Top Banner
The primary way to communicate around industrial manufacturing plants is utilizing a facility Public Address/General Alarm (PA/GA) system. This type of system serves as a vital link between the operators in the facility’s main control room and personnel who work within the plant in capacities that include system maintenance, engineering, process analysis and site security. Not only is the PA/GA system used for routine select or zone communication, it also is the primary communication medium used for critical emergency response broadcasting. G U A R D I A N T E L E C O M Product and Services Guide PA/GA — Paging Systems Components 19 SECTION www.guardiantelecom.com ISO-9001:2008 Certification Today's Quality Creates Our Future PSG-8.2.3D
16

Product and Services Guide · amp. 1 amp. 2 amp. 3 a mp. 4 sta nd by vox threshold adjustment power a mp. 1 a2 a3 a4 sta nd by f failure record c current failure f c f c f c f c f

Jul 28, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Product and Services Guide · amp. 1 amp. 2 amp. 3 a mp. 4 sta nd by vox threshold adjustment power a mp. 1 a2 a3 a4 sta nd by f failure record c current failure f c f c f c f c f

The primary way to communicate around industrial manufacturing plants is utilizing a facility Public Address/General Alarm (PA/GA) system.

This type of system serves as a vital link between the operators in the facility’s main control room and personnel who work within the plant in capacities that include system maintenance, engineering, process analysis and site security.

Not only is the PA/GA system used for routine select or zone communication, it also is the primary communication medium used for critical emergency response broadcasting.

G U A R D I A N T E L E C O M

Product and Services Guide

PA/GA — Paging Systems Components

19S E C T I O N

w w w.guardiante le com.comISO-9001:2008 Certification Today's Quality Creates Our Future

PSG

-8.2

.3D

Page 2: Product and Services Guide · amp. 1 amp. 2 amp. 3 a mp. 4 sta nd by vox threshold adjustment power a mp. 1 a2 a3 a4 sta nd by f failure record c current failure f c f c f c f c f

Guardian Telecom's Product and Services Guide Catalogue is a compilation of individual Category Sections. They include an in-depth selection of Product Data Sheets from our extensive product lines including Analog and VoIP Telephones, Page/Talk, Cable, Talk/Back, PA/GA equipment, Acoustic Booths, Loudspeakers & Ringers and Accessories at the date of publication.

Based on a policy of continuous improvement, Guardian is constantly evaluating and redesigning existing models, adding new features and introducing new products to the benefit of our customers. Additional information can be found on our website at www.guardiantelecom.com.

Visit industrial sites around the world and you can find telephones and communication systems designed, manufactured, distributed and commissioned by Guardian Telecom. From certified and ruggedized telephone and paging endpoints, to loudspeakers & ringers, cable, accessories, acoustic booths and much more. Our product line is extensive and our knowledge in-depth.

Guardian manufactures and assembles at our modern, ISO certified, CSA, UL and ATEX approved facility located east of the Canadian Rockies in Calgary, Alberta, Canada.

Working closely with our customers has always been a cornerstone in our work ethic. It keeps us up to date on their evolving needs and requirements as they operate in a demanding and uncompromising industrial world.

Guardian Telecom has completed its initial VoIP telephone product launch. As the IP world continues to evolve and grow, we will continue to invest both time and resources in design and testing to meet the stringent requirements that clients demand.

The in-house channel-partner sales and technical teams are here to work directly with you or through our network of distributors and representatives, locally, nationally and globally. Take advantage of their practical experience and product knowledge to make informed decisions based on your communication needs, environmental factors, regulatory requirements, budget considerations, growth and scheduling.

From individual telephone units to complete systems, our focus on customers’ distinct needs is also addressed by customizing products whenever practical. From features to colors, finishes to labels, graphics, parts, enclosures and more.

Guardian can help guide you through the product selection process no matter how complex it is. We invite you to contact us to discuss your needs and see if our products & services will be the right fit.

Toll free (North America) 1 800 363-8010 Tel 403 258-3100 Fax 403 253-4967 E-mail [email protected]

19-i

Guardian Telecom Product and Services Guide www.guardiantelecom.com PSG-8.2.3D

Page 3: Product and Services Guide · amp. 1 amp. 2 amp. 3 a mp. 4 sta nd by vox threshold adjustment power a mp. 1 a2 a3 a4 sta nd by f failure record c current failure f c f c f c f c f

PA/GA — Paging Systems Components

AG17 – Multi-Tone Alarm Generator Reliable ten-tone generator with user programmable alarm tone, priority, duration and triggering. Works with general alarm and public address systems.

• Two models: Multi-Tone Generator with Relay and Multi-Tone Generator – No Relay

AS12 – Automatic Amplifier SwitchGuardian Telecom’s AS12 Automatic Amplifier Switch continuously monitors amplifier signals and automatically switches to a standby amplifier if one fails. Capable of monitoring four amplifiers simultaneously, the AS12 instantly detects faults, automatically switches to a stand-by and visually indicates amplifier status..

DA388 Distribution AmplifierGuardian Telecom’s DA388 Distribution Amplifier is a line level pre-amplifier for use in public address and alarm systems. As part of the integrated system, the DA388 recognizes audio inputs – telephone access, background music, voice signals and alarm tones – and boosts the signal before distribution. The DA388 is designed to prioritize audio input signals and distribute the signal to multiple power amplifiers without degrading audio quality.

PSCU Paging System Control Unit The custom made Guardian Paging System Control Unit (PSCU) is the main control console that includes Gooseneck Microphone with push-to-talk switch, alarm activation and reset buttons (with indicator lights), indicator lights for Digital Recorder (if system equipped), Pilot Tone Generator, Backup Amplifier status and RF Failure indication. It also contains a built-in page system monitor speaker with respective volume control. The PSCU is remote powered and connected to the main system rack via a 25 conductor cable.

AS-ZS10 Zone Selector Switcher The AS-ZS10 is a high power Zone Selector switcher used in conjunction with a logic control unit such as the Bogen PCM2000. It routes amplified page audio out to 10 selectable zones. Power handling is 1000 Watts per zone. Activated zones are displayed by front-mounted LEDs.

19-ii

19-5

19-7

19-9

19-3

19-1

Guardian Telecom Product and Services Guide — PA/GA www.guardiantelecom.com

Page 4: Product and Services Guide · amp. 1 amp. 2 amp. 3 a mp. 4 sta nd by vox threshold adjustment power a mp. 1 a2 a3 a4 sta nd by f failure record c current failure f c f c f c f c f

19-iii

Guardian Telecom Product and Services Guide www.guardiantelecom.com PSG-8.2.3D

Page 5: Product and Services Guide · amp. 1 amp. 2 amp. 3 a mp. 4 sta nd by vox threshold adjustment power a mp. 1 a2 a3 a4 sta nd by f failure record c current failure f c f c f c f c f

AG17Multi-Tone Alarm Generator

FEATURES and BENEFITS•Tentonealarmlibrary•Userprogrammablemicroprocessortocustomizetonepriority,duration,triggering,mutingandattenuation

•Eightchannelsforoutputsignalpriority•Logicoutputmirrorscontrolinputs•Momentaryorlatchinginputs•120/230VAC•LEDalarmactivationindicators•Outputlevelcontrol•Compact−fitsonastandard19”equipmentrack−2rackunits(2U)•AudiooverrideforPage/Talkannouncements

APPLICATIONSThisproductisdesignedforuseinindustrialenvironmentssuchas:•Mines •GrainProcessingandSimilarIndustries•ChemicalPlants •PowerGenerationFacilities•Refineries •FertilizerPlants•DrillingRigs •FoodProcessingPlants•DefenseInstallations •SewagePlants•CementPlants •ConstructionSites•BulkLoadingStations •Breweries&Distilleries•Pulp&PaperMills •PharmaceuticalPlantsandmore...

INSTALLATIONandCONNECTABILITYTheAG17multi-ToneAlarmGeneratorisonecomponentinGuardianTelecom’sfulllineofreliable,hardworkingpagingsystemproducts−alldesignedforeasyinstallationandconnectability.

Overrideaudio/logicinputshaveahigherprioritythanalarmtonesignalsandsuppressanyexistingalarmtonetobroadcasttheoverride.Anactivealarmcanbecompletelymutedorattenuatedby10dB,20dB,or60dBtoaccommodateanoverridebroadcast.

TheAG17canbeorderedseparatelyoraspartofanintegratedsystemthatincludesPage/Talkstations,speakersandspeakeramplifierunits,anddistributionamplifiers.Guardian’strainedrepresentativeswillworkwithyoutocustomizeyouroperation’sgeneralalarmandpagingsystems.

TheGuardianTelecomAG17isareliableten-tonesignalgeneratordesignedtoworkwithyourgeneralalarmandpublicaddresssystems.Alarmtone,priority,durationandtriggeringarealluserprogrammabletomeetspecificoperatingsafety,andworkplaceconditions.AnAudiooverridefacilityalsoallowsvoice-pagingduringtoneactivation,givingyoutheabilitytodelivervoiceinstructionsthroughPage/Talkintercomstationsorotherpagingsourcesbycompletelymutingorattenuatingtheactivetone.

AG17

ISO-9001:2008 Certification Today's Quality Creates Our Future

19-1

16-5

Page 6: Product and Services Guide · amp. 1 amp. 2 amp. 3 a mp. 4 sta nd by vox threshold adjustment power a mp. 1 a2 a3 a4 sta nd by f failure record c current failure f c f c f c f c f

Distributed by:

ISO-9001:2008 Certification Today's Quality Creates Our Future

Guardian pursues a policy of continuous improvement, therefore specifications are subject to change without notice.

Calgary,Alberta,CanadaTelephone:403258-3100Facsimile:403253-4967

1-800-363-8010(NorthAmerica)[email protected]

AG17 140918

18.2"[464mm]

19.0"[483mm]

Front View

Rear View

Top View

Side View

16.5"[419mm]

3.5"[8

9mm]

8.2"[2

07mm]

3.0"[7

6mm]

OUPUTA L

OUPUTA L

F ESU

FE S U

ALARM LOGIC IN

1 2 3 4 5 6 7 8 C C

ALARM LOGIC OUT

1 2 3 4 5 6 7 8 C C + - + -

VOLUME

+ - + -

O/P I/P

21 43 65 87

A B C A B C A B C A B C A B C A B C A B C A B C

ALARM RELAY CONTACTS

CLEAR RESET

+ - + -

INPUT / OUTPUT

A — AUDIOL LOGIC

RELAY CONTACTSA — NORMALLY OPENB — COMMONC — NORMALLY CLOSED

110 VAC

FUSE 1/2A

RESETCLEAR

POWER

A L A R M S

51 2 3 6 7 84

ENGINEERINGSPECIFICATIONSELECTRICAL REQUIREMENTSInput Supply Voltage 120/230 VACMaximum Current Consumption 12 VAFuse 1/2 A; 250 V; Fast-Blow

AUDIO PERFORMANCEAudio OutputMaximum Voltage ( Adjustable ) Output 1,500 mVImpedance 20 K Ohms Unbalanced

LOGIC PERFORMANCELogic InputsControl Input Enable Open Drain Logic InputRecommended Activating Devices Dry Contact RelaysMinimum Open Collector/Open Drain Output 12VDC @ 100 Micro Amperes

Logic OutputsMaximum Open Drain Output 40VDC @ 300 mA

MECHANICAL SPECIFICATIONSBody Construction 16 Ga Mild SteelNet Weight 12.1 lbs ( 5.5 kg )Shipping Weight 14.0 lbs ( 6.4 kg )Shipping Dimensions ( L x W x D ) 20.0“ x 15.0” x 11.5” ( 508 x 381 x 293mm )Connection Audio Removable Connection PlugConnection Logic Removable Connection Plug

ORDERING INFORMATION Warranty: One year parts and labor

Order No. DescriptionP5960 AG17 Multi-Tone Alarm GeneratorP5970 AG17 Multi-Tone Alarm Generator - No Relay

OVERALLDIMENSIONS

AG17 Multi-Tone Alarm Generator

19-2

16-6

Page 7: Product and Services Guide · amp. 1 amp. 2 amp. 3 a mp. 4 sta nd by vox threshold adjustment power a mp. 1 a2 a3 a4 sta nd by f failure record c current failure f c f c f c f c f

AS12Automatic Amplifier Switch

FEATURES and BENEFITS• Simultaneously monitors up to four paging amplifiers to integrate

one stand-by amplifier• Instantly detects and indicates amplifier failure• Automatically transfers output from a failed amplifier to the

stand-by amplifier• Visually indicates amplifier status• Maintains historical visual indicators• Automatically resets amplifiers to normal once a fault is corrected• Suitable for 70 volt audio amplifiers up to 1200 watts• Compact – fits on standard 19” equipment rack

APPLICATIONSThis product is designed for use in industrial environments such as:

• Mines • Grain Processing and Similar Industries• Chemical Plants • Power Generation Facilities• Refineries • Fertilizer Plants• Drilling Rigs • Food Processing Plants• Defense Installations • Sewage Plants• Cement Plants • Construction Sites• Bulk Loading Stations • Breweries & Distilleries• Pulp & Paper Mills • Pharmaceutical Plants and more . . .

INSTALLATION and CONNECTABILITYThe AS12 Automatic Amplifier Switch is one component in Guardian Telecom’s full line of reliable, hard working paging system products – all designed for easy installation and connectability. The AS12 can be ordered separately or as part of an integrated system that includes distribution amplifier, amplifiers and multi-tone alarm generator. Guardian’s trained representatives will work with you to customize a safe comprehensive alarm and public address system for your operations.

Guardian Telecom’s AS12 Automatic Amplifier Switch continuously monitors amplifier signals and automatically switches to a standby amplifier if one fails. Capable of monitoring four amplifiers simultaneously, the AS12 instantly detects faults, automatically switches to a stand-by and visually indicates amplifier status.

Clearly visible LED’s on the front panel indicate the status of each amplifier so any fault can be quickly identified and corrected. The AS12 also maintains historical visual indicators for tracking the amplifier failure.

As a part of an integrated industrial emergency/communications system, the AS12 ensures uninterrupted communication in the event of an amplifier failure.

AS12 Automatic Amplifier Switch

ISO-9001:2008 Certification Today's Quality Creates Our Future

19-3

Page 8: Product and Services Guide · amp. 1 amp. 2 amp. 3 a mp. 4 sta nd by vox threshold adjustment power a mp. 1 a2 a3 a4 sta nd by f failure record c current failure f c f c f c f c f

Distributed by:

ISO-9001:2008 Certification Today's Quality Creates Our Future

Guardian pursues a policy of continuous improvement, therefore specifications are subject to change without notice.

Calgary, Alberta, CanadaTelephone: 403 258-3100 Facsimile: 403 253-4967

1-800-363-8010 (North America)[email protected]

110 VAC

POWER

F U S EF U S E

FUSE

FUSE 1/2 A

AMP. 1 AMP. 2 AMP. 3 AMP. 4 STAND BYVOX THRESHOLD ADJUSTMENT

POWER AMP. 1 AMP. 2 AMP. 3 AMP. 4 STAND BY

F FAILURE RECORDC CURRENT FAILURE

FC

FC

FC

FC

FC

SPKROUTPUT

FROM BACKUPAMP.

FROMAMP. 4

CHANNEL 4

SPKROUTPUT

FROMAMP. 3

CHANNEL 3

SPKROUTPUT

FROMAMP. 2

CHANNEL 2

SPKROUTPUT

FROMAMP. 1

CHANNEL 1

VOXLOGIC INPUT

1 2 3 4 5 C

AMP. FAILURE LOGIC OUTPUT

1 2 3 4 5 C

16.5” [419mm]

19.0” [483mm]

18.2” [464mm]

12.3

” [31

3mm

]

Side View

Top View

Front View Rear View

2.3”

[57m

m]

4.9”

[123

mm

]

5.3”

[133

mm

]

AS12 140919

ENGINEERING SPECIFICATIONSELECTRICAL REQUIREMENTSInput Supply Voltage 120/230 VACMaximum Current Consumption 12 VAFuse 0.5 A @ 120 VAC 0.25 A @ 250 VAC

AUDIO PERFORMANCEAudio Inputs

Maximum Power 1200 Watts @ 70 V

Audio OutputsMaximum Power 1200 Watts @ 70 V

LOGIC PERFORMANCELogic Inputs

Logic Input Enable Connect to GroundLogic Input Disable Leave OpenRecommended Activating Devices Dry Contact RelaysMinimum Open Collector/Open Drain Current Capacity 100 mA

Logic OutputsNormal Open Drain Output OpenFailure Open Drain Output ClosedMaximum Open Drain Output 40 VDC, 1A Maximum

AUDIO MONITOR CIRCUITResponse Bandwidth 200Hz -8 KHzMinimum Activating Input 1 VRMSAmplifier Fail Delay 600 mS

MECHANICAL SPECIFICATIONSBody Construction 16 Ga SteelFace Plate Construction 10 Ga SteelBody Dimensions ( H x W x D ) 4.9” x 16.5” x 12.3” ( 123 x 419 x 313 mm )Face Plate Dimensions 19“ x 5.3” ( 483 x 133 mm ) EIA Standard 3 Rack Unit Net Weight 14 lbs ( 6.4 kg )Shipping Weight 16.0 lbs ( 7.3 kg )Shipping Dimensions ( L x W x D ) 20.0” x 15.0” x 11.5” ( 508 x 381 x 293 mm ) Mounting EIA Rack MountConnecting Audio and Logic Curtis GFTX - W8Paint Epoxy Powder Coat

ORDERING INFORMATION Warranty: One year parts and labor

Order No. DescriptionP8300 AS12 Automatic Amplifier Switch

OVERALL DIMENSIONS

AS12 Automatic Amplifier Switch

19-4

Page 9: Product and Services Guide · amp. 1 amp. 2 amp. 3 a mp. 4 sta nd by vox threshold adjustment power a mp. 1 a2 a3 a4 sta nd by f failure record c current failure f c f c f c f c f

DA388Distribution Amplifier

FEATURES and BENEFITS•Linelevelpre-amplifier•Allowsconnectionoflowlevelaudiosignalstomultipleamplifiers•Maintainssignalquality•Distributessignalstomultiplepoweramplifiers•Assignsprioritiestoaudioinputsignals•Useslogiccontroltoswitchaudioinputstoselectedaudiooutputs•OutputsignalsgenerateaVOXlogicoutputsignal•Twoaudiooutputsmirrorthehighestpriorityaudioinputs•LEDstatusindicators•Internalvolumeadjustmentsforeachinputandoutput•Compact–19”(483mm)rackmount•IdealforusewithGuardianTelecomAS12AutomaticAmplifierSwitch

APPLICATIONSThisproductisdesignedforuseinindustrialenvironmentssuchas:

•Mines •GrainProcessingandSimilarIndustries•ChemicalPlants •PowerGenerationFacilities•Refineries •FertilizerPlants•DrillingRigs •FoodProcessingPlants•DefenseInstallations •SewagePlants•CementPlants •ConstructionSites•BulkLoadingStations •Breweries&Distilleries•Pulp&PaperMills •PharmaceuticalPlantsandmore...

INSTALLATIONandCONNECTABILITYTheDA388isonecomponentinGuardianTelecom’sfulllineofreliable,hardworkingpagingsystemproducts–alldesignedforeasyinstallationandconnectability.TheDA388canbeorderedseparatelyoraspartofanintegratedsystemthatincludesamplifiers,automaticamplifierswitchandmulti-tonealarmgenerator.Guardian’strainedrepresentativeswillworkwithyoutocustomizeasafecomprehensivealarmandpublicaddresssystemforyouroperations.

GuardianTelecom’sDA388DistributionAmplifierisalinelevelpre-amplifierforuseinpublicaddressandalarmsystems.Aspartoftheintegratedsystem,theDA388recognizesaudioinputs–telephoneaccess,backgroundmusic,voicesignalsandalarmtones–andbooststhesignalbeforedistribution.TheDA388isdesignedtoprioritizeaudioinputsignalsanddistributethesignaltomultiplepoweramplifierswithoutdegradingaudioquality.

TheDA388hasthreeaudioinputstofacilitatetelephone,tuner,tape,CDplayer,orotherpageinputsources.AllinputshaveindividualvolumecontrolsforbalancinglevelsintotheDA388.Thehighestpriorityaudioinputiscontrolledbyasinglelogicinput.Twooftheaudioinputsarecontrolledbyeightlogicinputsgivingyoutheflexibilitytoselectasingleoutputoracombinationofoutputsfortheaudiosignal.

OutputsontheDA388provideacombinationofexternalandinternalcontrolsandarevolumeadjustable.EachoftheeightexternallycontrolledoutputsgeneratesaVOXlogicoutputsignal.ThresholdadjustmentsdeterminetheminimumaudiolevelnecessarytoturnVOXlogiconandoff.

DA388DistributionAmplifier

ISO-9001:2008 Certification Today's Quality Creates Our Future

19-5

Page 10: Product and Services Guide · amp. 1 amp. 2 amp. 3 a mp. 4 sta nd by vox threshold adjustment power a mp. 1 a2 a3 a4 sta nd by f failure record c current failure f c f c f c f c f

Distributed by:

ISO-9001:2008 Certification Today's Quality Creates Our Future

Guardian pursues a policy of continuous improvement, therefore specifications are subject to change without notice.

Calgary,Alberta,CanadaTelephone:403258-3100Facsimile:403253-4967

1-800-363-8010(NorthAmerica)[email protected]

DA388 140919

ENGINEERINGSPECIFICATIONSELECTRICAL REQUIREMENTSInput Supply Voltage 120/230 VACMaximum Current Consumption 250 MAFuse 0.5A @ 120 VAC 0.25 @ 250 VAC

AUDIO PERFORMANCEAudio InputsChannel One

Maximum Voltage 1 V RMSInput Impedance 600 Ohms Balance

Channels Two & ThreeMaximum Voltage 650 mV RMS Input Impedance 10K Ohms Balance

Audio OutputsWith External Control 8 OutputsWith Internal Control 2 OutputsMaximum Voltage 1,700 mVInput Impedance 10K Ohms Balance

LOGIC PERFORMANCELogic Inputs

Channel 1 One 5 V TTL Logic - Controls All Audio OutputChannels 2 & 3 Eight 5 V TTL Logic - One Logic Control per OutletRecommended Activating Devices Dry Contact Relays, Open Collector Output, or Open Drain Output Devices

Logic outputsVOX Controlled Eight Open DrainInput Control One Open Collector, Input Controlled from Channels 1 and 2

MECHANICAL SPECIFICATIONSBody Construction 16 Ga SteelFace Plate Construction 10 Ga SteelBody Dimensions ( H x W x D ) 4.9 “ x 16.5” x 12.3” ( 123 x 419 x 313 mm )Face Plate Dimensions 19“ x 5.3” ( 483 x 133 mm )EIA Standard 3 Rack UnitNet Weight 14.0 lbs ( 6.4 kg )Shipping Weight 16.0 lbs ( 7.3 kg )Shipping Dimensions ( L x W x D ) 20.0” x 15.0” x 11.5” ( 508 x 381 x 293 mm ) Mounting EIA Rack MountConnecting Audio and Logic Phenonix Mini-combicon Logix OB-9Paint Epoxy Powder Coat

110 VAC

POWER

F U S EF U S E

FUSE

AUDIO INPUTS

AUDIO OUTPUTS

LOGIC INPUTS

LOGIC OUTPUTS

A B C B C A C

A C

B C

FUSE 1/2 A1234C 5678C1234C 5678C

1 2 3 4 B1 5 6 7 8 B2 VOX 1 - 41 2 3 4 C

VOX 5 - 85 6 7 8 C

VOX THRESHOLD MONITOR

54321 876POWER

16.5”[419mm]

19.0”[483mm]

18.2”[464mm]

12.3”[31

3mm]

Side View

Top View

Front View Rear View

2.3”[5

7mm]

4.9”[1

23mm]

5.3”[1

33mm]

ORDERING INFORMATION Warranty: One year parts and labor

Order No. DescriptionP8200 DA388 Distribution Amplifier

OVERALLDIMENSIONS

DA388 Distribution Amplifier

19-6

Page 11: Product and Services Guide · amp. 1 amp. 2 amp. 3 a mp. 4 sta nd by vox threshold adjustment power a mp. 1 a2 a3 a4 sta nd by f failure record c current failure f c f c f c f c f

Distributed by:

Calgary, Alberta, Canada 1-800-363-8010 (North America) Tel: 403 258-3100 Fax: 403 253-4967 [email protected] www.guardiantelecom.com

Guardian pursues a policy of continuous improvement, therefore specifications are subject to change without notice.

ISO-9001:2008 Certification Today's Quality Creates Our Future

The PSCU can be customconfigured depending on a customer’s specific system requirements.

The custom made Guardian Paging System Control Unit (PSCU) is a PA/GA system main control console that includes a Gooseneck Microphone with Push-to-Page switch, alarm activation and reset buttons (with indicator lights), for other system rack components.

It also contains a built-in page system monitor speaker with respective volume control. The PSCU is remote powered and connected to the main system rack via a multi-conductor cable.

PSCUPaging System Control UnitFEATURES and BENEFITS•16gaugesteelenclosure-zincdichromateplatedand

powder coated•10gaugesteelfaceplate-zincdichromateplatedand

powder coated•Heavydutygooseneckmicrophone•Ergonomicangledtopdeck•Multi-alarmchannelactivationbuttonsplusoneresetbutton•PAsystemmonitoringcapability•Monitorspeakervolumecontrol•Remotedeviceindicationformainsystemrackunitstatus•Quickdisconnectwiringharness•LargePush-to-Page(PTP)button•Internaltelephone(RJ11)jacksforoptional telephone termination•Selectablemonitorspeakermuting

APPLICATIONSGuardian’s PSCU Paging System Control Unit can be used on customizedGuardianPA/GAracksystemsorthird-partyPA/GArack systems. The PSCU can be custom configured depending on a customers’ specific system requirements.

INSTALLATIONandCONNECTABILITY•DB25connector

PSCU 140919

ISO-9001:2008 Certification Today's Quality Creates Our Future

19-7

Page 12: Product and Services Guide · amp. 1 amp. 2 amp. 3 a mp. 4 sta nd by vox threshold adjustment power a mp. 1 a2 a3 a4 sta nd by f failure record c current failure f c f c f c f c f

19-8

Page 13: Product and Services Guide · amp. 1 amp. 2 amp. 3 a mp. 4 sta nd by vox threshold adjustment power a mp. 1 a2 a3 a4 sta nd by f failure record c current failure f c f c f c f c f

The AS-ZS10 Zone Selector is a high power switching unit used that is used in conjunction with a logic control unit such as the Bogen PCM2000. It routes amplified page audio out to 10 selectable zones. Power handling is 1000 Watts per zone. Activated zones are displayed by front-mounted LEDs.

AS-ZS10Zone Selector

FEATURES and BENEFITS•16gaugesteelenclosure–zincdichromateplated

and powder coated•10gaugesteelfaceplate–zincdichromateplated

and powder coated•Compact19”rackmount–threerackunits(3U)•FrontmountedzonestatusindicatorLEDs•1000Wattpowerhandling(perzone)•10zoneswitchingcapable

APPLICATIONS•Mines •GrainProcessingPlants•ChemicalPlants •PowerGenerationFacilities•Refineries •FertilizerPlants•DrillingRigs •FoodProcessingPlants•SewagePlants •DefenseInstallations•CementPlants •ConstructionSites•BulkLoadingStations •Breweries&Distilleries•Pulp&PaperMills •PharmaceuticalPlantsand more . . .

INSTALLATION and CONNECTABILITYTheAS-ZS10ZoneSelectorisonecomponentinGuardianTelecom’sfulllineofreliable,hardworkingpagingsystemproducts — all designed for easy installation and connectability. The AS-ZS10 can be ordered separately or as part of an integrated system that includes distribution amplifier, amplifiers and multi-tonealarmgenerator.Guardian’strainedrepresentativeswillworkwithyoutocustomizeasafecomprehensivealarmand public address system for your operations.ISO-9001:2008 Certification

Today's Quality Creates Our Future

19-9

Page 14: Product and Services Guide · amp. 1 amp. 2 amp. 3 a mp. 4 sta nd by vox threshold adjustment power a mp. 1 a2 a3 a4 sta nd by f failure record c current failure f c f c f c f c f

Distributed by:

ISO-9001:2008 Certification Today's Quality Creates Our Future

Guardian pursues a policy of continuous improvement, therefore specifications are subject to change without notice.

Calgary, Alberta, CanadaTelephone:403258-3100Facsimile:403253-4967

1-800-363-8010(NorthAmerica)[email protected]

ASZS10 140919

ENGINEERINGSPECIFICATIONSELECTRICAL SPECIFICATIONSInput Supply Voltage 120/230 VACFuse 0.5 Amp 250 VAC, Type 3Ag Fast Blow

Logic InputsTen Logic Inputs Activated by Dry Contact, Open Drain, or Open Collector Switches Capable of Handling Minimum 10mA

Audio InputsTen Page Lines 70 / 100 V, 1000 W Maximum

Audio OutputsTen Page Lines 70 / 100 V, 1000 W Maximum

DisplaysPower On LED Ten Zone Activated LEDs

MECHANICAL SPECIFICATIONSBody Construction 16 Ga SteelFace Plate Construction 10 Ga SteelBody Dimensions ( H x W x D ) 4.9” x 16.5” x 12.3” ( 123 x 419 x 313 mm )Face Plate Dimensions 19” x 5.2” ( 483 x 133 mm )Shipping Dimensions ( L x W x D ) 20.0” x 15.0” x 11.5“ ( 508 x 381 x 293 mm )Connecting Audio and Logic Screw TerminalsPaint Epoxy Powder Coat

POWER ON

ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8 ZONE 9 ZONE 10

ZONE 1ZONE 2ZONE 3ZONE 4ZONE 5ZONE 6ZONE 7ZONE 8ZONE 9ZONE 10

AUDIOIN

AUDIOOUT

AUDIOIN

AUDIOOUT

ZONESELECT

ZONESELECT

AUDIOIN

AUDIOOUT

ZONESELECT

AUDIOIN

AUDIOOUT

ZONESELECT

POWER

FUSE 1/2 A

220VAC

AUDIOIN

AUDIOOUT

ZONESELECT

AUDIOIN

AUDIOOUT

ZONESELECT

AUDIOIN

AUDIOOUT

ZONESELECT

AUDIOIN

AUDIOOUT

ZONESELECT

AUDIOIN

AUDIOOUT

ZONESELECT

AUDIOIN

AUDIOOUT

ZONESELECT

Rear View

Side View

Front View

Top View

4.9”[1

23mm]

2.3”[5

7mm]

5.3”[1

33mm]

16.5”[419mm]

16.5”[419mm]

18.2”[464mm]

19.0”[483mm]

ORDERING INFORMATION Warranty: One year parts and labor

Order No. DescriptionP9004 AS-ZS10 Zone Selector

OVERALL DIMENSIONS

AS-ZS10 Zone Selector

19-10

Page 15: Product and Services Guide · amp. 1 amp. 2 amp. 3 a mp. 4 sta nd by vox threshold adjustment power a mp. 1 a2 a3 a4 sta nd by f failure record c current failure f c f c f c f c f

Sections Guardian Telecom’s Product and Services Guide Catalogue is a compilation of individual Category Section Publications

Page/TalkExplosion Proof 13

Stations 14

System Cable 15

System Components 16

Page Station Module ReplacementsPage/Party® Module Replacements 1

17

Page/Talk Module Replacements

17

Talk/Back Explosion Proof Amplifier

18

Multi-Channel Amplifiers

18

PA/GASystem Components 19

Acoustic BoothsAluminum & GRP 20

Loudspeakers/RingersExplosion Proof 21

Hazardous Area 22

ATEX-IEC 23

General Area 24

Guardian represents DNH, E2S, Federal Signal, MEDC and TOA, and has access to an extensive range of other world class leading manufacturers. Visit www.guardiantelecom.com for additional information on Explosion Proof, Hazardous Area, ATEX-IEC and General Area Loudspeakers & Ringers.

Accessories & EnclosuresTelephone Accessories & Enclosures

25

Page/Talk Accessories 26

Product IndexPart No., Description, Product Section & Product Data Sheet 27

Guardian 1

About Guardian TelecomBuilding on a Legacy of Design and Service•Communications: Easy, Reliable and Safe•More Choices, Selections and Services•Standard Features•Options & Accessories •Product and Project Consultation•Commissioning Services•Sound Studies•Training•Maintenance, Cleaning, Trouble Shooting & Refurbishment•Custom Design•Page/Talk, Telephone, PA/GA and Talk/Back Systems •Standards and Classifications•

Knowledge Base Glossary

ProductsAnalog Telephones

Explosion Proof 2

ATEX-IEC 3

Hazardous Area 4

Outdoor Industrial 5

Indoor Industrial 6

Emergency/Help Point 7

Correctional 8

VoIP TelephonesHazardous Area VoIP

9

Outdoor Industrial VoIP

10

Indoor Industrial VoIP

11

Emergency/ Help Point VoIP

12

1 Page/Party® is a registered trademark of GAI-Tronics Inc. Use does not imply endorsement.

Guardian Telecom Product and Services Guide — Table of Contents www.guardiantelecom.com PSG-8.2.3D

Page 16: Product and Services Guide · amp. 1 amp. 2 amp. 3 a mp. 4 sta nd by vox threshold adjustment power a mp. 1 a2 a3 a4 sta nd by f failure record c current failure f c f c f c f c f

Calgary, Alberta, CanadaTelephone: 403 258-3100 Facsimile: 403 253-49671-800-363-8010 (North America)[email protected]

Canada USA Middle East

All content including the "Guardian Telecom" logo, images, graphics and descriptions are not to be used without the expressed written authorization of Guardian Telecom Inc., Calgary, Alberta, Canada. All other names and logos are the trademarks or registered trademarks of their respective companies.

Guardian pursues a policy of continuous improvement, therefore product, content and specifications are subject to change without notice. Design, specifications and release dates are subject to change without notice.

Guardian Telecom Product and Services Guide www.guardiantelecom.com PSG-8.2.3D