18/02/2015 Procedure for Starting and Stopping of Sewage Treatment Plant on a Ship http://www.marineinsight.com/tech/proceduresmaintenance/procedureforstartingandstoppingofsewagetreatmentplantonaship/ 1/14 Search Marine Insight Facebook 28 Twitter Google+ LinkedIn Pinterest LEAVE A COMM Procedure for Starting and Stopping of Sewage Treatment Plant on a Ship OCTOBER 24, 2010 BY MOHIT Any machine on the ship requires a proper procedure to be followed for starting and stopping Failure to follow this stepbystep procedure will lead to either failure in starting or stopping th machine or lead to some fault. Forums Photos Videos Premium eBooks Free eBooks HOME NEWS MARINE TECH NAVIGATION SAFETY CAREER LIFE AT SEA NAVAL ARCH PIRACY REPORTS
14
Embed
Procedure for Starting and Stopping of Sewage Treatment Plant on a Ship
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
18/02/2015 Procedure for Starting and Stopping of Sewage Treatment Plant on a Ship
Procedure for Starting and Stopping ofSewage Treatment Plant on a Ship
OCTOBER 24, 2010 BY MOHIT
Any machine on the ship requires a proper procedure to be followed for starting and stopping it.Failure to follow this stepbystep procedure will lead to either failure in starting or stopping themachine or lead to some fault.
Sewage treatment plant is one such equipment on the ship which requires a stepbystepprocedure to be followed for starting and stopping it. In this article we will go through the procedureof starting and stopping a sewage treatment plant.
Starting of a Sewage Plant
Sewage plant is generally running all the time during sailing, but it might need to be started whenthe ship is installed with a new sewage treat plant which needs to be stopped at regular interval oftime for improving its performance and maintenance procedures. Below are the points that need tobe followed for starting a sewage treatment plant.
1. Make sure if any maintenance is carried out on the sewage treatment system, all the openingshave been closed properly before starting.
2. The sewage plant is be filled with fresh water inside the chamber.
3. At this stage, there are no aerobic bacteria inside the chamber, but the sewage has startedcoming to the plant. Thus, in order to increase efficiency and starting rate of the plant bio pac isadded to the plant by flushing the amount specified in the manual. This bio pac is mixed withwarm water which helps in growth of these bacteria and also efficient functioning of the plant.
4. If the bio pac is not added, the plant might take up to 5 to 7 days to be completely functional.However, with the bio pac it becomes functional within 24 hours.
5. Start the air compressor or open the air valve as per the design of the plant. The pressure ismaintained as per the manual. Generally 0.30.4 bars.
SludgeTreatment
Filter, bridges, classifiers Weprotect the environment
18/02/2015 Procedure for Starting and Stopping of Sewage Treatment Plant on a Ship
6. Open the sewage overboard valve and close holding tank valve when the ship is out ofrestricted waters.
7. The plant is continuously monitored and checked for the flow through the transparent plastictubes.
8. The sample is taken for checking for suspended solids and chlorine content.
Stopping of the plant
Stopping of the sewage treatment plant is generally done either before entering the dry dock or incase some maintenance has to be carried out inside the treatment plant.
1. For stopping the system, close the inlet valve to the sewage plant and close the overboard valveand let the sewage go overboard.
2. Empty all the three chambers of the plant i.e. aeration, settling and chlorination chambers. If thechambers are not emptied, it will lead to growth of anaerobic bacteria which forms the toxic H2Sgas.
3. If entry has to be made inside the tank, the later should be checked for hydrogen sulphide gasH2S with the help of dragor tube by taking a continuous sample from the plant. Entry is made withthe help of mask and rubber gloves should be put on.
Like It? Share It Share on Facebook Share on Twitter
Enter Your Best Email
4. In case the ship is going to dry dock the overboard should be connected to shore receptionfacilities.
Image Credits: marineplantssytems