T00SK100340D213Y, D213.1Y, T00SK0600 T00SK24801 S2451031 S2451032 T00SK100330 T00SK100310D313Y, D313.1Y, D318Y, D318.1Y T00SK0600 T00SK24802 S2451031 S2451032 T00SK100340 T00SK100310D315Y, D315.1Y T00SK0500 T00SK24803 S2341031 S2451032 T00SK100340 T00SK100310D418Y, D418.1Y T00SK0600 T00SK24802 S2451031 S2451032 T00SK100340 T00SK100320D416, D416.1Y T00SK0500 T00SK24803 S2341031 S2451032 T00SK100340 T00SK100320F416Y, F416.1Y T00SK0700 T00SK36200 S4321031A S3631032 T00SK100520 T00SK100320F519Y T00SK0800 T00SK26202 S4381031A S3631032 T00SK100520 T00SK100320Q519, Q519.1Y T00SK1230 T00SK24800 S2341031 S2451032 T00SK100520 T00SK100320*Q420 — TBA — — TBA —Q525Y, Q525.1Y T00SK1220 T00SK24801 S2451031 S2451032 T00SK100520 T00SK100330Q725.1Y T00SK1220 T00SK24802 S2451031 S2451032 T00SK100520 T00SK100330Q528Y T00SK1220 T00SK24801 S2451031 S2451032 T00SK100530 T00SK100330Q533.1Y, Q733.1Y T00SK1220 T00SK24802 S2451031 S2451032 T00SK100530 T00SK100340S533Y, S533.1Y T00SK1300 T00SK44900 S4321031A S3631032 T00SK100600 T00SK100520S733Y T00SK1300 T00SK36200 S4321031A S3631032 T00SK100600 T00SK100520*Q736.1Y — TBA — — TBA —S739Y T00SK1400 T00SK36201 S4381031A S3631032 T00SK100600 T00SK100520S1039Y T00SK1400 T00SK36202 S4381031A S3631032 T00SK100600 T00SK100520*Q842Y, Q1242Y — TBA — — TBA —S1051Y T00SK1500 T00SK36205 S4481031A S3631032 T00SK100600 T00SK100520S1551Y T00SK1600 T00SK36206 S4491031A S3631032 T00SK100640 T00SK100520S1556Y, S2056Y T00SK1700 T00SK44906 S4451031A S3631032 T00SK100640 T00SK100520V1559Y T00SK1800 T00SK49500 S6301031C S8701032 T00SK103700 T00SK100610V2059Y T00SK1800 T00SK49501 S6301031C S8701032 T00SK103700 T00SK100610V1571Y, Z25106 T00SK1900 T00SK49502 S6351031D S8701032 T00SK103700 T00SK100610V2571Y T00SK2000 T00SK49503 S635103D S8701032 T00SK103800 T00SK100600V2084Y T00SK2100 T00SK49504 S6401031C S8701032 T00SK103700 T00SK100610V3084Y T00SK2200 T00SK49505 S6401031C S8701032 T00SK103800 T00SK100600V2593Y T00SK2210 T00SK87003 S8601031B S8701032 T00SK103800 T00SK100600V3293Y T00SK2210 T00SK87004 S8601031B S8701032 T00SK103800 T00SK100600V25103Y T00SK2220 T00SK87005 TBA TBA T00SK103800 T00SK100600Z25106Y T00SK2400 T00SK49502 S6351031D S8701032 T00SK103800 T00SK103711Z35106Y T00SK2400 T00SK49503 S6351031D S8701032 T00SK103800 T00SK103711Z30126Y T00SK2500 T00SK49504 S6401031C S8701032 T00SK103800 T00SK103711Z40126Y T00SK2500 T00SK49505 S6401031C S8710032 T00SK103810 T00SK103701Z40154Y T00SK2600 T00SK65005 S6510131D S8701032 T00SK103810 T00SK103700Z50154 T00SK2600 T00SK65006 S6501031D S8701032 T00SK103810 T00SK103700W60187Y T00SK2900 T00SK87004 S8601031B S8701032 T00SK103910 T00SK103700W70206Y T00SK3000 T00SK65006 S6501031D S8701032 T00SK103910 T00SK103720
* Please discuss with your Realcold branch.
25Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Com
pres
sors
COMPRESSORSFRASCOLD TWIN SCREW
FRASCOLD Twin screw compressors are available in three ranges. Each range is spe-cifically designed to provide superior performance for their nominated application and temperature range. Coupled with optimised motors, state of the art compressor protection and long life, extra heavy duty bearings, all models provide high energy efficiency, unsurpassed performance and long-term reliability where a low noise, high capacity solution is required.
Frascold Screw Compressors
Included with Compressor:• Capacity control device• Suction service valve with solder sleeve• Discharge service valve with check valve• Integral electronic protection, includes:
• Sensor for maximum discharge temperature• Sensor for maximum temperature of electric motor• KRIWAN Electronic module
Not Included With Compressor:• Vibration absorbers• Components for external oil piping, includes:
• Oil strainer assembly with core• Solenoid valve with coil and plug• Electronic module for oil flow switch • Oil flow switch• Oil sight glass
Standard Equipment
FEATURESScrew Profiles
The compressors are two-shaft rotary displacement design, with innovative profiles of the screws (Ratio 5:6 between male & female screw). The shafts are fitted with large roller bearings sized to bear both radial and axial loads, resulting in reduction of friction, vibration and lower noise levels. Discharge check valve, located in the service valve prevents counter rotation when compressor stops operating.
High Efficiency Electric Motor
Electric motor is two-pole, three phase asynchronous type. The rotor is fitted to the shaft of the male screw. Cooling of the motor is carried out by the suction gas flowing through slots in the rotor, also causing any liquid refrigerant to be separated due to the centrifugal action. Power Supply: 400/3/50 Connection: Part Winding Start (PWS) 50% + 50% current distribution
Capacity Control
All compressors are fitted with capacity control, which operates by means of a three-way solenoid valve, directing the flow of oil under pressure, to a slide piston mechanism. At full load, oil under pressure pushes against the piston, opposing the spring and closing the capacity control device. At reduced load conditions, the oil is diverted to the suction side of the compressor, and the spring forces the piston to open the capacity control device, which reduces the displacement and consequently reduces the capacity of the compressor. CXH models aare also available with optional stepless capacity control system offering 25% to 100% control.
Electronic Protection Device
All Frascold screw compressors are equipped with electronic protection KRIWAN INT 68 FRY, complete with thermistor sensors, performing the following functions:
• Control of maximum temperature of the electric motor +120°C, through six PTC thermistors, fitted to the stator winding. • Control of the maximum discharge temperature +120°C through PTC sensor placed on compressor discharge side.• Control of rotation direction of the electric motor and phase sequence.• Protection of phase and voltage failures.• Control of breakage and short circuit in chain of PTC sensors.
26Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Com
pres
sors
COMPRESSORSFRASCOLD TWIN SCREW
R-TSH SERIES: This range comprises of eight models from nominal 40HP to 120HP, with displacements from 120 to 360 cubic meters per hour at 50Hz. The R-TSH range is suited to air conditioning and medium/ high temperature applications, in the temperature operating range from + 7.5°C to – 20°C SST on R404A/R507A; +12.5°C to -20°C on R22; +20°C to -10°C on R134a.
R-TSL SERIES: This range comprises of eight models from nominal 30HP to 100HP, with displacements from 120 to 360 cubic meters per hour at 50Hz. The R-TSL range is suited to low temperature applications, in the temperature operating range from -20°C to -45°C on R404A/ R507A.
• Ratings at 50deg Condensing at European standard EN12900 / 10deg Suction gas superheating / with economiser• Oil cooler required for most applications below -20deg SST. Please contact Realcold for details and selection.• Please refer to Frascold selection software or contact Realcold for ratings at other conditions.
RTSH - Med / High Temperature
RealcoldStock No.
Model Nom Hp Amps Mra
DispM3/HR
CapSteps %
Watts @ -5 SST (ECO) Price$ Excl. GSTR404A R134a
C5261 R-TSH8 40 120Y 40 85 120 100-50 81000 52400
C5262 R-TSH8 50 150Y 50 108 150 100-50 103600 64800
C5263 R-TSH8 60 186Y 60 126 186 100-50 127400 79100
C5264 R-TSH8 70 210Y 70 148 210 100-50 144900 90800
C5265 NRH3 80 240Y 80 170 240 100-75-50 165700 103900
C5266 NRH3 90 270Y 90 185 270 100-75-50 187900 117500
C5267 NRH4 100 300Y 100 216 300 100-75-50 207800 129600
C5268 NRH5 120 360Y 120 230 360 100-75-50 251500 157000
RTSL - Low Temperature
RealcoldStock No.
Model Nom Hp Amps Mra
DispM3/HR
CapSteps %
Watts @ -25 SST (ECO) Price$ Excl. GSTR404A
C5271 R-TSL1 30 120Y 30 51 120 100-50 39200
C5272 R-TSL1 40 150Y 40 68 150 100-50 52200
C5273 R-TSL1 50 186Y 50 89 186 100-50 65400
C5274 R-TSL1 60 210Y 60 108 210 100-50 71500
C5275 NRL3 70 240Y 70 126 240 100-75-50 85600
C5276 NRL3 80 270Y 80 148 270 100-75-50 96300
C5277 NRL4 90 300Y 90 170 300 100-75-50 106600
C5278 NRL5 100 360Y 100 185 360 100-75-50 129500
27Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Com
pres
sors
COMPRESSORSFRASCOLD TWIN SCREW
CXHO SERIES: This range of compact twin screw compressors comprises of twenty seven models ranging from a nominal 50HP to 300HP, with displacements from 199 to 912 cubic me-ters per hour at 50Hz. The CXH range is designed for close coupled systems and incorporates a high efficiency oil separator and oil control system. Suited to applications in the operating temperature range from +12.5°C to -15°C SST on R22/ R407C/ R134a/ R404A.
• Lubricant oil charge and oil filter• Discharge service valve complete with check valve• Suction service valve with flange and solder sleeve• Electric oil heater with temperature control• Oil equalisation valve for parallel compressors application
• KRIWAN Electronic protection module• Maximum discharge temperature PTC sensor• PTC sensors for motor protection• Step capacity and stepless control device• Connection for liquid injection or economiser fittings
• Ratings at 50deg Condensing temp at European standard EN12900 / 10deg Suction gas superheating / with economiser
• CXH Compressors are also suitable for operation with R404A/R507C & R134a for medium temperature applications.
Standard Equipment
CXHO - Medium Temperature
RealcoldStock No.
Model Nom Hp Amps Mra
DispM3/HR
CapSteps %
Watts @ -5 SST (ECO) Price$ Excl. GSTR407C R134a
CFS0020 CXH01-50-199Y 50 80 199 25-50-75-100 — 132500
CFS0022 CXH01-60-230Y 60 98 230 25-50-75-100 — 155000
CFS0024 CXH01-70-264Y 70 125 264 25-50-75-100 — 171300
CFS0026 CXH01-80-298Y 80 145 298 25-50-75-100 — 197600
CFS0028 CXH01-90-340Y 90 160 340 25-50-75-100 — 187230
CFS0030 CXH01-100-370Y 100 175 370 25-50-75-100 — 235100
CFS0034 CXH51-110-398Y 110 180 398 25-50-75-100 — 275800
CFS0036 CXH51-125-468Y 125 198 468 25-50-75-100 — 318300
CFS0038 CXH51-140-538Y 140 221 538 25-50-75-100 — 357200
CFS0042 CXH91-160-620Y 160 283 620 25-50-75-100 — 300770
CFS0044 CXH91-180-702Y 180 315 702 25-50-75-100 — 427200
CFS0046 CXH91-210-810Y 210 356 810 25-50-75-100 — 550000
CFS0048 CXH91-240-912Y 240 427 912 25-50-75-100 — 591100
CXHO - Low / Med Temperature
RealcoldStock No.
Model Nom Hp Amps Mra
DispM3/HR
CapSteps %
Watts @ -5 SST (ECO) Price$ Excl. GSTR407C R134a
CFS0060 CXH02-70-199Y 70 128 199 25-50-75-100 188900 —
CFS0062 CXH02-80-230Y 80 145 230 25-50-75-100 217200 —
CFS0064 CXH02-90-264Y 90 160 264 25-50-75-100 243800 —
CFS0066 CXH02-100-298Y 100 175 298 25-50-75-100 275200 —
CFS0072 CXH52-110-316Y 110 184 316 25-50-75-100 314700 —
CFS0068 CXH52-120-340Y 120 195 340 25-50-75-100 341200 —
CFS0074 CXH52-125-372Y 125 218 372 25-50-75-100 364100 —
CFS0076 CXH52-140-428Y 140 245 428 25-50-75-100 391800 —
CFS0078 CXH52-160-468Y 160 282 468 25-50-75-100 446600 —
CFS0082 CXH92-180-545Y 180 332 545 25-50-75-100 546600 —
CFS0084 CXH92-210-620Y 210 375 620 25-50-75-100 606800 —
CFS0086 CXH92-240-702Y 240 427 702 25-50-75-100 672800 —
CFS0088 CXH92-280-810Y 280 455 810 25-50-75-100 774400 —
CFS0090 CXH92-300-912Y 300 474 912 25-50-75-100 856400 —
28Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Com
pres
sors
Semi-Hermetic Screw Compressor - AccessoriesModel No. Remote Oil
SeparatorVisual Indicator For Oil Strainer Clogging
Electric Indicator For Oil Strainer Clogging
Water Cooled Oil Cooler
Economizer Kit for R22
Economizer Kit for R404A-R507A
Lubricant for R22 (19I can)
Lubricant for R404A, 50W7A, R143A
R-TSH8 40 120Y TOOWK200 TOOWK150 TOOWK151 SZ-WOC1 — — SZ-OIL2 (FCH) SZ-OIL3 (FCL)
R-TSH8 50 150Y TOOWK200 TOOWK150 TOOWK151 SZ-WOC1 — — SZ-OIL2 (FCH) SZ-OIL3 (FCL)
R-TSH8 60 186Y TOOWK200 TOOWK150 TOOWK151 SZ-WOC1 — — SZ-OIL2 (FCH) SZ-OIL3 (FCL)
R-TSH8 70 210Y TOOWK200 TOOWK150 TOOWK151 SZ-WOC1 — — SZ-OIL2 (FCH) SZ-OIL3 (FCL)
R-TSH8 80 240Y TOOWK201 TOOWK150 TOOWK151 SZ-WOC1 — — SZ-OIL2 (FCH) SZ-OIL3 (FCL)
R-TSH8 90 270Y TOOWK201 TOOWK150 TOOWK151 SZ-WOC1 — — SZ-OIL2 (FCH) SZ-OIL3 (FCL)
R-TSH8 100 300Y TOOWK201 TOOWK150 TOOWK151 SZ-WOC1 — — SZ-OIL2 (FCH) SZ-OIL3 (FCL)
R-TSH8 120 360Y TOOWK201 TOOWK150 TOOWK151 SZ-WOC2 — — SZ-OIL2 (FCH) SZ-OIL3 (FCL)
R-TSL1 30 120Y TOOWK200 TOOWK150 TOOWK151 SZ-WOC2 TOOWK300 TOOWK301 SZ-OIL2 (FCH) SZ-OIL3 (FCL)
R-TSL1 40 150Y TOOWK200 TOOWK150 TOOWK151 SZ-WOC1 TOOWK300 TOOWK301 SZ-OIL2 (FCH) SZ-OIL3 (FCL)
R-TSL1 50 186Y TOOWK200 TOOWK150 TOOWK151 SZ-WOC1 TOOWK302 TOOWK303 SZ-OIL2 (FCH) SZ-OIL3 (FCL)
R-TSL1 60 210Y TOOWK200 TOOWK150 TOOWK151 SZ-WOC1 TOOWK302 TOOWK303 SZ-OIL2 (FCH) SZ-OIL3 (FCL)
R-TSL1 70 240Y TOOWK200 TOOWK150 TOOWK151 SZ-WOC1 TOOWK304 TOOWK305 SZ-OIL2 (FCH) SZ-OIL3 (FCL)
R-TSL1 80 270Y TOOWK200 TOOWK150 TOOWK151 SZ-WOC1 TOOWK304 TOOWK305 SZ-OIL2 (FCH) SZ-OIL3 (FCL)
R-TSL1 90 300Y TOOWK201 TOOWK150 TOOWK151 SZ-WOC2 TOOWK306 TOOWK307 SZ-OIL2 (FCH) SZ-OIL3 (FCL)
R-TSL1 100 360Y TOOWK201 TOOWK150 TOOWK151 SZ-WOC2 TOOWK306 TOOWK307 SZ-OIL2 (FCH) SZ-OIL3 (FCL)
COMPRESSORSSEMI-HERMETIC SCREW ACCESSORIES
29Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
dens
ing
Uni
ts
Equipment Selection Notes
1) Select unit to best match required room capacity at most relevant evaporating and air-on ambient temperature. • 32 & 35deg ambient rated capacity selection will be sufficient for most applications with good unit ventilation.• Use 40deg rated capacity selection for constant extreme ambient locations or where ventilation is poor.• For 36deg ambient ratings add 32 & 40deg ratings and divide by two.
2) Select Evaporator to match unit capacity at 32deg. Matching at 40deg unit capacity will mean the evaporator will be under-sized for most of the year - This may result in low room RH and drying out of sensitive products.
• Select evaporator with 20 - 25% more capacity for high humidity applications.• Select evaporator with 30 - 35% less capacity for Low humidity applications.
3) Select Expansion valve and orifice to match unit capacity at desired evaporating temperature.• Use expansion valve with MOP function for low temp condensing unit applications (Not with CPR valve)• Use expansion valves that can operate at low superheat for high RH applications
CONDENSING UNITSCOOLROOM QUICK SELECTION GUIDE
Capacities Based On The Following:• Product entering 8deg above room temperature (Pre-frozen product only entering freezers)• Off-Cycle 'Air Defrost' for Coolrooms / 80mins per 24hrs total 'Electric Defrost' for Freezers.
PLEASE CONTACT REALCOLD FOR ASSISTANCE WITH SELECTION OR IF YOU REQUIRE A QUOTATION.
Coolroom Quick Selection GuideOutside Dimensions
COOLROOM+2ºC Room Temp / 35 ºC Ambient
FREEZER ROOM -18 ºC Room Temp / 35 ºC Ambient
L X W2.4m Height
Int Volume m3
Product Load Kg / 24hrs
Room Usage16/24 hr Watts
Int Volume m3
Product LoadKg / 24hrs
Room Usage
18/24 hr WattS
1.8 x 1.2 4.0 80Medium 1200
2.8 60Medium 1100
Heavy 1600 Heavy 1350
1.8 x 1.8 6.3 140Medium 1450
4.7 100Medium 1150
Heavy 2000 Heavy 1650
2.4 x 1.8 8.6 180Medium 1650
6.6 140Medium 1300
Heavy 2250 Heavy 1850
2.4 x 2.4 11.8 250Medium 2100
9.3 190Medium 1450
Heavy 2750 Heavy 2350
3.0 x 2.4 14.9 320Medium 2400
11.9 250Medium 1900
Heavy 3150 Heavy 2600
3.0 x 3.0 18.9 400Medium 2750
15.3 320Medium 2100
Heavy 3550 Heavy 2950
3.6 x 2.4 18.0 380Medium 2700
14.6 310Medium 2050
Heavy 3500 Heavy 2850
3.6 x 3.0 22.9 480Medium 3050
18.7 390Medium 2350
Heavy 4000 Heavy 3300
3.6 x 3.6 27.7 580Medium 3400
22.9 480Medium 2550
Heavy 4600 Heavy 3550
4.8 x 3.6 37.3 780Medium 4150
31.2 660Medium 3350
Heavy 5350 Heavy 4500
4.8 x 4.8 50.3 1050Medium 5150
44.5 890Medium 3550
Heavy 6500 Heavy 5050
Notes• Internal Volume Based on 75 mm insulation with
concrete floor• Allow an Additional 500W Per Glass Door Insert
• Internal Volume Based on 150 mm insulation including floor
• Allow an Additional 600W Per Glass Door Insert
30Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
dens
ing
Uni
ts
CONDENSING UNITSTECUMSEH HERMETIC RECIPROCATING
• UL approved receivers
• Fan Guard
• Pre-Wired compressor and fan motor
• Suction line isolating valve
• Liquid line isolating valves
• FH/TFH models are supplied complete with DP control / CC heater, oil level sight glass fitted CAJ4517, CAJ4519 complete with DP control
• 12 month manufacturers warranty
• Manufactured by Tecumseh Europe
Tecumseh Sealed Condensing Units
L’Unite Hermetique is a brand name of Tecumseh, recognised as a leader in commercial refrigeration compressor manufacture. For more than 50 years, Tecumseh has been developing and manufacturing compressors, condensing units and fan motors.
Reliability, performance, silent operation, easy installation and ergonomics are the driving force behind the company, with an overall focus on differentiation and development of customer loyalty.
L’Unite has a proud tradition and a strong future, and the condensing unit range to suit a wide variety of applications.
Tecumseh Sealed Condensing Units Feature:
31Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
dens
ing
Uni
ts
R404A Medium Temperature (220-240/1/50)RealcoldStock No.
Model Nominal HP Capacity (Watts) - Ambient Temp 32ºC Price$ Excl. Gst-10ºC -5ºC 0ºC 7.5ºC 10ºC
C9408-AE2^ AE4430ZHR-FZ1A 1/4 445 534 628 773 833
C9412-AE2^ AE4440ZHR-FZ1A 1/3 600 712 831 1012 1085
C9426-AE2^ AE450ZHR-FZ1A 3/7 738 881 1034 1274 1374
C9430-AE2^ AE4460ZHR-FZ1C 1/2 880 1035 1195 1435 1532
C9432^ CAE9470ZMHR 1/2 1123 1322 1532 1852 1984
C9444^ CAJ9510ZMHR 1 1599 1888 2196 2671 2876
C9448 CAJ4517ZHR 1.1/4 2354 2792 3225 3842 4079
C9450 CAJ4519ZHR 1.1/2 2924 3452 3999 4812 5136
C9470 FH4524ZHR 2 3180 3768 4400 5342 5722
CONDENSING UNITSTECUMSEH HERMETIC RECIPROCATING
SpecificationsUnit Model Compressor Fan
Motor Size
Air Volume m3/hr
Receiver Volume (L)
Connections (mm/in) Dimensions (mm) Weight (kg)
Sound Power dBA
Hp cc mra Liquid Suction Width Depth Height
AE4430ZHR-FZ1A 1/4 5.70 3.6 205 410 0.75 9.5 (3/8) 6.4 (1/4) 389 330 257 18.5 59
AE4440ZHR-FZ1A 1/3 7.55 3.8 250 800 0.75 9.5 (3/8) 6.4 (1/4) 490 350 292 26.0 65
AE450ZHR-FZ1A 3/7 9.4 4.8 250 980 0.75 9.5 (3/8) 6.4 (1/4) 490 350 292 27.0 69
AE4460ZHR-FZ1C 1/2 11.30 4.7 250 980 0.75 9.5 (3/8) 6.4 (1/4) 490 356 292 24.5 69
CAE9470ZMHR 1/2 13.3 6.4 300 1130 0.75 9.5 (3/8) 6.4 (1/4) 490 430 338 23.4 69
CAJ9510ZMHR 1 18.30 8.2 300 900 1.50 15.9 (5/8) 9.5 (3/8) 486 430 338 33.0 66
CAJ4517ZHR 1 1/4 25.95 13.2 350 1700 2.35 15.9 (5/8) 9.5 (3/8) 620 510 450 41.0 71
CAJ4519ZHR 1 1/2 34.45 15.7 350 1700 2.35 15.9 (5/8) 9.5 (3/8) 620 510 450 41.0 71
FH4524ZHR 2 43.5 18.9 356 2480 3.90 15.9 (5/8) 9.5 (3/8) 620 510 450 57.0 78
• ^ Note that these units do not include a pressure switch.• All ratings are based on an ambient of +30°C , 10K Superheat, 2K Sub-Cooling.• Refer to warranty section of catalogue for warranty details.
32Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
dens
ing
Uni
ts
CONDENSING UNITSTECUMSEH HERMETIC RECIPROCATING
R134a Medium Temperature (220-240/1/50)RealcoldStock No.
Model Nominal HP Capacity (Watts) - Ambient Temp 32ºC Price$ Excl. Gst-10ºC -5ºC 0ºC 7.5ºC 10ºC
C9126-AE2^ AE4425YHR-FZ1A 1/5 334 418 507 644 700
C9130-AE2^ AE4430YHR-FZ1A 1/4 416 516 625 796 867
C9142-AE2^ AE4440YHR-FZ1A 1/3 546 667 797 997 1079
C9150-AE2^ AE4450YHR-FZ1C 3/8 657 810 971 1217 1318
C9152-AE2^ AE4456YHR-FZ1C 3/7 721 888 1069 1353 1470
C9160^ CAJ4492YHR 3/4 1254 1552 1878 2390 2600
C9162^ CAJ4511YHR 1 1576 1917 2279 2826 3043
C9170 FH4518YHR 1.1/2 2425 3026 3690 4760 5214
C9173 FH4525YHR 2 2925 3629 4389 5581 6076
For 40ºC Ambient capacity, please contact the Technical Department.
SpecificationsUnit Model Compressor Fan
Motor Size
Air Volume m3/hr
Receiver Volume (L)
Connections (mm/in) Dimensions (mm) Weight (kg)
Sound Power dBA
Hp cc mra Liquid Suction Width Depth Height
AE4425YHR-FZ1A 1/5 7.55 2.6 205 340 0.75 9.5 (3/8) 6.4 (1/4) 417 314 224 17.4 58
AE4430YHR-FZ1A 1/4 8.85 3.6 205 410 0.75 9.5 (3/8) 6.4 (1/4) 389 330 257 17.4 59
AE4440YHR-FZ1A 1/3 12.05 4.2 205 410 0.75 9.5 (3/8) 6.4 (1/4) 389 330 257 19.0 59
AE4450YHR-FZ1C 3/8 14.15 5.0 250 800 0.75 9.5 (3/8) 6.4 (1/4) 490 350 292 26.0 68
AE4456YHR-FZ1C 3/7 16.00 6.0 250 980 0.75 12.7 (1/2) 6.4 (1/4) 490 350 292 28.0 69
CAJ4492YHR 3/4 25.95 8.6 300 900 2.35 15.9 (5/8) 9.5 (3/8) 486 430 338 31.0 63
CAJ4511YHR 1 32.70 9.1 300 900 2.35 15.9 (5/8) 9.5 (3/8) 486 430 338 32.0 64
FH4518YHR 1.1/2 53.20 12.0 356 2250 2.35 15.9 (5/8) 9.5 (3/8) 620 510 450 51.0 76
FH4525YHR 2 74.25 16.1 356 2250 3.90 15.9 (5/8) 9.5 (3/8) 630 510 450 56.0 77
• ^ Note that these units do not include a pressure switch.• All ratings are based on an ambient of +30°C , 10K Superheat, 2K Sub-Cooling.• Refer to warranty section of catalogue for warranty details.
33Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
dens
ing
Uni
ts
R404A Low Temperature (220-240/1/50)RealcoldStock No.
Model Nominal HP Capacity (Watts) - Ambient Temp 32ºC Price$ Excl. Gst-30ºC -25ºC -20ºC -15ºC -10ºC
220/240 Volt 50 Hz Single Phase
C9422^ CAE2424ZBR 5/8 518 645 772 910 1057
C9436^ CAJ2432ZBR 3/4 594 729 864 1022 1195
C9438^ CAJ2446ZBR 1 937 970 1416 1690 1989
C9440^ CAJ2464ZBR 1.1/2 1172 1463 1755 2067 2382
C9462 FH2480ZBR 2 1641 2030 2519 2980 3417
For 40ºC Ambient capacity, please contact the Technical Department.
SpecificationsUnit Model Compressor Fan
Motor Size
Air Volume m3/hr
Receiver Volume (L)
Connections (mm/in) Dimensions (mm) Weight (kg)
Sound Power dBA
Hp cc mra Liquid Suction Width Depth Height
CAE2424ZBR 5/8 15.00 5.3 250 800 0.75 9.5 (3/8) 6.4 (1/4) 510 356 292 26.1 64
CAJ2432ZBR 3/4 18.30 5.6 250 550 1.50 12.7 (1/2) 6.4 (1/4) 485 342 299 31.0 59
CAJ2446ZBR 1 26.18 8.1 300 900 2.35 12.7 (1/2) 9.5 (3/8) 486 430 338 34.0 65
CAJ2464ZBR 1.1/2 35.45 10.2 300 900 2.35 15.9 (5/8) 9.5 (3/8) 486 430 338 35.0 63
FH2480ZBR 2 53.20 19.9 300 2200 3.00 15.9 (5/8) 9.5 (3/8) 620 510 450 57.0 70
• ^ Note that these units do not include a pressure switch.• All ratings are based on an ambient of +30°C , 10K Superheat, 2K Sub-Cooling.• Refer to warranty section of catalogue for warranty details.
CONDENSING UNITSTECUMSEH HERMETIC RECIPROCATING
34Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
dens
ing
Uni
ts
FH Series CAJ Series
CAE Series AEZ Series
CONDENSING UNITSTECUMSEH HERMETIC RECIPROCATING
Drawings
35Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
dens
ing
Uni
ts
Easypack - Realcold Condensing Units Feature:
• All units fitted with dual pressure controls
• Compressor / fan motor wired (Single Phase Units Only)
• Liquid line isolating valves
• Suction isolating valves
• FH & TFH models are complete with crankcase heaters, oil sight glasses
CONDENSING UNITSEASYPACK HERMETIC
R404A Medium Temperature (240/1/50)RealcoldStock No.
Model Nominal HP Capacity (Watts) - Ambient Temp 32ºC Price$ Excl. Gst-25ºC -20ºC -15ºC -10ºC -5ºC 0ºC 5ºC 10ºC 15ºC
C0757E RMTZ112 1.1/8 984 1305 1651 2108 2405 2807 3220 3635 4047
C0758E RMTZ125 1.1/4 — 1472 1857 2272 2845 3168 3634 4100 4555
C0759E RMTZ150 1.1/2 — 1570 2027 2526 3638 4241 4864 5499 6132
C0762E RMTZ200 2 — — 2903 3586 4291 5023 5786 6587 7430
C0764E RMTXZ250 2.1/2 — — 3936 4855 5850 6764 7754 8767 9801
For 40ºC Ambient capacity, please contact the Technical Department.Note: These units are not pre-wired.
Features of the Tandem System
• Twin compressor configuration enable a more precise control of the system capacity to match the cooling demand and thereby the number of starts to a minimum to improve reliability.
• Capacity control - cycle one compressor off at low load conditions for power saving.• Sequence start up of compressors reducing start up current.• 50% redundant capacity in event of one compressor failing.
36Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
dens
ing
Uni
ts
R404A Medium Temperature (415/3/50)RealcoldStock No.
Model Nominal HP Capacity (Watts) - Ambient Temp 32ºC Price$ Excl. Gst
-15ºC -10ºC -5ºC 0ºC 5ºC 10ºC 15ºC
C0964E RMTXZ300 3 4654 5628 6740 7908 9149 10481 11922
C0968E RMTXZ450 4.1/2 5871 7332 8948 10685 12509 14387 16282
C0971E RMTXZ500 5 6059 7567 9713 11323 13365 15382 17269
C0973E RMTXZ600 6.1/4 8136 10023 12034 14168 16426 18808 21313
C0977E* RMTXZ900T 9 11375 13946 17104 20605 24207 27667 30744
C0980E* RMTXZ1000T 10 13721 16904 20225 23683 27278 31010 34880
C0987E RMTXZ1500T 15 25239 31239 37659 44499 51756 59436 67533
C0985E* RMTXZ1200T 12 19226 22356 25974 30077 34665 39738 45297
* Fitted with multiple compressors
R404A Low Temperature (240/1/50)RealcoldStock No.
Model Nominal HP Capacity (Watts) - Ambient Temp 32ºC Price$ Excl. Gst
-40ºC -35ºC -30ºC -25ºC -20ºC -15ºC -10ºC -5ºC 0ºC
C0787E RLTZ150 1 1/2 668 907 1184 1495 1840 2212 2608 — —
C0789E RLTZ200 2 872 1334 1800 2271 2746 3225 3709 — —
R404A Low Temperature (415/3/50)RealcoldStock No.
Model Nominal HP Capacity (Watts) - Ambient Temp 32ºC Price$ Excl. Gst
-40ºC -35ºC -30ºC -25ºC -20ºC -15ºC -10ºC -5ºC 0ºC
C0793E RLTZ300 3 1194 1744 2356 3030 3767 4566 5427 — —
C0794E RLTZ400 4 1671 2429 3268 4188 5188 6269 7430 — —
C0795E RLTZ500 5 2024 3077 4202 5401 6674 8019 9438 — —
C0796E RLTZ600T 6 2338 3408 4633 5921 7296 8619 10006 — —
C0797E* RLTZ800T 8 3335 4814 6508 8417 10540 12878 15430 — —
C0798E* RLTZ1000T 10 4138 5809 7713 9850 12220 14822 17658 — —
* Fitted with multiple compressors. For 40ºC Ambient capacity, please contact the Technical Department.Note: C0796E no cover available
Easypack Weather ShieldsRealcoldStock No.
Easypack Model Price$ Excl. GST
C1940 RMTZ112 and RLTZ150
C1941 RMTZ125 to RMTXZ300, RLTZ200 to RLTXZ300
C1942 RMTXZ450 to RMTXZ600, RLTXZ400 to RLTXZ500
C1943 RMTXZ900T to RMTXZ1200T, RLTXZ800T to RLTXZ1000T
C1944 RMTXZ1500T
CONDENSING UNITSEASYPACK HERMETIC
37Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
dens
ing
Uni
tsCONDENSING UNITS
EASYPACK TECHNICAL DATA
Easy
pack
Tec
hnic
al D
ata
Real
cold
Stoc
k N
o.M
odel
Com
pres
sor
Fan
Mot
orRe
c Vo
l. (L
)Co
nnec
tion
Mod
elPh
ase
HP
Dis
p./
Com
p (c
m3 )
Mra
/ Co
mp
No.
x S
ize
Airfl
ow
L/se
cM
ra/
Mot
orSu
ctio
n m
m
(inch
)Liq
uid
m
m (i
nch)
C075
7ERM
TZ11
2CA
J951
3Z1
1.1/8
24.2
010
.91x
350
2250
0.65
2.35
15.9
(5/8
)9.
5 (3
/8)
C075
8ERM
TZ12
5CA
J451
7Z1
1.1/4
25.9
511
.51x
400
3450
0.82
2.35
15.9
(5/8
)9.
5 (3
/8)
C075
9ERM
TZ15
0CA
J451
9Z1
1.1/5
34.4
516
.01x
400
3450
0.82
2.35
15.9
(5/8
)9.
5 (3
/8)
C076
2ERM
TZ20
0FH
4524
Z1
243
.50
19.0
1x40
034
500.
822.
3515
.9 (5
/8)
9.5
(3/8
)
C076
4ERM
TXZ2
50FH
4531
Z1
2.1/
256
.65
27.0
1x40
030
700.
823.
9022
.2 (7
/8)
9.5
(3/8
)
C096
4ERM
TXZ3
00TF
H45
40Z
33
74.2
59.
71x
400
3000
0.82
6.00
22.2
(7/8
)12
.7 (1
/2)
C096
8ERM
TXZ4
50TA
G45
53Z
34.
1/2
100.
7014
.42x
400
6000
0.82
6.00
22.2
(7/8
)12
.7 (1
/2)
C097
1ERM
TXZ5
00TA
G45
61Z
35
112.
5015
.02x
400
6000
0.82
6.00
28.6
(1.1/
8)12
.7 (1
/2)
C097
3ERM
TXZ6
00TA
G45
73Z
36.
1/4
134.
8019
.02x
400
6000
0.82
9.00
28.6
(1.1/
8)12
.7 (1
/2)
C097
7ERM
TXZ9
00T
2 x
TAG
4553
Z3
910
0.70
25.5
2x50
010
500
1.95
12.0
028
.6 (1
.1/8)
15.9
(5/8
)
C098
0ERM
TXZ1
000T
2 x
TAG
4561
Z3
1011
2.50
25.5
2x50
094
501.9
512
.00
28.6
(1.1/
8)15
.9 (5
/8)
C098
5ERM
TXZ1
200T
2 x
TAG
4573
Z3
1213
4.80
39.0
2x50
094
501.9
512
.00
28.6
(1.1/
8)15
.9 (5
/8)
C098
7ERM
TXZ1
500T
3 x
TAG
P456
1Z3
1511
2.50
42.0
3x50
017
750
1.95
17.4
028
.6 (1
.1/8)
15.9
(5/8
)
C078
7ERL
TZ15
0CA
J246
4Z1
1.1/2
34.4
510
.51x
350
2250
0.65
2.35
15.9
(5/8
)9.
5 (3
/8)
C078
9ERL
TZ20
0FH
2480
Z1
253
.20
17.0
1x40
034
500.
822.
3515
.9 (5
/8)
9.5
(3/8
)
C079
3ERL
TZ30
0TF
H25
11Z
33
74.2
56.
01x
400
3000
0.82
3.9
15.9
(5/8
)9.
5 (3
/8)
C079
4ERL
TZ40
0TA
G25
16Z
34
112.
5010
.62x
400
6000
0.82
622
.2 (7
/8)
9.5
(3/8
)
C079
5ERL
TZ50
0TA
G25
22Z
35
134.
8013
.52x
400
6600
0.82
622
.2 (7
/8)
9.5
(3/8
)
C079
6ERL
TZ60
0T2
x TF
H25
11Z
36
74.2
59.
42x
400
6000
0.82
628
.6 (1
.1/8)
9.5
(3/8
)
C079
7ERL
TZ80
0T2
x TA
G25
16Z
38
112.
5020
.82x
500
1150
01.9
512
28.6
(1.1/
8)15
.9 (5
/8)
C079
8ERL
TZ10
00T
2 x
TAG
2522
Z3
1013
4.80
29.5
2x50
011
050
1.95
1228
.6 (1
.1/8)
15.9
(5/8
)
38Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
dens
ing
Uni
ts
Easy
pack
Tec
hnic
al D
ata
(con
tinue
d)Re
alco
ldSt
ock
No.
Mod
elW
eigh
t (k
g)D
imen
sion
s (m
m)
Soun
d Po
wer
Le
vel d
BA
Wea
ther
Sh
ield
Acc
esso
ries
Leng
thW
idth
Hei
ght
Oil
Sep
L/Lin
e D
rier
L/Si
ght
Gla
ssL/
Sol.
Valv
eSu
ctio
n A
cc.
Pres
sure
R.
Valv
eD
p Sw
itch
C075
7ERM
TZ11
247
550
650
465
76C1
940
—YE
SYE
SYE
S—
YES
YES
C075
8ERM
TZ12
560
600
600
560
77C1
941
—YE
SYE
SYE
S—
YES
YES
C075
9ERM
TZ15
060
600
600
560
79C1
941
—YE
SYE
SYE
S—
YES
YES
C076
2ERM
TZ20
073
600
600
560
79C1
941
—YE
SYE
SYE
S—
YES
YES
C076
4ERM
TXZ2
5076
600
600
560
79C1
941
—YE
SYE
SYE
S—
YES
YES
C096
4ERM
TXZ3
0080
600
600
560
82C1
941
—YE
SYE
SYE
S—
YES
YES
C096
8ERM
TXZ4
5011
810
8068
056
584
C194
2—
YES
YES
YES
YES
YES
YES
C097
1ERM
TXZ5
0011
810
8068
056
584
C194
2—
YES
YES
YES
YES
YES
YES
C097
3ERM
TXZ6
0013
510
8068
056
584
C194
2—
YES
YES
YES
YES
YES
YES
C097
7ERM
TXZ9
00T
213
1420
730
870
87C1
943
—YE
SYE
SYE
SYE
SYE
SYE
S
C098
0ERM
TXZ1
000T
218
1420
730
870
87C1
943
—YE
SYE
SYE
SYE
SYE
SYE
S
C098
5ERM
TXZ1
200T
218
1420
730
870
87C1
943
—YE
SYE
SYE
SYE
SYE
SYE
S
C098
7ERM
TXZ1
500T
327
1900
1120
870
90C1
944
—YE
SYE
SYE
SYE
SYE
SYE
S
C078
7ERL
TZ15
040
550
650
395
76C1
940
YES
YES
YES
YES
YES
YES
YES
C078
9ERL
TZ20
073
600
600
560
79C1
941
YES
YES
YES
YES
YES
YES
YES
C079
3ERL
TZ30
080
600
600
560
82C1
941
YES
YES
YES
YES
YES
YES
YES
C079
4ERL
TZ40
010
710
8068
056
581
C194
2YE
SYE
SYE
SYE
SYE
SYE
SYE
S
C079
5ERL
TZ50
010
710
8068
056
581
C194
2YE
SYE
SYE
SYE
SYE
SYE
SYE
S
C079
6ERL
TZ60
0T15
610
8080
057
081
C194
2YE
SYE
SYE
SYE
SYE
SYE
SYE
S
C079
7ERL
TZ80
0T21
014
2073
087
082
C194
3YE
SYE
SYE
SYE
SYE
SYE
SYE
S
C079
8ERL
TZ10
00T
215
1420
730
870
83C1
943
YES
YES
YES
YES
YES
YES
YES
CONDENSING UNITSEASYPACK TECHNICAL DATA
39Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
dens
ing
Uni
ts
Realcold Milk Vat Units (RMV)
Next Generation for On-farm Refrigeration. Purpose built with the milk shed environment and servicing in mind.
Ease of service: Simple in its design. No unnecessary complicated electronics.
Proven reliability: Retains use of reciprocating technology in an innovative way.
Availability: Units held in stock.
Affordable: Competitively priced.
Superior Efficiency: Multiplexed compressors enable the most efficient use of energy.
Ease of adaptability: Adaptable to a wide range of applications, from a single platform:
• Saturation temperatures from +20°C to -35°C• Condensing temperatures up to +55°C• Capacities from 2 kW to 40 kW
On Farm Refrigeration (380-415/3/50)RealcoldStock No.
Model Compressor Nom. HP Cooling Capacity kW
Dimensions (mm) Weight (Dry) Kg
Price$ Excl. GstL D H
C6720 RMV 450 TAG 4553Z 4.5 11.4 1080 680 565 118
C6721 RMV 600 TAG 4573Z 6.0 15.1 1080 680 565 135
C6722* RMV 900 TAG 4553Z 9.0 22.0 1420 730 870 213
C6723* RMV 1000 TAG 4561Z 10.0 25.1 1420 730 870 218
C6724* RMV 1200 TAG 4573Z 12.0 31.9 1420 730 870 218
C6725* RMV 1500 TAG 4561Z 15.0 36.3 1900 1120 870 300
* Fitted with multiple compressors.
CONDENSING UNITSREALCOLD MILK VAT AIR COOLED
Realcold Condensing Unit Support LegRealcoldStock No.
Description Price$ Excl. GST
D0177
• 3.0 mm folded aluminium
• 350 mm nominal height (without adjustment)
• Stainless steel plate with M16 SS bolt for levelling & height adjustment
40Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
dens
ing
Uni
ts
Realpack Features:
• Tecumseh L’Unite Hermetique compressors designed for R404A, R134a and R507 refrigerants• Suitable for ambient temperatures up to 46°C• Condenser fan control for stable operation, Condenser coil protection• Oil Separator on all models, Liquid drier and sight glass on all models• Suction Accumulator on low temperature models• Easy access to all serviceable components• Easy and cost effective installation - fully wired & robust powder coated enclosure
R404A Medium Temperature (240/1/50)RealcoldStock No.
Model Nominal HP Capacity (Watts) - Ambient Temp 32ºC Price$ Excl. Gst-15ºC -10ºC -5ºC 0ºC 5ºC 10ºC 15ºC
C9513 RPM125 1 1/4 1660 2130 2813 3241 3650 4146 4484
C9515 RPM150 1 1/2 2297 2900 3654 4512 5210 5799 6324
C9520 RPM200 2 2701 3461 4210 4887 5651 6407 7390
CONDENSING UNITSREALPACK
R404A Medium Temperature (415/3/50)RealcoldStock No.
Model Nominal HP Capacity (Watts) - Ambient Temp 32ºC Price$ Excl. Gst-15ºC -10ºC -5ºC 0ºC 5ºC 10ºC 15ºC
C9525 RPM250 2 1/2 3200 4315 5674 6537 7347 8777 9371
C9530 RPM300 3 4600 5626 6740 8930 10285 11459 12541
C9545 RPM450 4 1/2 5871 7242 8781 10632 12270 14221 15600
C9550 RPM500 5 6200 7680 9870 12650 14928 16900 19235
C9561 RPM600 6 1/4 7890 10050 13073 15088 17084 19531 21179
C9575 RPM750 7 1/2 9700 12722 15523 18308 21143 24084 27135
C9590* RPM1000 10 13002 16230 19830 25965 27220 30980 34380
C9596* RPM1250 12 1/2 19070 21060 26295 31107 35405 40609 44434
* Fitted with multiple compressors.
For 40ºC Ambient capacity, please contact the Technical Department.
41Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
dens
ing
Uni
tsCONDENSING UNITS
REALPACK
R404A Low Temperature (240/1/50)RealcoldStock No.
Model Nominal HP Capacity (Watts) - Ambient Temp 32ºC Price$ Excl. Gst-40ºC -35ºC -30ºC -25ºC -20ºC -15ºC -10ºC
C9522 RPL200 2 867 1298 1800 2250 2700 3376 4011
R404A Low Temperature (415/3/50)RealcoldStock No.
Model Nominal HP Capacity (Watts) - Ambient Temp 32ºC Price$ Excl. Gst-40ºC -35ºC -30ºC -25ºC -20ºC -15ºC -10ºC
C9532 RPL300 3 1696 1994 2454 3308 3815 4605 5538
C9542 RPL400 4 2098 2530 3200 4105 5180 6190 7400
C9552 RPL500 5 2110 3127 4230 5310 6542 7980 9440
C9580 RPL800 8 3450 4950 6350 8320 10400 12200 15338
C9593 RPL1000 10 4230 6002 8200 10010 12880 15340 18020
For 40ºC Ambient capacity, please contact the Technical Department.
42Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
dens
ing
Uni
ts
CONDENSING UNITSREALPACK TECHNICAL DATA
Real
pack
Tec
hnic
al D
ata
Real
cold
Stoc
k N
o.M
odel
Com
pres
sor
Fan
Mot
orRe
c Vo
l. (L
)Co
nnec
tion
Wei
ght
(kg)
Dim
ensi
ons
(mm
)So
und
Pow
er
Leve
l dB
AM
odel
Phas
eH
PD
isp.
/ Co
mp
(cm
3 )
Mra
/ Co
mp
No.
x
Size
Airfl
ow
L/se
cM
ra/
Mot
orSu
ctio
n m
m (i
nch)
Liqui
d
mm
(inc
h)Le
ngth
Wid
thH
eigh
t
Med
ium
Tem
pera
ture
C951
3RP
M12
5CA
J451
7Z1
1.1/4
25.9
57.
11x
300
399
0.37
2.3
15.9
(5/8
)9.
5 (3
/8)
7110
7048
075
065
C951
5RP
M15
0CA
J451
9Z1
1.1/2
34.4
59.
91x
350
778
0.70
2.3
15.9
(5/8
)9.
5 (3
/8)
7110
7048
075
068
C952
0RP
M20
0FH
4524
Z1
243
.50
10.3
1x35
077
80.
703.
915
.9 (5
/8)
9.5
(3/8
)81
1070
480
750
70
C952
5RP
M25
0TF
H45
31Z
32.
1/2
56.6
56.
52x
300
856
0.37
6.0
15.9
(5/8
)9.
5 (3
/8)
105
1285
625
820
69
C953
0RP
M30
0TF
H45
40Z
33
74.2
58.
92x
350
1459
0.70
6.0
15.9
(5/8
)9.
5 (3
/8)
118
1285
625
820
75
C954
5RP
M45
0TA
G45
53Z
34.
1/2
100.
709.
82x
350
1459
0.70
9.5
22.2
(7/8
)12
.7 (1
/2)
146
1285
625
820
78
C955
0RP
M50
0TA
G45
61Z
35
112.
5011
.42x
350
1402
0.70
9.5
22.2
(7/8
)12
.7 (1
/2)
148
1285
625
820
78
C956
1RP
M60
0TA
G45
73Z
36.
1/4
134.
8014
.32x
350
1402
0.70
9.5
22.2
(7/8
)12
.7 (1
/2)
150
1285
625
820
77
C957
5RP
M75
02
x TA
GP4
546Z
37.
1/2
90.2
08.
52x
500
3450
3.00
12.0
28.5
(1.1/
8)15
.9 (5
/8)
258
1660
790
1015
83
C959
0RP
M10
002
x TA
GP4
561Z
310
112.
5011
.42x
500
3450
3.00
12.0
28.5
(1.1/
8)15
.9 (5
/8)
258
1660
790
1015
83
C959
6RP
M12
502
x TA
GP4
573Z
312
.1/2
134.
8014
.32x
500
3450
3.00
12.0
28.5
(1.1/
8)15
.9 (5
/8)
258
1660
790
1015
83
Low
Tem
pera
ture
C952
2RP
L200
FH24
80Z
12
53.2
011
.51x
350
778
0.70
3.9
15.9
(5/8
)9.
5 (3
/8)
9010
7048
075
069
C953
2RP
L300
TFH
2511
Z3
374
.25
5.1
2x30
085
60.
376.
015
.9 (5
/8)
9.5
(3/8
)13
012
8562
582
072
C954
2RP
L400
TAG
2516
Z3
411
2.50
7.3
2x35
014
590.
706.
022
.2 (7
/8)
12.7
(1/2
)15
512
8562
582
071
C955
2RP
L500
TAG
2522
Z3
513
4.80
9.4
2x35
014
020.
709.
522
.2 (7
/8)
12.7
(1/2
)17
512
8562
582
076
C958
0RP
L800
2 x
TAG
P251
6Z3
811
2.50
7.3
2x50
034
503.
0012
.028
.5(1.
1/8)
15.9
(5/8
)25
816
6079
010
1579
C959
3RP
L100
02
x TA
GP2
522Z
310
134.
809.
42x
500
3450
3.00
12.0
28.5
(1.1/
8)15
.9 (5
/8)
258
1660
790
1015
79
43Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
dens
ing
Uni
tsCONDENSING UNITS
REALPACK WIRING DIAGRAM
1 Phase 1 Compressor
3 Phase 1 Compressor
3 Phase 2 Compressors
44Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
dens
ing
Uni
ts
CONDENSING UNITSREALPACK DRAWING
Single Fan Models
Twin Fan Models 300 & 350mm
Twin Fan Models 500mm
45Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
dens
ing
Uni
tsCONDENSING UNITS
FRASCOLD SEMI-HERMETIC
Semi-Hermetic Condensing Units
General Information
Functioning of condensing unit in countries where the ambient temperature is very high can be satisfying only if the air-condenser is correctly designed.
Frascold has developed these condensing units to answer the requirement of quick and easy installations in limited spaces and with very low noise levels.
These units mount semi-hermetic reciprocating compressors with a nominal electric power from 0,75 to 15 HP and a cooling capacity, reliability and fl exibility signifi cantly higher than the market standards.
The range includes 27 models for medium and low temperature application with a wide range of refrigerants:
R134a, R404A, R507A, R407C and R22.
The condensing units are available in the standard version or with a selection of refrigeration components already installed and factory tested. Some units are available with an integrated inverter compressor. The condensing units can be equipped with a weather protection housing painted with epoxy powder coating RAL 5009. All units are factory tested and pressurised with a protective nitrogen charge.
Main features of Frascold units
• Studied to work with high ambient temperature
• PED certifi cation (97/23/EC)
• Low noise 6 Pole Fans
• Easy to install and service
• Compact design permitting an installation in limited spaces
• Certified quality components
• High performance even in critical operating conditions
• Condenser coils with large exchange surfaces
• Axial fans with high effi ciency blades and very low- noise in an extended speed-range, air-fl ow uniform and without vibrations
• Liquid receivers with PED certifi ed safety valve
• Wide range of application
• Semi-hermetic Frascold compressors
• Reduced energy consumption for the integrated inverter models
• Housing optimised for outside installation
Please contact your nearest Realcold branch or one of our applications engineers for other configurations that you may require. With the utilisation of world class manufacturing technology, Realcold can offer flexible design and fast turn around times.
MODEL DESIGNATION
Q521CO
MPRESSO
RM
OD
EL1760
CON
DEN
SERM
OD
EL
40
FAN
DIA
METER (CM
)
2
NU
MBER O
F FAN
S
.6
6 POLE FA
N M
OTO
RS
S-Series Condensing Unit
Q-Series Condensing Unit(Fitted with VSD Inverter)
46Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
dens
ing
Uni
ts
CONDENSING UNITSFRASCOLD SEMI-HERMETIC
R404A - Med Temperature (240/1/50)RealcoldStock No.
Model Nom. HP Amb Temp
Capacity in Watts Price$ Excl. Gst
-15ºC -10ºC -5ºC 0ºC 5ºC
CUF0013-1PH A16-550-352 135 2320 2850 3390 4040 4770
40 2100 2580 3130 3700 —
CUF0028-1PH A157-650-352 1.535 2940 3610 4340 5180 6150
40 2680 3300 3980 4760 —
CUF0049-1PH B210-1000-402 235 4020 4960 5980 7220 8550
40 3660 4530 5480 6560 —
R134a - Med Temperature (240/1/50)RealcoldStock No.
Model Nom. HP Amb Temp
Capacity in Watts Price$ Excl. Gst
-15ºC -10ºC -5ºC 0ºC 5ºC
CUF0014-1PH A16-550-352.6 135 1330 1690 2100 2580 3120
40 1230 1570 1960 2420 2910
CUF0024-1PH A157-550-352.6 1.535 1700 2150 2670 3250 3910
40 1560 2000 2490 3040 3670
CUF0044-1PH B210-550-352 235 2350 2990 3730 4560 5480
40 2170 2770 3470 4250 5120
R404A - Low Temperature (240/1/50)RealcoldStock No.
Model Nom. HP Amb Temp
Capacity in Watts Price$ Excl. Gst
-35ºC -30ºC -25ºC -20ºC -15ºC
CUF0014-1PH A16-550-352.6 135 820 1100 1420 1800 2210
40 700 970 1280 1610 2010
CUF0024-1PH A157-550-352.6 1.535 1000 1340 1760 2190 2710
40 860 1190 1560 1970 2450
CUF0044-1PH B210-550-352 235 1390 1850 2370 2990 3660
40 1240 1660 2130 2680 3320
Features include:• Frascold 1-phase Semi-Hermetic compressor• High Ambient air-cooled condensers• High efficiency external rotor fan motors• Liquid receiver with Rotalock valves• Crankcase heater fitted• Electronic motor protection• Auto reset dual pressure control
Specifications:• Ratings based on 20k suction superheat, 3k subcooling• For 43deg ambient ratings multiply 40deg by 0.95• Please refer to pages 63-65 for fitted optional accessories.
47Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
dens
ing
Uni
tsCONDENSING UNITS
FRASCOLD SEMI-HERMETIC
R404A - Med Temperature (415/3/50)RealcoldStock No.
Model Nom Hp
Amb Temp
Capacity In Watts Price $Excl. Gst
-15ºC -10ºC -5ºC 0ºC 5ºC
CUF0013 A16-550-352 135 2320 2850 3390 4040 4770
40 2100 2580 3130 3700 —
CUF0028 A157-650-352 1.535 2940 3610 4340 5180 6150
40 2680 3300 3980 4760 —
CUF0049 B210-1000-402 235 4020 4960 5980 7220 8550
40 3660 4530 5480 6560 —
CUF0058 D211-1000-402 235 4690 5750 6960 8320 9740
40 4190 5210 6310 7560 —
CUF0074 D313-1400-402 335 5640 6960 8500 10150 11990
40 5140 6370 7700 9300 —
CUF0086 D315-1400-402 335 6560 7990 9560 11320 13280
40 5960 7200 8700 10300 —
CUF0103 D418-1700-402 435 7790 9470 11290 13460 15730
40 7140 8680 10350 12340 —
CUF0112 Q521-1700-402 535 8640 10600 12790 15210 17710
40 7680 9560 11560 13780 —
CUF0124 Q525-2200-402 535 10270 12530 15110 18040 21340
40 9310 11370 13720 16390 —
CUF0133 Q728-2800-502 7.535 12610 14940 17970 21400 25220
40 11080 13640 16420 19570 —
CUF0145 Q733-2800-502 7.535 13810 16970 20400 24010 28220
40 12550 15290 18600 21880 —
CUF0157 S1242-3900-552 1235 17000 21080 25540 30610 36370
40 15350 19120 23250 27990 —
CUF0169 S1552-4900-552 1535 22070 26660 32190 38220 45120
40 20040 24720 29590 35170 —
CUF0181 S2056-4900-552 2035 24980 30140 36020 42730 50390
40 22900 27340 33070 39260 —
CUF0193 V2059-5800-553 2035 24890 30890 37450 44930 53420
40 22460 27980 34020 40950 —
CUF0208 V2571-7300-553 2535 30300 36730 45390 54390 64610
40 27110 33680 41310 49630 —
CUF0217 V3084-7300-553 3035 35650 44010 53150 62950 74670
40 32320 40010 48440 58080 —
CUF0219A V3293-9600-554 3035 38980 48670 59290 71370 85060
40 34820 43670 53960 65170 —
CUF0225 Z35106-9600-554 3535 45540 56250 68000 80610 95750
40 41260 51050 61810 74170 —
48Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
dens
ing
Uni
ts
R404A - Low Temperature (415/3/50)RealcoldStock No.
Model Nom Hp
Amb Temp
Capacity In Watts Price $Excl. Gst
-35ºC -30ºC -25ºC -20ºC -15ºC
CUF0014 A16-550-352.6 135 820 1100 1420 1800 2210
40 700 970 1280 1610 2010
CUF0024 A157-550-352.6 1.535 1000 1340 1760 2190 2710
40 860 1190 1560 1970 2450
CUF0044 B210-550-352 235 1390 1850 2370 2990 3660
40 1240 1660 2130 2680 3320
CUF0055 D211-650-352 235 1610 2140 2790 3530 4390
40 2910 1900 2490 3160 3890
CUF0066 D213-650-352 235 1980 2590 3300 4150 5080
40 3650 2340 3000 3720 4610
CUF0082 D315-1000-402 335 2280 3230 4100 5050 6290
40 2070 2920 3700 4570 5570
CUF0107 Q420-1200-402 435 2870 3810 4950 6240 7670
40 2550 3370 4410 5650 6960
CUF0120 Q525-1400-402 535 3530 4760 6150 7770 9630
40 3110 4190 5520 6990 8670
CUF0128 Q528-1700-402 5.535 4220 5620 7270 9100 11210
40 3740 5020 6450 8200 10120
CUF0137 Q533-1700-402 5.535 5180 6670 8420 10430 12620
40 4600 6020 7610 9450 11440
CUF0149 Q736-2200-402 7.535 6240 8080 10140 12510 15240
40 5570 7260 9130 11290 13780
CUF0151 S842-2800-502 835 6610 8850 11320 14130 17330
40 5760 7790 10140 12680 15570
CUF0163 S1052-3900-552 1035 8710 11260 14200 17600 21420
40 7810 10190 12910 16080 19600
CUF0174 S1556-3900-552 1535 9540 12460 15670 19570 23930
40 8390 11100 14200 17620 21840
CUF0187 V1559-4900-552 1535 10050 13070 16540 20600 25120
40 8880 11820 15060 18820 22990
CUF0199 V1571-4900-552 1535 11790 15360 19250 23970 29240
40 10360 13680 17450 21580 26680
CUF0214 V2084-5800-553 2035 12970 17150 22080 27530 33730
40 21520 15390 19830 24700 30230
CUF0218 V2593-5800-553 2535 13230 17920 23170 29240 36220
40 11520 15580 20590 26130 32500
CUF0223 Z25106-7300-553 2535 15900 21440 28090 35560 44190
40 14150 19170 24920 32030 39890
CUF0226 Z30126-7300-553 3035 18520 24780 31880 40140 46640
40 16410 21800 28520 35990 44590
CONDENSING UNITSFRASCOLD SEMI-HERMETIC
49Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
dens
ing
Uni
tsCONDENSING UNITS
FRASCOLD SEMI-HERMETIC
R134a - Med Temperature (415/3/50)RealcoldStock No.
Model Nom Hp
Amb Temp
Capacity In Watts Price $Excl. Gst
-15ºC -10ºC -5ºC 0ºC 5ºC 10ºC
CUF0014 A16-550-352.6 135 1330 1690 2100 2580 3120 3710
40 1230 1570 1960 2420 2910 3500
CUF0024 A157-550-352.6 1.535 1700 2150 2670 3250 3910 4660
40 1560 2000 2490 3040 3670 4390
CUF0044 B210-550-352 235 2350 2990 3730 4560 5480 6520
40 2170 2770 3470 4250 5120 6110
CUF0055 D211-650-352 235 2640 3390 4260 5270 6410 7620
40 2430 3130 3950 4900 5920 7040
CUF0066 D213-650-352 235 3180 4020 5000 6090 7280 8600
40 2910 3720 4600 5620 6780 8080
CUF0082 D315-1000-402 335 3670 4720 5890 7250 8800 10500
40 3370 4370 5480 6770 8190 9790
CUF0107 Q420-1200-40-2 435 5000 6360 7950 9730 11750 14000
40 4600 5930 7450 9130 11120 13180
CUF0120 Q525-1400-40-2 535 6420 8080 9890 12060 14460 17190
40 5980 7510 9280 11330 13590 16170
CUF0137 Q533-1700-402 5.535 7760 9780 12100 14750 17680 20820
40 7260 9160 11340 13730 16570 19500
CUF0149 Q736-2200-402 7.535 9330 11840 14670 17760 21200 25010
40 8700 11030 13720 16770 20060 23690
CUF0150 S842-2200-402 835 10730 13610 16890 20590 24880 29810
40 9830 12560 15680 19190 23280 28010
CUF0162 S1052-2800-502 1035 12720 15930 19680 23840 28600 33990
43 11830 14890 18300 22370 26860 31950
CUF0173 S1556-2800-502 1535 14170 17760 21790 26410 31690 37400
40 13170 16590 20400 24770 29740 35140
CUF0186 V1559-3900-552 1535 15430 19340 23900 29170 35230 42140
40 14240 18080 22410 27410 33160 39450
CUF0198 V1571-3900-552 1535 18120 22650 27930 33800 40490 48060
40 16850 21170 26180 31720 38040 45200
CUF0211 V2084-4900-552 2035 19320 24910 31000 38270 46290 55350
40 17880 22930 28850 35720 43290 51880
CUF0212 V2593-4900-552 2535 23100 28920 35700 43240 51840 61180
40 21500 27050 33480 40610 48740 57550
CUF0220 Z25106-5800-553 2535 24330 30930 38650 47190 56880 67820
40 34060 28600 35480 43740 52800 63070
CUF0226 Z30126-7300-553 3035 29830 37970 47480 58500 70620 84330
40 27490 35150 44110 54510 65970 79000
50Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
dens
ing
Uni
ts
CONDENSING UNITSFRASCOLD SEMI-HERMETIC
240/1/50 Technical DataRealcoldStock No.
Compressor Condenser Unit Dimensions Connection WeightKg
dB(A)3mtrModel Hp Disp
M3hrMra
Model Fans Ph Amps (ea) L/Sec W D H Drw
no. Liq Suc
CUF0013-1PH A016 1 5.5 6.2 RAC550-352 2x 350 1 0.70 1652 860 640 460 1 3/8 5/8 57 60
CUF0014-1PH A016 1 5.5 6.2 RAC550-352.6 2x 350 1 0.70 1250 860 640 460 1 3/8 5/8 57 53
CUF0024-1PH A157 1.5 6.9 7.9 RAC650-352.6 2x 350 1 0.70 1250 860 640 460 1 3/8 5/8 58 53
CUF0028-1PH A157 1.5 6.9 7.9 RAC650-352 2x 350 1 0.70 1652 860 640 460 1 3/8 5/8 58 60
CUF0044-1PH B210 2 9.8 11.7 RAC550-352 2x 350 1 0.70 1652 860 640 460 1 3/8 3/4 65 61
415/3/50 Technical DataRealcoldStock No.
Compressor Condenser Unit Dimensions Connection WeightKg
dB(A)3mtrModel Hp Disp
M3hrMra
Model Fans Ph Amps (ea) L/Sec W D H Drw
no. Liq Suc
CUF0013 A016 1 5.5 3.5 RAC550-352 2x 350 1 0.70 1652 860 640 460 1 3/8 5/8 57 60
CUF0014 A016 1 5.5 3.5 RAC550-352.6 2x 350 1 0.70 1250 860 640 460 1 3/8 5/8 57 53
CUF0024 A157 1.5 6.9 4.5 RAC550-352.6 2x 350 1 0.70 1250 860 640 460 1 3/8 5/8 58 53
CUF0028 A157 1.5 6.9 4.5 RAC650-352 2x 350 1 0.70 1652 860 640 460 1 3/8 5/8 58 60
CUF0044 B210 2 9.8 6.7 RAC550-352 2x 350 1 0.70 1652 860 640 460 1 3/8 3/4 65 61
CUF0049 B210 2 9.8 6.7 RAC1000-402 2x 400 1 0.95 2444 1060 660 565 1 3/8 3/4 68 65
CUF0055 D211 2 11.3 7.1 RAC650-352 2x 350 1 0.70 1652 860 640 565 1 3/8 7/8 72 61
CUF0058 D211 2 11.3 7.1 RAC1000-402 2x 400 1 0.95 2444 1060 660 565 1 3/8 7/8 78 65
CUF0066 D213 2 13.8 7.1 RAC650-352 2x 350 1 0.70 1652 860 640 460 1 3/8 7/8 72 61
CUF0074 D313 3 13.8 8.8 RAC1400-402 2x 400 1 0.95 2444 1060 760 660 1 3/8 1-1/8 74 65
CUF0082 D315 3 15.3 10.0 RAC1000-402 2x 400 1 0.95 2444 1060 760 660 1 1/2 1-1/8 75 65
CUF0086 D315 3 15.3 10.0 RAC1400-402 2x 400 1 0.95 2444 1060 760 660 1 1/2 1-1/8 75 65
CUF0103 D418 4 17.9 12.5 RAC1700-402 2x 400 1 0.95 2444 1060 660 675 1 1/2 1-1/8 84 66
CUF0107 Q420 4 19.8 10.1 RAC1200-402 2x 400 1 0.95 2444 1060 660 675 1 1/2 1-1/8 122 65
CUF0112 Q521 4 21.2 11.6 RAC1700-402 2x 400 1 0.95 2444 1060 660 675 1 1/2 1-1/8 133 65
CUF0120 Q525 5 24.7 12.7 RAC1400-402 2x 400 1 0.95 2444 1060 760 660 1 1/2 1-1/8 122 65
CUF0124 Q525 5 24.7 12.7 RAC2200-402 2x 400 1 0.95 2444 1275 1100 740 1 1/2 1-1/8 139 65
CUF0128 Q528 5.5 27.9 14.0 RAC1700-402 2x 400 1 0.95 2444 1060 660 675 1 1/2 1-3/8 133 66
CUF0137 Q533 5.5 32.7 14.4 RAC1700-402 2x 400 1 0.95 2444 1060 660 675 1 1/2 1-3/8 122 66
CUF0133 Q728 7.5 27.9 17.6 RAC2800-502 2x 500 3 0.95 3470 1475 1100 800 2 1/2 1-3/8 139 70
CUF0145 Q733 7.5 32.7 20 RAC2800-502 2x 500 3 0.95 3470 1475 1100 800 2 1/2 1-3/8 140 70
CUF0149 Q736 7.7 35.9 19.4 RAC2200-402 2x 400 1 0.95 2444 1275 1100 740 2 1/2 1-3/8 139 66
CUF0150 S842 8 41.3 20.3 RAC2200-402 2x 400 1 0.95 2444 1275 1100 740 2 5/8 1-3/8 165 66
51Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
dens
ing
Uni
tsCONDENSING UNITS
FRASCOLD SEMI-HERMETIC
• Ratings based on 20k suction superheat, 3k subcooling• For 43deg ambient ratings multiply 40deg by 0.95• Please refer to pages 63-65 for fitted optional accessories. • All noise level ratings are ‘free field’ based at a distance of 3meters and are given as a guide only.
415/3/50 Technical DataRealcoldStock No.
Compressor Condenser Unit Dimensions Connection WeightKg
dB(A)3mtrModel Hp Disp
M3hrMra
Model Fans Ph Amps (ea) L/Sec W D H Drw
no. Liq Suc
CUF0151 S842 8 41.3 20.3 RAC2800-502 2x 500 3 0.95 3470 1475 1100 800 2 5/8 1-3/8 185 70
CUF0157 S1242 12 41.3 22.4 RAC3900-552 2x 550 3 0.95 3470 1475 1100 1070 2 5/8 1-3/8 215 75
CUF0162 S1052 10 51.5 24.5 RAC2800-502 2x 500 3 0.95 3470 1475 1100 800 2 5/8 1-3/8 205 70
CUF0163 S1052 10 51.5 24.5 RAC3900-552 2x 550 3 1.15 4715 1475 1100 1070 2 5/8 1-3/8 215 72
CUF0169 S1552 15 51.5 32.4 RAC4900-552 2x 550 3 1.15 4715 1475 1100 1070 2 5/8 1-5/8 224 72
CUF0173 S1556 15 56.0 30.7 RAC2800-502 2x 500 3 0.95 3470 1475 1100 800 2 5/8 1-5/8 210 71
CUF0174 S1556 15 56.0 30.7 RAC3900-552 2x 550 3 1.15 4715 1475 1100 1070 2 5/8 1-5/8 224 75
CUF0181 S2056 20 56.0 38.4 RAC4900-552 2x 550 3 1.15 4715 1475 1100 1070 2 7/8 1-5/8 235 75
CUF0186 V1559 15 58.5 31.1 RAC3900-552 2x 550 3 1.15 4715 1475 1100 1070 2 7/8 1-5/8 254 75
CUF0187 V1559 15 58.5 31.1 RAC4900-552 2x 550 3 1.15 4715 1475 1100 1070 2 7/8 1-5/8 265 75
CUF0193 V2059 20 58.5 35.3 RAC5800-553 3x 550 3 1.15 7072 2200 1100 1070 3 7/8 1-5/8 270 77
CUF0198 V1571 15 70.8 32.2 RAC3900--552 2x 550 3 1.15 4715 1475 1100 1070 2 7/8 1-5/8 255 75
CUF0199 V1571 15 106.1 32.2 RAC4900-552 2x 550 3 1.15 4715 1475 1100 1070 2 7/8 1-5/8 265 75
CUF0208 V2571 30 70.8 43.5 RAC7300-553 3x 550 3 1.15 7072 2200 1100 1070 3 7/8 2-1/8 272 77
CUF0211 V2084 20 83.8 42.6 RAC4900-552 2x 550 3 1.15 4715 1475 1100 1070 2 7/8 1-5/8 265 75
CUF0214 V2084 20 83.8 42.6 RAC5800-553 3x 550 3 1.15 7072 2200 1100 1070 3 7/8 1-5/8 281 77
CUF0212 V2593 25 93.1 52.3 RAC4900-552 2x 550 3 1.15 4715 1475 1100 1070 2 7/8 2-1/8 275 76
CUF0218 V2593 25 93.1 52.3 RAC5800-553 3x 550 3 1.15 7072 2200 1100 1070 3 7/8 2-1/8 298 77
CUF0217 V3084 30 83.8 49.2 RAC7300-553 3x 550 3 1.15 7072 2200 1100 1070 3 7/8 2-1/8 320 77
CUF0219A V3293 32 93.1 53.1 RAC9600-554 4x 550 3 1.15 9430 2200 1470 1570 4 7/8 2-1/8 340 78
CUF0220 Z2593 25 93.1 52.3 RAC5800-553 3x 550 3 1.15 7072 2200 1100 1070 3 7/8 2-1/8 298 80
CUF0223 Z25106 25 106.2 53.6 RAC7300-553 3x 550 3 1.15 7072 2200 1100 1070 3 7/8 2-1/8 330 81
CUF0225 Z35106 35 106.2 60.2 RAC9600-554 4x 550 3 1.15 9430 2200 1470 1570 4 7/8 2-1/8 345 81
CUF0226 Z30126 30 106.2 55.7 RAC7300-553 3x 550 3 1.15 3 2200 1100 1070 3 7/8 2-1/8 340 82
52Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
dens
ing
Uni
ts
CONDENSING UNITSTECHNICAL DATA
Drawing 1
Drawing 2
Drawing 3
Drawing 4
53Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
dens
ing
Uni
tsCONDENSING UNITS
REMOTE SEMI-HERMETIC
FRASCOLD range of Remote semi-Hermetic condensing units are manufactured in our factory in Australia. They include internationally accepted Frascold semi-hermetic compressors, which are ideally suited for todays conscientious environment. The large range extends from 1hp through to 70 hp with capacities from 3kw through to 130kw operating on R404A @ -5deg SST.All our units are built to Australian standards and include only high quality components. This ensures reliability, high performance and trouble free operation all year round.
Features & InclusionsCompressor sets up to 20hp include standard:
• Frascold Semi-Hermetic reciprocating compressor• Liquid receiver with Rotalock valves• Crankcase heater• Electronic motor protection• Auto reset dual pressure control• Ester oil charge (mineral oil charge on request)
All units have the above components as standard with the larger 20 to 70hp range having these additional components fitted.
• High pressure oil pump and oil filter• DELTA-P oil pressure safety control• Discharge gas high temperature protection
A huge range of optional extras can be fitted at your request and include:
• Liquid line drier and sightglass• Liquid line solenoid valve• Capacity control head • Oil separator (with internal or external oil floats)• Suction line accumulator• Electrical panels• Extra pressure controls or transducers• Fan cycling control• Fan speed controller
Please contact your nearest Realcold branch or one of our applications engineers for other configurations that you may require. With the utilisation of world class manufacturing technology, Realcold can offer flexible design and fast turn around times.
MODEL DESIGNATION
RECEIVERM
OD
ELV
COM
PRESSOR
SERIES
20M
OTO
R HP
59D
ISPLACEM
ENT
M³/H
R15-30
RECEIVER MO
DEL
54Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
dens
ing
Uni
ts
CONDENSING UNITSREMOTE SEMI-HERMETIC
R404A - Med Temperature (415/3/50)RealcoldStock No.
Model Nom Hp
Cond Temp
Capacity In Watts Price $Excl. Gst
-15ºC -10ºC -5ºC 0ºC 5ºC
CUF0503-1PH A16-RBF550 140 2380 2930 3560 4290 5110
50 1940 2410 2940 3540 4220
CUF0503 A16-RBF550 140 2380 2930 3560 4290 5110
50 1940 2410 2940 3540 4220
CUF0506-1PH A157-RBF550 1.540 3030 3740 4560 5500 6580
50 2470 3080 3770 4560 5450
CUF0506 A157-RBF550 1.540 3030 3740 4560 5500 6580
50 2470 3080 3770 4560 5450
CUF0512-1PH B210-RBF550 240 4140 5130 6280 7600 9110
50 3390 4200 5150 6250 7510
CUF0512 B210-RBF550 240 4140 5130 6280 7600 9110
50 3390 4200 5150 6250 7510
CUF0515 D211-RBF550 240 4900 6090 7470 9050 10860
50 3920 4900 6030 7340 8850
CUF0521 D313-RBF650 340 5760 7150 8760 10600 12710
50 4710 5840 7150 8660 10390
CUF0524 D315-RBF650 340 6830 8370 10150 12190 14530
50 5550 6800 8240 9910 11830
CUF0530 D418-RBF650 340 8090 9880 11930 14270 16920
50 7390 9010 10880 13020 15420
CUF0533 Q521/075-4 540 9040 11260 13790 16630 19830
50 7160 9000 11080 13430 16070
CUF0539 Q525/075-4 540 10700 13260 16230 19640 23540
50 8640 10740 13160 15970 19190
CUF0542 Q728/075-4 7.540 12550 15480 18860 22730 27130
50 10210 12620 15410 18620 22280
CUF0547 Q733/075-4 7.540 14500 17870 21770 26250 31370
50 11800 14570 17780 21470 25700
CUF0554 S1242/5-15 1240 17570 21890 26870 32570 39040
50 14020 17630 21830 26670 32200
CUF0560 S1552/5-15 1540 23730 28990 35080 42130 50270
50 19640 24050 29130 35000 41800
55Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
dens
ing
Uni
tsCONDENSING UNITS
REMOTE SEMI-HERMETIC
R404A - Med Temperature (415/3/50)RealcoldStock No.
Model Nom Hp
Cond Temp
Capacity In Watts Price $Excl. Gst
-15ºC -10ºC -5ºC 0ºC 5ºC
CUF0566 S2056/5-15 2040 26160 32040 38680 46480 55440
50 21470 26470 32090 38680 46210
CUF0572 V2059/15-30 2040 26670 32060 39490 47990 57600
50 20490 25850 32070 39180 47180
CUF0578 V2571/15-30 2540 30900 38530 47410 57610 69170
50 24810 31160 38540 46990 56520
CUF0584 V3084/15-30 3040 37580 46560 56940 68860 82440
50 30380 37830 46490 56490 67970
CUF0586 V3293/30-50 3040 39880 50070 61870 75420 90860
50 31850 40270 50090 61450 74480
CUF0588 Z35106-ALH64 3540 47530 58990 72350 87770 105420
50 38310 47670 58650 71430 86180
CUF0593 Z40126-ALH64 4040 55320 68850 84560 102620 123220
50 44350 55400 68350 83360 100630
CUF0600 Z50154-ALH64 5040 67520 83950 102950 124650 149070
50 54600 68330 84190 102280 122550
CUF0602 W60187-ALH130 6040 83770 104190 128040 155700 187530
50 67540 84220 103740 126460 152760
CUF0605 W70206-ALH130 7040 91990 113970 139390 168600 201960
50 74800 93150 114390 138900 167010
56Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
dens
ing
Uni
ts
CONDENSING UNITSREMOTE SEMI-HERMETIC
R404A - Low Temperature (415/3/50)RealcoldStock No.
Model Nom Hp
Cond Temp
Capacity In Watts Price $Excl. Gst
-35ºC -30ºC -25ºC -20ºC -15ºC
CUF0503-1PH A16-RBF550 140 810 1120 1480 1900 2380
50 590 860 1170 1530 1940
CUF0503 A16-RBF550 140 810 1120 1480 1900 2380
50 590 860 1170 1530 1940
CUF0506-1PH A157-RBF550 1.540 1030 1420 1880 2410 3030
50 750 1090 1480 1940 2470
CUF0506 A157-RBF550 1.540 1030 1420 1880 2410 3030
50 750 1090 1480 1940 2470
CUF0512-1PH B210-RBF550 240 1480 1970 2580 3290 4140
50 1210 1620 2110 2700 3390
CUF0512 B210-RBF550 240 1480 1970 2580 3290 4140
50 1210 1620 2110 2700 3390
CUF0515 D211-RBF550 240 1690 2300 3030 3890 4900
50 1260 1780 2390 3090 3920
CUF0518 D213-RBF550 240 2140 2830 3670 4660 5830
50 1750 2320 3010 3820 4800
CUF0524 D315-RBF650 340 — 3450 4400 5520 6830
50 — 2800 3580 4490 5550
CUF0532 Q420/075-4 440 3020 4040 5280 6740 8460
50 2340 3200 4230 5470 6940
CUF0539 Q525/075-4 540 3710 5050 6640 9510 10700
50 2900 3950 5290 6840 8640
CUF0541 Q528/075-4 540 4440 5960 7760 9870 12330
50 3440 4700 6190 7930 9960
CUF0543 Q533/075-4 5.540 5510 7230 9250 11630 14400
50 4450 5870 7540 9500 11800
CUF0544 Q736/075-4 7.540 6640 8660 11040 13810 17030
50 5520 6910 8890 11200 13900
CUF0551 S842/5-15 840 6860 9280 12080 15330 19080
50 5230 7240 9550 12220 15300
CUF0557 S1052/5-15 1040 9150 11920 15080 18770 23100
50 7140 9590 12330 15470 19150
57Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
dens
ing
Uni
tsCONDENSING UNITS
REMOTE SEMI-HERMETIC
R404A - Low Temperature (415/3/50)RealcoldStock No.
Model Nom Hp
Cond Temp
Capacity In Watts Price $Excl. Gst
-35ºC -30ºC -25ºC -20ºC -15ºC
CUF0563 S1556/5-15 1540 9750 12940 16650 20980 25990
50 7530 10290 13480 17210 21480
CUF0569 V1559/15-30 1540 10350 13610 17370 21860 27050
50 7980 10770 13990 17820 22240
CUF0575 V1571/15-30 1540 12030 15930 20480 25810 31900
50 9310 12680 16590 21150 26300
CUF0581 V2084/15-30 2040 13500 17990 23310 29560 36830
50 10750 14290 18490 23450 29270
CUF0583 V2593/15-30 2540 13680 18780 24810 31860 40070
50 10080 14320 19310 25150 31960
CUF0587 Z25106-ALH64 2540 16530 22510 29670 38150 48060
50 12870 17730 23570 30520 38710
CUF0590 Z30126-ALH64 3040 19490 26320 34480 44100 55350
50 15100 20660 27280 35120 44320
CUF0597 Z40154-ALH64 4040 26720 35280 45340 56970 70340
50 20810 28200 36840 46770 58120
CUF0602 W60187-ALH130 6040 — 39400 51750 66410 83770
50 — 30800 41200 53320 67540
CUF0605 W70206-ALH130 7040 — 43190 56960 73110 91990
50 — 33660 45420 59010 74800
58Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
dens
ing
Uni
ts
CONDENSING UNITSREMOTE SEMI-HERMETIC
R134a - Med Temperature (415/3/50)RealcoldStock No.
Model Nom Hp
Cond Temp
Capacity In Watts Price $Excl. Gst
-15ºC -10ºC -5ºC 0ºC 5ºC 10ºC
CUF0503-1PH A16-RBF550 140 1320 1690 2120 2620 3210 3880
50 1110 1440 1830 2280 2800 3400
CUF0503 A16-RBF550 140 1320 1690 2120 2620 3210 3880
50 1110 1440 1830 2280 2800 3400
CUF0506-1PH A157-RBF550 1.540 1710 2190 2760 3420 4190 5070
50 1440 1880 2380 2970 3650 4440
CUF0506 A157-RBF550 1.540 1710 2190 2760 3420 4190 5070
50 1440 1880 2380 2970 3650 4440
CUF0512-1PH B210-RBF550 240 2390 3090 3910 4870 5960 7220
50 2000 2620 3340 4180 5150 6260
CUF0512 B210-RBF550 240 2390 3090 3910 4870 5960 7220
50 2000 2620 3340 4180 5150 6260
CUF0515 D211-RBF550 240 2670 3480 4440 5570 6870 8340
50 2200 2910 3760 4740 5870 7150
CUF0518 D213-RBF550 240 3260 4180 5270 6560 8060 9790
50 2740 3550 4500 5620 6940 8450
CUF0524 D315-RBF650 340 3680 4760 6030 7500 9210 11180
50 3030 4010 5140 6460 7980 9740
CUF0532 Q420/075-4 440 4680 6170 7980 10130 12650 15590
50 3810 5100 6680 8560 10780 13360
CUF0539 Q525/075-4 540 6520 8240 10280 12680 15470 18710
50 5570 7130 8940 11050 13520 16390
CUF0541 Q528/075-4 540 6620 8520 10810 13510 16670 20310
50 5590 7260 9270 11640 14410 18510
CUF0543 Q533/075-4 5.540 7850 10040 12600 15580 19050 24190
50 6770 8690 10910 13500 16510 20970
CUF0544 Q736/075-4 7.540 9470 12090 15130 18590 22480 26890
50 8150 10500 13230 16360 19890 23910
CUF0551 Q842/5-15 840 11040 14200 17950 22370 27540 33620
50 9090 11930 15330 19350 24060 29650
CUF0557 S1052/5-15 1040 13260 16800 20960 25840 31530 38110
50 11310 14490 18190 22510 27540 33360
CUF0563 S1556/5-15 1540 14730 18660 23250 28590 34810 42200
50 12530 16060 20170 24940 30490 37010
CUF0569 V1559/15-30 1540 15560 19750 24660 30350 36980 44850
50 13190 16960 21350 26440 32350 39310
CUF0575 V1571/15-30 1540 18510 23420 29140 35840 43640 52900
50 15740 20140 25280 31260 38230 46370
59Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
dens
ing
Uni
tsCONDENSING UNITS
REMOTE SEMI-HERMETIC
R134a - Med Temperature (415/3/50)RealcoldStock No.
Model Nom Hp
Cond Temp
Capacity In Watts Price $Excl. Gst
-15ºC -10ºC -5ºC 0ºC 5ºC 10ºC
CUF0581 V2084/15-30 2040 19510 25350 32270 40390 49810 60840
50 16470 21520 27530 34600 42850 52570
CUF0583 V2593/15-30 2540 23750 30110 37570 46260 56370 68330
50 20250 25980 32700 40460 49470 60030
CUF0587 Z25106-ALH64 2540 24580 31830 40480 50660 62530 76480
50 20700 26790 34090 42740 52880 64880
CUF0590 Z30126-ALH64 3040 30140 39000 49480 61740 75370 92620
50 25150 32880 42040 52800 65340 80100
CUF0597 Z40154-ALH64 4040 36690 47240 59810 74620 91890 112200
50 30690 39800 50700 63600 78720 96620
CUF0602 W60187-ALH130 6040 46000 58860 73990 91600 111920 135160
50 38360 49790 63220 78870 96980 117750
CUF0605 W70206-ALH130 7040 49600 64530 82290 103150 127370 155210
50 41990 54930 70360 88540 109740 134200
60Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
dens
ing
Uni
ts
CONDENSING UNITSREMOTE SEMI-HERMETIC
240/1/50 Technical DataRealcoldStock No.
Unit Model Compressor Dimensions (mm) Connection WeightKg
dB(A)3mtr
MODEL HPDISP M3hr
MRALRA DOL
LRA P/W
L (A) D (B) H (C) In Out
CUF0503-1PH A016-RBF550 A016 1 5.5 6.2 13.6 DOL 550 430 400 3/8 1/2 56 38
CUF0506-1PH A157-RBF550 A157 1.5 6.9 7.9 20.6 DOL 550 430 400 3/8 1/2 56 39
CUF0512-1PH B210-RBF550 B210 2 9.8 11.7 35.9 DOL 550 430 420 3/8 1/2 58 42
415/3/50 Technical DataRealcoldStock No.
Unit Model Compressor Dimensions (mm) Connection WeightKg
dB(A)3mtr
MODEL HPDISP M3hr
MRALRA DOL
LRA P/W
L (A) D (B) H (C) In Out
CUF0503 A016-RBF550 A016 1 5.5 3.5 13.6 DOL 550 430 400 3/8 1/2 56 38
CUF0506 A157-RBF550 A157 1.5 6.9 4.5 20.6 DOL 550 430 400 3/8 1/2 56 39
CUF0512 B210-RBF550 B210 2 9.8 6.7 35.9 DOL 550 430 420 3/8 1/2 58 42
CUF0515 D211-RBF550 D211 2 11.3 7.1 24.9 DOL 550 430 420 3/8 1/2 65 48
CUF0518 D213-RBF550 D213 2 13.8 7.1 24.9 DOL 550 430 420 3/8 1/2 65 50
CUF0521 D313-RBF650 D313 3 13.8 8.8 43.7 DOL 650 460 445 3/8 1/2 69 50
CUF0524 D315-RBF650 D315 3 15.3 10 43.7 DOL 650 460 445 3/8 1/2 69 50
CUF0530 D418-RBF650 D418 4 17.9 12.5 52.0 DOL 650 460 445 3/8 1/2 71 51
CUF0532 Q420/075-4 Q420 4 19.8 10.1 53.0 DOL 1000 800 600 7/8 7/8 132 52
CUF0533 Q521/075-4 Q521 5 21.2 11.6 63.1 DOL 1000 800 600 7/8 7/8 137 53
CUF0539 Q525/075-4 Q525 5 24.7 12.7 63.1 DOL 1000 800 600 7/8 7/8 137 53
CUF0541 Q528/075-4 Q528 5.5 27.9 14.0 63.1 DOL 1000 800 600 7/8 7/8 137 55
CUF0543 Q533/075-4 Q533 5.5 32.7 14.4 63.1 DOL 1000 800 600 7/8 7/8 137 55
CUF0542 Q728/075-4 Q728 7.5 27.9 17.6 87.3 DOL 1000 800 600 7/8 7/8 137 55
CUF0547 Q733/075-4 Q733 7.5 32.7 20.0 87.3 DOL 1000 800 600 7/8 7/8 137 56
CUF0544 Q736/075-4 Q736 7.7 35.9 19.4 87.3 DOL 1000 800 600 7/8 7/8 137 56
CUF0551 S842/5-15 S842 8 41.3 20.3 90.3 52.7 1000 800 700 1-1/8 7/8 182 57
CUF0557 S1052/5-15 S1051 10 51.5 24.2 87.6 53.9 1000 800 700 1-1/8 7/8 185 59
CUF0554 S1242/5-15 S1242 12 41.3 22.4 102 59.1 1000 800 700 1-1/8 7/8 185 59
CUF0560 S1552/5-15 S1551 15 51.5 31.5 117.1 74.8 1000 800 700 1-1/8 7/8 192 59
CUF0563 S1556/5-15 S1556 15 56.0 30.7 117.1 74.8 1000 800 700 1-1/8 7/8 195 61
CUF0566 S2056/5-15 S2056 20 56.0 38.4 136.2 87.5 1000 800 700 1-1/8 7/8 197 61
CUF0569 V1559/15-30 V1559 15 58.5 31.1 117.1 74.8 1300 800 800 1-1/8 7/8 245 60
CUF0575 V1571/15-30 V1571 15 70.8 31.0 117.1 74.8 1300 800 800 1-1/8 7/8 245 61
61Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
dens
ing
Uni
tsCONDENSING UNITS
REMOTE SEMI-HERMETIC
• All noise level ratings are 'free field' based at a distance of 3meters and are given as a guide only.• Refer to next page for dimensional drawings.
415/3/50 Technical DataRealcoldStock No.
Unit Model Compressor Dimensions (mm) Connection WeightKg
dB(A)3mtr
MODEL HPDISP M3hr
MRALRA DOL
LRA P/W
L (A) D (B) H (C) In Out
CUF0569 V1559/15-30 V1559 15 58.5 31.1 117.1 74.8 1300 800 800 1-1/8 7/8 245 60
CUF0575 V1571/15-30 V1571 15 70.8 31.0 117.1 74.8 1300 800 800 1-1/8 7/8 245 61
CUF0572 V2059/15-30 V2059 20 58.5 35.3 136.2 87.5 1300 800 800 1-1/8 7/8 250 60
CUF0578 V2571/15-30 V2571 25 70.8 43.5 202.7 104.1 1300 800 800 1-1/8 7/8 258 61
CUF0581 V2084/15-30 V2084 20 83.8 42.6 145.2 89.9 1300 800 800 1-1/8 7/8 258 67
CUF0583 V2593/15-30 V2593 25 93.1 52.3 202.7 104.1 1300 800 800 1-1/8 7/8 265 66
CUF0584 V3084/15-30 V3084 30 83.8 49.2 186.2 118.3 1300 800 800 1-1/8 7/8 260 64
CUF0586 V3293/15-30 V3293 30 93.1 53.1 239.2 144.5 1300 800 800 1-1/8 7/8 265 64
CUF0587 Z25106-ALH64 Z25106 25 106.2 53.6 202.7 118.3 1390 940 880 1-3/8 1-3/8 298 61
CUF0590 Z30126-ALH64 Z30126 30 125.7 55.7 186.2 118.3 1390 940 880 1-3/8 1-3/8 306 69
CUF0588 Z35106-ALH64 Z35106 35 106.2 60.2 239.2 144.5 1390 940 880 1-3/8 1-3/8 300 64
CUF0593 Z40126-ALH64 Z40126 40 125.7 71.9 273.0 159.2 1390 940 880 1-3/8 1-3/8 317 67
CUF0596 Z40154-ALH64 Z40154 40 154.4 77.9 273.0 159.2 1390 940 880 1-3/8 1-3/8 324 71
CUF0599 Z50154-ALH64 Z50154 50 154.4 90.4 321.4 188.6 1390 940 880 1-3/8 1-3/8 330 67
CUF0602 W60187-ALH130 W60187 60 186.1 103.5 455 326 1600 800 1070 1 3/8 1 3/8 468 70
CUF0605 W70206-ALH130 W70206 70 205.8 116.8 548 390 1600 800 1070 1 3/8 1 3/8 482 73
Custom Design & Build Service
Realcold offer a complete design and build facility for chilled water packages.
To assist our Technical Sales Staff in providing the best solution for your chiller and/or process needs please use the following information guide when forwarding your request. This will help ensure the best possible design and quotation is offered to you. Please do not hesitate to contact our staff should you have any queries or wish to discuss possible design options:
Ambient conditions - °C Application - What is chiller to be used for? Buffer tank required - Yes / No, Size? Condensing - Water or Air cooled? Coolant pumps - Primary and / or secondary Coolant type - Water, Glycol, oil, other Cooling Capacity - kW Electrical - Level of electrical controls and safeties required. Expected load variation - Max and minimum load percentage Heat Exchanger type - Plate, Shell and Tube, Open type Hygiene requirements - SS pipe, fittings, tank etc Refrigerant - R404A, R507, R22, R134a, R407C, etc Required flow rates - L/s, m³/hr, Kg/s Required Temperature - Coolant supply and return temperatures Unit location - Indoor or outdoor?
62Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
dens
ing
Uni
ts
CONDENSING UNITSTECHNICAL DATA
A, B & D SERIES
2 Cylinder Models
S, V & Z SERIES
4 & 6 Cylinder Models
W-SERIES
8 Cylinder Models
63Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
dens
ing
Uni
tsCONDENSING UNITS
ACCESSORIES
Liquid Line Assembly - Medium & Low Temp ModelsIncludes Drier, Liquid Moisture Indicator, Solenoid Valve, Pipework Fitted
RealcoldStock No.
Description Price$ Excl. Gst
C5901 1/4" Liquid Line c/w Sight Glass - 052 Drier
C5903 3/8" Liquid Line c/w Sight Glass - 083 Drier
C5904 1/2" Liquid Line c/w Sight Glass - 084 Drier
C5906 1/2" Liquid Line c/w Sight Glass - 164 Drier
C5908 5/8" Liquid Line c/w Sight Glass - 415 Drier
C5909 5/8" Liquid Line c/w Sight Glass and 1 Core Drier
C5911 7/8" Liquid Line c/w Sight Glass and 2 Core Drier
C5912 1 1/8" Liquid Line c/w Sight Glass and 2 Core Drier
C5913 1 3/8" Liquid Line c/w Sight Glass and 3 Core Drier
Oil Separator AssemblyIncludes Oil Separator, Vibration Eliminator, Pipework Fitted
RealcoldStock No.
Line Size Suits HP Price$ Excl. Gst
C5931 1/2" 1 HP to 1 1/2 HP
C5932 5/8" 2 HP to 3 HP
C5933 7/8" 4 HP to 5 HP
C5934 1 1/8" 7 1/2 HP to 20 HP
C5935 1 3/8" 25 HP to 35 HP
C5936 1 5/8" 40 HP to 50 HP
C5937 2 1/8" 50 HP to 60 HP
C5938 2 5/8" 60 HP to 70 HP
Suction Line AssemblyIncludes Accumulator, Vibration Eliminator and Pipework Fitted
RealcoldStock No.
Line Size Suits Models Price$ Excl. Gst
C5945 5/8" Assy 1.5 HP
C5946 3/4" Assy 2 HP Medium Temp Only
C5947 7/8" Assy 2 HP Low Temp Only
C5948 1 1/8" Assy 3 HP to 6 HP
C5949 1 3/8" Assy 7.5 HP to 15 HP
64Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
dens
ing
Uni
ts
Suction Line Refillable Filter AssemblyIncludes Refillable Filter, Accumulator, Vibration Eliminator and Pipework Fitted
RealcoldStock No.
Line Size Suits Models Price$ Excl. Gst
C5956 1 3/8" Assy (c/w one core drier) 6 HP to 10 HP
C5957 1 5/8" Assy (c/w one core drier) 15 HP to 20 HP
C5958 2 1/8" Assy (c/w one core drier) 25 HP to 35 HP
C5959 2 5/8" Assy (c/w two core drier) 40 HP to 50 HP
C5961 3 1/8" Assy (c/w two core drier) 50 HP to 70 HP
Suction Line Filter Fitted AssemblyIncludes Filter and Pipework Fitted
RealcoldStock No.
Line Size Suits Models Price$ Excl. Gst
C5966 5/8" Assy 1.5 HP
C5968 7/8" Assy 2 HP
C5969 1 1/8" Assy 3 HP to 5 HP
C5970 1 3/8" Assy 7.5 HP to 10 HP
Oil Return Line SightglassRealcoldStock No.
Line Size Suits HP Price$ Excl. Gst
C5995 3/8” sweat. All models 3/4 HP to 10 HP
Pressure ControlsRealcoldStock No.
Description Price$ Excl. Gst
C5987 LP Pump Down Control - Fitted
C5988 HP Condenser Fan Control - Fitted
C5989 HP/LP Control Fitted
CONDENSING UNITSACCESSORIES
Capacity Control - Unloader Head
RealcoldStock No.
Frascold Item No.
Item Suits Series Price$ Excl. GST
C5222 T00SK250150 Capacity Control Q (Coil Included) Q series
C5221 T00SK220100 Capacity Control S (Coil Included) S series
C5225 T00SK220200 Capacity Control V-Z-W (Coil Included) V, Z, W series
Start Unloader Head
RealcoldStock No.
Frascold Item No.
Item Suits Series Price$ Excl. GST
C5226 T00SK250150 Start Unloader Q (Coil Included) S Series
C5226A T00SK250100 Start Unloader S (Coil Included) S Series
C5227 T00SK250200 Start Unloader V-Z-W (Coil Included) V, Z, W Series
* Can be used in conjuction with PWS to significantly reduce compressor starting current.
65Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
dens
ing
Uni
tsCONDENSING UNITS
ACCESSORIES
Crankcase Heaters
RealcoldStock No.
Frascold Item No.
Item Suits Series Compressor
Price$ Excl. GST
R0553 T00CH13RIC 50 Watt Crankcase Heater, Fitted A, B & D
R0552 T00CH1RIC 70 Watt Crankcase Heater, Fitted F, Q, S & T
R0555 T00CH9RIC 150 Watt Crankcase Heater, Fitted MK2 V, Z & W
MiscellaneousRealcoldStock No.
Description Price$ Excl. Gst
R0316 Rubber Mounts 40 x 40 mm, 2 - 3HP
Head Cooling Fans (240/1/50)
RealcoldStock No.
Frascold Item No.
Suits Series Compressor
Price$ Excl. GST
C5805 SZ-FM1 A, B, D & F
C5803 SZ-FM2S/001 S Series
C5804 SZ-FM2V/001 V Series
C5806 SZ-FM3/001 Z Series
C5807 SZ-FM4/001 W Series
C5810 SZ-FM9 Q Series
Please contact Realcold for information and availability of Frascold spares and accessories not listed
Oil Cooler / Seperator
RealcoldStock No.
Description Type Price$ Excl. GST
C5824 Water Cooled Oil Cooler SZ-WOC1
C5826 Water Cooled Oil Cooler SZ-WOC2
C5828 Water Cooled Oil Cooler SZ-WOC3
C5830 Air Cooled Oil Cooler SZ-AOC1
C5832 Air Cooled Oil Cooler SZ-AOC2
C5834 Air Cooled Oil Cooler SZ-AOC3
C5836 Remote Oil Separator TOOWK200
C5838 Remote Oil Separator TOOWK201
C5840 Remote Oil Separator TOOWK202
66Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Hea
t Exc
hang
ers
Doucette Heat ExchangersNominal capacities kWs at +5°C SST 5.5K of subcooling for below heat exchangers
RealcoldStock No.
Model Description Price$ Excl. GSTNom.
HPR22 R404A R134a Connection Sizes Dimensions
Dia. x Length (mm)
Liq. Vol. cm³
Suction Liquid
F0045 SLHE 1 1 4.52 3.17 4.09 5⁄8" SW 3⁄8" SW 28 344 44
F0046 SLHE 1.1/2 1 1⁄2 6.30 4.20 5.83 7⁄8" SW 3⁄8" SW 35 363 52
F0048 SLHE 3 3 8.21 4.69 7.59 1 1⁄8" SW 1⁄2" SW 42 375 58
F0049 SLHE 5 5 14.51 9.67 12.85 1 3⁄8" SW 5⁄8" SW 54 356 255
F0050 SLHE 7.1/2 7 1⁄2 17.79 11.43 15.19 1 5⁄8" SW 5⁄8" SW 54 425 306
• Doucette Heat Exchangers are all copper construction, suitable for all refrigerants. Type L copper fluted suction tubes.• Single and multiple tube configurations to reduce velocity and pressure drop. High temperature brass brazed. UL listed
Working Principle:
Wilchwitzer Thermo-Technik (WTT) consists of a pack of pressed stainless steel plates which are brazed together with 99.9% copper in a vacuum furnace. When assembling the pack every alternate plate is rotated by 180° to produce two separate flow channels in which the heat exchange media flow in opposite directions. All contact points are joined by brazing. This process makes it possible to achieve very high mechanical strength, i.e. high pressure resistance. The corrugated plates generate high turbulence during fluid through put, which promotes efficient heat exchange even with a low flow rate.
Applications: WTT can be utilized for a wide range of gaseous and non clogging liquid media: Water; Oil; Glycol; Freons. Typical applications include:
• Floor Heating • Condensers and evaporators in Chillers & Heatpumps• Industrial processes• Hydraulic oil cooling• Heat Recovery• Desuperheaters
Advantages:• Compact unit, low weight • High operational temperatures and high workings pressures.• Less space required • SUS316 (AISI 316) (W-1.4401) stainless steel for effective corrosion resistance.• No gaskets, no leaks • Easy installation and replacement, low maintenance requirements.• High heat transmission rate
HEAT EXCHANGERSDOUCETTE
67Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Hea
t Exc
hang
ers
Evaporator Coils Units Feature:
• Compact size to cooling capacity ratio.
• Excellent surface area to cooling capacity ratio.
• Hinged drain pan with “thumbscrews” for easy access to defrost elements and condensate pan.
• Hinged side covers with “thumbscrews” for easy access to TEV, heater safety Klixon.
• Motors and defrost elements are all pre-wired to terminal connections in the electrical box.
• 1/4” access port on all coils is a standard feature for checking in-coil pressures and setting up superheats.
• Flat 4 mm slotted mounting brackets for very quick easy installation. Top of evaporator coil only 4 mm from ceiling panel easy to seal for hygiene purposes.
• Standard 4.2 mm fin spacing on medium temperature and low temperature models, easily inter-changed from low to medium temperature applications. Alternative fin spacing available on request.
• Light weight construction, even the large capacity coils are easy to lift.
Rondo Two Fan HCT
Rondo Single FanHDT
HEAT EXCHANGERS HC EVAPORATORS
Nomenclature
H CT - 25 2 - 3R x 6F - E HC Heat Exchangers Electric Defrost (if required) Model CT - Ceiling Type Fins per Inch Fan Diameter (cm) No. of Coil Rows (2, 3 or 4) No. of Fans 1 to 4
68Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Hea
t Exc
hang
ers
Rondo - Medium Temperature EvaporatorsRealcoldStock No.
Model Capacity in Watts @ 6KTD
Fans(mm)
Air Volume(M³ / Sec)
Dimensions (mm) Weight (Kg)
Connections Price$ Excl. GST
R404A R134a W D H Liquid Suction
W4001 Ron - 140-A 630 599 1 x 250 0.21 455 440 120 4 3/8 3/8
W4000 Ron - 240-A 800 761 1 x 250 0.19 455 440 120 4.5 3/8 3/8
W4002 Ron - 340-A 950 904 1 x 250 0.21 455 440 145 5 1/2 1/2
W4008 Ron - 440-A 1080 1028 1 x 250 0.22 455 440 170 5.5 1/2 1/2
W4009 Ron - 500-A 1660 1579 2 x 250 0.37 760 430 175 8.3 1/2 1/2
W4010 Ron - 700-A 2060 1960 2 x 250 0.43 760 430 230 9.4 1/2 5/8
W4012 Ron - 900-A 3380 3216 2 x 300 0.92 1060 530 230 14 1/2 5/8
W4013 Ron - 1100-A 4040 3844 2 x 300 1.05 1060 530 265 15.4 1/2 3/4
W4014 Ron - 1300-A 4640 4414 2 x 300 0.94 1060 530 265 17.4 1/2 3/4
HEAT EXCHANGERSHC EVAPORATORS
Technical DataRealcoldStock No.
Model Nom Cap R404A (kW) kW @ ITD = 6K Te = -5°C
Coil Surface Area (m2)
Air Flow Frost Free (m3/s)
Face Velocity (m/s)
Mass (kg)
Fans No x Dia
Liquid connection mm (inch)
Suction connection mm (inch)
TX Valve Type INT/EXT
Elect. efrost 230V (kW)
W4001 Rondo140-A 0.63 2.0 0.2 2.2 4.0 1x250 9.5 (3/8) 9.5 (3/8) INT n/a
W4000 Rondo240-A 0.80 3.0 0.2 2.0 4.5 1x250 9.5 (3/8) 9.5 (3/8) INT n/a
W4002 Rondo340-A 0.95 3.7 0.2 1.8 5.0 1x250 12.7 (1/2) 12.7 (1/2) EXT n/a
W4008 Rondo440-A 1.08 4.5 0.2 1.6 5.5 1x250 12.7 (1/2) 12.7 (1/2) EXT n/a
W4009 Rondo500-A 1.66 6.2 0.4 1.9 8.3 2x250 12.7 (1/2) 12.7 (1/2) EXT n/a
W4010 Rondo700-A 2.06 8.3 0.4 1.7 9.4 2x250 12.7 (1/2) 15.9 (5/8) EXT n/a
W4012 Rondo900-A 3.38 10.2 0.9 2.9 14.0 2x300 12.7 (1/2) 15.9 (5/8) EXT n/a
W4013 Rondo1100-A 4.04 12.8 1.1 2.6 15.4 2x300 12.7 (1/2) 19.05 (3/4) EXT n/a
W4014 Rondo1300-A 4.64 17.0 0.9 2.4 17.4 2x300 12.7 (1/2) 19.05 (3/4) EXT n/a
Correction Factors
Suction Temperatures -10°C -5°C 0°C +5°C
Correction Factor 0.97 1.00 1.03 1.05
• Ideal for large glass door display cabinets, supermarkets display cabinets, small coolrooms and flower rooms
• Unique radial coil design provides a large surface area, offering a compact unit to cooling capacity ratio
• Radial design provides 180° air-flow distribution and prevents warm air pockets.
• Durable white ABS plastic construction is tough and maintenance free
• Reliable EBM fan motors fitted and pre-wired to electrical box
69Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Hea
t Exc
hang
ers
HEAT EXCHANGERSHC EVAPORATORS
HCT Series - Medium Temp - No Defrost (250 mm Fans)RealcoldStock No.
Model Capacity in Watts @ 6KTD
Dimensions (mm) Connections Drain (BSP)
Weight (Kg)
Charge R404A (Kg)
Price$ Excl. GST
404a 134a W D H Inlet Outlet
Low Silotte Ceiling Mount
W4600 HCT-251-2R 410 390 425 450 175 9.5 9.5 12.7 5.5 0.6
W4603 HCT-252-2R 970 923 750 450 175 9.5 9.5 12.7 11 1.0
W4605 HCT-252-3R 1210 1151 750 450 175 9.5 9.5 12.7 16 1.3
W4607 HCT-253-3R 1820 1732 750 450 175 9.5 12.5 20 20 1.9
W4609 HCT-254-3R 2430 2312 1400 450 175 9.5 12.5 20 30 2.0
Technical DataRealcoldStock No.
Model Nom Cap R404A (kW) kW @ ITD = 6K Te = -5°C
Coil Surface Area (m2)
Air Flow Frost Free (m3/s)
Face Velocity (m/s)
Mass (kg)
Air Throw (m)
Liquid connection mm (inch)
Suction connection mm (inch)
TX Valve Type INT/EXT
Elect. efrost 230V (kW)
Heater Element Kit No.
Low Silotte Ceiling Mount
W4600 HCT-251-2R 0.41 1.0 0.1 2.9 5.2 10 9.5 (3/8) 9.5 (3/8) INT n/a n/a
W4603 HCT-252-2R 0.97 2.0 0.3 2.9 7.8 10 12.7 (1/2) 12.7 (1/2) EXT n/a n/a
W4605 HCT-252-3R 1.21 3.0 0.2 2.5 8.4 9 12.7 (1/2) 12.7 (1/2) EXT n/a n/a
W4607 HCT-253-3R 1.82 4.5 0.4 2.5 11.7 9 12.7 (1/2) 12.7 (1/2) EXT n/a n/a
W4609 HCT-254-3R 2.43 6.0 0.5 2.5 15 9 12.7 (1/2) 12.7 (1/2) EXT n/a n/a
Note: Partial Defrost Element Kits are available upon request.
Correction Factors
Suction Temperatures -10°C -5°C 0°C +5°C
Correction Factor 0.97 1.00 1.03 1.05
• Suitable for large glass door display cabinets, supermarkets display cabinets, small coolrooms and freezer rooms
• Compact, low profile design with optimised dimensions
• Reliable EBM fan motors fitted and pre-wired to electrical box
• Robust aluminium casing with easy clean, hygienic white powder coated finish
70Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Hea
t Exc
hang
ers
HEAT EXCHANGERSHC EVAPORATORS
HCT Series - Low Temp - Full Electric Defrost (250 mm Fans)RealcoldStock No.
Model Capacity in Watts @ 6KTD
Dimensions (mm) Connections Drain (BSP)
Weight (Kg)
Charge R404A (Kg)
Price$ Excl. GST
404a W D H Inlet Outlet
Capacity at -24SST / 6KTD R404A
W4604 HCT-252-2RE 830 750 450 175 9.5 9.5 20 11 1
W4606 HCT-252-3RE 1040 750 450 175 9.5 12.5 20 16 1.3
W4608 HCT-253-3RE 1570 1075 450 175 9.5 12.5 20 16 1.9
W4610 HCT-254-3RE 2090 1400 450 175 9.5 12.5 20 16 2.3
Technical DataRealcoldStock No.
Model Nom Cap R404A (kW) kW @ ITD = 6K Te = -5°C
Coil Surface Area (m2)
Air Flow Frost Free (m3/s)
Face Velocity (m/s)
Mass (kg)
Air Throw (m)
Liquid connection mm (inch)
Suction connection mm (inch)
TX Valve Type INT/EXT
Elect. efrost 230V (kW)
Heater Element Kit No.
Capacity at -24SST / 6KTD R404A
W4604 HCT-252-2RE 0.83 2.0 0.3 2.9 7.8 10 12.7 (1/2) 12.7 (1/2) EXT 0.36 W7100
W4606 HCT-252-3RE 1.04 3.0 0.2 2.5 8.4 9 12.7 (1/2) 12.7 (1/2) EXT 0.36 W7100
W4608 HCT-253-3RE 1.57 4.5 0.4 2.5 11.7 9 12.7 (1/2) 12.7 (1/2) EXT 0.54 W7102
W4610 HCT-254-3RE 2.09 6.0 0.5 2.5 15 9 12.7 (1/2) 12.7 (1/2) EXT 0.72 W7103
Correction Factors
Suction Temperatures -35°C -30°C -24°C -20°C -15°C
Correction Factor 0.92 0.97 1.00 1.02 1.03
• Suitable for large glass door display cabinets, supermarkets display cabinets, small coolrooms & freezer rooms
• Compact, low profile design with optimised dimensions
• Reliable EBM fan motors fitted and pre-wired to electrical box
• Defrost elements and temperature termination thermostat are easily accessed and come pre-wired to terminal box on all low temp models
• Robust aluminium casing with easy clean, hygienic white powder coated finish
71Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Hea
t Exc
hang
ers
HEAT EXCHANGERSHC EVAPORATORS
HSR Series - Medium Temperature Evaporators (300 mm Fans)RealcoldStock No.
Model Capacity in Watts @ 6KTD
Fans(mm)
Air Volume(M³ / Sec)
Dimensions (mm) Weight (Kg)
Connections Price$ Excl. GST
R404A R134a W D H Liquid Suction
W5052H HSR - 301 - 3R 1810 1722 1 x 300 0.48 874 577 476 17 1/2 5/8
W5004H HSR - 301 - 4R 2090 1988 1 x 300 0.44 874 577 476 18 1/2 7/8
W5006H HSR - 301 - 5R 2290 2179 1 x 300 0.41 874 577 476 19 1/2 7/8
W5010H HSR - 302 - 3R 3650 3473 2 x 300 0.96 1376 577 476 26 1/2 7/8
W5012H HSR - 302 - 4R 4220 4015 2 x 300 0.88 1376 577 476 29 1/2 7/8
W5014H HSR - 302 - 5R 4600 4376 2 x 300 0.82 1376 577 476 31 1/2 7/8
W5016H HSR - 303 - 3R 5490 5223 3 x 300 1.44 1884 577 476 35 1/2 1.1/8
W5020H HSR - 303 - 5R 6910 6574 3 x 300 1.23 1884 577 476 42 1/2 1.1/8
W5018H HSR - 304 - 3R 7350 6993 4 x 300 1.92 2380 577 476 44 1/2 1.1/8
W5022H HSR - 304 - 4R 8500 8087 4 x 300 1.76 2380 577 476 49 5/8 1.1/8
Technical DataRealcoldStock No.
Model Nom Cap R404A (kW) kW @ ITD = 6K Te = -5°C
Coil Surface Area (m2)
Air Flow Frost Free (m3/s)
Face Velocity (m/s)
Mass (kg)
Air Throw (m)
Liquid connection mm (inch)
Suction connection mm (inch)
TX Valve Type INT/EXT
Elect. efrost 230V (kW)
Heater Element Kit No.
W5052H HSR-301-3R 1.81 9.0 0.5 2.5 17 11 12.7 (1/2) 15.9 (5/8) EXT n/a W7160
W5004H HSR-301-4R 2.09 12.0 0.4 2.3 18 10 12.7 (1/2) 22.2 (7/8) EXT n/a W7160
W5006H HSR-301-5R 2.29 15.0 0.4 2.2 19 9 12.7 (1/2) 22.2 (7/8) EXT n/a W7161
W5010H HSR-302-3R 3.65 18.0 1.0 2.5 26 11 12.7 (1/2) 22.2 (7/8) EXT n/a W7162
W5012H HSR-302-4R 4.22 24.0 0.9 2.3 29 10 12.7 (1/2) 22.2 (7/8) EXT n/a W7162
W5014H HSR-302-5R 4.6 30.0 0.8 2.2 31 9 12.7 (1/2) 22.2 (7/8) EXT n/a W7164
W5016H HSR-303-3R 5.49 27.0 1.4 2.5 35 11 12.7 (1/2) 28.5 (1.1/8) EXT n/a W7163
W5020H HSR-303-5R 6.91 45.0 1.2 2.2 42 9 12.7 (1/2) 28.5 (1.1/8) EXT n/a W7165
W5018H HSR-304-3R 7.35 36.0 1.9 2.5 44 11 12.7 (1/2) 28.5 (1.1/8) EXT n/a W7167
W5022H HSR-304-4R 8.5 48.0 1.8 2.3 49 10 15.9 (5/8) 28.5 (1.1/8) EXT n/a W7167
Note: Partial Defrost Element Kits are available upon request.
Correction Factors
Suction Temperatures -10°C -5°C 0°C +5°C
Correction Factor 0.97 1.00 1.03 1.05
• Aesthetically pleasing construction provides a professional finish to any coolroom
• Robust aluminium casing with easy clean, hygienic white powder coated finish
• High efficiency EBM external rotor fan motors come pre-wired to electrical box
• Intermediate drip tray prevents air-flow bypass and condensation
• Corrosion resistant stainless steel fasteners used throughout construction
72Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Hea
t Exc
hang
ers
HEAT EXCHANGERSHC EVAPORATORS
HSR Series - Realcold Low Temperature Evaporators (300 mm Fans)RealcoldStock No.
Model Capacity in Watts @ 6KTD
Fans(mm)
Air Volume(M³ / Sec)
Dimensions (mm) Weight (Kg)
Connections Price$ Excl. GST
R404A W D H Liquid Suction
W5054H HSR - 301 - 3RE 1560 1 x 300 0.48 874 577 476 17 1/2 5/8
W5056H HSR - 301 - 4RE 1800 1 x 300 0.44 874 577 476 18 1/2 7/8
W5058H HSR - 301 - 5RE 1970 1 x 300 0.41 874 577 476 19 1/2 7/8
W5062H HSR - 302 - 3RE 3140 2 x 300 0.96 1376 577 476 26 1/2 7/8
W5064H HSR - 302 - 4RE 3630 2 x 300 0.88 1376 577 476 29 1/2 7/8
W5066H HSR - 302 - 5RE 3960 2 x 300 0.82 1376 577 476 31 1/2 7/8
W5068H HSR - 303 - 3RE 4720 3 x 300 1.44 1884 577 476 35 1/2 1.1/8
W5070H HSR - 303 - 4RE 5450 3 x 300 1.32 1884 577 476 39 1/2 1.1/8
W5072H HSR - 303 - 5RE 5940 3 x 300 1.23 1884 577 476 42 1/2 1.1/8
Technical DataRealcoldStock No.
Model Nom Cap R404A (kW) kW @ ITD = 6K Te = -5°C
Coil Surface Area (m2)
Air Flow Frost Free (m3/s)
Face Velocity (m/s)
Mass (kg)
Air Throw (m)
Liquid connection mm (inch)
Suction connection mm (inch)
TX Valve Type INT/EXT
Elect. efrost 230V (kW)
Heater Element Kit No.
W5054H HSR-301-3RE 1.56 9.0 0.5 2.5 17 11 12.7 (1/2) 15.9 (5/8) EXT 1.2 W7160
W5056H HSR-301-4RE 1.80 12.0 0.4 2.3 18 10 12.7 (1/2) 22.2 (7/8) EXT 1.2 W7160
W5058H HSR-301-5RE 1.97 15.0 0.4 2.2 19 9 12.7 (1/2) 22.2 (7/8) EXT 1.5 W7161
W5062H HSR-302-3RE 3.14 18.0 1.0 2.5 26 11 12.7 (1/2) 22.2 (7/8) EXT 2.2 W7162
W5064H HSR-302-4RE 3.63 24.0 0.9 2.3 29 10 12.7 (1/2) 22.2 (7/8) EXT 2.2 W7162
W5066H HSR-302-5RE 3.96 30.0 0.8 2.2 31 9 12.7 (1/2) 22.2 (7/8) EXT 2.8 W7164
W5068H HSR-303-3RE 4.72 27.0 1.4 2.5 35 11 12.7 (1/2) 28.5 (1.1/8) EXT 3.2 W7163
W5070H HSR-303-4RE 5.45 36.0 1.3 2.3 39 10 12.7 (1/2) 28.5 (1.1/8) EXT 3.2 W7163
W5072H HSR-303-5RE 5.94 45.0 1.2 2.2 42 9 12.7 (1/2) 28.5 (1.1/8) EXT 4.0 W7165
• Robust aluminium casing with easy clean, hygienic white powder coated finish
• High efficiency EBM external rotor fan motors come pre-wired to electrical box
• Intermediate drip tray prevents air-flow bypass and condensation
• Corrosion resistant stainless steel fasteners used throughout construction
• Defrost elements and temperature termination thermostat pre-wired to terminal box on all low temp models
• Defrost elements incased in copper sleeves offer; superior heater reliability, easy replacement and reduces frost formation on fans and ceiling
Correction Factors
Suction Temperatures -35°C -30°C -24°C -20°C -15°C
Correction Factor 0.92 0.97 1.00 1.02 1.03
73Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Hea
t Exc
hang
ers
HEAT EXCHANGERSHC EVAPORATORS
HSR Series - Medium Temperature Evaporators (350 mm Fans)RealcoldStock No.
Model Capacity in Watts @ 6KTD
Fans(mm)
Air Volume(M³ / Sec)
Dimensions (mm) Weight (Kg)
Connections Price$ Excl. GST
R404A R134a W D H Liquid Suction
HSR Range
W5024H HSR - 352 - 4R 6540 6222 2 x 350 1.42 1455 577 476 38 1/2 1.1/8
W5026H HSR - 352 - 6R 7700 7326 2 x 350 1.30 1455 577 476 44 1/2 1.1/8
W5028H HSR - 353 - 4R 9830 9352 3 x 350 2.13 1972 577 476 51 5/8 1.1/8
W5030H HSR - 353 - 6R 11580 11017 3 x 350 1.95 1972 577 476 61 5/8 1.1/8
W5032H HSR - 354 - 4R 13140 12501 4 x 350 2.84 2540 577 476 65 5/8 1.3/8
W5034H HSR - 354 - 6R 15440 14690 4 x 350 2.60 2540 577 476 78 5/8 1.3/8
Technical DataRealcoldStock No.
Model Nom Cap R404A (kW) kW @ ITD = 6K Te = -5°C
Coil Surface Area (m2)
Air Flow Frost Free (m3/s)
Face Velocity (m/s)
Mass (kg)
Air Throw (m)
Liquid connection mm (inch)
Suction connection mm (inch)
TX Valve Type INT/EXT
Elect. efrost 230V (kW)
Heater Element Kit No.
HSR Range
W5024H HSR-352-4R 6.54 32.0 1.4 2.7 38 15 12.7 (1/2) 28.5 (1.1/8) EXT n/a W7175
W5026H HSR-352-6R 7.70 48.0 1.3 2.4 44 15 12.7 (1/2) 28.5 (1.1/8) EXT n/a W7179
W5028H HSR-353-4R 9.83 48.0 2.1 2.7 51 16 15.9 (5/8) 28.5 (1.1/8) EXT n/a W7181
W5030H HSR-353-6R 11.58 72.0 2.0 2.4 61 16 15.9 (5/8) 34.9 (1.3/8) EXT n/a W7187
W5032H HSR-354-4R 13.14 64.0 2.8 2.7 65 17 15.9 (5/8) 34.9 (1.3/8) EXT n/a W7185
W5034H HSR-354-6R 15.44 97.0 2.6 2.4 78 17 15.9 (5/8) 34.9 (1.3/8) EXT n/a W7191
Note: Partial Defrost Element Kits are available upon request.
• Robust aluminium casing with easy clean, hygienic white powder coated finish
• High efficiency EBM external rotor fan motors come pre-wired to electrical box
• Intermediate drip tray prevents air-flow bypass and condensation
• Corrosion resistant stainless steel fasteners used throughout construction
• Defrost elements and temperature termination thermostat pre-wired to terminal box on all low temp models
• Defrost elements incased in copper sleeves offer; superior heater reliability, easy replacement and reduces frost formation on fans and ceiling
Correction Factors
Suction Temperatures -35°C -30°C -24°C -20°C -15°C
Correction Factor 0.92 0.97 1.00 1.02 1.03
74Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Hea
t Exc
hang
ers
HEAT EXCHANGERSHC EVAPORATORS
HSR Series - Low Temperature Evaporators (350 mm Fans)RealcoldStock No.
Model Capacity in Watts @ 6KTD
Fans(mm)
Air Volume(M³ / Sec)
Dimensions (mm) Weight (Kg)
Connections Price$ Excl. GST
R404A W D H Liquid Suction
HCT Range
W5076H HSR - 352 - 6RE 6620 2 x 350 1.30 1455 577 476 44 1/2 1.1/8
W5080H HSR - 353 - 6RE 9960 3 x 350 1.95 1972 577 476 61 5/8 1.1/8
W5082H HSR - 354 - 4RE 11300 4 x 350 2.84 2540 577 476 65 5/8 1.3/8
W5084H HSR - 354 - 6RE 13280 4 x 350 2.60 2540 577 476 78 5/8 1.3/8
Technical DataRealcoldStock No.
Model Nom Cap R404A (kW) kW @ ITD = 6K Te = -5°C
Coil Surface Area (m2)
Air Flow Frost Free (m3/s)
Face Velocity (m/s)
Mass (kg)
Air Throw (m)
Liquid connection mm (inch)
Suction connection mm (inch)
TX Valve Type INT/EXT
Elect. efrost 230V (kW)
Heater Element Kit No.
HCT Range
W5076H HSR-352-6RE 6.62 48.0 1.3 2.4 44 15 12.7 (1/2) 28.5 (1.1/8) EXT 5.0 W7179
W5080H HSR-353-6RE 9.96 72.0 2.0 2.4 61 16 15.9 (5/8) 34.9 (1.3/8) EXT 7.5 W7187
W5082H HSR-354-4RE 11.30 64.0 2.8 2.7 65 17 15.9 (5/8) 34.9 (1.3/8) EXT 8.0 W7185
W5084H HSR-354-6RE 13.28 97.0 2.6 2.4 78 17 15.9 (5/8) 34.9 (1.3/8) EXT 10.0 W7191
Note: Partial Defrost Element Kits are available upon request.
• Robust aluminium casing with easy clean, hygienic white powder coated finish
• High efficiency EBM external rotor fan motors come pre-wired to electrical box
• Intermediate drip tray prevents air-flow bypass and condensation
• Corrosion resistant stainless steel fasteners used throughout construction
• Defrost elements and temperature termination thermostat pre-wired to terminal box on all low temp models
• Defrost elements incased in copper sleeves offer; superior heater reliability, easy replacement and reduces frost formation on fans and ceiling
Correction Factors
Suction Temperatures -35°C -30°C -24°C -20°C -15°C
Correction Factor 0.92 0.97 1.00 1.02 1.03
75Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Hea
t Exc
hang
ers
HEAT EXCHANGERSHC EVAPORATORS
HDD Series - Low Temperature Evaporators (350 mm Fans)RealcoldStock No.
Model Capacity in Watts @ 6KTD
Fans(mm)
Air Volume(M³ / Sec)
Dimensions (mm) Weight (Kg)
Connections Price$ Excl. GST
R404A R134a W D H Liquid Suction
HDD Range
W5500H HDD - 351 - 4R 4070 3872 1 x 350 0.75 954 577 1261 26 1/2 7/8
W5502H HDD - 352 - 3R 7040 7763 2 x 350 1.50 1495 577 1261 42 1/2 1.1/8
W5504H HDD - 353 - 3R 10580 10066 3 x 350 2.34 2035 577 1261 53 5/8 1.1/8
W5508H HDD - 353 - 6R 14080 13396 3 x 350 2.10 2035 577 1261 69 5/8 1.1/8
Technical DataRealcoldStock No.
Model Nom Cap R404A (kW) kW @ ITD = 6K Te = -5°C
Coil Surface Area (m2)
Air Flow Frost Free (m3/s)
Face Velocity (m/s)
Mass (kg)
Air Throw (m)
Liquid connection mm (inch)
Suction connection mm (inch)
TX Valve Type INT/EXT
Elect. efrost 230V (kW)
Heater Element Kit No.
HDD Range
W5500H HDD-351-4R 4.07 17.3 0.8 2.6 26 4 12.7 (1/2) 22.2 (7/8) EXT n/a W7130
W5502H HDD-352-3R 7.04 26.0 1.6 2.7 38 4 12.7 (1/2) 28.5 (1.1/8) EXT n/a W7132
W5504H HDD-353-3R 10.58 39.0 2.3 2.7 53 4 15.9 (5/8) 28.5 (1.1/8) EXT n/a W7134
W5508H HDD-353-6R 14.08 78.0 2.1 2.4 69 4 15.9 (5/8) 34.9 (1.3/8) EXT n/a W7136
Note: Partial Defrost Element Kits are available upon request.
• Robust aluminium casing with easy clean, hygienic white powder coated finish
• High efficiency EBM external rotor fan motors come pre-wired to electrical box
• Intermediate drip tray prevents air-flow bypass and condensation
• Corrosion resistant stainless steel fasteners used throughout construction
• Defrost elements and temperature termination thermostat pre-wired to terminal box on all low temp models
• Defrost elements incased in copper sleeves offer; superior heater reliability, easy replacement and reduces frost formation on fans and ceiling
Correction Factors
Suction Temperatures -35°C -30°C -24°C -20°C -15°C
Correction Factor 0.92 0.97 1.00 1.02 1.03
76Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Hea
t Exc
hang
ers
HEAT EXCHANGERSHC EVAPORATORS
HDD Series - Low Temperature Evaporators (350 mm Fans)RealcoldStock No.
Model Capacity in Watts @ 6KTD
Fans(mm)
Air Volume(M³ / Sec)
Dimensions (mm) Weight (Kg)
Connections Price$ Excl. GST
R404A W D H Liquid Suction
HDD Range
W4630 HDD-351-4RE 3500 0.75 0.75 954 577 1261 26 1/2 7/8
W4632 HDD-352-3RE 6050 1.56 1.56 1495 577 1261 38 1/2 1.1/8
W4634 HDD-353-3RE 9100 2.40 2.34 2035 577 1261 53 5/8 1.1/8
W4636 HDD-353-6RE 12110 2.22 2.10 2035 577 1261 69 5/8 1.3/8
Technical DataRealcoldStock No.
Model Nom Cap R404A (kW) kW @ ITD = 6K Te = -5°C
Coil Surface Area (m2)
Air Flow Frost Free (m3/s)
Face Velocity (m/s)
Mass (kg)
Air Throw (m)
Liquid connection mm (inch)
Suction connection mm (inch)
TX Valve Type INT/EXT
Elect. efrost 230V (kW)
Heater Element Kit No.
HDD Range
W4630 HDD-351-4RE 3.50 17.3 0.8 2.6 26 4 12.7 (1/2) 22.2 (7/8) EXT 2.5 W7130
W4632 HDD-352-3RE 6.05 26.0 1.6 2.7 38 4 12.7 (1/2) 28.5 (1.1/8) EXT 3.0 W7132
W4634 HDD-353-3RE 9.10 39.0 2.3 2.7 53 4 15.9 (5/8) 28.5 (1.1/8) EXT 4.5 W7134
W4636 HDD-353-6RE 12.11 78.0 2.1 2.4 69 4 15.9 (5/8) 34.9 (1.3/8) EXT 9.0 W7136
Note: Partial Defrost Element Kits are available upon request.
• Robust aluminium casing with easy clean, hygienic white powder coated finish
• High efficiency EBM external rotor fan motors come pre-wired to electrical box
• Intermediate drip tray prevents air-flow bypass and condensation
• Corrosion resistant stainless steel fasteners used throughout construction
• Defrost elements and temperature termination thermostat pre-wired to terminal box on all low temp models
• Defrost elements incased in copper sleeves offer; superior heater reliability, easy replacement and reduces frost formation on fans and ceiling
Correction Factors
Suction Temperatures -35°C -30°C -24°C -20°C -15°C
Correction Factor 0.92 0.97 1.00 1.02 1.03
77Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Hea
t Exc
hang
ers
HEAT EXCHANGERSGUNTNER EVAPORATORS
GSF Series - Medium Temperature (400 mm Fans)RealcoldStock No.
Model Capacity in Watts @ -4°C SST/6KTD Price$ Excl. GSTR404A R134a
GSF Range
E0416 GSF040.2D/24-ANW 5800 5450
E0418 GSF040.2F/24-ANW 8000 7520
E0419 GSF040.2H/24-ANW 9500 8930
E0420 GSF040.2F/34-ANW 12200 11470
E0421 GSF040.2H/34-ANW 14800 13910
E0422 GSF040.2F/44-ANW 16000 15040
E0423 GSF040.2H/44-ANW 19100 17950
Technical Data
E0416 040.2D/24
E0418 040.2F/24
E0419 040.2H/24
E0420 040.2F/34
E0421 040.2H/34
E0422 040.2F/44
E0423 040.2H/44
Air Flowm³ / hr 6280 6140 5790 9210 8685 12280 11580
Ltr / sec 1744 1706 1608 2558 2413 3411 3217
Air Throw (m)Std Unit 14 13 13 14 13 14 14
Air Streamer * 28 26 25 28 27 29 27
Ebm Fan Motor 400 mm (230V)
No. of fans 2 2 2 3 3 4 4
Total Watts 460 460 460 690 690 920 920
Total Amps 2.1 2.1 2.1 3.2 3.2 4.2 4.2
Sound Data dB(A) @ 3 Metres 55 55 55 57 57 58 58
Surface Area m² 32.7 49.1 65.4 73.6 98.2 98.2 130.9
Fin Spacing mm 4 4 4 4 4 4 4
Expansion Valve Type EXT EXT EXT EXT EXT EXT EXT
Liquid Connection mm 16 16 22 22 22 22 22
Suction Connection mm 28 35 35 35 35 42 54
Dry Weight kg 60 69 75 98 107 128 141
Dimensions (width) mm 1770 1770 1770 2550 2550 3230 3230
* Air Streamer Optional
Correction Factors
Suction Temperatures -10°C -5°C 0°C +5°C
Correction Factor 0.97 1.00 1.03 1.05
• Aesthetically pleasing construction provides a professional finish to any coolroom. Robust aluminium casing with easy clean, hygienic white powder coated finish.
• High efficiency EBM external rotor fan motors fitted on all GSF models• Intermediate drip tray prevents air-flow bypass & condensation• Corrosion resistant stainless steel fasteners & mounting brackets• Hinged side covers for easy access to TX valve
78Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Hea
t Exc
hang
ers
HEAT EXCHANGERSGUNTNER EVAPORATORS
• Robust aluminium casing with easy clean, hygienic white powder coated finish
• High efficiency EBM external rotor fan motors fitted on all GSF models• Intermediate drip tray prevents air-flow bypass & condensation• Corrosion resistant stainless steel fasteners & mounting brackets• Hinged side covers for easy access to TX valve• Heaters encased in SS sleeves for greater reliability• 7 mm fin spacing reduces energy-robbing ice ups
Correction Factors
Suction Temperatures -40°C -35°C -30°C -24°C -20°C -15°C
Correction Factor 0.85 0.92 0.97 1.00 1.02 1.03
Technical Data
E0468L 040.2F/27
E0470L 040.2H/27
E0472L 040.2F/37
E0474L 040.2H/37
E0476L 040.2F/47
E0478L 040.2H/47
Air Volumem³ / hr 6420 6060 9630 9090 12840 12120
Ltr / sec 1783 1689 2675 2525 3567 3367
Air Throw (m)Std Unit 14 13 15 14 16 14
Air Streamer * 31 30 32 31 34 32
Ebm Fan Motor400 mm (230V)
No. of Fans 2 2 3 3 4 4
Total Watts 460 460 690 690 920 920
Total Amps 2.1 2.1 3.2 3.2 4.2 4.2
Sound Data dB(A) @ 3 Metres 55 55 57 57 58 58
Defrost Elements
CoilQty 3 4 3 4 3 4
Watts (ea) 1250 1250 1600 1600 2300 2300
Amps (ea) 5.4 5.4 7.0 7.0 10 10
PanQty 1 1 1 1 1 1
Watts (ea) 1200 1200 1800 1800 2200 2200
Amps (ea) 5.2 5.2 7.8 7.8 9.6 9.6
Surface Area m² 29.4 39.2 44.1 58.7 58.7 78.3
Fin Spacing mm 7 7 7 7 7 7
Expansion Valve Type EXT EXT EXT EXT EXT EXT
Liquid Connection mm 16 22 22 22 22 22
Suction Connection mm 28 35 35 35 42 54
Dry Weight kg 62 75 89 107 116 141
Dimensions (width) mm 1770 1770 2550 2550 3230 3230
* Air Streamer Optional
GSF Series - Low Temperature (400 mm Fans)RealcoldStock No.
Model Capacity in Watts @ -24°C SST/6KTD Price$ Excl. GSTR404A
E0468L GSF040.2F/27-ENW 5600
E0470L GSF040.2H/27-ENW 7000
E0472L GSF040.2F/37-ENW 8500
E0474L GSF040.2H/37-ENW 10300
E0476L GSF040.2F/47-ENW 11300
E0478L GSF040.2H/47-ENW 14100
79Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Hea
t Exc
hang
ers
HEAT EXCHANGERSGUNTNER EVAPORATORS
Technical Data
E0506 050.2F/24
E0508 050.2H/24
E0510 050.2F/34
E0515 050.2H/34
E0516 050.2F/44
E0518 050.2H/44
Air Flowm³ / hr 13380 12800 19680 18810 26240 25080
Ltr / sec 3717 3556 5467 5225 7289 6967
Air Throw (m)Std Unit 21 20 22 21 23 22
Air Streamer * 39 37 40 39 42 41
Ebm Fan Motor 500 mm (400V)
No. of fans 2 2 3 3 4 4
Total Watts 1240 1240 1860 1860 2480 2480
Total Amps 2.9 2.9 4.4 4.4 5.8 5.8
Sound Data dB(A) @ 3 Metres 57 57 60 60 61 61
Surface Area m² 101.0 134.7 151.6 202.1 202.1 269.4
Fin Spacing mm 4 4 4 4 4 4
Expansion Valve Type EXT EXT EXT EXT EXT EXT
Liquid Connection mm 22 22 22 28 28 35
Suction Connection mm 42 42 54 54 54 54
Dry Weight kg 130 156 190 227 247 296
Dimensions (width) mm 2470 2470 3570 3570 4570 4570
* Air Streamer Optional
GSF Series - Medium Temperature (500 mm Fans)RealcoldStock No.
Model Capacity in Watts @ -4°C SST/6KTD Price$ Excl. GSTR404A R134a
GSF Range
E0506 GSF050.2F/24.ANS 17000 16000
E0508 GSF050.2H/24.ANS 20100 18900
E0510 GSF050.2F/34.ANS 25600 24100
E0515 GSF050.2H/34.ANS 30400 28600
E0516 GSF050.2F/44.ANS 35100 33000
E0518 GSF050.2H/44.ANS 41900 39400
Correction Factors
Suction Temperatures -10°C -5°C 0°C +5°C
Correction Factor 0.97 1.00 1.03 1.05
• Aesthetically pleasing construction provides a professional finish to any coolroom. Robust aluminium casing with easy clean, hygienic white powder coated finish.
• High efficiency EBM external rotor fan motors fitted on all GSF models• Intermediate drip tray prevents air-flow bypass & condensation• Corrosion resistant stainless steel fasteners & mounting brackets• Hinged side covers for easy access to TX valve
80Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Hea
t Exc
hang
ers
HEAT EXCHANGERSGUNTNER EVAPORATORS
Correction Factors
Suction Temperatures -40°C -35°C -30°C -24°C -20°C -15°C
Correction Factor 0.85 0.92 0.97 1.00 1.02 1.03
• Robust aluminium casing with easy clean, hygienic white powder coated finish
• High efficiency EBM external rotor fan motors fitted on all GSF models• Intermediate drip tray prevents air-flow bypass & condensation• Corrosion resistant stainless steel fasteners & mounting brackets• Hinged side covers for easy access to TX valve• Heaters encased in SS sleeves for greater reliability• 7 mm fin spacing reduces energy-robbing ice ups
Technical DataE0533 050.2H/27
E0535 050.2J/27
E0538 050.2H/37
E0540 050.2J/37
E0543050.2H/47
Air Volumem³ / hr 13280 12880 19920 19320 26560
Ltr / sec 3689 3578 5533 5367 7378
Air Throw (m)Std Unit 22 21 23 22 24
Air Streamer * 42 41 44 43 46
Ebm Fan Motor500 mm (400V)
No. of Fans 2 2 3 3 4
Total Watts 1240 1240 1860 1860 2480
Total Amps 2.9 2.9 4.4 4.4 5.8
Sound Data dB(A) @ 3 Metres 59 59 60 60 61
Defrost Elements
CoilQty 5 6 5 6 5
Watts (ea) 1750 1750 2400 2400 3500
Amps (ea) 7.6 7.6 10.4 10.4 15.2
PanQty 2 2 2 2 2
Watts (ea) 1200 1200 1600 1600 1800
Amps (ea) 5.2 5.2 7.0 7.0 7.8
Surface Area m² 80.6 100.8 120.9 151.2 161.3
Fin Spacing mm 7 7 7 7 7
Expansion Valve Type EXT EXT EXT EXT EXT
Liquid Connection mm 28 22 28 28 28
Suction Connection mm 42 54 54 54 54
Dry Weight kg 143 153 209 221 270
Dimensions (width) mm 2470 2470 3570 3570 4570
* Air Streamer Optional
GSF Series - Low Temperature (500 mm Fans)RealcoldStock No.
Model Capacity in Watts @ -24°C SST/6KTD Price$ Excl. GSTR404A
E0533 GSF050.2H/27-ENS 15300
E0535 GSF050.2J/27-ENS 18500
E0538 GSF050.2H/37-ENS 23800
E0540 GSF050.2J/37.ENS 26200
E0543 GSF050.2H/47-ENS 30800
81Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Hea
t Exc
hang
ers
Med
ium
Tem
p Te
chni
cal D
ata
Real
cold
Stoc
k N
o.N
ew M
odel
CP 13
4A@
6K
TD
404A
Air
Flow
(m
³/s)
Air
Thro
w
(m)
Fan
Stoc
k N
umbe
r
No
Fan
Fan
D
iaFa
n po
wer
(A
mp
ea)
D/F
Elem
ent
Num
ber
Def
rost
(k
W)
D/F
Tray
N
umbe
rD
imen
sion
sCo
nnec
tions
Dra
in
(BSP
)W
eigh
t (K
g)L
WH
Inle
tO
utle
t
W55
00TM
140
4165
4082
0.8
——
140
00.
78n/
a—
n/a
1224
845
355
12.7
22.3
2038
W55
02TM
270
7143
7000
1.6—
—2
400
0.78
n/a
—n/
a17
0585
036
012
.722
.320
59
W55
04TM
3100
1020
410
000
2.4
——
340
00.
78n/
a—
n/a
2205
850
360
12.7
28.1
2085
W55
08TM
3140
1428
614
000
3.3
——
440
00.
78n/
a—
n/a
2705
850
360
12.7
28.1
2012
1
W50
00N
M11
414
0013
720.
739.
0R0
930
130
00.
68n/
a—
n/a
770
400
395
12.7
15.9
2017
W50
02N
M11
716
9016
560.
688.
5R0
930
130
00.
68n/
a—
n/a
770
400
395
12.7
15.9
2018
W50
04N
M12
120
9020
480.
648.
0R0
930
130
00.
68n/
a—
n/a
770
400
395
12.7
15.9
2019
W50
06N
M12
423
7023
230.
738.
0R0
930
130
00.
68n/
a—
n/a
975
400
395
12.7
15.9
2021
W50
08N
M12
727
1026
560.
77.
5R0
930
130
00.
68n/
a—
n/a
975
400
395
12.7
15.9
2023
W50
10N
M23
232
0031
361.4
59.
0R0
930
230
00.
68n/
a—
n/a
1270
400
395
12.7
15.9
2025
W50
12N
M24
039
5038
711.3
68.
5R0
930
230
00.
68n/
a—
n/a
1270
400
395
12.7
15.9
2027
W50
14N
M24
545
2044
301.2
88.
0R0
930
230
00.
68n/
a—
n/a
1270
400
395
12.7
22.3
2029
W50
16N
M25
454
5053
412.
058.
0R0
930
330
00.
68n/
a—
n/a
1770
400
395
12.7
22.3
2044
W50
18N
M46
464
0062
722.
919.
0R0
930
430
00.
68n/
a—
n/a
2270
400
395
12.7
22.3
2050
W50
20N
M37
474
0072
521.9
37.
5R0
930
330
00.
68n/
a—
n/a
1770
400
395
12.7
22.3
2047
W50
22N
M47
978
9577
372.
738.
0R0
930
430
00.
68n/
a—
n/a
2270
400
395
15.9
28.1
2058
W50
24SM
271
7102
6960
1.76
17.0
R093
52
350
0.58
n/a
—n/
a14
8348
251
012
.722
.320
48
W50
26SM
386
8599
8427
2.7
18.0
R093
53
350
0.58
n/a
—n/
a22
3348
251
015
.929
2071
W50
28SM
3105
1065
310
440
2.64
17.0
R093
53
350
0.58
n/a
—n/
a22
3348
251
015
.935
2075
W50
30SM
3125
1243
412
185
2.58
16.0
R093
53
350
0.58
n/a
—n/
a22
3348
251
015
.935
2079
W50
32SM
4140
1420
413
920
3.52
17.0
R093
54
350
0.58
n/a
—n/
a27
3148
251
015
.935
2092
W50
34SM
4165
1657
416
243
3.44
16.0
R093
54
350
0.58
n/a
—n/
a27
3148
251
015
.935
2098
W50
36SM
5210
2117
920
340
4.28
19.0
R093
55
350
0.58
n/a
—n/
a32
2348
251
015
.935
4012
1
HEAT EXCHANGERSREALCOLD EVAPORATOR DATA
82Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Hea
t Exc
hang
ers
HEAT EXCHANGERSREALCOLD EVAPORATOR DATA
Med
ium
Tem
p Te
chni
cal D
ata
Real
cold
Stoc
k N
o.N
ew M
odel
CP 13
4A@
6K
TD
404A
Air
Flow
(m
³/s)
Air
Thro
w
(m)
Fan
Stoc
k N
umbe
r
No
Fan
Fan
D
iaFa
n po
wer
(A
mp
ea)
D/F
Elem
ent
Num
ber
Def
rost
(k
W)
D/F
Tray
N
umbe
rD
imen
sion
sCo
nnec
tions
Dra
in
(BSP
)W
eigh
t (K
g)L
WH
Inle
tO
utle
t
W52
00SM
271P
7102
6960
1.76
18.0
R093
52
350
0.58
W72
401.5
n/a
1483
482
510
12.7
22.3
2048
W52
02SM
386P
8599
8427
2.7
20.0
R093
53
350
0.58
W72
422.
4n/
a22
3348
251
015
.929
2071
W52
04SM
3105
P10
653
1044
02.
6419
.0R0
935
335
00.
58W
7242
2.4
n/a
2233
482
510
15.9
3520
75
W52
06SM
3125
P12
434
1218
52.
5818
.0R0
935
335
00.
58W
7242
2.4
n/a
2233
482
510
15.9
3520
79
W52
08SM
4140
P14
204
1392
03.
5217
.0R0
935
435
00.
58W
7244
3.0
n/a
2731
482
510
15.9
3540
92
W52
10SM
4165
P16
574
1624
33.
4416
.0R0
935
435
00.
58W
7244
3.0
n/a
2731
482
510
15.9
3540
98
W52
12SM
5210
P21
179
—4.
2819
.0R0
935
535
00.
58W
7246
3.0
n/a
3223
482
510
15.9
3540
121
W52
30RM
2140
1400
013
333
4.1
24.0
R095
02
500
1.85
—4.
5n/
a22
1067
080
516
2940
132
W52
32RM
3185
1840
017
524
5.0
24.0
R095
03
500
1.85
—4.
5n/
a22
4068
510
7516
3540
173
W52
34RM
3210
2060
019
619
5.4
24.0
R095
03
500
1.85
—4.
5n/
a27
4068
510
7516
3540
196
W52
36RM
3230
2310
022
000
5.1
24.0
R095
03
500
1.85
—5.
4n/
a27
4068
510
7516
3540
198
W52
38RM
3250
2520
024
000
6.6
24.0
R095
04
500
1.85
—4.
5n/
a27
4068
510
7516
3540
242
W52
40RM
4280
2810
026
762
6.4
24.0
R095
04
500
1.85
—5.
4n/
a27
4068
510
7516
3540
242
W52
42VM
2310
3100
029
524
8.3
25.0
R096
32
630
1.8—
5.4
n/a
2240
775
1305
1635
4028
0
W52
44VM
2340
3440
032
762
7.0
26.0
R096
32
630
1.8—
4.8
n/a
2240
775
1305
1641
4034
0
W52
46VM
3400
4000
038
095
10.4
26.0
R096
33
630
1.8—
6.0
n/a
3240
775
1305
1641
4042
0
W52
48VM
3450
4510
042
952
10.2
26.0
R096
33
630
1.8—
7.2
n/a
3240
775
1305
16x2
35x2
4042
0
W52
50VM
3480
4830
046
000
10.4
26.0
R096
33
630
1.8—
7.2
n/a
3600
775
1305
16x2
35x2
4043
0
W52
52VM
4520
5200
049
524
13.0
28.0
R096
34
630
1.8—
8.0
n/a
3600
775
1305
16x2
35x2
4043
0
W52
54VM
4560
5600
053
333
13.6
28.0
R096
34
630
1.8—
8.8
n/a
3890
775
1305
16x2
35x2
4051
0
83Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Hea
t Exc
hang
ers
HEAT EXCHANGERSREALCOLD EVAPORATOR DATA
Low
Tem
p Te
chni
cal D
ata
Real
cold
Stoc
k N
o.
New
Mod
elCP
R 40
4a@
6K
TD
R22
Air
Flow
(m
³/s)
Air
Thro
w
(m)
Fan
Stoc
k N
o
No
Fan
Fan
Dia
Fan
pow
er
(Am
p ea
)
Stoc
k N
oD
efr.
(kW
)D
/F Tr
ay
Num
ber
Wat
tsD
imen
sion
sCo
nnec
tions
Dra
in
(BSP
)W
eigh
t (K
g)L
WH
Inle
tO
utle
t
W50
50N
L112
1210
1184
0.73
9.0
R093
01
300
0.68
n/a
1.4W
7200
1400
770
400
395
12.7
15.9
2017
W50
52N
L115
1455
1426
0.68
8.5
R093
01
300
0.68
n/a
1.4W
7200
1400
770
400
395
12.7
15.9
2018
W50
54N
L118
1800
1763
0.64
8.0
R093
01
300
0.68
n/a
1.4W
7200
1400
770
400
395
12.7
15.9
2019
W50
56N
L120
2040
1998
0.73
8.0
R093
01
300
0.68
n/a
1.4W
7202
1800
975
400
395
12.7
15.9
2021
W50
58N
L123
2330
2288
0.7
7.5
R093
01
300
0.68
n/a
1.4W
7202
1800
975
400
395
12.7
15.9
2023
W50
60N
L228
2760
2706
1.45
9.0
R093
02
300
0.68
n/a
2.4
W72
0424
0012
7040
039
512
.715
.920
29
W50
62N
L234
3400
3330
1.36
8.5
R093
02
300
0.68
n/a
2.4
W72
0424
0012
7040
039
512
.715
.920
31
W50
64N
L239
3890
3815
1.28
8.0
R093
02
300
0.68
n/a
2.4
W72
0424
0012
7040
039
512
.722
.320
33
W50
66N
L347
4695
4601
2.05
8.0
R093
03
300
0.68
n/a
3.6
W72
0836
0017
7040
039
512
.722
.320
44
W50
68N
L455
5520
5413
2.91
9.0
R093
04
300
0.68
n/a
4.8
W72
1048
0022
7040
039
512
.722
.320
50
W50
70N
L464
6375
6375
1.93
7.5
R093
03
300
0.68
n/a
3.6
W72
0836
0017
7040
039
512
.722
.320
47
W50
72N
L468
6800
6668
2.73
8.0
R093
04
300
0.68
n/a
4.8
W72
1048
0022
7040
039
515
.928
.120
58
W50
74SL
261
6119
5997
1.76
17.0
R093
52
350
0.58
W72
403.
5W
7206
2000
1483
482
510
12.7
22.3
2048
W50
76SL
374
7409
7261
2.7
18.0
R093
53
350
0.58
W72
426.
0W
7210
4800
2233
482
510
15.9
2920
71
W50
78SL
392
9179
8995
2.64
17.0
R093
53
350
0.58
W72
427.
2W
7210
4800
2233
482
510
15.9
3520
75
W50
80SL
3110
1071
310
499
2.58
16.0
R093
53
350
0.58
W72
427.
2W
7210
4800
2233
482
510
15.9
3520
79
W50
82SL
4120
1223
911
994
3.52
17.0
R093
54
350
0.58
W72
447.
7W
7212
3200
2723
482
510
15.9
3540
92
W50
84SL
4145
1428
213
996
3.44
16.0
R093
54
350
0.58
W72
447.
7W
7212
3200
2723
482
510
15.9
3540
98
W50
86SM
521
0P17
836
1747
94.
2819
.0R0
935
535
00.
58W
7246
9.0
W72
2418
0032
2348
251
015
.935
4012
1
* O
ptio
nal 2
spe
ed Z
iehl
pla
te a
xial
or E
C fa
ns a
vaila
ble
for R
and
V e
vaps
ser
ies
on re
ques
t.
84Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Hea
t Exc
hang
ers
HEAT EXCHANGERSREALCOLD EVAPORATOR DATA
Low
Tem
p Te
chni
cal D
ata
Real
cold
Stoc
k N
o.
New
Mod
elCP
R 40
4a@
6K
TD
R22
Air
Flow
(m
³/s)
Air
Thro
w
(m)
Fan
Stoc
k N
o
No
Fan
Fan
Dia
Fan
pow
er
(Am
p ea
)
Stoc
k N
oD
efr.
(kW
)D
/F Tr
ay
Num
ber
Wat
tsD
imen
sion
sCo
nnec
tions
Dra
in
(BSP
)W
eigh
t (K
g)L
WH
Inle
tO
utle
t
W52
60RL
3160
1620
015
600
4.6
24.0
R050
03
500
1.85
W72
409.
0W
7222
3600
2740
670
805
1635
4017
3
W52
62RL
3185
1850
017
800
4.8
24.0
R050
03
500
1.85
W72
4210
.8W
7224
3600
3240
670
805
1635
4019
6
W52
64RL
3200
1970
018
950
4.8
24.0
R050
03
500
1.85
W72
4210
.8W
7222
3600
2740
685
1075
1635
4019
8
W52
66RL
4220
2170
020
865
6.8
25.0
R050
04
500
1.85
W72
4412
.6W
7224
3600
3240
685
1075
1635
4019
8
W52
68RL
4250
2470
023
750
6.4
25.0
R050
04
500
1.85
W72
4414
.4W
7224
3600
3240
685
1075
1635
4024
2
W52
70VL
2280
2800
026
900
7.0
25.0
R063
02
630
1.8W
7246
10.8
W72
2036
0022
4077
513
0516
3540
242
W52
72VL
2300
3000
028
850
7.1
25.0
R063
02
630
1.8W
7244
13.5
W72
2236
0027
4077
513
0516
4140
290
W52
74VL
3350
3500
033
500
10.4
26.0
R063
03
630
1.8W
7246
14.4
W72
2436
0032
4077
513
0516
4140
345
W52
76VL
3400
4000
038
500
10.2
26.0
R063
03
630
1.8W
7246
16.2
W72
2436
0032
4077
513
0516
x235
x240
345
W52
78VL
4450
4500
043
269
12.0
27.0
R063
04
630
1.8W
7248
18.0
W72
2664
0036
0077
513
0516
x235
x240
430
W52
80VL
4500
5000
048
077
13.2
27.0
R063
04
630
1.8W
7250
19.8
W72
8864
0038
9077
513
0516
x235
x240
430
* O
ptio
nal 2
spe
ed Z
iehl
pla
te a
xial
or E
C fa
ns a
vaila
ble
for R
and
V e
vaps
ser
ies
on re
ques
t.
85Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Hea
t Exc
hang
ers
Air Cooled Condensers Feature:
Steelfort is well known for its quality and innovation of these Air Cooled Condensers.
Specialising in the design and manufacture of Castle finned tube heat exchangers, Steelfort uses unique computer software developed in collaboration with Massey University’s School of Engineering and Advanced Technology.
Casing: The casing is made from the highest quality aluminium construction, utilising rust free stainless steel fasteners throughout.
Heat Exchange Element (coil): Die formed plate type aluminium fins mechanically bonded to high efficiency inner grooved (rifled) copper tube.
Optional Epoxy Coated Aluminium Fins: For added protection in salt laden or polluted atmospheres.
Fans: Standard 630 diameter basket grill. Optional Ziehl or EC fans on request.
Custom built: Custom built units outside the standard range available on request.
HEAT EXCHANGERSAIR COOLED CONDENSERS
86Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Hea
t Exc
hang
ers
Evaporator Mounting Kits - NylonRealcoldStock No.
Model Contains Recommended max. safe working load
Price$ Excl. GST
Bluemay Kits
J3210Bluemay Chiller 4 Bolt KitBolt - 10 mm diameter and 150 mm length
4 x J3040 nut4 x J3060 washer faced nut4 x J3130 washer4 x J3180 bolt
320 Kg
J3212Bluemay Freezer Kit 4 Bolt KitBolt - 10 mm diameter and 250 mm length
4 x J3040 nut4 x J3060 washer faced nut4 x J3130 washer4 x J3182 bolt
320 Kg
J3211Bluemay Chiller 6 Bolt KitBolt - 10 mm diameter and 150 mm length
6 x J3040 nut6 x J3060 washer faced nut6 x J3130 washer6 x J3180 bolt
480 Kg
J3213Bluemay Freezer 6 Bolt KitBolt - 10 mm diameter and 250 mm length
6 x J3040 nut6 x J3060 washer faced nut6 x J3130 washer6 x J3182 bolt
480 Kg
• The use of steel or brass nuts with Thermoplastic rod is not recommended.• See technical data for temperature limitations. Not recommended for below -30ºC.• Care should be taken not to over-tighten nuts when used with Thermoplastic threaded rod.
Nuts should be tightened by hand and given half a turn with a spanner.
Features & Benefits
Nylon threaded rod and Buffalo bolts, together with associated products, have been at the heart of Bluemay’s manufacturing operation since 1973. This very special range is widely held in high regard by customers who have come to rely on its exceptional qualities and high standard of production.
Threaded Rod, Thermoplastic Nuts and Washers are available in Nylon 66, one of the strongest grades of engineering plastic. This remarkable material has many features, including a melting point of 260˚C, a tensile strength at 23˚C of 62-83 N/mm², and a 1-3% deformation under load 14N/mm² after 24 hours, at 50˚C.
The products in the Bluemay range are:
• Efficient thermal and electrical insulators• Non-corrosive• Lightweight and easy to handle• Hygenic
HEAT EXCHANGERSEVAPORATOR MOUNTINGS
87Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Hea
t Exc
hang
ers
Thermoplastic - NylonRealcoldStock No.
Description Recommended max. safe working load
Price$ Excl. GST
Threaded Rod
J3010 Nylon Threaded Rod M10 x 1.0 metre 80 Kg
J3012 Nylon Threaded Rod M12 x 1.0 metre 120 Kg
Buffalo Panel Bolts
J3180 Nylon Panel Bolts M10 x 150 mm 80 Kg
J3182 Nylon Panel Bolts M10 x 250 mm 80 Kg
J3190 Nylon Panel Bolts M12 x 150 mm 120 Kg
J3192 Nylon Panel Bolts M12 x 250 mm 120 Kg
Full Hexagonal Nuts
J3040 Nylon Full Hex Nuts M10 80 Kg
J3042 Nylon Full Hex Nuts M12 120 Kg
Washer Faced Nuts
J3060 Nylon Washer Faced Nut M10
J3062 Nylon Washer Faced Nut M12
Dome Nuts
J3080 Nylon Dome Nut M10 80 Kg
J3082 Nylon Dome Nut M12 120 Kg
Buffalo T-Nut
J3160 Nylon T-Nut M10 80 Kg
J3162 Nylon T-Nut M12 120 Kg
Washer - Standard
J3110 Nylon M10 Washer 10.5 mm ID x 21.0 mm OD x 2.0 mm Thick
J3112 Nylon M12 Washer 13.0 mm ID x 24.0 mm OD x 2.5 mm Thick
Washer - Load Bearing
J3130 Nylon M10 Washer 10.5 mm ID x 45 mm OD x 4.5 mm Thick
J3131 Nylon M10 Washer 10.5 mm ID x 75 mm OD x 4.5 mm Thick
J3142 Nylon M12 Washer 13.0 mm ID x 50 mm OD x 4.5 mm Thick
J3143 Nylon M12 Washer 14.0 mm ID x 75 mm OD x 4.5 mm Thick
Mushroom Head Bolts - (coolroom bolts)
J1285 Mushroom Head Bolt M16 x 250 mm
J1287 Mushroom Head Bolt M16 x 300 mm
J1290 Nylon Nut M16
J1292 Nylon Washer M16
Threaded Rod
Mushroom Head Bolt
Buffalo T-Nut
Buffalo Panel Bolt
Dome Nut
Washer Faced Nut
HEAT EXCHANGERSEVAPORATOR MOUNTINGS
88Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Ice
Mac
hine
s
Ice MachinesSIZING GUIDE
Ice Machines
Realcold can source and supply a range of Ice making machines to suit your needs. From cube to tube, to crushed ice and flake ice.
Talk to Realcold and we will work with you to find the best solution.
To follow is an approximate sizing guide to assist in your planning.
Soft DrinksIce Glass Size
85 ml 200 ml
90 ml 240 ml
105 ml 300 ml
130 ml 350 ml
Ice Glass Size
155 ml 420 ml
175 ml 470 ml
180 ml 500 ml
Add 50% if using a cold plate.
Bars / Cocktail LoungeIce
1.4 kg Per Customer
Salad BarsIce
53 kg Per Sq Metre 100 mm Deep
RestaurantsIce
1.4 kg Per Customer
Hotels / Motel Room ServiceIce
2.3 kg Per Customer
Water ContainersIce
0.48 kg Per Litre
CafeteriasIce
1.4 kg Per Customer
Hotels / Motel Food ServiceIce
0.7 kg Per Customer
Hotels / Motel Banquet ServiceIce
0.5 kg Per Customer
Health CareIce
2.7 kg Per Bed
0.9 kg Per Employee
HospitalsIce
2.3 kg Per Bed
89Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Ice
Mac
hine
sIce MachinesKEY BRANDS
Hoshizaki Ice Machines
Save Water Consumption: Microcomputer automatically controls volume of water during the defrost cycle. Water inlet valve saves incoming water.
Bin Control Switch: When the bin is full of ice, bin control switch detects and automati-cally shuts down the ice making process. Reliable mechanical switch is fitted in cubers for consistent operation.
Smart Computer Board: No need for manual adjustments. Dependable Hoshizaki computer board controls ice supply in the most efficient and productive way in any condition.
Sanitary Construction: One piece insulation, snug fit top cover, magnetic door gasket and door side protector prevents incoming dust, water and insects.
Long Life Main Parts: Main parts such as compressor, fan-motor, pump-motor are uniquely designed to ensure ice cubers ‘ long life.
Easily Cleaned Air-Filter: Air filter can be cleaned easily upon removing the front cover. Clean air-filter contributes to the maximum ice making production.
KOLD-DRAFT® Ice Machines
KOLD-DRAFT®, a leader in the manufacture of high quality commercial ice machines since 1954, has been the premier brand for discerning foodservice, bar, and hotel operations who demand the highest quality. KOLD-DRAFT equipment makes pure ice cubes in three sizes and crushed ice in two sizes as well as crushed ice to fill any need for hotels, restau-rants, bars, hospitals, and other institutions.
KOLD-DRAFT features a wide range of commercial ice machines and bins capable of pro-ducing from 135 to 1,000 kg of pure ice per day. Each ice system can be configured to produce full cubes or half cubes
Plus, with over half a century of time-proven design, KOLD-DRAFT ice machines are com-patible with new and old KOLD-DRAFT commercial ice machines, bins, crushers and dis-pensers. Many of the parts are interchangeable between models as well, so on the rare occasion an commercial ice machine does need to be serviced, it is much easier to fix.
KOLD-DRAFT uses the horizontal ice making system, which means:
• The water control system, water plate assembly, and exclusive “upside-down” horizontal evaporator combine to make a time-proven system that ensures better ice making every time
• With the solidity and purity of KOLD-DRAFT ice, making it the slowest-melting ice so it won’t distort the taste of any drink and last longer.
Maxx Ice Machines
The clear choice for quality ice. Maxx Ice represents the most efficient and cost effective method of meeting your ice needs. Designed to incorporate maximum energy and water conservation and built to produce ice simply and efficiently, Maxx Ice is the clear choice for maximum value.
Maxx Ice machines are designed and manufactured with simplicity and efficiency in mind. Maxx didn’t design these machines with a lot of bells and whistles. Customers simply want an ice machine that is simple to operate, one that works, and one that saves them money. Water and electricity in, clear and clean ice out, at a value. That’s what Maxx Ice does.
With a vast product offering that includes daily ice production of 23kg up to 500kg.
Maxx Ice machines feature stainless steel construction, standard automatic overfill preven-tion, and are suitable for built-in or free standing applications.
90Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Ice
Mac
hine
s
Ice MachinesKEY BRANDS & FLAKE ICE
Vogt Ice Machines
Vogt revolutionized the commercial ice-making industry in 1937 when it built the world’s first automatic sized ice machine, the Tube-Ice Machine. Prior to this, ice was made in block form. Vogt engineers designed the unique Tube-Ice Machine specifically to freeze ice au-tomatically in vertical tubes, momentarily thaw ice loose from the tubes and then cut it into short cylinders with a hole in the center. The hole is formed during the formation of the ice as a result of the falling film of water freezing inside the vertical tubes.
Today, Vogt ice machines offer a wide variety of ice to suit any of your ice needs including fragmented, cracked, crushed, flake, and of course the original Tube Ice in an assortment of sizes. We also manufacture the Turbo Ice Rake, manual and automatic block presses as well as falling film chillers
Applications
• Fish/Seafood Icing• Produce Cooling• Meat/Poultry• Packaged Ice• Thermal Energy Storage• Turbine Inlet Cooling• Concrete Cooling• Baking Industry Applications• Chemical and Dye Processing
Flake Ice Machines
What Is Flake Ice? Flake-ice is small ice in flat pieces. It is used in cooling seafood, in meat processing and in a whole range of industrial processes. Flake-ice is dry and sub-cooled (-6°C approx). With a moderate production cost compared to most of the other kinds of ice, flake-ice is used in large quanti-ties in many industrial and food processes.
Substantial Cooling Power: Slightly sub-cooled, flake-ice is also a dry ice. The “ ice only “ feature of its manufacture means that the latent heat, the principal source of the cooling energy, is 100 % available.
Accurate Cooling: As flake-ice is dry, its cooling input can be accurately calculated and its effects on the temperature of the mixture are quickly apparent.
Easy Handling And Storage: Flake-ice is free flowing, its flakes do not stick together and form blocks. They are light and cushion the product to reduce the risk of crushing or deterioration.
The Realcold Complete Unit consists of:
• Low Temp Condensing Unit, fully connected to the Ice Generator • Built on its own steel frame• Fully wired package to its own control panel• Salt Dose Pump Kit (if required)• Unit evacuated and charged with dry nitrogen
Site Requirements:
• Refrigerant Charge• 3 Phase electrical supply• Fresh water supply• Full commissioning
91Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Air
Con
ditio
ning
AIR CONDITIONINGMHI INTRODUCTION
MHI Introduction
Mitsubishi Heavy Industries is a major supplier of commercial and residential air conditioning products in New Zealand and the South Pacific. MHIAA is a wholly owned subsidiary of Mitsubishi Heavy Industries, Ltd, a large and diverse organisation that has many divisions such as ship building, power plant, general machinery, aerospace and of course air conditioning.
MHI enjoys a reputation for supplying a comprehensive range of technically advanced energy efficient air conditioning systems.
MHI’s Mission Statement
• We strongly believe that the customer comes first and that we are obligated to be an innovative partner to society.• We base our activities on honesty, harmony, and a clear distinction between public and private life.• We shall strive for innovative management and technological development from an international perspective.
92Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Air
Con
ditio
ning
AIR CONDITIONINGSRK ZJ SERIES HI-WALL SPLIT SYSTEMS
Reverse Cycle Inverter Hi-Wall - R410ARealcoldStock No. Mitsubishi
Model No.
Refrigerant Cap kW T1 Nominal~Range
Noise dBAIND/OUT
Weight (Kg)IND/OUT
ElectricSupply
System Nett Price
$ Excl. GST
AC3060 SRK20ZJ-Set R410A2.0 (1.0~2.7) 33~27~21 9.5
230/1/502.7 (1.2~3.9) 59 32
AC3061 SRK25ZJ-Set R410A2.5 (1.0~2.9) 34~28~21 9.5
230/1/503.2 (1.2~4.2) 58 38
AC3062 SRK35ZJ-Set R410A3.3 (1.0~3.8) 45~32~22 9.5
230/1/504.0 (1.3~4.8) 60 38
AC3063 SRK50ZJ-Set R410A5.0 (1.6~5.5) 46~37~26 9.5
230/1/505.8 (1.6~6.6) 61 42
Specifications - Hi-Wall Reverse Cycle - SRK ZJSRK ZJ Hi-Wall Series SRK20ZJ-SI
SRC20ZJ-SISRK25ZJ-SI SRC25ZJ-SI
SRK35ZJ-SI SRC35ZJ-SI
SRK50ZJ-SI SRC50ZJ-SI
Power Supply Outdoor Unit 1phase 230V 50Hz
CapacityCooling T1
kW2.0 (1.0~2.7) 2.5 (1.0~2.9) 3.3 (1.0~3.8) 5.0 (1.6~5.5)
Heating H1 2.7 (1.2~3.9) 3.2 (1.2~4.2) 4.0 (1.3~4.8) 5.8 (1.6~6.6)
InputCooling T1
kW0.44 0.58 0.87 1.55
Heating H1 0.62 0.7 0.96 1.59
Energy Label 2011Cooling
Stars4.0 3.5 3 1.5
Heating 3.5 4.5 3.5 2.5EER Cooling T1 4.55 4.35 3.79 3.23COP Heating T1 4.35 4.57 4.19 3.65COP Heating H2 2.64 2.97 2.94 2.57
CurrentCooling T1
Amp2.5 3.0 4.3 7.1
Heating H1 3.2 3.5 4.6 7.3Recommended Circuit Breaker AmpSound Pressure Level (JIS C9612)
Cool InddB
33~27~21 34~28~21 45~32~22 46~37~26Heat Ind 36~31~24 39~31~24 42~37~25 45~37~31
Sound Pressure Level (JIS C9612) Outdoor dBA 59 58 60 61
Airflow Indoor L/S 130~93~80 131~100~83 190~106~83 188~130~88External Dimensions (H x W x D)
Indoormm
294 x 798 x 229Outdoor 540 x 780(+62) x 290 595 x 780(+62) x 290 640 x 800(+71) x 290
Nett WeightIndoor
Kg9.5
Outdoor 32 38 42
Refrigerant PipingLiquid Line
mm (in)6.35 (1/4”)
Gas Line 9.52 (3/8") 12.7 (1/2")Conn Method Flare
Refrigerant R410A QuantityKg 0.75 1.15 1.35m 15
Max. Piping Length Overall/Height m 15 / 10 25 / 15
Features & Benefits
• New SRK**ZJ-S1 models
• All SRK Series exceeds MEPS IV• New SRK20ZJ-S1, 2.0kW model • Silicon Coated PCB
• Allergen Filter• Self clean operation• 5 Year Warranty on Parts and Labour• Self Diagnostics
93Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Air
Con
ditio
ning
Reverse Cycle Inverter Hi-Wall - R410ARealcoldStock No.
MitsubishiModel No.
Refrigerant Cap kW T1 Nominal~Range
Noise dBAIND/OUT
Weight (Kg)IND/OUT
ElectricSupply
System Nett Price
$ Excl. GST
AC3064 SRK63ZK-Set R410A6.3 (2.15~7.1) 47~43~37~26 15
230/1/507.1 (1.7~9.5) 62 57
AC3065 SRK71ZK-Set R410A7.1 (2.15~8.0) 49~45~39~26 15
230/1/508.0 (1.6~10) 66 57
AC3066 SRK80ZL-Set R410A8.0 (2.15~9.0) 51~47~41~26 15
230/1/509.0 (1.7~10.5) 67 65
AC3067 SRK92ZL-Set R410A9.2 (2.4~10.0) 51~47~41~26 15
230/1/5010 (2.2~11.2) 67 91
Specifications - Hi-Wall Reverse Cycle - SRK ZK/ZLSRK ZK/ZL Series Hi-Wall Series SRK63ZK-S
SRC63ZK-SSRK71ZK-SSRC71ZK-S
SRK80ZL-SSRC80ZK-S
SRK92ZL-S SRC92ZL-S
Power Supply Outdoor Unit 1 phase 230V 50Hz
CapacityCooling T1
kW6.3 (2.15~7.1) 7.1 (2.15~8.0) 8.0 (2.15~9.0) 9.2 (2.4~10.0)
Heating T1 7.1 (1.7~9.5) 8.0 (1.6~10) 9.0 (1.7~10.5) 10 (2.2~11.2)
InputCooling T1
kW1.76 2.16 2.35 2.54
Heating T1 1.79 2.14 2.57 2.84
Energy Label MEPS 4Cooling
Stars2 1.5 2 2.5
Heating 3 2.5 2 2EER Cooling T1 3.58 3.29 3.4 3.62COP Heating T1 3.97 3.74 3.5 3.52COP Heating H1 2.77 2.77 2.67 2.78
CurrentCooling T1
Amp8.3 10.1 11 11.9
Heating H1 8.5 10.1 12 13.3Recommended Circuit Breaker Amp 20Sound Pressure Level (JIS C9612)
Cool InddB
47~43~37~26 49~45~39~26 51~47~41~26 51~47~41~26Heat Ind 44~41~36~33 46~43~39~35 48~45~40~37 48~45~40~37
Sound Pressure Level (JIS C9612)
Outdoor dBA 62 66 67 67
Airflow Indoor L/S 310 325 350 350External Dimensions (H x W x D)
Indoormm
318 x 1098 x 248Outdoor 750 x 880 (+88) x 340 970 x 845 x 370 1300 x 970 x 370
Nett WeightIndoor
Kg15
Outdoor 57 65 91
Refrigerant PipingLiquid Line
mm (in)6.35 (1/4")
Gas Line 15.88 (5/8")Conn Method Flare
Refrigerant R410A QuantityKg 1.8 2.2 3.15m Pre-charged for 15mtrs of field piping
Max. Piping Length Overall/Height m 30 / 20
AIR CONDITIONINGSRK ZK/ZL SERIES HI-WALL SPLIT SYSTEMS
Features & Benefits
• Hi Power• Alergen Clear & Photocatalytic filters• Long Reach Air Flow, Three Sensors• Self Clean Operation
• Silicon Coated PCB• Superior Corrosion Resistance• NEW SRK92ZL-S, 92 kW model• 5 Year Warranty on Parts and Labour
94Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Air
Con
ditio
ning
AIR CONDITIONINGHIGH EER/COP SERIES HI-WALL SPLIT SYSTEMS
Reverse Cycle Inverter Hi-Wall - R410A High EER/COPRealcoldStock No.
MitsubishiModel No.
Refrigerant Cap kW T1 Nominal~Range
Noise dBAIND/OUT
Weight (Kg)IND/OUT
ElectricSupply
Price $ Excl GST
AC3101 SRK20ZJX-Set R410A2.0 (0.9~3.1) 39~30~21 15
230/1/502.5 (0.9~4.3) 60 38
AC3102 SRK25ZJX-Set R410A2.55 (0.9~3.2) 41~31~22 15
230/1/503.13 (0.9~4.7) 60 38
AC3103 SRK35ZJX-Set R410A3.5 (0.9~4.1) 43~33~22 15
230/1/504.3 (0.9~5.1) 63 38
AC3104 SRK50ZJX-Set R410A5.0 (1.1~5.8) 47~40~27 15
230/1/506.0 (0.6~7.7) 63 45
AC3105 SRK60ZJX-Set R410A6.0 (1.1~6.8) 51~41~29 15
230/1/506.8 (0.6~8.2) 64 45
Specifications - Hi-Wall Reverse Cycle - SRK - ZJXSRK-ZJX Hi-Wall Series SRK20ZJX-S
SRC20ZJX-SSRK25ZJX-SSRC25ZJX-S
SRK35ZJX-SSRC35ZJX-S
SRK50ZJX-SISRC50ZJX-SI
SRK60ZJX-SISRC60ZJX-S
Power Supply Outdoor Unit 1 phase 230V 50Hz
CapacityCooling T1
kW2.0 (09~3.1) 2.55 (0.9~3.2) 3.5 (0.9~4.1) 5.0 (1.1~5.8) 6.0 (1.1~6.8)
Heating T1 2.5 (0.9~4.3) 3.13 (0.9~4.7) 4.3 (0.9~5.1) 6.0 (0.6~7.7) 6.8 (0.6~8.2)
InputCooling T1
kW0.35 0.49 0.845 1.3 1.86
Heating T1 0.45 0.595 0.96 1.36 1.67
Energy Label 2011Cooling
Stars6 5 3 3 1.5
Heating 5.5 5.5 3.5 4 3.5EER Cooling T1 5.71 5.2 4.14 3.85 3.23COP Heating T1 5.56 5.26 4.48 4.41 4.07COP Heating H2 3.58 3.46 3.22 3.21 2.71
CurrentCooling T1
Amp1.9 2.5 4.0 6.0 8.5
Heating H1 2.4 3.1 4.6 6.2 7.7Recommended Circuit Breaker Amp 16Sound Pressure Level (JIS C9612)
Cool InddB
39~30~21 41~31~22 43~33~22 47~40~27 51~41~29Heat Ind 38~33~25 41~34~27 42~35~27 48~40~33 48~41~34
Sound Pressure Level (JIS C9612)
Outdoor dBA 60 60 63 63 64
Airflow Indoor L/S 191~133~83 208~150~83 225~158~83 225~183~133 242~208~142External Dimensions (H x W x D)
Indoormm
309 x 890 x 220Outdoor 595 x 780 (+62) x 290 640 x 800 (+71) x 290
Nett WeightIndoor
Kg15
Outdoor 38 45
Refrigerant PipingLiquid Line
mm (in)6.35 (1/4”)
Gas Line 9.52 (3/8”) 12.7 (1/2”)Conn Method Flare
Refrigerant R410A QuantityKg 1.2 1.5m Pre-charged for 15m of field piping
Max. Piping Length Overall/Height m 15 / 10 30 / 20
Features & Benefits
• High COP / EER• Alergen Clear & Photocatalytic filters
• Self Clean Operation• Long Reach Air Flow SRK50/60ZJX
• Silicon Coated PCB• Superior Corrosion Resistance• 5 Year Warranty on Parts and Labour
95Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Air
Con
ditio
ning
AIR CONDITIONINGSRF FLOOR MOUNTED SPLIT SYSTEMS
Reverse Cycle Inverter Floor Console - R410ARealcoldStock No.
MitsubishiModel No.
Refrigerant Cap kW T1 Nominal~Range
Noise dBAIND/OUT
Weight (Kg)IND/OUT
ElectricSupply
Price$ Excl. GST
AC3201 SRF25ZJX-Set R410A2.5 (0.9~3.2) 38~31~26 18
230/1/503.4 (0.9~4.7) 60 38
AC3202 SRF35ZJX-Set R410A3.5 (0.9~4.1) 41~34~28 19
230/1/504.5 (0.9~5.1) 63 38
AC3203 SRF50ZJX-Set R410A5.0 (0.7~5.5) 46~42~32 19
230/1/506.0 (0.7~7.0) 63 45
Specifications - Reverse Cycle Floor Console - SRF - ZJXSRF Floor Mounted Series SRF25ZJX-S
SRC25ZJX-SSRF35ZJX-SSRC35ZJX-S
SRF50ZJX-SISRC50ZJX-S
Power Supply Outdoor Unit 1 phase 230V 50Hz
CapacityCooling T1
kW2.5 (0.9~3.2) 3.5 (0.9~4.1) 5.0 (0.7~5.5)
Heating T1 3.4 (0.9~4.7) 4.5 (0.9~5.1) 6.0 (0.7~7.0)
InputCooling T1
kW0.521 0.89 1.39
Heating T1 0.723 1.124 1.54
Energy Label 2011Cooling
Stars4 2.5 2.5
Heating 4 3 3
EER Cooling T1 4.8 3.93 3.6
COP Heating T1 4.7 4 3.9
COP Heating H2 3.17 2.96 3.03
CurrentCooling T1
Amp2.5 3.9 6.1
Heating H1 3.4 4.9 6.8
Recommended Circuit Breaker Amp 16
Sound Pressure Level (JIS C9612)
Cool InddB
38~31~26 41~34~28 46~42~32
Heat Ind 38~34~28 41~36~31 47~41~33
Sound Pressure Level (JIS C9612)
Outdoor dBA 60 63 63
Airflow Indoor L/S 150~126~96 153~130~106 191~160~110
External Dimensions (H x W x D)
Indoormm
600 x 860 x 238
Outdoor 595 x 780 (+62) x 290 640 x 800 (+71) x 290
Nett WeightIndoor
Kg18 19
Outdoor 38 45
Refrigerant Piping
Liquid Line
mm (in)
6.35 (1/4”)
Gas Line 9.52 (3/8”) 12.7 (1/2”)
Conn Method Flare
Refrigerant R410A QuantityKg 1.2 1.5
m Pre-charged for 15m of field piping
Max. Piping Length Overall/Height m 15 / 10 30 / 20
Features & Benefits
• Hi EER/COP ZJX Outdoor Units• Enzyme & Photocatalytic Filters• Self Clean Operation• Upper And Lower Air Outlet Selection
• Silicon Coated PCB• Superior Corrosion Resistance• 5 Year Warranty On Parts And Labour
96Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Air
Con
ditio
ning
Reverse Cycle Inverter Outdoor Units - R410ARealcoldStock No.
MitsubishiModel No.
Refrigerant Cap kW T1 Nominal~Range
No of Rooms
Max kW Cooling Connect
Largest Indoor Connect
ElectricSupply
Price$ Excl. GST
AC3301 SCM40ZJ-S R410A4.0 (1.8~5.9)
2 rooms 6.0kW 3.5kW 230/1/504.5 (1.4~6.9)
AC3302 SCM50ZJ-SI R410A5.0 (1.8~7.1)
2~3 rooms 8.5kW 5.0kW 230/1/506.0 (1.4~7.5)
AC3303 SCM60ZJ-SI R410A6.0 (1.8~7.5)
2~3 rooms 11.0kW 6.0kW 230/1/506.8 (1.5~7.8)
AC3304 SCM71ZJ-SI R410A7.1 (1.8~8.8) 2~4
rooms 12.6kW 6.0kW 230/1/508.6 (1.5~9.4)
AC3305 SCM80ZJ-SI R410A8.0 (1.8~9.2) 2~4
rooms 13.5kW 6.0kW 230/1/509.3 (1.5~9.8)
AC3306 SCM100ZJ-SI R410A10.0 (1.8~12.0) 4~5
rooms 16kW 7.1kW 230/1/5012.0 (1.5~13.5)
AC3307 SCM125ZJ-SI R410A12.5 (1.8~14.0) 4~6
rooms 19.5kW 7.1kW 230/1/5013.5 (1.5~14.0)
Multi Indoor Units - Wall MountRealcoldStock No.
MitsubishiModel No.
Refrigerant Nominal Cap kW Cool / Heat
DimensionsH x W x D
Airflow Max L/S
Ind Sound dBA
ElectricSupply
Price$ Excl. GST
AC3311 SRK20ZJ-SI R410A 2.0/2.7 294 x 798 x 229 130 33/27/21 230/1/50
AC3312 SRK25ZJ-SI R410A 2.5/3.2 294 x 798 x 229 131 34/28/21 230/1/50
AC3313 SRK35ZJ-SI R410A 3.5/4.0 294 x 798 x 229 168 42/32/22 230/1/50
AC3314 SRK50ZJ-SI R410A 5.0/5.8 294 x 798 x 229 188 46/37/26 230/1/50
AC3321 SRK20ZJX-S R410A 2.0/2.5 309 x 890 x 220 191 39/30/21 230/1/50
AC3322 SRK25ZJX-S R410A 2.5/3.1 309 x 890 x 220 208 41/31/22 230/1/50
AC3323 SRK35ZJX-S R410A 3.5/4.5 309 x 890 x 220 225 43/33/22 230/1/50
AC3324 SRK50ZJX-S R410A 5.0/5.8 309 x 890 x 220 225 47/40/27 230/1/50
AC3325 SRK60ZJX-S R410A 6.0/6.8 309 x 890 x 220 241 51/41/29 230/1/50
AIR CONDITIONINGSCM MULTI INVERTER SPLIT SYSTEM
97Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Air
Con
ditio
ning
Multi Indoor Units - Cassette & Bulk Head Ceiling Concealed Low StaticRealcoldStock No.
MitsubishiModel No.
Refrigerant Nominal Cap kW Cool / Heat
DimensionsH x W x D
Airflow Max L/S
Ind Sound dBA
ElectricSupply
Price$ Excl. GST
AC3331 FDTC25VF R410A 2.5/3.4 248 x 570 x 570 150 36/32/29 230/1/50
AC3332 FDTC35VF R410A 3.5/4.5 248 x 570 x 570 158 40/36/30 230/1/50
AC3333 FDTC50VF R410A 5.0/5.8 248 x 570 x 570 192 42/36/30 230/1/50
AC3334 FDTC60VF R410A 6.0/6.8 248 x 570 x 570 225 46/39/30 230/1/50
AC3341 SRR25ZJ-S R410A 2.5/3.4 230 x 740 x 455 142 40/35/29 230/1/50
AC3342 SRR35ZJ-S R410A 3.5/4.5 230 x 740 x 455 150 42/37/30 230/1/50
AC3343 SRR50ZJ-S R410A 5.0/5.8 230 x 740 x 455 175 48/42/33 230/1/50
AC3344 SRR60ZJ-S R410A 6.0/6.8 230 x 740 x 455 208 51/44/35 230/1/50
AC3345 FDUM50VF R410A 5.0/5.8 280 x 750 x 635 167 32/29/26 230/1/50
Multi Indoor Units - Floor MountRealcoldStock No.
MitsubishiModel No.
Refrigerant Nominal Cap kW Cool / Heat
DimensionsH x W x D
Airflow Max L/S
Ind Sound dBA
ElectricSupply
Price$ Excl. GST
AC3351 SRF25ZJX-S R410A 2.5/3.4 600 x 860 x 238 150 40/32/26 230/1/50
AC3352 SRF35ZJX-S R410A 3.5/4.5 600 x 860 x 238 153 41/34/28 230/1/50
AC3353 SRF50ZJX-SI R410A 5.0/5.8 600 x 860 x 238 191 46/42/32 230/1/50
AIR CONDITIONINGSCM MULTI INVERTER SPLIT SYSTEM
Mitsubishi Heat Pump AccessoriesRealcoldStock No.
MitsubishiModel No.
Description Price$ Excl. GST
AC3901 RCN-KIT3-E Infra red kit for FDUA / FDUM
AC3903 RCH-E3 Simple wired remote control - 2 wire
AC3904 SC-ADNA-E Superlink adapter for SRK and FD (RC-E5 / RC-EX1a)
AC3905 CnT Card connector flying leads
AC3906 SC-THB-E3 Remote sensor
AC3907 CW-H-E Base Heater kit for FD100VN, FDC125VNX-140VNX
AC3908 PCA006A057B PC Mente Interface (Pac Converters)
AC3910 SC-BIKN-EA Remote Control Interface for SRK (RC-E5 / RC-EX1a
AC3914 TC-PSA-25W-E FDTC Cassette Panel
AC3917 Resource Fee KX Commissioning per Unit
AC3919 RC-E5 Wired Remote Controller for All Indoor Units
AC3921 RC-EX1a Back Light ECO Touch Wired Controller
AC3922 RCN-E-E Infrared Receiver Kit For FDEN
AC3923 T-PSA-3BW-E FDT Cassette Panel
AC3924 RCN-TC-24W-ER Infrared Wireless Kit - FDTC
AC3925 RCN-T-36W-E Infrared Wireless Kit - FDT
98Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Air
Con
ditio
ning
Reverse Cycle Inverter Cassette - R410ARealcoldStock No.
MitsubishiModel No.
Refrigerant Cap kW T1 Nominal~Range
Noise dBAIND/OUT
Weight (Kg)IND/OUT
ElectricSupply
System Nett Price $ Excl
GST
AC3401 FDTC50ZJXVF R410A5.0 (2.2~5.6) 47~42~36~32 18.5
230/1/505.4 (2.5~6.3) 54 45
AC3402 FDT60ZJXVF R410A5.6 (2.8~6.3) 46~33~31~30 29.5
230/1/506.7 (3.1~7.1) 54 45
AC3403 FDT71VNXVF R410A7.1 (3.2~8.0) 46~35~33~31 29.5
230/1/508.0 (3.6~9.0) 51 60
AC3404 FDT100VNVF R410A10.0 (4.0~11.2) 51~40~37~35 32.5
230/1/5011.2 (4.0~12.5) 49 81
AC3405 FDT125VNXVF R410A12.5 (5.0~14.0) 51~42~40~37 32.5
230/1/5014.0 (4.0~17.0) 50 105
AC3406 FDT140VNXVF R410A14.0 (5.0~16.0) 51~43~41~38 32.5
230/1/5016.0 (4.0~18.0) 52 105
Note: Controllers are not included. Please select from RC-EX1a, RC-E5, RCN-T-36W-E or RCN-TC-24W-ER. See page 97.
Specifications - Reverse Cycle Inverter CassetteFDTC & FDT Cassette Series FDTC50VF
SRC50ZJX-SFDT60ZVFSRC60ZJX-S
FDT71VFFDC71VNX
FDT100VFFCT100VN
FDT125VFFDC125VNX
FDT140VFFDC140VNX
Power Supply 1 phase 230V 50Hz Outdoor Unit Outdoor Unit
CapacityCooling T1
kW5.0 (2.2~5.6) 5.6 (2.8~6.3) 7.1 (3.2~8.0) 10.0 (4.0~11.2) 12.5 (5.0~14.0) 14.0 (5.0~16.0)
Heating H1 5.4 (2.5~6.3) 6.7 (3.1~7.1) 8.0 (3.6~9.0) 11.2 (4.0~12.5) 14.0 (4.0~17.0) 16.0 (4.0~18.0)
InputCooling T1
kW1.56 1.52 2.04 2.76 3.28 4.19
Heating H1 1.45 1.87 1.94 2.74 3.43 4.20
Energy Label 2011Cooling
Stars2 2.5 1.5 1.5 2.0 1.5
Heating 2.5 2.5 3.0 3.0 3.0 2.5
AEER Cooling T1 3.20 3.68 3.48 3.62 3.81 3.34
ACOP Heating H1 3.72 3.94 4.12 4.09 4.08 3.81
CurrentCooling T1
Amp6.9 7.0 9.1 12.1 14.6 18.6
Heating H1 6.4 8.2 8.7 12.0 15.2 18.6
Recommended Circuit Breaker Amp 16 20 32Sound Pressure Level (JIS C9612)
Cool Ind dB 47~42~36~32 46~33~31~30 46~35~33~31 51~40~37~35 51~42~40~37 51~43~41~38
Sound Pressure Level (JIS C9612)
Outdoor dBA 47 54 54 49 50 52
Airflow Indoor L/S 225~191~150~133 466~300~266~233 466~350~316~283 616~450~400~333 616~500~450~383 616~500~450~383
Panel T-PSA-25W-E mm 35 x 700 x 700 T-PSA-3BW-E 35 x 950 x 950
External Dimensions (H x W x D)
Indoormm
248 x 570 x 570 246 x 840 x 840 298 x 840 x 840
Outdoor 640 x 800 x 290 750 x 880 x 340 845 x 970 x 370 1300 x 970 x 370
Nett WeightIndoor
Kg18.5 29.5 32.5
Outdoor 45 60 81 105
Refrigerant Piping
Liquid Linemm (in)
6.35 (1/4”) 9.52 (3/8”)
Gas Line 12.7 (1/2”) 15.88 (5/8”)
Conn Method Flare
Refrigerant R410A QuantityKg 1.5 2.95 3.8 4.5
m 15 30
Max. Piping Length Overall m 30 50 100
Controller RC-EX1a, RC-E5, RCN-TC-24W-ER or RCN-T-36W-E
AIR CONDITIONINGCASSETTE SPLIT SYSTEMS
99Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Air
Con
ditio
ning
Reverse Cycle Inverter Ducted - FDUM Medium StaticRealcoldStock No.
MitsubishiModel No.
Refrigerant Cap kW T1 Nominal~Range
Noise dBAIND/OUT
Weight (Kg)IND/OUT
ElectricSupply
System Nett Price $ Excl
GST
AC3601 FDUM50ZJXVF R410A5.0 (2.2~5.6) 37~26 29
230/1/505.4 (2.5~6.3) 50 45
AC3602 FDUM60ZJXVF R410A5.6 (2.8~6.3) 36~25 34
230/1/506.7 (0.6~7.1) 54 45
AC3603 FDUM71VNXVF R410A7.1 (3.2~8.0) 38~25 34
230/1/508.0 (3.6~9.0) 60 60
AC3604 FDUM100VNVF R410A10.0 (4.0~11.2) 44~30 54
230/1/5011.2 (4.0~12.5) 49 81
AC3605 FDUM125VNXVF R410A12.5 (5.0~14.0) 45~29 54
230/1/5014.0 (4.0~17.0) 50 105
AC3606 FDUM140VNXVF R410A14.0 (5.0~14.5) 47~30 54
230/1/5016.0 (4.0~18.0) 49 105
Note: Controllers are not included. Please select from RC-EX1a, RC-E5 or RCN-Kit3-E. See page 97.
Specifications - Reverse Cycle Inverter DuctedFDUM & FDU Ducted Medium Static Series
FDUM50VFSRC50ZJX-S
FDUM60VFSRC60ZJX-S
FDUM71VFFDC71VNX
FDUM100VFFDC100VNF
FDUM125VFFDC125VNX
FDUM140VFFDC140VNX
Power Supply 1 phase 230V 50Hz Outdoor Unit Outdoor Unit
CapacityCooling T1
kW5.0 (2.2~5.6) 5.6 (2.8~6.3) 7.1 (3.2~8.0) 10.0 (4.0~11.2) 12.5 (5.0~14.0) 14.0 (5.0~14.5)
Heating H1 5.4 (0.6~6.3) 6.7 (0.6~7.1) 8.0 (3.6~9.0) 11.2 (4.0~12.5) 14.0 (4.0~17.0) 16.0 (4.0~18.0)
InputCooling T1
kW1.56 1.75 2.2 2.92 3.6 4.4
Heating H1 1.7 2 2.2 3.2 3.9 4.54
Energy Label 2011Cooling
Stars2 2 2 2 2 1.5
Heating 3 2 2.5 2.5 3 2.5EER Cooling T1 3.21 3.2 3.23 3.42 3.47 3.18COP Heating H1 3.18 3.35 3.64 3.5 3.59 3.52
CurrentCooling T1
Amp6.7 8.2 9.6 12.7 15.3 18.6
Heating H1 6.3 9.0 9.5 13.1 16.3 19.1Recommended Circuit Breaker Amp 16 20 32Sound Pressure Level (JIS C9612)
Cool Ind dB 37~26 36~25 38~25 44~30 45~29 47~30
Sound Pressure Level (JIS C9612)
Outdoor dBA 50 54 60 49 50 49
Airflow Indoor L/S 217 ~ 133 333 ~ 167 400 ~ 166 600 ~ 317 650 ~ 330 800 ~ 367External Static Pressure
Indoor Pa 100 @ 217 l/s 100 @ 333 l/s 100 @ 400 l/s 100 @ 600 l/s 100 @ 650 l/s 100 @ 800 l/s
External Dimensions (H x W x D)
Indoormm
280 x 750 x 635 280 x 950 x 635 280 x 1370 x 740Outdoor 640 x 800 x 290 750 x 800 x 340 840 x 970 x 370 1300 x 970 x 370
Nett WeightIndoor
Kg29 34 34 54
Outdoor 45 60 81 105
Refrigerant PipingLiquid Line
mm (in)
6.35 (1/4") 9.52 (3/8”)Gas Line 12.7 (1/2") 15.88 (5/8”)Conn Method Flare
Refrigerant R410A QuantityKg 1.5 2.95 3.8 4.5m 15 30
Max. Piping Length Overall m 30 50 100Controller RC-E5, RC-EX1a or RCN-KIT3-E
AIR CONDITIONINGFDUM MEDIUM STATIC
100Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Air
Con
ditio
ning
Reverse Cycle Inverter Ducted - FDUA High StaticRealcoldStock No.
MitsubishiModel No.
Refrigerant Cap kW T1 Nominal~Range
Noise dBAIND/OUT
Weight (Kg)IND/OUT
ElectricSupply
System Nett Price $ Excl
GST
AC3613 FDUA71VNXVF R410A7.1 (3.2~8.0) 38~25 34
230/1/508.0 (3.6~9.0) 51 60
AC3614 FDUA100VNVF R410A10.0 (4.0~11.2) 43~37 52
230/1/5011.2 (4.0~12.5) 49 81
AC3615 FDUA125VNXVF R410A12.5 (5.0~14.0) 45~37 52
230/1/5014.0 (4.0~17.0) 48 105
AC3616 FDUA140VNXVF R410A14.0 (5.0~14.5) 47~40 52
230/1/5016.0 (4.0~18.0) 49 105
AC3617 FDUA160VSVF R410A16.0 (7.0~20.0) 49~42 52
415/3/5018.0 (7.6~22.4) 57 140
Note: Controllers are not included. Please select from RC-EX1a, RC-E5 or RCN-Kit3-E. See page 97.
Specifications - Reverse Cycle Inverter DuctedFDUA High Static Series FDUA71VF
FDC71VNXFDUA100VFFDC100VN
FDUA125VFFDC125VNX
FDUA140VFFDC140VNX
FDUA160VFFDC160VS
Power Supply Outdoor Unit 1 phase 230V 50Hz 415V / 3 / 50
CapacityCooling T1
kW7.1 (3.2~8.0) 10.0 (4.0~11.2) 12.5 (5.0~14.0) 14.0 (5.0~14.5) 16.0 (7.0~20)
Heating H1 8.0 (3.6~9.0) 11.2 (4.0~12.5) 14.0 (4.0~17.0) 16.0 (4.0~18.0) 18.0 (7.6~22.4)
InputCooling T1
kW2.22 3.05 3.83 4.44 5.02
Heating H1 2.22 2.87 3.68 4.41 4.96
Energy Label 2011Cooling
Stars1.5 2 2 1.5 1.5
Heating 2.5 3 3 2.5 2.5
EER Cooling T1 3.2 3.28 3.26 3.15 3.19
COP Heating H1 3.6 3.90 3.8 3.63 3.63
CurrentCooling T1
Amp9.4 13 16.3 18.9 7.6
Heating H1 9.4 12.2 15.6 18.8 7.5
Recommended Circuit Breaker Amp 20 32 25Sound Pressure Level (JIS C9612)
Cool Ind dB 38~25 43~37 45~37 47~40 49~42
Sound Pressure Level (JIS C9612)
Outdoor dBA 51 49 48 49 57
Airflow Indoor L/S 400 650 717 850 850External Static Pressure
Indoor Pa 200
External Dimensions (H x W x D)
Indoormm
280 x 950 x 635 398 x 1150 x 650
Outdoor 750 x 880 x 340 845 x 970 x 370 1300 x 970 x 370 1505 x 970 x 370
Nett WeightIndoor
Kg34 52
Outdoor 60 81 105 140
Refrigerant Piping
Liquid Linemm (in)
9.52 (3/8”) 12.7 (1/2")
Gas Line 15.88 (5/8”) 22.2 (7/8")
Conn Method Flare Brazed
Refrigerant R410A QuantityKg 2.95 3.8 4.5 7.2
m 30
Max. Piping Length Overall/Height m 50 100 70
Controller RC-E5, RC-EX1a or RCN-KIT3-E
AIR CONDITIONINGFDUA HIGH STATIC
101Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Air
Con
ditio
ning
Reverse Cycle Inverter Under Ceiling - FDENRealcoldStock No.
MitsubishiModel No.
Refrigerant Cap kW T1 Nominal~Range
Noise dBAIND/OUT
Weight (Kg)IND/OUT
ElectricSupply
Price$ Excl. GST
AC3702 FDEN100VNVF R410A10.0 (4.0~11.2) 46~44~41~39 49
230/1/5011.2 (4.0~12.5) 49 81
AC3703 FDEN125VNXVF R410A12.5 (5.0~14.0) 50~46~44~43 49
230/1/5014.0 (4.0~17.0) 50 105
Note: Controllers are not included. Please select from RC-EX1a, RC-E5 or RCN-E-E. See page 97.
Specifications - Reverse Cycle Inverter Under CeilingFDUM & FDU Ducted Medium Static Series FDEN100VF
FDC100VNFDEN125VFFDC125VNX
Power Supply 1 phase 230V 50Hz Outdoor Unit
CapacityCooling T1
kW10.0 (4.0~11.2) 12.5 (5.0~14.0)
Heating H1 11.2 (4.0~12.5) 14.0 (4.0~17.0)
InputCooling T1
kW2.85 3.86
Heating H1 2.97 3.77
Energy Label 2011Cooling
Stars2 1
Heating 2.5 2
AEER Cooling T1 3.51 3.23
ACOP Heating H1 3.77 3.71
CurrentCooling T1
Amp12.5 17.1
Heating H1 13.0 16.7
Recommended Circuit Breaker Amp 32 32
Sound Pressure Level (JIS C9612) Cool Ind dB 46~44~41~39 50~46~44~43
Sound Pressure Level (JIS C9612) Outdoor dBA 49 50
Airflow Indoor L/S 466~433~383~350 533~483~433~383
External Dimensions (H x W x D)
Indoormm
250 x 1620 x 690 250 x 1620 x 690
Outdoor 845 x 970 x 370 1300 x 970 x 370
Nett WeightIndoor
Kg49 49
Outdoor 81 105
Refrigerant Piping
Liquid Line
mm (in)
9.52 (3/8”)
Gas Line 15.88 (5/8”)
Conn Method Flare
Refrigerant R410A QuantityKg 3.8 4.5
m 30 30
Max. Piping Length Overall/Height m 50 100
Controller Not Included Standard RC-E5, RC-EX1a, RCN-E-E
AIR CONDITIONINGUNDER CEILING SPLIT SYSTEMS
102Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Air
Con
ditio
ning
AIR CONDITIONINGGREE INTRODUCTION
Gree Air Conditioning
For comfortable, cleaner and healthier living and working environments choose Gree and put your trust in the world’s largest producer of air conditioning and heating units.
With more than 200 million users in 200 countries, Gree is a genuine global leader with unsurpassed expertise and manufacturing capability, producing intelligent, energy efficient air conditioning systems for all climates and conditions.
Small wonder Gree has been the world’s number one in residential air conditioning since 2005.
103Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Air
Con
ditio
ning
Reverse Cycle Window-Wall Remote ControlRealcoldStock No.
GreeModel No.
Refrigerant Cap kWNominal
Noise dBAHigh/Low
Weight (Kg) ElectricSupply
Price$ Excl. GST
AC5025 GJH09AF-K3RNB9D R410A2.7 49
44 230/1/502.4 45
AC5026 GJH12AD-K3RNB9D R410A3.9 53
57 230/1/503.6 49
AC5027 GJH18AC-K3RNB9D R410A5.3 55
68 230/1/505 51
AC5028 GJH21AC-K3RNB9D R410A6 56
70 230/1/505.5 52
Features & Benefits
• Exceeds the 2012 MEPS IV annulised ratings• R410A Refrigerant• 4 Way Air Flow• Easy Clean Filter• Remote Control• 5 Year Parts and Labour Warranty, domestic use only
• 4 Way Air Flow • Long distance airing
• Easy Cleaned Filter• Economic Sleep Mode
Specifications - Gree Coolani Window-Wall SeriesGree Coolani Window-Wall Series GJH09AF-
K3RNB9DGJH12AD-K3RNB9D
GJH18AC-K3RNB9D
GJH21AC-K3RNB9D
Power Supply 1 phase 230V 50Hz
CapacityCooling T1
kW2.7 3.9 5.3 6
Heating T1 2.4 3.6 5 5.5
InputCooling T1
kW0.81 1.18 1.6 1.83
Heating T1 0.72 1.09 1.5 1.76
Energy Label 2011Cooling
Stars2 2 2 2
Heating 2 2 2 1.5
AEER Cooling T1 3.27 3.36 3.28 3.27
ACOP Heating T1 3.25 3.41 3.25 3.17
Current Cooling T1 Amp 5.1 7.3 9.1 10.1
Recommended Circuit Breaker Amp 10 15
Sound Pressure Level (JIS C9612)
HighdBA
49 53 55 56
Low 45 49 51 52
Airflow Indoor L/S 133 188 239
External Dimensions (H x W x D)
Indoor mm 375 x 560 x 668 428 x 660 x 700 428 x 660 x 770
Nett Weight Kg 44 57 68 70
Refrigerant R410A Pre-charged Kg 0.75 1.1 1.3 1.34
AIR CONDITIONINGWINDOW-WALL SERIES
104Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Air
Con
ditio
ning
Reverse Cycle Hi-Wall - CozyRealcoldStock No.
GreeModel No.
Refrigerant Cap kWNominal
Noise dBAIND/OUT
Weight (Kg)IND/OUT
ElectricSupply
Price$ Excl. GST
AC7180 GWH09MB-K3DNA*H R410A2.6 40~32 11
230/1/502.8 50 32
AC7181 GWH12MB-K3DNA*H R410A3.5 42~33 11
230/1/503.85 52 36
AC7182 GWH18MC-K3DNA*H R410A5.2 46~35 13
230/1/505.85 56 44
AC7183 GWH24MD-K3DNA*H R410A6.3 51~39 16
230/1/506.3 56 50
AC7184 GWH24ME-K3DNA*H R410A7 51~40 17.5
230/1/507.5 59 65
Features & Benefits
• Gree 180° Sine Wave Inverter Technology• iFeel indoor temperature control• Exceeds the 2011 MEPS IV annulised ratings• 5 metre connection cable included• Healthy filter options• 5 Year Parts and Labour Warranty, domestic use only
• Optional Filters• iDefrosting
• iFeel • Easy Clean Flat Panel
Specifications - Gree Cozy Hi-Wall Split SystemsGree Cozy Hi-Wall Split Systems GWH09MB-
K3DNA*HGWH12MB-K3DNA*H
GWH18MC-K3DNA*H
GWH24MD-K3DNA*H
GWH24ME-K3DNA*H
Power Supply 1phase 230V 50Hz Indoor Unit Outdoor Unit
CapacityCooling T1
kW2.6 3.5 5.2 6.3 7
Heating T1 2.8 3.85 5.85 6.3 7.5
InputCooling T1
kW0.73 0.98 1.59 1.93 2.14
Heating T1 0.78 1.07 1.79 1.93 2.28
Energy Label 2011Cooling
Stars2.5 2.5 1.5 1.5 1.5
Heating 2.5 2.5 1.5 1.5 1.5
AEER Cooling T1 3.57 3.57 3.09 3.18 3.17
ACOP Heating T1 3.63 3.72 3.14 3.07 3.14
Current Cooling T1 Amp 3.2 / 3.5 4.3 / 4.7 7.0 / 7.9 8.6 / 8.6 10.1 / 10.8
Recommended Circuit Breaker Amp 10 15 20
Moisture Removal L/H 0.8 1.2 1.8 2.5
Sound Pressure Level (JIS C9612)
IndoordBA
40~32 42~33 46~35 51~39 51~40
Outdoor 50 52 56 59
Airflow Indoor L/S 161 166 236 263 333
External Dimensions (H x W x D)
Indoormm
275 x 845 x 180 298 x 940 x 200 315 x 1007 x 219 326 x 1178 x 253
Outdoor 540 x 776 x 320 592 x 848 x 320 700 x 955 x 396 790 x 920 x 428
Nett WeightIndoor
Kg11 13 16 17.5
Outdoor 32 36 44 50 65
Refrigerant Piping
Liquid Line
mm (in)
6.35 (1/4”)
Gas Line 9.52 (3/8") 12.7 (1/2") 15.88 (5/8")
Conn Method Flare
Refrigerant R410A QuantityKg 0.87 1.26 1.2 1.9 1.8
m 7.5
Max. Piping Length Overall/Height m 10/15 10/20 10/25
AIR CONDITIONINGCOZY HI-WALL INVERTER
105Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Air
Con
ditio
ning
Reverse Cycle Inverter Hi-Wall - HansolRealcoldStock No.
GreeModel No.
Refrigerant Cap kWNominal~Range
Noise dBAIND/OUT
Weight (Kg)IND/OUT
ElectricSupply
Price$ Excl. GST
AC7301 GWH09TA-K3DNA1B R410A2.6 (0.57~3.2) 37~21 10
230/1/503.0 (0.57~3.2) 50 34
AC7302 GWH12TB-K3DNA1B R410A3.5 (0.66~3.9) 39~23 11
230/1/504.0 (0.7~4.3) 52 36
AC7303 GWH18TC-K3DNA1B R410A5.3 (0.7~6.5) 45~30 16
230/1/505.8 (0.95~7.3) 56 50
AC7304 GWH24TD-K3DNA1B R410A7.0 (1.2~8.0) 49~36 18
230/1/507.6 (1.4~10) 56 68
AC7305 GWH28TD-K3DNA1B R410A8.0 (1.0~8.8) 49~36 18
230/1/508.4 (1.3~11) 58 69
Features & Benefits
• G10 Inverter, Lowest Energy Consumption• Seven speed indoor fan motors, Ultra Low Noise• Exceeds the 2012 MEPS IV annulised ratings• 5 metre connection cable included• Healthy filter options• 5 Year Parts and Labour Warranty, domestic use only
• iFeel• 8°C Heating
• G10 Inverter • iDefrosting
Specifications - Gree Hansol Hi-Wall Inverter Split SystemsGree Hansol Hi-Wall Inverter Split Systems GWH09TA-
K3DNA1BGWH12TB-K3DNA1B
GWH18TC-K3DNA1B
GWH24TD-K3DNA1B
GWH28TD-K3DNA1B
Power Supply Indoor Unit 1 phase 230V 50Hz
CapacityCooling T1
kW2.6(0.57~3.2) 3.5(0.66~3.9) 5.3(0.7~6.5) 7.0(1.2~8.0) 8.0(1.0~8.8)
Heating T1 3.0(0.57~3.2) 4.0(0.7~4.3) 5.8(0.95~7.3) 7.6(1.4~10) 8.4(1.3~11)
InputCooling T1
kW0.67 0.9 1.52 2 2.39
Heating T1 0.77 1.03 1.66 2.17 2.51
Energy Label 2011Cooling
Stars3 3 2 2 2
Heating 3 3 2 2 2
AEER Cooling T1 3.86 3.77 3.27 3.48 3.36
ACOP Heating T1 3.84 3.86 3.29 3.47 3.27
Current Cooling T1 Amp 2.91/3.35 3.91/4.48 7.28/8.09 8.87/9.63 10.6/11.14
Recommended Circuit Breaker Amp 10 15 20
Moisture Removal L/H 0.8 1.4 1.8 2.5 2.7
Sound Pressure Level (JIS C9612)
IndoordBA
37/32/28/25/23/21 39/34/31/28/26/23 45/41/39/36/33/30 49/45/43/41/39/36 49/45/43/41/39/36
Outdoor 50 52 56 58
Airflow Indoor L/S 153 208 264 333 333
External Dimensions (H x W x D)
Indoormm
292 x 806 x 209 292 x 866 x 209 319 x 1018 x 230 326 x 1178 x 264
Outdoor 540 x 848 x 320 592 x 848 x 320 700 x 955 x 396 790 x 980 x 427
Nett WeightIndoor
Kg10 11 16 18
Outdoor 34 36 50 68 69
Refrigerant Piping
Liquid Line
mm (in)
6.35 (1/4”)
Gas Line 9.52 (3/8") 15.88 (5/8")
Conn Method Flare
Refrigerant R410A QuantityKg 1.07 1.25 1.6 2.3 2.4
m 7.5
Max. Piping Length Overall/Height m 15/10 20/10 25/10
AIR CONDITIONING HANSOL HI-WALL INVERTER
106Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Air
Con
ditio
ning
Floor Console SeriesRealcoldStock No.
GreeModel No.
Refrigerant Cap kWNominal
Min~max Noise dbA In / Out
Weight (Kg)In / Out
ElectricSupply
Price$ Excl. GST
AC7403 GEH18AA-K3DNA1A R410AC5.2 C0.9~5.6 48~32 15
230/1/50H5.3 H0.9~6.6 54 49
AIR CONDITIONINGFLOOR CONSOLE
Specifications - Inverter Split SystemsGree Consol Inverter Split Systems
Power Supply 1 phase 230V 50Hz Indoor Unit
CapacityCooling T1
kW5.2 (0.9~5.6)
Heating H1 5.3 (0.9~6.6)
InputCooling T1
kW1.68
Heating H1 1.63
Energy Label 2011Cooling
Stars1.5
Heating 2.5
EER Cooling T1 3.14
COP Heating H1 3.61
CurrentCooling T1 Amp 7.6
Heating H1 7.0
Recommended Circuit Breaker Amp 15
Sound Pressure Level (JIS C9612)
Cool InddB
48~32
Heat Ind 54
Airflow Indoor L/S 180
External Dimensions (H x W x D)
Indoormm
600 x 700 x 215
Outdoor 700 x 995 x 396
Nett WeightIndoor
Kg15
Outdoor 49
Refrigerant Piping
Liquid Line
mm (in)
6.35 (1⁄4”)
Gas Line 12 (1⁄2”)
Conn Method Flare
Refrigerant R410A Pre-charged amount
Kg 1.33m 5
Max. Piping Length Overall/Height m 25/10
Features & Benefits
• iFeel Remote Control
• 8°C Heating
• Seven Speed indoor fan motor
• Twin Air-flow
• Quiet Design
• Wall Mounted or Half Concealed
• Exceeds the 2012 MEPS IV annulised ratings
• Healthy filter options
• 5 Year Parts and Labour Warranty, domestic use only
107Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Air
Con
ditio
ning
AIR CONDITIONINGAIR CURTAINS & ENERGY RECOVERY
Gree Air CurtainsRealcoldStock No.
EclipseModel No.
Dimesions (mm)
Installation Height (m)
Input Power Watts
Air Speed (m/sec)
Noise dBA
Weight Nett (Kg)
ElectricSupply
Price$ Excl. GST
Min Max
AC7509 FM-1.25-9-K 900x215x193 2.3 3.0 110 8 59 16 230/1/50
AC7512 FM-1.25-12-K 1200x215x193 2.3 3.0 140 8 61 20 230/1/50
Features & Benefits
• Optimized cross-flow fan and high performance motor utilised
• Micro processor controlling with high reliability and long service
• Anti-corrosion thanks to two sided painted electro-galvanised metal case
• High quality galvanised steel casing with double sided plastic spray processing, high anti-corrosion
• Integrated electric components, easy maintenance
• High performance cross flow fan blade with 3D-optimised streamlining
• Remote control
RealcoldStock No.
GreeModel No.
Airflow (m3/hr) Max. External Static Pressure
ElectricSupply
System Price$ Excl. GST
AC5322 FHBQ-D3.5-K High 350 100
220V~1Ph~50HzAC5324 FHBQ-D5-K High 500 100
AC5326 FHBQ-D8-K High 800 110
AC5328 FHBQ-D10-K High 1000 110
AC5330 FHBQ-D15-M High 1500 150
380V ~ 3Ph ~50HzAC5332 FHBQ-D20-M High 2000 150
AC5334 FHBQ-D30-M High 3000 220
Note: All units come with a simplified wired controller. Humidity Sensor Optional.
Gree Energy - Recovery Ventilation Systems
This Energy-Recovery Ventilation Systems supplies modulated fresh air to improve the indoor air quality. The high heat exchange efficiency offers up to 70% temperature exchange efficiency. Heat recovery ventilation systems can reduce the loading on air conditioners / heat pumps by 26%, based on annual operation.
High Heat Exchanger EfficiencyRemarkable Energy Savings7 models available from 97 - 833 l/sFlexible Control Functions
o 50 - 50 air discharge / supply
o Positive or negative room pressure
o Weekly control for on - off timer
o Humidity control (optional)
o Centralized Remote Control (optional)
Long Distance Control (optional)Easy installation & maintenanceLong life and washable filters and heat exchanger
108Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Air
Con
ditio
ning
Ducting & AccessoriesThis attractive ivory coloured ducting is easy to install. The slim, square design of the duct and accessories has an aesthetic appearance which will enhance any installation. The duct is made of highly durable, weatherproof PVC resin. Suitable for use in the temperature range -20 to +60ºC
RealcoldStock No.
Model Description Carton Quantities
Price$ Excl. GST
AC0201 TD-80 80 mm Duct sold in 2 metre lengths 5
AC0202 TD-120 120 mm Duct sold in 2 metre lengths 4
Ducting is packed 5 lengths (AC0201) or 4 lengths (AC0202) to a carton
AC0206 DC-80 80 mm Cap 20
AC0207 DC-120 120 mm Cap 10
AC0209 DK-80 80 mm Corner 20
AC0210 DK-120 120 mm Corner 6
AC0212 DF-80S 80 mm Flexible Joint 20
AC0213 DF-120 120 mm Flexible Joint 5
AC0215 DLW-80 80 mm 45º Elbow 20
AC0217 DL-80 80 mm 90º Elbow 20
AC0218 DL-120 120 mm 90º Elbow 10
AC0220 DJ-80 80 mm Joint 50
AC0221 DJ-120 120 mm Joint 20
AC0223 DE-80 80 mm End Socket 20
AC0224 DS-80 80 mm Ceiling Cap 20
AC0225 DT-120 120 mm T-Joint 5
AC0226 DB-120 120 mm Branch Joint 5
AC0227 DR-120 120 mm Reducing Joint 10
AC0228 WPC-60 Wall Pipe with Flange 60
AC0229 DS-120 120 mm Duct Ceiling Cap 10
RealcoldStock No.
Model Description Carton Quantities
Price$ Excl. GST
AC0501 HB-330 Mounting Base, Ivory 330 mm 50
AC0503 HB-450 Mounting Base, Ivory 450 mm 30
AC0510 BBB-36 Quick Base 360 mm 20
AC0512 BBB-45 Quick Base 450 mm 20
AC0702 PT-1K Sealing Putty, Flame proof, 1Kg pack 20
AC0709 VT50 X 20 Self-Adhesive Tape, Ivory 80
A mounting base which is designed to maintain the aesthetic qualities of the installation. The sophisticated design, lightweight, rigidity and portability give a considerable advantage over other mounting methods. Made of rigid, waterproof resin, it is suitable for use in the temperature range -20 to +60ºC.
AC0512 / AC0510
AC0206/AC0207
AC0501/AC0503
AC0201/AC0202
AC0209/AC0210
AC0212 / AC0213
AC0224 / AC0229
AC0225
AIR CONDITIONINGACCESSORIES
109Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Air
Con
ditio
ning
Mounting Brackets & BasesRealcoldStock No.
Model Description Price$ Excl. GST
AC0603 AH-YDIISloped Roof Bracket - For 5.0kW or smallerWidth 250 - 700 mm Depth 100 - 360 mm Slope 11° - 30° Max weight 75 Kg
AC0609 QKYL-1Sloped Roof Bracket - For 3.5kW or smallerWidth 150 - 550 mm Depth 230 - 700 mm Slope 10° - 30° Max weight 60 Kg
AC0611 QKK-1Wall Type - For 3.5kW or smallerWidth 250 - 760 mm Wall Mount 1000 mm Max weight 60 Kg Arms 400 mm
AC0613 AH-KLWall Type - For 5.0kW or smallerWidth 330 - 630 mm Depth 130 - 360 mm Max weight 75 Kg
AC1310 CHBRCB-18Wall Type 1.5 mm Painted SteelArms 450 mm Wall Mount 800 mm Max Weight 80 Kg
AC1311 CHBRCB-25Wall Type 2.0 mm Painted SteelArms 500 mm Wall Mount 1,000 mm Max Weight 100 Kg
AC1301 CHBRCB-10SRealcold S/S Wall Type - 1.5 mmArms 480 mm Wall mount 750 mm Max Weight 75 Kg Stainless Steel 304
AC1302 CHBRCB-20SRealcold S/S Wall Type - 2.0 mmArms 600 mm Wall mount 1,000 mm Max Weight 100 Kg Stainless Steel 304
AC1303 CHBRRB-10S
Realcold S/S Roof Type - 1.5 mmCan be used as a wall bracketArms 480 mm Roof mount 800 mm Max Weight 75 Kg Stainless Steel 304
AC1304 CHBRRB-20S
Realcold S/S Roof Type - 2.0mmCan be used as a wall bracketArms 550 mm Roof mount 1,000 mm Max Weight 100 Kg Stainless Steel 304
AC1200 MCB450 - 450 mm Medium duty galvanised cantilever bracket
AC1201 HCB450 - 630 mm Heavy duty galvanised cantilever bracket
AC1208 Kit 1 c/w 4 x 10 mm coach bolts, 4 x SNL-M8 channel spring nuts, 4 x M8 bolts, 2 x end caps
AC1209 Kit 2 c/w 4 x 10 mm dyna bolts, 4 x SNL-M8 channel spring nuts, 4 x M8 bolts, 2 x end caps
AC1205 M1000 Galvanised steel channel - 3 metre length
AC1215 SNL-M8 8 mm channel spring nut
AC1216 SNL-M10 10 m channel spring nut
AC1220 PS465 Polyslab - Medium
Refer to page 113 for Roof Penetration Kit - compliant with NZ Metal Roofing Code of Practise.
AH-YDII
QKYL-1
QKK-1
AH-KL
Stainless Steel Channels
HCB450
MCB450
AIR CONDITIONINGACCESSORIES
110Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Air
Con
ditio
ning
Hi Lift PumpsRealcoldStock No.
Description Price$ Excl. GST
T0912
Aspen Hi Lift Tank Pump 2.0 Litre TankDescription: Peristaltic Rotary Type Pump. Designed to collect and pump a smaller volume of water to a greater head. Requires 230V supply only. Fits into a shallow ceiling void or unit.Features: No siphoning back. Clear deck for quick and easy inpection. Incorporated back plate for vertical mounting. Pre-wired safety switch. 2 x 25 mm inlet positions. Made of fire retardant plastics. Pumps water, fibrously contaminated water and air.Technical: Pump rating 1ph, 0.4A, 230 VAC, 50Hz. Safety switch 4.0A max. Water flow rate 11 l/hr @ 12 metres head. Max head is 12 metres. Inlet 2 x 25 mm, outlet size is 6mm. Tank capacity 2.0 litres.Dimensions: 165 mm high x 235 mm wide x 140 mm deep. Weight 2.0Kg.
AIR CONDITIONINGCONDENSATE PUMPS
Hi Flow Pumps 1.0 LitreRealcoldStock No.
Description Price$ Excl. GST
T0913
Aspen Hi-Flow Condensate Pump 1.0 LitreDescription: Centrifugal Type Pump. Designed to collect and pump a high volume of water to a lesser head. Requires 230V supply only. In all cases the hi-flow pump must be sited under the source of the condensate.Features: In-line valve to prevent siphoning back. Clear deck for quick and easy inpection. Incorporated back plate for vertical mounting. Pre-wired safety switch. 2 x 25 mm inlet positions. Made of fire retardant plastics. Auto re-setting thermal cut-out to shaded pole motor. Conecting cable 2 metres.Technical: Pump rating 1ph, 0.2A, 230VAC, 50 Hz. Safety switch 4.0A max. Discharge head 4 metres max. Water pumping capacity 288 L/H max. Tank capacity 1.0 litre.Dimensions: 130 mm high x 235 mm wide x 140 mm deep. Weight 1.8Kg.
111Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Air
Con
ditio
ning
Universal PumpRealcoldStock No.
Description Price$ Excl. GST
T0916
Aspen Universal PumpDescription: Peristaltic Rotary Type Pump. Self priming to 3m. Pumps water, fibrously contaminated water and air. Requires two sensores to read air on/off on the evaporator coil.Features: Operates by sensing 5°C differential across the evaporating coil. 3 minute timer overrun on stop. No siphoning back. Operates only on cooling. Manual test switch. 3m connecting cable. Wall mounting bracket included. Made of fire retardant plastics.Technical: Pump rating 1ph, 0.2A, 230 VAC, 50Hz. Water flow rate 6.25 l/hr @ 12 metres head. Max head is 12 metres. Inlet / outlet size is 6 mm.Dimensions: 115 mm high x 135 mm wide x 77 mm deep. Weight 1.35Kg.
Note: Condensate Pans refer to page 193. Actabs refer to page 183.
AIR CONDITIONINGCONDENSATE PUMPS
Hi Flow Pumps 2.0 LitreRealcoldStock No.
Description Price$ Excl. GST
T0914
Aspen Hi-Flow Condensate Pump 2.0 LitreDescription: Centrifugal Type Pump. Designed to collect and pump a high volume of water to a lesser head. Requires 230V supply only. In all cases the hi-flow pump must be sited under the source of the condensate.Features: In-line valve to prevent siphoning back. Clear deck for quick and easy inpection. Incorporated back plate for vertical mounting. Pre-wired safety switch. 2 x 25 mm inlet positions. Made of fire retardant plastics. Auto re-setting thermal cut-out to shaded pole motor. Conecting cable 2 metres.Technical: Pump rating 1ph, 0.2A, 230VAC, 50 Hz. Safety switch 4.0A max. Discharge head 4 metres max. Water pumping capacity 288 L/H max. Tank capacity 2.0 litres.Dimensions: 165 mm high x 235 mm wide x 140 mm deep. Weight 2.0Kg.
112Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Air
Con
ditio
ning
Compact Pumps - Hidden InstallationRealcoldStock No.
Description Price$ Excl. GST
T0939
Aspen Mini AquaFeatures: Our smallest pump ever fits all wall mount splits. 3A volt free alarm wires, NO NC contacts rated at 5A inductive at 230V. Hall effect semi conductor level sensors, with high level safety. Thermally protected. Mounts vertically or horizontally, Versatile and quiet operation.Technical: Pump rating 1ph, 0.2A, 230VAC, 50Hz, 16 watts. Water flow rate 14 l/hr @ zero head. Max head 8 metres. 21 dBA @ 1 metre.Dimensions: 28 mm high x 165 mm wide x 28 mm deep. Weight 0.18Kg.
T0940
Aspen Mini OrangeFeatures: Designed to be installed above ceilings, behind wall mounted evaporators and in plastic conduit. 3A volt free alarm wires, NO NC contacts rated at 5A inductive at 230V. Hall effect semi conductor level sensors, with high level safety. Thermally protected. Both pump and reservoir must be mounted flat. Technical: Pump rating 1ph, 0.2A, 230VAC, 50Hz, 16 watts. Water flow rate 14 l/hr @ zero head. Max head 8 metres. Suction lift 1 metre. 2 dBA @ 1 metre.Dimensions: 51 mm high x 107 mm wide x 39 mm deep. Weight 0.25Kg.
T0941
Aspen Maxi OrangeFeatures: Designed to be installed above ceilings, behind wall mounted evaporators and in plastic conduit. 3A volt free alarm wires, NO NC contacts rated at 5A inductive at 230V. Hall effect semi conductor level sensors, with high level safety. Thermally protected. Both pump and reservoir must be mounted flat. Technical: Pump rating 1ph, 0.25A, 230VAC, 50Hz, 18 watts. Water flow rate 37 l/hr @ zero head. Max head 20 metres. Suction lift 1 metre. 35 dBA @ 1 metre.Dimensions: 66 mm high x 122 mm wide x 44 mm deep. Weight 0.45Kg.
T0942
Aspen Mini LimeFeatures: Designed to be installed in the plastic conduit supplied. 3A volt free alarm wires, NO NC contacts rated at 5A inductive at 230V. Hall effect semi conductor level sensors, with high level safety. Thermally protected. Reversible. Box contains the pump, elbow, 800m conduit, connection sleeve and ceiling plate.Technical: Pump rating 1ph, 0.2A, 230VAC, 50Hz, 18 watts. Water flow rate 12 l/hr @ zero head. Max head 10 metres. 23 dBA @ 1 metre.Dimensions: 79 mm high x 99 mm wide x 44 mm deep. Weight 0.31Kg.
Anti Siphoning Device - Revolution From Aspen
• The leading solution to prevent siphoning • Even faster and easier installations
• Hassle free condensate pump fitting • Unique and revolutionary design
• Complete peace of mind • Exclusively free with Aspen Mini Pumps
AIR CONDITIONINGCONDENSATE PUMPS
113Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Air
Con
ditio
ning
Heat Pump AccessoriesRealcoldStock No.
Description Price$ Excl. GST
AC1701 Universal Remote Control for A/C Ultra Plus Hi-wall
ACSG0441 Gree Basic Remote
ACSG0651 Gree iFeel Remote
ACSG0664 Gree Hansol Remote
ACSG0630 Gree RAC Remote
N0495 65 mm Roof Penetration Kit - Top Hat (see below)
N0496 110 mm Roof Penetration Kit - Top Hat (see below)
Top Hat Roof Penetration Kit contains: • Decktite flexible flashing• PVC slotted pipe• PVC cover flashing• PVC cap• 12 hex head screws• Bostik sealant• Complies with NZ Metal Roofing Code of Practise
Spares for PumpsRealcoldStock No.
Description Price$ Excl. GST
T0905 Peristaltic Tubes
T0920 6 mm Clear Plastic Tubing for condensate pumps
T0922 Aspen non-return valve 6 mm
T0924 Aspen straight connector
T0926 In Line Filter 16 mm
T0925 In Line Filter 6 mm
T0928 Aspen Universal Sensor
Compact Pumps - Below Wall Unit InstallationRealcoldStock No.
Description Price$ Excl. GST
T0938
Aspen Mini Blanc Pump DeluxeFeatures: Designed to sit below the indoor unit. Offers easy access for fast efficient servicing. 3A volt free alarm wires, NO NC contacts rated at 5A inductive at 230V. Hall effect semi conductor level sensors, with high level safety. Thermally protected. Cleanable / replacable 70 micron internal filter.Technical: Pump rating 1ph, 0.2A, 230 VAC, 50Hz, 16 watts. Alarm relay rated at 5A / 250VAC. Max water flow rate, 12 l/hr @ zero head. Max head 10 metres, 21 dBA @ 1m.Dimensions: 115 mm high x 182 mm wide x 55 mm deep. Weight 0.46Kg.
AIR CONDITIONINGCONDENSATE PUMPS
AC1701
ACSG0651
114Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Air
Con
ditio
ning
Electrical & ThermostatsRange of electrical components to assist air conditioning installers.
RealcoldStock No.
Description Base Unit of Measure
Price$ Excl. GST
E2012 2.5 mm, 3 Core TPS, 2C + Earth Metre
E2026 1.5 mm, 4 Core TPS, 3C + Earth Metre
E2024 2.5 mm, 4 Core TPS, 3C + Earth Metre
E2023 Flex 25 mm Conduit Metre
E1096 Switch On/Off IP66 20A IPO Each
Capacitors
ACSG0061 25mfd / 450V Capacitor
ACSG0093 30mfd / 450V Capacitor
ACSG0275 35mfd / 450V Capacitor
ACSG0175 40mfd / 450V Capacitor
ACSG0285 45mfd / 450V Capacitor
ACSG0035 50mfd / 450V Capacitor
ACSG0255 60mfd / 450V Capacitor
ACSG0571 60mfd / 370V Capacitor
ACSG0340 98mfd / 330V Capacitor
Seitron Air Conditioning ThermostatsRealcoldStock No.
Model No Description Price$ Excl. GST
Electronic Thermostats (Heatpumps)
G4520 TAEZN4MC Elec. Heatpump t/stst 230V AC - Use STLNTSA150 Sensor
G4521 TAEZN42C Elec. Heatpump t/stst 24V AC - Use STLNTSA150 Sensor
G4522 TAEZN2MC Electronic Heatpump t/stst 230V AC On / Off Switch - Use STLNTSA150 Sensor
G4523 TFEZN4MC Electronic Heatpump t/stst 230V AC On / Off & 3 Speed Fan Switches - Use STLNTSA150 Sensor
G4524 TFPF03MC Diamond Electronic programable Heat pump t/stat with Digital display, 230V AC - Use STLNTSA150 Sensor
Mechanical Heating / Cooling Thermostats
G4525 TAM011MI TAM, 16A Heating / 5A Cooling 8…30°C 230V AC
G4526 TAM013MI TAM, 5A 8…30°C 230V AC On / Off Switch
Electronic Heating Thermostat
G4527 Magictime Programable heating t/stat, 7 day/24hr digital analogue display - use STLOTPA150 NTC Sensor
Sensors and Accessories
G4553 STANP3 NTC Room Sensor for TAEZN / TFEZN series t/stats
G4554 Sensor Housing Plastic Sensor Housing
G4555 STLNTSA150 Remote NTC Sensor - Probe 1.5m lead 4.7 Kohm @ 25°C
G4556 STLOTPA150 Magictime Remote NTC Sensor 100 Kohm @ 25°C
AIR CONDITIONINGELECTRICAL & THERMOSTATS
G4520
G4527
G4525
G4524
115Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Air
Con
ditio
ning
Flexible DuctingRealcoldStock No.
Diameter (mm) Length (m) Price$ Excl. GST
Nude
ACDCT0369 150 3
ACDCT0411 150 6
ACDCT0377 200 3
ACDCT0412 200 6
ACDCT0413 250 6
ACDCT0414 300 6
ACDCT0416 350 6
Insulated
ACDCT0088 150 3
ACDCT0399 150 6
ACDCT0089 200 3
ACDCT0343 200 6
ACDCT0400 250 3
ACDCT0344 250 6
ACDCT0401 300 3
ACDCT0402 300 6
ACDCT0403 350 3
ACDCT0404 350 6
ACDCT0405 400 3
ACDCT0406 400 6
Note: 450 - 600 mm Diameters are available by special order
Ducting
• Fully complies to AS4254 & AS4508 & AS1530 Pt3 and NZ Bldg Code• DUCT CORE: Aluminium foil laminated onto polyester film, permanently bonded onto a corrosion resistant coated,
spring steel wire helix• DUCT SLEEVE: Fire retardant 75 μm black low density polyethylene and UV stabilised• DUCT INSULATION: AS4508 Polyester R0.6 nominal 250 grams per mtr/sq 40 mm thick• TEMPERATURE RANGE: Maximum: +80˚C Minimum: -10˚C• COLOUR: Silver with black sleeve
Note: No glued/adhesive duct should be installed in a compressed or ovalised state for fear of long term failure
Nude
Insulated
AIR CONDITIONINGDUCTING
116Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Air
Con
ditio
ning
“Y” Piece - PolyRealcoldStock No.
Metric Size (mm) Price$ Excl. GST
Poly Nude - Non Insulated
ACDCT1233 150-150-150
ACDCT0379 200-150-150
ACDCT0471 250-200-200
ACDCT0717 300-250-250
ACDCT0718 350-300-300
ACDCT0813 400-350-300
Other sizes are available upon request.
Reducers - PolyRealcoldStock No.
Metric Size (mm) Price$ Excl. GST
Poly Nude - Non Insulated
ACDCT0486 200-150
ACDCT0487 250-200
ACDCT0488 300-250
ACDCT0489 350-300
ACDCT0490 400-350
Other sizes are available upon request.
• Manufactured from HDPE
• U.V. stabilised• Heavy duty,
robust• Smooth internal
lines• No sharp edges• Positive lock
duct tabs
Duct Joiners - GalvRealcoldStock No.
Metric Size (mm) Price$ Excl. GST
ACDCT0723 150
ACDCT0724 200
ACDCT0725 250
ACDCT0726 300
ACDCT0770 350
ACDCT0771 400
ACDCT0772 450
Other sizes are available upon request.
AIR CONDITIONINGDUCTING
117Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Air
Con
ditio
ning
Fixed Blade Diffuser - Face OnlyRealcoldStock No.
Neck Adapter Size (mm) Price$ Excl. GST
ACDCT1022 225 x 225
ACDCT1019 300 x 300
ACDCT1023 360 x 360
• Manufactured from high impact polystyrene, resistant to scratching and fading• Minimises problems associated with cold bridging in high humidity areas• Quick fixing clips, no tools required• Adjustable airflow patterns• Poly neck adapters and side entry cushion boxes - refer page 120
Double Deflection Grille - Wall DiffuserRealcoldStock No.
Neck Adapter Size (mm) Price$ Excl. GST
ACDCT2020 300 x 100
ACDCT2021 350 x 150
• Manufactured in high quality aluminium extrusion profiles, powder coated white• Designed with nylon brushes for efficient, smooth operation• Deflection blades are adjustable individually• Standard 20mm blade spacing• Suits poly boots ACDCT0714, ACDCT0715 - refer page 119
One Piece 4-Way DiffuserRealcoldStock No.
Neck Adapter Size (mm) Price$ Excl. GST
ACDCT2007 225 x 225
ACDCT2008 300 x 300
ACDCT2009 360 x 360
• One piece pressed aluminium, powder coated white• Removable core, no joints, smooth airflow • Poly neck adapters and side entry cushion boxes - refer page 120
AIR CONDITIONINGDUCTING GRILLES
118Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Air
Con
ditio
ning
One Piece Plaque DiffuserRealcoldStock No.
Neck Adapter Size (mm) Price$ Excl. GST
ACDCT2012 225 x 225
ACDCT1516 300 x 300
ACDCT2014 360 x 360
• One piece pressed aluminium, powder coated white• Removable core, no joints, smooth airflow• Poly neck adapters and side entry cushion boxes, page 120• 595 x 595mm “lay in” T-rail diffuser
Cone Ceiling DiffuserRealcoldStock No.
Neck Adapter Size (mm) Price$ Excl. GST
ACDCT1472 150
ACDCT1473 200
ACDCT1474 250
ACDCT1475 300
• Manufactured from ABS plastic• Spring loaded fixing clips• Resistant to scratching and fading• Positive lock duct tabs• Adjustable screw in centre cone to ensure balanced airflow
Uni Jet Centre Ceiling DiffuserRealcoldStock No.
Neck Adapter Size (mm) Price$ Excl. GST
ACDCT0500 150
ACDCT0501 200
ACDCT0098 250
• Manufactured from V Zero fire rated ABS plastic AS/NZ 1530 pt 3• Spring loaded fixing clips• Adjustable ‘set and forget’ damper blade• Comes with damper blade adjustment tool• Resistant to scratching and fading• Positive lock duct tabs
AIR CONDITIONINGDUCTING GRILLES
119Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Air
Con
ditio
ning
Boots - FloorRealcoldStock No.
Metric Size (mm) Price$ Excl. GST
Poly Insulated
ACDCT0714 300 x 100-150
ACDCT0715 350 x 150-200
• Manufactured from high density polyethylene• U.V. stabilized• Robust, heavy duty• Smooth internal lines • Complete with collar and damper• Positive lock duct tabs, nail holes pre punched
Eggcrate Grille - With Filter (ERHFG)RealcoldStock No.
Neck Adapter Size (mm) Price$ Excl. GST
ACDCT0962 300 x 300
ACDCT1257 360 x 360
*ACDCT0966 550 x 550
*595 x 595 mm “lay in” T-rail grille
• Manufactured in high quality aluminium extrusion profiles• Hinged removable filters• Flush face finish• Powder coated white• Filter media G2 rated• Poly neck adapters see page 120
AIR CONDITIONINGDUCTING GRILLES
Wall / Ceiling Grille with Duct SpigotRealcoldStock No.
Metric Size (mm) Colour Price$ Excl. GST
Fixed Louvre
ACDCT0063 150 White
ACDCT0340 200 White
Standard grille with some weather protection. Removable insert for ease of installation & cleaning.
120Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Air
Con
ditio
ning
Neck Adapter - PolyRealcoldStock No.
Metric Size (mm) Price$ Excl. GST
RealcoldStock No.
Price$ Excl. GST
No Damper With Damper
ACDCT0681 225 x 225-150 —
ACDCT0545 225 x 225-200 —
ACDCT0497 300 x 300-250 ACDCT0498
ACDCT0509 300 x 300-300 ACDCT0499
ACDCT0547 360 x 360 x 250 —
ACDCT0549 360 x 360 x 300 —
ACDCT0553 360 x 360 x 450 —
ACDCT0555 360 x 360 x 400 —
To convert 250 mm to 200 mm spigots use ACDCT0965 see below poly neck adapters to suit Univents, CD 2000 and some aluminium diffusers.
Stepped SpigotRealcoldStock No.
Metric Size (mm) Price$ Excl. GST
No Damper
ACDCT1409 550 x 550/400/450
Convert 250 mm SpigotsRealcoldStock No.
Metric Size (mm) Price$ Excl. GST
ACDCT1142 250-150
ACDCT0965 250-200
• Poly Adapter “Snaps-On” to plastic diffusers, no tools or fixing required• Manufactured from high impact polystyrene, positive lock duct tabs
Cushion Side Entry Box - PolyRealcoldStock No.
Metric Size (mm) Price$ Excl. GST
Poly Insulated
ACDCT1003 225 x 225 - 200 diameter
ACDCT1006 300 x 300 - 200 diameter
ACDCT0972 300 x 300 - 250 diameter
• Manufactured from HDPE, fits poly and aluminium diffusers
left: no Damper right: with Damper
AIR CONDITIONINGDUCTING NECK ADAPTERS
121Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Air
Con
ditio
ning
High Performance Axial In-Line FansRealcoldStock No.
Metric Size (mm)
Performance dBA 3m* Max. Pressure (Pa)
Price$ Excl. GST
ACFAN0085 150 89 l/s, 320 m3/hr 46 135
* dBA @ 3 metres - sound pressure based on the high speed for each fan
• Quality ball bearing motor. Continuously rated motor.• Integral mounting. High performance axial fan
Mixed Flow In-Line FansRealcoldStock No.
Metric Size (mm)
Model Max. Airflow (l/s)
Max. Pressure (Pa)
dBA 3m* Price$ Excl. GST
ACFAN1006 150 MF150S156 360
47117 320
ACFAN1007 200 MF200S
253 300
48228 225
200 150
* dBA @ 3 metres - sound pressure based on the high speed for each fan
• Designed for applications that require high air flows with relative low noise• High quality ball bearing, long life motors, continuously rated and warranted for a minimum of 30,000 hours or 4 years• Can be easily installed in series to increase pressure• 2 speed fan settings for 150 mm model and 3 speed fan settings for the 200mm model• Brackets are supplied with the fan for ease of installation• Fan assembly can be easily removed from rigid ducting installations for ease of cleaning and maintenance. • Double Insulation - no earth required• Other sizes available upon request
AIR CONDITIONINGIN-LINE FANS
Fan Dimensions (mm)Model A B* C D E F G
MF150S 147 209 360 130 115 195 55
MF200S 197 244 354 142 140 230 50
*Measured with junction box on side (junction box height of 35 mm)
122Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Air
Con
ditio
ning
Technical SpecificationModel Order
CodeSize (mm) RPM Wattage Max.
Airflow (l/s)
Max. Pressure (Pa)
Lp dBA 3m*
kg IP Rating Max. Operating Temp °C
MF150S FAN1006 1502700 70 560 360
47 3.2 44 452000 60 420 320
MF200S FAN1007 200
2700 85 910 300
48 4.5 44 452350 60 820 225
2000 45 720 150
* dBA @ 3 metres - sound pressure based on the high speed for each fan
Sound Power Levels (high speed)Model Sound Power Levels LW (dBA) - Octave band centre frequency in Hz LwA dBA
125 250 500 1000 2000 4000 8000
MF150S 58 66 65 63 62 54 46 67.5
MF200S 65 69 64 63 62 60 48 69
AIR CONDITIONINGIN-LINE FANS - TECHNICAL DATA
Mixed Flow In-Line Fans - Performance Curve
123Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Air
Con
ditio
ning
Axial In-Line Performance Curves
High Performance Axial In-Line Fans ACFAN0085 Technical Data
Hyper150 High Performance Axial FanNoise Level dBA @ 3m 46Frequency Hz 50/60Power Input W 38Current A 0.38Speed RPM 2650Voltage V 240Weight kg 1.3Max. Ambient Temp °C 70
Axial In-Line Fan Dimensions
AIR CONDITIONINGIN-LINE FANS - TECHNICAL DATA
124Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Air
Con
ditio
ning
AIR CONDITIONINGEVAPORATIVE COOLING
Evaporative Cooler Selection Formula - Based on 90% saturation efficiencyRoom Volume x 25, all changes = m³/hr
Convert to Litre / Sec (m³/hr / 3.6)
Air-Changes Selection Table for Various Ambient Air Properties
Ambient °CRelative Humidity Percentage %
20% 30% 40% 50% 60% 70%
25 13.5 15.5 17.0 19.0 20.5 22.0
30 16.5 19.0 21.0 23.0 25.0 26.5
35 20.2 22.5 25.0 27.5 29.5 31.0
40 23.0 26.0 29.0 31.5 33.5 36.0
45 27.0 30.0 32.5 35.5 38.0 40.5
Evaporative Air Conditioning - Cool Breeze
Cool Breeze evaporative air conditioning is the natural healthy way to cool your office, factory, show-room, warehouse or home.
Unlike refrigerated air conditioning systems where air is dried, chilled and re-circulated, a Cool Breeze evaporative system uses the natural element of water to cool the air. The air is always fresh because stale air is continually expelled through open doors and windows.
This technology, although enjoying enormous growth, is still largely underutilized and unknown in many parts of the world. EAC can provide cooling and ventilation with minimum energy consumption and without the use of ozone depleting chemicals such as CFC’s and HFC’s.
The principle of EAC is simple and commonly found in nature. For example, warm air passing over the ocean is cooled through the evaporative process before it reaches the mainland. This occurs because the warm air causes the water to evaporate and as the water evaporates, it absorbs the heat from the warm air, thereby cooling it.
In a modern evaporative air conditioner water is pumped from the base of the cooler onto the top of the pads. The important function of the fan is to draw air from the outside through the moisture laden filter pads, and then force the cooled air into the ductwork to be distributed into the building. It is therefore important to have some openings, such as doors or windows, sufficiently open to allow all the air in the building to escape.
Evaporative Cooler Selection Formula
Room Volume x 25 Air Changes = m3/hr
Convert to Litre/Sec
m3/hr ÷ 3600 x 1000 = Litre/Sec
For Example:
Room 24m x 12m x 4.5 m = 1296m3
1296m3/hr x 25 air changes = 32,400m3/hr
32,400 ÷ 3600 x 1000 = 9000 litres/sec
The table below (based on 90% humidity) shows the temperature drop that can be achieved at differ-ent levels of humidity. Note that the level of humidity will affect the temperature drop possible, however in the last 5 years many technological advancements have greatly improved the cooling capacity and performance of evaporative coolers.
125Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Air
Con
ditio
ning
AIR CONDITIONINGEVAPORATIVE COOLING
Down Discharge ModelRealcoldStock No.
Cool Breeze Model #
kW Equivalent
Motor Cldek Pad Nominal Air Flow
Price$ Excl. GSTWatts mm
AC8000 D095 7 600 75 2,000l/s
AC8001 D125 9 600 75 2,800l/s
AC8002 D160 11 750 100 3,500l/s
AC8003 D195 13 1,000 100 4,200l/s
AC8004 D230 15 1,000 100 5,000l/s
AC8005 D255 17 1,000 100 5,400l/s
Down Discharge Model - Twin FanRealcoldStock No.
Cool Breeze Model #
kW Equivalent
Motor Cldek Pad Nominal Air Flow
Price$ Excl. GSTWatts mm
AC8007 D500 34 1,000 x 2 100 10,000l/s
Side & Top Discharge ModelRealcoldStock No.
Cool Breeze Model #
kW Equivalent
Motor Cldek Pad Nominal Air Flow
Price$ Excl. GSTWatts mm
AC8008 FT195 13 1,000 100 4,200l/s
AC8009 FT230 15 1,000 100 5,000l/s
AC8010 FT255 17 1,000 100 5,400l/s
AC8011 S100 8 600 758 2,200l/s
AC8012 S240 15 1,000 100 5,100l/s
Mobile Side Discharge ModelRealcoldStock No.
Cool Breeze Model #
kW Equivalent
Motor Cldek Pad Nominal Air Flow
Price$ Excl. GSTWatts mm
AC8013 M240 17 1,000 100 5,400l/s
Quietflo Plenums & Adapters - AGP SeriesRealcoldStock No.
Cool Breeze Model #
Description Price$ Excl. GST
AC8220 QFPA2 AGP2 4 way (D095 ~ D160)
AC8221 QFPA3 AGP3 4 way (D195 ~ D255)
AC8224 QFPA4 AGP4 6 way (FD500)
AC8222 QFA2 Dropper Adapter to suit QFPA2
AC8223 QFA3 Dropper Adapter to suit QFPA3
AC8225 QFA4 Dropper Adapter to suit QFPA4
Adapter 2
AGP2
AGP3
AGP4
QM Wall Control
CPR Wall Control
126Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Syst
em C
ompo
nent
s
Accumulators - Suction LineRealcoldStock No.
DescriptionkW Cap at Evap. Temp. -6°C
Price$ Excl. GST
Size Connection R22 R404A / R507C
F0804 1/2" ODS Vertical 4.6 4.8
F0805 5/8" ODS Vertical 6.9 7.2
F0806 3/4" ODS Vertical 9.2 9.6
F0807 7/8" ODS Vertical 16.7 17.5
F0809 1 1/8" ODS Vertical 27.0 28.3
F0811 1 3/8" ODS Vertical 43.1 45.2
F0813 1 5/8" ODS Vertical 65.3 68.4
F0121 2 1/8” LCY 1817 S/MMS 125 130
F0125 3 1/8” LCY 5025S 288 300
* These accumulators should not be used below -18°C without supplementary heating to ensure oil return - see information on Heater Elements below.
Accumulator
SYSTEM COMPONENTSACCUMULATORS
Factors for Determining CapacityEvap. Temp. -18°C -30°CFactor .68 .41Note: To find kW capacity for the other evaporator temperatures, multiply factor X rating listed at -6°C
Selection of a suction line accumulator should be made on the basis of the following capabilities:• The accumulator should have an adequate liquid holding capacity - normally not less than 50% of the system charge. • The accumulator should perform efficiently without excessive pressure drop to the system.• The accumulator should return oil at the proper rate and under a range of conditions of load.
• The selection of the suction line accumulator should not be based on line size, but on its ability to perform well within the limits described above. Consequently the suction line accumulator will not necessarily have the same connection size as the compressor suction line.
Heater Elements To Suit Accumulators
Elements must be used when operating under -18°C. The element adds heat to oil separators in order to prevent migration of refrigerant to the vessel during the off cycles of the compressor. Heater elements also add heat to suction line accumulators, to keep the oil warm, permitting oil return to the compressor on low temperature applications. Refer to page 127.
127Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Syst
em C
ompo
nent
s
Oil SeparatorsRealcoldStock No.
Model ODS Nominal Capacity kW * Dimen. (mm)H x D
Price$ Excl. GST
R22 R404A
-5°C -25°C -5°C -25°C
F0869 S-5581 3⁄8" 4.7 3.3 4.7 3.3 210x102
F0070 NS-1004 1⁄2" 6.7 6.0 6.7 6.0 260x102
F0072 NS-1005 5⁄8” 18.6 17 18 15.8 362x102
F0074 NS-1007 7⁄8” 27.4 25.7 28.2 25 450x102
F0076 NS-3009 1 1⁄8” 35.6 33.5 36.8 32.7 533x102
F0078 NS-3011 1 3⁄8” 46 42.8 46.5 41 540x102
F0080 NS-3013 1 5⁄8” 61.6 58 63.6 57.5 472x153
F0882 S-5694 2 1⁄8” 101.7 93.8 103.6 92.5 486x158
Henry Helical Oil Separators/Oil ReservoirsRealcoldStock No.
Model ODS Nominal Capacity kW * Dimen. (mm)H x D
Price$ Excl. GST
R22 R404A
-5°C -25°C -5°C -25°C
F0347 S-5392 1 5⁄8" 63.3 56.3 66.8 52.7 890x150
F0348 S-5394 2 1⁄8" 105.5 87.9 109.0 84.4 890x150
F0351 S-5302 2 1⁄8" 123.1 137.1 109.0 144.2 640x200
F0352 S-5303 2 5⁄8" 281.3 249.7 291.9 225.0 750x250
• All capacities shown are based on 37.8°C condensing temperature with an 18.3°C suction gas temperature.• Dimensions are Height x Diameter in millimetres.
Replacement FloatRealcoldStock No.
Description Price$ Excl. GST
F0330 A1900-30 Float Assembly suits S-5200 and S1900 series
F0331 2-023-001 Float Valve Gasket
AC & R Heater ElementsHeat elements add heat to oil separators to prevent migration of refrigerant to the vessel during off cycles of the compressor. Also suitable for AC & R accumulators.
RealcoldStock No.
Description Price$ Excl. GST
F0084S-9111 4” diameter 220 volt 25 WattSuits S-5520, S-5180 series oil separators
SYSTEM COMPONENTSOIL CONTROL SYSTEMS
128Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Syst
em C
ompo
nent
s
Trax Oil Control SystemsRealcoldStock No.
Description Price$ Excl. GST
F0092 TRAX TR3201 Oil Level Control System
Oil Reservoir And AccessoriesRealcoldStock No.
Description Price$ Excl. GST
F0052Henry S-9130 Adjustable Oil Level Regulator with 3/8” MF SAE equalisation connection 90 psi max. differential. Replaces S9191, S9131, S9134, S9133, S9190, & S9193
F0053A C & R S-9108 Oil Reservoir (4 US gallon capacity) 15 litres The oil reservoir is the holding vessel for stand-by oil necessary for the operation of the oil control system.
F0055 A C & R S-9109 Oil Reservoir (2 US gallon capacity) 7.5 litres 3/8 Flare Rotalock Valve
F0057
Henry S-9104 Reservoir Pressure Valve 3/8 Flare ConnectionsThis valve will maintain a 5lb. positive pressure differential at the oil reservoir over the crankcase pressure ensuring an adequate oil supply to the oil level regulator.
F0062
Henry S-9104H High Pressure Check Reservoir ValveSome parallel compressor systems have a satellite compressor which maintains a higher suction pressure than the other compressor system. The S-9104H provides a 20 lb positive pressure in the oil reservoir for this application.
F0058
Henry S-9241 Oil Level Regulator Shut-Off Valve 3/8 MF x 3/8 FF Swivel Connection S-9106-vertical mountThis valve allows each oil level regulator to be isolated if service is required on a compressor. Vertical model. For equalization lines on S-9130 regulator.
F0060 Henry 3/033/212 Sight Glass Adapter 3 bolt 1.7/8 to suit Copeland 8R Series, Frascold W Series
F0059
A C & R S-9105 Oil Line Strainer 3/8 MF Flare- 100 Mesh 11 sq in.This strainer protects the oil level regulator by removing foreign matter. The strainers mesh screen provides adequate straining with low pressure drop.
F0066*Henry S-4005 POE Oil Filter Drier 3/8” MF. 6 micron filtrationRemoves foreign material from the oil as it passes through the filter.
F0067Henry S-9106H Horizontal Shut-Off Valve3/8” MF x 3/8” FF, swivel connection. Horizontal model for use where space is limited.
Oil FiltersRealcoldStock No.
Description Price$ Excl. GST
SP2600 Sporlan OF-303 Oil Filter 3/8" Flare
SP2601 Sporlan OF-303-BP Oil Filter W/Bypass 3/8" Flare
F0052
F0059
F0067
F0058
F0057/62
F0053/5
F0066
SYSTEM COMPONENTSOIL CONTROL SYSTEMS
129Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Syst
em C
ompo
nent
s
Vertical ReceiversRealcoldStock No.
Model Pump Down Capacity Kg @ 80%
Connections PRV Required Yes/No
Price$ Excl. GSTSweat Rotalock Valves
SuppliedYes/No
R22 R134a R404AInlet Outlet Inlet Outlet
F0261 RLVCY15 1.4 1.4 1.3 1⁄4” 1⁄4” 3⁄4” 3⁄4” N Y
F0264 RLVCY30 2.8 2.8 2.4 3⁄8” 3⁄8” 3⁄4” 3⁄4” N Y
F0280 RLVCY40 3.8 3.8 3.3 3⁄8” 3⁄8” 3⁄4” 3⁄4” N Y
F0284 RLVCY60 5.5 5.5 4.9 1⁄2” 1⁄2” 1” 1” N Y
F0292 RLVCY120M 11.0 11.0 9.8 5⁄8” 5⁄8” 1 1⁄4” 1 1⁄4” N Y
Receivers have fittings for Rotalock valves. Also the same connection allows for a solder connection as above. Gaskets are 3/4”: H1103; 1”: H1104. Mounting is by single M10 stud (F0261-F0280) or M12 (F0284).
Pressure Relief Devices
The requirements for the installation of pressure valves into pressure vessels are proscribed within AS/NZS1677.2.1998 and its amendments.
Viz;
1. Vessels of less than 300L internal gross volume:
• Vessels containing more than 1.5kg of Group B2 refrigerants: or
• 1.0 Kg of Group A3 refrigerants must be fitted with 1 or more mechanical pressure relief devices.
2. Vessels of greater than 300 L internal gross volume:
• Pressure vessels which may contain liquid refrigerant and which may be shut off from other parts of the refrigeration system shall be protected by means of two pressure relief valves.
• If the vessel is on the high pressure side of the system, the pressure relief valves shall be controlled by a changeover device.
SYSTEM COMPONENTSRECEIVERS VERTICAL LIQUID
130Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Syst
em C
ompo
nent
s
Sporlan Driers - FlareRealcoldStock No.
Model Size Cu In Price$ Excl. GST
Liquid Line Driers - Sporlan
SP3001 CATCH-ALL 032 1/4" MF 3
SP3002 CATCH-ALL 052 1/4" MF 5
SP3003 CATCH-ALL 082 1/4" MF 8
SP3004 CATCH-ALL 162 1/4" MF 16
SP3008 CATCH-ALL 053 3/8" MF 5
SP3009 CATCH-ALL 083 3/8" MF 8
SP3011 CATCH-ALL C163 3/8" MF 16
SP3012 CATCH-ALL 303 3/8" MF 30
SP3015 CATCH-ALL 084 1/2” MF 8
SP3017 CATCH-ALL 164 1/2" MF 16
SP3018 CATCH-ALL 304 1/2" MF 30
SP3022 CATCH-ALL 165 5/8" MF 16
SP3023 CATCH-ALL 305 5/8" MF 30
SP3025 CATCH-ALL 415 5/8" MF 41
Sporlan Driers - SweatRealcoldStock No.
Model Size Cu In Price$ Excl. GST
Liquid Line Driers - Sporlan
SP3071 CATCH-ALL 032S 1/4" SWEAT 3
SP3072 CATCH-ALL 052S 1/4" SWEAT 5
SP3073 CATCH-ALL C082S 1/4" SWEAT 8
SP3078 CATCH-ALL C053S 3/8" SWEAT 5
SP3079 CATCH-ALL C083S 3/8" SWEAT 8
SP3081 CATCH-ALL C163S 3/8" SWEAT 16
SP3085 CATCH-ALL C084S 1/2" SWEAT 8
SP3087 CATCH-ALL C164S 1/2" SWEAT 16
SP3092 CATCH-ALL C165S 5/8" SWEAT 16
Sky Driers - FlareRealcoldStock No.
Model Size Cu In Price$ Excl. GST
Liquid Line Driers - Sky
H0125 FL 306 3/4" MF 30
SYSTEM COMPONENTS DRIERS
131Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Syst
em C
ompo
nent
s
SF Suction Line FiltersThe Sporlan SF Suction Line Filter protects the compressor from dirt. It is designed with an optional relief feature that opens if the filter plugs. It also has a full flow design for low pressure drop. It is suitable for use with all brazing alloys and maximum corrosion resistance.
RealcoldStock No.
Description Price$ Excl. GST
SP3155 Sporlan Suction Filter SF-285-T 5/8" SW
SP3156 Sporlan Suction Filter SF-286-T 3/4" SW
SP3157 Sporlan Suction Filter SF-287-T 7/8" SW
SP3159 Sporlan Suction Filter SF-289-T 1.1/8" SW
SP3161 Sporlan Suction Filter SF-4811-T 1.3/8" SW
SP3163 Sporlan Suction Filter SF-4813-T 1.5/8" SW
Suction Line Filter DriersThe Suction Line Filter Drier has been specifically designed for system clean-up after a burn out or any time system cleanliness is questionable. High acid and water absorption. For use with HCFCs, HFCs, and lubricants that go with them. Not recommended for permanent use. Once the suction line filter drier has completed its clean-up procedure it should be replaced with a suction line filter.
RealcoldStock No.
Model Description Filter Area Sq. In.
Volume Cu. In.
Price$ Excl. GST
Burn-Out Driers
H0306 Mueller A17224 1/2" SW 26 16
H0308 Mueller A17227 5/8" SW 26 16
H0311 Mueller A17225 1/2" MF 26 16
H0312 Mueller A17226 5/8" MF 26 16
H0313 Mueller A17228 3/4" SW 26 16
H0314 Mueller A17229 7/8" SW 26 16
H0315 Mueller A17230 1.1/8" SW 26 16
H0316 Mueller A17231 1.1/8" SW 52 30
SYSTEM COMPONENTSSUCTION FILTERS
Mueller Driers - SweatRealcoldStock No.
Model Size Cu In Price$ Excl. GST
Liquid Line Driers - Mueller
H0130 SD 417 7/8" SWEAT 41
Directional Liquid Line Driers (directional/ bi-directional)RealcoldStock No.
Model Description Price$ Excl. GST
H0247 MA Line D111 12 gram XH9 Service Drier 1/4” ODS inlet - capillary connection outlet with separate charging port
H0250 MA Line D109 10 gram XH9 Service Drier 1/4” ODS inlet - bi-directional
H0256 MA Line D114 30 gram XH9 Service Drier 5/16” in 1/4” outlet
Note: Driers with XH9 desiccant are suitable for all refrigerants including blends and R134a
132Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Syst
em C
ompo
nent
s
Reversible Heat Pump Driers
RealcoldStock No.
Sporlan Code Description Price$ Excl. GST
SP3240 HPC-103 Heat Pump Drier 3/8" MF
SP3241 HPC-104 Heat Pump Drier 1/2" MF
SP3250 HPC-103S Heat Pump Drier 3/8" OD
SP3251 HPC-104S Heat Pump Drier 1/2" OD
SP3261 HPC-165SHH Heat Pump Drier 5/8" OD
Refillable Shells - Suction LineRealcoldStock No.
Model Size Core Max. RatingkW Med Temp
Max. Rating kW Low Temp
Price$ Excl. GST
SP3462 Sporlan RSF-489T 1 1/8" ODS 1 core 25.7 9.9
SP3463 Sporlan RSF-4811T 1 3/8" ODS 1 core 31.3 12
SP3464 Sporlan RSF-4813T 1 5/8" ODS 1 core 33.8 12.7
SP3465 Sporlan RSF-4817T 2 1/8" ODS 1 core 95.0 59.8
SP3466 Sporlan RSF-4821T 2 5/8" ODS 1 core 123.0 80.9
SP3471 Sporlan RSF-9621T 2 5/8" ODS 2 core 141.0 91.4
SP3472 Sporlan RSF-9625T 3 1/8" ODS 2 core 193.0 123.0
Sporlan RSF Suction Driers: kW are based on R404A
SYSTEM COMPONENTSDRIERS
SP3240
Refillable Shells - Liquid LineRealcoldStock No.
Model Size Core Max. RatingkW Med Temp
Max. Rating kW Low Temp
Price$ Excl. GST
Refillable Shells - Liquid Line - Carly
SP3405 Sporlan C-485G 5/8" ODS 1 Core 35.2 26.4
SP3407 Sporlan C-487G 7/8" ODS 1 Core 52.8 35.2
SP3416 Sporlan C-967G 7/8" ODS 2 Core 87.2 52.8
SP3408 Sporlan C-489G 1 1/8" ODS 1 Core 52.8 35.2
SP3417 Sporlan C-969G 1 1/8" ODS2 Core 1/4" FPT connection
101.9 87.9
SP3419 Sporlan C-9611G 1 3/8" ODS 2 Core 123 87
SP3113 Sporlan C-14411G 1 3/8" ODS3 Core 1/4" FPT connection
137.1 123
SP3420 Sporlan C-9613G 1 5/8" ODS 2 Core 120 106
SP3429 Sporlan C-14413G 1 5/8" ODS 3 Core 176 123
SP3416
133Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Syst
em C
ompo
nent
s
Briquettes To Suit Refillable Shells - InterchangeableRealcoldStock No.
Model Description Price$ Excl. GST
SP3702 Sporlan RC-4864 Catch-All core standard.
SP3703 Sporlan RC-4864-HH Catch-All activated charcoal core.
SP3704 Sporlan RCW-48 Catch-All High Water capacity core.
SP3706 Sporlan RC-10098 Catch-All Core
Sectional View Drier Core
SYSTEM COMPONENTSDRIERS
Suction Line Filter Elements To Suit Above ShellsRealcoldStock No.
Model Description Price$ Excl. GST
SP3710 Sporlan RPE-48-BD Pleated Suction Line Filter Element
GasketsRealcoldStock No.
Model Description Price$ Excl. GST
SP3725 1291-001 Gaskets AS-1704
SP3710
SP3725
134Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Syst
em C
ompo
nent
s
Liquid/Moisture Indicating - Sporlan See-All Sight GlassesRealcoldStock No.
Description Price$ Excl. GST
SP2700 1⁄4" MF
SP2703 3⁄8" MF
SP2710 1⁄2" MF
SP2717 5⁄8" MF
SP2701 1⁄4" MF FF
SP2704 3⁄8" MF FF
SP2711 1⁄2" MF FF
SP2709 5⁄8” MF x SN
SP2702 1⁄4" ODS
SP2705 3⁄8" ODS
SP2712 1⁄2" ODS
SP2718 5⁄8" ODS
SP2722 7⁄8" ODS
SP2723 1 1⁄8" ODS
SP2724 1 3⁄8" ODS
SP2728 2 1⁄8” ODS
SYSTEM COMPONENTSSIGHT GLASSES
Sight Glasses For Soldering On To PipeRealcoldStock No.
Description Price$ Excl. GST
H0770 1 3⁄8" SW
H0771 1 5⁄8" SW
H0772 2 1⁄8" SW
H0773 2 5⁄8" SW
* Note: Listed sight glasses are suitable for all refrigerants except ammonia refrigeration systems.
135Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Valv
es
Rotalock ValvesRealcoldStock No.
Model Description Price$ Excl. GST
H1006 1/4" Valve Flare Horizontal 3/4" R/L
H1007 3/8" Valve Sweat ID Horizontal 1" R/L
H1009 3/8" Valve Flare Horizontal 3/4" R/L
H1014 1/2" Valve Sweat ID Horizontal 1" R/L
H1017 5/8" Valve Sweat ID Horizontal 1" R/L
H1031 3/4" Valve Sweat ID Horizontal 1 1/4" R/L
H1036 7/8" Valve Sweat ID Horizontal 1 1/4" R/L
H1042 1 1/8" Valve Sweat ID Horizontal 1 3/4" R/L
H1045 1 3/8" Valve Sweat ID Horizontal 1 3/4" R/L
H1074 1 1/4" Rotalock Spud less process port
H1080 1 3/4" Rotalock Spud less process port
H1103 3/4" Teflon Fibre Seal
H1104 1" Teflon Fibre Seal
H1105 1 1/4" Teflon Fibre Seal
H1106 1 3/4" Teflon Fibre Seal
Note: Valves have top gauge connection
VALVESROTALOCK VALVES
136Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Valv
es
VALVESSHUT-OFF & RELIEF VALVES
Mueller Hand Shut-Off Valves (packless line valves)Mueller valves have full size openings for maximum flow with minimum restriction. The maximum working pres-sure is 500 psi with flow in direction of the arrow, and 350 psi with flow against the arrow. Working temperature range is -40°C to +90°C. All valves diaphragm type.
RealcoldStock No.
Model Description Price$ Excl. GST
H0820 Mueller 1/4" ODS Two way straight through
H0822 Mueller 1/2" ODS Two way straight through
H0841 Mueller 1/4" MF Two way straight through
H0842 Mueller 3/8" MF Two way straight through
H0843 Mueller 1/2" MF Two way straight through
H0844 Mueller 5/8" MF Two way straight through
Three Way Hand Shut-Off ValvesRealcoldStock No.
Description Maximum Working Pressure
Price$ Excl. GST
G0580 Henry 925 Brass 1/2" FPT Dual shut off valve 675 psi
G0582 Mueller Brass 1/2" FPT Dual shut off valve 700 psi
• Body - Forged Brass. Seat Discs - Steel• Working Temperature Range: -40°C to +149°C
Mueller Pressure Relief ValvesValves listed are constructed and stamped with the ASME UV symbol in accordance with the requirements of the ASME and are approved by Maritime Transport - a Division of the New Zealand Ministry of Transport. The set point of the relief valve must not exceed the safe working pressure (SWP) stamped on an approved receiver.
RealcoldStock No.
Model Size Connections Pressure Settings
Capacity Ratings
Price$ Excl. GST
Inlet Outlet PSI kPa Lbs Air/Min
G0543 Mueller A-15508-AH 1/8" MPT Atmosphere 400 3413 7.1
G0544 Mueller A-15508-AG 1/8" MPT Atmosphere 350 2578 6.3
G0545 Mueller A-15508-AE 1/8" MPT Atmosphere 300 2069 5.4
G0546 Mueller A-15509-AE 1/4" MPT Atmosphere 300 2069 5.4
G0547 Mueller A-15509-AG 1/4" MPT Atmosphere 350 2413 6.3
G0548 Mueller A-15509-AH 1/4" MPT Atmosphere 400 2578 7.1
G0559 Mueller A-15504-AE 1/2" MPT 5/8" MF 300 2069 25.4
G0565 Mueller A-15504-AG 1/2" MPT 5/8" MF 350 2413 29.5
G0567 Mueller A-15504-AH 1/2" MPT 5/8" MF 400 2578 33.5
Note: The above are National Pipe Threads 9.27
Atmosphere
Straight Through
137Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Valv
es
Saginomiya 4-Way Reversing ValveRealcoldStock No.
Model Description Capacity Refrigerator Pipe Sizes Coil Voltage Price$ Excl. GSTR22 R410A Discharge Suction &
Coils
G1100CHV-0201 STF-0201"G"
Reversing Valve C/W Coil
2.6 3R22 R407C R410A
9.52 (3/8") 12.7 (1/2") YES 230V AC 50Hz
G1112 STF-0214"G"Reversing Valve C/W Coil
3R22 R407C R410A
12.7 (1/2") 15.88 (5/8") YES 230V AC
50Hz
G1114 STF-0408"G"Reversing Valve C/W Coil
6R22 R407C R410A
12.7 (1/2") 19.05 (3/4") YES 230V AC
50Hz
ACSG0169 SHF-20A-46Reversing Valve without Coil
5.7 6.7R22 R407C R410A
12.7 (1/2") 19.05 (3/4") NO —
CHV Coils for Reversing Valves
G1105 CHV-01AI501A1
CHV Coil suits CHV/STF 101~2011
— — — — — — 230V AC 50Hz
VALVESCHECK VALVES
Check Valves - Refrigerants HFC & HCFCThese valves offer minimum restriction to flow and provide a positive seal against reverse flow. They will operate in any position.
RealcoldStock No.
Model Description Price$ Excl. GST
G0501 Mueller 1/4" Male Flare Max. working pressure 500 psi Max. Temperature +93°C
G0503 Mueller 3/8" Male Flare “
G0505 Mueller 1/2" Male Flare “
G0507 Mueller 5/8" Male Flare “
G0490 Mueller 1/4" ODS Extended Ends “
G0491 Mueller 3/8" ODS Extended Ends “
G0492 Mueller 1/2" ODS Extended Ends “
G0493 Mueller 5/8" ODS Extended Ends “
G0509 Mueller 7/8" ODS B34235 Max. working pressure 450 psi Max. Temperature +149°C
G0510 Mueller 1.1/8" ODS B34236 “
G0511 Mueller 1.3/8" ODS B34237 “
G0512 Mueller 1.5/8" ODS B34238 “
G0514 Mueller 2.1/8" ODS B34239 “
138Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Valv
es
Mueller Ball Valves (two way)Mueller ball valves may be used on high and low pressure refrigerant lines for either gas or liquid service. Suit-able for HCFC, HFC refrigerants, and all refrigerant oils. The ball seals are carbon filled teflon. This permits higher sealing force than with virgin teflon, yet gives extended sealing life with the greater strength of the filled material. Maximum working pressure is 700 psi. Maximum temperature range -40°C to +149°C.
RealcoldStock No.
Model Description Price$ Excl. GST
H0868 Mueller 3/8" ODS Full Port
H0869 Mueller 1/2" ODS Full Port
H0870 Mueller 5/8" ODS Full Port
H0871 Mueller 7/8" ODS Full Port
H0872 Mueller 1 1/8" ODS Full Port
H0873 Mueller 1 3/8" ODS Full Port
H0875 Mueller 1 5/8" ODS Full Port
H0876 Mueller 2 1/8" ODS Full Port
H0877 Mueller 2 5/8" ODS Reduced Port
H0878 Mueller 3 1/8" ODS Reduced Port
Mueller Liquid Receiver ValvesMaximum working pressure 500 psi. Maximum temperature rating 149°C. MP are NPT (National Pipe Thread).
RealcoldStock No.
Model Description Price$ Excl. GST
H0951 Mueller A - 11031 1/4" MF x 1/4” MP
H0952 Mueller A - 13613 1/4” MF x 3/8” MP
H0953 Mueller A - 11030 3/8” MF x 1/4” MP
H0954 Mueller A - 13503 3/8” MF x 3/8” MP
H0955 Mueller A - 11042 1/2” MF x 3/8” MP
H0956 Mueller A - 13220 1/2” MF x 1/2” MP
H0958 Mueller A - 13183 5/8” MF x 1/2” MP
VALVESBALL & LIQUID RECEIVER VALVES
Check Valve - GasketsRealcoldStock No.
Model Description Price$ Excl. GST
G0517 Mueller 1.3/8" - 1.5/8" Gasket Suit Mueller Check Valves
G0518 Mueller 2.1/8" Gasket Suit Mueller Check Valves
Note: Mueller B342 series check valves are 4-bolt flange types for easy disassembly when brazing and can be installed vertically or horizontally. Full port construction.
139Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Valv
es
Sporlan Q-Series Thermostatic Expansion Valves3/8” x 1/2” - 90º connections, flare or sweat. All OD models are forged inlet models.
RealcoldStock No.
Model Description Price$ Excl. GST
SP0001 SQ-ODF Q Valve Body OD Internally Equalised External Strainer
SP0002 SQE-ODF Q Valve Body OD Externally Equalised External Strainer
SP0003 Q-SAE Q Valve Body MF Internally Equalised External Strainer
SP0004 QE-SAE Q Valve Body MF Externally Equalised External Strainer
SP0071 SBQ-ODF BQ Valve Body OD Internally Equalised
SP0072 SBQE-ODF BQ Valve Body OD Externally Equalised
SP0073 BQ-SAE BQ Valve Body MF Internally Equalised
SP0074 BQE-SAE BQ Valve Body MF Externally Equalised
Sporlan OrificesRealcoldStock No.
Model Description Nominal Capacity kW Price$ Excl. GSTR404A R22 R134a
SP0010 QC-0 Orifice No. 0 Red 0.59 1.17 0.59
SP0011 QC-1 Orifice No. 1 Yellow 0.88 2.64 0.88
SP0012 QC-2 Orifice No. 2 Green 1.76 3.52 1.76
SP0013 QC-3 Orifice No. 3 Blue 3.52 5.28 3.52
SP0014 QC-4 Orifice No. 4 Pink 5.28 8.79 5.28
SP0015 QC-5 Orifice No. 5 Black 7.03 12.3 7.03
SP0016 QC-6 Orifice No. 6 White 10.6 17.6 8.79
SP0080 AAA BQ Orifice Red 0.44-0.70 0.44-1.16 0.44-0.70
SP0081 AA BQ Orifice Yellow 0.88-1.16 1.76-2.34 0.88-1.16
SP0082 A BQ Orifice Blue 1.76-3.52 2.64-5.30 1.76-3.52
SP0083 B BQ Orifice Pink 4.40-7.03 6.16-10.60 4.40-6.16
SP0084 C BQ Orifice White 7.90-10.60 11.4-19.30 7.03-10.60
SQ-ODF
SQE-ODF
Q-SAE
QE-SAE
VALVESQ-SERIES THERMOSTATIC
140Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Valv
es
Sporlan Thermostatic ElementsRealcoldStock No.
Model Description Price$ Excl. GST
SP0020 KT-43-VC-5' TX Element R22 Commercial -25/+10°C
SP0030 KT-43-JC-5' TX Element R134a Commercial -25/+10°C
SP0040 KT-43-SC-5' TX Element R404A Commercial -25/+10°C
SP0041 KT-43-SZ-5' TX Element R404A LT -18/-40°C
SP0042 KT-43-SZP-5' TX Element R404A LT MOP -18/-40°C
SP0044 KT43-VZ-5' TX Element R22 LT- Q Series -18/-40°C
Sporlan AccessoriesRealcoldStock No.
Model Description Price$ Excl. GST
SP0060 791-001 Cartridge O-Ring
SP0061 184-002 Allen Wrench
SP0062 QVT-1 Q Valve Tool
SP0063 1538-000 Inlet Strainer for all Q Body 3/8” Flare Valves
SP0064 3427-000 Inlet Strainer for all Q Body 3/8” ODF Valves
VALVESELEMENTS & ACCESSORIES
SP0030
141Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Valv
es
Sporlan J8 Thermostatic Expansion ValvesSuitable for all refrigerants except Ammonia and High Pressure Carbon Dioxide. Drop-in replacement for Danfoss TX Valves. Has interchangeable orifice to control capacity. Orifices also suitable for use with Danfoss T2 and TE2 Valves
Refrigerant RealcoldStock No.
Model Inlet Outlet Equa-lised
MOP Bar / °C Evap / Temp Range
Price$ Excl. GST
134A
SP5001 TX 134A J8S-JW BODY 3/8" Flare 1/2" Solder No — -40 to +15°C
SP5002 TX 134A J8ES-JW BODY 3/8" Flare 1/2" Solder Yes — -40 to +15°C
SP5015 TX 134A J8F-JW BODY 3/8" Flare 1/2" Flare No — -40 to +15°C
SP5016 TX 134A J8EF-JW BODY 3/8" Flare 1/2" Flare Yes — -40 to +15°C
SP5030 TX 134A J8S-JX60 BODY 3/8" Flare 1/2" Solder No 4.1 Bar +17°C -40 to +15°C
SP5031 TX 134A J8ES-JX60 BODY 3/8" Flare 1/2" Solder Yes 4.1 Bar +17°C -40 to +15°C
SP5038 TX 134A J8F-JX60 BODY 3/8" Flare 1/2" Flare No 4.1 Bar +17°C -40 to +15°C
SP5039 TX 134A J8EF-JX60 BODY 3/8" Flare 1/2" Flare Yes 4.1 Bar +17°C -40 to +15°C
404A
SP5005 TX 404A J8S-SW BODY 3/8" Flare 1/2" Solder No — -40 to +10°C
SP5006 TX 404A J8ES-SW BODY 3/8" Flare 1/2" Solder Yes — -40 to +10°C
SP5017 TX 404A J8F-SW BODY 3/8" Flare 1/2" Flare No — -40 to +15°C
SP5018 TX 404A J8EF-SW BODY 3/8" Flare 1/2" Flare Yes — -40 to +15°C
SP5034 TX 404A J8S-SX110 BODY 3/8" Flare 1/2" Solder No 7.6 Bar +12°C -40 to +10°C
SP5035 TX 404A J8ES-SX110 BODY 3/8" Flare 1/2" Solder Yes 7.6 Bar +12°C -40 to +10°C
SP5036 TX 404A J8S-SX35 BODY 3/8" Flare 1/2" Solder No 2.4 Bar -17°C -40 to -18°C
SP5037 TX 404A J8ES-SX35 BODY 3/8" Flare 1/2" Solder Yes 2.4 Bar -17°C -40 to -18°C
SP5040 TX 404A J8F-SX110 BODY 3/8" Flare 1/2" Flare No 7.6 Bar +12°C -40 to +10°C
SP5041 TX 404A J8EF-SX110 BDY 3/8" Flare 1/2" Flare Yes 7.6 Bar +12°C -40 to +10°C
SP5042 TX 404A J8F-SX35 BODY 3/8" Flare 1/2" Flare No 2.4 Bar -17°C -40 to -18°C
SP5043 TX 404A J8EF-SX35 BODY 3/8" Flare 1/2" Flare Yes 2.4 Bar -17°C -40 to -18°C
R22
SP5003 TX R22 J8S-VW BODY 3/8" Flare 1/2" Solder No — -40 to +15°C
SP5004 TX R22 J8ES-VW BODY 3/8" Flare 1/2" Solder Yes — -40 to +15°C
SP5019 TX R22 J8F-VW BODY 3/8" Flare 1/2" Flare No — -40 to +15°C
SP5020 TX R22 J8EF-VW BODY 3/8" Flare 1/2" Flare Yes — -40 to +15°C
SP5032 TX R22 J8S-VX100 BODY 3/8" Flare 1/2" Solder No 6.9 Bar +17°C -40 to +15°C
SP5033 TX R22 J8ES-VX100 BODY 3/8" Flare 1/2" Solder Yes 6.9 Bar +17°C -40 to +15°C
SP5044 TX R22 J8F-VX100 BODY 3/8" Flare 1/2" Flare No 6.9 Bar +17°C -40 to +15°C
SP5045 TX R22 J8EF-VX100 BODY 3/8" Flare 1/2" Flare Yes 6.9 Bar +17°C -40 to +15°C
Valve Features Advantages and Benefits
• US Manufacture and Quality• Copper Capillary 5-Times better Conductivity than Stainless Steel• Plasma Welded rather than Laser Welded• New design, Long-Life Diaphragm• Copper Connections
VALVES J8 THERMOSTATIC
142Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Valv
es
VALVES J8 THERMOSTATIC
Sporlan J8 Thermostatic Expansion Valves OrificeSuitable for all refrigerants except Ammonia and High Pressure Carbon Dioxide. Drop-in replacement for Danfoss TX Valves. Has interchangeable orifice to control capacity. Orifices also suitable for use with Danfoss T2 and TE2 Valves
RealcoldStock No.
Model R134a R22 R404A R507C Price$ Excl. GST
SP5007 Orifice J8C - 0X 0.44 0.66 0.45 0.57
SP5008 Orifice J8C - 00 0.77 1.2 0.79 1.0
SP5009 Orifice J8C - 01 1.7 2.3 1.6 2.3
SP5010 Orifice J8C - 02 3.1 4.1 2.8 3.7
SP5011 Orifice J8C - 03 4.6 6.1 4.2 5.5
SP5012 Orifice J8C - 04 6.9 9.2 6.3 8.3
SP5013 Orifice J8C - 05 8.7 11.7 8.0 10.5
SP5014 Orifice J8C - 06 10.4 14.0 9.6 15.0
Nominal capacities at +5°C evaporating temperatures, +32°C condensing temperatures.
Cross Reference Table - J8 / T2 / TIRefrigerant Int / Ext Inlet x Outlet
Inch: 3/8” x 1/2” (inch)Parker Item Number
J8 Code MOP °C"
T2/TE2 Part No
MOP °C"
TI/TIE Part No
MOP °C"
Valve Configuration Sporlan Danfoss Alco
R134
a
Ext flare x flare 600000 J8EF-JW no 068Z3348 no TIE-MW no
Ext flare x flare 600001 J8EF-JX60 +17°C 068Z3349 +15°C — —
Ext flare x solder 600014 J8ES-JW no 068Z3385 no TISE-MW no
Ext flare x solder 600015 J8ES-JX60 +17°C 068Z3389 +15°C — —
Int flare x flare 600021 J8F-JW no 068Z3346 no TI-MW no
Int flare x flare 600022 J8F-JX60 +17°C 068Z3347 +15°C — —
Int flare x solder 600035 J8S-JW no 068Z3383 no TI-SMW no
Int flare x solder 600036 J8S-JX60 +17°C 068Z3387 +15°C — —
R407
C
Ext flare x flare 600002 J8EF-NW no 068Z3501 no — —
Ext flare x flare 600003 J8EF-NX100 +17°C 068Z3517 +15°C — —
Ext flare x solder 600016 J8ES-NW no 068Z3446 no — —
Ext flare x solder 600017 J8ES-NX100 +17°C 068Z3447 +15°C — —
Int flare x flare 600023 J8F-NW no 068Z3496 no — —
Int flare x flare 600024 J8F-NX100 +17°C 068Z3516 +15°C — —
Int flare x solder 600037 J8S-NW no — no — —
Int flare x solder 600038 J8S-NX100 +17°C 068Z3329 +15°C — —
This information is intended only as a guide. For further information or selection assistance, please contact your local branch. Realcold accepts no liability for the information provided and any selection is the reponsibility of the purchaser / installer.
143Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Valv
es
Cross Reference Table - J8 / T2 / TIRefrigerant Int / Ext Inlet x Outlet
Inch: 3/8” x 1/2” (inch)Parker Item Number
J8 Code MOP °C"
T2/TE2 Part No
MOP °C"
TI/TIE Part No
MOP °C"
Valve Configuration Sporlan Danfoss Alco
R404
A
Ext flare x flare 600004 J8EF-SW no 068Z3403 no TIE-SW no
Ext flare x flare 600005 J8EF-SX110 +12°C 068Z3405 +15°C — —
Ext flare x flare 600006 J8EF-SX35 -17°C 068Z3409 068Z3411
-10°C -20°C — —
Ext flare x solder 600018 J8ES-SW no 068Z3415 no TIS-SW no
Ext flare x solder 600019 J8ES-SX110 +12°C 068Z3417 +15°C — —
Ext flare x solder 600020 J8ES-SX35 -17°C 068Z3430 068Z3421
-10°C -20°C — —
Int flare x flare 600025 J8F-SW no 068Z3400 no TI-SW no
Int flare x flare 600026 J8F-SX110 +12°C 068Z3402 +15°C — —
Int flare x flare 600027 J8F-SX35 -17°C 068Z3408 068Z3410
-10°C -20°C — —
Int flare x solder 600039 J8S-SW no 068Z3414 no TIS-SW no
Int flare x solder 600040 J8S-SX110 +12°C 068Z3416 +15°C — —
Int flare x solder 600041 J8S-SX35 -17°C 068Z3429 068Z3420
-10°C -20°C — —
R22
Int flare x solder 600061 J8S-VX100 +17°C 068Z3287 +15°C — —
Int flare x solder 600059 J8S-VW no 068Z3281 no TIS-HW no
Ext flare x flare 600058 J8EF-VX100 +17°C 068Z3211 +15°C — —
Ext flare x solder 600057 J8ES-VX100 +17°C 068Z3290 +15°C — —
Int flare x flare 600054 J8F-VX100 +17°C 068Z3208 +15°C — —
Int flare x flare 600053 J8F-VW no 068Z3206 no TI-HW no
Ext flare x solder 600052 J8ES-VW no 068Z3284 no TISE-HW no
Ext flare x flare 600051 J8EF-VW no 068Z3209 no TIE-HW no
All
— J8 orifice & filter - 0X 506032 J8C-0X — 068-2002 — T1-00X —
— J8 orifice & filter - 00 506033 J8C-00 — 068-2003 — T1-000 —
— J8 orifice & filter - 01 506034 J8C-01 — 068-2010 — T1-001 —
— J8 orifice & filter - 02 506035 J8C-02 — 068-2015 — T1-002 —
— J8 orifice & filter - 03 506036 J8C-03 — 068-2006 — T1-003 —
— J8 orifice & filter - 04 506037 J8C-04 — 068-2007 — T1-004 —
— J8 orifice & filter - 05 506038 J8C-05 — 068-2008 — T1-005 —
— J8 orifice & filter - 06 506039 J8C-06 — 068-2009 — T1-006 —
This information is intended only as a guide. For further information or selection assistance, please contact your local branch. Realcold accepts no liability for the information provided and any selection is the reponsibility of the purchaser / installer.
VALVESREFERENCE TABLE
144Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Valv
es
Sporlan TX Valve Replacement HeadsRealcoldStock No.
Description Price$ Excl. GST
SP1202 KIT KT33-VCP100 - For R22, Commercial, MOP100. Suits P, Large O and H Series Valves
SP1220 KT83-VCP100 - For R22, Commercial, MOP100. Suits C, Small O and S Series Valves
SP1221 KT83-VC - For R22, Commercial. Suits C, Small O and S Series Valves
SP1224 KT83-SC - For R404A, Commercial. Suits C, Small O and S Series Valves
SP1225 KT83-SZ - For R404A, Low Temp. Suits C, Small O and S Series Valves
SP1234 KT83-RZP - For R507, Low Temp, MOP35. Suits C, Small O and S Series Valves
C Charge: +10/-23°C Commercial Applications.CP100 Charge: Air Conditioning MOP ChargeZ Charge: -18/-40°C Low Temperature ZP Charge: -18/-40°C M.O.P. MOP valves are normally used to prevent hunting or compressor overload, or to limit flow at start-up under lightly loaded conditions. Can be used in place of a crankcase pressure regulator (in certain applications).BP Balanced Port: Balanced port valves counteract effects of pressure drop (loss of valve efficiency) working well down to 25% rated capacity. All other valves operate to 35% of rated capacity.
Sporlan S and O-Series ValvesRefrigerant Realcold
Stock No.Model Connection Charge Capacity Price
$ Excl. GSTTons kW
R22
SP0734 SVE-5 1/2" x 7/8" OD C 5 17.5
SP0737 SVE-8 5/8" x 7/8" OD C 8 28.1
SP0741 SVE-15 7/8" x 1.1/8" OD C 15 52.7
SP0756 OVE-20 7/8" x 1.3/8" OD BP C 20 70.3
SP0757 OVE-30 1.1/8” x 1.3/8” OD BP C 30 105
SP0758 OVE-40 1.1/8" x 1.3/8" OD BP C 40 140
SP0761 OVE-40-CP100 1.1/8” x 1.3/8” OD BP CP100 40 140
SP0764 OVE-55-CP100 1.1/8” x 1.3/8” OD BP CP100 55 193
R404
A
SP0774 SSE-4-C 1/2" x 7/8" OD C 4 13.7
SP0777 SSE-6-C 5/8" x 7/8" OD C 6 20.5
SP0780 SSE-7-C 5/8" x 7/8" OD C 7 23.9
SP0786 SSE-10-C 5/8" x 7/8" OD C 10 34.1
SP0792 OSE-12 7/8" x 1.3/8" OD C 12 40.9
SP0803 SSE-4-Z 1/2" x 7/8" OD Z 4 13.7
SP0806 SSE-4-ZP 1/2" x 7/8" OD ZP 4 13.7
SP0809 SSE-6-Z 5/8" x 7/8" OD Z 6 20.5
SP0812 SSE-6-ZP 5/8" x 7/8" OD ZP 6 20.5
SP0814 SSE-7-Z 5/8" x 7/8" OD Z 7 23.9
SP0817 SSE-7-ZP 5/8" x 7/8" OD ZP 7 23.9
SP0820 SSE-10-Z 7/8" x 1.1/8" OD Z 10 34.1
SP0823 SSE-10-ZP 7/8" x 1.1/8" OD ZP 10 34.1
SP0841 OSE-21-Z 1.1/8" x 1.3/8" OD BP Z 21 74
SP0842 OSE-21-ZP 1.1/8" x 1.3/8" OD BP ZP 21 74
SP0845 OSE-30-Z 1.1/8" x 1.3/8" OD BP Z 30 105
SP0846 OSE-30-ZP 1.1/8" x 1.3/8" OD BP ZP 30 105
SP0849 OSE-35-ZP 1.1/8" x 1.3/8" OD BP ZP 35 120
Type S-Series
Type O-Series
VALVESS & O-SERIES
145Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Valv
es
Sporlan Solenoid Valves (less coil)RealcoldStock No.
Model Coil Description Price$ Excl. GST
SP1405 E5S120 MKC1 Solenoid Valve 1/4" OD
SP1411 B6F1 MKC1 Solenoid Valve 3/8" MF
SP1414 E6S130 MKC1 Solenoid Valve 3/8" OD
SP1415 ME6S130 MKC1 Solenoid Valve 3/8" OD Manual Lift Version
SP1427 B10F2 MKC2 Solenoid Valve 1/2" MF
SP1430 E9S240 MKC2 Solenoid Valve 1/2" OD
SP1431 ME9S240 MKC2 Solenoid Valve 1/2" OD Manual Lift Version
SP1450 E14S250 MKC2 Solenoid Valve 5/8" OD
SP1452 ME14S250 MKC2 Solenoid Valve 5/8" OD Manual Lift Version
SP1462 E19S270 MKC2 Solenoid Valve 7/8" OD
SP1464 ME19S270 MKC2 Solenoid Valve 7/8" OD Manual Lift Version
SP1472 E25S290 MKC2 Solenoid Valve 1.1/8" OD
SP1474 ME25S290 MKC2 Solenoid Valve 1.1/8" OD Manual Lift Version
SP1827 ME35S1110 MKC1/OMKC1
Solenoid Valve 1.3/8" OD Manual Lift Version
SP1829 ME42S2130 MKC2 Solenoid Valve 1.5/8” OD Manual Lift Version
SP1800 180 180 Solenoid Pilot Control 1/4” MF
• The E5, E6 E9 and E14 are compact solenoids with Pilot Operated construction. They may be mounted Horizontal, Side On or in a Vertical Line.
• The E19 and E25 are Pilot Operated solenoids. They may be mounted Horizontal, Side On, or in a Vertical Line. • All E series valves feature extended connections, for installation without disassembly, using low silver
content brazing alloy.
Sporlan Solenoid CoilsRealcoldStock No.
Model Description Price$ Excl. GST
SP1900 MKC1 Solenoid Coil 240V 50HZ
SP1901 MKC1E Solenoid Coil 240V 50HZ
SP1905 MKC2 Solenoid Coil 240V 50HZ
SP1906 MKC2E Solenoid Coil 240V 50HZ
Many more models and variations are available - just ask your Realcold representative for advice.
E9S240, E6S130, E5S120
E25S290, E19S270
MKC-1, MKC-2
MKC1E
VALVESSOLENOID VALVES
146Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Valv
es
Parker Hannifin SpA Solenoid Valves (complete with coils)Suitable for all HFC and HCFC refrigerants, in liquid, suction, or hot gas. Fluid temperature range -30°C to +105°C. All valves come complete with 240 volt ±10%, 50/60 Hz coil, wired, plus bracket.
RealcoldStock No.
Model OrificeSize (mm)
MinimumPressure (bar)
Max Diff.Pressure (MOPD) bar
Kv (m³/hr)
Price$ Excl. GST
G0250 Parker 1/4” MF DA 3 0.0 21 0.27
G0252 Parker 1/4” ODS DA 3 0.0 21 0.27
G0254 Parker 3/8” MF DA 3 0.0 21 0.27
G0255 Parker 3/8” MF PO 8 0.1 21 1.40
G0260 Parker 3/8” ODS PO 8 0.1 21 1.40
G0265 Parker 1/2” MF PO 10 0.1 21 1.75
G0270 Parker 1/2” ODS PO 10 0.1 21 1.75
G0275 Parker 5/8” MF PO 15 0.1 21 2.65
G0280 Parker 5/8” ODS PO 15 0.1 21 2.65
G0285 Parker 3/4” ODS PO 18 0.1 21 3.15
G0290 Parker 7/8” ODS PO 18 0.1 21 3.50
G0295 Parker 1 1/8” ODS PO 18 0.1 21 3.50
G0298 Parker 1 3/8” ODS PO 25.4 0.14 21 8.80
All valves come complete with 240 volt ±10%, 50/60 Hz coil, wired.
Abbreviations: DA = Direct Acting. PO = Pilot Operated
Minimum Pressure: This is the lowest differential pressure required for the correct operation of the solenoid valve
Maximum Pressure: This refers to the highest differential operating pressure
(MOPD): With the lowest tolerance applied on the nominal voltage-coil
Kv = Flow Factor: Volume (m³/hr) flowing through the valve at a pressure drop of 1 bar across the valve at a temperature of 20°C
Parker Hannifin SpA Solenoid Valve Spares (replacement Solenoid coils)RealcoldStock No.
Model Description Price$ Excl. GST
G0302 YE09 240 Volt 50/60 Hz 9 Watt
G0312 ZB09 240 Volt 50/60 Hz
9 Watt(DIN 40050 = IP 65 Coil)
G0301 JB14 240 Volt 50/60 Hz 14 Watt
G0303 YB12 24 Volt DC Coil 12 Watt
G0307 YB19 240 Volt 50/60 Hz 11 Watt
G0310 YB09 24 Volt 50/60 Hz 9 Watt
G0313 For ZB09 Faston Connector for (G0312) (Coil DIN = IP 65)
G0251 170511 Spare Solenoid Bracket
VALVESSPA SOLENOID VALVES
147Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Valv
es
Crankcase Pressure RegulatorsRealcoldStock No.
Model Pressure Range Size Price$ Excl. GST
SP2003 CRO-6-0/60 0-60 psig 1/2” ODF
SP2004 CRO-6-0/60 0-60 psig 5/8” ODF
SP2009 CRO-6-30/110 30-110 psig 5/8” ODF
SP2010 CRO-6-30/110 30-110 psig 7/8” ODF
SP2012 CRO-10-0/60 0-60 psig 7/8” ODF
SP2013 CRO-10-0/60 0-60 psig 1 1/8” ODF
SP2014 CRO-10-0/60 0-60 psig 1 3/8” ODF
SP2015 CRO-10-30/110 30-110 psig 7/8” ODF
SP2016 CRO-10-30/110 30-110 psig 1 1/8” ODF
SP2017 CRO-10-30/110 30-110 psig 1 3/8” ODF
CRO-6
CRO-10
VALVESPRESSURE REGULATORS
Evaporator Pressure RegulatorsRealcoldStock No.
Model Pressure Range Size Price$ Excl. GST
SP2100 ORIT-6 0 - 50 psig 1/2” MF
SP2103 ORIT-6 0 - 50 psig 5/8” ODF
SP2104 ORIT-6 0 - 50 psig 7/8” ODF
SP2107 ORIT-6 30-100 psig 5/8” ODF
SP2109 ORIT-6 30-100 psig 7/8” ODF
SP2110 ORIT-6 30-100 psig 1.1/8” ODF
SP2114 ORIT-10 30-100 psig 7/8” ODF
SP2115 ORIT-10 30-100 psig 1.1/8” ODF
SP2116 ORIT-10 30-100 psig 1.3/8” ODF
SP2130 ORIT-10 0-50 psig 7/8” ODF
SP2132 ORIT-10 0-50 psig 1.1/8” ODF
SP2134 ORIT-10 0-50 psig 1.3/8” ODF
• Refer to the Realcold Technical Department for capacity ratings.• Many more models and variations are available.
ORIT-10
ORIT-6
Evaporator Pressure Regulators (externally pilot operated)RealcoldStock No.
Model Pressure Range Size Price$ Excl. GST
SP2160 (S) ORIT-12 0-100 psig 1.1/8” OD
SP2162 (S) ORIT-15 0-100 psig 1.3/8” OD
SP2164 (S) ORIT-20 0-100 psig 1.5/8” OD
• (S) ORIT-PI’s are Evaporator Pressure Regulating Valves Piloted Internally with an Electric Shut-off option, using a MKC1 Coil - Supplied separately.
(S) ORIT
148Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Valv
es
Sporlan CDS ValvesThe CDS family of valves provide precise temperature or pressure control of DX evaporators. Proper temperature is obtained by regulating refrigerant flow in the evaporator in response to signals generated by an electronic controller/sensor combination. Designed for low pressure drop, the CDS valves provide energy savings and are able to shorten pulldown time after defrost to one half or less than mechanical EPR valves. The extremely stable control helps compressor life by minimising changes in suction pressure that lead to short or excessive cycling.
RealcoldStock No.
Model Description Price$ Excl. GST
SP2240 CDS9 5/8” Electronic evaporator pressure regulator
SP2241 CDS9 7/8” Electronic evaporator pressure regulator
SP2242 CDS9 1 1/8” Electronic evaporator pressure regulator
SP2242A CDS9 1 3/8” Electronic evaporator pressure regulator
SP2244 CDS17 1 3/8” Electronic evaporator pressure regulator
SP2245 CDS17 1 5/8” Electronic evaporator pressure regulator
SP2246 CDS17 2 1/8” Electronic evaporator pressure regulator
• Please contact one of our technical staff to assist you with selecting a suitable EPR valve for your application.• n Nominal ratings at -100C Evaporating temperature / 0.4bar pressure drop• n Other valves sizes available on request - Please contact Realcold for details.
Sporlan Hot Gas Bypass ValvesThe TCB interface/controller allows all Sporlan step motors to be modulated in response to an externally generated signal. The IB and TCB accept a 4-20 milliamp, or 0-10 volt DC inputs and stroke the valve
proportionately to that signal. The TCB and IB allow use of the CDS or SDR valves with an existing DDC system or other generic temperature controller for hot gas bypass, evaporator temperature, or reclaim applications. When the TCB is purchased with optional set point potentiometer and sensor, the TCB becomes a stand alone single point temperature control for the CDS or SDR valves. The sensor is installed in the air stream or affixed to the pipe
containing the liquid to be controlled. The potentiometer is set to the temperature desired, and the TCB will modulate the valve to maintain tight temperature control. The TCB can be configured to “close on rise” or “open on rise” and requires only an external 24 volt AC 40 VA power source.
RealcoldStock No.
Model Description Price$ Excl. GST
SP2360 ADRSE-2 1/2” ODF Hot Gas Bypass Valve 0-80 psig
CDS-17
CDS-9
VALVESCDS VALVES
(S) ORIT-PI
Evaporator Pressure Regulators (internally pilot operated)RealcoldStock No.
Model Pressure Range Size Price$ Excl. GST
SP2204 (S) ORIT-PI-27S 0-100 psig 7/8” OD
SP2206 (S) ORIT-PI-29S 0-100 psig 1.1/8" OD
SP2214 (S) ORIT-PI-39S 0-100 psig 1.1/8" OD
SP2216 (S) ORIT-PI-311S 0-100 psig 1.3/8" OD
SP2224 (S) ORIT-PI-513S 0-100 psig 1.5/8" OD
SP2226 (S) ORIT-PI-517S 0-100 psig 2.1/8" OD
• (S) ORIT-PI’s are Evaporator Pressure Regulating Valves Piloted Internally with an Electric Shut-off option, using a MKC1 Coil - Supplied separately.
149Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Valv
es
Sporlan CO2 Product RangeSporlan’s growing line of products for CO2 is setting new standards for robust design and advanced technology. Contact your Realcold branch for more information.
RealcoldStock No.
Model Family MRP/MOPD Application Price$ Excl. GST
psig bar
Electric Expansion Valves
SER 700 48Subcritical DX, Secondary
SEI 620 43
Evaporator Control and Secondary Refrigerant Valves
SEI 620 43
Subcritical DX, SecondarySER 700 48
SDR 620 43
CDS 700 48
Controllers, Accessories
ECM - CO2 — —
Subcritical DX, Secondary
CO2 - Superheat — —
Kelvin CO2 — —
Temperature Sensor
-40 - 210°F
-40 - 100°C
Pressure Transducer 500 34
Sightglass, Filter Drier
See-All® Sightglass 650 45
Subcritical DX, SecondaryCatch-All® Filter Drier 650 45
Solenoi Valves
E3 700/450 48/31
Subcritical DX, Secondary
E5S130-HP 700/450 48/31
E6S130-HP 700/450 48/31
E9S240-HP 700/450 48/31
E9S250-HP 700/450 48/31
E14S250-HP 700/450 48/31
E10S250-HP 700/450 48/31
VALVESCO2 PRODUCT RANGE
150Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Tube
& F
ittin
gs
Pre-Insulated Copper TubeRealcoldStock No.
Model Description Wall Thickness Swp Price$ Excl. GSTImperial Metric Metric kPA Psi
TOYO Pair Coil - 20 metre Coil
AC0002 TD-2320-8 1/4" x 3/8" 6.35 x 9.53 0.80 0.80 9835 x 6329 1427 x 919
AC0003 TD-2420 1/4" x 1/2" 6.35 x 12.7 0.80 0.80 9835 x 4665 1427 x 677
AC0004 TD-2520 1/4" x 5/8" 6.35 x 15.88 0.80 1.00 9835 x 4665 1427 x 677
AC0005 TD-3520 3/8" x 5/8" 9.53 x 15.88 0.80 1.00 6329 x 4665 919 x 677
AC0006 TD-3630Z 3/8" x 3/4" 9.53 x 19.05 0.80 1.20 6329 x 4665 919 x 677
TOYO Single Coil - 20 metre Coil
AC0011 SD-320 3/8" 9.53 0.80 6329 919
AC0012 SD-420 1/2" 12.7 0.80 4665 677
AC0014 SD-620Z 3/4" 19.05 1.20 4665 677
REALCOLD Pair Coil - 20 metre Coil
AC0056 OPS-2320 1/4" x 3/8" 6.35 x 9.53 0.80 0.80 9835 x 6329 1427 x 919
AC0057 OPS-2420 1/4" x 1/2" 6.35 x 12.7 0.80 0.80 9835 x 4665 1427 x 677
AC0058 OPS-2520 1/4" x 5/8" 6.35 x 15.88 0.80 1.00 9835 x 4665 1427 x 677
AC0059 OPS-3520 3/8" x 5/8" 9.53 x 15.88 0.80 1.00 6329 x 4665 919 x 677
Notes: 1) Values of SWP are derived from the formula from ANSI B31 Standard Code for Pressure Piping.
2) The value of Maximum Stress (S) used in the calculation is 150°F (65.6°C) and is for copper in its annealed condition.
For pipe temperatures higher than 150°F (65.6°C), please contact your local Realcold branch for assistance in the selection of appropriate tube for your requirement.
Drainage HoseRealcoldStock No.
Model Description Price$ Excl. GST
AC0745 DRS Drainage Socket - Drain Y Connector
AC0749 DRH-14N Drain Hose 14 mm x 50m Coil Non Insulated
AC0755 WRH-16 Drain Hose 16 mm x 50m Coil Lined
AC0817 1DH-20JH Joint for 20 mm Drainage Hose
Drainage hose is made of Linear Low Density Polyethylene - light weight, high mechanical strength and better UV resistance (5000hr durable in weather testing). Joint
The Tube Insulation is of double-layered structure made up of cross-linked, foamed, closed cell polyethylene.
The covering is of embossed polyethylene, free of defects, and does not crease when bent. Seamless extrusion is used to ensure close contact with the copper tube, and to enhance the dew-proofing properties. Heat resistance is up to 120º C. and the insulation is manufactured to JIS A9511 P2 Standard.
The Copper Tube is soft annealed and is to JIS H3300 C1220T Standard. R410A compatible.
TUBE & FITTINGSCOPPER TUBE
151Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Tube
& F
ittin
gs
Soft Drawn CopperRealcoldStock No.
Outside Diameter Wall Thickness SWP WT per 15m Length Kg
Price$ Excl. GSTInches mm Inches mm PSI kPa
15 metre coils
H0031 1/4 6.35 0.032 0.8128 1711 11796 1.89
H0032 3/16 4.76 0.032 0.8128 2371 16349 1.35
H0033 5/16 7.94 0.032 0.8128 1338 9226 2.43
18 metre coils
H0034 3/8 9.5 0.032 0.81 1094 7546 3.56
H0035 1/2 12.5 0.032 0.81 807 5561 4.87
H0036 5/8 15.8 0.040 1.02 813 5602 7.66
H0037 3/4 19 0.040 1.02 671 4628 8.33
H0038 7/8 22.2 0.045 1.143 642 4425 12.17
Refrigeration grade dehydrated and nitrogen purged copper tube manufactured in accordance with AS1571.
Capillary Service PacksThese service packs offer a complete selection for large commercial and air conditioning units to the smallest domestic refrigeration requirements. Selection Data Information included in Pack.
RealcoldStock No.
Description Price$ Excl. GST
G0381 SP-1 .026" ID (0.66 mm) in 3.660 metre coils
G0382 SP-2 .0315" ID (0.80 mm) in 3.660 metre coils
G0383 SP-3 .0355" ID (0.90 mm) in 3.660 metre coils
G0384 SP-4 .0435" ID (1.10 mm) in 4.270 metre coils
G0385 SP-5 .051" ID (1.30 mm) in 4.270 metre coils
G0386 SP-6 .055" ID (1.40 mm) in 3.660 metre coils
G0387 SP-7 .064" ID (1.62 mm) in 3.050 metre coils
G0388 SP-8 .070" ID (1.78 mm) in 3.660 metre coils
G0389 SP-9 .075" ID (1.90 mm) in 2.750 metre coils
G0390 SP-10 .080" ID (2.04 mm) in 3.050 metre coils
G0391 SP-11 .088" ID (2.24 mm) in 3.660 metre coils
TUBE & FITTINGSSOFT DRAWN COPPER
152Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Tube
& F
ittin
gs
TUBE & FITTINGSHARD DRAWN COPPER
Hard Drawn Copper (5 metre lengths)RealcoldStock No.
Outside Diameter Wall Thickness SWP WT per 5m Length Kg
Price$ Excl. GST
Inches mm Inches mm PSI kPa
H0058 3/8 9.53 0.030 0.76 869 5992 0.94
H0059 1/2 12.70 0.035 0.89 757 5220 1.47
H0060 5/8 15.88 0.040 1.02 691 4764 2.12
H0061 3/4 19.05 0.042 1.07 600 4137 2.69
H0062 7/8 22.23 0.045 1.14 545 3758 3.38
H0063 1.1/8 28.58 0.050 1.27 470 3241 4.87
H0064 1.3/8 34.93 0.055 1.40 422 2910 6.57
H0065 1.5/8 41.28 0.060 1.52 387 2668 8.48
H0075 2.1/8 53.98 0.070 1.78 345 2379 13.02
H0076 2.5/8 66.68 0.080 2.03 318 2193 18.44
H0077 3.1/8 79.38 0.090 2.29 301 2075 24.77
Refrigeration grade dehydrated and nitrogen charged: Copper tube manufactured in accordance with AS1571/ANSIB31
153Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Tube
& F
ittin
gs
Thick Walled Hard Drawn Copper (5.8 metre lengths)Refrigeration grade, dehydrated and nitrogen purged, sealed copper tube. Manufactured in accordance with AS/NZ 1571 ASTMB 280 Refrigeration Code. Manufactured in accordance with ASTM B88 - Cleaned in accordance with ASTM B280.
RealcoldStock No.
Outside Diameter Wall Thickness SWP Price$ Excl. GST
Inches mm Inches mm PSI kPa
H1719 3/4 19.05 0.046 1.18 665 4583
H1722 7/8 22.23 0.064 1.63 795 5478
H1728 1.1/8 28.58 0.072 1.83 688 4746
H1735 1.3/8 34.93 0.085 2.15 660 4553
H1742 1.5/8 41.28 0.102 2.6 677 4665
TUBE & FITTINGSHARD DRAWN COPPER
Hard Drawn Copper (5.8 metre lengths - economy range)RealcoldStock No.
Outside Diameter Wall Thickness SWP WT per 5.8m Length Kg
Price$ Excl. GSTInches mm Inches mm PSI kPa
H0058H 3/8 9.53 0.030 0.76 869 5992 1.08
H0059H 1/2 12.70 0.035 0.89 757 5220 1.71
H0060H 5/8 15.88 0.040 1.02 691 4764 2.46
H0061H 3/4 19.05 0.042 1.07 600 4137 3.12
H0062H 7/8 22.23 0.045 1.14 545 3758 3.92
H0063H 1.1/8 28.58 0.050 1.27 470 3241 5.65
H0064H 1.3/8 34.93 0.055 1.40 422 2910 7.62
H0065H 1.5/8 41.28 0.060 1.52 387 2668 9.84
H0075H 2.1/8 53.98 0.070 1.78 345 2379 15.10
H0076H 2.5/8 66.68 0.080 2.03 318 2193 21.39
H0077H 3.1/8 79.38 0.090 2.29 301 2075 28.73
Note: NZS1677 stipulates the method of calculating the maximum operating pressure for air cooled refrigeration systems to be the highest. Price fluctuations are dictated daily by the London Metal Exchange (LME).
154Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Tube
& F
ittin
gs
TUBE & FITTINGSCOPPER FITTINGS
900 Long Radius Copper ElbowRealcoldStock No.
Size (Inch) R410A Price$ Excl.
GST
J1002 1/4" x 90° lr
J1154 1/2" x 90° lr
J1155 5/8" x 90° lr
J1156 3/4" x 90° lr
J1157 7/8" x 90° lr
J1159 1.1/8" x 90° lr
J8019 1.1/8” x 90° lr
RealcoldStock No.
Size (Inch) R410A Price$ Excl.
GST
J1161 1.3/8" x 90° lr
J8020A 1.3/8" x 90° lr
J1163 1.5/8" x 90° lr
J8023A 1.5/8" x 90° lr
J1165 2.1/8” x 90° lr
J1167 2.5/8” x 90° lr
J1169 3.1/8” x 9° lr
900 Short Radius Copper ElbowRealcoldStock No.
Size (Inch) R410A Price$ Excl.
GST
J1003 3/8" x 90°
J1004 1/2" x 90°
J1005 5/8" x 90°
J1110 3/4" x 90°
J1111 7/8" x 90°
RealcoldStock No.
Size (Inch) R410A Price$ Excl.
GST
J1113 1.1/8" x 90°
J1114 1.3/8" x 90°
J1115 1.5/8" x 90°
J1116 2.1/8” x 90°
J1117 2.5/8" x 90°
J1118 3.1/8" x 90°450 Copper ElbowRealcoldStock No.
Size (Inch) R410A Price$ Excl.
GST
J0992 3/8”
J0991 1/2”
J0993 5/8"
J0994 3/4"
J0995 7/8"
J0998 1.1/8"
J8046* 1.1/8”
RealcoldStock No.
Size (Inch) R410A Price$ Excl.
GST
J0999 1.3/8"
J8049 1.3/8”
J1000 1.5/8"
J8051 1.5/8”
J1001 2.1/8"
J0988 2.5/8"
J0989 3.1/8"
Copper TeesRealcoldStock No.
Size (Inch) R410A Price$ Excl.
GST
J1133 1/4"
J1132 5/16"
J1134 3/8"
J1135 1/2"
J1136 5/8"
J1137 3/4"
J1138 7/8"
RealcoldStock No.
Size (Inch) R410A Price$ Excl.
GST
J8104 1.1/8”
J1140 1.1/8"
J1141 1.3/8"
J1142 1.5/8"
J1144 2.1/8"
J1145 2.5/8"
J1146 3.1/8"
155Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Tube
& F
ittin
gsTUBE & FITTINGS
COPPER FITTINGS
Copper Reducers (Coupling ID X ID)RealcoldStock No.
Size ID (Inch)
Size ID (Inch)
R410A Price$ Excl.
GST
J1170 3/8 1/4
J1171 1/2 1/4
J1172 1/2 3/8
J1173 5/8 3/8
J1174 5/8 1/2
J1175 3/4 3/8
J1176 3/4 1/2
J1177 3/4 5/8
J1178 7/8 1/2
J1179 7/8 5/8
J1180 7/8 3/4
J1181 1.1/8 5/8
J1182 1.1/8 3/4
J1183 1.1/8 3/4
J1184 1.1/8 7/8
RealcoldStock No.
Size ID (Inch)
Size ID (Inch)
R410A Price$ Excl.
GST
J1185 1.3/8 5/8
J1186 1.3/8 3/4
J1187 1.3/8 7/8
J1188 1.3/8 1.1/8
J1189 1.5/8 7/8
J1191 1.5/8 1.1/8
J1192 1.5/8 1.3/8
J1193 1.5/8 1.3/8
J1194 2.1/8 1.1/8
J1195 2.1/8 1.3/8
J1196 2.1/8 1.5/8
J1197 2.5/8 1.3/8
J1198 2.5/8 1.5/8
J1199 2.5/8 2.1/8
J1201 3.1/8 2.5/8
Copper Reducers (Bush OD X ID)RealcoldStock No.
Size OD (Inch)
Size ID (Inch)
R410A Price$ Excl.
GST
J1308 3/4 1/2
J1309 3/4 5/8
J1312 7/8 1/2
J1311 7/8 5/8
J1310 7/8 3/4
J8192A 1.1/8 5/8
J1312B 1.1/8 5/8
J1314 1.1/8 3/4
J8199A 1.1/8 7/8
J1313 1.1/8 7/8
J1319 1.3/8 5/8
J8204A 1.3/8 7/8
J1318 1.3/8 7/8
RealcoldStock No.
Size OD (Inch)
Size ID (Inch)
R410A Price$ Excl.
GST
J1317 1.3/8 1.1/8
J1322 1.5/8 7/8
J1321 1.5/8 1.1/8
J8217 1.5/8 1.3/8
J1320 1.5/8 1.3/8
J1326 2.1/8 1.1/8
J1325 2.1/8 1.3/8
J1324 2.1/8 1.5/8
J1330 2.5/8 1.3/8
J1332 2.5/8 1.5/8
J1329 2.5/8 2.1/8
J1331 3.1/8 2.5/8
156Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Tube
& F
ittin
gs
TUBE & FITTINGSCOPPER FITTINGS
Copper CouplingsRealcoldStock No.
Size (Inch) R410A Price$ Excl.
GST
J1203 3/8"
J1204 1/2"
J1205 5/8"
J1206 3/4"
J1207 7/8"
J1209 1.1/8"
J8133A 1.1/8"
RealcoldStock No.
Size (Inch) R410A Price$ Excl.
GST
J1211 1.3/8"
J8136 1.3/8"
J1212 1.5/8"
J8138A 1.5/8"
J1213 2.1/8"
J1214 2.5/8"
J1215 3.1/8"
Copper Return Bends 1800
RealcoldStock No.
Size (Inch) R410A Price$ Excl.
GST
J1120 3/8" x 180°
J1121 1/2" x 180°
J1122 5/8” x 180°
J1123 3/4" x 180°
RealcoldStock No.
Size (Inch) R410A Price$ Excl.
GST
J1123D 7/8" x 180°
J1125 1.1/8" x 180°
J1126 1.3/8" x 180°
J1127 1.5/8" x 180°
Copper ‘P’ TrapsRealcoldStock No.
Size (Inch) R410A Price$ Excl.
GST
J1498 5/8"
J1499 3/4"
J1500 7/8"
J1501 1.1/8"
RealcoldStock No.
Size (Inch) R410A Price$ Excl.
GST
J1502 1.3/8"
J1503 1.5/8"
J1504 2.1/8"
157Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Tube
& F
ittin
gsTUBE & FITTINGS
COPPER FITTINGS
Copper Flare BonnetsRealcoldStock No.
Size (Inch) R410A Price$ Excl.
GST
J0790 1/4” Bonnet
J0791 5/16” Bonnet
J0792 3/8” Bonnet
RealcoldStock No.
Size (Inch) R410A Price$ Excl.
GST
J0793 1/2” Bonnet
J0794 5/8” Bonnet
J0795 3/4” Bonnet
Copper Flare GasketsRealcoldStock No.
Size (Inch) R410A Price$ Excl.
GST
J0810 1/4" Gasket
J0811 5/16” Gasket
J0812 3/8" Gasket
RealcoldStock No.
Size (Inch) R410A Price$ Excl.
GST
J0813 1/2" Gasket
J0814 5/8" Gasket
J0815 3/4" Gasket
Copper End CapsRealcoldStock No.
Size (Inch) R410A Price$ Excl.
GST
J1345 5/8"
J1346 3/4"
J1347 7/8"
J1351 1.1/8"
J1353 1.3/8"
RealcoldStock No.
Size (Inch) R410A Price$ Excl.
GST
J1355 1.5/8"
J1361 2.1/8"
J1366 2.5/8"
J1367 3.1/8"
158Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Tube
& F
ittin
gs
Flare Nuts - Short BarrelRealcoldStock No.
Size (Inch) Price$ Excl.
GST
J0401 1/4" FF
J0402 5/16" FF
J0403 3/8" FF
J0404 1/2" FF
J0405 5/8" FF
J0406 3/4" FF
TUBE & FITTINGSBRASS FITTINGS
Flare Nuts - Reducing BarrelRealcoldStock No.
Size (Inch) Price$ Excl.
GST
J0421 3/8" MF - 1/4" Tube
J0422 1/2" MF - 3/8" Tube
J0423 5/8" MF - 1/2" Tube
Flare Seal CapsRealcoldStock No.
Size (Inch) Price$ Excl.
GST
J0770 1/4” Flare
J0771 5/16” Flare
J0772 3/8" Flare
J0773 1/2" Flare
J0774 5/8" Flare
Male Flare UnionRealcoldStock No.
Size (Inch) Price$ Excl.
GST
J0431 1/4" MF x 1/4" MF
J0432 5/16" MF x 5/16” MF
J0433 3/8" MF x 3/8" MF
J0434 1/2" MF x 1/2" MF
J0435 5/8" MF x 5/8" MF
J0436 3/4" MF x 3/4" MF
Male Flare Reducing UnionRealcoldStock No.
Size (Inch) Price$ Excl.
GST
J0452 3/8" MF x 1/4" MF
J0454 1/2" MF x 1/4" MF
J0456 1/2" MF x 3/8" MF
J0459 5/8" MF x 3/8" MF
J0460 5/8" MF x 1/2" MF
J0464 3/4" MF x 1/2" MF
J0465 3/4" MF x 5/8" MF
Female Flare Swivel UnionRealcoldStock No.
Size (Inch) Price$ Excl.
GST
J0541 1/4" FF Connectors
J0543 3/8" FF Connectors
J0544 1/2" FF Connectors
J0545 5/8" FF Connectors
Female Flare ConnectorsRealcoldStock No.
Size (Inch) Price$ Excl.
GST
J0551 1/4" FF c/w Gaskets
J0553 3/8" FF c/w Gaskets
J0554 1/2" FF c/w Gaskets
Male Flare to Female Pipe Reducing UnionRealcoldStock No.
Size (Inch) Price$ Excl.
GSTMF FP
J0536 1/4” 1/8”
J0537 1/4” 1/4”
J0538 1/4” 3/8”
J0535 3/8” 1/2”
159Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Tube
& F
ittin
gsTUBE & FITTINGSBRASS FITTINGS
Male Flare to Male Pipe UnionRealcoldStock No.
Size (Inch) Price$ Excl.
GSTMF MBSP
J0501 1/4” 1/8”
J0501A 5/16 1/8
J0502 1/4” 1/4”
J0502A 5/16 1/4
J0504 1/4” 3/8”
J0507 3/8” 1/8”
J0508 3/8” 1/4”
J0510 3/8” 3/8”
J0511 3/8” 1/2”
J0515 1/2” 1/4”
J0517 1/2” 3/8”
J0518 1/2” 1/2”
J0523 5/8” 3/8”
J0524 5/8” 1/2”
J0530 3/4” 1/2”
J0531 3/4” 3/4”
ACME AdapterRealcoldStock No.
Size (Inch) Price$ Excl.
GST
J0742 1/4" FF - 1/2" Male
J0743 1/2" FF - 1/4" MF
J074414 mm Male - 1/4” MF (Suits Auto A/C Couplers)
Male Flare to MNPT SchraderRealcoldStock No.
Size (Inch) Price$ Excl.
GSTMF MNPT
T0320 1/4” 1/8”
T0326 1/4” 1/4”
Male Flare to Male Pipe ElbowsRealcoldStock No.
Size (Inch) Price$ Excl.
GSTMF MBSP
J0590 1/4" 1/8"
J0591 1/4" 1/4"
J0592 1/4" 3/8"
J0594 3/8" 1/4"
J0595 3/8" 3/8"
J0601 5/8" 1/2"
J0604 3/4" 3/4"
Cylinder Adapters & SparesRealcoldStock No.
Size (Inch) Price$ Excl.
GSTMF FBSP
J0539 1/4” 3/4”
J0540 3/8” 3/4”
Double Male Flare ElbowsRealcoldStock No.
Size (Inch) Price$ Excl.
GST
J0561 1/4" Male Flare
J0563 3/8" Male Flare
J0564 1/2" Male Flare
J0565 5/8" Male Flare
J0566 3/4" Male Flare
Male Flare to Female Flare Reducing UnionRealcoldStock No.
Size (Inch) Price$ Excl.
GSTMF FF
J0472 1/4 3/8
J0474 1/4 1/2
J0475 3/8 1/2
J0479 3/8 1/4
J0486 1/2 3/8
J0488 1/2 5/8
J0491 5/8 1/2
160Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Tube
& F
ittin
gs
TUBE & FITTINGSBRASS FITTINGS
Pipe Bushings MBSPRealcoldStock No.
Size (Inch) Price$ Excl.
GSTMBSP FBSP
J0750 1/4" 1/8"
J0752 3/8" 1/4"
J0754 1/2" 3/8"
J0756 3/4" 1/2"
J0739 1/8" 1/8"
J0740 1/4" 1/4"
Male Flare TeesRealcoldStock No.
Size (Inch) Price$ Excl.
GST
J0610 1/4" MF
J0612 3/8" MF
J0613 1/2" MF
J0614 5/8" MF
Male Flare to Male BSP TeesRealcoldStock No.
Size (Inch) Price$ Excl.
GST
J0617 1/4" MFx1/4" MFx1/8" MP
J0618 1/4" MFx1/4" MFx1/4" MP
J0619 3/8" MFx3/8" MFx1/4" MP
J0620 1/4" MFx1/4" MFx1/4" FF
Schrader Valve TeesRealcoldStock No.
Size (Inch) Price$ Excl.
GST
T0328 1/4"Schr x 1/4"Schr x 1/8" MNPT
T0330 1/4" Schr onto 1/4" tube
T0332 5/16" Schr onto 3/8" tube
T0350 1/4" FF Swivel x 1/4" Schr x 1/4" MF
Male Flare Seal PlugsRealcoldStock No.
Size (Inch) Price$ Excl.
GST
J0690 1/4” MF
J0691 5/16” MF
J0692 3/8" MF
J0693 1/2" MF
J0694 5/8" MF
J0695 3/4" MF
Male Plugs MBSPRealcoldStock No.
Size (Inch) Price$ Excl.
GST
J0731 1/4" MP
J0732 3/8" MP
J0733 1/2" MP
161Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Tube
& F
ittin
gs
Line Tap ValvesNeedle automatically retracts to permit unrestricted flow.
RealcoldStock No.
Description Price$ Excl. GST
T0309 A-1 Line Tap Valve to suit 1/4”, 5/16” and 3/8” OD tube
T0310 Supco Bullet Piercing Valve for 1/4”, 5/16” and 3/8” tube T0309 T0310
T0080 T0322
T0324
T0358
T0365
Schrader Valves / Access Ports RealcoldStock No.
Description Price$ Excl. GST
T0080 Access Port sweats into 1/4” tube or 3/8” tube
T0322 Access Port 9-way multi-fitting 1/8” through 1/2”
T0324 Access Port with 50 mm 1/4” OD copper tail
T0325 Access Valve 1/4” Flare by 5/16” OD tube
T0358 Quick Seal Nut 1/4” Flare
T0360 Valve Core Remover with Core Storage Facility
T0365 Schrader Valve Core
T0370 Schrader Valve Core - Suitable for R410A
TUBE & FITTINGSACCESSORIES
162Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Tube
& F
ittin
gs
Suitable For All HFC, HCFC RefrigerantsDesigned for installation in air conditioning and refrigeration piping to minimise transmission of vibration from the compressor or other parts of the system.
RealcoldStock No.
ODS Laying Length Price$ Excl. GST
F0475 3/8" 210 mm
F0476 1/2" 230 mm
F0477 5/8" 247 mm
F0478 3/4" 260 mm
F0479 7/8" 292 mm
F0481 1.1/8" 332 mm
F0482 1.3/8" 380 mm
F0483 1.5/8" 435 mm
F0484 2.1/8" 510 mm
F0485 2.5/8" 609 mm
F0486 3.1/8" 686 mm
Vibration PadISO Cube is a natural rubber pad, designed to reduce vibration and noise emanating from refrigeration and air conditioning equipment. Circular design of each pad offers a suction cup effect, which eliminates the need to bolt the pad down. Standard pad is divided into 81-50 mm segments. These 50 durometer pads will withstand a load of 180 psi per each 50 mm square.
To prolong machine life, reduce maintenance cost and dampen vibration. Resists: water, aging, oil & compression set. Recommended maximum load capacity: 50 pounds per square inch.
RealcoldStock No.
Description Price$ Excl. GST
V0265ISO Cube Vibration Pad 8t CubesISO-18 450 mm x 450 mm x 19 mm
V0290ISO Cube Vibration Pad Single Square50 mm x 50 mm x 19 mm
V0271 MA-Line Solid Rubber Pad 455 mm x 455 mm x 5 mm
Vibration Eliminators - Installation Hints
Install the unit as close to the compressor as possible, and at right angles to the vibration motion. Anchor the refrigerant piping at the end of the unit furthest away from the vibration source. Allow sufficient space for the unit so that it will not be subject to static compression or tension after brazing it into place. Units should be installed in a straight line; they are not intended to compensate for offset piping.
If the unit is installed in an area where condensate can accumulate on it, cover the unit with a waterproof barrier to prevent moisture from freezing under the braid and ferrules, causing the unit to rupture. Care should be taken when making the sweat connections - direct the torch flame away from the braid and clean excess flux from the unit.
For situations of severe vibration, install two units in series at right angles to one another.
TUBE & FITTINGSVIBRATION ELIMINATORS
163Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Tube
& F
ittin
gsTUBE & FITTINGS
INSULATION
10 mm Wall Closed Cell Pipe InsulationRealcoldStock No.
ID LGTHS per carton
Price$ Excl.
GSTInches mm
N4006FR 1/4" 6 132
13 mm Wall Closed Cell Pipe InsulationRealcoldStock No.
ID LGTHS per carton
Price$ Excl.
GSTInches mm
N4109FR 3/8” 9 70
N4113FR 1/2" 13 60
N4116FR 5/8" 16 50
N4119FR 3/4" 19 40
N4122FR 7/8" 22 32
N4125FR 1” 25 30
N4128FR 1.1/8" 28 28
N4135FR 1.3/8" 35 20
19 mm Wall Closed Cell Pipe InsulationRealcoldStock No.
ID LGTHS per carton
Price$ Excl.
GSTInches mm
N4209FR 3/8" 9 32
N4213FR 1/2" 13 32
N4216FR 5/8" 16 28
N4219FR 3/4" 19 24
N4222FR 7/8" 22 20
N4228FR 1.1/8" 28 18
N4235FR 1.3/8" 35 16
N4242FR 1.5/8" 42 12
25 mm Wall Closed Cell Pipe InsulationRealcoldStock No.
ID LGTHS per carton
Price$ Excl.
GSTInches mm
N4319FR 3/4” 19 18
N4322FR 7/8" 22 16
N4328FR 1.1/8" 28 12
N4335FR 1.3/8" 35 10
N4342FR 1.5/8" 42 8
RealcoldStock No.
ID LGTHS per carton
Price$ Excl.
GSTInches mm
N4142FR 1.5/8" 42 18
N4148FR 1.7/8" 48 16
N4154FR 2.1/8" 54 14
N4160FR 2.3/8" 60 12
N4167FR 2.5/8" 67 10
N4180FR 3.1/8" 80 8
N4190FR 3.1/2” 90 8
RealcoldStock No.
ID LGTHS per carton
Price$ Excl.
GSTInches mm
N4248FR 1.7/8" 48 10
N4254FR 2.1/8" 54 8
N4260FR 2.3/8" 60 8
N4267FR 2.5/8" 67 8
N4276FR 3” 76 6
N4280FR 3.1/8" 80 6
N4290FR 3.1/2" 90 6
RealcoldStock No.
ID LGTHS per carton
Price$ Excl.
GSTInches mm
N4348FR 1.7/8" 48 8
N4354FR 2.1/8" 54 8
N4360FR 2.3/8” 60 6
N4367FR 2.5/8" 67 6
N4380FR 3.1/8" 80 6
Maxflex expanded closed cell structure provides a high insulation factor combined with a strong vapour barrier and a high resist-ants to ozone and ultraviolet light. This combination provides long term prevention of condensation or frost formation on refrigeration piping and chilled water lines. Maxflex is also self extinguishing in nature. Tested in Accordance with AS/ANZS 1530.30.1999.
164Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Tube
& F
ittin
gs
Sheet InsulationRealcoldStock No.
Description Price$ Excl. GST
N4513FR 2.0m x 1.0m x 13 mm 20 sheets/ctn
N4519FR 2.0m x 1.0m x 19 mm 10 sheets/ctn
N4525FR 2.0m x 1.0m x 25 mm 8 sheets/ctn
TUBE & FITTINGSINSULATION
Roll InsulationRealcoldStock No.
Description Price$ Excl. GST
N4406FR 1.0m x 22.0m x 6 mm Rolls
N4413FR 1.0m x 11.0m x 13 mm Rolls
N4419FR 1.0m x 7.0m x 19 mm Rolls
Note: Maxflex products complies to standard AS/ANZS 1530.30:1999.
SpecificationsPhysical Properties Maxflex Test Method
Cell Structure Closed Cell -Density Ibs/ft³ (g/cm³) 3-6 (0.048-0.096) ASTM D 1667
Thermal Conductivity BTU. in/ft² hr. °F(W/mK)
Mean Temp. -4°F (-20°C)
32°F (0°C)
75°F (24°C)
90°F (32°C)
104°F (40°C)
ASTM C177JIS A1412DIN 52613K-Value 0.22
0.0320.23 0.034
0.25 0.037
0.26 0.038
0.27 0.039
Service Temperature-70°F to 257°F-57°C to 125°C
Maxflex becomes hard at -57°CBut can be used even at -200°C
Water Vapour Permeability (kg/Pa.s.m) 0.10 perm-in (0.15 x 10-12)ASTM C 355ASTM E96
Moisture Resistance (μ value) μ not less than 5000 DIN 52615Water Absorption (weight %) Not more than 3% ASTM D 1056Ozone Resistance No crack ASTM D 1171Heat Stability (% shrinkage) At 200 °F and 220 °F for 7 days 4.5 and 5.5 respectively ASTM C 534
Flammability & Smoke Density
Class VO UL – 94Self-extinguishing ASTM D 635
Class 1 BS476 Part 7 1987Class 0 BS476 Part 6 1987
Smoke density 80 ASTM-E84 (15 mm thick)U.V Weather Resistance Excellent -Nitrosamine Contents Not detected U.S FDAFlexibility Excellent -
165Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Tube
& F
ittin
gs
Insulation TapeRealcoldStock No.
Description Price$ Excl. GST
N4606FR
Maxflex Foam Tape Closed cells elastomeric, black colour, one side adhesive with protective film. Used for hot and cold pipe insulation. Can be used as joint protection.48 mm x 15 metres roll - self adhering
N2510 Cork Tape
Electrical Insulation TapeRealcoldStock No.
Description Price$ Excl. GST
N0185 Insulation Tape - 48 mm x 30 metres roll - self adhering Black PVC
N0186 Insulation Tape - 48 mm x 30 metres roll - self adhering White PVC
N0187 Insulation Tape - 48 mm x 30 metres roll - self adhering PVC (heavy grade)
N0420 Electrical Tape 19 mm x 20 metres Black
N0421 Electrical Tape 19 mm x 20 metres Red
N0422 Hellerman Electrical Tape 19 mm x 20 metres Yellow
N0423 Electrical Tape 19 mm x 20 metres Blue
N0424 Hellerman Electrical Tape 19 mm x 20 metres Green
Duct TapeRealcoldStock No.
Description Price$ Excl. GST
N0402 Aluminium Duct Tape - 51 mm x 45.72 metres roll
N0404 Silver Duct Tape - 51 mm x 54.86 metres roll
Petroleum TapeRealcoldStock No.
Description Price$ Excl. GST
N0406 Denso Tape 50 mm x 10 metres roll
N0407 Denso Tape 100 mm x 10 metres roll
Note: Maxflex products complies to standard AS/ANZS 1530.30:1999.
TUBE & FITTINGSINSULATION
H2 Insulation AdhesiveRealcoldStock No.
Description Pack Size Price$ Excl. GST
N0170 H2 Insulation Adhesive 125ml
N0172 H2 Insulation Adhesive 250ml
N0180 H2 Insulation Adhesive 192gm Tin
166Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Tube
& F
ittin
gs
Accessories, Sealing, Jointing CompoundsRealcoldStock No.
Description Sold Per Price$ Excl. GST
Sealing Compounds
N0512 Holdfast Bison Silicone Sealant (White) 375ml Tube
N0515 Holdfast Fix all 220 Sealant White 425g Tube
N0519 Holdfast Silaseal Silicone Sealant (Clear) 310ml Tube
N0190 Holdfast Nailpower FR Expanding Foam 750ml Aerosol Can
N0191 Holdfast Foam Cleaner 500ml Aerosol Can
N0192 Holdfast Spare Nozzle Pack of 4
Thermal Mastic
N0020 Presstite Thermal Mastic 3.8 Litre Tin
N0021 Presstite Thermal Mastic 225gm Tube
Note: A heat conducting compound - increases heat transfer at four times the rate obtained with mechanical mounting.
N0020
N0512
N0021
TUBE & FITTINGSACCESSORIES
Dektite Pipe Flashing - Square BaseDektite provides a durable maintenance-free seal, no matter what profile or diameter pipe
RealcoldStock No.
Model Description Price$ Excl. GST
N0500 DB0-35 Mini Dektite Ideal for cable or conduit 0 - 35 mm
N0501 DB5-55 Dektite to 5 - 55 mm
N0502 DB50-70 Dektite to 50 - 70 mm
N0507 DB25-100 Dektite to 5 - 127 mm
N0504 DB110-160 Dektite 75 - 175 mm
N0505 DB160-220 Dektite to 100 - 200 mm
N0506 DB220-300 Dektite 160 - 300 mm
N0521 RF801G Round Base
Dektite 20 - 70 mm Retrofit: for existing and fixed piping
N0495 Top-Hat Roof penetration kit 65 mm
N0496 Top-Hat Roof penetration kit 110 mm
Note: Material Safety Data Sheets are available, upon request, for hazardous substances.
N0502
Hand Pour Foam SystemRealcoldStock No.
Description Pack Size Price$ Excl. GST
N0197 Endurathane 3245N-100R Foam Kit 2 x 1kg
N0198 Endurathane 3245N-100R Foam Kit 2 x 5kg
167Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Tube
& F
ittin
gs
InsulclampTube and pipe support. INSULCLAMP - effective pipe support and good isolation properties reduce transmission of vibration and noise. Withstands temperatures from -30ºC to +125ºC, good resistance to oil, UV rays etc.
RealcoldStock No.
Size Description Sold Per Price$ Excl. GST
A (mm) B (mm)
J1602 1/4" 31.80 7.9 each
J1603 3/8” 34.93 19.05 each
J1604 1/2” 38.10 23.81 each
J1605 5/8” 42.75 25.40 each
J1606 3/4” 44.45 30.16 each
J1607 7/8” 49.21 33.34 each
J1608 1.1/8” 53.98 36.51 each
J1609 1.3/8” 60.33 44.45 each
J1610 1.5/8” 73.03 53.98 each
J1611 2.1/8” 88.90 68.26 each
J1612 2.5/8” 101.60 80.96 each
J1613 3.1/8” 114.30 93.66 each
J1614 4.1/8" 139.70 146.05 each
J1620 40 x 20mm Aluminium Channel 1 metre lengths length
Studding ClipThe Studding Clip is a plastic clip for supporting copper tube or PVC pipe.
RealcoldStock No.
Description Sold Per Price$ Excl. GST
J1688 15 mm Studding Clip each
J1681 22 mm Studding Clip each
J1682 25 mm Studding Clip each
J1683 28 mm Studding Clip each
J1684 32 mm Studding Clip each
J1685 35 mm Studding Clip each
J1686 42 mm Studding Clip each
J1687 54 mm Studding Clip each
AC1205 Galvanised steel channel 3 metre length M1000
TUBE & FITTINGSTUBE & PIPE SUPPORT
168Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Tube
& F
ittin
gs
Copper Saddles - SingleRealcoldStock No.
Size (Inch) Price$ Excl.
GST
J2010 1/4”
J2011 3/8”
J2012 1/2”
J2013 5/8”
J2014 3/4”
J2015 7/8”
J2017 1.1/8”
J2018 1.3/8”
J2019 1.5/8”
J2020 2.1/8”
TUBE & FITTINGSTUBE & PIPE SUPPORT
Pipe Clamps - BrassRealcoldStock No.
Size (Inch) Price$ Excl.
GST
J1249 for 5/8" OD tube
J1250 for 7/8" OD tube
J1251 for 1.1/8" OD tube
J1253 for 1.5/8" OD tube
J1254 for 2.1/8" OD tube
J1255 for 2.5/8" OD tube
J1257 Brass Plate tapped to 10 mm
J1258 Screwed Brass Rod 10 mm x 610 mm long
J1259 Brass Nut 10 mm (for locking rod)
169Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Tube
& F
ittin
gs
BBJ Pipe FittingsRealcoldStock No.
Description Height Width Depth Approx Pipe Size + Insulation
Price$ Excl. GST
J1650 BBJ Suspender # 2 75 mm 55 mm 35 mm 5/8” gas, 3/8” liquid
J1651 BBJ Suspender # 3 87 mm 62 mm 35 mm 7/8” gas, 1/2” liquid
J1652 BBJ Suspender # 4 100 mm 70 mm 35 mm 1.1/8” gas, 5/8” liquid
J1660 BBJ Griplock # 1 30 mm 54 mm — 1/2” gas, 1/4” liquid
J1661 BBJ Griplock # 2 32 mm 60 mm — 5/8” gas, 3/8” liquid
J1662 BBJ Griplock # 3 37 mm 67 mm — 7/8” gas, 1/2” liquid
J1663 BBJ Griplock # 4 46 mm 80 mm — 1.1/8” gas, 5/8” liquid
J1672 BBJ Pipe Tie Base BH3
J1674 BBJ Pipe Tie 250 mm
J1675 BBJ Pipe Tie 300 mm
J1676 BBJ Pipe Tie 350 mm
J1677 BBJ Pipe Tie 400 mm
TUBE & FITTINGSTUBE & PIPE SUPPORT
Fasteners - Cable TiesRealcoldStock No.
Description Quantity Per Pack
Price per Pack$ Excl. GST
H0085 2.5 x 100 mm Black 100
H0086 3.5 x 150 mm Natural 100
H0087 3.5 x 150 mm Black 100
H0088 4.6 x 200 mm Natural 100
H0089 4.6 x 200 mm Black 100
H0090 4.6 x 385 mm Black 100
H0091 4.6 x 385 mm Natural 100
H0095 7.6 x 390 mm Black 100
H0096 7.6 x 465 mm Natural 100
H0098 7.6 x 760 mm Black 50
H0086
170Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Tube
& F
ittin
gs
RealcoldStock No.
Description Price$ Excl. GST
Threaded Sealants
N0058 Nylog Blue 30ml POE Oil Sys.
N0059 Nylog Red 30ml Mineral Oil Sys.
N0063 Leak-Lock 1oz Tube
N0065Leak-Lock Brush Top Plastic Jar 4oz Tube
N0069 Teflon Thread Seal Tape 12 mm x 10m
Simplefix Multi Purpose - Pipe Support Systems
J1265 Simplefix 100 m ZP Backing Plate
J1270Simplefix Strap (galv.) 25 metre x 0.6 mm
J1271 5 metre x 0.6 mm
J1275Rubber Insertion Strip 5 metre coil
J1279 Top Bracket
Fittings & FastenersRealcoldStock No.
Description Price$ Excl. GST
Simplefix Tube Hangers Hinged
J1701 Hinged 1/2-5/8
J1702 Hinged 5/8-3/4
J1703 Hinged 7/8
J1704 Hinged 1.1/8
J1705 Hinged 1.3/8
J1706 Hinged 1.5/8
J1708 Hinged 2.1/8
J1710 Hinged 2.5/8
J1713 Hinged 3.1/8
Simplefix Tube Hangers Heavy Duty
J1720 Heavy Duty 3/8-1/2
J1721 Heavy Duty 1/2-5/8
J1722 Heavy Duty 3/4
J1723 Heavy Duty 7/8
J1724 Heavy Duty 1.1/8
J1725 Heavy Duty 1.3/8
J1726 Heavy Duty 1.5/8
J1728 Heavy Duty 2.1/8
J1730 Heavy Duty 2.5/8
J1733 Heavy Duty 3.1/8
ZP Threaded Rod (galvanised)
J1264 10 mm, Zinc Plated Nut Jar 100
J1263 10 mm x 32 mm Penny Washer
J1265 10 mm ZP Backing Plate
J1260 10 mm ZP Rod 1m
J1261 10 mm ZP Rod 2m
Realcold offer a comprehensive range of screws and fastenings. Visit your store to view the full range.
TUBE & FITTINGSTUBE & PIPE SUPPORT
Quick Positioning ClipRealcoldStock No.
Description Price$ Excl. GST
J1633 3/8” Clip
J1634 1/2” Clip
J1635 5/8” Clip
J1636 3/4” Clip
J1637 7/8” Clip
J1638 1 1/8” Clip
J1639 1 3/8” Clip
J1633
171Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Tube
& F
ittin
gs
Condensate Drain Pipe & FittingsRealcoldStock No.
Description Price$ Excl. GST
uPVC Pressure Pipe Air Cond & Refrig Drain Pipe
AC1001 15 mm (3.9 Metre Length) white
AC1003 20 mm (3.9 Metre Length) white
AC1005 25 mm (3.9 Metre Length) white
uPVC Pressure Pipe 90 Deg Elbow
AC1010 15 mm 90 deg Elbow
AC1012 20 mm 90 deg Elbow
AC1014 25 mm 90 deg Elbow
uPVC Pressure Pipe 45 Deg Elbow
AC1018 15 mm 45 deg Elbow
AC1020 20 mm 45 deg Elbow
AC1022 25 mm 45 deg Elbow
uPVC Pressure Pipe Equal Tee
AC1028 15 mm Equal Tee
AC1030 20 mm Equal Tee
AC1032 25 mm Equal Tee
uPVC Pressure Pipe Double Ended Socket
AC1036 15 mm Double Ended Socket
AC1038 20 mm Double Ended Socket
AC1040 25 mm Double Ended Socket
TUBE & FITTINGSPVC PIPE & FITTINGS
RealcoldStock No.
Description Price$ Excl. GST
uPVC Pressure Pipe Reducing Socket
AC1044 20 x 15 mm Reducing Socket
AC1046 25 x 15 mm Reducing Socket
AC1048 25 x 20 mm Reducing Socket
uPVC Pressure Pipe Reducing Bush
AC1052 20 x 15 mm Reducing Bush
AC1054 25 x 15 mm Reducing Bush
AC1056 25 x 20 mm Reducing Bush
uPVC Pressure Pipe Threaded Socket Male (grey)
AC1060 15 mm Threaded Socket Male
AC1062 20 mm Threaded Socket Male
AC1064 25 mm Threaded Socket Male
uPVC Pressure Pipe Threaded Socket Female (grey)
AC1070 15 mm Threaded Socket Female
AC1072 20 mm Threaded Socket Female
AC1074 25 mm Threaded Socket Female
Socket Union
AC1110 15 mm Socket Union / Connection
AC1112 20 mm Socket Union / Connection
AC1114 25 mm Socket Union / Connection
172Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Tube
& F
ittin
gs
Condensate Drain Pipe & FittingsRealcoldStock No.
Description Price$ Excl. GST
Solvent (Clear)
AC1078 125 ml Clear Solvent Type P
AC1080 250 ml Clear Solvent Type P
White Pipe Saddle (full)
AC1090 Full Pipe Saddle 15 mm
AC1092 Full Pipe Saddle 20 mm
AC1094 Full Pipe Saddle 25 mm
Zinc Plated Pipe Saddle (Single side)
AC1096 Single Sided Clip 15 mm
AC1098 Single Sided Clip 20 mm
EZ Trap - The Trap ExpertsRealcoldStock No.
Description Price$ Excl. GST
20 mm Transparent J Trap
AC1102 J Trap
Flexible Brush - Clean out your Trap
AC1108 Flexible Brush
TUBE & FITTINGSPVC PIPE & FITTINGS
Vision Trap DrainRealcoldStock No.
Description Price$ Excl. GST
AC1150 Vision Trap Drain
173Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Har
dwar
eHARDWARE
FASTENINGS
FasteningsRealcoldStock No.
Description Size Head Quantity Price$ Excl. GST
J4049 Stainless Steel Self Tapper 8g x 1/2" Square Drive Pk50
J4050 Stainless Steel Self Tapper 8g x 3/4" Square Drive Pk45
J4051 Stainless Steel Self Tapper 8g x 1" Square Drive Pk40
J4053 Stainless Steel Self Tapper 10g x 1/2" Square Drive Pk30
J4054 Stainless Steel Self Tapper 10g x 3/4" Square Drive Pk25
J4055 Stainless Steel Self Tapper 10g x 1" Square Drive Pk25
J4072 Surefast Countersunk 6g x 3/4" Square Drive Pk650
J4073 Surefast Countersunk 6g x 1" Square Drive Pk475
J4074 Surefast Countersunk 6g x 1 1/4" Square Drive Pk400
J4075 Surefast Countersunk 8g x 3/4" Square Drive Pk550
J4076 Surefast Countersunk 8g x 1" Square Drive Pk450
J4077 Surefast Countersunk 8g x 1 1/4" Square Drive Pk335
J4018 Surefast Countersunk 8g x 1 1/2" Square Drive Pk200
J4078 Surefast Countersunk 8g x 1 3/4" Square Drive Pk200
J4079 Surefast Countersunk 8g x 2" Square Drive Pk160
J4064 Surefast Countersunk 9g x 3/4" Square Drive Pk100
J4066 Surefast Countersunk 9g x 1 1/4" Square Drive Pk100
J4067 Surefast Countersunk 9g x 2" Square Drive Pk50
J4082 Surefast Countersunk 10g x 3" Square Drive Pk100
J4059 Metal Piercing Wafer Head Tek Screw 8g x 12 mm Pozi Drive Pk150
J4060 Metal Piercing Wafer Head Tek Screw 8g x 25 mm Pozi Drive Pk125
J4056 Tek Screws Stainless Steel 10g x 12 mm Square Drive Pk100
J4057 Tek Screws Stainless Steel 10g x 16 mm Square Drive Pk90
J4058 Tek Screws Stainless Steel 10g x 20 mm Square Drive Pk55
J4013 Tek Screws Metal Galv Class 3 10g x 25 mm Hex Head Pk50
J4070 Tek Screws Metal Galv Class 3 12g x 25 mm Hex Head Pk70
J4071 Tek Screws Metal Galv Class 3 12g x 45 mm Hex Head Pk40
J4007 Tek Screws Wood T17 Class 2 12g x 25 mm Hex Head Pk95
J4069 Tek Screws Wood T17 Class 2 12g x 40 mm Hex Head Pk60
J4008 Tek Screws Wood T17 Class 3 12g x 50 mm Hex Head Pk60
J4004 Powers Wall Dog Screw 8g x 32 mm Square Drive Pk100
J4041 Plaster Board Plastic Self Drill + Screw — Pzi/Sq Pk100
J4043 Plaster Board Metal Self Drill + Screw — Pzi/Sq Pk100
174Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Har
dwar
e
Fastening KitRealcoldStock No.
Description Price$ Excl. GST
Fastening Kit
J4086
18 pcs fastening kitUnique storage for on-site and in a vehicleTough composite storage boxBelt clip on transparent containers
HARDWAREFASTENINGS
FasteningsRealcoldStock No.
Description Size Quantity Price$ Excl. GST
J4002 Nylon Wall Plug 5g x 25 mm Pk190
J4003 Nylon Wall Plug 6g x 30 mm Pk170
J4044 Hollow Wall Anchor 4g x 40 mm Pk20
J4045 Hollow Wall Anchor 4g x 55 mm Pk19
J4046 Hollow Wall Anchor 6g x 40 mm Pk11
J4000 Nylon Anchor 5.0 mm x 25 mm Pk100
J4001 Nylon Anchor 6.5 mm x 38 mm Pk45
J4061 Rivets Aluminium 1/8"D x 1/4"L Pk100
J4062 Rivets Aluminium 1/8"D x 5/16"L Pk100
J4063 Rivets Aluminium 1/8"D x 3/8"L Pk100
J4030 Rivets Aluminium 1/8"D x 1/2"L Pk100
J4033 Rivets Aluminium 5/32"D x 1/4"L Pk100
J4034 Rivets Aluminium 5/32"D x 3/8"L Pk100
J4035 Rivets Stainless Steel 1/8"D x 1/4"L Pk100
J4036 Rivets Stainless Steel 1/8"D x 5/16"L Pk100
J4037 Rivets Stainless Steel 1/8"D x 3/8"L Pk100
175Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Har
dwar
e
LocksetsRealcoldStock No.
Model Description Price$ Excl. GST
V0116 Efco style R5710 supplied complete with strike. Lockable handle.
V0121 Efco style R5612 complete with internal release. Adjustable strike, offset 16 - 32 mm
V0300 Shineyear CH1178 complete with internal release. Adjustable strike, offset 45 -70 mm
V0356 Shineyear Internal Release Mechanism to suit CT/CH-1178
V0302 Shineyear CH-1200P Edgemount. Adj. strike, offset 18 - 22 mm
HingesRealcoldStock No.
Model Description Approx.Overall Length
AdjustableOffset
Price$ Excl. GST
V0151 Efco R40 110 mm 19 - 25 mm
V0316 Shineyear CH1450 250 mm 32 - 50 mm
V0318 Shineyear CH1460 250 mm 32 - 60 mm
V0320 Shineyear CH1470 335 mm 40 - 70 mm
Style Spares - EfcoRealcoldStock No.
Description Price$ Excl. GST
V0117 Efco R5722 strike for R5712 and R5710. Adjustable offset 19 to 25 mm
V0122 Efco R5622 strike for R5612. Adjustable offset 0 to 16 mm
V0124 Efco R5612 Internal Release Handle for R5612
V0126 Efco V26A Push Rod for R5612
V0128 Efco Spring to suit R5612
V0116
V0121
V0300
V0151
V0316
Accessories - Efco
A. V0126
B. V0124
C. V0117
D. V0122/3
A
B
DC
AccessoriesRealcoldStock No.
Description Sold per Price$ Excl. GST
V0245 ‘R’ Section rubber door gasket (random coils to 40m) metre
V0250 Windlace 12 mm diam. sponge rubber core with black fabric covering (30m coils) metre
HARDWARELOCKSETS & HINGES
V0245V0250
176Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Fan
Mot
ors
Fan MotorsRealcoldStock No.
Watts Rpm Shaft Mounting/Models
Price$ Excl. GST
D0121 4 2400 3/16” 2 bolt 50 mm spacing
D0122 7 1300 D.Plate 3 bolt rear
D0165 10 Low Temp 1300 D.Plate 3 bolt rear
D0123 10 1300 D.Plate 4 bolt
D0124 16 1300 D.Plate 4 bolt Rondo 140-700 CM
D0125 25 1300 D.Plate Rear tapped 4 bolt
D0129 25 1300 8 mm 3 bolt rear 2 bolt bottom
D0137 90 1440 1/2" 120 x 216 Base - complete L’Unite unit spare
D0169 180 1380 1/2" Fan motor
AccessoriesRealcoldStock No.
Description Price$ Excl. GST
D0240 Capacitor 5 mfd suits D0230, D0231
D0241 Capacitor 12.5 mfd suits D0232
Features & Benefits
• Motors Single Phase 50/60Hz (Check first)• CCW = Counter Clockwise - Facing Shaft• CW = Clockwise Facing Shaft• Note: 3 bolt mount 70 mm PCD - 4 bolt mount 54 mm PCD
Bi Directional Fan MotorsRealcoldStock No.
Watts Rpm Shaft Mounting/Models
Price$ Excl. GST
D0160 40 1300 5/16" 3/4 bolt front and rear
D0162 20 1300 5/16" 3/4 bolt front/rear
D0133 60 1300 5/16" 3/4 bolt front and rear
FAN MOTORSFANS
D0137
Fan MotorsRealcoldStock No.
Watts Rpm Shaft Mounting/Models
Price$ Excl. GST
D0155 34 1300 D.Plate 3 or 4 bold rear / 2 bolt bottom
177Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Fan
Mot
ors
External Rotor Motor TypeRealcoldStock No.
Brand Description Diameter (mm)
Watts Rpm ApplicationInduce/Blower
Price$ Excl. GST
Diameter 300 mm
R0930 EBM 300 mm Fan Motor Assembly 1 phase 300 80 1380 Induce
M0159 Dunli Fan Motor Assembly 1 phase 300 — — Blower
Diameter 350 mm
R0935 EBM Fan Assembly 1 phase 350 130 1400 Induce
Diameter 400 mm
R0940 EBM 400 mm Fan Motor Assembly 1phase 400 180 1380 Induce
R0940B EBM 400 mm Fan Motor Assembly 1 phase 400 180 1380 Blower
Diameter 450 mm
R0945 EBM450 mm Condensor Fan Motor Assembly 450W 1 phase
450 350 1325 Induce
Diameter 500 mm
R0950 EBM 500 mm Fan Motor Assembly 1 phase 500 420 1300 Induce
Diameter 630 mm
R0963 EBM 630 mm Fan Motor Assembly 3 phase 630 880 1320 Induce
Compact Fan Motor Assembly - Computer Rooms etc.RealcoldStock No.
Brand Description Diameter (mm)
Watts Rpm ApplicationInduce/Blower
Price$ Excl. GST
D0150 EBMMotor Assembly - fan and guard. 172 x 150 x 55 mm
150 45/39 2800 Induce
D0152 EBM28W Motor Assembly - fan and guard. 172 x 150 x 38 mm
150 29 2800 Induce
D0154 EBM 19W Motor Assembly - fan 120 x 120 x 38 mm 120 19 2650 Induce
Blade & Motor Type - 3 Piece Fan AssemblyRealcoldStock No.
Brand Description Diameter (mm)
Watts Rpm ApplicationInduce/Blower
Price$ Excl. GST
D0200Supco SM672 Universal Motor Kit - Single Speed Bi Directional c/w 2 blades and accessories
100/138 5 3000 Induce/ Blower
FAN MOTORSFAN MOTOR ASSEMBLY
178Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Fan
Mot
ors
Fan BladesRealcoldOr der No.
Description Price$ Excl. GST
Diameter Blade Pitch Rotation Min. Watts
Bore
Induced Type
D0105 178 mm Postmix 5 40° CCW 7 Driveplate
D0106 200 mm (8”) 5 40° CCW 10 Driveplate
D0107 229 mm Skope/Cyclone 5 40° CCW 22 Driveplate
D0111 200 mm (7.7/8”) 5 28° CCW 5 Driveplate
D0109 254 mm (10”) 5 30° CCW 22 8 mm
D0118 254 mm (10”) 5 25° CCW 10 Driveplate
D0115 305 mm (12”) 3 20° CCW 22 Driveplate
Reverse Pitch (Blower Type)
D0309 254 mm (10”) 5 30° CCW 22 8 mm
Miscellaneous Fan Blades
D0015 100 mm (4”) 5 Plastic 30° CW
Blower 4 1/8"
D0027 125 mm (5”) 5 Plastic 25° CW
Blower 4 3/16"
M0165 862-022Y-1 (10”) 5 Plastic 30° CW
Blower 20 5/16"
M0166 862-717Y (7”) 3 Plastic 25° CCW
Induced 4 3/16"
D0105
D0116
FAN MOTORSFANS
179Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Che
mic
als
RefrigerantRealcoldStock No.
Product Charge Size/ Packaging Price$ Excl. GST
L0100 R134a Liquid or Vapour 13.5 Kg DAC
L0199 Isceon MO99 Liquid only 11.35 Kg
L0141 R404A Liquid only 10.9 Kg DAC
L0145 R507 Liquid only 11.3 Kg DAC
L0030 R22* Liquid or Vapour 13.5 Kg DAC
L0157 R407C Liquid Only 11.3 Kg DAC
L0161 R410A Liquid Only 11.3 Kg DAC
L0167 R407F Liquid Only 11.3 Kg DAC
* Note: HCFC refrigerants will be phased out by 2015 in accordance to the Ozone Layer Protection Act 1996.
Refrigerant LevyRealcoldStock No.
Description Size/ Packaging Price$ Excl. GST
Training Levy All refrigerants per Kg
Ozone Levy All refrigerants containing CFCs or HCFCs per Kg
Recovery CylindersManufactured to DOT-400 suitable for use with R410A refrigerant
RealcoldStock No.
Description Price$ Excl. GST
T2490M 10 Kg recovery cylinders
T2491M 20 Kg recovery cylinders
T2495M Mastercool recovery cylinders double VLV
Note: Go to www.realcold.co.nz to download a copy of the MSDS sheet/s.
CHEMICALSREFRIGERANT
T2491MT2490M
180Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Che
mic
als
CHEMICALSLUBRICANTS
Vacuum Pump LubricantsThis is a specially selected oil with a low vapour pressure and high stability for sealing.
RealcoldStock No.
Type Description Size Price$ Excl. GST
N0105M
Mastercool Vacuum Pump Oil
531 ml
N0106M 946 ml
N0109M 3.79 L
Note: Compressor lubricants are not suitable for vacuum pumps. Material Safety Data Sheets are available, upon request, for hazardous substances.
Mineral OilRealcoldStock No.
Type Application Size Price$ Excl. GST
N0531 Suniso 3GSLow / Med Temp
4 Litre
N0535 Suniso 3GS 20 Litre
N0541 Suniso 4GSMed / High Temp
4 Litre
N0545 Suniso 4GS 20 Litre
N0551 Suniso 5GS Automotive / Marine 4 Litre
Polyolester OilRealcoldStock No.
Type Application Size Price$ Excl. GST
N0581
Emkarate LE32 Low / Med Temp
1 Litre
N0580 4 Litre
N0579 20 Litre
N0582
Emkarate LE68 Med / High Temp
1 Litre
N0583 4 Litre
N0598 20 Litre
N0584 Emkarate RL100 H Automotive / Marine 1 Litre
Screw Compressor OilRealcoldStock No.
Type Description Size Price$ Excl. GST
C5864 FC 170
Screw Compressor Oil
19 Litre
C5860 FC 300 19 Litre
C5862 Frascold Oil R404A 20 Litre
Ammonia OilRealcoldStock No.
Type Description Size Price$ Excl. GST
N0560 Suniso 45A Ammonia Oil 20 Litre
N0531
N0580
181Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Che
mic
als
Coil and Filter CleanersFoam Brite Condenser Coil Cleaner - Non AcidicPenetrating non-acidic foaming action lifts and pushes contaminants and oxide off coils, including stubborn grease, tars and dirt, so that they can be rinsed away with water. Works in less than 5 minutes.
RealcoldStock No.
Description Pack Size Price$ Excl. GST
N0707 Greenleaf Foam Brite 1L spray
N0708 Greenleaf Foam Brite 5L
Evaporator Coil Cleaner - Self RinsingA clean evaporator is the first step in ensuring maximum efficiency. Greenleaf Evaporator Coil Cleaner is a safe, biodegradable alkaline self rinsing coil cleaner. It has a safe, non acidic formula which can be used indoors. NZFSA Approved C101.
RealcoldStock No.
Description Pack Size Price$ Excl. GST
N0727 Greenleaf Evaporator Coil Cleaner 1L spray
N0728 Greenleaf Evaporator Coil Cleaner 5L
N0729 Greenleaf Evaporator Coil Cleaner 20L
Clean-N-Safe ™A non-acid, non-caustic, non-corrosive evaporator and condenser coil cleaner. It is completely biodegradable and is safe for use around people, animals, aquatic life, and vegetation, USDA-H1.
RealcoldStock No.
Description Pack Size Price$ Excl. GST
N0721 Clean-N-Safe ™ Aerosol spray can 568gm
CF-20 Internal Coil System Cleaner & Acid NeutraliserReplaces R11 as a flushing agent. Environmentally safe, biodegradable interior coil cleaner for refrigeration and air conditioning systems. To clean interior coils after a compressor failure or burn-out and to remove mineral oil residue in preparation for retrofitting. ® ™ Registered trade mark of The Rectorseal Corporation.
RealcoldStock No.
Description Pack Size Price$ Excl. GST
N0820 Internal System Cleaner CF20 3.8L
CHEMICALSCLEANERS
182Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Che
mic
als
Eucalyptus All Purpose Cleaner & DegreaserA powerful all purpose cleaner & degreaser, with the added cleaning, deodorising and disinfecting power of natural eucalyptus oil. Sold as a concentrate. MAF approval C32.
RealcoldStock No.
Description Pack Size Price$ Excl. GST
N0752 Greenleaf All Purpose Cleaner 1L spray
N0753 Greenleaf All Purpose Cleaner 5L
N0754 Greenleaf All Purpose Cleaner 20L
Ice Machine Cleaner - Nickel SafeBiodegradable cleaner, specially formulated for removing scale deposits from ice machines with nickel or tin plated evaporators. Easy to use whilst providing a thoroughly clean machine. Sold as a concentrate.
RealcoldStock No.
Description Pack Size Price$ Excl. GST
N0712 Greenleaf Ice Machine Cleaner 1L
N0713 Greenleaf Ice Machine Cleaner 5L
KO Dirt BlasterHigh pressure cleaner- degreaser for filters, motors, relays, small condensers, etc. Blasts off dirt and grease without a rinse.Quick drying, electrically safe.
RealcoldStock No.
Description Pack Size Price$ Excl. GST
N0734 Stewart Hall KO Dirt Blaster - Aerosol 568gm
Coil And Duct DisinfectantAn all in one spray that disinfects all surfaces, whilst also deodorising. A blend of Deodoriser and EPA Registered Hospital Grade QUAT Disinfectant kills a wide range of pathogens and sodium hypochlorite to kill legionaella pneumophila, and most air borne pneumonia bacteria.
RealcoldStock No.
Description Pack Size Price$ Excl. GST
N0746 Greenleaf Coil & Duct Disinfectant 1L spray
N0747 Greenleaf Coil & Duct Disinfectant 5L
N0745 Greenleaf Coil & Duct Disinfectant 20L
CHEMICALSCLEANERS & DISINFECTANT
N0749
N0747
Germicidal CleanerDeodorizer and disinfect ant for ducts, coils, air filtering equipment and most other hard surfaces. Kills disease causing bacteria, as well as mould, fungi, and mildew. Helps cure bad odours, and Sick Building Syndrome reactions of sensitive people.
RealcoldStock No.
Description Pack Size Price$ Excl. GST
N0748 Greenleaf Air Filter Cleaner 1L
N0749 Greenleaf Air Filter Cleaner 5L
N0750 Greenleaf Air Filter Cleaner 20L
183Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Che
mic
als
ActabsPrevent drain pan overflow and odours. Patented dispenser avoids monthly applications. Lasts about 5 months. Actabs are placed in the drain pan.
RealcoldStock No.
Description Pack Size Price$ Excl. GST
N0703 Stewart Hall Actabs Self-dispensing pack of 6
N0704 Stewart Hall Actabs JR 400g Bottle, approx. 200 tabs
Miscellaneous ChemicalsAcid-Away®
A unique chemical treatment for use in air conditioning and refrigeration systems that have experienced a burn out or operating systems that are showing a build-up of acid content. May be used in hermetic or semi hermetic compressors that operate with standard CFC or HCFC refrigerants using mineral and alkylbenzene type refrigeration oils. Acid-Away® has been tested in accordance with ANSI/ ASHRAE standards 86-1983 and 97-1989, along with various ASTM standards.
RealcoldStock No.
Description Pack Size Price$ Excl. GST
N0800 Acid-Away® for Mineral/ Alkylbenzene Oils (not suitable for polyolester oils).
118ml bottle (4oz)
N0808 Acid-Away® for Polyolester Oils 118ml bottle (4oz)
Acid Test KitsOil should be tested immediately after removal from unit.
RealcoldStock No.
Description Pack Size Price$ Excl. GST
T0117 ETK Refrigeration Oil Acid Test Kit - Polyolester Oil 118ml bottle (4oz)
T0118 TKO Refrigeration Oil Acid Test Kit 118ml bottle (4oz)
Liquid Leak Detectors - Big Blu Leak Reactant® ™ Registered trade mark of The Rectorseal Corporation.
RealcoldStock No.
Description Pack Size Price$ Excl. GST
T0440 Big Blu leak Reactant Complete With Spray Applicator 0.947 L
T0442 Big Blue Leak Reactant 3.785 L
Visit www.rectorseal.com and www.greenleaf.co.nz for additional product information and MSDS Data Sheets.
CHEMICALSMISCELLANEOUS
Coil ProtectantDesigned to protect coils and cabinets from corrosion.
RealcoldStock No.
Description Pack Size Price$ Excl. GST
N0062 Blue Coil Guard 600ml
184Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
trol
s
Dual Pressure ControlsRealcoldStock No.
Model Description Price$ Excl. GSTReset Hp/Lp Range Differential
kPa kPa
Ranco Dual Pressure Controls
G0048 017-8711*AutoAuto
LPHP
-30 to 700700 to 3000
62 to 393 350 bar fixed
G0056 017-8701AutoAuto
LPHP
-30 to 700700 to 3000
62 to 393 345 bar fixed
G0055 017-8705AutoManual
LPHP
-30 to 700700 to 3000
62 to 393 345 bar fixed
G0203 Dual Pressure Switch Replacement Cover
G0204 Single Pressure Switch Replacement Cover
* These Ranco controls are complete with copper capillaries fitted.
Saginomiya Dual Pressure Controls
G1010 DNS-D306XM
AutoManual
LPHP
-60 to 600800 to 3000
60 to 400 Manual reset
G1015 DNS-D306XAutoAuto
LPHP
-60 to 600800 to 3000
60 to 400 400 bar fixed
G1016 DNS-D606X*AutoAuto
LPHP
-60 to 600800 to 3000
60 to 400 400 bar fixed
G1017 DNS-D606XM*
AutoManual
LPHP
-60 to 600800 to 3000
60 to 400 Manual reset
* 606 series have independent contacts for high and low side.
CONTROLSPRESSURE CONTROLS
185Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
trol
s
High Pressure ControlsRealcoldStock No.
Model Reset Range(kPa)
Differential(kPa)
Price$ Excl. GST
Ranco High Pressure
G0053 016-8750 Auto 690 to 3000 250 to 800
G0054 016-8751 Manual 690 to 3000 320 fixed
Differential Pressure ControlsRealcoldStock No.
Model Reset Range(kPa)
Differential(kPa)
Price$ Excl. GST
Saginomiya
G1019 WNS-C106X Auto 50 to 350 50 to 250
Low Pressure ControlsRealcoldStock No.
Model Description Price$ Excl. GSTReset LP Range Differential
kPa kPa
Ranco Low Pressure Controls
G0044 016-8713* Auto -30 to 700 62 to 393
G0050 016-8706 Auto -30 to 700 62 to 393
* These Ranco controls are complete with copper capillaries fitted.
Saginomiya Low Pressure Controls
G1000 SNS-C106X Auto -60 to 600 60 to 400
G1002 SNS-C102X Auto -20 to 200 25 to 150
G1006 SNS-C110X Auto 100 to 1000 100 to 300
CONTROLSPRESSURE CONTROLS
High Pressure ControlsRealcoldStock No.
Model Reset Range(kPa)
Differential(kPa)
Price$ Excl. GST
Saginomiya High Pressure
G1005 HNS-C130X Auto 800 to 3000 Fixed 400
G1008 SNS-C130X Auto 500 to 3000 300 to 1000
186Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
trol
s
Pressure Control AccessoriesRealcoldStock No.
Description Price$ Excl. GST
G0057 Ranco Angle Bracket to suit pressure controls
G0058 Shineyear Coupler (capillary and nuts) to suit pressure controls
G0060 Flica 600 mm Capillary Couplers c/w Nuts
G0062 Flica 1000 mm Capillary Couplers
Oil Protection Controls - Differential Pressure Controls (oil failure)COPD = Cut Out Pressure Differential. CIPD = Cut In Pressure Differential
RealcoldStock No.
Model Description Reset Price$ Excl. GST
Time Delay COPD (bar) CIPD (bar)
G0096 Ranco P30-3601* 60 second 0.3 to 4 0.7 to 4.8 Manual
G0097 Ranco P30-3701* 90 second 0.3 to 4 0.7 to 4.8 Manual
G0099 Ranco P30-3801* 120 second 0.3 to 4 0.7 to 4.8 Manual
* These Ranco controls are complete with copper capillaries fitted.Please refer to Frascold Accessories page for Sealed/Electronic Oil Protection Systems.
Saginomiya Flow SwitchesRealcoldStock No.
Model Description Price$ Excl. GST
G1090 FQS-U30GSuitable for pipes: 1” to 6” Connection: 1” NPT
Pressure Control HosesRealcoldStock No.
Description Price$ Excl. GST
G0070M 12" Hose 1/4" FF x 1/4" FF 90°
G0071M 18" Hose 1/4" FF x 1/4" FF 90°
G0072M 24" Hose 1/4" FF x 1/4" FF 90°
G0074M 36" Hose 1/4" FF x 1/4" FF 90°
G0075M 48" Hose 1/4" FF x 1/4" FF 90°
G0076M 60" Hose 1/4" FF x 1/4" FF 90°
• These hoses are designed for permanent installation and have a 1/4” FF metal to metal seat. Copper gaskets recommended. Suitable for capillary lines, etc.
• The minimum operating temperatures these hoses can be safely used at is -30°C, and the maximum is 122°C. Maximum pressure rating is 4000 kPa.
CONTROLSPRESSURE CONTROLS
187Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
trol
s
Pressure Controls - CB Series
• Pressure Control CB series are small disc type pressure controls featuring compact structure and proven reliability
• They are designed to suit modern designed applications with various types of connection style, applications include air conditioning, auto industries and others.
• Type ACB - High & Medium pressure range
• Type LCB - Low pressure range
Small Pressure Controls - Type ACB, LCB Conversion Factor: 1 Bar = 14.5 PSI
RealcoldStock No.
Model OFF (PSI) ON (PSI) Colour Life Cycle (Times) Price$ Excl. GST
G1160 LCB-PA48 6±5 21±7 Blue 10,000
G1162 LCB-PA95 10±5 25±5 Blue 10,000
G1164 LCB-PA96 35±7 60±7 Blue 10,000
G1168 ACB-PA53 170±14 250±14 Red 100,000
G1170 ACB-PA55 200±20 259±10 Red 100,000
G1172 ACB-PB51 410±14 335±14 Black 100,000
G1174 ACB-PB52 385±14 310±14 Red 100,000
G1176 ACB-PB111 400±14 300±21 Red 100,000
G1178 ACB-PB112M 400±28 <300 Manual Red 10,000
G1180 ACB-PB113 350±10 250±20 Red 100,000
Electrical RatingsType ACB, LCB Category Of Ratings
M Rating
Rated Voltage (V)Rated Amps. (A)
Power Factor(COS )
125V AC 250V AC
12V DC
Non-Inductive Current 1 1 to 6 1 to 4 1 to 4
InductiveCurrent
Full LoadLocked Rotor
0.750.45
1 to 24 1 to 16 —
Type ACB, LCB
: Operating direction on press.
Increase at high press.
M : Operating direction on manual reset
Contact Style Connections
Specifications
• Lead wire end: Free
• Contact action: SPST
• Ambient Temperature: -30°C to +100°C
• Fluid Temperature: -54°C to +135°C
Should mark pressure ON/OFF setting on the body• Pressure Connection: ¼” Female
• Construction: Waterproof
Dimensions
CONTROLSPRESSURE CONTROLS
188Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
trol
s
Domestic - RancoRealcoldStock No.
Type Application Normal °C Cold °C Warm °C Price$ Excl. GSTCut In Cut Out Cut Out Cut In Cut In
G0104 K50-P1125-001 Single Temp. Cabinet -9.5 — -18 — +8.5
G0110 K50-P1126-001 Freezer Cabinet -12 -18 -24 — -9.5
G0118 K50-P1127-001 Bottle Cabinet +5 — +1.5 — +12.5
G0109 VCI (K50-P1110) Single Temp. Cabinet -5 -14 -24 — +2
G0108 VF3 (K50-P1117) Freezer -18 -24 -32 — -12
G0114 VB7 (K50-P1118) Bottle Cabinet — — -3 +2 +12
G0119 VT9 (K59-L1102) Dual Temperature — — -26 +3.5 —
Commercial - RancoRealcoldStock No.
Type Range °C Differential Sensor Price$ Excl. GST
G0125 016-6950 -35 to -7 1.7 to 12°C Coiled Capillary
G0130 016-6951 -18 to +13 1.7 to 12°C Coiled Capillary
G0135 016-6954 -5 to +25 1.7 to 12°C Coiled Capillary
G0136 016-6924 -5 to +25 1.7 to 12°C Straight Capillary Tube
G0140 016-6980 -18 to +13 1.7 to 12°C Cross Ambient Bulb
G0145 016-6981 -5 to +25 1.7 to 12°C Cross Ambient Bulb
G0148 016-6983 +10 to +40 1.7 to 12°C Cross Ambient Bulb
G0178 018-1100 0° Fixed 1/8" Ice Capillary With Bulb
G0146 Flat Mounting Bracket to suit Ranco Thermostats
• Straight and coiled capillary thermostats are used on applications where it can be guaranteed that the sensing element is always cooler than the control head. Where local sensing is required, the coiled version is used, whereas the straight version is used to sense over a longer distance eg across an evaporator coil.
• Cross Ambient Thermostats have a capillary and remote bulb. Unlike the straight or coiled capillary models, these controls sense only at the bulb. They should be used on all applications where it is possible that the control head or capillary can be at a lower temperature than the sensing bulb.
Capillary - SaginomiyaRealcoldStock No.
Type Range °C Differential Sensor Price$ Excl. GST
G1052 XWS-C1030AGL2 Switches: 8 amps -35 to +30°C 2 to 7°C 2 M Capillary
G1053 XWS-C1060AGL2 Switches: 8 amps -5 to + 60°C 2 to 7°C 2 M Capillary
G1054 CNS-C114XM2 -15° to 15°C Capillary Safety Thermostat with 1m capillary. Manual Reset Fixed Differential.
G1061DTB-X178 Bottle cabinet thermostat (Skope)
Adjustable setting OFF -10°C, ON +5°C
CONTROLSTHERMOSTATS
189Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
trol
s
Saginomiya Air Conditioning ThermostatsRealcoldStock No.
Type Range °C Differential Sensor Price$ Excl. GST
G0150VRS-C234 Q147 10 to 35°C 1.5°C fixed Room
Two stage, auto changeover, knob adjustment 2°C fixed between stages
G0151VRS-C234Q149 10 to 35°C 1.5°C fixed Room
Two stage, auto changeover, screw driver adjustment 2°C fixed between stages
G0153VRS-C234 Q172 10 to 35°C 1.5°C fixed Room
Two stage with auto changeover ON/OFF Switch 2°C fixed between stages
G0155ARS-630 10 to 30°C 1.5°C fixed Room
Two stage with auto changeover and upper/lower range limiters 2°C fixed between stages
Thermostat GuardsRealcoldStock No.
Model Height Width Depth Price$ Excl. GST
G0161BTG-RK 162 mm 89 mm 76 mm
With Ring Base for easy installation on new or existing thermostats
Note: Please refer to page 192 for Defrost Controls and to page 190 for Electronic Controls
A1 Thermostat Guards are stylish, unbreakable, and tamper-proof. A single key is provided for convenience.Each guard comes with the guard, key, wall bracket, and four mounting screws and anchors. Install frame on wall, hook the guard onto the frame by means of the two hooks on top, and lock.
CONTROLSTHERMOSTATS
190Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
trol
s
Carel Electronic Controls ir33 - New Generation
Following ir32, one of CAREL’s most famous and best selling controllers, the ir33 range represents the maximum technology that CAREL offers in the field of refrigeration applications.
The top-of-the-range model characterising the new series arouses special interest as it can be fitted with all the options available: infrared remote control, programming key, repeater display, high efficiency LED display, HACCP function, real time clock, RS485 serial port, second evapora-tor defrost management, without sacrificing the 4 control relays and the 115 to 230 Vac switching power supply.
All obviously in the same dimensions as the current ir32 case!
Another unique feature concerning this new series of controllers is the possibility to manage smart defrosts, optimising the management of this function, with consequent energy savings.
Finally, one very important aspect involves the IP65 index of protection; the modern technology implemented by CAREL for the moulding of the plastic parts has allowed the protection gasket to be integrated directly into the front panel, without the need to add accessory components to the product that may create an unpleasant aesthetic and visual impact.
Refrigeration ControlsAll models are fitted with a buzzer and can be connected to the Carel Supervisory system (Plant Visor) via the RS485 interface. Please note that Temperature Sensors are not included; please choose the probe that you require from the options below.
RealcoldStock No.
Model Compressor Defrost Fan Aux Infrared Real Time Clock
Price$ Excl. GST
12/24V AC/DC Version
G4501 IR33SOLR00 16A — — — YES —
G4503 IR33COLR00 16A 8A 8A 8A YES —
230V AC Version
G4505 IR33SOER00 8A — — — YES —
G4507 IR33FOER00 8A 8A 5A — YES —
115/230V AC Version
G4509 IR33COHR00 16A 8A 8A 8A YES —
G4511 IR33COHB00 16A 8A 8A 8A YES YES
230V AC Din Rail Version RealcoldStock No.
Model Description Price$ Excl. GST
G4512 DN33SOEN00 Carel 230V DIN Rail 1 stage Tstat with static defrost and 16 A relay
G4513 DN33FOEN00 Carel 230V DIN Rail low temp controller with 3 relays
G4536 IRDRDOXIP66 Carel DIN Rail Enclosure
CONTROLSELECTRONIC CONTROLS
191Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
trol
s
Temperature SensorsRealcoldStock No.
Model Description Price$ Excl. GST
G4550 NTC015WP00 IP68 Immersion sensor 1.5m cable. Temp. range -50 - +100°C
G4552 NTC060WP00 IP67 Immersion sensor 6.0m cable. Max Temp = +100°C
AccessoriesRealcoldStock No.
Model Description Price$ Excl. GST
G4302 ABS100/75LG Standard Enclosure W/Cut-out
G4306 87-84315/ RE H95AG
Enclosure for All Panel Mount Controllers. Suitable for all standard 70 mm x 28 mm panel mount controllers.
Electronic Controllers - Fan Speed Controller - Pressure ActuatedRealcoldStock No.
Model Description Price$ Excl. GST
Single Phase Controller
G1121 Saginomiya RGE-Z1N4-5
Pressure Actuated Fan speed controllerFactory set for R22, R404A, R407C and adjustable for use with R134a.For approved motors rated from 0.2 - 4 Amps. Single phase.Capillary pressure sensorRange 8 - 28 Bar adjustable4 Bar fixed proportional band
G1123 Saginomiya RGE-Z1N6-5Pressure Actuated Fan speed controllerFactory set for R410A Refrigerant.Single Phase, 4 Amps, IP54.
G1124 Saginomiya RGE-Z1Q4-5
Pressure Actuated Fan speed controllerFactory set for R22, R404A, R407C Refrigerants adjustable for use with R134a. Single Phase, 8 Amps, IP54.
CONTROLSCONTROL PANELS
192Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
trol
s
Defrost ControlsRealcoldStock No.
Model Description Price$ Excl. GST
G0090
PARAGON 8145-21(Replaces Precision 6145-21)
• Time initiated. • Externally temperature or pressure terminated.• 1 - 6 defrosts per 24 hours.• Minimum of 4 hours between defrost.• Length of defrost 4 to 110 minutes in 2 minute
increments.• Has relay contact facility.• Suitable for 208 - 240 V 50 Hz.• Maximum contact rating is 25 Amps.
G0091PARAGON632-21*
• Time initiated, time terminated with fan delay.• 1 - 8 defrost per 24 hours.• Minimum of 3 hours between defrosts. • Pre-defrost delay 0 to 30 minutes in 3 minute
increments.• Defrost period 3 to 45 minutes in 3 minute
increments.• Post defrost delay 3 to 15 minutes in 3 minute
increments.• Suitable for 208 - 240 V 50 Hz.• Maximum contact rating is 10 Amps.
G0092
PARAGON 8045-21(Replaces Precision 6045-21)
• Time initiated, time terminated.• 1 - 6 defrosts per 24 hours.• Minimum of 4 hours between defrosts.• Length of defrost 4 - 110 minutes in 2 minute
increments.• For basic defrost systems.• Suitable for 220 - 240 V 50 Hz.• Maximum contact rating is 25 Amps.
G0093
PARAGON 8245-21(Replaces Precision 6245-21)
• Time initiated, pressure terminated.• 1 - 6 defrosts per 24 hours.• Minimum of 4 hours between defrosts.• Length of defrost 4 to 110 minutes in 2 minute
increments.• Adjustable cut-in setting dial calibrated from 36-110
psi• (248 - 758 kPa) for R12, R22, R502.• Suitable for 208 - 240 V 50 Hz.• Maximum contact rating is 40 Amps.
G0084FRIGO FLASH 16022*
• Compact Series 72 mm x 72 mm• 24 hour clock• Supply voltage 220 / 240 V +10% - 15% 50 / 60 Hz• Operating Temperature: -10°C/ +50°C• 10 minute programming segments• 72 switchings per day• Minimum interval between 2 switchings: 20 minutes• Contact ratings: 16 Amp resistive, 3 Amp inductive
* NB: External relay may be required in some applications.
CONTROLSDEFROST CONTROLS
193Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Con
trol
s
Defrost Safety ThermostatsRealcoldStock No.
Model Description Price$ Excl. GST
G0014 ML55 Thermostat 10 Amps Open +13°C Close +2°C
G0016 ML70 Thermostat 10 Amps Open +21°C Close +10°C
G0020 GL243 Surface Mount Clip (3 per Pack)
G0022 GL249 Tube Mount Clip 3/8 - 1/2 - 5/8 (2 per Pack)
Defrost Heat TapeRealcoldStock No.
Model Description Price$ Excl. GST
N0626 FST25Jimi Heat Self Regulating Tape 26W/M at 10°C - 240 VACMinimum installation temperature -40°C
N0635 Seal Kit FCT BTV-2
N0626 can be used in evaporator drains, provided correct termination kits are fitted.
Condensate PansThe MA-Line condensate evaporator pan eliminates floor drains. The unit is made of die-cast aluminium and the resulting hard, bright surface give the pan unequalled efficiency and trouble free operation. The pan is self standing. All terminal connections are covered with moisture proof rubber. Evaporation rate is 250ml per hour at 22.2°C room temperature. The unit’s heating element is sealed in ¼” Bundy weld tubing.
RealcoldStock No.
Description Voltage Watts Dimensions (mm) Price$ Excl. GSTL W H
C4080 MA-Line Condensate Pan - Small 240V 160 260 103 60
C4082 MA-Line Condensate Pan - Large 240V 160 260 121 75
CONTROLSDEFROST CONTROLS & ACCESSORIES
194Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Tool
s &
Test
Equ
ipm
ent
Service Manifold SetsMastercool introduces the most advanced and user friendly Digital Manifold on the market today. This manifold offers a large, easy to read LCD that displays Pressures, Saturated Temperatures, Actual Temperatures, Superheat and Subcooling Temperatures for over 60 refrigerants. When used with the clamp-on thermocouple connector, it will display the actual temperature and automatically calculate the superheat or subcool temperature. When the vacuum sensor cable is attached to the manifold it will display deep vacuum. To insure lasting performance and durability the manifold case is constructed of ABS material and protected by a rugged rubber boot.The technician now has a fully functional manifold with the intelligence to quickly access and deliver the accurate information needed to do the job right.
RealcoldStock No.
Model Description Gauges / Hoses Scale Price$ Excl. GST
Aluminium 4-Way Manifold Gauge Sets
T4110M 96203-MB 4W Ball Valve Manifold (80 mm)
R22, R134a, R404A, R407A, R507A
bar & psi, °C
T4111M 96203-EB 4W Ball Valve Manifold (80 mm)
R22, R407C, R410A bar & psi, °C
Full 3/8” bore through the block increases; flow considerably, faster charging & recovery. Ball valve rotates 90° between two teflon washers requiring little efwfort to turn, even under pressure. Opens and closes quickly with only a quarter turn. Knob position shows whether valves are open or closed.
2-Way Aluminium Manifold Piston Valve
T2182M 93103-E 2W Aluminium Manifold R22, R404A, R410A bar & psi, °C
Mastercool’s 2-Way Manifolds feature free floating piston valve design resulting in less wear and tear in com-parison to market standard twisting piston valves. Double O-Ring allows for a much better seal resulting in less leaks.
2-Way Digital Manifold
T2191M 99661 Digital 2W manifold + thermocouple, 3-150 cm
R22, R134a, R404A, R410A
bar & psi, °C, °F, Mpa, Kg/cm²
Complete Kit in a blow molded case includes: manifold with a set of 3-150 cm hoses, vacuum sensor with cable and clamp-on thermocouple.
4-Way Digital Manifold
T4220M 99972 Digital 4W Manifold + thermocouples, 3-180 cm
R22, R134a, R404A, R410A
bar & psi, °C, °F, Mpa, Kg/cm²
T2192M 99961-EU Digital 4 Way Manifold, complete set, 3-150 cm
R22, R134a, R404A, R410A
bar & psi, °C, °F, Mpa, Kg/cm2
Complete Kit in a blow molded case includes: manifold with a set of 3-150 cm (3-180 cm) ball valve hoses with manual shut-off valves and one black vacuum hose, vacuum sensor with cable, clamp-on thermocouple, data logger CD and USB cable.
TOOLS & TEST EQUIPMENTMANIFOLD SETS
195Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Tool
s &
Test
Equ
ipm
ent
Charging hoses suitable for all CFCs, HCFCs, HFCs & R410AMastercool uses only GRADE 5 HOSE with a selection of Standard and Nylon Barrier for high pressure applications. Knurled brass nuts make finger tightening easy. Crimped with 8 segment dies for secure fit and maximum durability. Hoses are available in sets and a variety of lengths to meet all EPA, SAE and UL requirements for containment of refrigerant.
RealcoldStock No.
Model Fittings Length Colour Price$ Excl. GST
80 mm Standard Hoses
T2240M 47363
1/4” Charging Hoses 90 cm
Red
T2242M 47361 Blue
T2244M 47362 Yellow
T2246M 476031/4” Charging Hoses 150 cm
Red
T2248M 47601 Blue
T2250M 47722
1/4” Charging Hoses 180 cm
Yellow
T2252M 47723 Red
T2254M 47721 Blue
T2280M 46372 1/4” Hoses Set - W/Automatic Shut Off 180 cm Set of 3
T2310M 49363-JT1/4” x 5/16” Charging Hoses 90 cm
Red
T2311M 49361-JT Blue
T2275M 49603-J-T 5/16” Charging Hose 150 cm Red
TOOLS & TEST EQUIPMENTCHARGING HOSES
Vacuum HosesRealcoldStock No.
Model Fittings Length Colour Price$ Excl. GST
T2262M 94136
3/8” Vacuum Hose
90 cm Black
T2259M 94160 150 cm Black
T2266M 94172 180 cm Black
Hose GasketRealcoldStock No.
Model Description Price$ Excl. GST
T0072 MR517 Gasket to suit 1/4" hoses (not suitable for 410a)
T2601M OGB79583 Core depressor
T2602 19011 Gasket to suit 3/8" hose
T2603 19034 Gasket for 14 mm Coupler Adapter (refer J0744 on page 159)
T0756 CH-79583 Hose gasket set with 3 gaskets and a core depressor
Manual Shut-Off Ball ValvesRealcoldStock No.
Model Description Price$ Excl. GST
T4303M 90430 1/4” x 1/4” Swivel Ball Valve only
T4304M 90433 1/4” x 5/16” Swivel Ball Valve only
196Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Tool
s &
Test
Equ
ipm
ent
GaugesRealcoldStock No.
Model Description Suitable for Refrigerants
Scale Price$ Excl. GST
80 mm Standard Gauge
T2217M EBH High Pressure Gauge (80 mm) R22, R407C, R410A bar & psi, °C
T2218M MRBH High Pressure Gauge (80 mm) R22, R134a, R404A bar & psi, °C
T2219M MRBL Low Pressure Gauge (80 mm) R22, R134a, R404A bar & psi, °C
T2229M EBL Low Pressure Gauge (80 mm) R22, R407C, R410A bar & psi, °C
63 mm Standard Gauge
T2220M EH High Pressure Gauge (63 mm) R22, R410A, R507, R404A bar & psi, °C
T2222M MRH High Pressure Gauge (63 mm) R22, R134a, R404A bar & psi, °C
T2210M MRL Low Pressure Gauge (63 mm) R22, R134a, R404A bar & psi, °C
Accessories
T2233M 91553-E Gauge Protection Set (80 mm)
T2234M 93553-E Gauge Protection Set (63 mm)
T2235M 85253-E Replacement Lens for GGE (63 mm)
T2236M 98251-E Replacement Lens for GGE (80 mm)
TOOLS & TEST EQUIPMENTGAUGES
197Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Tool
s &
Test
Equ
ipm
ent
CouplersRealcoldStock No.
Model Description Price$ Excl. GST
Airconditioning (R410A) Couplers
T2711M 90413 R410A Adapter - 5/16” FF x 1/4” MF
T2712M 90366 R410A Adapter - 1/4” FF x 5/16” MF
Automotive (R134a) Couplers
T2307M 82834-E Service coupler HS R134a manual 1/4” FL-M x 16 mm
T2308M 82934-E Service coupler LS R134a manual 1/4” FL-M x 13 mm
Access Port Core Remover
T2290M 91496 Valve core access tool w/access port
T4050M 91490 Standard Valve Core Remover/Installer 1/4”
T4060M 91498 Valve core remover/installer, incl. for R410A
Imperial Kwik - Couplers
T0092 16C Kwik-Coupler Model 16C Straight Coupler (45° Flare 1/4” Female x 1/4” Male)
T0093 15140 Kwik-Coupler Model 17C 90° Coupler (45° Flare 1/4” Female x 1/4” Male)
T0093A 65155 & 65153 Gasket Set for above Kwik-Couplers
T0095 26C Kwik-Couplers Straight 5/16”
T0097 27C Kwik-Couplers 90° Coupler 5/16”
TOOLS & TEST EQUIPMENTCOUPLERS
198Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Tool
s &
Test
Equ
ipm
ent
Mastercool ToolsRealcoldStock No.
Model Description Price$ Excl. GST
Tube Cutters
T4025M 70027 Mini tube cutter for 1/8” to 5/8” OD tubing
T2011M 72029 Mini tube cutter for 3/8” to 1 1/8” OD tubing
T4021M 72035 Heavy duty tube cutter 1/8 to 1 1/8” OD tubes
T2008M 70038 Heavy duty tube cutter 1 1/4 to 3” OD tubing
Cutter Wheels
T4022M 70028 Cutting wheels for 70027
T4023M 72030 Cutting wheels for 70029
T4024M 72034 Cutting wheels for 70035
T4026M 70138 Cutting wheels for 70038
Tube Deburring Tool
T2089M 71685 Pencil type reamer - metal
T1030 MA-49310 Pencil reamer
Tube Expander Kit
T2035M 71600 Hydra-swage tube expander kit - 7 heads 3/8” - 1 1/8”
Tube Benders Mechanical
T2070M 70070 Tube benders kit
Ratchet Wrenches
T2046M 70082 Refrigeration ratchet wrench 1/4”, 3/8”, 3/16”, 5/16” sq
T2049M 70081 Ratchet wrench 9/16”, 1/2” hex
Flaring & Swaging Tools
T0742 CH-806A Flaring Tool 1/4” to 3/4” OD
T2024M 70052 Flaring tool 3/16” to 5/8”
T4000M 70048 Set of 5 swaging punches
T4010M 70053 Flaring and swaging kit (275) 1/8” to 3/4”
T2038M 71600-11 Expander head 1 3/8”
T2039M 71600-13 Expander head 1 5/8”
T2037M 71600-17 Expander head 2 1/8”
TOOLS & TEST EQUIPMENTVARIOUS TOOLS
T0742
T2011M
T2049M
T4010M
T4000M
T2035M
T2089M
T4024M
T2070M
199Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Tool
s &
Test
Equ
ipm
ent
Tube Benders (lever type) RealcoldStock No.
Model Brand Description Price$ Excl. GST
T0701 CH-364-04-1/4 Shine Year for 1/4" OD tube
T0703 CH-364-06-3/8 Shine Year for 3/8" OD tube
T0704 CH-364-08-1/2 Shine Year for 1/2" OD tube
T0705 CH-364A-10-5/8 Shine Year for 5/8" OD tube
T0706 CH-364-12-3/4 Shine Year for 3/4” OD Tube
T0710 CH-367 Shine Year for 1/4”, 5/16”, 3/8” OD tube, 11/16 radius to centre, 180° bender
Bending Springs RealcoldStock No.
Model Brand Description Price$ Excl. GST
T0001 CH-102-04 Shine Year to suit 1/4" OD tube
T0006 CH-102-05 Shine Year to suit 5/16" OD tube
T0002 CH-102-06 Shine Year to suit 3/8" OD tube
T0003 CH-102-08 Shine Year to suit 1/2" OD tube
T0004 CH-102-10 Shine Year to suit 5/8" OD tube
T0005 CH-102-12 Shine Year to suit 3/4" OD tube
TOOLS & TEST EQUIPMENTTUBE BENDERS & SPRINGS
Miscellaneous ToolsRealcoldStock No.
Model Brand Description Price$ Excl. GST
T0729 CH-42 Shine Year PVC Pipe Cutter
T2092 CH-208 Shine Year Tube Reamer
200Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Tool
s &
Test
Equ
ipm
ent
Pinch Off ToolRealcoldStock No.
Model Description Price$ Excl. GST
T0053 Shine Year CH-201 180 mm Pinch Off Pliers
Fin CombsRealcoldStock No.
Description Price$ Excl. GST
T0255 Wagner T-100 Kit Interchangeable Heads (4 thru 14 fpi)
T0256 Wagner Head (8 fins per inch) Orange
T0257 Wagner Head (12 fins per inch) Dark Green
T0258 Wagner Head (5 - 10 fins per inch) White
T0259 Wagner Head (11 fins per inch) Blue
T0791 CH-352 Stainless Steel Fin Comb
Inspection MirrorsRealcoldStock No.
Description Price$ Excl. GST
T1016 MA-Line 1.1/4” Round Mirror
T0053
T1016
T0255
TOOLS & TEST EQUIPMENTMISCELLANEOUS
Temperature ProbeRealcoldStock No.
Description Price$ Excl. GST
T2171M Clamp-on Temperature Probe. 1m
Vacuum GaugeRealcoldStock No.
Description Price$ Excl. GST
T2239 Mechanical Vacuum Gauge
201Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Tool
s &
Test
Equ
ipm
ent
Vacuum PumpsA good quality vacuum pump is an integral tool for complete A/C service. Mastercool vacuum pumps are durable and time tested. They stand up to the most grueling conditions and will provide years of reliable service. Mastercool offers a complete selection of pumps. Regardless of your service requirements, Mastercool has a model for your application.
RealcoldStock No.
Model Description Price$ Excl. GST
T4240M 90060-220-AUS Vacuum pump 35 Ltr/min, 2 stages
T2400M 90065-220 Vacuum pump 119 Ltr/min, 2 stages
T2402M 90067-220 Vacuum Pump 178 Ltr/min, 2 stages
Specifications T4240M T2400M T2402M
Free Air Displacement 35 Lit/min 119 Lit/min 178 Lit/min
Number of Stages 2 stages
Ultimate Vacuum 25 Microns 25 Microns 25 Microns
Intake 1/4” SAE & 1/2” ACME
Motor 1/6 Hp, 2850 RPM 1/3 Hp, 1425 RPM 1/2 Hp, 1425 RPM
Oil Capacity 295 ml 531 ml 708 ml
Dimensions 29.5 x 11.5 x 21.5 x 18 cm 37 x 15.5 x 27.5 x 24 cm 41 x 15.5 x 27.5 x 24 cm
Nett Weight 5.40 Kg 15.0 Kg 15.40 Kg
TOOLS & TEST EQUIPMENTVACUUM PUMPS
202Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Tool
s &
Test
Equ
ipm
ent
Recovery SystemMastercool introduces its newest addition to the recovery machine lineup. Taking the reliability of the 69000 series machines, Mastercool has enhanced those features to allow for maximum recovery capacity while at the same time decreasing size and weight. The design of the new double piston compressor and cooling by the largest fan and condenser in the market makes the new 69300 series the most complete solution to your recovery needs.
RealcoldStock No.
Model Description Price$ Excl. GST
T2380M 69300-220 TWIN TURBO Refrigerant Recovery Unit 220V-50/60 Hz
Specifications Recovery Rate Operating Temperature Weight Dimensions in mm
1/2 Hp oil less compressor
Direct vapour up to 0.39 Kg/min (17 Kg/h)
0 to 50 °C 11 Kg 457 (L) x 254 (W) x 356 (H)Direct liquid up to 3.1 Kg/min (206 Kg/h)
Push pull up to 8.1 Kg/min (498 Kg/h)
Recovery CylindersRealcoldStock No.
Model Description Price$ Excl. GST
T2490M 62010 12,5 L recovery cylinder tank
T2491M 63010 27,2 L recovery cylinder tank
TOOLS & TEST EQUIPMENTRECOVERY UNITS
T2491MT2490M
203Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Tool
s &
Test
Equ
ipm
ent
Testing EquipmentRealcoldStock No.
Model Description Price$ Excl. GST
Temperature Test Equipment
T1314 MA-DMT123Dual Probe ThermometerExtra wide Temperature range from (-200°C to 1370°C) with high accuracy
T1328 MA-RT900Hand Held Digital ThermometerWide Measurement range (-50°C to 200°C), never needs to be calibrated
T1332 MA-12843 Digital Anemometer
T1349 MA-600CF Auto ranging ECO clampon meter
Refractometers
T1032 MA-REF401C
Glycol RefractometerPrecision optical instrument designed to measure the freezing point of ethylene or propylene based cooling systems. The two Celsius non-liner scales cover -50°C to 0°C for ethylene glycol and propylene glycol. The resolution of the temperature scale is 0°C
T1033 MA-REF700
Oil RefractometerEasy to use handheld instrument designed to accurately measure the mineral oil in polyolester (POE) lubricant during change of refrigerants
MA-DMT123
MA-RT900
MA-REF700
ThermometersArthermo -40°C/+40°C dial thermometers are housed in a heavy duty nylon case with provision for bottom or back entry capillary. Can be flush or surface mounted. Can be calibrated.
RealcoldStock No.
Model Description Price$ Excl. GST
Dial Thermometers
U0080 Realcold 60 mm dial (3000 mm capillary)
U0082 Realcold 80 mm dial (3000 mm capillary)
U0084 Realcold 100 mm dial (3000 mm capillary)
U0091 Realcold 100 mm dial (6000 mm capillary)
Cabinet Thermometers. Thermometers have provision for recalibration
U0147 ArthermoType 540 -40°C /+40°C 64.5 mm dialS/S case, with foot for standing & hook for hanging.
U0148 ArthermoType 519B -40°C /+40°C 64.5 mm dialAcrylic resin case, with hook for hanging.
TOOLS & TEST EQUIPMENTMISCELLANEOUS
Miscellaneous Testing EquipmentRealcoldStock No.
Model Description Price$ Excl. GST
T1350 MA-DMTK K-Temp probe
T1347 MA-12355 Pipe clamp temp lead
204Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Tool
s &
Test
Equ
ipm
ent
Other Test Equipment Digitial Vacuum Gauge is packaged in blow molded case. It is a hand held unit that uses thermocouple technology. This vacuum gauge has been designed with the technician’s field environment in mind, allowing for self-calibration and a sensor that will not be damaged by small mists of oil. This unit allows for a target vacuum range (20,000 to 1 micron) to be programmed with a light sensor indicator. Now you have the freedom to continue with your other work and come back to the system once you see the indicator light signaling your target vacuum.
RealcoldStock No.
Model Description Price$ Excl. GST
Electronic Vacuum Gauge
T2435M 98061 Electronic thermocouple vacuum gauge
Charging Equipment
T2370M 98211-A Accu-Charge II - Charging Scale, programmable
T2371M 98315 Wireless Charging Scale with Solenoid
T2100M 98230 Charging Solenoid Module
Leak Detectors
T2323M 55500-220 Heated UV sensor electronic leak detector w/220V battery charger
T2326M 55500-SEN Sensor for 55500
T4210M — Electronic leak detector
TOOLS & TEST EQUIPMENTTESTING EQUIPMENT & GASKET SETS
T2323M
T2370M
T2435M
Temprecord Data LoggersRealcoldStock No.
Description Price$ Excl. GST
U0320 Multi-Trip Use Data Logger
U0324 Multi-Trip Use Low Temperature Data Logger
U0339 Relative Humidity Logger
U0341 Usb Reader Interface U0339
U0341
205Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Tool
s &
Test
Equ
ipm
ent
Ritchie - Yellow Jacket SparesRealcoldStock No.
Model Description To Suit Price$ Excl. GST
Manifold Parts
T2609 19015 Gasket T2206 CH-80
T2610 41103 3/8" Piston 48584
T2611 41043 Titan Piston Assembly 49833, 49869
T2612 41133 1/4" Piston 41382, 42010
T2614 41134 Feed Screw 41382, 48584
T2615 41056 Titan/Bantam Feed Screw 49833, 49869, 45936
T2616 41107 Retaining Nut 48584
T2617 41094 Brute II Red Handle 46140, 46160
T2619 41044 Titan Red Handle 49833, 49869
T2621 41092 Brute II Blue Handle 46140, 46160
T2623 41042 Titan Blue Handle 49833, 49869
T2624 41142 Handle Screws (Set of two) 41382, 48584
T2625 41091 Brute II Yellow Handle 46140, 46160
T2626 41041 Titan Yellow Handle 49833, 49869
T2627 41090 Handle Screws Brute II 46140, 46160
T2628 40279 Hanging Hook 41382, 48584
T2629 41048 Titan Handle Screw 49833, 49869
T2631 41096 Retaining Nut Brute II 46140, 46160
T2633 41049 Retaining Nut Titan 49833, 49869
T2632 41109 Sight Glass "O"-Ring 48584
T2634 41135 Retaining Nut 41382
T2636 41141 Handle Screw & Washer 41382
T2641 41051 Yellow Handle 45836, 45936
T2642 41052 Blue Handle 45836, 45936
T2643 41053 Piston / "O"-Ring 45836, 45936
T2644 41054 Red Handle 45836, 45936
T2645 41055 O-Rings 45836, 45936
T2646 41056 Feed Screw 45836, 45936
T2647 41057 Retaining Nut 45836, 45936
T2648 41058 Handle Screw/Washer 45836, 45936
T2650 41061 Sight Glass Assembly 45836, 45936
T2651 41131 Manifold O-Rings Series 41 42010
T2653 41134 Series 41 Valve Feed Screw 42010
T2657 41143 Series 41 Valve Assembly 42010
T2658 41047 O-Ring Sight Glass Brute II and Titan
TOOLS & TEST EQUIPMENTRITCHIE - YELLOW JACKET SPARES
206Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Tool
s &
Test
Equ
ipm
ent
Ritchie - Yellow Jacket Vacuum Pump SparesRealcoldStock No.
Model Description Price$ Excl. GST
T2451 93441 Replacement cartridge for 95 L pump
T2452 93461 Replacement cartridge for 142 L pump
T2453 93012 Crystal for Vacuum Gauge Suits Vacuum Pumps
T2454 93011 Vacuum Gauge
T2457 93403 Oil Sight Glass (fits pumps manufactured up until 1997)
T2467 93365 Oil Sight Glass (fits 95 and 142 l/m pumps (manufactured from 1998 on)
T2458 93404 Oil Case Gasket (fits 95 and 142 l/m pumps (manufactured from 1998 on)
T2459 93386 Exhaust Filter
T2460 93387 Filter Element
T2462 93047 Drive Coupling
T2464 93031 Shaft Seal
T2465 93045 Motor Capacitor
T2468 93048 Oil Cover Gasket 85-96 Suits Vacuum Pumps
T2469 93369 Oil Cover Gasket 98-05 Suits Vacuum Pumps
T2470 93146 Electric Motor 115/230V 50/60 Hz
T2471 93507 Oil Cover Gasket 05 Suits Vacuum Pumps
T2472 93368 Gas Ballast 93368 Suits Vacuum Pumps
T2473 93509 Gas Ballast 93509 Suits Vacuum Pumps
T2474 93032 O-Ring Gas Ballast 93032 Suits Vacuum Pumps
T2475 93398 O-Ring Gas Ballast 93398 Suits Vacuum Pumps
T2476 93117 Rocker Switch 93117
Swage Adapters
T2580 60444 Swage Adapter 3/16” - 3/8”
T2581 60439 Swage Adapter 1/4”
T2583 60446 Swage Adapter 1/2”
T2585 60448 Swage Adapter 3/4”
Note: Except for the cartridges, all other spares are inter-changeable.
TOOLS & TEST EQUIPMENTRITCHIE - VACUUM PUMP SPARES
Tube Cutter Spares - Yellow Jacket®
RealcoldStock No.
Model Description Price$ Excl. GST
T2502 60100 Cutter Wheel for 60101, 60102, 60103
T2504 60124 Cutter Wheel for 60139
T2506 60147 Cutter Wheel for 60146
T2516 60127 Wheel Screw for 60123 (New)
T2517 60172 Handle Screw for 60139
T2526 60079 Wheel Pin & Clip for 60101, 60102, 60103
T2528 60144 Wheel Pin & Clip for 60142
T2531 60140 Screw/Retainer for 60139
T2538 60095 Reamer Screw & Washer for 60101, 60102, 60103
207Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Tool
s &
Test
Equ
ipm
ent
Bernzomatic Self-Igniting Brazing TorchesRealcoldStock No.
Description Price$ Excl. GST
N6006
BERNZOMATIC Self-Igniting Brazing TorchA simple press of the piezo igniter gives instant flame for brazing. The high performance pressure regulator and swirl flame allows higher temperatures than conventional torches. Superior performance in cold weather.
N6010
Brazing Turbo Set 200 Excl. GasCB66 Brazing Torch Description: A light weight welding and brazing system with disposable gas cylinder’s. Each kit contains:• Metal Storage carrier• Oxygen pressure reducers with HP gauge and flash back arrestors Mapp Pro pressure reducer with LP gauge and flash back arrestors• 2 m hoses with connections• Hand piece with 160 I nozzle• 4 additional nozzles 63 – 100 – 250 – 315 I• Protective goggles• Multi-purpose spanner• Flint lighter• 2 x Welding Rod
N6050 Gas Canister (Disposable)
N6011 1L Oxygen Cylinder
Some helpful hints on using your Bernzomatic:
• NOTE - USE only IN WELL VENTILATED AREAS • DO NOT ADJUST THE FLAME SO LOW THAT THE STEEL BURNER TIP BECOMES RED HOT OR DAMAGE TO
THE TIP MAY RESULT.
Q. Why does my torch head break at the air holes?A. In order to ensure that the cylinder does not break or explode if the torch is accidentally dropped or abused, BernzOmatic torches are designed to break safely at the air holes.
Q. Why will my torch not stay lit when tipped upside down?A. When a non regulated brass torch is tipped upside down, the liquid propane in the torch works its way through the torch and blows out the flame.
Q. Why in cold weather do I only get a small flame out of my torch?A. The size of the torch flame varies with the pressure in the gas cylinder. When it is very cold there is only a small amount of gas pressure in the cylinder.
Q. Why is my torch hard to light?A. Most torches light better when the valve is just cracked open, and there is a small gas flow.
N6010 Brazing Turbo Set 200
TOOLS & TEST EQUIPMENTBRAZING TORCHES
208Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
Tool
s &
Test
Equ
ipm
ent
Brazing Alloy (Silver)RealcoldStock No.
Type Tip Colour Diameter x Length (mm)
Sold Per Price$ Excl. GST
N0525 5% SBA Silver 2.5 x 750 Per Kilo
N0525A 5% SBA Silver 2.5 x 750 Per Stick
N1515 15% SBA Tan 1.5 x 750 Per Kilo
N1515A 15% SBA Tan 1.5 x 750 Per Stick
N1525 15% SBA Tan 2.5 x 750 Per Kilo
N1525A 15% SBA Tan 2.5 x 750 Per Stick
N1530 15% SBA Tan 3.0 x 750 Per Kilo
N1530A 15% SBA Tan 3.0 x 750 Per Stick
N3415 34% SBA Green 1.5 x 750 Per Kilo
N3415A 34% SBA Green 1.5 x 750 Per Stick
N5515 55% SBA Dark Green 1.5 x 750 Per Kilo
N5515A 55% SBA Dark Green 1.5 x 750 Per Stick
N5530 55% SBA Dark Green 3.0 x 750 Per Kilo
N5530A 55% SBA Dark Green 3.0 x 750 Per Stick
N5020 General Purpose Flux for Silver Brazing Alloy 250gm Pot
• 5% Silver (Silver Tip) Suitable for copper to copper and copper alloys. No flux required for copper to copper. Use flux for copper alloys. Cadmium free.
• 15% Silver (Tan Tip) Suitable for copper to copper and copper alloys, giving excellent ductility for high stressed joints. No flux required for copper to copper. Use flux for copper alloys. Cadmium free.
• 34% Silver (Green) GP alloy for general engineering metals giving excellent fluidity with excellent gap filling qualities. Flux should be used. Cadmium free.
• 55% Silver (Dark Green Tip) Excellent alloy, giving high strength with excellent capillary action. Good ability to fill fine gaps. Cadmium free.
• Realcold recomend the use of General Purpose Flux, N5020, when brazing non-ferrous metals.
Brazing AccessoriesRealcoldStock No.
Description Sold Per Price$ Excl. GST
T0119 La-Co Heat Seal Stick each
N5022 La-Co Aluminium Repair Kit Complete with flux paste, (for easy soldering of aluminium to copper). Kit
N0003 MA-Line Sand Cloth 1.1/2” 9 metre
N0005 MA-Line Sand Cloth 1.1/2” 22 metre
N0007 MA-Line Mesh Cloth 1.1/2” 45 metre
N0009 MA-Line Open Mesh Cloth 1.1/2” 9 metre
N0010 Emery Tape 80 grit 50 metre Roll
N0015 Emery Tape 180 grit 50 metre Roll
N5022
N0010
TOOLS & TEST EQUIPMENTBRAZING
T0119
209Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
PP-R
Pip
e Sy
stem
sPP-R PIPE SYSTEMS
BÄNNINGER INTRODUCTION
Bänninger Plastic Pressure Pipes & Fittings
Bänninger is a German manufacturer of plastic pressure pipes and fittings which are used in applications worldwide. Their philosophy: Modernity, dynamics and innovation - always aiming to meet the market requirements and being prepared for future developments. Bänninger’s products are made from pure raw material to ensure perfect installation every time. Their pipes and fittings have been tested and certified and are thus highly sought after worldwide and meet the audited requirements according to DIN EN ISO 9001, ISO 15874:2008, registered under certificate number 2113/12.N to d 500.
About the BR Dynatherm System
The Dynatherm PP-RCT system is suitable for a number of different applications including:
• Potable hot and cold water supply systems up to 80°C, with temperature spikes of up to 110°C
(Subject to pressure / lifetime limitations)
• Plumbing services, Mechanical services, Chilled and Condenser water reticulation
• Industrial liquids and gasses
• Building and district heating
• Geothermal
• General pressure applications up to 20 Bar (290 PSI) at 20°C
• 10 year manufacturer warranty
210Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
PP-R
Pip
e Sy
stem
s
PP-R PIPE SYSTEMSPP-RCT PRESSURE PIPE
PP-RCT Solid Wall - PN16 (Potable Cold) (4 metre lengths)Realcold Stock No.
Model Outside Dia (mm)
Inside Dia (mm)
Wall Thickness (mm)
SDR* Price$ Excl. GST
PP11000** D130.016 16.0 10.6 2.7 6
PP11001 D125.020 20.0 15.4 2.3 9
PP11002 D125.025 25.0 19.4 2.8 9
PP11003 D125.032 32.0 26.2 2.9 11
PP11004 D125.040 40.0 32.6 3.7 11
PP11005 D125.050 50.0 40.8 4.6 11
PP11006 D125.063 63.0 51.4 5.8 11
PP11007 D125.075 75.0 61.4 6.8 11
PP11008 D125.090 90.0 73.6 8.2 11
PP11009 D125.110 110.0 90.0 10.0 11
PP11010 D125.125 125.0 102.2 11.4 11
PP11011 D125.160 160.0 130.8 14.6 11
PP11012 D125.180 180.0 147.2 16.4 11
PP11013 D125.200 200.0 163.6 18.2 11
PP11014 D125.225 225.0 184.0 20.5 11
PP11015 D125.315 315.0 257.7 28.6 11
* Standard Dimension Ratio - the ratio of outer diameter to wall thickness** Note PP11000 is PPR
PP-RCT Stabi Pipe - PN20 (Indent) (4 metre lengths)Realcold Stock No.
Model Outside Dia (mm)
Inside Dia (mm)
Wall Thickness (mm)
SDR Price$ Excl. GST
PP11030 D140.016 16.0 11.6 2.2 7
PP11031 D140.020 20.0 14.4 2.8 7
PP11032 D140.025 25.0 19.4 2.8 9
PP11033 D140.032 32.0 24.8 3.6 9
PP11034 D140.040 40.0 31.0 4.5 9
PP11035 D140.050 50.0 38.8 5.6 9
PP11036 D140.063 63.0 48.8 7.1 9
PP11037 D140.075 75.0 58.2 8.4 9
PP11038 D140.090 90.0 69.8 10.1 9
PP11039 D140.110 110.0 85.4 12.3 9
PP11040 D140.125 125.0 97.0 14.0 9
211Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
PP-R
Pip
e Sy
stem
sPP-R PIPE SYSTEMS
PP-RCT PRESSURE PIPE
PP-RCT ‘Climatec’ Faser Pipe - PN16 (Potable Hot) (4 metre lengths)Realcold Stock No.
Model Outside Dia (mm)
Inside Dia (mm)
Wall Thickness (mm)
SDR Price$ Excl. GST
PP11060 D111.020 20.0 14.4 2.8 7.4
PP11061 D111.025 25.0 18.0 3.5 7.4
PP11062 D111.032 32.0 24.8 3.6 9
PP11063 D111.040 40.0 32.6 3.7 11
PP11064 D111.050 50.0 40.8 4.6 11
PP11065 D111.063 63.0 51.4 5.8 11
PP11066 D111.075 75.0 61.4 6.8 11
PP11067 D111.090 90.0 73.6 8.2 11
PP11068 D111.110 110.0 90.0 10.0 11
PP11069 D111.125 125.0 102.2 11.4 11
PP-RCT ‘Climatec’ Large Bore Faser Pipe - PN10 (4 metre lengths)Realcold Stock No.
Model Outside Dia (mm)
Inside Dia (mm)
Wall Thickness (mm)
SDR Price$ Excl. GST
PP11080 D117.160 160.0 141.0 9.5 17
PP11081 D117.180 180.0 158.6 10.7 17
PP11082 D117.200 200.0 176.2 11.9 17
PP11083 D117.225 225.0 198.2 13.4 17
PP11084 D117.250 250.0 220.4 14.8 17
PP-RCT ‘Watertec’ Large Bore Faser Pipe - PN16 (Potable Hot) (4 metre lengths)Realcold Stock No.
Model Outside Dia (mm)
Inside Dia (mm)
Wall Thickness (mm)
SDR Price$ Excl. GST
PP11100 D105.160 160.0 130.8 14.6 11
PP11101 D105.180 180.0 147.2 16.4 11
PP11102 D105.200 200.0 163.6 18.2 11
PP11103 D105.225 225.0 184.0 20.5 11
PP11104 D105.250 250.0 204.6 22.7 11
PP11105 D105.315 315.0 257.7 28.6 11
PP-RCT ‘Ecotec’ Lilac Non Potable Water Pipe - PN16 (4 metre lengths)Realcold Stock No.
Model Outside Dia (mm)
Inside Dia (mm)
Wall Thickness (mm)
SDR Price$ Excl. GST
PP11120 D127.020 20.0 15.6 2.3 9
PP11121 D127.025 25.0 19.4 2.8 9
PP11122 D127.032 32.0 26.2 2.9 11
PP11123 D127.040 40.0 32.7 3.7 11
PP11124 D127.050 50.0 40.9 4.6 11
PP11125 D127.063 63.0 51.5 5.8 11
PP11126 D127.075 75.0 61.4 6.8 11
PP11127 D127.090 90.0 73.6 8.2 11
PP11128 D127.110 110.0 90.0 10.0 11
212Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
PP-R
Pip
e Sy
stem
s
PP-R PIPE SYSTEMSPP-R FITTINGS
PP-R Long Radius Bend 90°Realcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP11140 D211.0016 16.0
PP11141 D211.0020 20.0
PP11142 D211.0025 25.0
PP11143 D211.0032 32.0
PP11144 D211.0040 40.0
PP-R Elbow M&F 45°Realcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP11195 D233.0020 20.0
PP11196 D233.0025 25.0
PP11197 D233.0032 32.0
PP-R Elbow 45°Realcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP11248 D230.0016 16.0
PP11249 D230.0020 20.0
PP11250 D230.0025 25.0
PP11251 D230.0032 32.0
PP11252 D230.0040 40.0
PP11253 D230.0050 50.0
PP11254 D230.0063 63.0
PP11255 D230.0075 75.0
PP11256 D230.0090 90.0
PP11257 D230.0110 110.0
PP11258 D230.0125 125.0
PP-R Elbow 90°Realcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP11365 D210.0016 16.0
PP11366 D210.0020 20.0
PP11367 D210.0025 25.0
PP11368 D210.0032 32.0
PP11369 D210.0040 40.0
PP11370 D210.0050 50.0
PP11371 D210.0063 63.0
PP11372 D210.0075 75.0
PP11373 D210.0090 90.0
PP11374 D210.0110 110.0
PP11375 D210.0125 125.0
PP-R Elbow M&F 90°Realcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP11482 D214.0016 16.0
PP11483 D214.0020 20.0
PP11484 D214.0025 25.0
PP11485 D214.0032 32.0
PP-R Tee 90°Realcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP11536 D240.0016 16.0
PP11537 D240.0020 20.0
PP11538 D240.0025 25.0
PP11539 D240.0032 32.0
PP11540 D240.0040 40.0
PP11541 D240.0050 50.0
PP11542 D240.0063 63.0
PP11543 D240.0075 75.0
PP11544 D240.0090 90.0
PP11545 D240.0110 110.0
PP11546 D240.0125 125.0
213Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
PP-R
Pip
e Sy
stem
sPP-R PIPE SYSTEMS
PP-RCT FITTINGS
PP-RCT Spigot Elbow 45°Realcold Stock No.
Model Suit Pipe (mm) Wall Thickness (mm)
SDR Price$ Excl. GST
PP11309 D231.0160 160.0 14.6 11
PP11310 D231.0180 180.0 16.4 11
PP11311 D231.0200 200.0 18.2 11
PP11312 D231.0225 225.0 20.5 11
PP11313 D231.0250 250.0 22.7 11
PP11314 D231.0315 315.0 28.6 11
PP-RCT Spigot Elbow 90°Realcold Stock No.
Model Suit Pipe (mm) Wall Thickness (mm)
SDR Price$ Excl. GST
PP11426 D212.0160 160.0 14.6 11
PP11427 D212.0180 180.0 16.4 11
PP11428 D212.0200 200.0 18.2 11
PP11429 D212.0225 225.0 20.5 11
PP11430 D212.0250 250.0 22.7 11
PP11431 D212.0315 315.0 28.6 11
PP-RCT Spigot Tee 90°Realcold Stock No.
Model Suit Pipe (mm) Wall Thickness (mm)
SDR Price$ Excl. GST
PP11597 D242.0160 160.0 14.6 11
PP11598 D242.0180 180.0 16.4 11
PP11599 D242.0200 200.0 18.2 11
PP11600 D242.0225 225.0 20.5 11
PP11601 D242.0250 250.0 22.7 11
PP11602 D242.0315 315.0 28.6 11
214Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
PP-R
Pip
e Sy
stem
s
PP-R PIPE SYSTEMSPP-R / PP-RCT FITTINGS
PP-R Reducing Tee (inlet x branch x outlet)Realcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP11653 D241.201620 20x16x20
PP11654 D241.202520 20x25x20
PP11655 D241.251625 25x16x25
PP11656 D241.252020 25x20x20
PP11657 D241.252025 25x20x25
PP11658 D241.252520 25x25x20
PP11659 D241.322020 32x20x20
PP11660 D241.322025 32x20x25
PP11661 D241.322520 32x25x20
PP11662 D241.322032 32x20x32
PP11663 D241.322532 32x25x32
PP11664 D241.402040 40x20x40
PP11665 D241.402540 40x25x40
PP11666 D241.403232 40x32x32
PP11667 D241.403240 40x32x40
PP11668 D241.502050 50x20x50
PP11669 D241.502550 50x25x50
PP11670 D241.503250 50x32x50
PP11671 D241.504050 50x40x50
PP11672 D241.632063 63x20x63
PP11673 D241.632563 63x25x63
PP11674 D241.633263 63x32x63
PP11675 D241.634050 63x40x50
PP11676 D241.634063 63x40x63
PP11677 D241.635063 63x50x63
Realcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP11678 D241.752075 75x20x75
PP11679 D241.752575 75x25x75
PP11680 D241.753275 75x32x75
PP11681 D241.754075 75x40x75
PP11682 D241.755075 75x50x75
PP11683 D241.756375 75x63x75
PP11684 D241.906390 90x63x90
PP11685 D241.907590 90x75x90
PP11686 D241.110063 110x63x110
PP11687 D241.110075 110x75x110
PP11688 D241.110090 110x90x110
PP11689 D241.125075 125x75x125
PP11690 D241.125090 125x90x125
PP11691 D241.125110 125x110x125
PP-RCT Spigot Red Tee (inlet x branch x outlet)Realcold Stock No.
Model Suit Pipe (mm) Wall Thickness (mm)
SDR Price$ Excl. GST
PP11792 D244.160090 160 x 90 x 160 14.6 x 8.2 x 14.6 11
PP11793 D244.160110 160 x 110 x 160 14.6 x 10.0 x 14.6 11
PP11794 D244.225110 225 x 110 x 225 20.5 x 10.0 x 20.5 11
PP11795 D244.225125 225 x 125 x 225 20.5 x 11.4 x 20.5 11
PP11796 D244.225160 225 x 160 x 225 20.5 x 14.6 x 20.5 11
215Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
PP-R
Pip
e Sy
stem
sPP-R PIPE SYSTEMS
PP-R FITTINGS
PP-R Tee 45°Realcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP11847 D260.0032 32.0
PP11848 D260.0040 40.0
PP11849 D260.0050 50.0
PP11850 D260.0063 63.0
PP-R CrossRealcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP11901 D261.0032 32.0
PP11902 D261.0040 40.0
PP11903 D261.0050 50.0
PP11904 D261.0063 63.0
PP-R Manifold Distributor PipeRealcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP11955 D263.2516 25 x 16
PP11956 D263.3220 32 x 20
PP11957 D263.3225 32 x 25
PP11958 D263.4025 40 x 25
PP-R Reducer M&FRealcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP12113 D206.002016 20 x 16
PP12114 D206.002516 25 x 16
PP12115 D206.002520 25 x 20
PP12116 D206.003220 32 x 20
PP12117 D206.003225 32 x 25
PP12118 D206.004020 40 x 20
PP12119 D206.004025 40 x 25
PP12120 D206.004032 40 x 32
PP12121 D206.005020 50 x 20
PP12122 D206.005025 50 x 25
PP12123 D206.005032 50 x 32
PP12124 D206.005040 50 x 40
PP12125 D206.006320 63 x 20
PP12126 D206.006325 63 x 25
PP12127 D206.006332 63 x 32
PP12128 D206.006340 63 x 40
PP12129 D206.006350 63 x 50
PP12130 D206.007550 75 x 50
PP12131 D206.007563 75 x 63
PP12132 D206.009063 90 x 63
PP12133 D206.009075 90 x 75
PP12134 D206.110063 110 x 63
PP12135 D206.110075 110 x 75
PP12136 D206.110090 110 x 90PP-R Manifold Distributor Pipe Female Thread BSP OutletsRealcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP12009 D264.3215 32 x 1/2”
PP12010 D264.4015 40 x 1/2”
PP-R Manifold Distributor Pipe Male Thread BSP OutletsRealcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP12061 D265.3215 32 x 1/2”
PP12062 D265.4015 40 x 1/2”
PP-R SocketRealcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP12296 D201.0016 16.0
PP12297 D201.0020 20.0
PP12298 D201.0025 25.0
PP12299 D201.0032 32.0
PP12300 D201.0040 40.0
PP12301 D201.0050 50.0
PP12302 D201.0063 63.0
PP12303 D201.0075 75.0
PP12304 D201.0090 90.0
PP12305 D201.0110 110.0
PP12306 D201.0125 125.0
216Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
PP-R
Pip
e Sy
stem
s
PP-R PIPE SYSTEMSPP-R / PP-RCT FITTINGS
PP-RCT Spigot ReducerRealcold Stock No.
Model Suit Pipe (mm) Wall Thickness (mm)
SDR Price$ Excl. GST
PP12237 D207.125110 125 x 110 11.4 x 10.0 11
PP12238 D207.160110 160 x 110 14.6 x 10.0 11
PP12239 D207.160125 160 x 125 14.6 x 11.4 11
PP12240 D207.180160 180 x 160 16.4 x 14.6 11
PP12241 D207.200125 200 x 125 18.2 x 11.4 11
PP12242 D207.200160 200 x 160 18.2 x 14.6 11
PP12243 D207.225160 225 x 160 20.5 x 14.6 11
PP12244 D207.250160 250 x 160 22.7 x 14.6 11
PP12245 D207.315250 315 x 250 28.6 x 22.7 11
PP-R PN20 Electrofusion CouplingRealcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP12357 D202.0020 20.0
PP12358 D202.0025 25.0
PP12359 D202.0032 32.0
PP12360 D202.0040 40.0
PP12361 D202.0050 50.0
PP12362 D202.0063 63.0
PP12363 D202.0075 75.0
PP12364 D202.0090 90.0
PP12365 D202.0110 110.0
PP12366 D202.0125 125.0
PP-RCT PN16 Electrofusion CouplingRealcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP12417 D203.0160 160.0
PP12418 D203.0180 180.0
PP12419 D203.0200 200.0
PP12420 D203.0225 225.0
PP12421 D203.0250 250.0
PP12422 D203.0315 315.0
PP-R End CapRealcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP12526 D290.0016 16.0
PP12527 D290.0020 20.0
PP12528 D290.0025 25.0
PP12529 D290.0032 32.0
PP12530 D290.0040 40.0
PP12531 D290.0050 50.0
PP12532 D290.0063 63.0
PP12533 D290.0075 75.0
PP12534 D290.0090 90.0
PP12535 D290.0110 110.0
PP12536 D290.0125 125.0
PP-R Crossover ConnectionRealcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP12473 D268.0020 20.0
PP12474 D268.0025 25.0
PP12475 D268.0032 32.0
217Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
PP-R
Pip
e Sy
stem
sPP-R PIPE SYSTEMS
PP-R FITTINGS
PP-R Socket Fusion Flange AdapterRealcold Stock No.
Model Price$ Excl. GST
PP12643 D295.0040
PP12644 D295.0050
PP12645 D295.0063
PP12646 D295.0075
PP12647 D295.0090
PP12648 D295.0110
PP12649 D295.0125
PP-R Spigot End CapRealcold Stock No.
Model Suit Pipe (mm) Wall Thickness (mm)
SDR Price$ Excl. GST
PP12587 D291.0160 160.0 14.6 11
PP12588 D291.0180 180.0 16.4 11
PP12589 D291.0200 200.0 18.2 11
PP12590 D291.0225 225.0 20.5 11
PP12591 D291.0250 250.0 22.7 11
PP12592 D291.0315 315.0 28.6 11
PP-R Spigot Flange AdapterRealcold Stock No.
Model Suit Pipe (mm) Wall Thickness (mm)
SDR Price$ Excl. GST
PP12700 D296.0125 125.0 11.4 11
PP12701 D296.0160 160.0 14.6 11
PP12702 D296.0200 200.0 18.2 11
PP12703 D296.0225 225.0 20.5 11
PP12704 D296.0250 250.0 22.7 11
PP12705 D296.0315 315.0 28.6 11
218Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
PP-R
Pip
e Sy
stem
s
PP-R PIPE SYSTEMSPP-R ADAPTER PIPE FITTINGS
PP-R Brass Transition Female Thread BSP Elbow 90°Realcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP12808 D220.1615 16 x 1/2”
PP12809 D220.2015 20 x 1/2”
PP12810 D220.2020 20 x 3/4”
PP12811 D220.2515 25 x 1/2”
PP12812 D220.2520 25 x 3/4”
PP12813 D220.3220 32 x 3/4”
PP12814 D220.3225 32 x 1”
PP-R Brass Transition Female Thread BSP Adapter Elbow 19 mm FI Hollow Wall 90°Realcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP13025 D223.1615 16 x 1/2”
PP13026 D223.2015 20 x 1/2”PP-R Brass Transition Female Thread BSP Spigot Elbow 90°Realcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP12865 D221.2015 20 x 1/2”
PP-R Brass Transition Male Thread BSP Elbow 90°Realcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP12916 D224.1615 16 x 1/2”
PP12917 D224.2015 20 x 1/2”
PP12918 D224.2020 20 x 3/4”
PP12919 D224.2515 25 x 1/2”
PP12920 D224.2520 25 x 3/4”
PP12921 D224.3220 32 x 3/4”
PP12922 D224.3225 32 x 1”
PP-R Brass Transition Female Thread BSP TeeRealcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP13077 D246.1615 16 x 1/2”
PP13078 D246.2015 20 x 1/2”
PP13079 D246.2020 20 x 3/4”
PP13080 D246.2515 25 x 1/2”
PP13081 D246.2520 25 x 3/4”
PP13082 D246.3220 32 x 3/4”
PP13083 D246.3225 32 x 1”
PP-R Brass Transition Female Thread BSP Adapter Elbow 30 mm FI Hollow Wall 90°Realcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP12973 D222.1615 16 x 1/2”
PP12974 D222.2015 20 x 1/2”
PP-R Brass Transition Male Thread BSP TeeRealcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP13134 D247.1615 16 x 1/2”
PP13135 D247.2015 20 x 1/2”
PP13136 D247.2020 20 x 3/4”
PP13137 D247.2515 25 x 1/2”
PP13138 D247.2520 25 x 3/4”
PP13139 D247.3220 32 x 3/4”
PP13140 D247.3225 32 x 1”
219Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
PP-R
Pip
e Sy
stem
sPP-R PIPE SYSTEMS
PP-R ADAPTER PIPE FITTINGS
PP-R Brass Transition Female Thread BSP Adapter Hollow Wall 19 mmRealcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP13309 D277.1615 16 x 1/2”
PP13310 D277.2015 20 x 1/2”
PP-R Brass Transition Male Thread BSP AdapterRealcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP13191 D270.1615 16 x 1/2”
PP13192 D270.2015 20 x 1/2”
PP13193 D270.2020 20 x 3/4”
PP13194 D270.2515 25 x 1/2”
PP13195 D270.2520 25 x 3/4”
PP13196 D270.3220 32 x 3/4”
PP13197 D270.3225 32 x 1”
PP13198 D270.4025 40 x 1”
PP13199 D270.4032 40 x 11/4”
PP13200 D270.5032 50 x 11/4”
PP13201 D270.5040 50 x 11/2”
PP13202 D270.6350 63 x 2”
PP13203 D270.7565 75 x 21/2”
PP13204 D270.9080 90 x 3”
PP13205 D270.1110 110 x 4”
PP13206 D270.1212 125 x 5"
PP-R Brass Transition Female Thread BSP Adapter Hollow Wall 30 mmRealcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP13257 D276.1615 16 x 1/2”
PP13258 D276.2015 20 x 1/2”
PP-R Brass Transition Female Thread BSP AdapterRealcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP13361 D273.1615 16 x 1/2”
PP13362 D273.2015 20 x 1/2”
PP13363 D273.2020 20 x 3/4”
PP13364 D273.2515 25 x 1/2”
PP13365 D273.2520 25 x 3/4”
PP13366 D273.3220 32 x 3/4”
PP13367 D273.3225 32 x 1”
PP13368 D273.4025 40 x 1”
PP13369 D273.4032 40 x 11/4”
PP13370 D273.5032 50 x 11/4”
PP13371 D273.5040 50 x 11/2”
PP13372 D273.6350 63 x 2”
PP13373 D273.7565 75 x 21/2”
PP13374 D273.9080 90 x 3”
PP13375 D273.1110 110 x 4”
PP13376 D273.1212 125 x 5”
PP-R Union Complete Brass JointRealcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP13427 D280.0016 16.0
PP13428 D280.0020 20.0
PP13429 D280.0025 25.0
PP13430 D280.0032 32.0
PP13431 D280.0040 40.0
PP13432 D280.0050 50.0
PP13433 D280.0063 63.0
PP13434 D280.0075 75.0
PP13435 D280.0090 90.0
220Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
PP-R
Pip
e Sy
stem
s
PP-R PIPE SYSTEMSPP-R ADAPTER PIPE FITTINGS
PP-R Union to Female Thread BSP AdapterRealcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP13610 D283.1615 16 x 1/2”
PP13611 D283.2015 20 x 1/2”
PP13612 D283.2020 20 x 3/4”
PP13613 D283.2515 25 x 1/2”
PP13614 D283.2520 25 x 3/4”
PP13615 D283.3220 32 x 3/4”
PP13616 D283.3225 32 x 1”
PP13617 D283.4032 40 x 11/4”
PP13618 D283.5040 50 x 11/2”
PP13619 D283.6350 63 x 2”
PP13620 D283.7565 75 x 21/2”
PP-R Union Male ISO Adapter for D281Realcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP13549 D282.1620 16 x 3/4”
PP13550 D282.2020 20 x 3/4”
PP13551 D282.2025 20 x 1”
PP13552 D282.2520 25 x 3/4”
PP13553 D282.2525 25 x 1”
PP13554 D282.3232 32 x 11/4”
PP13555 D282.4040 40 x 11/2”
PP13556 D282.5045 50 x 13/4”
PP13557 D282.6360 63 x 23/8”
PP13558 D282.7570 75 x 23/4”
PP13559 D282.9085 90 x 31/2”
PP-R Union Female ISO Adapter for D282Realcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP13486 D281.1620 16 x 3/4”
PP13487 D281.2020 20 x 3/4”
PP13488 D281.2025 20 x 1”
PP13489 D281.2520 25 x 3/4”
PP13490 D281.2525 25 x 1”
PP13491 D281.3225 32 x 1”
PP13492 D281.3232 32 x 11/4”
PP13493 D281.4032 40 x 11/4”
PP13494 D281.4040 40 x 11/2”
PP13495 D281.5045 50 x 13/4”
PP13496 D281.6360 63 x 23/8”
PP13497 D281.7570 75 x 23/4”
PP13498 D281.9085 90 x 31/2”PP-R Union to Male Thread BSP AdapterRealcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP13671 D284.1615 16 x 1/2”
PP13672 D284.2015 20 x 1/2”
PP13673 D284.2020 20 x 3/4”
PP13674 D284.2515 25 x 1/2”
PP13675 D284.2520 25 x 3/4”
PP13676 D284.3220 32 x 3/4”
PP13677 D284.3225 32 x 1”
PP13678 D284.4032 40 x 11/4"
PP13679 D284.5040 50 x 11/2"
PP13680 D284.6350 63 x 2”
PP13681 D284.7565 75 x 21/2”
PP Union 10 Bar*Realcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP13732 D287.0020 20.0
PP13733 D287.0025 25.0
PP13734 D287.0032 32.0
PP13735 D287.0040 40.0
PP13736 D287.0050 50.0
PP13737 D287.0063 63.0
* Cold water application only
221Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
PP-R
Pip
e Sy
stem
sPP-R PIPE SYSTEMS
PP-R ADAPTER PIPE FITTINGS
PP-R Saddle (Pipe x Branch)Realcold Stock No.
Model Suit Pipe (mm) Price$ Excl. GST
PP13788 D250.4020 40 x 20
PP13789 D250.4025 40 x 25
PP13790 D250.4032 40 x 32
PP13791 D250.5020 50 x 20
PP13792 D250.5025 50 x 25
PP13793 D250.5032 50 x 32
PP13794 D250.6320 63 x 20
PP13795 D250.6325 63 x 25
PP13796 D250.6332 63 x 32
PP13797 D250.7520 75 x 20
PP13798 D250.7525 75 x 25
PP13799 D250.7532 75 x 32
PP13800 D250.9020 90 x 20
PP13801 D250.9025 90 x 25
PP13802 D250.9032 90 x 32
PP13803 D250.40-6320 40-63 x 20
PP13804 D250.40-6325 40-63 x 25
PP13805 D250.40-6332 40-63 x 32
PP13812 D250.75-12520 75-125 x 20
PP13813 D250.75-12525 75-125 x 25
PP13814 D250.75-12532 75-125 x 32
PP13815 D250.75-12540 75-125 x 40
PP13816 D250.110-12550 110-125 x 50
PP13817 D250.110-12563 110-125 x 63
PP13818 D250.160-25020 160-250 x 20
PP13819 D250.160-25025 160-250 x 25
PP13820 D250.160-25032 160-250 x 32
PP13821 D250.160-25040 160-250 x 40
PP13822 D250.160-25050 160-250 x 50
PP13823 D250.160-25063 160-250 x 63
PP13824 D250.315-63020 315-630 x 20
PP13825 D250.315-63025 315-630 x 25
PP13826 D250.315-63032 315-630 x 32
PP13827 D250.315-63040 315-630 x 40
PP13828 D250.315-63050 315-630 x 50
PP13829 D250.315-63063 315-630 x 63
222Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
PP-R
Pip
e Sy
stem
s
PP-R PIPE SYSTEMSPP-R ADAPTER PIPE FITTINGS
PP-R Saddle Thread BSPRealcold Stock No.
Model Suit Pipe (mm) Price$ Excl. GST
Male Thread BSP
PP13915 D254.40-6315 40-63 x 1/2”
PP13916 D254.6320 63 x 3/4”
PP13917 D254.75-12515 75-125 x 1/2"
PP13918 D254.75-12520 75-125 x 3/4"
PP13919 D254.75-12525 75-125 x 1"
PP13920 D254.75-12532 75-125 x 1 1/4"
PP13921 D254.90-12532 90-125 x 1 1/4"
PP13922 D254.110-12540 110-125 x 1 1/2"
PP13923 D254.12550 125 x 2"
PP13924 D254.160-25015 160-250 x 1/2"
PP13925 D254.160-25020 160-250 x 3/4"
PP13926 D254.16025 160-250 x 1"
PP13927 D254.160-25032 160-250 x 1 1/4"
PP13928 D254.160-25040 160-250 x 1 1/2"
PP13929 D254.160-25050 160-250 x 2"
PP13930 D254.315-63015 315-630 x 1/2"
PP13931 D254.315-63020 315-630 x 3/4"
PP13932 D254.315-63025 315-630 x 1"
PP13933 D254.315-63032 315-630 x 1 1/4"
PP13934 D254.315-63040 315-630 x 1 1/2"
PP13935 D254.315-63050 315-630 x 2"
Female Thread BSP
PP13972 D257.40-6315 40-63 x 1/2”
PP13973 D257.6320 63 x 3/4”
PP13974 D257.75-12515 75-125 x 1/2"
PP13975 D257.75-12520 75-125 x 3/4"
PP13976 D257.75-12525 75-125 x 1"
PP13977 D257.75-12532 75-125 x 1 1/4"
PP13978 D257.90-12532 90-125 x 1 1/4"
PP13979 D257.110-12540 110-125 x 1 1/2"
PP13980 D257.12550 125 x 2"
PP13981 D257.160-25015 160-250 x 1/2"
PP13982 D257.160-25020 160-250 x 3/4"
PP13983 D257.16025 160-250 x 1"
PP13984 D257.160-25032 160-250 x 1 1/4"
PP13985 D257.160-25040 160-250 x 1 1/2"
PP13986 D257.160-25050 160-250 x 2"
PP13987 D257.315-63015 315-630 x 1/2"
PP13988 D257.315-63020 315-630 x 3/4"
PP13989 D257.315-63025 315-630 x 1"
PP13990 D257.315-63032 315-630 x 1 1/4"
PP13991 D257.315-63040 315-630 x 1 1/2"
PP13992 D257.315-63050 315-630 x 2"
223Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
PP-R
Pip
e Sy
stem
sPP-R PIPE SYSTEMS
PP-R ADAPTER PIPE FITTINGS
Union Flat Gasket (multi-size)Realcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP14353 BR8490f.16/20/25 16/20/25
PP14354 BR8490f.20/25/32 20/25/32
PP-R Female Thread BSP Elbow Hollow WallRealcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP14091 D226.1615 16 x 1/2”
PP14092 D226.2015 20 x 1/2”
PP14093 D226.2515 25 x 1/2”
Union Flat GasketRealcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP14405 BR8490f.32 32.0
PP14406 BR8490f.40 40.0
PP14407 BR8490f.50 50.0
PP14408 BR8490f.63 63.0
PP14409 BR8490f.75 75.0
PP14410 BR8490f.90 90.0
PP-R SubassemblyRealcold Stock No.
Model Suit Pipe (mm)
Outlets Price$ Excl. GST
PP14195 D266.2015 20 x 1/2” 2
PP14196 D267.2015 20 x 1/2” 6
PP-R Backplate Tee Female Thread BSPRealcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP14144 D248.2015 20 x 1/2”
PP-R Backplate Elbow Female Thread BSPRealcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP14036 D225.1615 16 x 1/2”
PP14037 D225.2015 20 x 1/2”
PP14038 D225.2515 25 x 1/2”
PP14039 D225.2520 25 x 3/4”
PP14040 D225.3220 32 x 3/4”
PP-R Union Male Thread BSP ISO Stainless SteelRealcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP14247 D285.2015 20 x 1/2”
PP14248 D285.2520 25 x 3/4”
PP14249 D285.3225 32 x 1”
PP-R Union Female Thread BSP ISO Stainless SteelRealcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP14300 D286.2015 20 x 1/2”
PP14301 D286.2520 25 x 3/4”
PP14302 D286.3225 32 x 1”
224Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
PP-R
Pip
e Sy
stem
s
PP-R PIPE SYSTEMSPP-R VALVES
PP-R Angle Seat Valve w/o Draining ConnectionRealcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP14633 BR8700.20 20.0
PP14634 BR8700.25 25.0
PP14635 BR8700.32 32.0
PP14636 BR8700.40 40.0
PP-R Ball Valve Socket FusionRealcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP14795 D301.0020 20.0
PP14796 D301.0025 25.0
PP14797 D301.0032 32.0
PP14798 D301.0040 40.0
PP14799 D301.0050 50.0
PP14800 D301.0063 63.0
PP14801 D301.0075 75.0
PP-R Ball Valve PP Union 10 BarRealcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP14852 D302.0020 20.0
PP14853 D302.0025 25.0
PP14854 D302.0032 32.0
PP14855 D302.0040 40.0
PP14856 D302.0050 50.0
PP14857 D302.0063 63.0
PP14858 D302.0075 75.0
PP-R Drain Valve for Socket Welding, F&MRealcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP14741 D390.0020 20.0
PP14742 D390.0025 25.0
PP14743 D390.0032 32.0
PP14744 D390.0040 40.0
225Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
PP-R
Pip
e Sy
stem
sPP-R PIPE SYSTEMS
PP-R ACCESSORIES
Backing Flanges for Flange Adapter, Table E Galvanized*Realcold Stock No.
Model To Suit Pipe (mm x inch)
Dia. of Flange (mm) No of Holes
Hole Dia (mm)
PCD (mm)
Flange Thickness (mm)
Price$ Excl. GST
Outside Inside
PP15276 5451.0040 40 x 1 1/4" 120.0 52.0 4 14.0 87.0 8.0
PP15277 5451.0050 50 x 1 1/2" 135.0 62.0 4 14.0 98.0 9.0
PP15278 5451.0063 63 x 2" 150.0 78.0 4 18.0 114.0 10.0
PP15279 5451.0075 75 x 2 1/2" 165.0 92.0 4 18.0 127.0 10.0
PP15280 5451.0090 90 x 3" 185.0 110.0 4 18.0 146.0 12.0
PP15281 5451.0110 110 x 4" 215.0 140.0 8 18.0 178.0 13.0
PP15282 5451.4125 125 x 4" 215.0 148.0 8 18.0 178.0 14.0
PP15283 5451.5125 125 x 5" 255.0 148.0 8 18.0 210.0 14.0
PP15284 5451.0160 160 x 6" 280.0 176.0 8 22.0 235.0 17.0
PP15285 5451.0180 180 x 6" 280.0 178.0 8 22.0 235.0 17.0
PP15286 5451.0200 200 x 8" 335.0 234.0 8 22.0 292.0 19.0
PP15287 5451.0225 225 x 8" 335.0 236.0 8 22.0 292.0 19.0
PP15288 5451.0250 250 x 10" 405.0 288.0 12 22.0 356.0 22.0
PP15289 5451.0315 315 x 12" 405.0 382.0 12 26.0 406.0 25.0
* Nylon Coated T/E Backing Flanges available. Please ask for pricing.
Backing Flanges for Flange Adapter Nylon Coated, PN16Realcold Stock No.
Model To Suit Pipe (mm x inch)
Dia. of Flange (mm) No of Holes
Hole Dia (mm)
PCD (mm)
Flange Thickness (mm)
Price$ Excl. GST
Outside Inside
PP15339* 5415.0040 40 x 1 1/4" 140.0 51.0 4 18.0 100.0 18.0
PP15340 5415.0050 50 x 1 1/2" 150.0 62.0 4 18.0 110.0 18.0
PP15341 5415.0063 63 x 2" 165.0 78.0 4 18.0 125.0 18.0
PP15342 5415.0075 75 x 2 1/2" 185.0 92.0 4 18.0 145.0 18.0
PP15343 5415.0090 90 x 3" 200.0 110.0 8 18.0 160.0 18.0
PP15344 5415.0110 110 x 4" 220.0 133.0 8 18.0 180.0 18.0
PP15345 5415.4125 125 x 4" 220.0 149.0 8 18.0 180.0 18.0
PP15346* 5415.5125 125 x 5" 255.0 149.0 8 18.0 210.0 14.0
PP15347 5415.0160 160 x 6" 285.0 178.0 8 22.0 240.0 24.0
* Galvanised, Nylon coated
Wall Inlet Plug with GasketRealcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP15460 BR9900.1/2 1/2"
PP15461 BR9900.3/4 3/4"
Gasket for Wall Inlet PlugRealcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP15512 BR9910.1/2 1/2"
PP15513 BR9910.3/4 3/4"
Note: Dress (Bolt) sets available in both Galvanised and Stainless Steel for all connection options. Please discuss with your Realcold representative.
226Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
PP-R
Pip
e Sy
stem
s
PP-R PIPE SYSTEMSPP-R ACCESSORIES
Flat Gasket Table ERealcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP15397 9644.0040 40.0
PP15398 9644.0050 50.0
PP15399 9644.0063 63.0
PP15400 9644.0075 75.0
PP15401 9644.0090 90.0
PP15402 9644.4125 110.0
PP15403 9644.5125 125-4"
PP15404 9644.0125 125-5"
PP15405 9644.0160 160.0
PP15406 9644.0180 180.0
PP15407 9644.0200 200.0
PP15408 9644.0225 225.0
PP15409 9644.0250 250.0
PP15410 9644.0315 315.0
Insulated Pipe Clamp (with spacers)Realcold Stock No.
Model Dia (mm) Price$ Excl. GST
PP15564 D430.016-M8 16-M8
PP15565 D430.020-M8 20,M8
PP15566 D430.025-M10 25,M10
PP15567 D430.032-M10 32,M10
PP15568 D430.040-M10 40,M10
PP15569 D430.050-M10 50,M10
PP15570 D430.063 63,M10
PP15571 D430.075 75,M10
PP15572 D430.090 90,M10
PP15573 D430.110 110,M10
PP15574 D430.125 125,M10
PP15575 D430.160 160,M10
Galvanized Yoke Clamp
PP15600 FM18-180 180,M12
PP15601 FM18-203 200,M12
PP15602 FM18-228 225,M12
PP15603 FM18-252 250,M12
PP15604 FM18-318 250,M12
Flat Gasket PN16Realcold Stock No.
Model Suit Pipe (mm)
Price$ Excl. GST
PP15426 9644.0040PN16 40.0
PP15427 9644.0050PN16 50.0
PP15428 9644.0063PN16 63.0
PP15429 9644.0075PN16 75.0
PP15430 9644.0090PN16 90.0
PP15431 9644.4125PN16 110.0
PP15432 9644.5125PN16 125-4"
PP15433 9644.0125PN146 125-5"
PP15434 9644.0160PN16 160.0
PP15435 9644.0180PN16 180.0
PP15436 9644.0200PN16 200.0
PP15437 9644.0225PN16 225.0
PP15438 9644.0250PN16 250.0
PP15439 9644.0315PN16 315.0
BR Pipe BracketRealcoldStock No.
Model Dia (mm) Price$ Excl. GST
PP16150 BR65.00.114.16 16
PP16151 BR65.00.114.20 20
PP16152 BR65.00.114.25 25
PP16153 BR65.00.114.32 32
PP16154 BR65.00.115.40 40
PP16155 BR65.00.115.50 50
PP16156 BR65.00.115.63 63
PP16157 BR65.00.115.75 75
PP16158 BR65.00.115.90 90
PP16159 BR65.00.115.110 110
PP16160 BR65.00.115.140 140
PP16161 BR65.00.115.160 160
Note: Dress (Bolt) sets available in both Galvanised and Stainless Steel for all connection options.
Please discuss with your Realcold representative.
227Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
PP-R
Pip
e Sy
stem
sPP-R PIPE SYSTEMS
PP-R INSTALLATION TOOLS
Welding Mandrels for the Welding of SaddlesRealcold Stock No.
Model Suit Pipe (mm) Price$ Excl. GST
PP16103 8985e.40-63x20 40-63 for 20 mm off take
PP16104 8985e.40-63x25 40-63 for 25 mm off take
PP16105 8985e.40-63x32 40-63 for 32 mm off take
PP16106 8985e.75-125x20 75-125 for 20 mm off take
PP16107 8985e.75-125x25 75-125 for 25 mm off take
PP16108 8985e.75-125x32 75-125 for 32 mm off take
PP16109 8985e.75-125x40 75-125 for 40 mm off take
PP16110 8985e.75-125x50 75-125 for 50 mm off take
PP16111 8985e.75-125x63 75-125 for 63 mm off take
PP16112 8985e.160-250x20 160-250 for 20 mm off take
PP16113 8985e.160-250x25 160-250 for 25 mm off take
PP16114 8985e.160-250x32 160-250 for 32 mm off take
PP16115 8985e.160-250x40 160-250 for 40 mm off take
PP16116 8985e.160-250x50 160-250 for 50 mm off take
PP16117 8985e.160-250x63 160-250 for 63 mm off take
PP16118 8985e.315-630x20 315-630 for 20 mm off take
PP16119 8985e.315-630x25 315-630 for 25 mm off take
PP16120 8985e.315-630x32 315-630 for 32 mm off take
PP16121 8985e.315-630x40 315-630 for 40 mm off take
PP16122 8985e.315-630x50 315-630 for 50 mm off take
PP16123 8985e.315-630x63 315-630 for 63 mm off take
Drill for Installation of Welding SaddlesRealcold Stock No.
Model Description Price$ Excl. GST
PP15984 BR8986b.25 20-25 mm
PP15985 BR8986b.32 32 mm
PP15986 BR8986b.40 40 mm
PP15987 BR8986b.50 50 mm
PP15988 BR8986b.63 63 mm
228Listed prices & specifications are subject to alteration without notice. For more information visit our website at www.realcold.co.nz.
PP-R
Pip
e Sy
stem
s
Miscellaneous Installation ToolsRealcold Stock No.
Model Description Price$ Excl. GST
PP15920 PC40 Pipe Cutter 16-40 mm
PP15921 BR8975.50-110 Pipe Cutter 50-110 mm
PP15922 BR8974. Hand Scraper
PP15923 1045-TFA Hand Socket Fusion Welding Tool 16-63 mm
PP15924 BR8981.20-32 Hand Socket Fusion Welding Tool 20-32 mm
PP15925 10125/TF Hand Socket Fusion Welding Tool up to 125 mm
PP15926 7125 Bench Socket Welding Machine w/Mandrels 50-125 mm
PP15927 BR8990. Electrofusion Machine for Electrofusion Socket Welding
PP15928 BR8983.7 Repairing Set Size 7
PP15929 BR8983.11 Repairing Set Size 11
PP15930 BR8593. Repairing Plug (up to 10 mm)
PP15931 BR8986a. Chamfering Device
Welding Mandrels for Socket Fusion WelderRealcold Stock No.
Model Suit Pipe (mm) Price$ Excl. GST
PP16042 M16-A 16.0
PP16043 M20-A 20.0
PP16044 M25-A 25.0
PP16045 M32-A 32.0
PP16046 M40-A 40.0
PP16047 M50-A 50.0
PP16048 M63-A 63.0
PP16049 M75-A 75.0
PP16050 M90-A 90.0
PP16051 M110-A 110.0
PP16052 M125-A 125.0
PP-R PIPE SYSTEMSPP-R INSTALLATION TOOLS
PP15925
PP15923
PP15922PP15920
Peeling Tool for Tube “Stabi”Realcold Stock No.
Model Description Price$ Excl. GST
PP15932 BR8977.16+20 16 + 20 mm
PP15933 BR8977.20+25 20 + 25 mm
PP15934 BR8977.32+40 32 + 40 mm
PP15935 BR8977.50+63 50 + 63 mm
PP15936 BR8977.75 75 mm
PP15937 BR8977.90 90 mm
PP15938 BR8977.110 110 mm
PP15939 BR8977.125 125 mm
CompressorsRealcold Ltd standard warranty covers start up of all compressors.
Compressors will be repaired or replaced under warranty if re-turned within 12 months of purchase date, provided that com-pressor, complete with original electrics, is returned to point of purchase, freight paid, accompanied by a compressor failure report.
Realcold Ltd shall not be held responsible for failure or damage resulting from misuse or incorrect installation.
Condensing UnitsSealed & Semi-Sealed
Warranty is included in the price listed for condensing units and includes replacement of all components for a 12 month period from date of purchase, provided component is returned along with Goods Returned Form to point of purchase, freight paid.
Note:
Replacement components will be debited against the account of the purchaser, with credit to follow upon receipt and inspection of faulty component.
Realcold Ltd shall in no event be liable for any indirect or conse-quential loss or damage whatsoever.
Refer to www.realcold.co.nz/legal/terms-conditions.aspx for our General Terms of Trade. Goods Returned Forms are available from your representative, or any of our branches.
COMPRESSOR AND CONDENSING UNIT WARRANTY
The warranty is applicable to Gree products purchased from Realcold Limited and installed in New Zealand. Mitsubishi Heavy Industries warranty is held by Mitsubishi Heavy Indus-tries Air-Conditioners Australia Pty Ltd.
Realcold Limited (herein called the company) warrants the prod-ucts are free of defects from manufacture. Any proven defect will be rectified by the company, or an authorized service agent, free of charge within the appropriate time limits and subject to the conditions set out on the New Zealand warranty card supplied with the air conditioner.
5 YEAR WARRANTY Residential Installation
2 YEAR WARRANTY Commercial Installation (See notes below)
Multi Inverter Air Conditioners (only 24 month warranty applies for process cooling and commercial applications).
Split Type Hi-wall Air Conditioners (only 24 month warranty ap-plies for process cooling and commercial applications).
Window Air Conditioners (only 24 month warranty applies for pro-cess cooling and commercial applications).
Heat Recovery Ventilators (only 24 month warranty applies for process cooling and commercial applications).
Notes
1 In home service available in major metropolitan areas or within 30 km from service agents only. Consumers in ar-eas other than the above will require prior authorization from the company for any mileage and travel charges.
2 Multi, Split and / or Ducted Air Conditioners must be in-stalled by a qualified installer.
3 Regular maintenance must be carried out at intervals not exceeding one year and the maintenance record com-pleted on the retained warranty card as each service occurs.
4 The removable portion of the warranty card must be fully completed and returned to the company to register your warranty.
Contractor / Installer responsibilities:
• Install the air conditioner as per the manufacturer’s instructions.
• Installation is to be done by a qualified tradesperson following best trade practices.
• The equipment must be safely accessible using a three metre ladder. If the unit is not accessible safely you may be required to arrange safe working conditions. This is not a cost to warranty.
• Explain the operation to the owner / occupier.
• Ensure the removable portion of the warranty card has been completed and returned to Realcold Limited.
• Ensure that the owner / occupier retain the remainder of the warranty card.
• Explain to the owner / occupier that the warranty will be void unless the unit is serviced annually.
Before making a warranty claim please consider the following:
• Check and reset the power supply.
• Check the air conditioner’s remote control settings (pay at-tention to timers and mode operation).
• Ensure filters and drains are clear.
• Check either unit for obstructions reducing air flow.
• Are the doors or windows open, or are there extra sources of heat in the room?
• Check the refrigerant charge.
To make a warranty claim:
• Ensure all details on the warranty card have been com-pleted and your warranty has been registered.
• As the installer you will be expected to act as the service agent.
• Call your local Realcold branch and quote the model, se-rial number and the warranty card number to obtain a warranty registration card. You may be asked to provide proof of purchase to establish warranty. (This authoriza-tion number is for administration purposes only and the company accepts no liability with the issue of this number. Failure to obtain this number may delay settlement of your warranty).
• Return all damaged or defective parts or materials to your local Realcold branch. Please fill in a goods return form, quoting you warranty authorization number. These parts are required for testing purposes.
Notes
Unless components are found to be defective and then ex-changed or repaired it is deemed by Realcold Limited that this was not covered under warranty and there will be a charge for non-warranty calls.
GREE AIR CONDITIONINGWARRANTY INFORMATION
MHI AIR CONDITIONING WARRANTY INFORMATION
The Warranty on all Mitsubishi Heavy Industry product is cov-ered by Mitsubishi Heavy Industries Air-Conditioners Australia Pty Ltd (MHI) and its New Zealand subsidiary. This warranty covers all MHI product purchased from Realcold Ltd and in-stalled in New Zealand.
Please see MHI for their full warranty terms and conditions.
5 YEAR WARRANTY All Products Excluding the KX Range (service - see notes below)
5 YEAR WARRANTY KX Range Residential Installations (service - see notes below)
3 YEAR WARRANTY KX Range Commercial Installations (service - see notes below)
Contractor/Installer responsibilities:
• Install the air conditioner as per the manufacturer’s instructions
• Installation is to be done by a qualified tradesperson following best trade practices
• The equipment must be safely accessible using a three metre ladder. If the unit is not accessible safely you may be required to arrange safe working conditions. This is not a cost to warranty
• Explain the operation to the owner / occupier
• Explain to the owner / occupier that the warranty will be void unless the unit is serviced annually
Before making a warranty claim please consider the following:
• Check and reset the power supply
• Check the air conditioner’s remote control settings (pay at-tention to timers and mode operation)
• Ensure Drains and Filters are clear
• Check either unit for obstructions reducing air flow
• Are the doors or windows open, or are there extra sourc-es of heat in the room?
• Check the Refrigerant Charge
Warranty Service Request
• To make a Warranty Service request please visit www.mhiaa.com.au
• Please fill in the electronic Warranty Request Form and hit send.
• The Warranty Service Request form is found under War-ranty, Warranty Service Request on the above website.
• A copy of MHI’s warranty card is also available.
• MHI will contact the owner and arrange to send a war-ranty service agent to check the air conditioner / heat pump.
Note
Unless components are found to be defective and then ex-changed or repaired it is deemed by MHI that this was not cov-ered under warranty and there will be a charge for non-warranty calls
Air Conditioning Warranty
Coolbreeze12 Months Parts Only on Evaporative Coolers
Gree5 Years Parts & Labour on all Models (Residential Installations Only)2 Years Parts & Labour on all Models (Commercial Installations Only)Refer to Gree Air Conditioning Warranty Information for exceptions to the above.
Mitsubishi (Warranty provided by MHI)5 Years Parts & Labour on all Models (Except KX)5 Years Parts & Labour on KX Range (Residential Installations Only)3 Years Parts & Labour on KX Range (Commercial Installations Only)See MHI Air Conditioning Warranty Information for full details.
AIR CONDITIONINGWARRANTY INFORMATION
PRESSURE TEMPERATURE CHART
Temp °C
Pressure kPaTemp
°CR134A R22 R407C R410A R404A R507A MO59
R417AMO79 R422A
MO99 R438A
CO2 (R744)
Butane (R600)
Ammonia R717
R32 R290
-40 102 4 32 74 30 37 52 21 36 905 7 72 83 7 -40
-38 90 15 11 92 43 52 34 35 16 981 21 80 90 21 -38
-36 75 28 6 112 59 68 14 50 3 1061 28 89 110 — -36
-34 68 34 11 122 66 76 3 57 8 1145 41 98 131 41 -34
-32 52 48 24 144 83 93 9 74 21 1234 55 108 152 55 -32
-30 34 63 37 168 101 112 21 91 34 1328 69 120 172 69 -30
-28 16 79 52 194 120 132 34 110 48 1426 83 132 193 83 -28
-26 3 96 68 221 141 153 48 130 63 1592 97 145 221 97 -26
-24 8 105 77 235 152 164 56 141 72 1638 110 159 248 110 -24
-22 19 123 94 265 174 188 72 163 89 1751 124 174 276 124 -22
-20 32 144 113 298 199 213 88 188 108 1870 145 190 303 145 -20
-18 45 165 134 332 225 240 107 213 128 1994 159 208 338 159 -18
-16 59 189 156 369 252 268 126 241 149 2124 179 226 365 179 -16
-14 66 201 168 388 267 283 137 255 160 2259 200 246 407 200 -14
-12 82 226 192 429 297 315 158 285 183 2401 221 268 441 221 -12
-10 99 254 219 472 330 348 181 317 209 2549 241 291 483 241 -10
-8 117 282 246 516 363 383 206 351 236 2703 269 315 524 269 -8
-6 137 312 276 565 400 421 232 387 264 2863 290 341 565 290 -6
-4 147 328 292 590 419 440 246 405 279 3030 317 369 614 317 -4
-2 169 361 325 642 458 480 275 445 311 3204 345 398 662 345 -2
0 192 396 359 697 499 523 305 486 344 3285 372 429 710 372 0
2 216 434 396 755 543 567 338 530 380 3769 407 463 765 400 2
4 241 473 436 816 589 615 372 576 417 4183 434 498 821 434 4
6 255 493 456 848 612 639 390 600 436 4630 469 535 876 469 6
8 283 535 499 914 662 690 427 650 478 5111 483 574 938 500 8
10 313 580 543 983 714 744 467 702 521 5629 552 615 1007 540 10
12 345 626 728 1060 781 801 582 796 678 5903 586 659 1069 586 12
14 379 676 784 1137 839 860 628 855 730 6188 621 705 1138 620 14
16 396 701 813 1177 869 891 652 885 757 6484 655 753 1214 655 16
18 432 754 874 1260 931 954 703 948 814 6792 690 804 1289 689 18
20 470 809 936 1347 996 1020 755 1014 873 7114 724 857 1372 724 20
22 511 867 1003 1437 1064 1090 810 1084 934 — 793 914 1455 793 22
24 553 927 1071 1532 1135 1162 867 1156 999 — 827 973 1538 827 24
26 575 958 1107 1581 1171 1200 897 1193 1033 — 896 1034 1627 862 26
28 621 1023 1180 1682 1248 1278 959 1270 1102 — 931 1099 1724 931 28
30 669 1091 1258 1788 1327 1359 1023 1351 1174 — 965 1167 1820 965 30
32 719 1161 1338 1899 1410 1443 1091 1435 1249 — 1034 1238 1924 1034 32
34 772 1235 1422 2014 1496 1531 1161 1522 1328 — 1069 1312 2034 1103 34
36 799 1273 1465 2073 1540 1577 1197 1567 1369 — 1138 1390 2144 1138 36
38 856 1351 1555 2196 1633 1671 1272 1661 1452 — 1207 1471 2255 1207 38
40 915 1432 1648 2324 1728 1769 1350 1758 1539 — 1276 1555 2379 1276 40
42 977 1517 1744 2458 1828 1870 1431 1859 1630 — 1345 1643 2496 1344 42
44 1042 1605 1845 2597 1931 1976 1516 1964 1724 — 1413 1735 2627 1413 44
46 1076 1651 1897 2668 1985 2031 1560 2017 1773 — 1482 1830 2758 1482 46
48 1145 1744 2004 2816 2095 2143 1649 2129 1873 — 1551 1930 2896 1551 48
50 1217 1842 2115 2970 2209 2260 1743 2245 1977 — 1620 2033 3041 1620 50
52 1292 1942 2230 3129 2328 2382 1840 2365 2084 — 1689 2141 3185 1689 52
54 1370 2047 2349 3295 2452 2508 1941 2490 2196 — 1758 2253 3344 1758 54
56 1411 2101 2411 3381 2516 2573 1993 2555 2254 — 1862 2369 — 1862 56
58 1494 2211 2537 3557 2647 2708 2100 2687 2373 — 1931 2489 — 1931 58
60 1580 2326 2668 3741 2784 2848 2211 2825 2495 — 2000 2614 — 1999 60
This chart is a guideline only. Please call Realcold’s Technical Team for more information.
Notes
For Terms & Conditions of Trade, please go to: www.realcold.co.nz/legal/terms-conditions.aspx
Notes
For Terms & Conditions of Trade, please go to: www.realcold.co.nz/legal/terms-conditions.aspx
Branch Locations
Auckland Branch / Support Office9 Prescott Street, Penrose 1061PO Box 12072, Penrose 1642Orders Direct Line: 0800 11 66 90Orders Direct Fax: 09 526 5748Phone: 09 526 5700Fax: 09 526 5721Email: [email protected]
Christchurch71 Harman Street, Addington, Christchurch 8024PO Box 9150, Tower Junction, Christchurch 8149Phone: 03 338 8084 Fax: 03 338 9938Email: [email protected]
Dunedin18 Roberts Street, Dunedin 9016PO Box 2536, Dunedin 9044Phone: 03 467 7106 Fax: 03 467 7107Email: [email protected]
Hamilton43 Lake Road, Frankton, Hamilton 3204PO Box 5238, Frankton, Hamilton 3242Phone: 07 848 2111 Fax: 07 848 2333Email: [email protected]
HastingsCnr St Aubyn Street East & Miller Street Hastings 4122PO Box 488, Hastings 4156Phone: 06 870 3714 Fax: 06 870 3726Email: [email protected]
North HarbourUnit C, 28 Canaveral Drive, Albany 0632PO Box 305354, Triton PlazaNorth Shore City 0757Phone: 09 477 0274 Fax: 09 478 2309Email: [email protected]
Palmerston NorthUnit 2, 597-599 Tremaine Avenue PO Box 4368, Manawatu Mail Centre Palmerston North 4442Phone: 06 357 9101 Fax: 06 357 9103Email: [email protected]
Tauranga5 Barberry Street, Judea, Tauranga 3110PO Box 15610, Tauranga 3144Phone: 07 571 0096 Fax: 07 571 0097Email: [email protected]
Wellington54 Fitzherbert Street, Petone, Lower Hutt 5012PO Box 38527, Wellington Mail Centre Lower Hutt 5045Phone: 04 569 3072 Fax: 04 568 2210Email: [email protected]
Whangarei Unit A1, 7 - 11 Nell Place, Raumanga Whangarei 0110PO Box 25056, Whangarei Mail CentreWhangarei 0148Phone: 09 430 4476 Fax: 09 430 7465Email: [email protected]
0800 11 66 90www.realcold.co.nz