Randall J. Stocks, AIA AR Registration No. 2100 I hereby certify that these plans and specifications have been prepared by me, or under my supervision. I further certify that to the best of my knowledge, these plans and specifications are as required by law and in compliance with the ARKANSAS FIRE PREVENTION CODE for the state of Arkansas. 401 W. CAPITOL, SUITE 402 LITTLE ROCK, AR 501-370-9207 501-370-9208 (FAX) 72201 ISSUE DATE CONTENTS SHEET NUMBER PROJECT NUMBER REVISIONS CONSULTANTS: 7/31/2020 2:17:31 PM PRINCE CENTER ROOF REPLACEMENT T1 TITLE SHEET PRINCE CENTER ROOF REPLACEMENT UNIVERSITY OF CENTRAL ARKANSAS 1505Z 201 DONAGHEY AVE, CONWAY, AR UNIVERSITY OF CENTRAL ARKANSAS CONSTRUCTION DOCUMENTS EXISTING ROOF "A" EXISTING ROOF "B" EXISTING ROOF "C" SHEET INDEX GENERAL T1 TITLE SHEET T2 GENERAL INFORMATION T3 EXISTING ROOF PLAN & CORE INFORMATION T4 EXISTING SITE PLAN DEMOLITION A1.1 DEMOLITION ROOF PLAN A1.2 ROOF EDGE DETAIL - DEMOLITION A1.3 ROOF TRANSITION DETAILS - DEMOLITION A1.4 ROOF DETAILS - DEMOLITION A1.5 PARTIAL EXTERIOR ELEVATIONS ARCHITECTURAL A2.1 RENOVATION ROOF PLAN A2.2 ROOF EDGE DETAIL - RENOVATION A2.3 ROOF TRANSITION DETAILS - RENOVATION A2.4 ROOF DETAILS - RENOVATION A2.5 EXTERIOR ELEVATIONS A2.6 EXTERIOR ELEVATIONS A2.7 MISCELLANEOUS DETAILS No. Description Date NOTE TO BIDDERS: PRINCE CENTER WILL REMAIN OPERATIONAL AND OCCUPIED DURING CONSTRUCTION. ALL SHUT DOWNS REQUIRED DUE TO WORK ON EXISTING PRINCE CENTER UTILITIES AND ROOF TOP EQUIPMENT REQUIRE A 72 HOUR NOTICE TO THE OWNER AND MUST BE COORDINATED WITH THE DAILY OPERATIONS OF THE BUILDING. July 31, 2020 07/31/2020 July 31, 2020
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Randall J. Stocks, AIA AR Registration No. 2100
I hereby certify that these plans and specifications have been prepared by me, or under my supervision. I further certify that to the best of my knowledge, these plans and specifications are as required by law and in compliance with the ARKANSAS FIRE PREVENTION CODE for the state of Arkansas.
401 W. CAPITOL, SUITE 402
LITTLE ROCK, AR
501-370-9207 501-370-9208 (FAX)
72201
ISSUE DATE
CONTENTS
SHEET NUMBER
PROJECT NUMBER
REVISIONS
CONSULTANTS:
7/3
1/2
02
0 2
:17:3
1 P
M
PRINCE CENTER ROOF REPLACEMENT
T1
TITLE SHEET
PR
INC
E C
EN
TE
R R
OO
F R
EP
LA
CE
ME
NT
UN
IVE
RS
ITY
OF
CE
NT
RA
L A
RK
AN
SA
S
1505Z
201
DO
NA
GH
EY
AV
E,
CO
NW
AY
, A
R
UNIVERSITY OF CENTRAL ARKANSAS
CONSTRUCTION DOCUMENTS
EXISTING ROOF "A" EXISTING ROOF "B" EXISTING ROOF "C"
SHEET INDEXGENERAL
T1 TITLE SHEET
T2 GENERAL INFORMATION
T3 EXISTING ROOF PLAN & CORE INFORMATION
T4 EXISTING SITE PLAN
DEMOLITION
A1.1 DEMOLITION ROOF PLAN
A1.2 ROOF EDGE DETAIL - DEMOLITION
A1.3 ROOF TRANSITION DETAILS - DEMOLITION
A1.4 ROOF DETAILS - DEMOLITION
A1.5 PARTIAL EXTERIOR ELEVATIONS
ARCHITECTURAL
A2.1 RENOVATION ROOF PLAN
A2.2 ROOF EDGE DETAIL - RENOVATION
A2.3 ROOF TRANSITION DETAILS - RENOVATION
A2.4 ROOF DETAILS - RENOVATION
A2.5 EXTERIOR ELEVATIONS
A2.6 EXTERIOR ELEVATIONS
A2.7 MISCELLANEOUS DETAILS
No. Description Date
NOTE TO BIDDERS:PRINCE CENTER WILL REMAIN OPERATIONAL AND OCCUPIED DURING CONSTRUCTION. ALL SHUT DOWNS REQUIRED DUE TO WORK ON EXISTING PRINCE CENTER UTILITIES AND ROOF TOP EQUIPMENT REQUIRE A 72 HOUR NOTICE TO THE OWNER AND MUST BE COORDINATED WITH THE DAILY OPERATIONS OF THE BUILDING.
T&B TOP AND BOTTOMTREAT TREATEDTEL TELEPHONET.O.C. TOP OF CURB, TOP OF
CONCRETET.O.B. TOP OF BEAMT.P. TOILET PARTITIONT.B. TACK BOARDT.B.R. TO BE REMOVEDTHK THICKT.J. TOOLED JOINTT TREADTHRESH THRESHOLDT.O.W. TOP OF WALLTOJ TOP OF JOINTTYP TYPICALT&G TONGUE & GROOVETHRU THROUGHTPD TEMPREREDTLT TOILET
EQUIPMENT BY OWNER(INSTALLATION BY G.C. WHERE REQ'D.)
GENERAL AREA OF REVISION
NEW CONSTRUCTION KEYNOTE SYMBOL
1
REVISION NUMBER
N
1 DEMOLITION KEYNOTE SYMBOL
EXISTING ELEMENTS TO REMAIN
EXISTING ELEMENTS TO BE REMOVED
NEW ELEMENTS
1
Ref
A101
1
CONCRETE
C.M.U.
FACE BRICK
STEEL
BATT INSULATION
RIGID INSULATION
WOOD - FINISHED
WOOD - ROUGH
PLYWOOD
SOIL
GYPSUM BOARD / SHEATHING
GRAVEL
EXISTING WALLS TO REMAIN
EXISTING WALLS TO BE REMOVED
NEW WALLS
STONE VENEER
A. OCCUPANCY CLASSIFICATION
B. TYPE OF CONSTRUCTION
• 2012 Arkansas Fire Prevention Code(based on the 2012 International Fire Code w/ Arkansas Amendments)Americans with Disabilities Act (ADA)(based on the 2010 Americans with Disabilities Act)
• Arkansas State Plumbing Code 2006 (9th Addition)
• Arkansas Mechanical Code 2010
• National Electric Code 2010
• Arkansas Energy Code Rules & Regulations for Energy Efficiency Standards, 2009 ICC W/ Arkansas Amendments
• ASHRAE 90.1-2007
APPLICABLE CODES
C. ALLOWABLE HEIGHT AND BUILDING AREA PER FLOOR
D. FLOOR AREAS AND OCCUPANT LOADS (EXISTING & PROPOSED)
E. SEPARATION DISTANCES FOR EACH EXTERIOR WALL
F. EXIT ACCESS CORRIDOR & STAIR SHAFT ENCLOSURE PROTECTION REQUIREMENTS
G. ALL RATED CONSTRUCTION ASSEMBLIES
EXISTING BUILDING DATA
H. ALL FIRESTOP ASSEMBLIES
I. STATEMENT OF SPECIAL INSPECTIONS
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
SYMBOLS LEGEND ABBREVIATIONS LEGEND
CODE INFORMATION
1. DIMENSIONS ON DRAWINGS TERMINATE AT FACE OF MASONRY OR CENTERLINE OF OBJECT, UNLESS OTHERWISE NOTED. DO NOT SCALE DRAWINGS - WRITTEN DIMENSIONS TAKE PRECEDENCE OVER GRAPHIC REPRESENTATIONS. DETAIL DIMENSIONS TAKE PRECEDANCE OVER PLANS AND ELEVATIONS.
2. ALL DIMENSION REVISIONS, MODIFICATIONS AND DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR REVIEW AND CLARIFICATION PRIOR TO THE INSTALLATION OF THE WORK.
3. THE CONTRACTOR SHALL VISIT THE SITE TO VERIFY EXISTING DIMENSIONS AND CONDITIONS PRIOR TO STARTING THE WORK. BEGINNING THE WORK CONSTITUTES ACCEPTANCE OF THE EXISTING CONDITIONS.
4. ANY INTERRUPTION IN POWER OR UTILITY SERVICE TO THE BUILDING MUST BE COORDINATED WITH THE OWNER, AT A MINIMUM, ONE WEEK BEFORE THE SHUT DOWN IS REQUIRED.
5. CONTRACTOR AND ALL SUB-CONTRACTORS SHALL ADHERE TO THE OWNER'S SMOKING POLICY DURING CONTRUCTION.
6. CONTRACTOR TO TAKE ALL NECESSARY PRECAUTIONS TO PROTECT THE FACILITY, PERSONNEL, EXISTING EQUIPMENT, AND EXISTING FINISHES.
7. PROVIDE EMERGENCY FIRE EXTINGUISHERS THAT ARE READILY AVAILABLE AND PROPERLY MAINTAINED AT THE JOB SITE - AS PER LOCAL FIRE PROTECTION REGULATIONS.
8. WORK AREA SHALL BE CLEANED AT THE END OF EACH WORK DAY - AND MORE OFTEN WHEN NECESSARY. PROPERLY DISPOSE OF CONSTRUCTION WASTE. STOCKPILING DEBRIS ON SITE IS NOT PERMITTED.
9. CONTRACTOR SHALL TAKE THE NECESSARY STEPS TO PREVENT THE INFILTRATION OF DUST, DIRT, AND ODORS INTO ANY ADJACENT OCCUPIED AREAS.
EXISTING THROUGH WALL SCUPPER - DOWN SPOUT EXTENDS TO ROOF BELOW
EXISTING SCUPPER WITH DRAIN COVER
EXISTING SCUPPER WITH DRAIN COVER
EXISTING SCUPPER WITH DRAIN COVER
SLO
PE
DO
WN
SLO
PE
DO
WN
EXISTING FIXED VERTICAL LADDER
EXISTING GUTTER AND DOWN SPOUT
EXISTING GUTTER AND DOWN SPOUT
EXISTING STEEL TUBE COLUMN EXISTING COMPRESSOR -
REFRIGERANT SUPPLY AND RETURN LINES SUPPORTED AT ROOF WITH STEEL ANGLES
SLO
PE
DO
WN
SLO
PE
DO
WN
EXISTING ONE WAY VENT (O.W.V.) - TYP.
EXISTING EQUIPMENT CURB - TYP.
EXISTING FUME HOOD EXHAUST FAN
EXISTING FLEXIBLE FLASHING OVER STONE COPING
EXISTING PRE-CAST CONCRETE COPING - TYP.
EXISTING THROUGH WALL SCUPPER, COLLECTOR, AND DOWN SPOUT - TYP.
EXISTING EQUIPMENT EXHAUST PIPE @ EXTERIOR WALL
1. FIELD VERIFY ALL DIMENSIONS.2. ROOF CORE INFORMATION PROVIDED BY ROOFING
CONSULTANT. CORE INFORMATION TO BE VERIFIED IN FIELD BY GENERAL CONTRACTOR. NOTIFY THE ARCHITECT IF THERE ARE ANY DISCREPENCIES.
3. O.W.V. = ONE WAY VENT
EXISTING THROUGH WALL SCUPPER, COLLECTOR, AND DOWN SPOUT - TYP.
O.W.V.
O.W.V.
V.T.R. O.W.V.
O.W.V.
V.T.R.
EXISTING ROOF MOUNTED EXHAUST
O.W.V. O.W.V.
O.W.V.
O.W.V.
O.W.V.
O.W.V.
EXISTING PENTHOUSE EXHAUST VENT
EXISTING PENTHOUSE EXHAUST VENT
V.T.R.
O.W.V.
O.W.V.
V.T.R. STACK
ROOF MOUNTED EXHAUST
ROOF MOUNTED EXHAUST
ROOF MOUNTED EXHAUST
V.T.R.
V.T.R.ROOF MOUNTED
EXHAUST
O.W.V.
O.W.V.
O.W.V.
O.W.V.
ROOF MOUNTED EXHAUST
GAS LINE ENTRANCE INTO BUILDING
V.T.R.
ROOF MOUNTED EXHAUST
EXISTING GAS LINE
V.T.R.
THROUGH WALL SCUPPER, COLLECTOR, AND DOWN SPOUT
THROUGH WALL SCUPPER, COLLECTOR, AND DOWN SPOUT
THROUGH WALL SCUPPER, COLLECTOR, AND DOWN SPOUT
THROUGH WALL SCUPPER, COLLECTOR, AND DOWN SPOUT
EXISTING THROUGH WALL SCUPPER, COLLECTOR, AND DOWN SPOUT - TYP.
EXISTING THROUGH WALL SCUPPER, COLLECTOR, AND DOWN SPOUT - TYP.
THROUGH WALL SCUPPER,
COLLECTOR, AND DOWN SPOUT
THROUGH WALL SCUPPER,
COLLECTOR, AND DOWN SPOUT
THROUGH WALL SCUPPER,
COLLECTOR, AND DOWN SPOUT
THROUGH WALL SCUPPER,
COLLECTOR, AND DOWN SPOUT
1' -
4"
4"
TYPICAL PILASTER
TYPICAL PILASTER
TYPICAL PILASTER
TYPICAL PILASTER
TYPICAL PILASTER
TYPICAL PILASTER
V.T.R.
GENERAL NOTES
401 W. CAPITOL, SUITE 402
LITTLE ROCK, AR
501-370-9207 501-370-9208 (FAX)
72201
CONSULTANTS:
ISSUE DATE
CONTENTS
SHEET NUMBER
PROJECT NUMBER
REVISIONS
7/3
1/2
02
0 2
:20:4
5 P
M
T3
EXISTING ROOFPLAN & COREINFORMATION
1505Z
PR
INC
E C
EN
TE
R R
OO
F R
EP
LA
CE
ME
NT
UN
IVE
RS
ITY
OF
CE
NT
RA
L A
RK
AN
SA
S
201
DO
NA
GH
EY
AV
E,
CO
NW
AY
, A
R
N
1/8" = 1'-0"1
EXISTING ROOF PLAN
07/31/2020
July 31, 2020
MARION ROSS AVENUE
EM
MA
RA
SO
R D
RIV
E
BR
UC
E S
TR
EE
T
BEAR HALL AND ATHLETIC ADIMINISTRATION
LANEY - MANION HALL
PHYSICAL THERAPY CENTER
ME
CH
AN
ICA
L Y
AR
D
PRINCE CENTER
SERVICE DRIVE
PROJECT STAGING
AREA
PROTECT PEDESTRIAN TRAFFIC AND SIDEWALKS AROUND ENTIRE BUILDING DURING CONSTRUCTION.
PROVIDE SAFETY FENCING AROUND AREAS OF SIDWALK WHERE EQUIPMENT WILL BE USED.
COORDINATE AREAS WITH OWNER THAT REQUIRE TEMPORARY ACCESS RESTRICTIONS
DOCK
PROTECT ALL TREES AND PLANTINGS IN THE PROJECT AREA. PROVIDE PROTECTIVE
FENCING OR COVERING AS REQUIRED.
TYPICAL SODDED AREA AROUND BUILDING - REPAIR ANY SODDED AREAS THAT ARE DAMAGED DURING CONSTRUCTION. MATCH TYPE AND SPECIES OF ADJACENT GRASS WHEN REPAIRING SOD.SEE DETAIL:
A2.7
1REF
/3 A2.7
REPAIR ANY SIDEWALK SECTION THAT IS DAMAGED DURING CONSTRUCTION -SIMILAR TO DETAIL: /2 A2.7
TEMPORARY CONSTRUCTION FENCE -
COORDINATE FINAL FENCE LAYOUT WITH OWNER
BEFORE INSTALLATION
401 W. CAPITOL, SUITE 402
LITTLE ROCK, AR
501-370-9207 501-370-9208 (FAX)
72201
CONSULTANTS:
ISSUE DATE
CONTENTS
SHEET NUMBER
PROJECT NUMBER
REVISIONS
7/3
1/2
02
0 3
:47:2
7 P
M
T4
EXISTING SITE PLAN
1505Z
PR
INC
E C
EN
TE
R R
OO
F R
EP
LA
CE
ME
NT
UN
IVE
RS
ITY
OF
CE
NT
RA
L A
RK
AN
SA
S
201
DO
NA
GH
EY
AV
E,
CO
NW
AY
, A
R
N
1" = 20'-0"1
EXISTING SITE PLAN
July 31, 2020
07/31/2020
1
A1.2
_______
4
A1.2
_______
3
A1.2
_______
1
A1.3
_______
6
A1.2
_______
2
A1.2
_______
2
A1.3
_______
5
A1.3
_______
4
A1.3
_______
3
A1.3
_______
5
A1.2
_______
BELOW
BELOW
BELOW
BELOW
6
A1.3
_______
ROOF 'A'ROOF 'C'
ROOF 'B'
ROOF 'E'
ROOF 'G'
ROOF 'F'
ROOF 'D'
5
A1.2
Sim
_______
3
A1.2
Sim
_______
5
A1.2
Sim
_______
5
A1.3
Sim
_______
3
A1.2
Sim
_______ 5
5
2
A1.2
Sim
_______
1
A1.2
Sim
_______
1
A1.2
Sim
_______
2
A1.2
Sim
_______
2
A1.2
Sim
_______
2
A1.2
Sim
_______
3
A1.4
_______
1
A1.4
_______
2
A1.4
_______
CAP GAS LINE AT BUILDING ENTRANCE
6
A1.3
Sim
_______
4
A1.4
_______
5
A1.4
_______
1
1
1
1
1
1
1
1
1a
2 2
2 2
2 2
22 2 2
2 2 2
2 2 2
2 2 2
2 2 2
2 2 2
3
3
17
REMOVE LIQUID FLASHING AROUND EXISTING CURB -EXHAUST FAN AND CURB TO REMAIN - PREP CURB TO RECEIVE NEW PRIMER
3
17
17
3
3
3
3
4
4
4
14
14
4
4
4
4
4 4 4 4
4 4 4
4
4
4
4
4
5
6
6
6
7
8
8
8
8
8
8
9 9 9
10
11
11
APPROX. COLUMN LINE @ GYM
APPROX. COLUMN LINE @ GYM
A1.5 1
A1.5 2
A1.5
3
A1.5
4A2.51
A2.5
2
A2.6 1
A2.6
2
BUILDING CENTER LINE
1
1
1
1
STRUCTURAL STEEL FRAMING TO REMAIN
OUTDOOR CONDENSER UNIT TO REMAIN - DISCONNECT EXISTING REFRIGERANT LINES
8
17
8
SLO
PE
DO
WN
SLO
PE
DO
WN
VE
RIF
Y R
OO
F I
N T
HE
FIE
LD
EX
IST
ING
LA
NE
Y H
AL
L R
OO
F T
O R
EM
AIN
15
16 16
4
REMOVE EXISTING STRAINER AND REINSTALL AFTER NEW ROOFING & FLASHING IS INSTALLED
6
A2.4
_______
4' - 0" 4' - 0"
6
A1.4
_______
1. DASHED LINES INDICATE COMPONENTS TO BE REMOVED UNLESS NOTED OTHERWISE
2. PROTECT ALL EXISTING FINISHES AND BUILDING ELEMENTS TO REMAIN.
3. PROTECT EXISTING BUILDING INFRASTRUCTURE TO REMAIN, SUCH AS BUT NOT LIMITED TO, TELECOMMUNICATIONS CABLING AND EQUIPMENT, CONDUIT, PIPING, INSULATION, ELECTRICAL DEVICES AND DATA JACKS FROM DAMAGE, DEBRIS, DUST AND LOSS OF USE DURING ALL PHASES OF CONSTRUCTION. COMPONENTS THAT ARE DAMAGED OR BECOME DIRTY DURING THE CONSTRUCTION PHASE ARE TO BE REPLACED OR CLEANED TO ORIGINAL CONDITION AT NO ADDITIONAL COST TO THE OWNER.
4. PROTECT ALL EXPANSION JOINT COVERS DURING DEMOLITION.
1. REMOVE EXISTING ROOF INSULATION, ROOF PLIES, AND TORCH APP. MEMBRANE DOWN TO EXISTING WOOD DECK. REPAIR ANY DECKING BEFORE INSTALLATION OF NEW ROOF INSULATION AND ROOF MEMBRANE (UNIT PRICE ALLOWANCE - SEE SPECS).
REMOVE EXISTING ROOF INSULATION, ROOF PLIES, AND TORCH APP. MEMBRANE DOWN TO EXISTING METAL DECK. REPAIR ANY DECKING BEFORE INSTALLATION OF NEW ROOF INSULATION AND ROOF MEMBRANE (UNIT PRICE ALLOWANCE - SEE SPECS).
2. REMOVE EXISTING ONE WAY VENT.
3. REMOVE EXISTING EQUIPMENT, FLASHING, AND CURB. PROTECT AND STORE EXISTING EQUIPMENT FOR RE-INSTALLATION ON NEW ROOF. PROTECT OPENING FOR INSTALLATION WHERE NEW CURB IS REQUIRED TO MAINTAIN MIN. CLEARANCE ABOVE ROOF MEMBRANE.EQUIPMENT WORK REQUIRING A UTILITY SHUT DOWN MUST BE COORDINATED WITH THE OWNER WHO SHALL BE NOTIFIED WITHIN A MINIMUM OF 72 HOURS PRIOR TO THE WORK OF THE SHUT DOWN.
4. REMOVE EXISTING SCUPPER FLASHING.
5. REMOVE EXISTING FLEXIBLE FLASHING AT PRE-CAST CONCRETE COPING.
6. REMOVE GAS LINE AND ASSOCIATED ROOF SLEEPERS. PROVIDE TEMPORARY CAP AT GAS LINE BELOW ROOF 'E' DURING CONSTRUCTION.
7. PROTECT LOOSE DATA OUTLET DURING CONSTRUCTION. COORDINATE W/ OWNER.
8. EXISTING ROOF VENT TO REMAIN. SEE DETAIL 3 ON SHEET A1.4.
9. EXISTING VERTICAL LADDER TO REMAIN.
10. EXISTING COMPRESSOR UNITS AND STEEL FRAME TO REMAIN - REMOVE EXISTING REFRIGERANT LINES, SUCTION LINES, AND LIQUID LINES (WITH ANGLE SUPPORTS) FOR NEW ROOF INSTALLATION.
11. REMOVE EXISTING GUTTER AND DOWN SPOUT.
12. REMOVE EXISTING CAULK AND RE-CAULK AROUND EXISTING OPENING THIS AREA. (SEE SHEET A1.5)
13. REMOVE EXISTING MASONRY GROUT THIS AREA - RE-INSTALL NEW MASONRY GROUT AS SPECIFIED, MATCH EXISTING GROUT COLOR. (SEE SHEET A1.5)
14. REMOVE EXISTING SCUPPER FLASHING AND STRAINER. CAP DOWNSPOUT BELOW ROOF LINE.
15. REMOVE EXISTING DOWNSPOUT AND CONDUCTOR HEAD. REMOVE DOWNSPOUT STRAPS FROM EXTERIOR WALL. CAP DOWNSPOUT AT TOP OF EXISTING SIDEWALK.
16. REMOVE EXISTING MASONRY FOR NEW THROUGH WALL SCUPPER.
17. EXISTING CURB TO REMAIN. EQUIPMENT SHALL REMAIN IN OPERATION DURING CONSTRUCTION. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AND THE OWNER IF ANY PART OF THE CURB IS DAMAGED AND REQUIRES REPLACEMENT. LAB EQUIPMENT EXHAUST SHALL BE DISCONNECTED AND RECONNECTED FOR ROOF MEMBRANE FLASHING AND CURB CAP FLASHING IN ONE WORKING DAY. THE DISCONNECTION SHALL BE COORDINATED WITH THE OWNER AT A MIN. OF 72 HOURS PRIOR TO THE WORK.
1a.
NOTE: DETAILS ARE BASED ON FIELD OBSERVATIONS AND INFORMATION FROM ORIGINAL DRAWINGS. FIELD VERIFY ACTUAL CONDITION AT TIME OF ROOF REMOVAL AND NOTIFY THE ARCHITECT IF THERE ARE ANY DISCREPENCIES.
1. REFER TO SPECIFICATIONS SECTION 07 01 50.19 FOR ROOFING REMOVAL PROCEDURES.
2. REMOVE ONLY AS MUCH ROOFING IN ONE DAY AS CAN BE MADE WATERTIGHT IN THE SAME DAY (SEE TEMPORARY ROOFING MEMBRANE REQUIREMENT FOR ROOF SECTIONS: A, B, & C.)
3. NOTIFY THE ARCHITECT OF ANY DETERIORATED OR DAMAGED WOOD BLOCKING, NAILERS, OR CURBS THAT ARE NOT INDICATED IN THE DRAWINGS TO BE REMOVED. REMOVAL AND REPLACEMENT WILL BE ADDED TO THE CONTRACT VIA CHANGE ORDER.
4. NOTIFY THE ARCHITECT OF ANY DETERIORATED OR DAMAGED ROOF DECKING AND REPLACE AS DIRECTED - SEE UNIT PRICING AND UNIT-PRICE ALLOWANCE UNDER SPEC SECTION 01 22 00.
5. NOTIFY THE ARCHITECT OF ADDITIONAL MASONRY TUCK POINTING THAT IS REQUIRED. REMOVE AND REPLACE ADDITIONAL MORTAR JOINTS ONLY AS DIRECTED. SEE UNIT PRICING AND UNIT PRICE ALLOWANCE UNDER SPEC SECTION 01 22 00.
GENERAL NOTES:
401 W. CAPITOL, SUITE 402
LITTLE ROCK, AR
501-370-9207 501-370-9208 (FAX)
72201
CONSULTANTS:
ISSUE DATE
CONTENTS
SHEET NUMBER
PROJECT NUMBER
REVISIONS
7/3
1/2
02
0 2
:25:4
0 P
M
A1.1
DEMOLITION ROOFPLAN
1505Z
PR
INC
E C
EN
TE
R R
OO
F R
EP
LA
CE
ME
NT
UN
IVE
RS
ITY
OF
CE
NT
RA
L A
RK
AN
SA
S
201
DO
NA
GH
EY
AV
E,
CO
NW
AY
, A
R
N
1/8" = 1'-0"1
DEMOLITION ROOF PLAN
DEMOLITION NOTES
KEYNOTES - DEMO
07/31/2020
July 31, 2020
EXISTING STONE COPING TO REMAIN
EXISTING MASONRY WALL TO REMAIN
EXISTING ROOF DECK TO REMAIN
REMOVE EXISTING INSULATION BOARDS AND ROOFING MEMBRANE -HEIGHT VARIES ALONG PERIMETER
REMOVE EXISTING PERIMETER CANT
REMOVE EXISTING ROOFING BOARD
REMOVE EXISTING TERMINATION STRIP
EXISTING STONE REMAIN
EXISTING STONE COPING TO REMAIN
EXISTING MASONRY WALL TO REMAIN
EXISTING ROOF DECK TO REMAIN
REMOVE EXISTING INSULATION BOARDS AND
ROOFING MEMBRANE
REMOVE EXISTING PERIMETER CANT
REMOVE EXISTING ROOFING BOARD
REMOVE EXISTING TERMINATION STRIP
EXISTING STONE COPING TO REMAIN
EXISTING MASONRY WALL TO REMAIN
EXISTING ROOF DECK TO REMAIN
REMOVE EXISTING INSULATION BOARDS AND ROOFING MEMBRANE
REMOVE EXISTING PERIMETER CANT
REMOVE EXISTING ROOFING BOARD
REMOVE EXISTING TERMINATION STRIP
EXISTING STONE TO REMAIN
EXISTING STONE COPING TO REMAIN
EXISTING MASONRY WALL TO REMAIN
EXISTING ROOF DECK TO REMAIN
REMOVE EXISTING INSULATION BOARDS AND
ROOFING MEMBRANE
REMOVE EXISTING PERIMETER CANT
REMOVE EXISTING ROOFING BOARD
REMOVE EXISTING TERMINATION STRIP
EXISTING STONE COPING TO REMAIN
EXISTING MASONRY WALL TO REMAIN
EXISTING ROOF DECK TO REMAIN
REMOVE EXISTING INSULATION BOARDS AND
ROOFING MEMBRANE
REMOVE EXISTING PERIMETER CANT
REMOVE EXISTING ROOFING BOARD
REMOVE EXISTING TERMINATION STRIP
EXISTING STONE TO REMAIN
EXISTING STONE COPING TO REMAIN
EXISTING MASONRY WALL TO REMAIN
EXISTING ROOF DECK TO REMAIN
REMOVE EXISTING INSULATION BOARDS AND
ROOFING MEMBRANE
REMOVE EXISTING PERIMETER CANT
REMOVE EXISTING ROOFING BOARD
REMOVE EXISTING TERMINATION STRIP
401 W. CAPITOL, SUITE 402
LITTLE ROCK, AR
501-370-9207 501-370-9208 (FAX)
72201
CONSULTANTS:
ISSUE DATE
CONTENTS
SHEET NUMBER
PROJECT NUMBER
REVISIONS
7/3
1/2
02
0 2
:26:1
6 P
M
A1.2
ROOF EDGE DETAIL -DEMOLITION
1505Z
PR
INC
E C
EN
TE
R R
OO
F R
EP
LA
CE
ME
NT
UN
IVE
RS
ITY
OF
CE
NT
RA
L A
RK
AN
SA
S
201
DO
NA
GH
EY
AV
E,
CO
NW
AY
, A
R
3" = 1'-0"2
ROOF B EDGE DETAIL - DEMOLITION
3" = 1'-0"6
ROOF F EDGE DETAIL - DEMOLITION
3" = 1'-0"1
ROOF A EDGE DETAIL - DEMOLITION
3" = 1'-0"4
ROOF D EDGE DETAIL - DEMOLITION3" = 1'-0"
5ROOF E EDGE DETAIL - DEMOLITION
3" = 1'-0"3
ROOF C EDGE DETAIL - DEMOLITION
07/31/2020
July 31, 2020
EXISTING ROOF DECK TO REMAIN
EXISTING MASONRY WALL TO REMAIN
REMOVE EXISTING INSULATION BOARDS
AND ROOFING MEMBRANE
EXISTING GAS PIPING TO REMAIN - REMOVE EXISTING
SUPPORTS AND PROVIDE TEMPORARY SUPPORTS DURING CONSTRUCTION
REMOVE EXISTING GUTTER AND DOWNSPOUT REMOVE EXISTING
INSULATION BOARDS AND ROOFING MEMBRANE
REMOVE PERIMETER BLOCKING
REMOVE METAL DRIP EDGE
REMOVE EXISTING TERMINATION BAR
REMOVE EXISTING ROOFING
MEMBRANE
REMOVE EXISTING TERMINATION BAR
REMOVE EXISTING ROOFING MEMBRANE
REMOVE EXISTING INSULATION BOARDS AND
ROOFING MEMBRANE
EXISTING ROOF DECK TO REMAIN
EXISTING MASONRY WALL TO REMAIN
REMOVE EXISTING CANT STRIP
EXISTING GAS PIPING TO BE REMOVED - CAP GAS LINE TO RE-ROUTE DURING RENOVATION
REMOVE EXISTING TERMINATION BAR
REMOVE EXISTING ROOFING MEMBRANE
REMOVE EXISTING INSULATION BOARDS AND ROOFING MEMBRANE
EXISTING ROOF DECK TO REMAIN
EXISTING MASONRY WALL TO REMAIN
REMOVE EXISTING SLEEPER
REMOVE EXISTING TERMINATION BAR
REMOVE EXISTING ROOFING MEMBRANE
REMOVE EXISTING INSULATION BOARDS AND ROOFING MEMBRANE
EXISTING ROOF DECK TO REMAIN
EXISTING MASONRY WALL TO REMAIN
REMOVE EXISTING TERMINATION BAR
REMOVE EXISTING ROOFING MEMBRANE
REMOVE EXISTING INSULATION BOARDS AND
ROOFING MEMBRANE
EXISTING ROOF DECK TO REMAIN
EXISTING MASONRY WALL TO REMAIN
REMOVE EXISTING CANT STRIP
EXISTING STONE COPING TO REMAIN
EXISTING MASONRY WALL TO REMAIN
EXISTING ROOF DECK TO REMAIN
REMOVE EXISTING INSULATION BOARDS AND ROOFING MEMBRANE
REMOVE EXISTING PERIMETER CANT
REMOVE EXISTING ROOFING BOARD
REMOVE EXISTING TERMINATION STRIP
EXISTING EXTERIOR INSULATING FINISH SYSTEM TO REMAIN
LANEY-MANION HALL ROOF 'C'
401 W. CAPITOL, SUITE 402
LITTLE ROCK, AR
501-370-9207 501-370-9208 (FAX)
72201
CONSULTANTS:
ISSUE DATE
CONTENTS
SHEET NUMBER
PROJECT NUMBER
REVISIONS
7/3
1/2
02
0 2
:26:4
6 P
M
A1.3
ROOF TRANSITIONDETAILS -DEMOLITION
1505Z
PR
INC
E C
EN
TE
R R
OO
F R
EP
LA
CE
ME
NT
UN
IVE
RS
ITY
OF
CE
NT
RA
L A
RK
AN
SA
S
201
DO
NA
GH
EY
AV
E,
CO
NW
AY
, A
R
3" = 1'-0"5
ROOF "C" TO "D" TRANSITION - DEMOLITION
3" = 1'-0"1
ROOF "A" TO WALL TRANSITION - DEMOLITION3" = 1'-0"
2ROOF "C" TO WALL TRANSITION - DEMOLITION
3" = 1'-0"3
ROOF "G" TO WALL TRANSITION - DEMOLITION
3" = 1'-0"4
ROOF "E" TO WALL TRANSITION - DEMOLITION3" = 1'-0"
6TRANSITION ROOF "C" TO ADDITION - DEMOLITION
07/31/2020
July 31, 2020
REMOVE ALL FLASHING AT SCUPPER OPENING
EXISTING PRECAST CONCRETE COPING TO
REMAIN - REMOVE EXCESS SEALANT FROM
CONCRETE
REMOVE EXISTING TORCH APP. ROOF
MEMBRANE AND ROOF INSULATION TO EXISTING
WOOD DECKING
EXISTING WOOD DECK TO REMAIN
EXISTING EXTERIOR MASONRY WALL TO
REMAIN
EXISTING CONDUCTOR HEAD AND DOWNSPOUT
TO REMAIN
REMOVE ALL FLASHING AT SCUPPER OPENING
EXISTING PRECAST CONCRETE COPING TO
REMAIN - REMOVE EXCESS SEALANT FROM
CONCRETE
EXISTING WOOD DECK TO REMAIN
EXISTING EXTERIOR MASONRY WALL TO
REMAIN
REMOVE EXISTING TERMINATION BAR AND
TORCH APP. MEMBRANE
REMOVE EXISTING TORCH APP. ROOF
MEMBRANE AND ROOF INSULATION TO EXISTING
WOOD DECKING
REMOVE ANY EXISTING COVERBOARD OR
FURRING / BLOCKING
REMOVE LEAD FLASHING AT WASTE VENTS
VE
RIF
Y IN
FIE
LD
EXISTING VENT PIPE TO REMAIN
REMOVE TORCH APP. ROOF MEMBRANE AND ROOFING INSULATION TO EXISTING DECK
EXISTING WOOD DECKING TO REMAIN - PATCH DECK AS REQUIRED
EXISTING DUCT TO REMAIN
EXISTING DECK TO REMAIN
VERIFY IN FIELD
REMOVE CURB FLASHING
REMOVE CURB BLOCKING
REMOVE ROOFING BOARD AND INSULATION
REMOVE TORCH APP. ROOF MEMBRANE AND CANT STRIP
REMOVE EXISTING ROOFTOP EQUIPMENT, PROTECT DURING
CONSTRUCTION, AND REINSTALL IN NEW ROOFING SYSTEM.
THIS DETAIL SHALL BE USED FOR CURB REPLACEMENT BETWEEN DEMOLITION OF THE EXISTING
ROOF AND THE INSTALLATION OF THE FINAL CURB FLASHING.
REMOVE EXISTING ROOF HATCH, PROTECT DURING CONSTRUCTION, AND REINSTALL IN NEW ROOFING
SYSTEM.
REMOVE EXISTING BLOCKING
REMOVE EXISTING ROOF HATCH AND SALVAGE FOR REINSTALLATION
REMOVE EXISTING TORCH APP. ROOF MEMBRANE AND CANT STRIP
VERIFY IN FIELD
EXISTING ROOF DECK TO REMAIN
REMOVE EXISTING ROOFING BOARD AND INSULTATION TEMPORARY ROOFING
MEMBRANE
TEMPORARY TPO MEMBRANE TO EXTEND
18" BEYOND OPENING
TEMPORARY MEMBRANE FASTENER AND CUT
EDGE SEALANT
NEW CURB BLOCKING -SEE DETAIL:
/4 A2.4
OPENING - V.I.F.
CE
NT
ER
LIN
E O
F O
PE
NIN
G
PARTIAL APPLICATION OF BONDING ADHESIVE
401 W. CAPITOL, SUITE 402
LITTLE ROCK, AR
501-370-9207 501-370-9208 (FAX)
72201
CONSULTANTS:
ISSUE DATE
CONTENTS
SHEET NUMBER
PROJECT NUMBER
REVISIONS
7/3
1/2
02
0 2
:27:1
3 P
M
A1.4
ROOF DETAILS -DEMOLITION
1505Z
PR
INC
E C
EN
TE
R R
OO
F R
EP
LA
CE
ME
NT
UN
IVE
RS
ITY
OF
CE
NT
RA
L A
RK
AN
SA
S
201
DO
NA
GH
EY
AV
E,
CO
NW
AY
, A
R
3" = 1'-0"1
SCUPPER DETAIL - OPEN COPING - DEMOLITION3" = 1'-0"
2SCUPPER DETAIL - THROUGH WALL - DEMOLITION
3" = 1'-0"3
TYP. VENT THROUGH ROOF - DEMOLITION
3" = 1'-0"4
TYP. CURB DETAIL - DEMOLITION3" = 1'-0"
5TYP. ROOF HATCH DETAIL - DEMOLITION
3" = 1'-0"6
CURB REPLACEMENT - TEMPORARY FLASHING
07/31/2020
July 31, 2020
13
12
13
13
12 12
13 13ROOF "F"
ROOF "C"
ROOF "D"
ROOF "B"
ACCESS LADDER TO ROOF "B"
10 S.F.
8 S.F.
40 S.F. 34 S.F. 34 S.F.
12
1313
12
ROOF "D"
ROOF "E"
ACCESS LADDER TO ROOF "D"
ROOF "C"
13
20 S.F.36 S.F.
4 S.F.
13
ROOF "B"
ROOF "E"
10 S.F.
13
ROOF "B"
ROOF "F"
4 S.F.
1. REMOVE EXISTING ROOF INSULATION, ROOF PLIES, AND TORCH APP. MEMBRANE DOWN TO EXISTING WOOD DECK. REPAIR ANY DECKING BEFORE INSTALLATION OF NEW ROOF INSULATION AND ROOF MEMBRANE (UNIT PRICE ALLOWANCE - SEE SPECS).
REMOVE EXISTING ROOF INSULATION, ROOF PLIES, AND TORCH APP. MEMBRANE DOWN TO EXISTING METAL DECK. REPAIR ANY DECKING BEFORE INSTALLATION OF NEW ROOF INSULATION AND ROOF MEMBRANE (UNIT PRICE ALLOWANCE - SEE SPECS).
2. REMOVE EXISTING ONE WAY VENT.
3. REMOVE EXISTING EQUIPMENT, FLASHING, AND CURB. PROTECT AND STORE EXISTING EQUIPMENT FOR RE-INSTALLATION ON NEW ROOF. PROTECT OPENING FOR INSTALLATION WHERE NEW CURB IS REQUIRED TO MAINTAIN MIN. CLEARANCE ABOVE ROOF MEMBRANE.EQUIPMENT WORK REQUIRING A UTILITY SHUT DOWN MUST BE COORDINATED WITH THE OWNER WHO SHALL BE NOTIFIED WITHIN A MINIMUM OF 72 HOURS PRIOR TO THE WORK OF THE SHUT DOWN.
4. REMOVE EXISTING SCUPPER FLASHING.
5. REMOVE EXISTING FLEXIBLE FLASHING AT PRE-CAST CONCRETE COPING.
6. REMOVE GAS LINE AND ASSOCIATED ROOF SLEEPERS. PROVIDE TEMPORARY CAP AT GAS LINE BELOW ROOF 'E' DURING CONSTRUCTION.
7. PROTECT LOOSE DATA OUTLET DURING CONSTRUCTION. COORDINATE W/ OWNER.
8. EXISTING ROOF VENT TO REMAIN. SEE DETAIL 3 ON SHEET A1.4.
9. EXISTING VERTICAL LADDER TO REMAIN.
10. EXISTING COMPRESSOR UNITS AND STEEL FRAME TO REMAIN - REMOVE EXISTING REFRIGERANT LINES, SUCTION LINES, AND LIQUID LINES (WITH ANGLE SUPPORTS) FOR NEW ROOF INSTALLATION.
11. REMOVE EXISTING GUTTER AND DOWN SPOUT.
12. REMOVE EXISTING CAULK AND RE-CAULK AROUND EXISTING OPENING THIS AREA. (SEE SHEET A1.5)
13. REMOVE EXISTING MASONRY GROUT THIS AREA - RE-INSTALL NEW MASONRY GROUT AS SPECIFIED, MATCH EXISTING GROUT COLOR. (SEE SHEET A1.5)
14. REMOVE EXISTING SCUPPER FLASHING AND STRAINER. CAP DOWNSPOUT BELOW ROOF LINE.
15. REMOVE EXISTING DOWNSPOUT AND CONDUCTOR HEAD. REMOVE DOWNSPOUT STRAPS FROM EXTERIOR WALL. CAP DOWNSPOUT AT TOP OF EXISTING SIDEWALK.
16. REMOVE EXISTING MASONRY FOR NEW THROUGH WALL SCUPPER.
17. EXISTING CURB TO REMAIN. EQUIPMENT SHALL REMAIN IN OPERATION DURING CONSTRUCTION. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AND THE OWNER IF ANY PART OF THE CURB IS DAMAGED AND REQUIRES REPLACEMENT. LAB EQUIPMENT EXHAUST SHALL BE DISCONNECTED AND RECONNECTED FOR ROOF MEMBRANE FLASHING AND CURB CAP FLASHING IN ONE WORKING DAY. THE DISCONNECTION SHALL BE COORDINATED WITH THE OWNER AT A MIN. OF 72 HOURS PRIOR TO THE WORK.
1a.
1. REFER TO SPECIFICATIONS SECTION 07 01 50.19 FOR ROOFING REMOVAL PROCEDURES.
2. REMOVE ONLY AS MUCH ROOFING IN ONE DAY AS CAN BE MADE WATERTIGHT IN THE SAME DAY (SEE TEMPORARY ROOFING MEMBRANE REQUIREMENT FOR ROOF SECTIONS: A, B, & C.)
3. NOTIFY THE ARCHITECT OF ANY DETERIORATED OR DAMAGED WOOD BLOCKING, NAILERS, OR CURBS THAT ARE NOT INDICATED IN THE DRAWINGS TO BE REMOVED. REMOVAL AND REPLACEMENT WILL BE ADDED TO THE CONTRACT VIA CHANGE ORDER.
4. NOTIFY THE ARCHITECT OF ANY DETERIORATED OR DAMAGED ROOF DECKING AND REPLACE AS DIRECTED - SEE UNIT PRICING AND UNIT-PRICE ALLOWANCE UNDER SPEC SECTION 01 22 00.
5. NOTIFY THE ARCHITECT OF ADDITIONAL MASONRY TUCK POINTING THAT IS REQUIRED. REMOVE AND REPLACE ADDITIONAL MORTAR JOINTS ONLY AS DIRECTED. SEE UNIT PRICING AND UNIT PRICE ALLOWANCE UNDER SPEC SECTION 01 22 00.
GENERAL NOTES:
401 W. CAPITOL, SUITE 402
LITTLE ROCK, AR
501-370-9207 501-370-9208 (FAX)
72201
CONSULTANTS:
ISSUE DATE
CONTENTS
SHEET NUMBER
PROJECT NUMBER
REVISIONS
7/3
1/2
02
0 2
:28:4
8 P
M
A1.5
PARTIAL EXTERIORELEVATIONS
1505Z
PR
INC
E C
EN
TE
R R
OO
F R
EP
LA
CE
ME
NT
UN
IVE
RS
ITY
OF
CE
NT
RA
L A
RK
AN
SA
S
201
DO
NA
GH
EY
AV
E,
CO
NW
AY
, A
R
1/8" = 1'-0"1
ROOF "C" & "D" REPOINTING ELEVATION
1/8" = 1'-0"2
ROOF "E" REPOINTING ELEVATION1/8" = 1'-0"
3ROOF "B" REPOINTING ELEVATION
1/8" = 1'-0"4
ROOF "C" REPOINTING ELEVATION
KEYNOTES - DEMO
07/31/2020
July 31, 2020
BELOW
BELOW
BELOW
BELOW
ROOF 'A'ROOF 'C'
ROOF 'B'
ROOF 'E'
ROOF 'G'
ROOF 'F'
ROOF 'D'
1/8
" / 1
'-0
"
1/8
" / 1
'-0
"1
/8"
/ 1
'-0
"
1/8" / 1'-0"
1/8" / 1'-0"
SLO
PE
DO
WN
SLO
PE
DO
WN
1
A2.2
_______
4
A2.2
_______
3
A2.2
_______
1
A2.3
_______
6
A2.2
_______
2
A2.2
_______
2
A2.3
_______
5
A2.3
_______
4
A2.3
_______
3
A2.3
_______
5
A2.2
_______
6
A2.3
_______
2
A1.4
_______4
A1.4
_______
1
A2.4
_______
2
A2.4
_______
3
A2.4
_______
4
A2.4
_______
5
A2.4
_______
1b
1
1b
1
1
1b
1
1a
1
2
2
11
INSTALL COLD APPLIED, TWO COMPONENT POLYURETHANE BASED RESIN WITH REINFORCING FLASHING
FLEECE - SYSTEM TO BE COMPATIBLE WITH TPO ROOF SURFACE
2
11
11
2
2
2
2
3
3
3
10
3
3
33
33
3
33
3
3
3
3
3
4
4
4
4
4 4
44
4
4
44
4
4
3
3
4
4
4
3
5
6
6
6
6
6
6
7
8
9 99 9 9 9
9 9 9 99 9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9 9
A1.5 1
A1.5 2
A1.5
3
A1.5
4A2.51
A2.5
2
A2.6 1
A2.6
2
6
9
PAINT EXISTING STRUCTURAL STEEL
VE
RIF
Y O
VE
RA
LL D
IME
NS
ION
AN
D S
LO
PE
OF
RO
OF
EX
IST
ING
LA
NE
Y-M
AN
ION
RO
OF
TO
RE
MA
IN
10
1/8
" / 1
'-0
"9
9
9
9
9
9
9
9
1/8" / 1'-0"
1/8" / 1'-0"
1/8
" / 1
'-0
"
1/8
" / 1
'-0
"1
/8"
/ 1
'-0
"
9
9
9
99
99
9
9
9
9
4
6
4 PILASTER
4
4 PILASTER
4 PILASTER
4 PILASTER
4 PILASTER
4 PILASTER
9
9
9
9
PROVIDE NEW FLASHING BOOT AT EXISTING COLUMN
PENETRATION
3
NEW TRENCH DRAIN (BELOW)
NEW TRENCH DRAIN (BELOW)
6
A2.4
_______
6
A1.4
_______
CRICKET AT ROOF CURB (TYP.)
REPLACE EXISTING CAP FLASHING
EXTEND PIPING A MIN. OF 12" ABOVE NEW COPING CAP
1. DIMENSIONS ON DRAWINGS ARE APPROXIMATE ONLY. FIELD VERIFY ALL DIMENSIONS, UNLESS OTHERWISE NOTED. DO NOT SCALE DRAWINGS - WRITTEN DIMENSIONS TAKE PRECEDENCE OVER GRAPHIC REPRESENTATIONS. DETAIL DIMENSIONS TAKE PRECEDANCE OVER PLANS AND ELEVATIONS.
2. ALL DIMENSION REVISIONS, MODIFICATIONS AND DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR REVIEW AND CLARIFICATION PRIOR TO THE INSTALLATION OF THE WORK.
3. ALL BLOCKING SHALL BE PRESSURE TREATED.
1. PROVIDE NEW 20 YEAR WARRANTY ADHERED TPO ROOF MEMBRANE OVER COVER BOARD OVER TAPERED POLYISO. ROOF INSUL., OVER 1 1/2" POLYISO. BASE LAYER ROOF INSUL. OVER TEMPORARY ROOF MEMBRANE OVER EXISTING WOOD ROOF DECK. SLOPE INSULATION PER DRAWINGS. NO SLOPE INDICATES AREAS WHERE THE EXISTING DECK PROVIDES SLOPE TO THE PERIMETER DRAINAGE SYSTEM. PRIME EXISTING WOOD DECK AND INSTALL SELF-ADHERED TEMPORARY ROOFING MEMBRANE. MECHANICALLY FASTEN BASE LAYER OF INSUL. OVER TEMPORARY ROOFING TO ROOF DECK PER SPECFICATIONS. ADHERE TAPERED INSUL. TO BASE LAYER OF INSUL. WITH ADHESIVE PER SPECIFICATIONS. ADHERE COVER BOARD TO TAPERED INSUL. WITH ADHESIVE PER SPECIFICATIONS. ADHERE TPO ROOFING MEMBRANE TO COVER BOARD WITH ADHESIVE PER SPECIFICATIONS AND ROOFING MANUFACTURER'S WRITTEN INSTRUCTIONS.
PROVIDE NEW 20 YEAR WARRANTY ADHERED TPO ROOF MEMBRANE OVER COVER BOARD OVER TAPERED POLYISO. ROOF INSUL., OVER 1 1/2" POLYISO. BASE LAYER ROOF INSUL. OVER EXISTING MTL ROOF DECK. SLOPE INSULATION PER DRAWINGS. NO SLOPE INDICATES AREAS WHERE THE EXISTING DECK PROVIDES SLOPE TO THE PERIMETER DRAINAGE SYSTEM. MECHANICALLY FASTEN BASE LAYER OF INSUL. TO MTL ROOF DECK PER SPECFICATIONS. ADHERE TAPERED INSUL. TO BASE LAYER OF INSUL. WITH ADHESIVE PER SPECIFICATIONS. ADHERE COVER BOARD TO TAPERED INSUL. WITH ADHESIVE PER SPECIFICATIONS. ADHERE TPO ROOFING MEMBRANE TO COVER BOARD WITH ADHESIVE PER SPECIFICATIONS AND ROOFING MANUFACTURER'S WRITTEN INSTRUCTIONS.
PROVIDE NEW 20 YEAR WARRANTY ADHERED TPO ROOF MEMBRANE OVER COVER BOARD OVER TAPERED POLYISO. ROOF INSUL., OVER 1 1/2" POLYISO. BASE LAYER ROOF INSUL. OVER EXISTING MTL ROOF DECK. SLOPE INSULATION PER DRAWINGS. NO SLOPE INDICATES AREAS WHERE THE EXISTING DECK PROVIDES SLOPE TO THE PERIMETER DRAINAGE SYSTEM. MECHANICALLY FASTEN BASE LAYER OF INSUL. TO WOOD DECK PER SPECFICATIONS. ADHERE TAPERED INSUL. TO BASE LAYER OF INSUL. WITH ADHESIVE PER SPECIFICATIONS. ADHERE COVER BOARD TO TAPERED INSUL. WITH ADHESIVE PER SPECIFICATIONS. ADHERE TPO ROOFING MEMBRANE TO COVER BOARD WITH ADHESIVE PER SPECIFICATIONS AND ROOFING MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. RE-INSTALL EXISTING EQUIPMENT AND PROVIDE NEW CURB TO MAINTAIN MIN. CLEARANCE ABOVE NEW ROOF MEMBRANE AS INDICATED.
3. PROVIDE NEW SCUPPER FLASHING AND TPO MANUFACTURER RECOMMENDED ROOF MEMBRANE TERMINATION.
4. PROVIDE NEW PRE-FINISHED METAL COPING OVER EXISTING PRE-CAST STONE COPING.
5. PROVIDE NEW GAS LINE ROUTING ABOVE - PROVIDE SUPPORTS AND SLEEPERS PER TPO MANUFACTURER RECOMMENDATIONS. INSTALL GAS LINE A MIN. OF 24" FROM EXTERIOR WALLS AND MIN. OF 6" ABOVE NEW PRE-FIN. METAL COPINGS.
6. NEW VENT THRU ROOF (VTR) FLASHING. SEE DETAIL 3 ON SHEET A2.4.
7. EXISTING COMPRESSOR UNITS AND STEEL FRAME -PROVIDE NEW ROUTING FOR REFRIGERANT LINES, SUCTION LINES, AND LIQUID LINES (WITH ANGLE SUPPORTS) AT NEW ROOF INSTALLATION.
8. PROVIDE NEW GUTTER AND DOWN SPOUT ON ROOF 'F'.
9. PROVIDE CRICKETING AS INDICATED - SLOPE ALL CRICKETS AT 1/4" PER FOOT.
10. PROVIDE NEW CUT IN SCUPPER, STRAINER, FLASHING,
11. RE-INSTALL EXISTING EQUIPMENT (SAME DAY AS DISCONNECT) AND FLASH OVER EXISTING CURB.
1a.
1b.
401 W. CAPITOL, SUITE 402
LITTLE ROCK, AR
501-370-9207 501-370-9208 (FAX)
72201
CONSULTANTS:
ISSUE DATE
CONTENTS
SHEET NUMBER
PROJECT NUMBER
REVISIONS
7/3
1/2
02
0 2
:31:4
1 P
M
A2.1
RENOVATION ROOFPLAN
1505Z
PR
INC
E C
EN
TE
R R
OO
F R
EP
LA
CE
ME
NT
UN
IVE
RS
ITY
OF
CE
NT
RA
L A
RK
AN
SA
S
201
DO
NA
GH
EY
AV
E,
CO
NW
AY
, A
R
N
1/8" = 1'-0"1
RENOVATION ROOF PLAN
RENOVATION NOTES
KEYNOTES - RENO
07/31/2020
July 31, 2020
1/2" COVER BOARD
BONDING ADHESIVE
TPO ROOF MEMBRANE
PRE-FINISHED METAL COPING COVER
PRESSURE TREATED WOOD 2x BLOCKING -
BOLT TO EXISTING PRECAST STONE COPING
GALVANIZED ANCHOR CLIPS
STAINLESS STEEL FASTENERS
EXISTING PRECAST STONE COPING TO REMAIN
EXTEND TPO ROOF MEMBRANE OVER THE COPING
RIG
ID
1 1
/2"
VA
RIE
S
TA
PE
RE
D
INSULATION BASE LAYER
TAPERED INSULATION -SEE RENOVATION PLAN
EDGE SEALANT
TPO ROOF MEMBRANE
1/2" COVER BOARD
HOT AIR WELD
SEAM FASTENING PLATE
2 6
PRESSURE TREATED WOOD BLOCKING
PROVIDE EXPANSION BOLT @ 48" O.C. MAX TO FASTEN NEW
WOOD BLOCKING TO EXISTING STONE COPING
EXISTING WOOD DECKING - PATCH DECK AS REQUIRED
PROVIDE #12 DECK SCREWS TO FASTEN NEW BLOCKING TO
EXISTING DECK - SPACE 24" O.C. MAX. EACH WAY -
COUNTERSINK SCREW
RIG
ID
1 1
/2"
INSULATION BASE LAYER
TAPERED INSULATION -SEE RENOVATION PLAN
EDGE SEALANT
TPO ROOF MEMBRANE
1/2" COVER BOARD
1/2" COVER BOARD
BONDING ADHESIVE
HOT AIR WELD
SEAM FASTENING PLATE
TPO ROOF MEMBRANE
PRE-FINISHED METAL COPING COVER
PRESSURE TREATED WOOD 2x BLOCKING
GALVANIZED ANCHOR CLIPS
STAINLESS STEEL FASTENERS
EXISTING PRECAST STONE COPING TO REMAIN
EXTEND TPO ROOF MEMBRANE
OVER THE COPING
PRESSURE TREATED WOOD BLOCKING
2 6
TY
P.
4 1
/2"
TY
P.
3 1
/2"
TEMPORARY ROOFING MEMBRANE
AS INDICATED ON ROOF RENOVATION
PLAN - TYP.
TEMPORARY ROOFING MEMBRANE
EXISTING WOOD DECKING - PATCH
DECK AS REQUIRED
PROVIDE #12 DECK SCREWS TO FASTEN NEW BLOCKING TO EXISTING DECK - SPACE 24" O.C. MAX. EACH WAY - COUNTERSINK SCREW
PROVIDE EXPANSION BOLT @ 48" O.C. MAX TO
FASTEN NEW WOOD BLOCKING TO EXISTING
STONE COPING
INSULATION BASE LAYER
TAPERED INSULATION CRICKET-SEE RENOVATION PLAN
EDGE SEALANT
TPO ROOF MEMBRANE
1/2" COVER BOARD
1/2" COVER BOARD
BONDING ADHESIVE
HOT AIR WELD
SEAM FASTENING PLATE
TPO ROOF MEMBRANE
PRE-FINISHED METAL COPING COVER
PRESSURE TREATED WOOD 2x BLOCKING - BOLT TO EXISTING PRECAST STONE COPING
GALVANIZED ANCHOR CLIPS
STAINLESS STEEL FASTENERS
EXISTING PRECAST STONE COPING TO REMAIN
EXTEND TPO ROOF MEMBRANE OVER THE
COPING
2 6
PRESSURE TREATED WOOD BLOCKING
RIG
ID
1 1
/2"
TY
P.
4 1
/2"
TY
P.
3 1
/2"
TEMPORARY ROOFING MEMBRANE
EXISTING WOOD DECKING - PATCH
DECK AS REQUIRED
PROVIDE #12 DECK SCREWS TO FASTEN NEW BLOCKING TO EXISTING DECK - SPACE 24" O.C. MAX. EACH WAY - COUNTERSINK SCREW
PROVIDE EXPANSION BOLT @ 48" O.C. MAX TO FASTEN NEW WOOD BLOCKING TO EXISTING STONE COPING
RIG
ID
1 1
/2"
INSULATION BASE LAYER
TAPERED INSULATION -SEE RENOVATION PLAN
EDGE SEALANT
TPO ROOF MEMBRANE
1/2" COVER BOARD
1/2" COVER BOARD
BONDING ADHESIVE
HOT AIR WELD
SEAM FASTENING PLATE
TPO ROOF MEMBRANE
PRE-FINISHED METAL COPING COVER
PRESSURE TREATED WOOD 2x BLOCKING -
BOLT TO EXISTING PRECAST STONE COPING
GALVANIZED ANCHOR CLIPS
STAINLESS STEEL FASTENERS
EXISTING PRECAST STONE COPING TO REMAIN
EXTEND TPO ROOF MEMBRANE OVER THE COPING
2 6
PRESSURE TREATED WOOD BLOCKING
TEMPORARY ROOFING MEMBRANE
EXISTING WOOD DECKING - PATCH DECK AS REQUIRED
PROVIDE #12 DECK SCREWS TO FASTEN NEW BLOCKING TO
EXISTING DECK - SPACE 24" O.C. MAX. EACH WAY -
COUNTERSINK SCREW
PROVIDE EXPANSION BOLT @ 48" O.C. MAX TO FASTEN NEW
WOOD BLOCKING TO EXISTING STONE COPING
RIG
ID
1 1
/2"
INSULATION BASE LAYER
TAPERED INSULATION -SEE RENOVATION PLAN
EDGE SEALANT
TPO ROOF MEMBRANE
1/2" COVER BOARD
1/2" COVER BOARD
BONDING ADHESIVE
HOT AIR WELD
SEAM FASTENING PLATE
TPO ROOF MEMBRANE
PRE-FINISHED METAL COPING COVER
PRESSURE TREATED WOOD 2x BLOCKING -
BOLT TO EXISTING PRECAST STONE COPING
GALVANIZED ANCHOR CLIPS
STAINLESS STEEL FASTENERS
EXISTING PRECAST STONE COPING TO REMAIN
EXTEND TPO ROOF MEMBRANE OVER THE COPING
2 6
PRESSURE TREATED WOOD BLOCKING
PROVIDE EXPANSION BOLT @ 48" O.C. MAX TO FASTEN NEW
WOOD BLOCKING TO EXISTING STONE COPING
EXISTING WOOD DECKING - PATCH DECK AS REQUIRED
PROVIDE #12 DECK SCREWS TO FASTEN NEW BLOCKING TO
EXISTING DECK - SPACE 24" O.C. MAX. EACH WAY -
COUNTERSINK SCREW
RIG
ID
1 1
/2"
INSULATION BASE LAYER
TAPERED INSULATION -SEE RENOVATION PLAN
EDGE SEALANT
TPO ROOF MEMBRANE
1/2" COVER BOARD
1/2" COVER BOARD
BONDING ADHESIVE
HOT AIR WELD
SEAM FASTENING PLATE
TPO ROOF MEMBRANE
PRE-FINISHED METAL COPING COVER
PRESSURE TREATED WOOD 2x BLOCKING -
BOLT TO EXISTING PRECAST STONE COPING
GALVANIZED ANCHOR CLIPS
STAINLESS STEEL FASTENERS
EXISTING PRECAST STONE COPING TO REMAIN
EXTEND TPO ROOF MEMBRANE OVER THE COPING
2 6
PRESSURE TREATED WOOD BLOCKING
PROVIDE EXPANSION BOLT @ 48" O.C. MAX TO FASTEN NEW WOOD
BLOCKING TO EXISTING STONE COPING
PROVIDE #12 SELF TAPPING SCREWS TO FASTEN BLOCKING
TO EXISTING METAL DECK -SPACE 24" O.C. MAX. EACH
WAY - COUNTERSINK SCREWS
EXISTING STEEL DECKING - PATCH DECK AS REQUIRED
401 W. CAPITOL, SUITE 402
LITTLE ROCK, AR
501-370-9207 501-370-9208 (FAX)
72201
CONSULTANTS:
ISSUE DATE
CONTENTS
SHEET NUMBER
PROJECT NUMBER
REVISIONS
7/3
1/2
02
0 2
:32:4
2 P
M
A2.2
ROOF EDGE DETAIL -RENOVATION
1505Z
PR
INC
E C
EN
TE
R R
OO
F R
EP
LA
CE
ME
NT
UN
IVE
RS
ITY
OF
CE
NT
RA
L A
RK
AN
SA
S
201
DO
NA
GH
EY
AV
E,
CO
NW
AY
, A
R
3" = 1'-0"5
ROOF E EDGE DETAIL - RENOVATION
3" = 1'-0"1
ROOF A EDGE DETAIL - RENOVATION3" = 1'-0"
2ROOF B EDGE DETAIL - RENOVATION
3" = 1'-0"3
ROOF C EDGE DETAIL - RENOVATION
3" = 1'-0"4
ROOF D EDGE DETAIL - RENOVATION3" = 1'-0"
6ROOF F EDGE DETAIL - RENOVATION
07/31/2020
July 31, 2020
EDGE SEALANT
NEW TPO ROOF MEMBRANE
NEW 1/2" COVER BOARD
HOT AIR WELD
2 6
NEW TWO-PIECE PRE-FABRICATED 24 GA. GALVANIZED METAL
COUNTERFLASHING - SET SURFACE MOUNTED REGLET IN SEALANT
NEW TPO ROOF MEMBRANE AND BONDING ADHESIVE
SEALANT
RAWL LITE SPIKE FASTENERS WITH NEOPRENE BACKED STAINLESS
STEEL WASHERS
NEW ROOF MEMBRANE TERMINATION BAR
NEW INSULATION BASE LAYER
NEW TAPERED INSULATION - SEE RENOVATION PLAN
EXISTING WOOD DECKING -PATCH DECK AS REQUIRED
NEW PRESSURE TREATED WOOD BLOCKING
SEAM FASTENING PLATE
MIN
.
6"
NEW TEMPORARY ROOFING MEMBRANE AS INDICATED ON
ROOF RENOVATION PLAN - TYP.
PROVIDE #12 DECK SCREWS TO FASTEN NEW BLOCKING TO
EXISTING DECK - SPACE 24" O.C. MAX. EACH WAY -
COUNTERSINK SCREW
EDGE SEALANT
TPO ROOF MEMBRANE
1/2" COVER BOARD
HOT AIR WELD
2 6
NEW TWO-PIECE PRE-FABRICATED 24 GA. GALVANIZED METAL COUNTERFLASHING - SET SURFACE MOUNTED REGLET IN SEALANT
TPO ROOF MEMBRANE AND BONDING ADHESIVE
SEALANT
RAWL LITE SPIKE FASTENERS WITH NEOPRENE BACKED STAINLESS STEEL WASHERS
ROOF MEMBRANE TERMINATION BAR
INSULATION BASE LAYER
TAPERED INSULATION -SEE RENOVATION PLAN
EXISTING WOOD DECKING -PATCH DECK AS REQUIRED
PRESSURE TREATED WOOD BLOCKING
SEAM FASTENING PLATE
TEMPORARY ROOFING MEMBRANE
PROVIDE #12 DECK SCREWS TO FASTEN NEW BLOCKING TO EXISTING DECK - SPACE 24" O.C. MAX. EACH WAY -COUNTERSINK SCREW
NEW TWO-PIECE PRE-FABRICATED 24 GA. GALVANIZED METAL COUNTERFLASHING -SET SURFACE MOUNTED REGLET IN SEALANT
SEALANT
RAWL LITE SPIKE FASTENERS WITH NEOPRENE BACKED STAINLESS STEEL WASHERS
EDGE SEALANT
TPO ROOF MEMBRANE
1/2" COVER BOARD
HOT AIR WELD
2 6
TPO ROOF MEMBRANE AND BONDING ADHESIVE
ROOF MEMBRANE TERMINATION BAR -ALIGN TO BOTTOM OF STONE COPING
INSULATION BASE LAYER
TAPERED INSULATION -SEE RENOVATION PLAN
EXISTING WOOD DECKING -PATCH DECK AS REQUIRED
PRESSURE TREATED WOOD BLOCKING
SEAM FASTENING PLATE
PROVIDE #12 DECK SCREWS TO FASTEN NEW BLOCKING TO EXISTING DECK - SPACE 24" O.C. MAX. EACH WAY -COUNTERSINK SCREW
EDGE SEALANT
TPO ROOF MEMBRANE
1/2" COVER BOARD
HOT AIR WELD
2 6
NEW TWO-PIECE PRE-FABRICATED 24 GA. GALVANIZED METAL COUNTERFLASHING - SET
SURFACE MOUNTED REGLET IN SEALANT
TPO ROOF MEMBRANE AND BONDING ADHESIVE
SEALANT
RAWL LITE SPIKE FASTENERS WITH NEOPRENE BACKED
STAINLESS STEEL WASHERS
ROOF MEMBRANE TERMINATION BAR - ALIGN TO
BOTTOM OF STONE COPING
INSULATION BASE LAYER
TAPERED INSULATION -SEE RENOVATION PLAN
EXISTING WOOD DECKING -PATCH DECK AS REQUIRED
PRESSURE TREATED WOOD BLOCKING
SEAM FASTENING PLATE
PROVIDE #12 DECK SCREWS TO FASTEN NEW BLOCKING TO EXISTING
DECK - SPACE 24" O.C. MAX. EACH WAY - COUNTERSINK SCREW
MIN.
2"
RIG
ID
1 1
/2"
6"
EDGE SEALANT
TPO ROOF MEMBRANE
1/2" COVER BOARD
HOT AIR WELD
TPO ROOF MEMBRANE AND BONDING ADHESIVE
SEAM FASTENING PLATE
PREFINISHED METAL DRIP EDGE
PRESSURE TREATED WOOD BLOCKING
CONT CLEAT FASTENED AT 6" O.C. WITH 1 1/4"
RING SHANK NAILS - TYP
EXIST. MASONRY WALL CONSTRUCTION - V.I.F.
TPO PRESSURE-SENSITIVE COVER STRIP
WITH TPO PRIMER
2 6
HOT AIR WELD
SEAM FASTENING PLATE
1/2" COVERBOARD
VE
RIF
Y D
IME
NS
ION
IN
FIE
LD
EXPANSION BOLT - FASTEN BLOCKING TO EXISTING WALL AT 24" O.C. MAX. -
COUNTERSINK BOLT HEAD
EXISTING EXTERIOR INSULATING FINISH SYSTEM TO REMAIN
EXISTING PRECAST STONE COPING
EXISTING WOOD DECKING - PATCH DECK AS REQUIRED
PRESSURE TREATED WOOD BLOCKING
INSULATION BASE LAYER
TAPERED INSULATION
TAPERED INSULATION AT CRICKET - SEE RENOVATION PLAN
EDGE SEALANT
TPO ROOF MEMBRANE OVER 1/2" COVERBOARD
HOT AIR WELD
TPO ROOF MEMBRANE AND BONDING ADHESIVE OVER 1/2" COVERBOARD
SEAM FASTENING PLATE
ROOF MEMBRANE TERMINATION BAR
2 6
TEMPORARY ROOFING MEMBRANE
PROVIDE #12 DECK SCREWS TO FASTEN NEW BLOCKING TO EXISTING DECK - SPACE 24" O.C. MAX. EACH WAY - COUNTERSINK SCREW
401 W. CAPITOL, SUITE 402
LITTLE ROCK, AR
501-370-9207 501-370-9208 (FAX)
72201
CONSULTANTS:
ISSUE DATE
CONTENTS
SHEET NUMBER
PROJECT NUMBER
REVISIONS
7/3
1/2
02
0 2
:33:2
1 P
M
A2.3
ROOF TRANSITIONDETAILS -RENOVATION
1505Z
PR
INC
E C
EN
TE
R R
OO
F R
EP
LA
CE
ME
NT
UN
IVE
RS
ITY
OF
CE
NT
RA
L A
RK
AN
SA
S
201
DO
NA
GH
EY
AV
E,
CO
NW
AY
, A
R
3" = 1'-0"1
ROOF "A" TO WALL TRANSITION - RENOVATION3" = 1'-0"
2ROOF "C" TO WALL TRANSITION - RENOVATION
3" = 1'-0"3
ROOF "G" TO WALL TRANSITION - RENOVATION
3" = 1'-0"4
ROOF "E" TO WALL TRANSITION - RENOVATION3" = 1'-0"
5ROOF "C" TO "D" TRANSITION - RENOVATION
3" = 1'-0"6
TRANSITION ROOF "C" TO ADDITION - RENOVATION
07/31/2020
July 31, 2020
PRE-FINISHED METAL COPING COVER
PRE-FINISHED SCUPPER FLASHING AT BOTTOM
AND SIDES OF SCUPPER OPENING - PROVIDE
FULLY WELDED SEAMS
EXISTING WOOD DECK TO REMAIN
NEW PRESSURE TREATED WOOD BLOCKING
NEW TAPERED INSULATION
NEW RIGID INSULATION BASE LAYER
CUT EDGE SEALANT
NEW PRESSURE-SENSITIVE FLASHING WITH TPO PRIMER
WATER CUT OFF MASTIC
NEW TPO ROOFING MEMBRANE OVER 1/2"
COVERBOARD
TEMPORARY ROOFING MEMBRANE AS INDICATED ON
ROOF RENOVATION PLAN - TYP.
EXTEND SCUPPER SIDEWALL FLASHING TO
TOP OF EXISTING STONE COPING
PROVIDE #12 DECK SCREWS TO FASTEN NEW BLOCKING TO EXISTING DECK - SPACE
24" O.C. MAX. EACH WAY -COUNTERSINK SCREW
EXISTING WOOD DECK TO REMAIN
EXISTING EXTERIOR MASONRY WALL TO REMAIN
EXISTING CONDUCTOR HEAD AND DOWNSPOUT TO
REMAIN
1/2" COVER BOARD
BONDING ADHESIVE
TPO ROOF MEMBRANE
PRE-FINISHED METAL COPING COVER
EXISTING PRECAST STONE COPING TO REMAIN
EXTEND TPO ROOF MEMBRANE OVER THE COPING
SEALANT
NEW PRESSURE-SENSITIVE FLASHING WITH TPO PRIMER
WATER CUT OFF MASTIC
NEW TPO ROOF MEMBRANE OVER 1/2" COVER BOARD
PRE-FINISHED SCUPPER FLASHING AT BOTTOM AND SIDES OF SCUPPER OPENING - PROVIDE FULLY WELDED SEAMS
SEALANT
SEALANT
SEALANT
WATER CUT OFF MASTIC
TEMPORARY ROOFING MEMBRANE
PROVIDE EXPANSION BOLT @ 48" O.C. MAX TO FASTEN NEW WOOD BLOCKING TO EXISTING STONE COPING
PROVIDE #12 DECK SCREWS TO FASTEN NEW BLOCKING TO EXISTING DECK - SPACE
24" O.C. MAX. EACH WAY -COUNTERSINK SCREW EXISTING WOOD DECKING TO REMAIN -
PATCH DECK AS REQUIRED
EXTEND ALL V.T.R.s AS REQUIRED TO PROVIDE A MIN. 8" CLEARANCE ABOVE NEW TPO ROOF MEMBRANE
HOT AIR WELD
NEW TPO ROOF MEMBRANE OVER 1/2" COVERBOARD
MIN
. C
LE
AR
8"
NEW 1 1/2" RIGID INSULATION BASE LAYER
NEW TAPERED INSULATION = SLOPE 1/8" PER FOOT
TEMPORARY ROOFING MEMBRANE
PROVIDE NEW STL PIPE SLEEVE OF SUFFICIENT LENGTH TO SLIDE
OVER EXISTING PIPE TO THE DECK AND EXTEND 8" MINIMUM ABOVE
THE NEW ROOFING MEMBRANE AS REQUIRED - FIELD VERIFY HEIGHT
EXIST. ROOFTOP EQUIPMENT - REMOVE TEMPORARILY TO INSTALL TPO MEMBRANE.
DISCONNECT/RECONNECT BY LICENSED ELECTRICIAN
FASTENERS AT 12" O.C. MAX
TPO MEMBRANE
BONDING ADHESIVE
NEW INSULATED ROOF CURB
FASTENER & SEAM FASTENING PLATE AT 12" O.C. MAX
1 1/2" MIN HOT AIR WELD
CUT EDGE SEALANT
NEW 1/2" COVER BOARD
NEW 1/8"/FT TAPERED ROOF INSUL
NEW 1 1/2" RIGID INSUL BASE LAYER
NEW 2x PRESSURE TREATED BLOCKING AS REQUIRED TO PROVIDE MIN. CLEARANCE ABOVE NEW ROOF MEMBRANE
EXISTING ROOF DECKING -REPAIR AS REQUIRED
FIELD VERIFY ALL CONDITIONS FOR OPENING DIMENSIONS
EXISTING OPENING TO REMAIN
TEMPORARY ROOFING MEMBRANE
PROVIDE 3/8" DIA. LAG SCREW TO FASTEN NEW BLOCKING - SPACE 24" O.C. MAX. EACH WAY - COUNTERSINK SCREW
PROVIDE #12 DECK SCREWS TO FASTEN NEW BLOCKING TO EXISTING DECK - SPACE 24" O.C. MAX. EACH WAY - COUNTERSINK SCREW
OVERSIZED CLOSED-CELL FOAM BACKER ROD
BONDING ADHESIVE
TPO ROOF MEMBRANE
NEW TAPERED INSULATION -SLOPE 1/8" PER FOOT
NEW 1 1/2" RIGID INSUL BASE LAYER
EXISTING ROOF DECKING - PATCH AS REQUIRED
1 1/2" MIN HOT AIR WELD
CUT EDGE SEALANT
NEW 2x PRESSURE TREATED BLOCKING AS REQUIRED TO PROVIDE MIN. CLEARANCE ABOVE NEW ROOF MEMBRANE
TPO ROOF MEMBRANE OVER 1/2" COVER BOARD
EXISTING ROOF HATCH -REINSTALL OVER NEW
WOOD BLOCKING - FLASH ALL SIDES AS INDICATED
MIN
.
1' -
0"
TEMPORARY ROOFING MEMBRANE
PROVIDE 3/8" DIA. LAG SCREW TO FASTEN NEW BLOCKING - SPACE 24" O.C. MAX. EACH WAY -COUNTERSINK SCREW
PROVIDE #12 DECK SCREWS TO FASTEN NEW BLOCKING TO EXISTING DECK - SPACE 24" O.C. MAX. EACH WAY - COUNTERSINK SCREW
TPO COVER STRIP WITH TPO PRIMER - EXTEND OVER TAPERED EDGE
STRIP
NEW 1 1/2" RIGID INSUL BASE LAYER
NEW 1/8"/FT TAPERED INSUL
NEW 1/2" COVER BOARD
NEW 2x6 P.T. PERIMETER BLOCKING - PROVIDE
ANCHOR BOLT ATTACHMENT AT 24" O.C. MAX.
NEW TAPERED EDGE STRIP
NEW PRE-FINISHED METAL EDGE FLASHING WITH A MIN. 3" FLANGE. FASTEN AT 3" O.C. WITH 1 1/4" RING SHANK NAILS - TYP
NEW PRE-FINISHED METAL GUTTER BRACKETS AT 24" O.C. MAX. - TYP AT ALL GUTTERS
CONT CLEAT FASTENED AT 6" O.C. WITH 1 1/4" RING SHANK NAILS - TYP
CUT EDGE SEALANT
NEW PRE-FINISHED METAL GUTTER (MATCH EXISTING FINISH) WITH 1" WIDE x 1/8" FLAT STOCK ALUM. BRACKETS AT 36" O.C. ATTACH WITH 2 DECK SCREWS PER BRACKET. RIVET BRACKET TO FRONT FACE OF GUTTER AND SEAL.
6"
5 1/4" 3/4"
1 1
/2"
PRE-FINISHED METAL GUTTER OUTLET - SET IN SEALANT -ATTACH PER MANUFACTURER SPECIFICATIONS
NEW 4" x 4" PRE-FINISHED METAL DOWNSPOUT (MATCH EXISTING FINISH) -EXTEND TO SPLASH BLOCK BELOW
NEW TEMPORARY ROOFING MEMBRANE
EXISTING METAL ROOF DECK
EXISTING BRICK MASONRY VENEER
EXISTING EXTERIOR STRUCTURAL WALL
PROVIDE EXPANSION BOLT @ 48" O.C. MAX TO FASTEN NEW WOOD BLOCKING TO EXISTING MASONRY WALL
401 W. CAPITOL, SUITE 402
LITTLE ROCK, AR
501-370-9207 501-370-9208 (FAX)
72201
CONSULTANTS:
ISSUE DATE
CONTENTS
SHEET NUMBER
PROJECT NUMBER
REVISIONS
7/3
1/2
02
0 2
:33:5
7 P
M
A2.4
ROOF DETAILS -RENOVATION
1505Z
PR
INC
E C
EN
TE
R R
OO
F R
EP
LA
CE
ME
NT
UN
IVE
RS
ITY
OF
CE
NT
RA
L A
RK
AN
SA
S
201
DO
NA
GH
EY
AV
E,
CO
NW
AY
, A
R
3" = 1'-0"1
SCUPPER DETAIL - OPEN COPING - RENOVATION3" = 1'-0"
2SCUPPER DETAIL - THROUGH WALL - RENOVATION
3" = 1'-0"3
TYP. VENT THROUGH ROOF - RENOVATION
3" = 1'-0"4
TYP. CURB DETAIL - RENOVATION3" = 1'-0"
5TYP. ROOF HATCH DETAIL - RENOVATION
3" = 1'-0"6
ROOF "F" GUTTER DETAIL - RENOVATION
07/31/2020
July 31, 2020
GROUND FLOOR
2ND FLOOR
12
' -
0"
1' -
2"
13
' -
6 3
/4"
9' -
10
"
EXISTING STONE COPING AND INSET
EXISTING VERTICAL ACCESS LADDER
EXISTING MASONRY BRICK
EXISTING STONE INSET
EXISTING MASONRY BRICK
EXISTING STONE COPING AND INSET
EXISTING MASONRY BRICK
EXISTING STONE INSET
EXISTING MASONRY BRICK
EXISTING WINDOW WITH STONE SILL - TYP.
EXISTING DOWNSPOUT WITH CONDUCTOR HEAD - TYP.
EXISTING MASONRY BRICK PILASTER - TYP.
EXISTING EXTERIOR GRADE - V.I.F.
14
' -
4"
1. PROTECT TREES AND SHRUBS IN THE LANDSCAPED AREAS AT THE EXTERIOR OF THE BUILDING DURING CONSTRUCTION TO PREVENT ANY DAMAGE OR DEATH TO THE TREES AND SHRUBS.
2. TUCK POINT AREAS INDICATED ON SHEET A1.53. PROVIDE SEALANT AT PERIMETER OF WINDOWS INDICATED ON SHEET A1.54. CLEAN ALL EXTERIOR BRICK MASONRY AND STONE PER SPEC SECTION 04 01 10.5. APPLY PENETRANT WATER REPELLENT OVER ENTIRE BUILDING FACADE PER
SPEC SECTION 07 19 23.
EXTERIOR WALL NOTES
EXISTING JOINTS IN STONE COPING AT APPROXIMATELY 48" O.C. - REMOVE ALL EXISTING VERTICAL JOINTS. REPLACE VERTICAL JOINT WITH BACKER ROD AND SEALANT (SEE SPECIFICATIONS) PRIOR TO INSTALLATION OF NEW STONE COPING METAL CAP.
GROUND FLOOR
2ND FLOOR
GYM FLOOR
EXISTING STONE COPING AND INSET
EXISTING MASONRY BRICK
EXISTING STONE INSET
EXISTING MASONRY BRICK
EXISTING WINDOW WITH STONE SILL - TYP.
EXISTING MASONRY BRICK PILASTER - TYP.
EXISTING EXTERIOR GRADE - V.I.F.
EXISTING STONE COPING AND INSET
EXISTING STONE PILASTER CAP - TYP.
EXISTING STONE INSET
EXISTING CONDUCTOR HEAD WITH DOWNSPOUT - TYP.
EXISTING OPEN SCUPPER - TYP.
EXISTING STONE INSET
EXISTING EXTERIOR EXHAUST LOUVER - TYP.
15
' -
4"2
2' -
0"
36
' - 1
0 3
/4"
40
' - 1
0 3
/4"
EXISTING EXTERIOR GRADE - V.I.F.
LANEY - MANION HALL ROOF
EXISTING PAINTED CONCRETE BASE
EXISTING PAINTED CONCRETE BASE
NEW PRE-FIN. METAL DOWNSPOUT AND CONDUCTOR HEAD - MATCH EXISTING FINISH
NEW PRE-FIN. METAL DOWNSPOUT AND CONDUCTOR HEAD - MATCH EXISTING FINISH
NOTE: NEW 8"x8" SCUPPER - SAW CUT INTO EXISTING MASONRY WALL - PROVIDE SCUPPER FLASHING SIMILAR TO DETAIL 2 ON A2.4
1. PROTECT TREES AND SHRUBS IN THE LANDSCAPED AREAS AT THE EXTERIOR OF THE BUILDING DURING CONSTRUCTION TO PREVENT ANY DAMAGE OR DEATH TO THE TREES AND SHRUBS.
2. TUCK POINT AREAS INDICATED ON SHEET A1.53. PROVIDE SEALANT AT PERIMETER OF WINDOWS INDICATED ON SHEET A1.54. CLEAN ALL EXTERIOR BRICK MASONRY AND STONE PER SPEC SECTION 04 01 10.5. APPLY PENETRANT WATER REPELLENT OVER ENTIRE BUILDING FACADE PER
SPEC SECTION 07 19 23.
EXTERIOR WALL NOTES EXISTING JOINTS IN STONE COPING AT APPROXIMATELY 48" O.C. -REMOVE ALL EXISTING VERTICAL JOINTS. REPLACE VERTICAL JOINT WITH BACKER ROD AND SEALANT (SEE SPECIFICATIONS) PRIOR TO INSTALLATION OF NEW STONE COPING METAL CAP.
401 W. CAPITOL, SUITE 402
LITTLE ROCK, AR
501-370-9207 501-370-9208 (FAX)
72201
CONSULTANTS:
ISSUE DATE
CONTENTS
SHEET NUMBER
PROJECT NUMBER
REVISIONS
7/3
1/2
02
0 2
:35:2
3 P
M
A2.5
EXTERIORELEVATIONS
1505Z
PR
INC
E C
EN
TE
R R
OO
F R
EP
LA
CE
ME
NT
UN
IVE
RS
ITY
OF
CE
NT
RA
L A
RK
AN
SA
S
201
DO
NA
GH
EY
AV
E,
CO
NW
AY
, A
R
1/8" = 1'-0"1
NORTH ELEVATION
1/8" = 1'-0"2
EAST ELEVATION
ADD ALTERNATE #1 - PROVIDE NEW SEALANT AROUND ALL EXISTING WINDOWS, LOUVERS, AND DOORS ALONG THE EXTERIOR FACADE NOT INDICATED ON SHEET A1.5
ADD ALTERNATE #1 - PROVIDE NEW SEALANT AROUND ALL EXISTING WINDOWS, LOUVERS, AND DOORS ALONG THE EXTERIOR FACADE NOT INDICATED ON SHEET A1.5
ALTERNATES:
ALTERNATES:
07/31/2020
July 31, 2020
07/31/2020
July 31, 2020
MECHANICAL FLOOR
POOL FLOOR
GROUND FLOOR
EXISTING STONE COPING AND INSET
EXISTING MASONRY BRICK
EXISTING STONE INSET
EXISTING MASONRY BRICK
EXISTING EXTERIOR GRADE - V.I.F.
EXISTING MASONRY BRICK
EXISTING STONE INSET
EXISTING MASONRY BRICK
EXISTING STONE INSET
EXISTING MASONRY BRICK
EXISTING STONE COPING AND INSET
LANEY-MANION BUILDING CONNECTION
EXISTING STONE COPING AND INSET
EXISTING CONDUCTOR HEAD AND DOWNSPOUT - TYP.
EXISTING STONE INSET
EXISTING MASONRY BRICK CHIMNEY
PAINTED CONCRETE BASE
EXISTING MASONRY BRICK
EXISTING MASONRY BRICK
EXISTING MASONRY BRICK
EXISTING STONE COPING AND INSET
EXISTING STONE INSET
EXISTING STONE COPING AND INSET
EXISTING STONE INSET
EXISTING MASONRY BRICK
19
' -
4"
29
' -
0"
25
' - 1
0"
18
' -
0"
1. PROTECT TREES AND SHRUBS IN THE LANDSCAPED AREAS AT THE EXTERIOR OF THE BUILDING DURING CONSTRUCTION TO PREVENT ANY DAMAGE OR DEATH TO THE TREES AND SHRUBS.
2. TUCK POINT AREAS INDICATED ON SHEET A1.53. PROVIDE SEALANT AT PERIMETER OF WINDOWS INDICATED ON SHEET A1.54. CLEAN ALL EXTERIOR BRICK MASONRY AND STONE PER SPEC SECTION 04 01 10.5. APPLY PENETRANT WATER REPELLENT OVER ENTIRE BUILDING FACADE PER
SPEC SECTION 07 19 23.
EXTERIOR WALL NOTES
EXISTING JOINTS IN STONE COPING AT APPROXIMATELY 48" O.C. - REMOVE ALL EXISTING VERTICAL JOINTS. REPLACE VERTICAL JOINT WITH BACKER ROD AND SEALANT (SEE SPECIFICATIONS) PRIOR TO INSTALLATION OF NEW STONE COPING METAL CAP.
EXISTING STONE COPING AND INSET
EXISTING MASONRY BRICK
EXISTING STONE INSET
EXISTING MASONRY BRICK
EXTERIOR GRADE - V.I.F.
EXISTING MASONRY BRICK
EXISTING STONE INSET
EXISTING MASONRY BRICK
EXISTING STONE INSET
EXISTING STONE COPING AND INSET
EXISTING CONDUCTOR HEAD AND DOWNSPOUT - TYP.
EXISTING PAINTED CONCRETE BASE
EXISTING EXTERIOR WINDOW WITH STONE SILL - TYP.
EXISTING STONE COPING AND INSET
EXISTING STONE INSET
EXISTING MASONRY BRICK
EXISTING PAINTED CONCRETE BASE
EXISTING MASONRY BRICK PILASTER - TYP.
PHYSICAL THERAPY CENTER BREEZEWAY
EXISTING STONE PILASTER CAP - TYP. EXISTING OPEN SCUPPER - TYP.
EXISTING STONE INSET
EXISTING MASONRY BRICK
EXISTING STONE COPING AND INSET
EXISTING MASONRY BRICK
EXISTING EXTERIOR GRADE - V.I.F.
NOTE: PROTECT TREES AND SHRUBS IN THE LANDSCAPED AREAS AT THE
EXTERIOR OF THE BUILDING DURING CONSTRUCTION TO PREVENT ANY DAMAGE
OR DEATH TO THE TREES AND SHRUBS.
1. PROTECT TREES AND SHRUBS IN THE LANDSCAPED AREAS AT THE EXTERIOR OF THE BUILDING DURING CONSTRUCTION TO PREVENT ANY DAMAGE OR DEATH TO THE TREES AND SHRUBS.
2. TUCK POINT AREAS INDICATED ON SHEET A1.53. PROVIDE SEALANT AT PERIMETER OF WINDOWS INDICATED ON SHEET A1.54. CLEAN ALL EXTERIOR BRICK MASONRY AND STONE PER SPEC SECTION 04 01 10.5. APPLY PENETRANT WATER REPELLENT OVER ENTIRE BUILDING FACADE PER
SPEC SECTION 07 19 23.
EXTERIOR WALL NOTES
EXISTING JOINTS IN STONE COPING AT APPROXIMATELY 48" O.C. -REMOVE ALL EXISTING VERTICAL JOINTS. REPLACE VERTICAL JOINT WITH BACKER ROD AND SEALANT (SEE SPECIFICATIONS) PRIOR TO INSTALLATION OF NEW STONE COPING METAL CAP.
EXISTING MASONRY BRICK CHIMNEY
EXISTING STONE INSET
401 W. CAPITOL, SUITE 402
LITTLE ROCK, AR
501-370-9207 501-370-9208 (FAX)
72201
CONSULTANTS:
ISSUE DATE
CONTENTS
SHEET NUMBER
PROJECT NUMBER
REVISIONS
7/3
1/2
02
0 2
:36:0
1 P
M
A2.6
EXTERIORELEVATIONS
1505Z
PR
INC
E C
EN
TE
R R
OO
F R
EP
LA
CE
ME
NT
UN
IVE
RS
ITY
OF
CE
NT
RA
L A
RK
AN
SA
S
201
DO
NA
GH
EY
AV
E,
CO
NW
AY
, A
R
1/8" = 1'-0"1
SOUTH ELEVATION
1/8" = 1'-0"2
WEST ELEVATION
ADD ALTERNATE #1 - PROVIDE NEW SEALANT AROUND ALL EXISTING WINDOWS, LOUVERS, AND DOORS ALONG THE EXTERIOR FACADE NOT INDICATED ON SHEET A1.5
ADD ALTERNATE #1 - PROVIDE NEW SEALANT AROUND ALL EXISTING WINDOWS, LOUVERS, AND DOORS ALONG THE EXTERIOR FACADE NOT INDICATED ON SHEET A1.5
ALTERNATES:
ALTERNATES:
07/31/2020
July 31, 2020
ROOF 'G' ROOF 'F'
NEW SIDEWALK
+/- 10' - 0" V.I.F.
NEW SIDEWALK
+/- 10' - 0" V.I.F.
PROVIDE DOWELS TO TIE NEW SIDEWALK INTO EXISTING SIDEWALK - SEE DETAIL 2 ON SHEET A2.7
EXISTING CONCRETE SIDEWALK
LOCATE DOWNSPOUT AND NEW CONCRETE SIDEWALK WITH LOCATION OF NEW
THROUGH WALL SCUPPERS - NEW 8" x 8" SCUPPERS - SAW CUT INTO EXISTING MASONRY WALL - PROVIDE SCUPPER
FLASHING SIMILAR TO DETAIL 2 ON A2.4 -EXTEND DOWN SPOUT TO DRAIN COVER -
HOLD DRAIN COVER BACK TO ALLOW DISCHARGE INTO NEW TRENCH DRAIN.
SLOPE TRENCH DRAIN AT SIDEWALK - EXTEND 4" CORRUGATED PIPE EXTENSION TO DAYLIGHT
CAP EXISTING DOWNSPOUT AT TOP OF
EXISTING SIDEWALK
LANEY-MANION ADDITION
(NOT IN CONTRACT)
CUT BACK EXISTING GRADING TO PROVIDE
POSITIVE DRAINAGE
2
A2.7
Sim
_______2
A2.7
Sim
_______
REPLACE SOD AT AREA WHERE REGRADING IS REQUIRED FOR POSITIVE DRAINAGE - SEE DETAIL 3 ON SHEET A2.7
PROVIDE 8" TURN DOWN AT NEW SIDEWALK EDGE - TYP.
PROVIDE 8" TURN DOWN AT NEW SIDEWALK EDGE - TYP.
CONCRETE EXPANSION JOINT (ALL SIDES - TYP)
CONCRETE EXPANSION JOINT (ALL SIDES - TYP)
E.J
.
E.J
.
C.J
.
C.J
.
E.J
.
E.J
.
NOTE: CONTRACTOR TO REPLACE ANY SODDED AREAS DAMAGED DURING CONSTRUCTION ALONG THE ENTIRE PERIMETER OF THE BUILDING
4"
TOP OF COMPACTED SUBGRADE
NEW SOD OVER TOPSOIL
3/4" +/-
LINE OF SAW CUT SIDEWALK
SELF-LEVELING JOINT SEALANT
CLOSED CELLBACKER ROD
EXP. JOINT MATERIAL
#3x24" DOWEL @ 18" O.C. IN AREAS INDICATED ON PLAN
GREASE DOWEL AT EXISTING CONCRETE
LINE OF SAW CUT SIDEWALK
GREASE DOWEL AT EXISTING CONCRETE
EXISTING CONCRETE SIDEWALK
EXISTING CONCRETE
CAST-IN-PLACE DRAIN SYSTEM WITH SOLID COVER GRATING (SLOPE FOR POSITIVE
DRAINAGE AWAY FROM THE BUILDING EXTERIOR) - CENTER TRENCH DRAIN AT
CENTERLINE OF NEW DOWNSPOUT
NEW CONCRETE SIDEWALK - MATCH EXISTING FINISH
+/- 10'-0" V.I.F.
4"
4" 4"
V.I.F.
401 W. CAPITOL, SUITE 402
LITTLE ROCK, AR
501-370-9207 501-370-9208 (FAX)
72201
CONSULTANTS:
ISSUE DATE
CONTENTS
SHEET NUMBER
PROJECT NUMBER
REVISIONS
7/3
1/2
02
0 2
:50:2
1 P
M
A2.7
MISCELLANEOUSDETAILS
1505Z
PR
INC
E C
EN
TE
R R
OO
F R
EP
LA
CE
ME
NT
UN
IVE
RS
ITY
OF
CE
NT
RA
L A
RK
AN
SA
S
201
DO
NA
GH
EY
AV
E,
CO
NW
AY
, A
R
N
1/4" = 1'-0"1
SITE PLAN - ROOF "G" NEW SCUPPER AND DOWNSPOUT1 1/2" = 1'-0"