CH B- B+ 2.) Use the buon on the Pro Dim 5 Remote to choose the zone you wish to pair. Choose from 5 zones indicated by the small green light. 1.) Disconnect 110 or 220VAC power and wire your Triac Receiver to a 110 or 220VAC triac dimmable light and power source, as seen in the diagram above. CH 3.) Apply 110 or 220VAC power to your Triac Receiver. Immediately aſter press and hold the buon for at least five seconds. If done correctly your triac dimmable light will flash twice and you can begin to control your lights from the remote control. B+ Triac Receiver AC IN AC OUT N L N L GND Input Voltage: 110VAC or 220VAC Output Voltage: 110VAC or 220VAC Max Load: 250W@110V, 500W@220V RoHS WARNING USE ONLY SOLID WIRE FOR AC CONNECTIONS Input Voltage: 110VAC or 220VAC Triac Dimmable Light Max Load: 250W@110V, 500W@220V Pro Dim 5 Triac Receiver Pairing Instrucon