Page 1: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Problem Statement

Analysis of Chemical Heat Pump

Analysis of Cooling Tower

Analysis of Boiler

Page 2: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Flash tank

Heat exchangerExothermicreactor

Distillation column

endo reactor

Flash tankH2Acetone2-Propanol

H2

condenser

MIXED

Acetone

H2

Acetone2-prop

Compressor 1

Pump 1

Compressor 2

Liquid

gas

Reduction valve

water

Hot airCool air

Pump 2

Air 79 % N2 21 % O2

Natural gas

Combustion gassesCO2, H2O, N2, O2T= 375 F

BFW

SS

CR

BOILER

reboiler

Cooling tower

Ambient air85 F80 % RH

CWR 103 F

Exit air

Pump 3

CWS 75 F

COOLING TOWER

MOCSWORKING DIAGRAMPBL-7-98

WATER

2- prop & acetone

Page 3: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Given: Chemical Heat Pump

Diameter of L1 = 6.35 mm

Average Velocity = 10 m/sec

Temperature L6 = 200 C

Mole composition of L1= .97 2-Propanol

Mole composition of L5= .02 2-Propanol

Page 4: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Given: Chemical Heat Pump (continued)

Hot Air going into Endo 23.8 C

Relative Humidity 80 %

Cool Air coming out of Endo 15.5 C

Page 5: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Required: Chemical Heat Pump

Energy Supplied into Endo Reactor (Qin)

Diameter of L6

Partial Pressures of L6

Amount of Water Condensed in Endo

Page 6: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Endo Reactor

Q in

Hot air

Nextpage

L 202

L 2

L 201

Acetone2- Prop

L 3Condenser

L 5

L 4

L 803

Water

Cool air

L 303

Pump 2

L 1L 101

H2

Re-boiler

Reduction valve

Acetone2-Prop

L 801

CWR

Flash Tank 1

DistillationColumn

Page 7: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Analysis: Chemical Heat Pump (Endo)

Qin = 353000 Btu/ hr (29 ton unit)

Water Condensed 168 lb/hr (21 gal/hr)

Page 8: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Exothermic Reactor

L 202 L 203Compressor 1

L 5Pump 1

ExoReactor

L 6L 501 Acetone

Heat ExchangerL 7

L 802

L 801

Gas

Compressor 2

L 8

L 804

H2

H2

Acetone2-Propanol

Flash Tank 2

H2

Page 9: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Analysis: Exothermic Reactor

Diameter of L6 = 29.0 mm

Partial Pressure: 1.96 ATM Acetone

0.04 ATM 2-Propanol

Page 10: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Given: Cooling Tower

Cold Water Return 39.4 C

Cold Water Supply 23.8 C

Input Ambient Air 29.4 C

Relative Humidity 80 % (Ambient Air)

Exit Air 30.5 C RH 90 %

Page 11: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Given: Cooling Tower (continued)

Diameter for CWS and CWR: 0.05 m

Page 12: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Cooling Tower

CWR103 FCooling

Tower

Ambient Air85 F80 % RH

L 301

L 302

Exit Air

Pump 3

WaterL 303CWS 75 F

Page 13: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Required: Cooling Tower

Velocity for Cold Water Supply

Velocity for Cold Water Return

Pounds of Dry Air from Cooling Tower

Page 14: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Analysis: Cooling Tower

Velocity of Cold Water Supply: 1418.0 m/hr

Velocity of Cold Water Return: 1425.0 m/hr

Pounds of Dry Air: 34,600 lb dry air/ hr

Page 15: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Given: Boiler

Steam Supply 220 psig (q=1)

Cold Return (q=0)

Temperature of Exit Gas 190.5 C

Combustion Gasses: CO2, H2O, N2, O2

Excess Air 40 %

Page 16: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Given: Boiler (continued)

Diameter for SS and CR: .05 m

Page 17: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Boiler

Boiler Feed WaterBoiler

CombustionGassesCO2,H20,N2,O2

L 901L 903

CR

SS

Natural GasAir79 % N221 % O2

T= 375F

L 902

Page 18: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Required: Boiler

Velocity of Steam Supply

Velocity of Cold Return

Flow Rate of Natural Gas

Percent Composition of Exit Gasses

Page 19: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Analysis: Boiler

Velocity Steam Supply: 3960.0 m/hr

Velocity Cold Return: 36.7 m/hr

Amount of Natural Gas: 3.51 tons/month

Page 20: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Analysis: Boiler (continued)

Composition of Flue Gasses:

CO2 = 7.0 %

H20 = 13.9 %

O2 = 5.6 %

N2 = 73.5 %

Page 21: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Differential (Batch) Distillation

Bryan Gipson

John Usher

November 12, 1997

Page 22: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

121110987

654321

Feed Pump

Cooler

Distillate

CoolingWater

CoolingWater

Reboiler

Reboiler Pump

Bottoms

CalrodHeater

Condenser

Heater

Feed

ElectromagneticReflux Control

Cooler

Page 23: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Progress

• Familiarization with System

• 2 Runs Conducted– First Run Inconsistent– Second Run Okay

• Data Taken– Initial Volume: 14 liters– Time vs. Temperature– Rate of Distillation

Page 24: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Differential Distillation

71

71.5

72

72.5

73

73.5

74

74.5

75

0 5 10 15 20 25 30 35t, min

T, d

eg

C

Observed

Theoretical

Page 25: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Observations

• Temperature Change– Less than Predicted

• Rate of Distillation– Observed: Sporadic, ~94 ml/min– Theoretical: Decreasing, 215-200 ml/min

Page 26: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Next Steps

• Resolve Inconsistencies

• Conduct More Data Runs

• Estimate Heat Losses

• Compare Column Performance to Predictions

Page 27: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Differential (Batch) Distillation

Bryan Gipson

John Usher

November 12, 1997

Page 28: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

121110987

654321

Feed Pump

Cooler

Distillate

CoolingWater

CoolingWater

Reboiler

Reboiler Pump

Bottoms

CalrodHeater

Condenser

Heater

Feed

ElectromagneticReflux Control

Cooler

Page 29: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Progress

• Familiarization with System

• 2 Runs Conducted– First Run Inconsistent– Second Run Okay

• Data Taken– Initial Volume: 14 liters– Time vs. Temperature– Rate of Distillation

Page 30: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Differential Distillation

71

71.5

72

72.5

73

73.5

74

74.5

75

0 5 10 15 20 25 30 35t, min

T, d

eg

C

Observed

Theoretical

Page 31: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Observations

• Temperature Change– Less than Predicted

• Rate of Distillation– Observed: Sporadic, ~94 ml/min– Theoretical: Decreasing, 215-200 ml/min

Page 32: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Next Steps

• Resolve Inconsistencies

• Conduct More Data Runs

• Estimate Heat Losses

• Compare Column Performance to Predictions

Page 33: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Distillation ColumnDesign Project

M. O. C. Project Engineering Department

Team Members

Michael Hobbs

Michael McGann

Marc Moss

Brad Parr

Brian Vandagriff

Page 34: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Topics of Discussion

• Problem Statement

• Recommended Design

• McCabe-Thiele Diagram

• Design Specifications

• Combined Flow Diagram

Page 35: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Topics, cont.

• Method of Design

• Raoult Method

• van Laars Method

• Sieve Tray Efficiency

• Optimum Reflux Ratio

• Conclusions

Page 36: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Problem Statement

To design a new ethylene purification column to work with the advanced catalytic cracking operation that produces ethylene for manufacture of specialty products

Page 37: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

PROCESS

AREA B

PROCESS

AREA C

PROCESS

AREA C

EAST AVENUE

WEST AVENUE

BROADWAY

EMPLOYEE PARKING

VISITOR PARKING

OFFICE

T1

T2

T3 T4 FS1

B2

B1

CT1

CT2

T5 T6

CO

LU

MN

ST

RE

ET

ST

RE

ET

3RD

ST

RE

ET

2ND

1ST

DISTILLATE

CWS

SS

Page 38: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Recommended Design

Design analysis included:

• number of trays

• tray diameter

• pipe diameter for each stream

• pump selection (if necessary)

Page 39: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

McCabe-Thiele Diagram

Fortran program “Distil.exe” was used to generate data that was plotted in Excel to give McCabe-Thiele Diagram. Diagram shows equilibrium line, operating line, feed line, separation line, and the stepped off stages.

Page 40: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1

0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1

x

y

Feed tray = 73

Page 41: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Quantity Description Each Cost System81 23.70 ft. diameter Sieve-trays $4,800.00 $388,800.00

107 ft 8-inch diameter pipe (SS) $175.00 $18,593.75 distillate10 ft 3-inch diameter pipe (SS) $58.00 $580.00 bottoms10 ft 16-inch diameter pipe (SS) $310.00 $3,100.00 feed44 ft 18-inch diameter pipe (SS) $390.00 $17,062.50 CWS63 ft 36-inch diameter pipe (SS) $660.00 $41,250.00 SS100 ft 12-inch diameter pipe (SS) $290.00 $29,000.00 reflux

1 Chemical inline ductile iron casing, vertical motor $1,500.00 $1,500.00 bottoms1 Chemical inline ductile iron casing, horiz. motor $1,800.00 $1,800.00 distillate1 AVS Chemical horizontal ductile iron casing $2,100.00 $2,100.00 reflux

Design Specifications

Page 42: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Combined Flow Diagram

Shows system diagram with both qualitative and quantitative information.

Page 43: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

DistillateD = 182 Mlb/hxD = 0.999

Bottoms ProductB = 38 Mlb/hxB = 0.089

Condenser

Splitter

Reboiler

Cold Water Supply = 378.1 Mlb/hT = 80 oF

Steam Supply = 119.7 Mlb/hP = 20 psig

Cold Water ReturnT = 120 oF

Water Return

L = 546 Mlb/h

V’ = 546.5 Mlb/h

L’ = 585.2 Mlb/h

V = 719.5 Mlb/h

FeedF = 220 Mlb/hxF = 0.85f = 1

EM = 80%

81

stages

Page 44: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Design Requirements

• feed : 220 M lb/hr of vapor, 85% ethylene

• product: 182 M lb/hr, 99.9% ethylene

Page 45: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Raoult Model

• Assumes ideal behavior

• System deviated slightly from ideality at low compositions

Page 46: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

0.0

0.2

0.4

0.6

0.8

1.0

0.0 0.2 0.4 0.6 0.8 1.0x

y

Actual Data

Operating Line Equilibrium Line

Page 47: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

van Laars Model

• Assumes all non-ideal behavior in the liquid

• Shows an improved correlation between model and actual data

Page 48: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

0.0

0.2

0.4

0.6

0.8

1.0

0.0 0.2 0.4 0.6 0.8 1.0x

y

Operating Line

Equilibrium Line

Actual Data

Page 49: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Sieve Tray Efficiency

Sieve trays were chosen because they are cheaper, more efficient, and have a larger operating range than other types of tray designs

Page 50: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Fg = Ut g

1/2

Page 51: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Optimum Reflux Ratio

The optimum reflux ratio was determined by calculating the annual operating costs for columns with varying reflux ratios. A plot of annual cost vs. reflux ratio was made; the optimum value is the one that corresponds to the minimum point on the curve.

Page 52: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

2.E+06

3.E+06

3.E+06

4.E+06

4.E+06

5.E+06

2.5 3.0 3.5 4.0 4.5 5.0

Reflux Ratio

Annu

al C

ost,

$

Page 53: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Minimizing Annual CostThree options each were given for heating the reboiler and cooling the condenser.

Heating: steam at 20 psig ($1/1000lb)

steam at 100 psig ($3/1000lb)

electrical heating ($0.12/kWh)

Cooling: cooling water ($0.50/1000gal)

domestic water ($1.80/1000gal)

refrigerant ($5/ton-day)

Page 54: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Minimizing Annual Cost

Total annual costs (based on 7200 hr/yr) were calculated for each of the options. The lowest priced option for each was selected.

• heating: steam at 20 psig

• cooling: CWS

Page 55: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Conclusions

The column designed contains 81 trays, with a diameter of 23.7 ft and 12 inch spacing between the trays. It will require an initial start-up cost of $3.01 million, and a present worth of $17.14 million over a projected 11 year operational life.

Page 56: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Ultimate Tennessee Corn whiskey

Skip Pond, EI

Michael McGann

Page 57: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Topics of Discussion

• Past Accomplishments (Section 200)• Current Work (Section 300)• Next Steps

Page 58: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Revised Problem Statement

• Basis: 500,000 gallons finished product

• Areas of focus– Section 200 (Cooking/Fermenting)– Section 300 (Distillation)– Section 900 (Boiler/Cooling Tower)

Page 59: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Revised Problem Statement

• Customer requirements– Operational Schedule Comparison– Automated Control Investigation– Onsite Boiler/Cooling Tower– Pre-Distillation Settling Tank

• Liquid Feed Column with Flash Tank

Page 60: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Section 200: Cooking/Fermenting

Page 61: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Equipment Specifications

No. Item and Description Size Mat'l Const. 1990 unit cost M&S Purchase Price1 S-211Yeast Dry Storage 5000 gal SS 40,000.00$ 0.122 44,880.00$ 2 T-211-212 Mash Tub w/ Bottom Filter(Cooking) 8500 gal. SS 53,528.00$ 0.122 120,116.83$ 7 T-221-227 Fermentation Tank 20000 gal. SS 45,900.00$ 0.122 360,498.60$

1MP-21 Mash Tub Pump and Motor (3/16 SS Centrifugal) 1000 gpm SS 9,216.00$ 0.122 10,340.35$

Total = 535,835.78$

Equipment Specifications for Section 200 (Cooking and Fermentation)

Page 62: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Mash Tank Material Balance

Inputs

• corn: 259 bushels

• rye: 44.3 bushels

• malt: 37.5 bushels

• H2O: 10000 gal.

*1 bushel = 55 pounds

Outputs

• spent grain: 340.8 bushels

• H2Ovap: 2500 gal.

• wort: 7500 gal.

Page 63: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Mash Cooking Energy Balance

qconvectionT, 132oFqx qx

qx + qconvection=1500000Btu/hr

qwater=11293497 Btu/hr

250psia SteamT=401oFh=1202.1 Btu/hr =25,823 lbs/hr

250psia Condensed SteamT=401oFh = 376.02Btu/hr

Heat Exchanger Coils

m

Page 64: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Operational Schedule

DayTank Mon. Tues. Wed. Thurs. Fri. Sat. Sun.T-211 Cook Mash Cook Mash Cook Mash Cook Mash Cook Mash Cook Mash Cook MashT-212 Cook Mash Cook Mash Cook Mash Cook Mash Cook Mash Cook Mash Cook MashT-221 Fill/Ferm Ferment2 Ferment3 Ferment4 Distill Clean IdleT-222 idle Fill/Ferm Ferment2 Ferment3 Ferment4 Distill CleanT-223 Clean Idle Fill/Ferm Ferment2 Ferment3 Ferment4 DistillT-224 Distill Clean Idle Fill/Ferment Ferment2 Ferment3 Ferment4T-225 Ferment4 Distill Clean Idle Fill/Ferm Ferment2 Ferment3T-226 Ferment3 Ferment4 Distill Clean Idle Fill/Ferm Ferment2T-227 Ferment2 Ferment3 Ferment4 Distill Clean Idle Fill/Ferm

Page 65: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Distillation Column

Page 66: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

DistillateD = 16 klbxD = 0.55

Bottoms ProductB = 13 klbxB = 0.01

Condenser

Splitter

Reboiler

Cold Water Supply =T =

Steam Supply =P =

Cold Water ReturnT =

Water Return

L =

V’=

L’=

V =

FeedF = 147 klbxF = 0.07f = 1

Tray Spacing = 12 in

EM =11

stages

Page 67: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Feed Tray Material Balance

• L’=RD*D + (1-f)*F

• V’=D*(RD+1) - f*F

Page 68: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Condenser Material Balance

• L=RD*D

• V=D*(RD+1)

Page 69: Problem Statement Analysis of Chemical Heat Pump Analysis of Cooling Tower Analysis of Boiler.

Next Steps

• Post Distillation Flash Tank

• Boiler/Cooling Tower Section

• Final cost analysis and reporting