Top Banner
Probing Challenges with Cu Pillar Phill Mai, JEM America Joe Mai, JEM Europe
24

Probing Challenges with Cu Pillar - SWTest.org€¦ · Probing Challenges with Cu Pillar Phill Mai, ... Composite (multi-layer) structure ... • MT probes have high CCC and MAC even

May 15, 2018

Download

Documents

phungngoc
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Probing Challenges with Cu Pillar - SWTest.org€¦ · Probing Challenges with Cu Pillar Phill Mai, ... Composite (multi-layer) structure ... • MT probes have high CCC and MAC even

Probing Challenges with Cu Pillar

Phill Mai, JEM AmericaJoe Mai, JEM Europe

Page 2: Probing Challenges with Cu Pillar - SWTest.org€¦ · Probing Challenges with Cu Pillar Phill Mai, ... Composite (multi-layer) structure ... • MT probes have high CCC and MAC even

Overview• Crown-tip probe limitations• MEMS probe with flat tip• Summary• Future work

2Mai

Page 3: Probing Challenges with Cu Pillar - SWTest.org€¦ · Probing Challenges with Cu Pillar Phill Mai, ... Composite (multi-layer) structure ... • MT probes have high CCC and MAC even

Crown-to-bump contact

3Mai

Piercing Contact Probe mark Abrasive/Gel Cleaning

Page 4: Probing Challenges with Cu Pillar - SWTest.org€¦ · Probing Challenges with Cu Pillar Phill Mai, ... Composite (multi-layer) structure ... • MT probes have high CCC and MAC even

Crown-to-bump CRES stability

4Mai

Cleaning Cycle_TT Sheet

0.0

0.5

1.0

1.5

2.0

2.5

3.0

1 39 77 115

153

191 29 67 105

143

181 19 57 95 133

171 9 47 85 123

161

199 37 75 113

151

189

TD数

抵抗値(Ω

Cleaning Frequency

200 TDs

CRES vs TDS

Touchdowns

Test conditions:• Crown tip dia: φ65 μm• Bump: Pb-free, φ90 x 65 μm• Probing OD: 50 μm from last pin• Cleaning OD: 100 μm from avg. pin height• Frequency: every 200 TDs• Number of TDs/clean: 10• Lateral movement: X390 μm, Y390 μm after each TD • CRES of probe only; test cabling subtracted.

Page 5: Probing Challenges with Cu Pillar - SWTest.org€¦ · Probing Challenges with Cu Pillar Phill Mai, ... Composite (multi-layer) structure ... • MT probes have high CCC and MAC even

Crown-to-Cu pillar contact

5Mai

Slicing Contact Probe mark Abrasive/Gel Cleaning not so effective in the long term

Page 6: Probing Challenges with Cu Pillar - SWTest.org€¦ · Probing Challenges with Cu Pillar Phill Mai, ... Composite (multi-layer) structure ... • MT probes have high CCC and MAC even

Initial Crown-to-Cu pillar CRES stability

6Mai

・Current: 50mA

*CRES includes about 2 ohms of resistance due to PCB, Space transformer, Interposer, and probe body.

RT (30℃) HT (125℃)

200TDCL10TD

200TD

CL10TD CL10TD200TD

LT (-35℃)

Page 7: Probing Challenges with Cu Pillar - SWTest.org€¦ · Probing Challenges with Cu Pillar Phill Mai, ... Composite (multi-layer) structure ... • MT probes have high CCC and MAC even

Long term Crown-to-Cu pillar CRES stability

7Mai

Adhesion of SnAgcauses CRES instabilityafter 50K TDs

Page 8: Probing Challenges with Cu Pillar - SWTest.org€¦ · Probing Challenges with Cu Pillar Phill Mai, ... Composite (multi-layer) structure ... • MT probes have high CCC and MAC even

Crown Tip Contamination with eutectic solder

8Mai

Pb debris remainsBefore laser After laser

Laser: IMT800MVBeam dia.: ~3 mm

In 2007…

Page 9: Probing Challenges with Cu Pillar - SWTest.org€¦ · Probing Challenges with Cu Pillar Phill Mai, ... Composite (multi-layer) structure ... • MT probes have high CCC and MAC even

Crown Tip Contamination with Pb-free solder

9Mai

REF: “Probe Card Cleaning by Laser”, J.M. Lee et.al., SWTW 2010

Before laser After laser

Laser: IMT400PBeam dia.: ~3 mm

In 2016…

Si peak is from cleaning sheet.

Only probe materials

Only probe materials

Page 10: Probing Challenges with Cu Pillar - SWTest.org€¦ · Probing Challenges with Cu Pillar Phill Mai, ... Composite (multi-layer) structure ... • MT probes have high CCC and MAC even

MEMS Technology (MT) as an Alternative

10Mai

Page 11: Probing Challenges with Cu Pillar - SWTest.org€¦ · Probing Challenges with Cu Pillar Phill Mai, ... Composite (multi-layer) structure ... • MT probes have high CCC and MAC even

MT Probe Card Structure

11Mai

Upper guide plate&Upper stiffener plate

Bottom guide plate&Bottom stiffener plateMEMS Probe

PCBStiffener

Interposer(Reflow)

Space transformer

Page 12: Probing Challenges with Cu Pillar - SWTest.org€¦ · Probing Challenges with Cu Pillar Phill Mai, ... Composite (multi-layer) structure ... • MT probes have high CCC and MAC even

MT Probe

12Mai50μm

55μmBefore lateral slide

After lateral slide

Upper guide plate

Bottom guide plate

MT Probe characteristics

◆ Straight probe allows easy assembly and maintenance

◆ Composite (multi-layer) structure optimizes mechanical and electrical properties, and reduces probe wear.

◆ Tip material: Pd alloy

Page 13: Probing Challenges with Cu Pillar - SWTest.org€¦ · Probing Challenges with Cu Pillar Phill Mai, ... Composite (multi-layer) structure ... • MT probes have high CCC and MAC even

MT PROBE MECHANICS

13Mai

Initial OD160μm

recommended OD(from last touch)

Limit OD

Page 14: Probing Challenges with Cu Pillar - SWTest.org€¦ · Probing Challenges with Cu Pillar Phill Mai, ... Composite (multi-layer) structure ... • MT probes have high CCC and MAC even

Guide Plate Selection

14Mai

0

300

600

900

1200

1500

Silicon GuidePlate

Si SiO2 A-484 (Al2O3) SN-240(Si3N4)

[MPa

]Bending Strength

Guide plate A has high bending strength and low friction.

Guide plate A

A B C D E

Guide plate materials

Hardened surface

Hardened surface

Page 15: Probing Challenges with Cu Pillar - SWTest.org€¦ · Probing Challenges with Cu Pillar Phill Mai, ... Composite (multi-layer) structure ... • MT probes have high CCC and MAC even

Probe Force Hysteresis

15Mai

Initial Guide Plate Optimized Guide Plate

Pro

be fo

rce h

ystere

sisD

iffere

nce

SampleDifference

int 1M

N1 0.65gf 2.28gf

N2 0.57gf 1.72gf

Ave. 0.61gf 2.00gf

SampleDifference

int 1M

N1 0.13gf 0.44gf

N2 0.18gf 0.56gf

Ave. 0.16gf 0.50gf

Difference

Probe : 2.5g Contact force version

Difference

Top

Bottom

Page 16: Probing Challenges with Cu Pillar - SWTest.org€¦ · Probing Challenges with Cu Pillar Phill Mai, ... Composite (multi-layer) structure ... • MT probes have high CCC and MAC even

Guide-plate Wear

16Mai

View: Top of the Guide Plate Oblique Angle View

Initial Guide Plate

Optimized Guide Plate

Wear :4.4~5.5μm(n=5)

Wear :2.1~3.1μm(n=4)

Top

Bottom

Page 17: Probing Challenges with Cu Pillar - SWTest.org€¦ · Probing Challenges with Cu Pillar Phill Mai, ... Composite (multi-layer) structure ... • MT probes have high CCC and MAC even

MT-to-Cu Pillar Probe Mark (multiple contacts)

17Mai

Percentage of flat-to-initial diameter 34% 36% 38% 49% 54% 60% 27% 28% 30%

Contact Mark Diameter (μm) 12 13 13 17 19 21 10 10 10

Contact Mark Depression (μm) 0.8 0.9 1.5 2.0 2.5 3.4 0.6 0.6 0.8

Temp.TD counts 1st 2nd 5th 1st 2nd 5th 1st 2nd 5th

ContactMark

30℃ 125℃ -40℃

RT -40℃125℃

Page 18: Probing Challenges with Cu Pillar - SWTest.org€¦ · Probing Challenges with Cu Pillar Phill Mai, ... Composite (multi-layer) structure ... • MT probes have high CCC and MAC even

Flat-to-Cu pillar CRES Stability

18Mai

*CRes includes ~2 ohms of resistance due to PCB, Space transformer, Interposer, and probe body.

・ Current: 50 mA・ OD: 70μm (from last pin)・ Cleaning Sheet: WA6000 lapping paper・ Cleaning Sheet OD: 70μm (from last pin)

RT (30℃) HT (125℃) LT (-35℃)

CL3TD200TD

Page 19: Probing Challenges with Cu Pillar - SWTest.org€¦ · Probing Challenges with Cu Pillar Phill Mai, ... Composite (multi-layer) structure ... • MT probes have high CCC and MAC even

Current-Carrying Capacity (CCC)

19Mai

Page 20: Probing Challenges with Cu Pillar - SWTest.org€¦ · Probing Challenges with Cu Pillar Phill Mai, ... Composite (multi-layer) structure ... • MT probes have high CCC and MAC even

Maximum Allowable Current (MAC)

20Mai

MAC : ~650mA

・ MT probe for 80 um pitch・ Contact OD:MT 70μm / VS 100μm・ Pulse:10Pulses @ 1 min-on/1 sec- off・ Current: 600, 650, 700, 750mA・ Number of Pins: 3 pins for MT and VS

Page 21: Probing Challenges with Cu Pillar - SWTest.org€¦ · Probing Challenges with Cu Pillar Phill Mai, ... Composite (multi-layer) structure ... • MT probes have high CCC and MAC even

Bandwidth

21Mai

G S_P S_N G

■ Sparameter Model

MT80 - Differential S11 MT80 - Differential S21

-1dB at 20 GHzPitch:80μmLength:7.23mm

< -20dB up to 10GHz

Page 22: Probing Challenges with Cu Pillar - SWTest.org€¦ · Probing Challenges with Cu Pillar Phill Mai, ... Composite (multi-layer) structure ... • MT probes have high CCC and MAC even

Summary• Probing Cu pillars with minimal bump damage and stable CRES is

challenging.• Crown tips can be used, but tip cleaning is difficult and requires

offline laser cleaning. • Flat-tip MT probes are effective for probing 35 µm dia. Cu pillars if

low-friction guide plates and low probe forces are used.• MT probes have high CCC and MAC even with small probe cross-

sections.

22Mai

Page 23: Probing Challenges with Cu Pillar - SWTest.org€¦ · Probing Challenges with Cu Pillar Phill Mai, ... Composite (multi-layer) structure ... • MT probes have high CCC and MAC even

Future Work

23Mai

• Develop 40um pitch MT probe.• Increase CCC of 60-um-pitch probe to at least 500 mA.• Develop pointed tips for Al pad contact.• Optimize overdrive vs. temperature to minimize bump damage• Increase max. temperature to 175 °C.

Wafer side

ST side

Page 24: Probing Challenges with Cu Pillar - SWTest.org€¦ · Probing Challenges with Cu Pillar Phill Mai, ... Composite (multi-layer) structure ... • MT probes have high CCC and MAC even

Acknowledgements• Atsushi Mine, JEM Japan• ITS

24Mai